Home

Service Guide

image

Contents

1. Landauer s thermoluminescent TLD ring dosimeter measures radiation exposure due to x beta and gamma radiation with a lithium fluoride chip E The TLD chip is safely encapsulated inside the identification cover No separation of the TLD from the cover is possible so the identity of the chip and the wearer is always maintained The cover and TLD are independent of the ring base Identification on the cover is laser engraved preventing the print from smearing peeling or washing off Rings can be worn in dry or wet working conditions and cold sterilized without compromising the integrity of the dosimeter Information engraved on the ring cover is as shown in the Ring Dosimetry section Rings are available in sizes small medium large and extra large Unless otherwise instructed the medium size is sent The color of the ring base changes red blue or black each wear period to help identify wear dates During analysis in our laboratory the TLD chip is heated causing it to become luminescent in proportion to the amount of radiation exposure The luminescence is measured and a report of exposure results is generated The glow curve of the readout that permits a more conclusive evaluation of radiation exposure can be retrieved and analyzed before the exposure report is generated if any anomaly appears The sum of the high energy beta gamma and x radiation is reported as a shallow dose If the ring dosimeter is exposed to radiation other
2. for the gestation period 5 Radiation type and in some cases energy of radiation contributing to whole body dose equivalent Code Radiation Quality Description Type and or Energy B Beta BH Beta high energy e g strontium phosphorus BL Beta low energy e g thallion krypton BN Beta neutron mixture NF Neutron fast NT Neutron thermal P Photon x or gamma ray PB Photon beta mixture PBN Photon beta neutron mixture PH Photon high energy greater than 200 keV PL Photon low energy less than 40 keV PM Photon medium energy 40keV to 200 keV PN Photon neutron mixture 6 The dose equivalent columns report the current and accumulated exposures for deep lens of eye and shallow dose equivalents O DDE Deep dose equivalent applies to external whole body exposure at a tissue depth of 1 cm 1 000 mg cm 23 Landauer Service Guide C LDE Eye dose equivalent applies to the external exposure of the lens of eye at a tissue depth of 0 3 cm 300 mg cm O SDE Shallow dose equivalent applies to the external exposure of the skin or an extremity at a tissue dept of 0 007 cm 7 mg cm averaged over an area of one square centimeter Deep lens of eye and shallow dose equivalents report for the time frame indicated by For Monitoring Period Individual radiation component results and combined totals report in separate lines Quarterly accumulated results total dose received within the calendar
3. 3 month time frame The quarterly columns for bimonthly service display N A not applicable Year to date accumulation totals dose received from the beginning of the current year to the present reported wear date Lifetime accumulation totals all dose received from the inception date of dosimeter service to the present reported wear date and could include earlier dose history if supplied by customer Dose equivalent results are reported in mrem millirem in the US or mSv millisieverts internationally Internal exposure if applicable is summed with Landauer external dose equivalents Total effective dose equivalent is the sum of both deep dose equivalent external exposure and committed effective dose internal exposure Optional Feature Internal Dose Landauer can store the following internal dosimetry information when supplied by you CDE organ CEDE total intake quantity by radionuclide mode of intake and lung clearance class Total CEDE is entered if calculated or is calculated by Landauer Participant records are updated to reflect the internal contribution to the TODE and the TEDE Confirmation reports printed the same day reflect data supplied to Landauer whereas standard dosimetry reports generated by processing external dosimeters reflect the single maximally exposed organ along with CEDE TODE and TEDE For explanation of acronyms see glossary 7 The date Landauer began keeping dosimeter records for a given dosimeter
4. 500 mrem 5 MSV sss 34 Neutrak Dosimeter Specifications 00 0 cee ceecesceseeeseeeseecseceaeceaecsseesseeseesseeseeeseaeeeaeessaecaaecsaesaesnaeeaeees 35 Rinig Dosimeter Specification ue ioco 36 Glossary of Selected Terms from CFR 20 Chapter 10 ooooooccnoconococonononoconoconnnonnnona nono nono nonnc conan nccnnccnnccnns 37 Landauer Service Guide Welcome to Landauer Dosimetry Service Landauer basic radiation dosimetry service includes automatic exchange out of dosimeters each wear period processing and analysis of dosimeters data management archival storage of exposure results standard radiation dosimetry reports with customer service and technical support programs An Overview of How Landauer Provides Your Dosimetry Service l You contact Landauer with your order and your request is entered into our computer system The computer accesses checks and updates your account Our computer system generates instructions to create a dosimeter for your next and successive scheduled wear period shipments Serial numbers are assigned to dosimeters We assemble the dosimeter print the packing list and ship your order to arrive at your location just before the beginning of the wear period We include a control dosimeter with the shipment to monitor exposure in transit and storage You receive your shipment and distribute the dosimeter for use After use at the end of the wear period you replace the used dosim
5. Account Subaccount CAS groups for more consistent pricing and subscription services O Enable tracking or trending data within a Customer o Search across multiple Accounts and or Subaccounts within a Customer a Dose history Client profile O Accounts can support unlimited number of frequencies CJ Moving participants from one Account to another is made easier C Unique participant number assignments within a customer Optional Feature Additional Identification Fields Participants may carry 11 ID types Customer can select the primary ID to show on all reports New customer defined Customer Reference ID is available on subaccount series for structuring your program 15 Landauer Service Guide Exchange Frequencies Exchange intervals from one week up to one year are available dependent on type of dosimeter and dosimetry service O Weekly each Monday O Bi weekly alternate Mondays O Semi monthly 1 and 15 of the month CJ Monthly O Bi monthly alternate months O Quarterly O Semi annual CJ Annual C One time only C 2 year extension for Emergency Response dosimeters Service rates may vary with exchange frequency Invoice and Payment Your initial invoice is sent to you approximately one month after your receive your first shipment Invoices are mailed via US mail and or can be viewed online at our website Products and services are invoiced in advance for the following minimum order periods based on exchange
6. Optional Feature Email Notifications esses nennen eren cnn cnn enn n cnn rana ennes 7 Dosimeter Bn H H 7 Control DoStmetets ee cn nice te ert pete oec ptr eo ves ves india ico di dida Vin De eara latinas 8 Optional Feature Subaccount Series Control Dosimeter eee 8 Optional Feature Control Dosimeter netten repo ten diia teres rua dote 8 Optional Feature Automatic Background Subtraction NCRP No 94 sss 8 Optional Feature Automatic Custom Background Subtraction eese 9 Optional Feature No Background Subtraction esses eerte nnne nenne 9 Feature Report Control Bxposute siere hrnci d enini Eod e ebd reet Debra o se rre Esp dk oii aa 9 I CS Dosimetry SErVICE rr 9 IB COE SEDI qe EE 10 Ring Dosimetry Service P 11 InLight Dosimetry Service T 11 Environmental Dosimetry Service ecciesie eed eee e Ecce a debts Fee EL e eres decada dina 12 Return Dosimeters to Landauer for Processing cccsscceesceceeeeesseeeeeseeceeneeeeeecaeessaaeceeaeeceaeeeeaeceeaeecenees 12 Unreturned Dosimeters a ori efe bri e eti iii 13 Emergency Processing li oie pu uev pim e nones i rie tatu e E 13 Early Notification of Dose Above Specified Exposure Level ooonnccnnccnoncnoccconcconncnncnonnnonanonnononcnoncnnacnnanns 14 Optional Feature Set Expsosure Levels for Early Noti
