NT31/631 Multi-Vendor connection, Operation Manual

image

Contents

1. 50 5 4 Siemens Custom Cable Requirements a 50 Use with Modicom PLG8S Ea epar 53 6 1 Configuring NT31 631 for Modicon 54 6 1 1 Connecting NT31 631 to Modicon TSX Micro or 54 6 1 2 Connecting NT31 631 to Modicon TSX 56 6 2 Configuring NT31 631 for Communication with Modicon PLCs 57 6 3 Allocation Area Table for Modicon 5 59 6 4 Modicon Custom Cable Requirements r rrsssssssssssse 59 Error Messages and Troubleshooting 61 Error Messages and Troubleshooting sss nnne 62 Siemens Error Messages and Troubleshooting sssssssssssseeeeeennn 63 Siemens PEG Error Codes uu uu ee ree P ee deve eite Aaa dv tree gas 64 Siemens HMI Adapter Error 65 Address Conversion Table U u u 67 Address Conversion Table EE Ene eee erae des 68 INDEX ec
2. 4 Select Memory Switch The Memory Switch screen appears See Figure 5 5 Figure 5 5 Memory Switch screen 1 4 MEMORY SWITCH AH 1 4 Key Press Sound ON Printer Controller ESC P Print Method Tone Abort 5 Press the down arrow next screen or the up arrow previous screen touch switch until the fourth memory switch screen appears When you reach the fourth screen 4 4 displays in the upper left corner of the PT Port B is the default port for communication between the PT and PLC Prodave HMI displays to the right of the Comm B Method touch switch Select Max MPI Address based on the maximum PLC and PT address Maximum MPI address must be greater than PLC and PT MPI address See Figure 5 6 To use port B skip to step 7 48 Figure 5 6 Memory Switch screen 4 4 Comm B Method MEMORY SWITCH gt Ally 4 4 Comm A Method None Comm B Method Prodave HMI Set Max MPI Addr 15 6 Touse port A press the Comm A Method touch switch until Prodave HMI is shown to the right of the touch switch Press the Comm B Method touch switch until it displays None Select Max MPI Address based on the maximum PLC and PT address Maximum MPI address must be greater than PLC and PT MPI address See Figure 5 7 Figure 5 7 Memory Switch screen 4 4 Comm A Method aly 4 4 Comm A Method Predave HMI Comm B Method None Max MPI Addr 7 Press the MPI touch switch to display the MPI Address
3. 24 Connect to Allen Bradley SLC 5 03 5 04 and SOT sieh Laden leute eee gs 25 Connect to GE Fanuc 90 30 with CCM Module P 37 Connect to GE Fanuc with Built in Serial Port 36 Connect to Modicon TSX Micro or Premium 53 Connect to Modicon TSX Quantum 55 Connect to Siemens 57 300 and S7 400 46 Prepare for Software Installation with System Irnistaller y u aa mec 4 NT series System Installer Exiting iier 9 Installing the System 9 Startifig e 3 ciao 6 71 72 NTST Setup Access Configuration Screen 12 Choose the PT and PLC Vendor 13 Configure for Allen Bradley GE Fanuc or Siemens PLCS esee 12 denne ahua aypaq 3 PT Models ener 3 Siemens Addressing eee 50 Configure NTST a u 13 Connecting 1 631 46 T w Control Notify 18 Custom Cable Requirements 50 CMM Module nsss naani iis 50 HMI Adapter 3 46 48 50 62 64 System Overview eene 2 System Requirements 3 TroubleshootingSee Error Messages and Troubleshooting Word Addressing See Addressing Revision History A manual revision code appea
4. 5 1 Configuring NT31 631 for Siemens This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Siemens PLCs Note Do not use 9 to 9 pin cable with 9 to 25 pin adapter when connecting the cable to 25 pin port on the PT 5 1 1 Connecting NT31 631 to the Siemens S7 300 and S7 400 PLCs To connect the NT31 631 to the Siemens S7 300 and S7 400 PLCs you need the following equipment e 57 300 or S7 400 PLC e Siemens HMI Adapter e NT31 631 PT with serial cable to connect PT and HMI adapter please see Section 5 4 for more information about using the appropriate cable To connect NT31 port B to Siemens S7 300 or S7 400 with HMI Adapter 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 9 pin end of the cable to the Siemens HMI Adapter 3 Connect the HMI Adapter to the MPI port on the S7 300 or S7 400 PLC To connect NT631 Port A or B or NT31 to Siemens 57 300 or S7 400 PLC 1 Connect the 9 pin cable male end to the 9 pin port of the NT31 631 port B is default 2 Connect the 9 pin cable female end to the Siemens HMI Adapter 3 Connect the Siemens HMI Adapter to the MPI port on the 57 300 or 57 400 Series PLC To configure MPI port on the Siemens e Set MPI port address on Siemens PLC Default is 2 using Siemens PLC programming software The MPI port address depends on PLC system PT memory switch PLC MPI Address must match PLC MPI port addres
5. All selected information appears on the Configuration screen You now configure the PLC address on the Control Notify Area tab See Section 2 2 The following table specifies what is available for which PT Model lt 2 Allen Bradley 2 GE Fanuc 2 Modicon NT31 31C 631 631C V2 System Ver 3 1 2 Siemens NT31 31C 631 631C V1 System Ver 2 1 2 Mitsubishi A 2 2 Mitsubishi Fx 2 lt Memory Link NT31 31C 631 631C V1 NT31 31C 631 631C NT30 30C NT620C 620S NT 625C NT600S NT20S NT11S 2L Omron Y supported Font type and NT30 620 Compatible Mode When one of NT31 31C 631 631C V2 System Ver 3 1 is selected as PT Model Font Type and NT30 620 Compatible Mode will be activated Please refer to NT series Support Tool for Windows Ver 4 1 Operation Manual V061 E1 L1 for details 13 2 2 Setting the Control Notify Area 2 2 Setting the Control Notify Area After you configure NTST to use the desired PLC you configure the addressing through setting the Control Notify Area You use the Control Notify Area to allocate PLC memory to the PT which allows the PT and PLC to exchange data NT31 631 requires five words of Control Area and two words of Notify Area within PLC memory For V1 Model PTs the Window Control Area is available and requires nine words This area is used exclusively by the PT The words
6. ii repair the non complying Product or iii repay or credit Buyer an amount equal to the purchase price of the non complying Product provided that in no event shall Omron be responsi ble for warranty repair indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were prop erly handled stored installed and maintained and not subject to contamina tion abuse misuse or inappropriate modification Return of any Products by Buyer must be approved in writing by Omron before shipment Omron Compa nies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components circuits system assemblies or any other materials or substances or environ ments Any advice recommendations or information given orally or in writing are not to be construed as an amendment or addition to the above warranty See http www omron247 com or contact your Omron representative for pub lished information Limitation on Liability Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Product on which liabil
7. 03 5 04 and 5 05 To connect the NT631 to the Allen Bradley SLC 5 03 5 04 and 5 05 you will need the following equipment e Allen Bradley SLC 5 03 5 04 or 5 05 PLC e NT31 631 PT with serial cable to connect PT and PLC please see Section 3 4 for appropriate cable To connect NT31 port B to Allen Bradley 5 03 5 04 and 5 05 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 9 pin end of the cable to the RS232 port on CPU connect NT631 port A or B or NT31 port A to Allen Bradley 5 03 5 04 and 5 05 1 Connect the 9 pin cable male end to the 9 pin port of the NT31 631 port B is default 2 Connect the 9 pin cable female end to the RS232 port on the CPU configure Allen Bradley 5 03 5 04 and 5 05 RS232 port 1 Set the module for full duplex BSC Set the module for embedded response Set detect for automatic Disable duplicate packet detect Set the baud rate for 9600 19200 or 38400 Shi rd co Figure 3 3 Connecting NT31 to Allen Bradley 5 03 5 04 and 5 05 Allen Bradley NT 31 PT SLC 5 03 5 04 5 05 PLC RS 232 25 to 9 pin Or 9 to 9 pin 25 3 1 Configuring NT31 631 for Allen Bradley Figure 3 4 Connecting NT631 to Allen Bradley 5 03 5 04 and 5 05 Allen Bradley NT 631 PT SLC 5 03 5 04 5 05 PLC 3 1 3 Connecting NT31 631 to Allen Bradley PLC5 To connect the NT31 631 to the Allen Bradley PLC5 you will need the following equipment 1
