Series WDS-SP-L, WDS-SP-R - Watts Water Technologies

image

Contents

1. Filetage a droite Veiller respecter tous les codes locaux lors de l installation de ce dispositif WWATTS Instructions d installation Couper l alimentation gaz du chauffe eau a b Couper l alimentation en eau du chauffe eau c Vidanger l eau du chauffe eau de sorte que la tuyauterie d alimentation en eau froide ne contienne plus d eau d Fermer le robinet de vidange apres avoir vidang l eau Fe WWATTS STATUS SILENCE OPEN A CLOSED gt yy Figure 1 Figure 2 Figure 3 1 Installer l unit de contr le sur la tuyauterie d alimentation en eau froide avec la fl che du robinet pointant dans la direction de l coulement vers le chauffe eau Figure 1 ATTENTION Ne pas chauffer directement le corps du robinet Braser l avance les raccords d adaptateur qui seront utilis s pour raccorder la tuyauterie au robinet Braser avec pr caution pour viter d endommager le couvercle du robinet et les composants internes 2 Apres avoir bras la tuyauterie aux raccords appliquer un produit d tanch it pour filetage sur les raccords des adaptateurs et visser les adaptateurs auxquels est attach e la tuyauterie dans le corps du robinet Figure 2 IMPORTANT Pour les chauffe eau gaz il est important de placer le robinet de sorte que le couvercle ne soit pas proximit imm diate de la tuyauterie de ventilation du carneau Figure 3 3 Installer et braser la tuyauterie l aliment
2. 50 pies de calibre 20 35 pies de calibre 22 Nota si se desea contar con detecci n de alarma remota la conexi n al circuito de alarma se puede realizar utilizando los contactos normalmente abiertos suministrados en la cinta terminal Estos contactos est n clasificados para 150 mA Si se excede este rango de amperaje se puede da ar la unidad de control La garant a se anular si se excede la corriente nominal Figura 13 110 VCA 12 VC D 4 12VCC Fuente de Cinta alimentaci n terminal Figura 11 Figura 12 Figura 13 IMPORTANTE no insertar la fuente de alimentaci n en la toma de 120 VCA hasta que se haya finalizado la instalaci n 6 Insertar el conector de la placa de circuito verde en la unidad de control Figura 14 7 Verificar la posici n del reinicio de la v lvula ubicado en la parte delantera de la unidad de control Las ranuras deben indicar que la v lvula se encuentra en la posici n abierta La posici n abierta es la posici n de las agujas del reloj cuando marcan las 11 en punto Figura 15 posici n abierta Figura 16 posici n cerrada 8 Abrir el suministro de agua y controlar que no haya fugas WIWATTS STATUS SILENCE WWATTS STATUS SILENCE OPEN CLOSED Figura 14 Figura 15 Figura 16 9 Insertar la fuente de alimentaci n en una toma adecuada de 120 VCA La luz de estado en la unidad de control debe ser verde IMPORTANTE la toma debe tener alimentaci n todo el tiempo
3. No debe controlarse mediante un interruptor 10 Encender la fuente de calor alimentaci n al calentador de agua El calentador de agua debe encenderse normalmente El piloto debe estar encendido en los calentadores de agua a gas con piloto permanente Probar el sistema antes de terminar la instalacion 1 Colocar suficiente agua en la bandeja de drenaje o en el dique de agua para accionar el cierre de detector de agua 2 Luego de accionarlo debe ocurrir lo siguiente a Se debe cortar inmediatamente la alimentaci n hacia el calentador de agua b Se debe cortar inmediatamente el suministro de agua hacia el calentador de agua La posici n del indicador de la v lvula en la unidad de control debe indicar que la v lvula se encuentra en la posici n cerrada La luz indicadora verde de la unidad de control debe volverse roja Debe sonar una alarma sonora y si est conectada la alarma remota debe accionarse La alarma sonora puede silenciarse presionando el bot n negro de silencio de la unidad de control 3 Si se generan todas las funciones anteriores se puede reiniciar la unidad 4 Asegurarse de que el piloto est encendido Para reiniciar la unidad de control 1 Retirar la almohadilla de detecci n de agua de la bandeja de drenaje o el dique de agua y secar la humedad de la placa de circuito verde Unidad de control Remover el agua de la bandeja de drenaje o el dique de agua Volver a colocar la almohadilla de de