7. THOMAS ROBERT 355896211 1965 08 15 NA NA IDE 1 CALCULATION WALKER JANE 296687544 1963 02 15 SUMMERS DAVID 358479506 1952 02 18 Proper control not retuned agency of the federal government 1 Within a Customer a unique permanent number assigned by Landauer identifies each individual 20 Landauer Service Guide Optional Feature Sort Order The default sort order for the dosimetry is by participant number Data within a report or packing list can also be sorted alphabetically by participant name If you have a subaccount series the default sort is by subaccount series code and participant number or you can elect to sort by subaccount series code and participant name 2 Participant s personal information consisting of name ID number and birth date Participants may have up to four ID types and a job classification The participant s gender is maintained with participant information only and not shown on dosimetry reports Optional Feature Privacy Options For privacy and or posting needs you can request that we suppress fields on the original report check with your regulatory agency for your specific reporting requirements Privacy Options available are C Low suppress ID number and date of birth CJ Medium suppress last name all but last four numbers of SSN and date of birth O High suppress all except participant number 3 Landauer dosimeter type according to monitoring
8. a cellophane wrapper as unused excluding control dosimeters O Return to Landauer the rings Neutrak InLight Environmental and or other dosimeters along with their control dosimeter s of the same type and wear date If you are returning a duplicate dosimeter s for a wear period to obtain credit for the replacement fee and you do not want the dosimeter s reported as unused return the dosimeter s in a bag separate from the regular wear period dosimeters Please include 1 List of the dosimeters returned for the replacement fee credit 12 Landauer Service Guide 2 Statement with an authorized signature verifying the dosimeters are being returned for replacement fee credit only and you do not wish to have them processed and reported as unused Unreturned Dosimeters Return all used and unused dosimeters at the end of each wear period A dosimeter including a control dosimeter is considered lost if it is not returned to Landauer within 90 days after the end wear date There is a replacement fee for each dosimeter not returned A warning report after 45 days will be issued listing the dosimeters that have not been returned Emergency Processing Emergency processing is available for dosimeters suspected of receiving overexposure Call Customer Service 800 323 8830 Please have the following available O Account number CJ Name and phone number of the person to be contacted with the dose reading s O Number and types o
9. and optical radiations 32 Landauer Service Guide Radiation Type Energy Range Minimum Dose Maximum Dose Equivalent Reported Measurement Photon x or gamma ray 5 keV to 20 MeV 5 mrem 50 uSv 1000 rem 10 Sv Beta Particle 150 keV to 10 MeV expressed 10 mrem 100 uSv 1000 rem 10 Sv as average energy Neutron Fast optional CR 39 40 keV to 40 MeV 20 mrem 200 uSv 25 rem 250 mSv Neutron Thermal Intermediate Fast 0 25 eV to 40 MeV 10 mrem 100 uSv 25 rem 250 mSv optional CR 39 Albedo Neutron optional albedo slide InLight is accredited by NVLAP NVLAP Lab Code 100518 0 for Whole Body ANSI HPS N13 11 2009 in comprehensive subcategory General in all categories including VIA when fast neutron component is added No accreditation is available from NVLAP for thermal neutron dosimeters InLight EX and EX9 Environmental Dosimeter Specifications The InLight Environmental Dosimeter is built on an assembly of a case component with filters along with a Al203 C detector slide component The case and slide are sealed in a robust vinyl pouch Both the case and slide are uniquely bar coded with serial numbers for chain of custody and sensitivity identification AO XA003804777 Radiation Type Energy Range Minimum Ambient Dose Maximum Dose Equivalent Reported Measurement Photon x or gamma 5 keV to 20 MeV 5 mrem 50 uSv 1000 rem 10 Sv ray High Sensitivity 0 1 mrem 1 uS
10. the gestation period The addition of a fetal dosimeter also generates an additional page to the standard radiation dosimetry report that reports only the exposure to the declared pregnant worker and the embryo fetus Multiple Employer Total Exposure Report METER V A monthly report that lists individuals who have had activity in other Landauer accounts during the reporting year Each individual s exposures are summedacross all facilities to help compare the totals with regulatory limits METER helps to satisfy the information required for the NRC s and state agencies requirement that occupational exposures be controlled within limits for all sources of on the job exposure 28 Landauer Service Guide REIRS and REMIT Reporting This service provides year end exposure data compatible with the REMIT program used to electronically transmit information to NRC s REIRS database ALARA Compliance Personalized ALARA Memos ALARA memo service generates a memo for each individual whose dose levels exceeded the quarters ALARA As Low As Reasonably Achievable levels ALARA levels 1 and 2 can be set or NRC guidelines can be used The personalized memo stating the exposure and level exceeded is sent to the radiation safety officer for review and can then be presented to the individual Level 2 memos include a questionnaire to help investigate the exposure ALARA Detailed Recaps An annual and quarterly ALARA report that lists all individuals wi
11. to Landauer customers who have previously set up a web account with Landauer An account s dosimetry coordinator RSO can initiate the creation of a web account on the website at the myLDR Customer Log In page under New Users by selecting Create Log in Once the Log in Creation form is successfully submitted the user ID and password are mailed to the account s reporting address via first class mail to ensure security Please allow 3 to 7 days for mailing Web Account Setup When you set up your web account on the website the account data must be entered exactly as it appears on your radiation dosimetry report including spacing spelling and punctuation to be successful 17 Landauer Service Guide Browser Requirements Our website is best viewed with Microsoft Internet Explorer PC version 5 5X SP2 or above Cookies The myLDR website requires the use of cookies to authenticate your access to the Landauer website A cookie is a small piece of information sent from a web server to a browser to be read back later by the application No personal information is collected If you are unable to view screens please ensure the use of cookies is not restricted through your browser settings Optional Feature Email Notifications You can have an email sent to you notifying you when the following information is available to view online at Landauer s website CJ Inbound and outbound shipment tracking information CJ Over exposur