8. 2 3 PLC Address screen for Allen Bradley PLC Address 3 Use the necessary addressing fields to specify the start address of the Control Area 4 Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing Control Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the PT Control Area group box 15 2 2 Setting the Control Notify Area set the Notify Area for Allen Bradley I Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 2 Click on the Set button in the PT Notify Area group box The PLC Address screen appears See Figure 2 3 Use the necessary addressing fields to specify the start address of the Notify Area Note The start address of Notify area must be at least five words apart from start address of the Control Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing Notify Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the PT Notify Area group box Click OK on the Control Notify Area screen A new application window opens and you are ready to create your screen data 2 2 2 Setting the Control Notify Area for GE Fanuc 16 This section lists the steps necessary to set the Control Notify Area in NTST for GE Fanuc PLCs This section
9. Allen Bradley PLC5 11 PLC5 20 or PLC5 20C 2 NT31 631 PT with serial cable to connect PT and PLC please see Section 3 4 for appropriate cable To connect NT31 port B to Allen Bradley 5 11 5 20 and 5 20C 1 Connect the 25 pin cable to port B of the NT31 2 Connect the another 25 pin end of the cable to the RS232 port on CPU To connect NT631 port A or B or NT31 port A to Allen Bradley 5 11 5 20 and 5 20C 1 Connect the 9 pin cable male end to the 9 pin port of the NT31 631 port B is default 2 Connect the 25 pin cable female end to the RS232 port on the CPU configure Allen Bradley 5 11 5204 and 5 20C RS232 port 1 Set the module for full duplex BSC Set Embedded Response Detect of PLC5 for Automatic Mode Disable duplicate packet detect Set Error Checking for BCC Set the baud rate for 9600 19200 or 38400 9 to 9 pin 209 ipo Figure 3 5 Connecting NT31 to Allen Bradley 5 11 5 20 and 5 20C Allen Bradley NT 31 PT PLC 5 11 5 20 5 20C RS 232 25 to 25 pin Or 9 to 25 pin 26 Figure 3 6 Connecting NT631 to Allen Bradley 5 11 5 20 and 5 20C Allen Bradley NT 631 PT PLC 5 11 5 20 5 20C RS 232 3 1 4 Connecting NT31 631 to Allen Bradley MicroLogix 1000 1200 and 1500 To connect the NT631 to the Allen Bradley MicroLogix 1000 1200 and 1500 you will need the following equipment 1 Allen Bradley MicroLogix 1000 1200 or 1500 2 NT31 63
10. Connecting NT31 631 to Allen Bradley SLC 5 03 5 04 and 5 05 25 3 1 3 Connecting NT31 631 to Allen Bradley PLCS u 26 3 1 4 Connecting NT31 631 to Allen Bradlley MicroLogic 1000 1200 and 1500 27 3 2 Configuring NT31 631 for Communication with Allen Bradley PLCs 29 3 3 Allocation Area Table for Allen Bradley PLGs 31 3 4 Allen Bradley Custom Cable Requirements 31 3 4 1 Custom Cable for SLC95 uu aaa errem nennen nennen nnns 31 3 4 2 Custom Cable tor PLCS 32 3 4 3 Custom Cable for MicorLogiXx eene enne 33 23 3 1 Configuring NT31 631 for Allen Bradley 3 1 Configuring NT31 631 for Allen Bradley This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Allen Bradley PLCs Note Do not use 9 to 9 pin cable with 9 to 25 pin adapter when connecting the cable to 25 pin port on the PT 3 1 1 Connecting NT31 631 to Allen Bradley SLC 5 02 To connect the NT31 631 to the Allen Bradley SLC 5 02 you need the following equipment e Allen Bradley SLC 5 02 PLC e 1747 KE Communication Module with 1747 C13 cable provided by Allen Bradley e NT31 631 PT with serial cable to connect PT and PLC please see Section 3 4 for appropriate
11. Connecting NT31 to GE Fanuc with CMM Module GE Fanuc CMM Module NT 31 PT 90 30 with CMM Module 25 to 25pin 37 4 1 Configuring NT31 631 for GE Fanuc 38 Figure 4 6 Connecting NT631 to GE Fanuc with CMM Module NT 631 PT 9 to 25 pin CMM Module GE Fanuc 90 30 with CMM Module 4 2 Configuring NT31 631 for Communication with GE Fanuc PLCs GE Fanuc PLCs communicate to NT31 631 using the SNP protocol This section describes setting the memory switches on the PT for use with GE Fanuc PLCs You can configure Port A or Port B on the PT for communications with GE Fanuc PLCs To Configure NT31 631 communication for GE Fanuc 1 Start the PT 2 Press two corner keys on the PT at the same time to enter the System Menu The System Menu screen appears See Figure 4 7 Figure 4 7 System Menu SYSTEM MENU Transmit Mode Expansion Mode 3 Select Maintenance Mode The Maintenance Mode menu screen appears See Figure 4 8 Figure 4 8 Maintenance Mode Menu MAINTENANCE MODE MENU Quit PT Settings Memory Init Display History Memory Switch Alarm History LCD Settings Screen Data Disp Calendar Check IO Check 4 Select Memory Switch The Memory Switch screen appears See Figure 4 9 Figure 4 9 Memory Switch screen 1 4 MEM
12. Port B skip to step 7 29 3 2 Configuring NT31 631 for Communication with Allen Bradley PLCs Figure 3 12 Memory Switch screen 4 4 Comm B Method MEMORY SWITCH PH 4 4 Comm A Method e Comm B Method pr1 rs232 1 1 6 To use port A press the Comm A Method touch switch until DF1 RS 232 1 1 is shown to the right of the touch switch Press the Comm B Method touch switch until it displays None See Figure 3 13 Figure 3 13 Memory Switch screen 4 4 Comm A Method MEMORY SWITCH Ad 4 4 Comm A Method DPF1RS232 1 1 Set Comm B Method None 7 Press the Set touch switch to the right of the selected Comm Method touch switch A screen displays with settings for the selected port See Figure 3 14 Figure 3 14 Memory Switch Comm Port Settings MEMORY SWITCH Comm Port A DFI RS232 1 1 Comm 8 bits its Speed 9600 bps Error Check 8 Press each touch switch until the desired setting displays The setting option changes each time the touch switch is pressed Note You may only use 9600 or 19200 for communication between Allen Bradley and NT31 631 CRC cannot be used as Error Check for communication with MicroLogix 1500 9 Press the Quit touch switch twice The Maintenance Mode Menu screen displays The communication port and speed settings are saved 10 Press the O Check touch switch then the F check touch switch and then Comm Port A or Comm Port B to confirm com
13. TSX Micro or Premium RS 422A Modicon NT 631 PT TSX Micro or Premium Ha 55 6 1 Configuring NT31 631 for Modicon 6 1 2 Connecting NT31 631 to Modicon TSX Quantum To connect the NT31 631 to the Modicon TSX Quantum you will need the following equipment e Modicon TSX Quantum PLC e NT31 631 PT with serial cable to connect PT and PLC please see Section 6 4 for appropriate cable connect NT31 port B to Modicon TSX Quantum 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 9 pin end of the cable to the Modbus port on the TSX Quantum connect NT631 port A or B NT31 port A to Modicon TSX Quantum 1 Connect the 9 pin cable to the 9 pin port of the NT31 631 port B is default 2 Connect the other 9 pin end of the cable to the Modbus port on the TSX Quantum To configure the Modbus port S6 1 Configure Modbus port setting in a support software for TSX Quantum Set the baud for 9600 or 19 200 Set the mode for RTU Set the Stop for 0 or 1 Set the Parity for none odd or even eh e eS Figure 6 5 Connecting NT31 to Modicon TSX Quantum NT 31 PT Modicon TSX Quantum 25 to 9 pin Or 9 to 9 pin 6 2 Configuring NT31 631 for Communication with Modicon PLCs Modicon PLCs communicates to NT31 631 using the Modbus protocol