4. d alimentation Figure 7 sur le chauffe eau comme indiqu Une fois l installation du module de coupure d alimentation termin e acheminer le c ble de connexion vers l unit de contr le et ins rer le connecteur de verrouillage dans la carte de circuit imprim Figure 7 Fonctionnement de la veilleuse permanente 1 Retirer le thermocouple du robinet de gaz Figure 8 2 Installer le module de coupure d alimentation fourni avec le robinet avec d tecteur d eau sur le robinet de gaz Figure 9 3 Installer le thermocouple sur le module de coupure d alimentation Figure 10 1 FU lA prn Figure 8 Figure 9 Figure 10 4 Retirer le bornier de la carte de circuit imprim verte de l unit de contr le en tirant tout droit dessus Figure 11 5 Proc der au c blage le fil est fourni par l installateur Du fil de thermostat est acceptable entre le connecteur de la carte de circuit imprim verte et lali mentation lectrique en respectant la polarit comme illustr sur le module d alimentation et le panneau de contr le vers et vers Figure 12 Longueur maximale du c ble du thermostat calibre 18 75 pieds calibre 20 50 pieds calibre 22 35 pieds Remarque Si une t l d tection de l alarme est souhait e la connexion au circuit d alarme peut tre r alis e en utilisant les contacts normalement ouverts disponibles sur le bornier Ces contacts sont class s pour une intensit de 150
5. de agua e incluye el rea en donde termina el tubo de drenaje de alivio de seguridad de temperatura y presi n b Instalar el conector de pl stico suministrado con el Dique de agua en los dos extremos del dique de agua de modo que no haya espacios entre los extremos Figura 6 y Figura 6a 5 Instalar el m dulo disyuntor de alimentaci n Figura 7 al calentador de agua tal como se indica Luego de finalizar la instalaci n del m dulo disyuntor de alimentaci n enviar el cable conector a la unidad de control e insertar el conector entrelazado a la placa de circuito Figura 7 Funcionamiento del piloto permanente 1 Retirar el termopar de la v lvula de gas Figura 8 2 Instalar el m dulo disyuntor de alimentaci n suministrado con el cierre de detector de agua a la v lvula de gas Figura 9 3 Instalar el termopar al m dulo disyuntor de alimentaci n Figura 10 4 H alli A prn Figura 8 Figura 9 E Figura 10 4 Retirar la cinta terminal de la placa de circuito verde de la unidad de control tirando directamente de la cinta terminal Figura 11 5 Instalar el cableado El cable es suministrado por el instalador Se puede usar cable de termostato entre el conector de la placa de circuito verde y la fuente de alimentaci n teniendo en cuenta la polaridad tal como se muestra en la fuente de alimentaci n y en el panel de control a y a Figura 12 Longitud m xima del cable de termostato 75 pies de calibre 18
6. mA Ne pas d passer cette gamme d intensit au risque d endommager l unit de contr le Le d passement du courant nominal annulera la garantie Figure 13 Alimentation Bornier lectrique Figure 11 Figure 12 Figure 13 IMPORTANT Ne pas brancher l alimentation lectrique dans la prise de 120 V c a avant d avoir termin l installation 6 Ins rer le connecteur de la carte de circuit imprim verte dans l unit de contr le Figure 14 7 V rifier la position de r initialisation du robinet situ e l avant de l unit de contr le Les encoches doivent indiquer que le robinet est en position ouverte La position 11 heures correspond la position ouverte Figure 15 position ouverte Figure 16 position ferm e 8 Ouvrir l alimentation d eau et rechercher toute fuite 9 Brancher l alimentation lectrique dans une prise de 120 V c a adapt e Le voyant d tat de l unit de contr le est vert wWWATTS STATUS SILENCE WWATTS STATUS SILENCE OPEN CLOSED Figure 14 Figure 15 Figure 16 IMPORTANT La prise lectrique doit toujours tre sous tension elle ne doit pas tre contr l e par un commutateur 10 Ouvrir activer la source de chauffage lectricit du chauffe eau Le chauffe eau doit fonctionner normalement Pour les chauffe eau gaz veilleuse permanente la veilleuse doit tre allum e 3 Tester le systeme avant de quitter le site 1 Mettre suffisamment d eau dans le b
7. requiere el cableado del termostato que debe ser suministrado por el instalador Planificaci n de su instalaci n El cierre de detector de agua debe instalarse de 6 a 12 pulgadas del calentador de agua en el tubo de suministro de entrada de agua fr a La unidad de control que aloja el sistema de circuitos para el funcionamiento de la v lvula tiene conectores entrelazados para la almohadilla de detecci n de agua la fuente de alimentaci n y la alarma remota y el m dulo disyuntor de alimentaci n Los cables suministrados no se deben cortar ni extender por lo que no se recomienda la instalaci n remota La almohadilla de detecci n de agua suministrada con el cierre de detector de agua debe colocarse tan cerca del calentador de agua como sea posible No es necesario retirar la cubierta de la unidad de control para instalar los cables de interconexi n Superficie de los suelos Suelos de tierra se debe colocar una bandeja de drenaje de metal o pl stico por debajo del calentador de agua Colocar la almohadilla de detecci n de agua dentro de la bandeja de drenaje Piso de cemento instalar el dique de agua suministrado con el juego de instalaci n del cierre de detector de agua alrededor del di metro externo del calentador de agua Colocar la almohadilla de detecci n de agua dentro del dique de agua Instalaci n en ticos se debe instalar una bandeja de drenaje de metal o pl stico por debajo del calentador de agua Colocar la almohadi