12. to you and or can be viewed online at our website Reports cover each wear period and include cumulative totals personal data and identification explanatory information and other pertinent data used in the management of a dosimetry program These reports comply with NRC Nuclear Regulatory Commission OSHA Occupational Safety and Health Administration or DOE Department of Energy regulations Reports are generated in a standard letter size format and an explanation page accompanies your reports Optional Feature Duplicate Copies Duplicate copies of dosimetry reports can be mailed on a regular basis to the same address or to another address you designate Optional Feature Access Dosimetry Reports Online You can access dosimetry reports online at Landauer s website myLDR View and print reports with or without suppressed data fields See Landauer s Website www landauer com for log in information Optional Feature Paperless All customers will be able to retrieve multiple PAPERLESS reports Reports will be available on myLDR as soon as they are created SAMPLE FACILITY RADIATION SAFETY OFFICER BULDING 6 LANDAUER Landauer Inc 2 Science Road 1000 HIGH TECH AVENUE Glenwood Minois 60425 1586 GLENWOOD IL 60425 Account 103702 Subaccount 123456 Serios RAD Radiation Dosimetry Report 1 2 3 4 15 MARK HAROLD 388459722 1953 02 15 1966 12 22 TERS ELIZABETH 355792544 1962 09 08 O
13. 1 and EDE2 calculation results follows all of the original whole body dosimeter doses EDE Effective Dose Equivalent 9 This is an example of what appears on your report when a dosimeter was not returned for processing for the wear period and you have elected to have Absentee Reporting see following apply for your account Optional Feature Absentee Reporting A dosimeter if not returned for the wear period is noted as absent on the dosimetry report This feature is triggered when 8046 of the account s dosimeters for the specific wear period are reported A different percentage level can be requested with the lowest setting being 30 and the maximum setting at 99 Optional Feature ESTimate Report Landauer can arrange to automatically calculate an estimated dose for a missing dosimeter for a wear period This estimate appears in your exposure report and is automatically updated when the actual dosimeter is returned or a formal declaration of a calculated dose is received A monthly summary report of outstanding estimates with an easy method of converting estimates into calculated doses is included in paper format or can be accessed online at Landauer s website 25 Landauer Service Guide 10 This is an example of a dose for a dosimeter from a calculation given by a customer rather than from a Landauer dosimeter analysis IVA Account 103702 Subaccount 123456 Series RAD Consolidated Radiation Do
14. Name Line 2 po EE InLight Dosimeter Specifications Fr 3 3 ue An Light Systems a InLight dosimeters measure x gamma and beta radiation exposure with aluminum oxide detectors Al203 C read out by optically stimulated luminescence OSL technology The read out process uses a light emitting diode LED array to stimulate the detectors and the light emitted by the OSL material is detected and measured by the photomultiplier tube PMT using a high sensitivity photon counting system The amount of light released during optical stimulation is directly proportional to the radiation dose and the intensity of stimulation light A dose calculation algorithm is then applied to the measurement to determine exposure results The OSL read out process allows for dose verification through complete reanalysis The InLight dosimeter is built on an assembly of a case component with filters along with a detector slide component Both the case and slide are uniquely bar coded with serial numbers for chain of custody and sensitivity identification The InLight carrier is designed to accommodate a case and slide the optional Neutrak CR 39 component for neutron detection see p 31 and the optional imaging component InLight dosimeters are not affected by heat humidity or chemical solvents The Al203 C detector material does not respond to neutron radiation and the packaging material is sufficient to shield the dosimeter from alpha
15. Service Guide LANDAUER Landauer Service Guide PROPRIETARY RIGHTS NOTICE This user manual contains proprietary and confidential information of Landauer Inc This manual is furnished under license only for the use and information of the licensee and the content is subject to change without notice Use of the contents of the manual for any purpose other than that for which it was provided is prohibited and this manual may not be reprinted or redistributed to any third party without the written consent of Landauer Inc Landauer Inc does not warrant or guarantee the contents of this user manual Landauer InLight and Luxel are registered trademarks of Landauer Inc in the United States and other countries All other company product and service names and brands are the trademarks or registered trademarks of their respective owners LANDAUER 2012 by Landauer Inc All rights reserved Landauer Service Guide Table of Contents Welcome to Landauer Dosimetry Service eessessseeseeeeeeeee ene nennen 6 An Overview of How Landauer Provides Your Dosimetry Service esee 6 Available Technical Support eei tarta tratta retta ch vocesueysadeeadbsineostsbatvaastuasesssteatseetaatinssteseneat 6 Gs AAA T 7 AMIA NR 7 Optional Feature Shipments to Multiple Sites eese nennen nennen 7 Optional Feature Shipment Tracking Online eese renes nnns 7
16. bodies or tissues DAC Derived air concentration is the concentration of a given radionuclide in air which if breathed for a working year of 2 000 hours under conditions of light work results in an intake of one ALI DDE Deep dose equivalent applies to external whole body exposure is the dose equivalent at a tissue depth of 1 centimeter DE Dose equivalent is the product of the absorbed dose in tissue quality factor and all other necessary modifying factors at the location of interest The units of dose equivalent are the rem and sievert Sv External dose is that portion of the dose equivalent received from radiation sources outside the body Internal dose is the portion of the dose equivalent received from radioactive material taken into the body LDE Eye dose equivalent refers to the external exposure of the lens of the eye and is taken as the dose equivalent at a tissue depth of 0 3 centimeter 37 Landauer Service Guide SDE Shallow dose equivalent applies to the external exposure of the skin or an extremity and is the dose equivalent at a tissue depth of 0 007 centimeter averaged over an area of 1 square centimeter TEDE Total Effective Dose Equivalent is the sum of the deep dose equivalent for external exposures and the committed effective dose equivalent for internal exposures TODE Total Organ Dose Equivalent is the sum of the deep dose equivalent and the committed effective dose equivalent to the o
17. dosimeters in the shipment the control dosimeter exposure is not subtracted In such an event it is noted at the bottom of the dosimetry report that the control dosimeter was not used in the assessment of the reported exposure results Optional Feature Automatic Background Subtraction NCRP No 94 Landauer can arrange to automatically subtract a calculated average background exposure from the dosimeters in your shipment when a valid control dosimeter is not available The Landauer Service Guide service calculates a fraction of a millirem per day that totals approximately six mrem sixty mS v per month starting from the manufacturing date of the dosimeter and ending with the read out date The formula for this service is based on the data presented in the NCRP Report No 94 Exposure of the Population in the United State and Canada from Natural Background Radiation published in 1988 by the National Council on Radiation Protection and Measurements Optional Feature Automatic Custom Background Subtraction Landauer can arrange to automatically subtract a customer defined background exposure from the dosimeters in your shipment when a valid control dosimeter is not available Optional Feature No Background Subtraction Landauer can arrange to not subtract the control exposure from the dosimeters in your shipment Feature Report Control Exposure Landauer can arrange to report the control exposure used in the background subtraction from the