14. This section describes setting the memory switches on the PT for use with Modicon PLCs You can configure Port A or Port B on the PT for communications Modicon PLCs To Configure NT31 631 communication for Modicon 1 Start the PT 2 Press two corner keys on the PT at the same time to enter the System Menu The System Menu screen appears See Figure 6 6 Figure 6 6 System Menu SYSTEM MENU Expansion Mode 3 The Maintenance Mode menu screen appears See Figure 6 7 Figure 6 7 Maintenance Mode Menu MAINTENANCE MODE MENU Quit PT Settings Memory Init Display History Memory Switch Alarm History LCD Settings Screen Data Disp Calendar Check VO Check 4 Select Memory Switch The Memory Switch screen appears See Figure 6 8 Figure 6 8 Memory Switch screen 1 4 MEMORY SWITCH PH Key Press Sound ON Buzzer Sound OFF Printer Controller ESC P Print Method Tone Abort 5 Press the down arrow next screen or the up arrow previous screen touch switch until the fourth memory switch screen appears When you reach the fourth screen 4 4 displays in the upper left corner of the PT Port B is the default port for communication between the PT and PLC Modbus displays to the right of the Comm B Method touch switch To use port B skip to step 7 57 6 2 Configuring NT31 631 for Communication with Modicon PLCs Figure 6 9 Memory Switch screen 4 4 Comm B Method M
15. cable To connect NT31 port B to Allen Bradley 5 02 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 9 pin end of the cable to the DF1 RS232 port on the 1747 KE module 3 Connect the 1747 C13 cable to the DH485 port on the 1747 KE module 4 Connect the 1747 C13 cable to the DH485 port on the Allen Bradley SLC 5 02 connect NT631 port A or B NT31 port A to Allen Bradley 5 02 Connect the 9 pin cable male end to the 9 pin port of the NT31 631 port B is default 1 2 Connect the 9 pin cable female end to the DF1 RS232 port on the 1747 KE module 3 Connect the 1747 C13 cable to the DH485 port on the 1747 KE module 4 Connect the 1747 C13 cable to the DH485 port on the Allen Bradley SLC 5 02 To configure DF1 RS232 port on 1747 KE Module 1 Set the module for full duplex BSC Set the module for embedded response Set detect for automatic Disable duplicate packet detect Set the baud rate for 9600 19200 or 38400 aon par Figure 3 1 Connecting NT31 to Allen Bradley 5 02 Allen Bradley NT 31 PT SLC 5 02 PLC CPU 25 to 9 pin Or 9 to 9 pin 1747 C13 Cable 1747 KE Communications Module 24 Figure 3 2 Connecting NT631 with Allen Bradley 5 02 Allen Bradley NT 631 PT SLC 5 02 PLC CPU 9 to 9 pin 1747 C13 Cable 1747 KE Communications 3 1 2 Connecting NT31 631 to Allen Bradley SLC 5
16. may not be used for any other purpose in the PLC program Please refer to NT series Support Tool for Windows Ver 4 1 Operation Manual V061 E1 L1 for further details You must program the first word of the Control Area with desired initial start screen number value NT31 631 recognizes 0 as a blank screen which is the typical value at first word of the Control Area If the first word is not programmed correctly you will receive a blank screen on the PT This section outlines the steps necessary to set the Control Notify Area in NTST for Allen Bradley GE Fanuc Siemens and Modicon PLCs 2 2 1 Setting the Control Notify Area for Allen Bradley 14 This section outlines the steps necessary to set the Control Notify Area in NTST for Allen Bradley PLCs This section assumes that you understand the addressing scheme used by your Allen Bradley PLC Please see your Allen Bradley user manual for assistance with addressing scheme Note You can use Allen Bradley s hand held or PC based software to allocate memory in Bit or Integer area of the PLC set the Control Area for Allen Bradley 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 2 Figure 2 2 Control Notify Area tab PT Configuration Fo SGTITTTTETI US n r 2 Click on Set button the PT Control Area group box The PLC Address screen appears See Figure 2 3 Figure
17. of connecting cable with PCMCIA card 4 Connect the other 25 pin end to port B of NT31 connect NT31 631 port A or B or NT31 port A to Modicon 90 20 or 90 30 with built in serial port Mount the connecting cable to PCMCIA card Set the PCMCIA card to PCMCIA slot on TSX Micro or Premium PLC Connect the 25 pin cable to the 25 pin end of the connecting cable with PCMCIA card 4 Connect the 9 pin cable to the 9 pin port of the NT31 631 port B is default configure PCMCIA card for Modbus 1 Configure the link of PCMCIA card for MODBUS JBUS LINK Set the type for Slave Set the transmission speed for 9600 or 19 200 Set the data for RTU 8bit Set the Stop for 0 or 1 Set the Parity for none odd or even ON enr ol Figure 6 1 Connecting NT31 to Modicon TSX Micro or Premium RS 232C Modicon NT 31 PT TSX Micro or Premium 25 to 25 pin Or 9 to 25 pin 54 Figure 6 2 Connecting NT631 to Modicon TSX Micro or Premium RS 232C Modicon TSX Micro or Premium NT 631 PT 9 to 25 pin Figure 6 3 Connecting NT31 to Modicon TSX Micro or Premium RS 422A Modicon NT 31 PT TSX Micro or Premium 25pin to wires of TSX SCP CX 4030 Figure 6 4 Connecting NT631 to Modicon
18. with 1747 KE Communications Module SLC 5 03 SLC 5 04 SLC 5 05 GE Fanuc Series 90 20 and 90 30 PLCs Series 90 20 with SNP X support Series 90 30 with built in serial port and SNP X support Series 90 30 CMM Module configured for SNP X operation Siemens S7 300 and 57 400 PLCs using Siemens HMI Adapter 57 300 57 400 CPU312 CPU412 1 CPU313 CPU413 1 CPU314 CPU413 2 CPU315 CPU414 1 CPU315 2 DP CPU414 2 DP CPU416 1 CPU416 DP Protocol the interface between NT31 631 and a Siemens PLC is provided by Prodave HMI protocol This protocol requires use of a Siemens HMI Adapter provided by Siemens Siemens Part 6ES7 972 OCA10 OXAO Modicon TSX Micro Premium Quantum PLCs Micro Premium Quantum TSX 37 21 001 TSX P57 102M 140 CPU 113 02 TSX 37 21 101 TSX P57 202M 140 CPU 113 03 TSX 37 22 001 TSX P57 252M 140 CPU 434 12 TSX 37 22 101 TSX P57 302M 140 CPU 534 14 TSX P57 352M TSX P57 402M TSX P57 452M Personal Computer Specifications listed in NT series Support Tool for Windows Ver 4 1 Operation Manual V061 E1 L1 Section 1 2 NTST version 4 2 must be installed To communicate between Personal Computer and PT available from Omron Cable Type Connector pin pin Omron Part Number Programming Cable 9 9 C200H CN229 EU Programming Cable 9 25 C200H CN220 EU 1 3 Preparing NT31 631 for Software Installation with System Installer and Downloading the System Program This section describes how to prepare the NT31 631 for Allen B
19. 1 PT with serial cable to connect PT and PLC please see Section 3 4 for appropriate cable To connect NT31 port B to Allen Bradley MicroLogix 1000 1200 and 1500 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 8 pin Mini Din end of the cable to the communication port on controller connect NT631 port A or B or NT31 port A to Allen Bradley MicroLogix 1000 1200 and 1500 1 Connect the 9 pin cable male end to the 9 pin port of the NT31 631 port B is default 2 Connect the 8 pin Mini Din end of the cable to the communication port on controller To configure Allen Bradley MicroLogix 1000 1200 and 1500 communication port 1 Use DF1 Full Duplex driver Set the baud rate for 9600 or 19 200 Set Error Checking for BCC or CRC NT31 631 only support BCC for MicroLogic1500 Set Embedded Response for Auto Detect Disable duplicate packet detect 9 to 25 pin Ch Ps code tt Figure 3 7 Connecting NT31 to Allen Bradley 5 03 5 04 and 5 05 Allen Bradley NT 31 PT MicroLogix 1000 1200 and 1500 RS 232 Figure 3 8 Connecting NT631 to Allen Bradley MicroLogix 1000 1200 and 1500 25 pin to Mini Din Or 9 pin to Mini Din 27 3 1 Configuring NT31 631 for Allen Bradley Allen Bradley NT 631 PT MicroLogix 1000 1200 and 1500 RS 232 9 pin to Mini Din 28 3 2 Configuring NT31 631 for Communication with Allen Bradley PLCs Allen