8. Series WDS SP L WDS SP R us FloodSafe Water Detector Shutoff Sizes and 1 20 and 25mm Please read all instructions identify all components and read all warnings prior to beginning the installation of this product This product is intended to prevent catastrophic water damage in the event of a water heater leak Please Note During an emergency operating condition the temperature and pressure relief valve installed on your water heater can discharge an excessive amount of water It is designed to protect your home or business from the potential danger of explosion Upon detection of this discharged water the FloodSafe Water Detector Shutoff shuts off both the supply of water and the source of power gas oil or electricity to the water heater preventing a very dangerous situation The FloodSafe Water Detector Shutoff also contains an audible amp visual alarm and contacts for monitored alarm systems It is a reset table device and can be tested at any time to ensure proper operation Parts Included Control Unit Power Cutout Module Power Supply WWATTS Water Detector Pad Pocket Screwdriver Water Dam Important Note Thermostat wiring is required and must be supplied by the installer Planning Your Installation The Water Detector Shutoff should be installed within 6 to 12 inches of the water heater on the cold water inlet supply pipe The Control Unit which houses the circuitry for the operation of the valve c
9. ac de r cup ration ou la barri re hydraulique pour activer le dispositif d arr t avec d tecteur d eau 2 Lors de l activation les v nements suivants surviennent a L alimentation lectrique du chauffe eau doit tre imm diatement coup e b L alimentation en eau du chauffe eau doit tre imm diatement coup e L indicateur de position du robinet sur l unit de contr le doit indiquer que le robinet est en position ferm e Le t moin vert de l unit de contr le doit passer au rouge Une alarme sonore doit retentir et le cas ch ant l alarme a distance doit tre activ e L alarme sonore peut tre mise en sourdine en appuyant sur le bouton de sourdine noir de l unit de contr le 3 Si toutes les fonctions pr c dentes se r alisent l unit peut tre r initialis e 4 S assurer que la veilleuse est allum e Unit de Pour r initialiser l unit de contr le contr le 1 Retirer la plaquette du d tecteur d eau du bac de r cup ration ou de la barri re hydraulique et essuyer l humidit de la carte de circuit imprim verte Essuyer toute eau du bac de r cup ration ou de la barri re hydraulique Replacer la plaquette du d tecteur d eau sur le sol ou dans le bac de r cup ration Alimentation lectrique 4 Mettre l indicateur de position du robinet sur l unit de contr le en position ouverte 5 S assurer que la veilleuse est allum e Le dispositif d arr t
10. age Note Temporary loss of power to the control unit will not cause the pilot to be extinguished The control unit will Keep the pilot on for up to 8 hours The Floodsafe Water Detector Shutoff will not operate as intended without power A battery back up is available to allow operation for 36 to 48 hours in the event of a power outage CALIFORNIA PROPOSITION 65 WARNING WARNING This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm California law requires this warning to be given to customers in the State of California For more information www watts com prop65 Limited Warranty Watts Regulator Co the Company warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment In the event of such defects within the warranty period the Company will at its option replace or recondition the product without charge THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT THE COMPANY MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE The remedy described in the first paragraph of this warranty shall constitute t
11. ation et l arriv e du chauffe eau o Figure 4 Figure 5 Figure 6 Figure 6a 4 Installer la plaquette du d tecteur d eau sous le chauffe eau avec la carte de circuit imprim verte en bas La plaquette du d tecteur doit reposer plat sur le sol ou dans le bac de r cup ration Acheminer le c ble de connexion vers l unit de contr le et ins rer le connecteur de verrouillage dans la carte de circuit imprim Figure 4 Remarque n est pas n cessaire de retirer le couvercle de l unit de contr le pour installer les c bles d interconnexion Pour retirer le c ble d intercon nexion utiliser le tournevis de poche fourni pour appuyer sur la languette du c ble tout en tirant ce dernier de sa prise Figure 5 Important Les fils d interconnexion ne doivent pas toucher ou se trouver proximit imm diate d une flamme ou d une surface chaude a En l absence d un bac de r cup ration installer la barri re hydraulique autour du p rim tre du chauffe eau La barri re hydraulique peut tre coup e afin de s adapter environ 1 ou 2 pouces l ext rieur du diam tre du chauffe eau et inclure la zone dans laquelle le tube de la soupape de d charge et de s curit thermique se termine b Installer le raccord en plastique fourni avec la barri re hydraulique aux deux extr mit s de la barri re afin de supprimer tout cart entre les deux extr mit s Figure 6 et Figure 6a 5 Installer le module de coupure