18. dosimeters in your shipment Landauer s standard background control subtraction hierarchy is as follows Modifications can be made upon request Use valid control badge from subaccount series or master control 2 If no valid control is available the automatic background subtraction constant is used Client can set up a customer defined background subtraction constant to be used in place of the Landauer default 3 Client can elect to not have the control subtracted Luxel Dosimetry Service Luxel may be packaged for personnel monitoring area monitoring emergency response or other specialized services Standard packaging ships each dosimeter individually wrapped in cellophane along with a card containing account and worker information Holders are packaged separately Remove the dosimeter from the cellophane snap the dosimeter into holder for use and discard the cellophane Landauer Service Guide At the end of the wear period snap the used dosimeter out of the holder and replace it with the dosimeter for the new wear period 09 01 06 103702 RAD 12345 Whole ssec cre Return the used dosimeter along with the control dosimeter s of the same wear date to Landauer to process for exposure Do not return used dosimeters in cellophane packaging Landauer receives and reports all Luxel dosimeters returned in their original cellophane wrapper as unused excluding control dosimeters Store dosimeters away from
19. dosimeters of the same type and wear date when not in use do not store dosimeters near a radioactive source or in a x ray room Control dosimeters have the participant number with 5 zeros for the account and series subaccount with number OORAD imbedded in the participant number Landauer automatically supplies a control dosimeter for each account and can supply additional control dosimeters for each account and can supply additional control dosimeters to help you structure your program for control handling For example if you return dosimeters in many shipments instead of one we can arrange to routinely invoice additional control dosimeters so that you can include a control dosimeter with each shipment returned separately to Landauer for processing Optional Feature Subaccount Series Control Dosimeter If you have elected to set up a subaccount series department grouping for your account and you store each department s dosimeters at a different location at your facility we can supply a control dosimeter to accompany each department grouping with or without a master control dosimeter for each account Optional Feature Control Dosimeter Landauer can replace multiple subaccount series control dosimeters with a control dosimeter when we ship all of your dosimeters to one place and they are stored in one location Exception If a control dosimeter exposure is higher than expected or higher than the majority of the exposures received by the
20. e information O Dosimetry reports O Invoices myLDR offers read only and update capabilities selective by user subaccount etc Minimum Dose Equivalent Reported Dose equivalents for the current monitoring period below the minimum reportable dose are recorded as M The minimum reportable dose varies according to the dosimeter type and radiation quality Optional Feature Selected Limit SL You can elect to change the minimum reportable dose for the Luxel or InLight dosimeter for photon x or gamma ray to 10 mrem 100 uSv All exposures less than 10 mrem 100 uSv will appear as SL Photon x and gamma ray and beta exposures at or more than 10 mrem 100 uSv would begin reporting at 10 mrem 100 uSv and report in increments of 10 mrem 100 uSv 18 Minimal Dose Equivalent Reported Dosimeter Type M DDE SDE M SDE Only SL DDE SDE mrem uSv mrem uSv mrem uSv Luxel 1 10 10 100 InLight 5 50 10 100 Whole Body Beta 30 300 Fetal 1 10 z Ring 30 300 E Environmental Neutrak Neutron Fast 20 200 Neutrak Neutron Thermal Intermediate Fast 10 100 19 Landauer Service Guide Landauer Service Guide Dosimetry Report At the end of each wear period dosimeters returned to our laboratory for processing are analyzed and a dosimetry report for each account is generated Reports are printed and mailed
21. entification in a choice of six different colors see Optional Feature Shipments to Multiple Sites p 5 The graphic formats change in color with each exchange frequency and each season has its own unique icon The account and participant numbers wear date placement 29 Landauer Service Guide location serial number and the dosimeter and component bar codes all ensuring chain of custody appear on the back of the dosimeter see p 8 Optional Feature Background and Graphic Format Options Choose between any combination of four background options and three graphic formats Background options are no background default Dogs Sky or Trees Graphic formats are Side Bar default Corner or Cross The graphic format color sequence can be color coded in a choice of six different colors Background and Graphic Format Option Examples Side Bar Default Side Bar Trees luxel i Cross Sky A Pa Corner Dogs 7 Kel LANDAUER Optional Feature Specialized Holders Specialized holders available O for use in magnetic environments O Luxel wrist dosimeter with Velcro strap for extremity measurements O attached to Velcro squares for vertical substrate area applications Luxel amp Dosimeter Specifications The Luxel dosimeter measures radiation exposure due to x gamma and beta radiation with optically stimulated luminescence OSL technology The OSL radiation detector inside the dosimeter is a thin str
22. eter with the dosimeter for the new wear period and return the used dosimeter along with the control dosimeter of the same wear date to Landauer for processing Our Receiving Department at Landauer logs in all incoming dosimeters into our computer system and assigns an analytical work order number for tracking We analyze the dosimeter review the results then report merge and verify for completeness the results from all separate dosimeter types We permanently archive all exposure results print and then mail your dosimetry report to you or you can go paperless and retrieve reports from our online service myLDR Online report retrieval is available for all reporting services Available Technical Support Corporate Office Landauer Inc 2 Science Road Glenwood IL 60425 Luxel InLight Phone 708 755 7000 Toll Free Phone 800 561 2708 Toll Free Phone 800 323 8830 Customer Service custserv landauer com Technical csrecords landauer com Web Site www landauer com Landauer Service Guide Optional Features Throughout this Service Guide optional features appear Optional features are services or products not automatically supplied with our basic dosimetry service Each optional feature is available by contacting Customer Service and may involve an additional fee or charge designated by Shipment Contents Your shipment contains a packing list dosimeters holders if applicable a control dosimeter s fo
23. f dosimeters being returned O Name of commercial courier for return shipment overnight shipment is required O Source of exposure O Any other information you feel pertinent Enclose a note with the return shipment listing the name and phone number of the person to contact Mark the outside of the package EMERGENCY PROCESSING For shipments received by 10 00 AM Central Daylight Saving Time Landauer will phone the dose results to the point of contact by 4 30 PM Central Daylight Saving Time For neutron dosimeters Landauer will phone the dose results to the point of contact within two business days 13 Landauer Service Guide Early Notification of Dose Above Specified Exposure Level Landauer provides free notification by phone fax email or through new online dashboard in myLDR when an individual s dose exceeds 20 of regulatory limits e g deep lens of eye shallow etc for any given wear period or 50 of the regulatory limit year to date Optional Feature Set Expsosure Levels for Early Notification You can elect to set an individual a subaccount series or an entire account at specific notification levels Account Maintenance Once your service is established you can make changes by contacting Customer Service by mail phone fax email or make changes directly online at Landauer s web site myLDR See Landauer s Web Site www landauer com for log in information Your packing list that accompanied your shipment can also be