20. 71 Revision HISfOry ul P 73 viii SECTION 1 Connectable Hardware Combinations This section gives an overview of system requirements necessary to use NT31 631 with Allen Bradley GE Fanuc or Siemens PLCs In This Section 141 System OVvervieW u u a Uu u aaa aaa SAEPE 2 1 2 System Requirement u Q 3 1 3 Preparing NT31 631 for Software Installation with System Installer and Downloading the System progranm 4 1 3 1 Preparing NT31 631 for Software Installation with System Installer 4 1 3 2 Using the NT series System Installer a 6 1 3 2 1 Starting the NT series System Installer a 6 1 3 2 2 Installing the System Program U uuu 8 1 3 2 3 Exiting the NT series System Installer enne 9 1 1 System Overview 1 1 System Overview Use the NT631 and NT31 to communicate directly with Allen Bradley GE Fanuc Siemens and Modicon PLCs These operator interfaces communicate with the Allen Bradley SLC 500 family PLC5 series and MicroLogix controllers using the DF1 protocol and use the SNP X protocol to communicate with GE Fanuc s 90 20 or 90 30 PLC series NT631 and NT31 use Prodave HMI protocol in conjunction with Siemens HMI Adapter to communicate with Siemen
21. Bradley PLCs communicates to NT31 631 using the DF1 protocol This section describes setting the memory switches on the PT for use with Allen Bradley PLCs You can configure Port A or Port B on the PT for communications with Allen Bradley PLCs B To Configure NT31 631 communication for Allen Bradley 1 Start the PT 2 Press two corner keys on the PT at the same time to enter the System Menu The System Menu screen appears See Figure 3 9 Figure 3 9 System Menu SYSTEM MENU Transmit Mode Expansion Mode 3 Select Maintenance Mode The Maintenance Mode menu screen appears See Figure 3 10 Figure 3 10 Maintenance Mode Menu MAINTENANCE MODE MENU Quit PT Settings Memory Init Display History Memory Switch Alarm History LCD Settings Screen Data Disp Calendar Check Check 4 Select Memory Switch The Memory Switch screen appears See Figure 3 11 Figure 3 11 Memory Switch screen 1 4 MEMORY SWITCH AD 1 4 Key Press Sound ON OFF Printer Controller ESC P Print Method Tone Abort 5 Press the down arrow next screen or the up arrow previous screen touch switch until the fourth memory switch screen appears When you reach the fourth screen 4 4 displays in the upper left corner of the PT Port B is the default port for communication between the PT and PLC DF1 RS232 1 1 displays to the right of the Comm B Method touch switch See Figure 3 12 To use
22. E HAS BEEN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON S PRODUCT IS PROP ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM Programmable Products Omron Companies shall not be responsible for the user s programming of a programmable Product or any consequence thereof Performance Data Data presented in Omron Company websites catalogs and other materials is provided as a guide for the user in determining suitabil ity and does not constitute a warranty It may represent the result of Omron s test conditions and the user must correlate it to actual application require ments Actual performance is subject to the Omron s Warranty and Limitations of Liability Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons It is our prac tice to change part numbers when published ratings or features are changed or when significant construction changes are made However some specifica tions of the Product may be changed without any notice When in doubt spe cial part numbers may be assigned to fix or establish key specifications for your application Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate however no responsibility is assumed for clerical typographic
23. EMORY SWITCH Ally 4 4 Comm A Method None Set Comm B Select Rs 232C Comm B Method Modbus Set 6 To use port A press the Comm A Method touch switch until Modbus is shown to the right of the touch switch To use port B press the Comm B Method touch switch until it displays None See Figure 6 10 Figure 6 10 Memory Switch screen 4 4 Comm A Method MEMORY SWITCH A 4 4 Comm A Method Modbus Set Comm B Select 232 Comm Method None Set 7 Press the Set touch switch to the right of the selected Comm Method touch switch A screen displays with settings for the selected port See Figure 6 11 Figure 6 11 Memory Switch Comm Port Settings MEMORY SWITCH Comm Port A Modbus Data Bit Comm 9600 bps sea Stop Bit Slave Address Length fa Ed ES 8 Press the Comm Speed touch switch until the desired communication speed displays The setting option changes each time the touch switch is pressed Note You may only use 9600 or 19200 for communication between Modicon and NT31 631 9 Press the Quit touch switch twice The Maintenance Mode Menu screen displays The communication port and speed settings are saved 10 Press the O Check touch switch then the F check touch switch and then Comm Port A or Comm Port B to confirm communication between the PT and PLC Press the Execute button If settings are correct receive data shows If s
24. Go NT31C m Com Part J Sample Collection ow rJ System File s FileName Size System ProgramName Ver_ Modefied Nt alp0c 31c 698KB OMRON Direct Access E 211 6 18 99 11 42 36 Nt amp0e 31c 2 MITSUBISHI Direct Access E 211 6 18 99 11 42 50 AB A 31c 672KB DF1Full Duplex Protocol 1 00 12 17 98 9 34 24 31c 672KB GE Fanuc SNP X 1 1 1 00 12 22 98 12 42 26 510 31 706KB SIEMENS 7 300 400 HMI 8 12 99 12 07 18 gt B To use NT series System installer to install Allen Bradley GE Fanuc Siemens or Modicon software to the PT 1 Select the drive containing the system program from the Drive drop down list Folders on the selected drive appear 2 Select the system program s folder from the Look in drop down list File names appear in the System File s list 3 Select the PT model to be used from the PT Model drop down list Files appear in the System File s list which correspond to the PT model selected 4 Select the communication port used on your personal computer to transmit data to the PT from the Com Port drop down list Note You may only use port A on the PT when downloading the system program from the Personal Computer to the PT 5 Select the system file for your PLC vendor from the System File s list Note See Table 1 1 for file naming conventions 6 Double click on the system file name or click Go to begin installing the selected system progr
25. LCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible GE Fanuc PLCs Use with Siemens PLCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Siemens PLCs Use with Modicon PLCs This section describes specific hardware configuration requirement and equipment necessary to connect NT31 631 compatible Modicon PLCs APPENDIX A Error Messages and Troubleshooting This appendix contains common error messages provides descriptions of the problem and offers solutions APPENDIX Address Conversion Table iv This appendix contains Address Conversion Table Notice OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual The following conventions are used to indicate precautions NWARNING This message indicates information that if not observed could result in death or serious injury NCAUTION Indicates information that if not heeded could result in relatively serious or minor injury damage to the product or faulty operation Precautions This section provides general precautions for using the Omron Programmable Terminal PT and related devices Intended Audience This manual is intended for the following personnel who must also have knowledge of electrical systems an electrical