12. avec d tecteur d eau est pr sent configur pour fonc tionner en cas de fuite du chauffe eau Remarque Une perte temporaire d alimentation au niveau de l unit de contr le ne causera pas l extinction de la veilleuse L unit de contr le maintiendra la veilleuse allum pendant une dur e maximale de 8 heures Le dispositif d arr t avec d tecteur d eau Floodsafe ne fonctionnera pas sans alimentation lectrique Une batterie de secours est disponible pour permettre un fonctionnement pendant 36 48 heures en cas de panne d lectricit AVERTISSEMENT SUR LA PROPOSITION 65 DE LA CALIFORNIE AVERTISSEMENT Ce produit contient des produits chimiques reconnus par l tat de Californie comme tant NI E Barriere hydraulique Plaquette du d tecteur d eau canc rig nes et pouvant causer des malformations cong nitales et d autres dommages au syst me reproducteur La loi californienne exige que cet avertissement soit fourni a tous les clients de l tat de la Californie Pour obtenir plus d informations www watts com prop65 Garantie limit e Watts Regulator Co la Soci t garantit que chacun de ses produits est exempt de vice de mat riau et de fabrication dans des conditions normales d utilisation pour une p riode d un an compter de la date d exp dition d origine Dans l ventualit o de tels vices se manifesteraient pendant la p riode de garantie la Soci t sa
13. cours la soupape de d charge et de s curit thermique install e sur le chauffe eau peut lib rer une quantit d eau excessive Elle est concue pour prot ger une r sidence ou une entreprise du danger d explosion potentiel A la d tection de cette eau lib r e le dispositif d arr t d tecteur d eau FloodSafe coupe l alimentation en eau et la source d nergie gaz mazout ou lectricit du chauffe eau en vitant ainsi une situation tres dangereuse Le dispositif d arr t a d tecteur d eau FloodSafe inclut aussi une alarme sonore et visuelle et des contacts pour des systemes d alarme sous surveillance peut tre r initialis et test a tout moment pour garantir un fonctionnement correct Pieces incluses Unite de contr le Module de coupure d alimentation Alimentation lectrique GALA Y IA WIWATTS Plaquette du d tecteur d eau Tournevis de poche Barri re hydraulique Remarque importante Le c blage du thermostat est requis et doit tre fourni par l installateur Planification de l installation Le dispositif d arr t avec d tecteur d eau doit tre install entre 6 et 12 pouces du chauffe eau sur le tuyau d alimentation en eau froide L unit de contr le qui abrite le circuit permettant le fonctionnement du robinet contient des connecteurs de verrouillage pour la plaquette du d tecteur d eau l alimentation lectrique et l alarme distance ainsi que le module de coup
14. discr tion remplacera ou reconditionnera le produit sans frais LA PR SENTE GARANTIE EST EXPRESSE ET REPR SENTE LA SEULE GARANTIE OFFERTE PAR LA SOCI T POUR CE PRODUIT LA SOCI T N OFFRE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE PAR LA PRESENTE LA SOCIETE REJETTE SPECIFIQUEMENT TOUTE AUTRE GARANTIE EXPRESSE OU TACITE NOTAMMENT TOUTE GARANTIE TACITE DE QUALITE MARCHANDE OU D ADAPTATION A UN BUT PARTICULIER Le recours d crit dans le premier paragraphe de cette garantie constitue le seul recours toute violation de la pr sente garantie La Soci t ne saurait tre tenue responsable de tout dommage accessoire sp cial ou indirect y compris de fa on non limitative la perte de profits ou le co t aff rent la r paration ou au remplacement d autres biens qui seraient endommag s par suite du fonctionnement incorrect dudit produit d autres co ts r sultant de frais de main d uvre de retards de vandalisme de n gligence d une obstruction caus e par des mat riaux trangers de dommages caus s par une eau impropre des produits chimiques ou par tout autre v nement chappant au contr le de la Soci t La pr sente garantie est d clar e nulle et non avenue en cas d usage abusif ou incorrect d application d installation ou d entretien incorrects ou de modification du produit Certains Etats n autorisent pas les limitations de dur e d une garantie tacite ou l exclusion ou la limitation des dommages accessoires ou i
