Contents
1. cr NUMBER Record Count 4 Bytes Width 0000h 0080h EXAMPLE A 0006 14 Od The Total of Record Count 12 2 READ RECORD BY NUMBER E gt Ds T s wwwseeR cR 7 TNuwsERT DATA NUMBER Record Count 4 Bytes Width 0000h 007Fh DATA Record Data TRACK1 TRACK2 TRACK3 EXAMPLE ez s ooos 94 ez 2 2222 3333 04 Read Record Number 11 TRACK1 ID ABCD TRACK2 ID 2222 TRACK3 ID 3333 3 ERASE ALL RECORD E E Ese TI EXAMPLE a pe E Peas ERASE ALL RECORD MiniDX4 User s Manual Rev A 4 SET DATE AND TIME E EST s T vvvyywwbbhhmmssw Year 1980 20xx Second 00 59 EXAMPLE Set Date 2000 5 5 Set Time 12 30 00 Friday 5 GET DATE AND TIME E B EXAMPLE g Get Date 2000 11 8 Get Time 14 20 31 Wednesday 6 GET PRODUCT VERSION E 8 5 VxxRmm Firmware Version x x Rmm Modify mm Times EXAMPLE a voro 94 Firmware Version 1 0 Modify times 0 MiniDX4 User s Manual Rev A 7 SET REGISTER xj _STX C REGISTER PARAM CHKSUM CR 9 oe REGISTER Register Address 2 Bytes Width 00h FFh PARAM CHKSUM C REGIST
2. Memory Low Warning Log database memory is almost full 29096 Adding new records 15 still possible but you are advised to free up the log database memory by uploading the data to the PC as soon as possible 8 Memory Full Warning Log database memory is full You not be able to add any new records Free the log database memory by uploading the data to the PC 9 Firmware Management mode FMM FMM allows you to quickly upgrade your MiniDX4 s internal firmware via com port and also check validity of currently loaded firmware Contact your dealer for most recent firmware upgrade files MiniDX4 User s Manual Rev A Card Data Format CARD DATA STRING TRACK 1 TRACK2 TRACKS ODATERTME ss RRR RCSA 5 BAR s WE sr we TRACK 1 Track 1 IATA Bits Per Inch E 1 SS is the start sentinel Bits Per Character 2 ES is the end sentinel 7 Alphanumeric Characters 79 3 Card Id up to 76 alphanumeric data characters Alphanumeric Characters 79 TRACK 2 Track 2 ABA Bits Per Inch 1 SS is the start sentinel Bits Per Character 2 ES is the end sentinel Numeric Characters 3 Card Id up to 37 numeric data characters TRACK 3 CARD ID Track 3 Thrift Bits Per Inch 20 1 SS is the start sentinel Bits Per Character TE 2 ES is the end sentinel Numeric Characters 3 Card Id up to 104 numeric data characters DAT
3. 94 B Write to Parameter Table Address 30h TRACK ACTIVE MODE TRACK 1 ENABLE 7 6 SET POWER SAVE MODE E lt Trowersave TT move T er o DISABLE 00 FE ENABLE EXAMPLE E 52 71 pon g Write to Parameter Table Address 1E h Power Save Mode Power Save Mode Disable p MiniDX4 User s Manual Rev A 8 GET REGISTER xo kor S Taran REGSTER Register Address 2 Bytes Width 00h FFh PARAM Set Parameters of Register 8 1 GET POWER MODE SX 12 j LLSTX MODE CHKSUM CR Same 7 1 SET POWER MODE EXAMPLE os Te 9 Goma Pon Write to Parameter Table Address 12h Get Power Mode Real Control 8 2 GET AUTO POWER OFF TIME LOW BYTE E1513 I Esx se Tae Same 7 2 SET AUTO POWER OFF TIME LOW BYTE EXAMPLE g 2 Get Parameter From Parameter Table Address 10h Auto Power Off Time Period Low Byte 5 Seconds MiniDX4 User s Manual Rev A 8 3 GET AUTO POWER OFF TIME HIGH BYTE Gece 1 D seca T cesso cr Same 7 3 SET AUTO POWER OFF HIGH BYTE EXAMPLE es Get Parameter From Parameter Table Address 11h Auto Power Off Ti
4. Interface RS232 Half Duplex 8N1 9600 bps USB Interface Full compliance with the USB Specification V 1 1 The device uses a Virtual Serial Port Driver making it appear to have the software like a standard RS232 Serial Port CLOCK Real Time Clock RTC module and back up capacitor Memory Size for Storing Data CMOS Serial Flash Memory 512K bytes Up to 2048 records 256 Bytes Record Battery Power Rechargeable Lithium ion Polymer Battery Nominal Capacity 250 mAH Typical Nominal Voltage 3 7 V Cycle Life 300 cycles at least Low Battery Detect and Built in Quick Charge Circuit Power Supply for Charge DC 5V 200mA for RS 232 or USB Powered Charging duration time 1 5 2 5 hr Working duration time after charge 48 hr always power on Environment Operating Temp 0 C 60 C Discharge 45 C Charging Storage Temp 10 65 C Humidity 10 90 relative Dimensions L78 x W20xH26 5 mm Mounting Portable or Any surface MiniDX4 User s Manual Rev A Display Information Operational Indicator Take turns blink Power On 2 times Auto Power Off Take turns blink 2 times Blink Firmware Management mode Battery Indicator Take turns blink Power On E 2 times Precharge in progress om Slow Blink Charge suspend temperature Timer Fault Fast Blink Inactive Battery Take turns blink 2 times MiniDX4 User s Manual Rev A Op