26. NT31 631 Custom Cable 25 to 9 Pin Connect PLC PT RD 3 2 SD SD 2 3 RD SG7 9SG Figure 3 18 Allen Bradley to NT31 631 Custom Cable 25 to 25 Pin Connect PLC PT RD 3 2 SD SD2 3 RD SG7 7 SG 25 Pin Male 9 Pin Male 25 Pin Male 25 Pin Male 32 3 4 3 Custom Cable for MicorLogic Figure 3 19 Allen Bradley to NT31 631 Custom Cable 8 pin Mini Din to 9 Pin Connect PLC PT 8 Pin Mini Din 9 Pin Male Figure 3 20 Allen Bradley to NT31 631 Custom Cable 8 pin Mini Din to 25 Pin Connect PLC PT 8 Pin Mini Din 25 Pin Male 33 34 SECTION 4 Use with GE Fanuc PLCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible GE Fanuc PLCs In This Section 4 1 Configuring NT31 631 for GE Fanuc 36 4 1 1 Connecting NT31 631 to GE Fanuc 90 20 or 90 30 with Built in Serial Port 36 4 1 2 Connecting NT31 631 to GE Fanuc 90 30 with CMM 37 4 2 Configuring NT31 631 for Communication with GE Fanuc PLCs 39 4 3 Allocation Area Table for GE Fanuc PLCS 41 4 4 GE Fanuc Custom Cable Requirements ss 41 4 5 GE Fanuc CMM Module Custom Cable Requirements 42 35 4 1 Configuring NT31 631 for GE Fanuc 4 1 Configuring N
27. NT31 631 Multi Vendor Connection Operation Manual Revised February 2001 OMRON Product References All OMRON products are capitalized in this manual Names of Devices and Tools PT Refers to OMRON NT series programmable terminals NTST Refers to OMRON NT series Support Tool PLC Refers to an Allen Bradley SLC 500 PLC 5 MicroLogix series GE Fanuc 90 30 series Siemens S7 300 400 series Modicon TSX Micro Premium Quantum programmable controller System installer Refers to an OMRON NT series system installer PT Type Model Applicable PLC Personal Computer NT31 NT31C Attached to the Allen Bradley SLC 500 PLC5 For IBM PC AT VO support tool 1 MicroLogix series compatibles GE Fanuc 90 30 series Siemens S7 300 400 series Modicon TSX Micro Premium Quantum series NT631 NT631C Attached to the Allen Bradley SLC 500 PLC For IBM PC AT VO support tool 1 5 MicroLogix series compatibles GE Fanuc 90 30 series Siemens S7 300 400 series Modicon TSX Micro Premium Quantum series 1 System program for NT31 NT31C and NT631 NT631C is attached to NT series Support Tool for Windows Ver 4 2 OMRON 1999 All right reserved No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical electronic photocopying recording or otherwise without the prior written permission of OMRON No patent liability is assumed with resp
28. OI intra ed 58 SIemensa cinis ene nte ens 50 Error Messages and Troubleshooting 61 GE Fanuc 90 20 or 90 30 with built in serial port 36 90 30 with CCM Module 37 Addressirig i aio ee Peri 41 Configure NTS u uy anrs EARRA ss 13 Connecting NT31 631 38 Control Notify 16 Custom Cable Requirements 41 CMM Module 42 HMI Adapter 3 46 48 50 62 64 Modicon Addressirig xxi ih cp te E ERR 58 Configure NTST T oiran 13 Connecting NT31 631 53 Control Notify 20 Custom Cable Requirements 58 TSX Micro or Premium 53 TSX Quantum esses 55 Multi Vendor Addressing See Addressing NT31 631 Configure for Allen Bradley 24 Configure for GE Fanuc 36 Configure for 53 Configure for 46 Connect to Allen Bradley MicroLogix 1000 1200 and 1500 27 Connect to Allen Bradley PLC 5 26 Connect to Allen Bradley SLC 5 02
29. ORY SWITCH Qui 1 4 AH Key Press Sound ON Printer Controller ESC P Print Method Tone Abort 5 Press the down arrow next screen or the up arrow previous screen touch switch until the fourth memory switch screen appears When you reach the fourth screen 4 4 displays in the upper left corner of the PT Port B is the default port for communication between the PT and PLC SNP X 1 1 displays to the right of the Comm B Method touch switch See Figure 4 10 To use port B skip to step 7 39 4 2 Configuring NT31 631 for Communication with GE Fanuc PLCs Figure 4 10 Memory Switch screen 4 4 Comm B Method MEMORY SWITCH Ally 4 4 Comm A Method NONE Set Comm B Select Rs 232C Comm B Method snp x 1 1 6 To use port A press the Comm A Method touch switch until SNP X 1 1 is shown to the right of the touch switch Press the Comm B Method touch switch until it displays None See Figure 4 11 Figure 4 11 Memory Switch screen 4 4 Comm A Method MEMORY SWITCH aw 4 4 Comm A Method SNP X 1 1 Comm Select RS 232C Comm B Method NONE 7 Press the Set touch switch to the right of the selected Comm Method touch switch A screen displays with settings for the selected port See Figure 4 12 Figure 4 12 Memory Switch Comm Port Settings MEMORY SWITCH Comm Port A SNP X 1 1 DataBit g pits Comm ocoo y Sua je Stop Bit 1 bit Length Parity i 8 Press
30. T31 631 for GE Fanuc This section describes specific hardware configuration requirements and equipment necessary for connecting NT31 631 to compatible GE Fanuc 90 20 or 90 30 PLCs Note Do not use 9 to 9 pin cable with 9 to 25 pin adapter when connecting the cable to 25 pin port on the PT 4 1 1 Connecting NT31 631 to GE Fanuc 90 20 or 90 30 with Built in Serial Port 36 To connect the NT31 631 to the GE Fanuc 90 30 with a built in serial port you will need the following equipment GE Fanuc 90 20 or 90 30 PLC with a built in serial port 15 to 25 pin adapter available from GE Fanuc or 15 to 9 pin adapter available from Horner Electric e NT31 631 PT with serial cable to connect PT and PLC please see Section 4 4 for appropriate cable To connect NT31 port B to GE Fanuc 90 20 or 90 30 with built in serial port 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 9 pin end of the cable to the 15 to 9 pin adapter 3 Connect the adapter to the SNP port on the GE Fanuc 90 30 with built in serial port To connect NT31 631 port A or B or NT31 port A to GE Fanuc 90 20 or 90 30 with built in serial ort 1 Connect the 9 pin cable male end to the 9 pin port of the NT31 631 port B is default 2 Connect the 9 pin cable female end to the 15 to 9 pin adapter 3 Connect the adapter to the SNP port on the GE Fanuc 90 30 with built in serial port To configure serial port for GE Fanuc 1 Configure the GE Fanuc s
31. able 0x4003 MPI communication in progress 0x4004 MPI connection down 0x0800 Toolbox is busy 0x8001 Not permitted in this mode 0x8101 Hardware error 0x8103 Access to object not permitted 0x8104 Context not supported 0x8105 Address invalid 0x8106 Data type not supported 0x8107 Data type not consistent 0x8301 Not enough memory on CPU 0x8404 Serious error 0x8500 Wrong PDU size 0xD201 Syntax error block name 0xD202 Syntax error function parameter 0xD203 Syntax error block type 0xD204 No linked data block in CPU 0xD205 Object already exists 0xD206 Object already exists 0xD207 Data block in EPROM 0xD209 Block doesn t exist OxD20E No block available 0xD210 Block number too large 0xD241 Protection level too low 0xD406 Information doesn t exist 0 0802 This job does not exist OxEF01 Wrong ID2 cyclic job handle OxFFCF API function called with an invalid parameter OxFFFF Time out check RS 232 interface 64 Siemens HMI Adapter Error Codes Code Description OxFFDE Framing error violation of the asynchronous character frame OxFFDF Parity error OxFFEO Overrun too many characters received OxFFE1 Transportation errors e g parity OxFFE2 Telegram didn t receive any acknowledge OxFFE3 Collision with a remote partner of higher priority OxFFE4 Device in receiving mode OxFFE5 Number of max connection requests exceeded OxFFE6 Function not supp