15. e water supply to the water heater c Drain water from the water heater so that the cold water supply piping is free of water d Close the drain valve after draining water y e WWATTS STATUS SILENCE OPEN y CLOSED gt yy Figure 1 Figure 2 Figure 3 1 Install the Control Unit on the cold water supply piping with the arrow on the valve pointing toward the direction of flow towards the water heater Figure 1 CAUTION Do not apply heat directly to the valve body Pre solder the adapter fittings that will be used to connect piping to the valve Use caution when soldering to avoid damage to the valve cover and internal components 2 After soldering the piping to the fittings apply thread sealant to the adapter fittings and thread the adapters with attached piping into the valve body Figure 2 IMPORTANT For gas water heaters it is important to position the valve so that the cover is not in close proximity to the flue vent pip ing Figure 3 3 Install and solder the piping to the supply and to the inlet of the water heater Er A Figure 4 Figure 5 Figure 6 Figure Ga 4 Install the Water Detector Pad under the water heater with the green circuit board down The Detector Pad must lie flat on the floor or in a drain pan Route the connecting cable to the Control Unit and insert the interlocking connector to the circuit board Figure 4 Note It is not necessary to remove the cover of the Control Unit to install
16. en limitaciones en la duraci n de una garant a impl cita y algunos Estados no permiten la exclusi n o limitaci n de da os accidentales o indirectos Por lo tanto es posible que las limitaciones anteriores no sean aplicables en su caso Esta garant a limitada le da derechos legales espec ficos usted podr a tener tambi n otros derechos que var an seg n el Estado Usted debe consultar las leyes estatales aplicables para determinar sus derechos EN LA MEDIDA EN QUE SEA CONGRUENTE CON LAS LEYES ESTATALES APLICABLES CUALQUIER GARANT A IMPL CITA QUE NO SEA RECHAZADA INCLUYENDO LAS GARANT AS IMPL CITAS DE APTITUD PARA LA COMERCIALIZACI N E IDONEIDAD PARA UN PROP SITO EN PARTICULAR SE LIMITA EN SU DURACI N A UN A O A PARTIR DE LA FECHA DEL EMBARQUE ORIGINAL WWATTS n Productos de control de caudal y seguridad del agua EE UU 815 Chestnut St No Andover MA 01845 6098 www watts com Canada 5435 North Service Rd Burlington ONT L7L 5H7 www wattscanada ca IS WDS SP 0841 EDP N 1915995 O Watts 2008 S ries WDS SP L WDS SP R S WDS SP Dispositif d arr t d tecteur d eau FloodSafe Dimensions 3 4 in et 1 in 20 et 25 mm Lire toutes les instructions identifier tous les composants et lire toutes les mises en garde avant de commencer l installation de ce produit Ce produit est destin a emp cher les d g ts d eau catastrophiques en cas de fuite d un chauffe eau Remarque En tat de fonctionnement de se
17. he sole and exclusive remedy for breach of warranty and the Company shall not be responsible for any incidental special or consequential damages including without limitation lost profits or the cost of repairing or replacing other property which is damaged if this product does not work properly other costs resulting from labor charges delays vandalism negligence fouling caused by foreign material damage from adverse water conditions chemical or any other circumstances over which the Company has no control This warranty shall be invalidated by any abuse misuse misapplication improper installation or improper maintenance or alteration of the product Some States do not allow limitations on how long an implied warranty lasts and some States do not allow the exclusion or limitation of incidental or consequential damages Therefore the above limitations may not apply to you This Limited Warranty gives you specific legal rights and you may have other rights that vary from State to State You should consult applicable state laws to determine your rights SO FAR AS IS CONSISTENT WITH APPLICABLE STATE LAW ANY IMPLIED WARRANTIES THAT MAY NOT BE DISCLAIMED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT WWATTS a Water Safety amp Flow Control Products USA 815 Chestnut St No Andover MA 01845 6098 www watts com Canada 5435 North Ser
18. lla de detecci n de agua dentro de la bandeja de drenaje V lvulas de gas con piloto permanente los termopares utilizados por algunos fabricantes de v lvulas de gas tienen una rosca hacia la izquierda en lugar de la rosca hacia la derecha m s com n Watts tiene modelos para cada dise o Asegurarse de tener el modelo correcto antes de comenzar la instalaci n Modelos WDS SP L rosca hacia la izquierda WDS SP R rosca hacia la derecha Asegurarse de cumplir con todos los c digos locales al instalar este dispositivo WWATTS Instrucciones de instalacion a Apagar toda la alimentacion gas hacia el calentador de agua b Cerrar el suministro de agua hacia el calentador de agua c Drenar el agua del calentador de agua de modo que el tubo de suministro de agua fr a no contenga agua d Cerrar la v lvula de drenaje luego de drenar el agua WWATTS STATUS SILENCE OPEN eo CLOSED gt yy Figura 1 Figura 2 Figura 3 1 Instalar la unidad de control en el tubo de suministro de agua fr a con la flecha de la v lvula apuntando en la direcci n del caudal hacia el calentador de agua Figura 1 PRECAUCI N no aplicar calor en forma directa al cuerpo de la v lvula Pre soldar las conexiones del adaptador que se utilizar n para conectar el tubo a la v lvula Tener cuidado al soldar a fin de evitar da ar la cubierta de la v lvula y los componentes internos 2 Luego de soldar el tubo a los ada