24. fication 14 Account Maintenance moriria 14 Customer Hierarchy npe evo nt eec ee ied dg tree Dei dne ollas 15 Landauer Service Guide Optional Feature Additional Identification Fields eese 15 Exchange Frequencies eG ERREUR c OR Eee detta 16 Invoice and Payment o he eee e edt Dee De ott idee ee tice n OR Gas Dee Co eoe tede E De Re ee e eher 16 Landauer s Web Site www landaler COlM oooccnnccnocnnonnnocnnonnconnconncnn nono noconecnnnnnnn cnn conan ener enr en eren sensere 17 Public Section au io e op tue d e e o e e PC e Pte bent astu Re ladies 17 Landauer Customer Section my LDR essere eene nennen nennen nennen enne 17 Optional Feature Email Notifications sese eene eene nennen enne tnter enn enne 18 Optional Feature Selected Limit SE narisane iie i a aE e e e e ES 18 Optional Feature Duplicate Copies iie ee te He ER t e Re edd lee 20 Optional Feature Access Dosimetry Reports Online eese enne 20 Optional Feature Paperless 5 o deiecti Pre HERR eere Tee E etae eR e euro dn 20 Optional Feature Sort Order iE Leere Hec te eis a ire de tcd 21 Optional Feature Privacy Options ici oen poene reto pente eerte eiecit oder teria 21 Optional Feature Fetal Dosimeter nipote ere PEE e EIER RU oec 23 Optional Feature Internal DoS 5 eto tere te ege e o eee bo liniers 24 Optional Feature Special Do
25. frequency O Weekly service 13 weeks O Biweekly or semi monthly service 6 months CJ Monthly bi monthly quarterly or semi annual service one year Product and services are listed by SKU stock keeping unit number The initial invoice includes O One time setup charges for the initial participants C Service fees are applicable for shipping shipping and handling additional dosimeter fee single site and multiple site shipments Actual charges for each shipment such as setup charges for new participants duplicate reports optional reports emergency processing etc are entered into your billing file as each shipment is made At the end of the routine billing cycle the actual charges are printed on a new invoice and 16 Landauer Service Guide credit is given for the amount previously invoiced in advance Services consumed over and above the invoice will be charged at the customer s current rate All invoices are due and payable net thirty 30 days after invoice date Statements are issued monthly on all open accounts thirty 30 or more days past due and finance charges of 1 1 2 per month an annual percentage rate of 18 may be assessed When making payments enclose a copy of the invoice or refer to your account number to ensure proper crediting of your remittance Payments by credit card can be made online on Landauer s secured website as indicated on your invoice The duration of the service contracted shall be the peri
26. he same wear date to Landauer to process for exposure Environmental Dosimetry Service The InLight Environmental dosimeter is for both indoor and outdoor use and is designed to withstand extremes of temperature humidity precipitation and other environmental conditions The dosimeter is sealed in a heavy duty vinyl tamper resistant pouch that has multiple slots to permit several methods of attachment for easy deployment 291199 INTERNATIONAL FACILITY SITE JAN 01 is 01 2008 gt Irc vi id LA InLight s standard environmental dosimetry service 5 mrem 50 uSv minimal reporting EX supplies one control to monitor radiation received in transit and storage InLight s high sensitivity environmental dosimetry service reporting down to 0 1 mrem EX9 requires a minimum of two controls The first control is for field deployment retrieval used to measure exposure during shipment and placement collection The second control is for transit used to measure exposure during shipment only Return the used dosimeter along with the control dosimeter s of the same wear date to Landauer to process for exposure Return Dosimeters to Landauer for Processing At the end of the wear period to process for exposure O Snap Luxel dosimeters out of their holders and return to Landauer the dosimeters along with the control dosimeter s of the same wear date retain the holders Landauer receives and reports all Luxel dosimeters returned in
27. ip of specially formulated aluminum oxide Al203 C crystalline material During analysis in our laboratory the Al2O3 C strip is stimulated with selected frequencies of laser light causing it to luminesce in proportion to the amount of radiation exposure and the intensity of stimulation light The luminescence measured during analysis is applied to a dose algorithm that relies on the response ratios between different filter positions within the dosimeter to discriminate between beta and photon x and gamma radiation fields to determine exposure results Dose equivalents arising from exposures to photons x or gamma rays will have a deep lens of eye and shallow value reported Depending on the energy of the x or gamma rays these values mayor may not be equal Beta exposures are reported only as a shallow dose equivalent Luxel is an integrated self contained packet that comes preloaded incorporating the Ab03 C strip sandwiched within a multi element filter pack that is heat sealed within a laminated light 30 Landauer Service Guide tight paper wrapper All of these components and the optional Neutrak CR 39 are sealed inside a tamper proof plastic blister pack to eliminate possible mishandling light leakage or lost detection elements Luxel may be used for up to one year It is unaffected by heat moisture and pressure when he clear blister pack is uncompromised Radiation Type Energy Range Minimum Dose Maximum Dose Equi
28. ncurs only upon generation of the report Exposure Management Services Statistical Summary An annual report summarizing an organization s range of exposure on a single page The summary breaks out deep dose exposure levels from no measurable exposure to increments above regulatory limits and shows how many workers are in each range ESTimate amp A monthly service that computes an estimated dose for a missing body eye or ring dosimeter for a wear period The estimated dose automatically appears in exposure reports identified as an estimate and is used to compute the assigned dose A monthly report lists all outstanding estimates together with dosimeter data used to compute the estimated doses Other dosimeters worn by the individual for the wear period are included in the report for context to provide all the essential information needed to easily decide what calculated dose is appropriate ESTimate is an excellent way to track exposure trends and ALARA levels when a dosimeter is late or missing available in paper format or online at Landauer s website Fetal Monitor Service A monthly service that tracks exposure of a declared pregnant worker and embryo fetus by reporting exposure of the mother wearing a whole body dosimeter and an additional fetal dosimeter The report lists estimated dose from conception to declaration rolling exposure history by month for both pregnant worker and the embryo fetus and accumulated fetus totals for