5. E amp TIME amp WEEK DATE 52 TIME 5 WEEK 1 SP is the SPACE characters 20h 2 TIME is 24hr MiniDX4 User s Manual Rev A Communication Protocol Packet Format C STX CMD CONTENTS CHKSUM CR STX REPLY CONTENTS CHKSUM CR ITEM Dec Hex Control Key Function CMD Asi Ascii Command Code CONTENTS Asi Asi Contents Data CHKSUM sci Asi o o cr i3 0d Command Index Table Topic Command Contents Description o logo four digit password Set Password 2 Serete O eeProdutVersin GeDateandTime Set Number oF Record DATABASE Number by Number O OO Reply Index Table Topic Reply Contents Description __ ACK Reply Information ACK Information NAK N See Error Index Table NAK Information Error Index Table For Reply NAK Topic Error Index Description C LACCESS LEVEL Denied or Password Error Command packet is too ong COMMAND CODE 02 Command packet is empty 03 Command code is out of range Memory Not Enough Action Failure DATABASE 07 Check Sum Error 09 0 File Not Exist MiniDX4 User s Manual Rev A 1 GET NUMBER OF RECORD
6. ER PARAM 7 1 SET POWER MODE os gt one J eson Real Control O1 FE Auto Power OFF Always Power ON EXAMPLE amp gt 52 12 32 94 B lt Write to Parameter Table Address 12 h Set Power Mode Real Control CHKSUM 43h C 31h 1 32h 2 2Ch 30h 0 30h 0 132h 33h 3 32h 2 7 2 SET AUTO POWER OFF TIME LOW BYTE Oo _ c 10 CHKSUM CR g SECL OOh FFh 0 255 2 Second EXAMPLE m 0 TT 41 ode ga Write to Parameter Table Address 10h Auto Power Off Time Low Byte 5 Seconds 10 MiniDX4 User s Manual Rev A 7 3 SET AUTO POWER OFF TIME HIGH BYTE Oo o TR Gora Ic SECH 00 FF 00 FF 2 256 Seconds EXAMPLE TT 2 94 a Write to Parameter Table Address 11 h Auto Power Off Time High Byte 2 2 256 Seconds 7 4 SET BUZZER ON OFF T BUZZER OFF x 022 EXAMPLE a g Write to Parameter Table Address 19 h xx any value T MiniDX4 User s Manual Rev A 7 5 SET TRACK ACTIVE MODE STX TRACK MODE CHKSUM CR og TRACK TRACK 1 ENABLE TRACK2 709 DISABLE TRACKS REQUIRED EXAMPLE E se
7. MinIDX4 Portable magstripe reader with rechargeable Battery User s Manual Revision A 2010 01 06 MiniDX4 User s Manual Rev A a MiniDX4 b CD ROM c Chain Sling d USB Cable Trademark All brand and product names are trademarks or registered trademarks of their respective companies statement Manual and manual content such as are subject to change without notice This company does not warrant that the manual content Between the product and the manual for any errors omissions or differences which directly or indirectly caused damage the company will not be responsible for compensation Note This manual display screen pictures and other pictures for reference only and the actual product may vary MiniDX4 User s Manual Rev A Connections 3 OPC rational ISS Ci MON 5 Card MERCI NOPHOTO 6 Commamcoadob 7 FCC COMPLIANCE STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicat
8. e Red Green LED take turns blinking this means the RTC is malfunctioning and you must do the RTC time setting before you use the unit 4 Low Battery Detect When powered by battery it would have Low Battery Detect function When the battery goes low the LED would flash green once every 2 second and you must charge battery immediately otherwise the unit would shut down any time without pre warning 5 Charge Mode There are three different charge modes for MiniDX4 low battery mode real time mode and manual charge mode Low battery charge mode is used when the battery hits low voltage it starts to be charged automatically Real time charge mode is whenever the MiniDX4 cable is connected to USB or Power adapter it would be charged immediately