19. ndirects Les limitations susmentionn es peuvent donc ne pas s appliquer vous Cette garantie limit e vous donne des droits sp cifiques et il se peut que vous ayez aussi d autres droits qui varient d un Etat l autre Veuillez vous r f rer aux lois applicables de l tat pour d terminer vos droits en la mati re DANS LA MESURE PERMISE PAR LA LOI APPLICABLE DE L TAT TOUTES LES GARANTIES TACITES NE POUVANT PAS ETRE REJETEES Y COMPRIS LES GARANTIES TACITES DE QUALITE MARCHANDE ET D ADAPTATION A UN BUT PARTICULIER SONT LIMIT ES QUANT A LEUR DUREE A UN AN COMPTER DE LA DATE D EXPEDITION D ORIGINE e19001 2000 Produits de r gularisation de l eau et de s ret tats Unis 815 Chestnut St No Andover MA 01845 6098 www watts com Canada 5435 North Service Rd Burlington ONT L7L 5H7 www wattscanada ca IS WDS SP 0841 N EDP 1915995 Watts 2008
20. ntren tales defectos dentro del per odo de garant a la Compa a reemplazar o reacondicionar a su elecci n el producto sin costo alguno LA GARANT A AQU ESTIPULADA SE OTORGA EN FORMA EXPRESA Y ES LA NICA GARANT A OTORGADA POR LA COMPA A EN RELACI N CON EL PRODUCTO LA COMPA A NO OTORGA NINGUNA OTRA GARANT A YA SEA EXPRESA O IMPL CITA LA COMPA A POR LA PRESENTE RENUNCIA ESPEC FICAMENTE A TODAS LAS DEM S GARANT AS EXPRESAS O IMPL CITAS INCLUYENDO SIN LIMITACI N LAS GARANT AS IMPL CITAS DE APTITUD PARA LA COMERCIALIZACI N E IDONEIDAD PARA UN PROP SITO EN PARTICULAR La soluci n descrita en el primer p rrafo de esta garant a constituir la nica y exclusiva soluci n por incumplimiento de garant a y la Compa a no se har responsable por da os accidentales especiales o indirectos incluyendo sin limitaci n la p rdida de ganancias o el costo de reparaci n o reemplazo de otra propiedad que resulte da ada por el mal funcionamiento de este producto otros costos resultantes por mano de obra retardos vandalismo negligencia obstrucciones ocasionadas por materiales extra os da os debidos a condiciones adversas del agua qu micos o cualquier otra circunstancia sobre la cual la Compa a no tenga control Esta garant a no tendr validez en cualquier caso de abuso uso indebido aplicaci n incorrecta instalaci n inadecuada o mantenimiento adecuado o alteraci n del producto Algunos Estados no permit
21. ontains interlocking connectors for the Water Detector Pad the Power Supply and remote alarm and the Power Cutout Module The cables provided should not be cut or extended therefore remote installation is not recommended The Water Detector Pad supplied with the Water Detector Shutoff should be located as close to the water heater as possible It is not necessary to remove the cover of the Control Unit to install the interconnecting cables Flooring Surface Dirt flooring A metal or plastic drain pan must be installed under the water heater Position the Water Detector Pad inside the drain pan Cement floor Install the Water Dam provided with the Water Detector Shutoff installation kit around the outside diameter of the water heater Position the Water Detector Pad inside the Water Dam Attic installation A metal or plastic drain pan must be installed under the water heater Position Water Detector Pad inside the drain pan Standing Pilot Gas Valves Thermocouples used on some manufactures gas valves use a left hand thread instead of the more common right hand thread Watts has models for each design Check to be certain that you have the correct model before beginning your installation WWWATTS Models WDS SP L Left hand thread WDS SP R Right hand thread Please be certain to follow all local codes when installing this device Installation Instructions a Turn off all gas power to the water heater b Turn off th