29. ne radiator for fast neutrons while the right area uses a boron loaded Teflon radiator for fast intermediate and thermal neutrons that also records alpha particles resulting from neutron interactions in the dosimeter During analysis in our laboratory the CR 39 is etched in a chemical bath to enlarge exposure tracks The fast neutron dose is measured by counting the tracks generated as a result of the proton recoil with the polyethylene radiator while the thermal intermediate dose is measured by counting the alpha tracks generated with the boron radiator One value is reported for deep lens of eye and shallow dose equivalent Neutron Type Energy Range Minimum Dose Equivalent Reported Maximum Dose Measurement Fast 40 keV to 40 MeV 20 mrem 200 uSv 25 rem 250 mSv Thermal Intermediate Fast 0 25 eV to 40 MeV 10 mrem 100 uSv 25 rem 250 mSv Accreditations Approvals Licenses C NVLAP NVLAP Lab Code 100518 0 for Whole Body ANSI HPS N13 11 2009 in subcategory General in all categories including VIA when the fast neutron component is added and for extremity ANSI HPS N13 32 2008 No accreditation is available from NVLAP for thermal neutron dosimeters O CNSC Canadian Nuclear Safety Commission Dosimetry Service License O HSE Health and Safety Executive United Kingdom approved for Whole Body OSL and Whole Body Neutrons 35 Landauer Service Guide Ring Dosimeter Specifications
30. needs Dosimeter Type of Radiation Monitored Imaging Options Photons Neutrons Name Prefix X Gamma BH Beta Beta Fast Fast Thermal Albedo High Low Energy Energy InLight with or without Neutrak Fast L02P or Thermal Intermediate Fast L02J LO2T InLight with Albedo Neutron detector L04K with or without Neutrak Fast or Thermal Intermediate Fast LO4L L04M 21 Landauer Service Guide Dosimeter Type of Radiation Imaging Monitored Options Name Prefix Photons Neutrons InLight Environmental V03P V06P Luxel with or without Neutrak Fast or P Thermal Intermediate Fast Ring Single TLD U 4 The use or location on the body for which the dose is given Use Description Use Description AREA Area Monitor LWRIST Left Wrist Other CHEST Chest OEXTRM Extremity CNTRL Control OWHBDY Other Whole Body COLLAR Collar RANKLE Right Ankle EYE Eye RFINGR Right Hand Ring FETAL Fetal RUARM Right Upper Arm LANKLE Left Ankle RULEG Right Upper Leg LFINGR Left Hand Ring RWRIST Right Wrist LUARM Left Upper Arm SPECL Special Purpose LULEG Left Upper Leg UPBACK Upper Back LWBACK Lower Back WAIST Waist Note in this column indicates a message explaining any abnormalities imaging and reanalysis results or elected optional features and is printed on a separate line below the do
31. od indicated on the order and shall without further notice be renewed for a successive like period of service unless written notification is given by either the buyer or seller at least 30 days prior to the end of any service period Landauer s Web Site www landauer com Public Section Landauer s web site contains resources conveniently available to you anywhere you have access to the Internet The public section of the web site features information about Landauer our products and services useful links to other websites and FAQ frequently asked questions Through the FAQ page you can search the answer database submit a request to our support staff who will reply to you by email or log in to check the status of a request you can log in user ID and password for the public section directly on the website Landauer Customer Section my LDR The customer section is a self service website where you can managed and report your account data Log in to review and edit account information and services Add edit or deactivate subaccounts series participants and dosimeters Track shipments and unreturned dosimeters Review invoices and payment history Review and print dosimetry and optional reports or use a wide range or search criteria to create your own report myLDR has secure data encryption offering full and limited log in access levels that control what account data is displayed and what changes can be made myLDR is accessible only
32. r each dosimeter type and a return envelope or label to be used to return your dosimeter s to our laboratory for processing All routine shipments from Landauer Inc to the client are F O B Free on Board destination via first class mail A request for overnight delivery will incur a minimum fee per package for handling and shipping Return shipment fees are paid by customer Optional Feature Shipments to Multiple Sites All routine shipments are sent to a central location or can be sent to multiple sites subaccounts series at the same address or to different addresses A subaccount series within an account is segregated on dosimetry reports and the subaccount series name or code appears on the dosimeter Optional Feature Shipment Tracking Online Check the order status of your shipment online or log in to Landauer s web site and track when where and how your shipment was sent Details such as wear period frequency series quantity of dosimeters shipped shipping charges carrier and tracking number if applicable can be viewed anytime you have access to the Internet See Landauer s Web Site www landauer com for log in information Optional Feature Email Notifications Landauer can automatically send you an email notification when new shipping information and all reports are available to view online through myLDR Dosimeter Use Use the dosimeter s beginning on the wear date or as close to that date as possible An icon on
33. radiation when not in use do not store near a radioactive source or in a x ray room Information printed on each Luxel dosimeter p T NN PARTICIPANT NAME ACCOUNT NAME PARTICIPANT NAME WN Wen NAME SITE NAME q PARTICIPANT ACCOUNT NAME a LANDAUER luxel LANDAUER 09 01 06 103702 RAD 12345 Whole esa cre Luxel Back 10 Landauer Service Guide Ring Dosimetry Service Landauer ships rings in a plastic bag along with the control dosimeter Remove ring s from bag for use Store dosimeters away from radiation when not in use do not store near a radioactive source or in a x ray room Return the used ring along with the ring control dosimeter s of the same wear date to process for exposure 4292411R SUMMER DAVID MAN 1 2006 LO 113624RAD 0000 Ring sizes are available in small medium large and extra large with the default being medium if no size is specified InLight amp Dosimetry Service InLight can be packaged for personnel monitoring area monitoring emergency response or other specialized services Standard packaging ships dosimeters with an attached alligator clip or a slotted clip Information found on each InLight dosimeter T HM E July 2007 3 PARTICIPANT k SITE NAME n oror 1007 Sm PE PARTICIPANT NAME PO a Em 11 Landauer Service Guide Return the used dosimeter along with the control dosimeter s of t
34. rgan receiving the highest dose as described in 10 CFR 20 2106 a 6 38
35. s for a badged participant on the current account 8 This example shows how a special dose calculation EDE 1 is applied to a participant who wears a collar and a waist dosimeter with a lead apron Optional Feature Special Dose Calculations Special calculations permit departure from Landauer s standard dose assessment protocol in order to provide a more accurate estimation of radiation dose under special circumstances as determined by your Radiation Safety Officer Special calculations can be applied to an individual a subaccount series or to an entire account Special dose calculations available for radiation workers who wear lead aprons are EDE 1 Two dosimeters One dosimeters is worn at the waist level under a lead apron and one dosimeter is worn at the collar level outside the lead apron 1 5 Waist DDE 0 04 Collar DDE Assigned Deep Dose Equivalent 24 Landauer Service Guide Note Both waist and collar dosimeters must be returned together When only one dosimeter is returned without the second the whole body dose equivalent is calculated per Landauer s standard dose assessment protocol Then when the second dosimeter is returned the dose is recalculated creating an assigned dose equivalent as if both the waist and collar dosimeters were returned at the same time EDE 2 One dosimeter One dosimeter is worn outside the lead apron 0 30 Collar DDE Assigned Deep Dose Equivalent The Assigned line with the EDE