32. able 9 to 25 Pin Connect PLC PT 9 Pin Female 25 Pin Male Mo cable shield connection Tack cable shield ors PT side to connector 4 5 GE Fanuc CMM Module Custom Cable Requirements e Use25 to 9 pin cable with IC690ACC900 Adapter or CMM Module to connect to NT31 631 9 pin port e 25 to 25 pin cable with IC690ACC900 Adapter or CMM Module to connect to NT31 25 pin port Figure 4 15 GE Fanuc CMM Module to NT31 631 Custom Cable 25 to 9 Pin Connect PLC 25 Pin Male 9 Pin Male No cable shield connection Tack cable shield on PT side to Pin 1 42 Figure 4 16 GE Fanuc CMM Module to NT31 631 Custom Cable 25 to 25 Pin Connect PLC Tack cable shield to Pin 4 No cable shield connection on PT side 43 44 SECTION 5 Use with Siemens PLCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Siemens PLCs In This Section 5 1 Configuring NT31 631 for Siemens 46 5 1 1 Connecting NT31 631 to the Siemens 57 300 and 57 400 PLGSs 46 5 2 Configuring NT31 631 for Communication with Siemens PLCSs 48 5 3 Allocation Area Table for Siemens PLCS 50 5 4 Siemens Custom Cable Requirements 50 45 5 1 Configuring NT31 631 for Siemens
33. al or proofreading errors or omissions
34. am The screen indicates the progress of the download 7 Click OK on the NT series System Installer when the system program installation is complete When the download is complete the Download System Program Download Complete screen appears on the PT See Figure 1 13 Figure 1 13 Downloading the System Program Download Complete Download System Program Downloading is completed 8 Select Run System on the PT The system program re starts the PT Table 1 1 File Naming Conventions MOD Modicon 1 3 2 3 Exiting the NT series System Installer Use of the following procedures to exit the NT series System Installer Select Download System and Exit Click on the Xl button in the upper right corner of the main window e Double click on the NT series System Installer icon in the upper left section of the main window e Click on the NT series System Installer icon in the upper left section of the main window then select Close in the control menu box e Press Alt F4 10 SECTION 2 Using NTST with Allen Bradley GE Fanuc Siemens or Modicon PLCs NTST version 4 2 allows you to create screen data for NT31 631 using Allen Bradley GE Fanuc Siemens or Modicon PLCs To do so you must configure NTST to use Allen Bradley GE Fanuc Siemens or Modicon addressing This section describes how to configure NTST for use with Allen Bradley GE Fanuc Siemens or Modicon PLCs Please see Section 1 2 for compati
35. anuc Siemens or Modicon system program If you select Abort a screen display asking whether you wish to try again 1 3 2 Using the NT series System Installer The NT series System Installer uses your personal computer to download the system program for a PLC to the PT NTST V4 2 allows you to download Allen Bradley GE Fanuc Siemens Modicon system programs to NT31 631 for compatible PLCs This section outlines steps necessary to download a new system program for the NT31 631 See Section 1 2 for compatible PT and PLC combinations 1 3 2 1 Starting the NT series System Installer There are two ways to start the NT series System Installer from the Windows desktop and from NTST Figure 1 10 illustrates starting the NT series System Installer from the Windows desktop Figure 1 11 illustrates starting the NT series System Installer from NTST To start the NT series System Installer from the Windows Desktop Click on with Windows Start button Select Programs Select Omron Select Ntst4 2 Select NT series System Installer OY cca py The NT series System Installer window displays See Figure 1 11 Figure 1 10 Starting the NT series System Installer from the Windows Desktop New Office Document a Open Office Document Windows Update fy Programs gt Accessories ME StartUp x Favorites Internet Explorer Documents MS DOS Prompt GJ Windows Explorer Eh Setting
36. arges taxes and duties and will be allowed only if i the invoice is paid according to Omron s payment terms and ii Buyer has no past due amounts Interest Omron at its option may charge Buyer 1 1 2 interest per month or the maximum legal rate whichever is less on any balance not paid within the stated terms Orders Omron will accept no order less than 200 net billing Governmental Approvals Buyer shall be responsible for and shall bear all costs involved in obtaining any government approvals required for the impor tation or sale of the Products Taxes All taxes duties and other governmental charges other than general real property and income taxes including any interest or penalties thereon imposed directly or indirectly on Omron or required to be collected directly or indirectly by Omron for the manufacture production sale delivery importa tion consumption or use of the Products sold hereunder including customs duties and sales excise use turnover and license taxes shall be charged to and remitted by Buyer to Omron Financial If the financial position of Buyer at any time becomes unsatisfactory to Omron Omron reserves the right to stop shipments or require satisfactory security or payment in advance If Buyer fails to make payment or otherwise comply with these Terms or any related agreement Omron may without liabil ity and in addition to other remedies cancel any unshipped portion of Prod ucts sold hereund
37. assumes that you understand the addressing scheme used by your GE Fanuc PLC Please see your GE Fanuc user manual for assistance with addressing scheme set the Control Area for GE Fanuc 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 4 Figure 2 4 Control Notify Area tab PT Configuration F Fo GTTTTTTETIES 2 Click on the Set button in the PT Control Area group box The PLC Address screen appears See Figure 2 5 Figure 2 5 PLC Address screen for GE Fanuc PLG Address 3 Use the necessary addressing fields to specify the start address of the Control Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing the Control Area values The Control Notify Area screen reappears The information entered on the PLC address screen populates the PT Control Area group box set the Notify Area for GE Fanuc 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 4 2 Click on the Set button in the PT Notify Area group box The PLC Address screen appears See Figure 2 5 3 Use the necessary addressing fields to specify the start address of the Notify Area 17 2 2 Setting the Control Notify Area Note The start address of Notify area must be at least five words apart from start address of the Control Area 4 Click OK to accept the values
38. ble PT and PLC vendors This section assumes that you have installed NT series Support Tool Ver 4 2 with the NT Series System Installer on your personal computer To install the NTST software please see NT series Support for Windows Ver 4 1 Operation Manual V061 E1 L1 When using NT31 631 with Allen Bradley GE Fanuc or Siemens PLCs you will not have programming console support In This Section 2 1 Configuring NTST for Allen Bradley GE Fanuc Siemens or Modicon PLCS une neuste a ee ree eee 12 2 1 1 Accessing the Configuration Screen a 12 2 1 2 Choosing the PT and PLC Vendor 13 2 2 Setting the Control Notify Area 14 2 2 1 Setting the Control Notify Area for Allen Bradley ss 14 2 2 2 Setting the Control Notify Area for GE Fanuc 16 2 2 3 Setting the Control Notify Area for 18 2 2 4 Setting the Control Notify Area for Modicon a 20 11 2 1 Configuring NTST for Allen Bradley GE Fanuc Siemens or Modicon PLCs 2 1 Configuring NTST for Allen Bradley GE Fanuc Siemens or Modicon PLCs Before you create screens for the NT31 631 for use with Allen Bradley GE Fanuc Siemens or Modicon PLCs you must configure NTST to use the appropriate PLC For a list of compatibl