22. pplied Thermostat wire is acceptable between the green circuit board connector and the Power Supply observing polarity as shown on both the Power Supply and the control panel to and to Figure 12 Maximum run of thermostat wire 18 gauge 75 feet 20 gauge 50 feet 22 gauge 35 feet Note If remote alarm detection is desired connection to the alarm circuit can be made using the normally open contacts provided on the terminal strip These contacts are rated for 150mA Do not exceed this amp range or damage to the Control Unit can occur Exceeding the current rating will void the warranty Figure 13 D 7 110 VAC A AN D PU de 12 VDC Power Terminal Supply Strip Figure 11 Figure 12 Figure 13 IMPORTANT Do not insert the Power Supply into the 120 VAC outlet until the installation is complete 6 Insert the green circuit board connector into the Control Unit Figure 14 7 Check the position of the valve reset located on the front of the Control Unit The slots should indicate the valve is in the open posi tion The 11 o clock position is the open position Figure 15 open position Figure 16 closed position 8 Turn on the water supply and check for leaks 9 Insert the Power Supply into a suitable 120 VAC outlet The status lamp on the Control Unit will be green WWATTS STATUS SILENCE WWATTS STATUS SILENCE OPEN CLOSED Figure 14 Figure 15 Figure 16 IMPORTANT The outlet must be powe
23. ptadores aplicar sellador para roscas a los adaptadores y ensartar los adaptadores con el tubo conectado en el cuerpo de la v lvula Figura 2 IMPORTANTE para los calentadores de agua a gas es importante colocar la v lvula en una posici n de modo que la cubierta no est demasiado cerca de la tuber a de ventilaci n de combusti n Figura 3 3 Instalar y soldar el tubo al suministro y a la entrada del calentador de agua Figura 4 Figura 5 Figura 6 o Figura 6a 4 Instalar la almohadilla de detecci n de agua debajo del calentador de agua con la placa de circuito verde hacia abajo La Almohadilla de detecci n debe estar en posici n horizontal sobre el piso o en una bandeja de drenaje Direccionar el cable conector a la unidad de control e insertar el conector entrelazado en la placa de circuito Figura 4 Nota no es necesario retirar la cubierta de la unidad de control para instalar los cables de interconexi n Para extraer un cable entrelazado usar el destornillador de bolsillo suministrado para presionar la leng eta del cable mientras se tira del cable para retirarlo de su toma Figura 5 Importante Los cables de interconexi n no deben tocar ni estar cerca de cualquier superficie caliente o llamas a Sino hay una bandeja de drenaje instalar el dique de agua alrededor del per metro del calentador de agua El Dique de agua puede cortarse para que encaje aproximadamente 1 a 2 pulgadas por fuera del di metro del calentador
24. red at all times it must not be controlled by a switch 10 Turn on the source of heat power to the water heater The water heater should fire normally For Standing Pilot Gas water heaters the pilot must be lit Test the System Prior to Leaving the Installation 1 Place enough water in the drain pan or Water Dam to actuate the Water Detector Shutoff 2 Upon actuation the following should take place a Power to the water heater should shut off immediately b The water supply to the water heater should shut off immediately The valve position indicator on the Control Unit should indicate that the valve is in the closed position The green indicating lamp on the Control Unit should turn to red d An audible alarm should sound and if connected the remote alarm should be actuated The audible alarm can be silenced by oressing the black silence button on the Control Unit 3 If all of the above functions take place the unit can be reset 4 Ensure the pilot is lit To Reset the Control Unit 1 Remove the Water Detector Pad from the drain pan or Water Dam and wipe the moisture from the green Circuit Board Control Wipe any water from the drain pan or Water Dam Reposition the Water Detector Pad on the floor or in the drain pan 4 Turn the valve position indicator on the Control Unit to the open position 5 Ensure the pilot is lit The Water Detector Shutoff is now set to operate in the event of water heater leak
25. tecci n de agua en el piso o en la bandeja de drenaje Fuente de alimentaci n 4 Llevar el indicador de posici n de la v lvula en la unidad de control a la posici n abierta 5 Asegurarse de que el piloto est encendido El cierre de detector de agua ahora est configurado para funcionar en caso de fuga del calentador de agua Nota la falta temporal de alimentaci n a la unidad de control no har que el piloto se apague La unidad de control mantendr el piloto encendido por hasta 8 horas El Cierre de detector de agua Floodsafe no funcionar como se espera sin alimentaci n Se encuentra disponible una bater a de refuerzo para permitir el funcionamiento por 36 a 48 horas en caso de un corte de energ a ADVERTENCIA DE ACUERDO CON LA PROPOSICI N 65 DE CALIFORNIA ADVERTENCIA Este producto contiene qu micos que el Estado de California considera que causan c ncer y defectos Almohadilla de detecci n de agua de nacimiento u otros da os durante la gestaci n La ley del Estado de California requiere que se proporcione esta advertencia a los clientes de dicho estado Para m s informaci n www watts com prop65 Garant a limitada Watts Regulator Co en adelante la Compa a garantiza por un per odo de un a o a partir de la fecha de embarque original que sus productos est n libres de defectos en materiales y mano de obra bajo condiciones de uso normal En caso de que se encue