36. se Calculations eese enne nne 24 Optional Feature Absentee Reporting eee eeccesceeeneeeeeeseeeseecssecseceseeeseeseeeseeeseaeeeneesaaecsaecaecnaeseaeens 25 Optional Feature ES Timate 9 Report eei eerie bee dee cire tbe tette pa 25 Optional Reports ette Het eH Ee Ut NR REPE EE UU EE Pod eese ble e tum bus 27 Compliance Individual Reporting Requirements eese eren eren nennen 27 Exposure Management Services cts ane in eei ee E ea ade die P a tte 28 ALARA Compliance toe HA RICH dec dit cere ect 29 Report Management Services s oce petere de Ee ee E heen Ee o ees teneo ie dete ipd 29 Special and Other Services e e iet e erect hui a epa e ees et ep e ee pere euge 29 I uixel amp r Administrative Features ee dieit ete qe HP EHE eb ovo on Pr C ded 29 Optional Feature Background and Graphic Format Options sese 30 Optional Feature Specialized Holders eee eee en rennen 30 Luxel amp F Dosimeter 5pecifications dente ettet eere AA teret 30 InLight amp Administrative Features esses nennen tenente nter enne enne 31 Landauer Service Guide InEight Dosimeter Specifications vecinita ert ae cce Deere erc eie lee ete deceased dn 32 InLight EX and EX9 Environmental Dosimeter Specifications oconoccnoncnoncconnnonnnnnnonanonanono conocio conc cnnannna ns 33 EuxelO EMI MAI AS c 34 Optional Feature Reanalysis or Imaging at Less than
37. simeter exposure information Landauer reports the dose or record as whole body for a person not a dosimeter Landauer s standard dose assessment protocol is to report deep and shallow whole body dose from the highest reading whole body dosimeter and the lens of eye dose from the dosimeter closest to the eye Assign appears when more than one whole body dosimeter is worn is equal to the highest whole body dosimeter exposure and is reported as dose of record 22 Landauer Service Guide Landauer s whole body dosimeters include the chest collar waist upper or lower back right or left upper arm or right or left upper leg A Landauer designated other whole body dosimeter is intended for information purposes only and is not included in the calculation of the whole body dose equivalent for the current monitoring period or cumulative history Optional Feature Fetal Dosimeter You can track the exposure of a declared pregnant worker and embryo fetus by adding a fetal dosimeter The addition of a fetal dosimeter generates an additional page to the standard radiation dosimetry report that reports only the exposure to the declared pregnant worker and the embryo fetus In addition a monthly summary report is available that reports the estimated dose from conception to declaration if provided by the customer the rolling exposure history by month for both the pregnant worker and the embryo fetus and the accumulated fetal totals
38. simetry Report 3 NoN Supplementary U K Occupational Dosimetry Report Information Radiation type and in some cases energy of radiation contributing to whole body dose equivalent Code Radiation Quality Description Type and or Energy BK Krypton beta BS Strontium beta BT Thallium beta BU Uranium beta NF Neutron fast NT Neutron thermal P Photon x or gamma ray PH Photon high energy greater than 100 keV PL Photon low energy less than 100 keV BN Beta and neutron exposure PB X ray or gamma and beta exposure PN X ray or gamma and neutron exposure PBN X ray or gamma beta and neutron exposure 26 Landauer Service Guide Cumulative Totals Quarterly accumulated results total dose received within the calendar 3 month time frame Note Quarterly accumulated columns for bimonthly service display Not applicable Year to date accumulation totals dose received from the beginning of the current year to present wear date Permanent accumulation totals all dose received from inception date of dosimeter service to present reported wear date Adjustments Adjustments made to cumulative totals with this or previous report at customer request A Additions B Subtractions C Additions and subtractions D Dosage data supplied by customer for period prior E As D additional changes have also been made F Previous lifetime expos
39. th their exposure histories Quarterly reports show which individuals exceeded ALARA Levels 1 and 2 for the quarter and year to date while annual reports quickly show trends by individuals and departments for the year Reports track both individual and collective dose ALARA levels can be set or NRC guidelines can be used Report Management Services Reports on CD ROM This service is an annual accumulation of reports on CD ROM created after the close of a calendar year Digital storage gives you the opportunity to save file space and a search function allows you to browse by account number series participant name or number and wear date to find the report you want to view and print Reports that are currently available on CD ROM are Standard Dosimetry Reports Equivalent Form 5 and Termination Reports Special and Other Services Landauer can support special dosimetry studies where conventional personnel dosimetry is inappropriate Through Special Services much tighter tolerances special calibrations and other non routine functions can be provided Please contact InLight Customer Service for more information Luxel amp 4 Administrative Features The dosimeter s basic design incorporates on the face of the dosimeter your account name the participant name and a dosimeter placement icon indicating correct placement of the dosimeter The subaccount series name is printed over a gray line graphic default or can be color coded for easy id
40. than x ray or gamma over 20 keV or high energy beta the value recorded may require further interpretation on your part Landauer will furnish on request adjustment factors for any specified energy level Radiation Type Energy Range Minimal Dose Equivalent Maximum Dose Reported Measurement Photon x or gamma Greater than 15 keV 30 mrem 300 uSv 1000 rem 10 Sv ray Beta particle Greater than 200 keV expressed as 40 mrem 400 uSv 1000 rem 10 Sv average energy Rings are accredited in extremity dosimetry categories I through VII by the National Institute of Standards and Technology through NVLAP NVLAP Lab Code 100518 0 36 Landauer Service Guide Glossary of Selected Terms from CFR 20 Chapter 10 Except as Noted ALARA As Low As Reasonably Achievable ALI Annual Limit on intake is a derived limit for the amount of radioactive material taken into the body of a worker by inhalation or ingestion in a year that results in a CEDE of 5 rems or a CDE of 50 rems whichever is more restrictive CDE Committed dose equivalent is the dose equivalent to an organ or tissue that will be received from an intake of radioactive material by an individual during the 50 year period following the intake CEDE Committed effective dose equivalent is the sum of the products of the weighting factors applicable to each of the body organs or tissues that are irradiated and the committed dose equivalent to theses
41. the face of the Luxel and InLight dosimeters identifies the correct placement of the dosimeter Icons include whole body and extremity use area monitoring and a special icon designed for fetal monitoring Sample Icons t 0 Body X Area Wear personnel dosimeters with the icon facing away from the body Wear the ring dosimeter on a finger on the hand indicated on the ring cover Landauer Service Guide Personnel dosimeters should be worn during working hours to record occupational exposure NOTE Do not wear dosimeters during non working hours while undergoing diagnostic or medical procedures where exposures would not be part of your occupational exposure history At the end of the wear period return to Landauer all used and unused dosimeters for processing and determination of dose Include in the return shipment any control dosimeter s that accompanies the dosimeters in transit and storage Control Dosimeters A separate dosimeter known as a control dosimeter is included with each shipment to monitor radiation received in transit or storage The control dosimeter exposure can be subtracted from each individual dosimeter exposure in the shipment to separate the occupational dose from the background exposure The control dosimeter s assigned to a shipment should accompany that shipment in transit both from and to Landauer Do not use the control dosimeter for any other purpose Store control dosimeters away from radiation with