39. con PT Configuration x PT Type System Control Notify Area PT Control Area PLC Address Set Bomments m PT Notify Area PLC Address Comments Window Control Area 34 PLC Address Cancel 2 Click on the Set button in the PT Control Area group box The PLC Address screen appears See Figure 2 9 20 Figure 2 9 PLC Address screen for Modicon 3 4 PLC Address x Memory Type 4 Holding Register Address 1 120 Comments Cancel Help Use the necessary addressing fields to specify the start address of the Control Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing the Control Area values The Control Notify Area screen reappears The information entered on the PLC address screen populates the PT Control Area group box To set the Notify Area for Modicon 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 8 Click on the Set button in the PT Notify Area group box The PLC Address screen appears See Figure 2 9 Use the necessary addressing fields to specify the start address of the Notify Area Note The start address of the Notify area must be at least five words apart from start address of the Control Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen withou
40. e Product in the Buyers application or use of the Product At Buyer s request Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product This information by itself is not sufficient for a complete determination of the suitability of the Prod uct in combination with the end product machine system or other application or use Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application product or system Buyer shall take application responsibility in all cases but the following is a non exhaustive list of applications for which particular attention must be given i Outdoor use uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document ii Use in consumer products or any use in significant quantities iii Energy control systems combustion systems railroad systems aviation Systems medical equipment amusement machines vehicles safety equip ment and installations subject to separate industry or government regulations iv Systems machines and equipment that could present a risk to life or prop erty Please know and observe all prohibitions of use applicable to this Prod uct NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOL
41. e PT reset the PT using the Reset Button located on the back of the PT or by powering on the PT See Figure 1 5 Figure 1 5 Manually Starting the System Installer Touch switch The Select Language screen appears See Figure 1 6 Figure 1 6 Select Language Screen Select Language on 1 Select English or Japanese by touching the appropriate switch this addendum assumes you choose English here The System Installer Menu appears See Figure 1 7 Figure 1 7 Select System Installer Menu 2 Select Download System Program The Download System Program Erase System Program screen appears See Figure 1 8 Figure 1 8 Select Download System Program Erase System Program Download System Program Erase System Program Are you Sure Return to Menu Yes 3 Select Yes to erase the system program See Figure 1 8 The old system program is cleared and the Download System Program Ready screen appears See Figure 1 9 Figure 1 9 Downloading the System Program Ready 1 3 Preparing NT31 631 for Software Installation with System Installer and Downloading the System Program Download System Program Ready for downloading If Return to Menu is selected the NT31 631 returns to System Installer without clearing the system program If clearing fails a screen display asking whether you wish to try again When the system program clears successfully the NT31 631 enters standby status for downloading of the Allen Bradley GE F
42. e PT and PLC vendors please see Section 1 2 This section outlines how to access the Configuration screen and select your PT and PLC vendor 2 1 1 Accessing the Configuration Screen To configure NTST for use with Allen Bradley GE Fanuc Siemens or Modicon PLCs you use the Configuration screen There are two ways to access the PT Configuration screen when creating a new file or from an existing file To access the Configuration screen for a new file 1 Launch NTST The application opens an empty screen displays 2 The PT Configuration screen appears See Figure 2 1 Figure 2 1 PT Configuration screen PT Type System Control Notify Area PT PT Model NT31C PLC Vendor OMRON v Comments 12 To access the Configuration screen for an existing file I Launch NTST The application opens an empty screen displays Select File then Open Open an existing file The selected file opens Select Tools then PT Configuration The PT Configuration screen appears See Figure 2 1 2 1 2 Choosing the PT and PLC Vendor When the PT Configuration screen opens it defaults to the PT Type tab You use this tab to select your PT and PLC vendor To select your PT and PLC vendor 1 2 3 Select the appropriate PT model from the PT Model drop down menu Select the appropriate PLC vendor from the PLC Vendor drop down menu Enter appropriate comments in the Comments text box
43. ect to the use of the information contained herein Moreover because OMRON is constantly striving to improve its high quality products the information contained in this manual is subject to change without notice Every precaution has been taken in the preparation of this manual Nevertheless OMRON assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained in this publication Trademarks ii Microsoft Windows and Windows NT are either registered trademarks or Trademarks of Microsoft Corporation in the United States and or other countries PLC names of SLC SLC50 2 SLC50 3 SLC50 4 SLC50 5 and MicroLogix are registered trademarks of Allen Bradley Corporation PLC names of Series 90 is registered trademarks of GE Funuc Automation North America Inc Siemens and S7 are trademarks of Siemens AG Related Manuals and Their Contents The related manuals are indicated below The symbol at the end of the manual number is the revision history symbol Connections between the programmable terminal PT and programmable controller PLC etc e PC Connection Operation Manual sss V042 E1 O This Operation manual describes how to connect the programmable terminal PT to programmable controllers PLC and other equipment and how to make the setting required for these connections For information on NT series PT functio
44. ecting NT31 631 to Modicon TSX Quantum 5 56 6 2 Configuring NT31 631 for Communication with Modicon PLCs 57 6 3 Allocation Area Table for Modicon PLCS 59 6 4 Modicon Custom Cable Requirements 59 S3 6 1 Configuring NT31 631 for Modicon 6 1 Configuring NT31 631 for Modicon This section describes specific hardware configuration requirements and equipment necessary for connecting NT31 631 to compatible Modicon TSX Micro Premium or Quantum PLCs Note Do not use 9 to 9 pin cable with 9 to 25 pin adapter when connecting the cable to 25 pin port on the PT 6 1 1 Connecting NT31 631 to Modicon TSX Micro or Premium To connect the NT31 631 to the Modicon TSX Micro or Premium you will need the following equipment e Modicon TSX Micro TSX 37 21 or TSX 37 22 or Premium PLC e Multiprotocol PCMCIA card TSX SCP 111 for RS 232C or TSX SCP 114 for RS 422A e Connecting cable for PCMPIA card TSX SCP CD 1030 for RS 232C or TSX SCP CM 4030 for RS 422A communication e NT31 631 PT with serial cable to connect PT and PLC please see Section 6 4 for appropriate cable connect NT31 port B to Modicon TSX Micro or Premium PLC 1 Mount the connecting cable to PCMCIA card 2 Set the PCMCIA card to PCMCIA slot on TSX Micro or Premium PLC 3 Connect the 25 pin cable to the 25 pin end