Manual charge mode is the charge 15 controlled by Demo software User can use the software to start or stop charging 6 Charge Status Indication When MiniDX4 is in charge Battery Status Indicator light show slow blink red that means the battery 15 in the pre charge When Battery Status Indicator light turns to red it means the battery 15 in charge status When Battery Status Indicator light turns to green it means the charge is finished If the charge process has unusual situation Battery Status Indicator light will show red fast blink If MiniDXA cable is connected and battery is not in charge Battery Status Indicator light will turn off The default set mode is on low battery charge mode 7
9. erational Description 1 Powered by Battery For normal use the unit is powered by battery Push the Power Switch Button for about 1 5 seconds to turn on the unit Also push the Power Switch Button for about 1 5 seconds to turn off the unit After the unit is turned on the power would be turned off automatically if there is no swiping a card on the unit in 30 seconds This means the unit would be turned off if no swiping a card again in every 30 seconds after every card swiping It would have Low Battery Detect Warning indication when the unit is powered by battery 2 Powered by Cable When the unit is connected with the PC through the communication Cable and the PC is running MiniDX4 software and open the COM PORT for the unit then the unit will be turned on in about 0 5 second by the PC through the RS 232 COM PORT Then you can do the unit Setting Configuration or data downloading When the software closes the COM PORT or exits the power turn off from the PC immediately When powered by cable from PC the Power Switch would have no function and the unit would have no Low Battery Detect Warning function 3 Real Time Clock Setting Before start using the unit you must set the Real Time Clock RTC inside the unit to your local time If there is no battery for quite a while or it is powered by cable for quite a while this would cause Real Time clock RTC malfunctioned due to no power supply When put on the battery to turn on the unit and th
10. ion Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Read the instructions on your device before installing batteries 1 Insert batteries into your device properly with the and terminals aligned correctly 2 Always fully charge your batteries before use 3 When you charge the batteries for the first time or if the batteries have been stored for a long time it normally takes about 3 charge and discharge cycles for the batteries to regain full capacity 4 Itis normal for batteries to become hot during charging and they will gradually cool down to room temperature after fully charged 5 Store the batteries in a cool and dry place 6 Remove batteries from the electrical device if the device is not going to be used for a long time 7 Keep battery contact surfaces and battery compartment contacts clean by rubbing them with a clean pencil eraser or a rough cloth each time you replace batteries 8 If the performance of the batteries decrease substantially it is time to replace the batteries 9 Keep batteries away from children If swallowed contact a physician at once MiniDX4 User s Manual Rev A Specifications Magnetic Stripe Card TRACK 1 210 79 Alphanumeric Characters TRACK2 ABA 75 bpi 40 Numeric Characters TRACK 3 Thrift 210 bpi 107 Numeric Characters RS232
11. me Period High Byte 2 256 2 Seconds 8 4 GET SOUND MODE Geos B EXAMPLE a Get Parameter From Parameter Table Address 19h SOUND MODE ENABLE 8 5 GET TRACK ACTIVE MODE E mc oe Ex T cR TRACK 1 TRACK2 TRACKS EXAMPLE os ET re Get Parameter From Parameter Table Address 30h TRACK 1 ACTIVE MODE ENABLE a Jaa MiniDX4 User s Manual Rev A 9 LOGIN _ SIX L PASSWORD CR PASSWORD 4 Characters for Login 0000 7 Initial value ooo o m a Login password 0000 10 LOGOUT g EXAMPLE 11 SET PASSWORD Emp Password cuksuw eR N a PASSWORD New four digit password EXAMPLE r HEN 1234 EST T9 Set new password 1234 15