1. Intel Socket 2011 1366 1156 1155 775 CPUs AMD Socket FM2 FM1 AM3 AM3 AM2 AM2 CPU amp APUs To ensure safe and easy installation please read the following precautions www ZALMAN com lJ 1 Precautions 1 Avoid inserting objects or hands into the fan while it is in operation to prevent product damage and injuries 2 Do not ingest the Thermal Grease and avoid its contact with skin and eyes If contact is made with skin wash off with water If ingested or irritation persists seek medical attention To prevent possible injuries gloves must be worn while handling this product Excessive force exerted on the fan may cause damage to the fan and or system Use and keep the product away from reach of children Check the components list and condition of the product before installation If any problem is found contact the retailer to obtain a replacement 7 Zalman Tech Co Ltd is not responsible for any damaged due to overclocking 8 During transportation of the system the cooler must be removed Zalman is not responsible for any damages that occur during the transport of a system 9 Product design and specifications may be revised to improve quality and performance 3 4 5 6 Disclaimer Zalman Tech Co Ltd is not responsible for any damages due to external causes including but not limited to improper use problems with electrical power accident neglect alteration repair improper installation or imprope
2. position aW AN caution When connecting be careful not to use the wrong size bolt The silver bolt A and B are very similar in appearance thus Silver Bolt A 4mm Silver Bolt B 3mm causing confusion Socket 2011 Socket 1366 1156 1155 775 AMD WWW ZALMAN COM a Connect the coolers 4 pin connector to the motherboard s CPU Fan header le D Z caution After installing be sure to activate the PWM control mode in BIOS on D a I M the motherboard ees pun F Optional Fan Installation Optional x To install an optional fan you should purchase it separately Hang the fan clips on the housing hole of the optional fan and on the grooves at the end of both pins of the cooler You can install a maximum of two 140 mm fans Option Fan ZM F4 One Optional Fan Two Optional Fan WWW ZALMAN COM ipo
3. Backplate and remove the Tier of the Loading Block and attach it to Double sided Tape s Cover the Backplate Double sided Loading Block Attach Double sided Tape to the Loading Block and remove the Double sided Tape Cover Double sided A Caution Please make a note of the orientation of the Loading Block WWW ZALMAN COM e D Backplate Installation x Intel Socket 2011 Installation does not require the Backplate Align the Backplate s nuts with motherboard s clip support holes attach it to the back side of the motherboard Take away the fixed Clip support from the motherboard Align the Backplate with motherboard s clip support holes attach it to the back side of the motherboard WWW ZALMAN COM E Cooler Installation Apply a suitable amount of the included Thermal Grease on the CPU s surface a Intel or AMD CPU Place the bolt on the connection position of the clip A adjust the bolt slightly and then fasten it with a Spanner Use the designated bolts for each socket AMD Socket Intel Socket 775 Intel Socket 1156 1155 a Intel Socket 2011 1366 m Silver Bolt A 4mm Socket 2011 a P Tip Silver Bolt B 3mm Socket 1366 1156 1155 775 To install easily place the bolt at the end of AMD the Spanner and align it with the connection
4. g to a user socket as shown in the image Slightly loosen the bolts insert the clip A between the cover and the base and then fasten it with the bolt ISS fa O S A Caution Please note that the connection A B H A Intel Socket AMD Socket directions of the clip A are different Installation installation according to sockets A Caution Make sure that the holes of the clip A are attached to the raised parts of the base cover WWW ZALMAN COM B Nuts and Side Caps x Intel Socket 2011 Installation does not require the Nuts and Side caps Install Bolts to the Backplate according to the Socket Type and secure with Side Caps Intel Socket 1156 1155 Intel Socket 1366 Install Bolts to the Backplate according to the Socket Type and secure with Side Caps AMD Socket A Caution Intel Socket Please note the insertion directions of the nut and side cap A Caution AMD Socket Please note the insertion directions of the nut and side cap WWW ZALMAN COM C Double sided Tape and Loading Block Installation X Intel Socket 2011 Installation does not require the Double sided Tape and Loading Block X Intel Socket 1366 1156 1155 Installation does not require the Loading Block Attach Double sided Tape to the Remove the Sticker Cover from the Lower center of the
5. r testing J 2 Specifications ea 140 L x 126 W x 159 3 H mm Long Life Bearing EE 950 1 350rpm 10 17 21dBA 10 Thermal Grease ZM STG2M Temperature Range 40 C 150 C 40 F 302 F WWW ZALMAN COW UJ 3 components Cooler EALAR Nuts CLEE Side Caps S 2 Loading Block Double sided Tape Manual Backplate Manual Eole Clip B Optional Fan FFF 9999F Silver Bolts A 4mm Silver Bolts B 3mm Socket 2011 Socket 1366 1156 1155 775 AMD 7 r Ce m J co Thermal Grease ZM STG2M Spanner WWW ZALMAN COM J 4 installation Requirements 1 Space Requirements The cooler s installation requires an unobstructed space of 140mm length 126mm width and 160mm height with the CPU as a central reference point Please check if components such as ODDs and PSU protrude into the required space 2 Air Guide Removal Air guides on enclosures must be removed before the cooler s installation since they protrude into the cooler s required space Case Cover 3 Cooler Orientation Install the cooler s fan bracket close to the rear fan of the case so that the air passing through the cooler comes out through the rear fan of the case as shown in the image Case Exhaust Rear Fan MotherBoard Fan Bracket WWW ZALMAN COM Q 5 Installation A Clip A Installation Install the clip A accordin