42. ure supplied by customer G As F additional changes have also been made Optional Reports In addition to our standard radiation dosimetry report the following optional reports and services designed to help simplify the management of your dosimetry program are available Compliance Individual Reporting Requirements Equivalent Form 4 An annual report detailing cumulative occupational exposure history for an individual The report shows dose since inception of continuous Landauer service and if provided lists prior employer dose records Equivalent to NRC Form 4 this report is used as a tool for transmitting exposure data from one licensee employer to another to gather lifetime histories for all workers requiring monitoring Equivalent Form 5 A report detailing dose history for an individual for the year at a given location The report contains all the information required by NRC Form 5 which satisfies the requirement for an annual report to workers the NRC and other regulatory bodies check with your regulatory agency for your specific requirements Reports are generated annually after the close of a calendar year or quarterly with current data up to the last wear period reported 27 Landauer Service Guide Termination Report Service Service provides an Equivalent Form 5 for presentation to the worker when an individual is deleted from Landauer service Overnight report generation is available upon request Change i
43. used to make changes Mail packing lists with changes separately from your return dosimeter shipment to prevent delays in handling your request All written requests for changes should include your account number subaccount series if applicable participant number and an authorized signature Allow us at least 25 days before the next wear date to make changes Landauer notes the deadline on your packing list when your changes must reach Landauer in Glenwood IL to be effective for the next wear date shipment Landauer manages your account within a Customer Hierarchy that allows us to manage multiple accounts under one Customer Each Customer may have one or multiple Accounts Each Account may have one or multiple Subaccounts Series Each Account or Subaccount Series may have one or more exchange frequencies Each participant has a unique participant number within a Customer 14 Customer Hierarchy Account Structure Today Landauer Service Guide Customer Participants and Dose History E A a Account Account C Dosimeter Ship Reporting Locations A M a Lv vy v New Client Structure The new client structure or hierarchy offers many additional advantages CJ All participant and dose history is stored at the customer level with dosimeters at the location of use being either the account or subaccount series level o Consolidation method to identify a Customer
44. v Beta Particle 150 keV to 10 MeV expressed as 10 mrem 100 uSv 1000 rem 10 Sv average energy High Sensitivity 20 mrem 200 uSv The Inlight Environmental Dosimeter fully meets ANSI N545 1977 NRC Regulatory Guide 4 13 and HPS Draft Standard N13 29 for environmental dosimetry 33 Landauer Service Guide Luxel InLight Imaging The AI203 C aluminum oxide detector can be restimulated numerous times to confirm the accuracy of a radiation dose measurement A full reanalysis is automatically performed for every measurement yielding a dose in excess of 500 mrem 5 mSv The Luxel filter pack imaging area and the InLight imaging component renders unique filter patterns that provide qualitative information about conditions during exposure Imaging to identify static dynamic or contamination conditions is automatically performed for all beta and low energy photon measurements yielding a dose in excess of 500 mrem 5 mSv Imaging capabilities are inconclusive at energies exceeding 150 keV InLight Imaging Component Luxel Imaging Area A dynamic exposure image indicates the dosimeter was moving at the time of exposure This is verified by the blurred grid patterns in the filter pack imaging area A dynamic exposure implies that the dosimeter was worn at the time of exposure and the reported dose is valid 4 Optional Feature Reanalysis or Imaging at Less than 500 mrem 5 mSv Reanal
45. valent Reported Measurement Photon x or gamma ray 5 keV to 40 MeV 1 mrem 10 uSv 1000 rem 10 Sv Beta particle 150 keV to 10 MeV Expressed 10 mrem 100 uSv 1000 rem 10 Sv as average energy Neutron Fast optional CR 39 40 keV to 40 MeV 20 mrem 200 uSv 25 rem 250 mSv Neutron Thermal Intermediate Fast 0 25 eV to 40 MeV 10 mrem 100 uSv 25 rem 250 mSv optional CR 39 Accreditations Approvals Licenses O NVLAP NVLAP Lab Code 100518 0 for Whole Body ANSI HPS N13 11 2009 in subcategory General in all categories including VIA when the fast neutron component is added and for extremity ANSI HPS N13 32 2008 No accreditation is available from NVLAP for thermal neutron dosimeters O CNSC Canadian Nuclear Safety Commission Dosimetry Service License CJ HSE Health and Safety Executive United Kingdom approved for Whole Body OSL and Whole Body Neutrons InLight amp Administrative Features InLight s design incorporates on the face of the dosimeter your account name the participant name and a dosimeter placement icon indicating correct placement of the dosimeter The frequency color area changes in color with each exchange frequency Labels may be vertical or horizontal 31 Landauer Service Guide Account Line 1 2 123456 Subaccount Series Color Area Name Line 1 Name Line 2 Account Line 1 Account Line2 123456 s piso InLight Systems LANDAU y also Name Line 1
46. ysis or imaging at doses less than 500 rem 5 mSv can be requested Imaging is not available for doses less than 50 mrem 500 uSv After reanalysis and or imaging a note will appear at the bottom of the dosimetry report indicating O The second read agrees with the reported dose C The exposure was static dynamic or indicates contamination O An angular exposure is apparent C The dosimeter was partially shielded C The reported dose is the best possible evaluation CJ No evaluation is possible 34 Landauer Service Guide Neutrak amp Dosimeter Specifications The Neutrak detector is a CR 39 allyl diglycol carbonate based solid state mp 7 1 nuclear track detector that measures exposure due to neutrons It is not m 7 106015 sensitive to x beta or gamma radiation and can be sealed inside the Luxel Way s CR 39 dosimeter plastic blister pack in a one piece design the InLight holder in a S Fast Neutron one piece design or can be packaged specifically for neutron detection only The CR 39 is laser engraved for permanent identification to assure chain of custody E CR 39 The fast neutron option uses a polyethylene radiator for fast neutrons that e Fast Intermediate A a 3 p Th IN records recoil protons resulting from neutron interactions in the dosimeter The mn thermal intermediate neutron option has a dosimeter design intended for fast intermediate and thermal neutrons The left area of the chip uses a polyethyle

Download Pdf Manuals

image

Related Search

Related Contents

omRon 形D4NS-SK30 0686729-9B セーフティドアスイッチスライドキー  Samsung 460EX Lietotāja rokasgrāmata  Samsung Galaxy  Onkyo D-77NE Owner's Manual  ZTE CDMA 1X Card User Guide  DE Bedienungsanleitung GB User`s manual FR Manuel d`utilisation  Controlador de Aquecimento HCC 5  MH Fluid Cooler User Manual  Istruzioni per l`uso  Elect Online  

Copyright © All rights reserved.
Failed to retrieve file