26. the interconnecting cables To remove an interlocking cable use the supplied Pocket Screwdriver to depress the tab on the cable while pulling cable from its socket Figure 5 Important Interconnecting wires must not touch or be in close proximity to any flame or hot surface a If no drain pan exists install the Water Dam around the perimeter of the water heater The Water Dam can be cut so that it fits approximately 1 to 2 inches outside the diameter of the water heater and includes the area where the Tem perature and Pressure safety relief drain tube terminates b Install the plastic connector supplied with the Water Dam into both ends of the Water Dam so that no gap exists between the ends Figure 6 and Figure 6a 5 Install the Power Cutout Module Figure 7 to the water heater as indicated Upon completion of the installation of the Power Cutout Module route the connecting cable to the Control Unit and insert the interlocking connector to the circuit board Figure 7 Standing Pilot Operation 1 Remove the thermocouple from the gas valve Figure 8 2 Install the Power Cutout Module supplied with the Water Detector Shutoff to the gas valve Figure 9 3 Install the thermocouple to the Power Cutout Module Figure 10 4 H Figure 8 Figure 9 o Figure 10 4 Remove the green circuit board terminal strip from the Control Unit by pulling straight out on the terminal strip Figure 11 5 Install wiring The wire is installer su
27. ure d alimentation Les c bles fournis ne doivent pas tre coup s ou prolong s En cons quence une installation distance n est pas recommand e La plaquette du d tecteur d eau fournie avec le dispositif d arr t avec d tecteur d eau doit tre plac e aussi pr s que possible du chauffe eau Il n est pas n cessaire de retirer le couvercle de unit de contr le pour installer les c bles d interconnexion Rev tement de sol Sol en terre battue Un bac de r cup ration en m tal ou en plastique doit tre install sous le chauffe eau Placer la plaquette du d tecteur d eau dans le bac de r cup ration Sol en ciment Installer la barri re hydraulique fournie avec le kit d installation du dispositif d arr t avec d tecteur d eau autour du diam tre ext rieur du chauffe eau Placer la plaquette du d tecteur d eau l int rieur du p rim tre form par la barri re hydraulique Installation dans un grenier Un bac de r cup ration en m tal ou en plastique doit tre install sous le chauffe eau Placer la plaquette du d tecteur d eau dans le bac de r cup ration Robinets de gaz veilleuse permanente Les thermocouples utilis s sur les robinets de gaz de certains fabricants ont un filetage gauche au leu du filetage droite plus commun Watts a les deux mod les S assurer d avoir le mod le correct avant de commencer l installation Mod les WDS SP L Filetage a gauche WDS SP R
28. vice Rd Burlington ONT L7L 5H7 www wattscanada ca IS WDS SP 0841 EDP 1915995 Watts 2008 Serie WDS SP L WDS SP R ADS Cierre de detector de agua FloodSafe Tama os 3 4 y 1 20 y 25 mm Leer todas las instrucciones identificar todos los componentes y leer todas las advertencias antes de comenzar con la instalaci n de este producto Este producto fue dise ado para prevenir da os catastr ficos ocasionados por el agua en caso de fuga en un calentador de agua Nota durante una condici n de funcionamiento de emergencia la v lvula de alivio de temperatura y presi n instalada en su calentador de agua puede descargar una cantidad excesiva de agua El producto est dise ado para proteger su hogar o negocio del peligro potencial de una explosi n Al detectar la descarga de agua el Cierre de detector de agua FloodSafe corta el suministro de agua y la fuente de alimentaci n gas aceite o electricidad al Calentador de agua previniendo una situaci n muy peligrosa El Cierre de detector de agua FloodSafe tambi n cuenta con una alarma sonora y visual y contactos para sistemas de alarma monitoreados Es un dispositivo que puede reiniciarse y puede probarse en cualquier momento para garantizar un funcionamiento adecuado Piezas incluidas Unidad de control M dulo disyuntor de alimentaci n Fuente de alimentaci n WWWATTS Almohadilla de detecci n de agua Destornillador de bolsillo Nota importante se

Download Pdf Manuals

image

Related Search

Related Contents

Brodit ProClip 521630  Z29745 - Lidl Service Website  SM1776 Imp - Instructions Manuals  Omron Healthcare HJ-150 User's Manual  トップパネル取扱説明書 トップパネル組立説明書  Product Safety Campaign 84-C-15B Non-Collision  Panasonic KX-TG2235B KXTG2235 Cordless Speakerphone with Talking Caller ID, Brand (PAKXKXCOSPWI1)  user manual in pdf  SP003-OmniAmp-Supplemental Protocol  Califone KM-TI User's Manual  