45. engineer or the equivalent Personnel in charge of installing FA systems Personnel in charge of designing FA systems Personnel in charge of managing FA systems and facilities General Precautions WARNING vi The user must operate the product according to the performance specifications described in the operation manuals Before using the product under conditions which are not described in the manual or applying the product to nuclear control systems railroad systems aviation systems vehicles combustion systems medical equipment amusement machines safety equipment and other systems machines and equipment that may have a serious influence on lives and property if used improperly consult your OMRON representative Make sure that the ratings and performance characteristics of the product are sufficient for the systems machines and equipment and be sure to provide the systems machines and equipment with double safety mechanisms This manual provides information for using the Programmable Terminal Be sure to read this manual before attempting to use the software and keep this manual close at hand for reference during operation Do not use input functions such as PT touch switches for applications where danger to human life or serious damage is possible or for emergency switch applications Table of Contents Revised Febr ary 2001 OE E i OMRON Product References U ii Related Manual
46. er and stop any Products in transit until Buyer pays all amounts including amounts payable hereunder whether or not then due which are owing to it by Buyer Buyer shall in any event remain liable for all unpaid accounts Cancellation Etc Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses Force Majeure Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control including earthquakes fires floods strikes or other labor disputes shortage of labor or materials accidents to machinery acts of sabotage riots delay in or lack of transportation or the requirements of any government authority Shipping Delivery Unless otherwise expressly agreed in writing by Omron a Shipments shall be by a carrier selected by Omron Omron will not drop ship except in break down situations b Such carrier shall act as the agent of Buyer and delivery to such carrier shall constitute delivery to Buyer c All sales and shipments of Products shall be FOB shipping point unless oth erwise stated in writing by Omron at which point title and risk of loss shall pass from Omron to Buyer provided that Omron shall retain a security inter est in the Products until the full purchase price is paid d Delivery and shipping dates are estimates only and e Omron will package Products as it deems proper for protection again
47. erial port for SNP X mode 2 Set the baud rate for 9600 or 19 200 Figure 4 1 Connecting NT31 to GE Fanuc with Built in Serial Port GE Fanuc NT 31 PT 90 20 or 90 30 with built in serial port 25 to 9 pin with adapter Or 9 to 9 pin with adapter Figure 4 2 Connecting NT631 to GE Fanuc with Built in Serial Port GE Fanuc 90 20 or 90 30 with built in serial port NT 631 9 to 9 pin with OR adapter 4 1 2 Connecting NT31 631 to GE Fanuc 90 30 with CMM Module To connect the NT31 to the GE Fanuc 90 30 with a CMM module you will need the following equipment e GE Fanuc 90 30 PLC with CMM module e NT31 631 PT with serial cable to connect PT and PLC please see Section 4 4 for appropriate cable To connect NT31 port B to GE Fanuc 90 30 with CMM module 1 Connect the 25 pin cable to port B of the NT31 2 Connect the 25 pin end of the cable to the RS232 port on the CMM module To connect NT631 port A or B or NT31 port A to GE Fanuc 90 30 with CMM module 1 Connect the 9 pin cable to the 9 pin port of the NT31 631 port B is default 2 Connect the 25 pin end of the cable to the RS232 port on the CMM module configure serial port for CCM Module 1 Configure the CMM Module for SNP mode 2 Setthe baud rate for 9600 or 19 Figure 4 5
48. essing the Configuration Screen l eene enne 12 2 1 2 Choosing the PT and PLC Vender u I 13 2 2 Setting the Control Notify 14 2 2 1 Setting the Control Notify Area for Allen Bradley see 14 2 2 2 Setting the Control Notify Area for GE Fanuc U eem nen 16 2 2 3 Setting the Control Notify Area for Siemens U eee 18 2 2 4 Setting the Control Notify Area for Modicon meme 20 Use with Allen Bradley PLCGs 23 3 1 Configuring NT31 631 for Allen Bradley r 24 3 1 1 Connecting NT31 631 to Allen Bradley SLC 5 02 sse 24 3 1 2 Connecting NT31 631 to Allen Bradley SLC 5 03 5 04 and 5 05 25 3 1 3 Connecting NT31 631 to Allen Bradley PLC5 sse enne 26 3 1 4 Connecting NT31 631 to Allen Bradley MicroLogix 1000 1200 and 1500 27 3 2 Configuring NT31 631 for Communication with Allen Bradley PLCS 29 3 3 Allocation Area Table for Allen Bradley PLCs r 31 3 4 Allen Bradley Custom Cable Requirements sesssssssssssseeeeeeneeennnee 31 3 4 1 Custo
49. ettings are incorrect you will receive an error message S8 6 3 Allocation Area Table for Modicon PLCs Note Modicon PLC Addressing Addressing Memory Type Identifier Range Limits Output holding bits 0 1 to 9999 Input bits 1 1 to 9999 Input registers 3 1 to 9999 Output holding register 4 1 to 9999 Extended memory 6 1 to 9999 Internal bit M 0 to 9998 Internal word MW 0 to 9998 Full addressing range is covered depending on the PLC The order of bit numbers that can be specified with NTST and those used at PLC side may differ depending on a PLC When setting a bit number with NTST set a number from 0 to 15 The least significant bit is 0 and the most significant bit is 15 For example when the bit 15 is ON and the other bits are OFF the value in WORD will be 8000 hex Available memory types in Modicon TSX Micro and Premium are M and MW 1 To use M select 0 Coil or 1 inputas memory type 2 use MW select 4 Holding Register as memory type 3 Add 1 to actual address number in Modicon PLCs for input address number in Please refer to the following examples Actual Address Set Address in NTST 8 00009 MW30 40031 MW40 bit3 40041 3 6 4 Modicon Custom Cable Requirements Figure 6 12 Modicon to NT31 631 Custom Cable 25 to 9 Pin Connect PLC TSX SCP CD 1030 PT 25 Pin Female 9 Pin Male 59 6 4 Modicon Custom Cable Requi
50. ity is asserted Indemnities Buyer shall indemnify and hold harmless Omron Companies and their employees from and against all liabilities losses claims costs and expenses including attorney s fees and expenses related to any claim inves tigation litigation or proceeding whether or not Omron is a party which arises or is alleged to arise from Buyer s acts or omissions under these Terms or in any way with respect to the Products Without limiting the foregoing Buyer at its own expense shall indemnify and hold harmless Omron and defend or set tle any action brought against such Companies to the extent based on a claim that any Product made to Buyer specifications infringed intellectual property rights of another party Property Confidentiality Any intellectual property in the Products is the exclu sive property of Omron Companies and Buyer shall not attempt to duplicate it in any way without the written permission of Omron Notwithstanding any charges to Buyer for engineering or tooling all engineering and tooling shall remain the exclusive property of Omron All information and materials supplied by Omron to Buyer relating to the Products are confidential and proprietary and Buyer shall limit distribution thereof to its trusted employees and strictly prevent disclosure to any third party Export Controls Buyer shall comply with all applicable laws regulations and licenses regarding i export of products or information iii sa
51. le of products to forbidden or other proscribed persons and ii disclosure to non citizens of regulated technology or information Miscellaneous a Waiver No failure or delay by Omron in exercising any right and no course of dealing between Buyer and Omron shall operate as a waiver of rights by Omron b Assignment Buyer may not assign its rights hereunder without Omron s written consent c Law These Terms are governed by the law of the jurisdiction of the home office of the Omron company from which Buyer is purchasing the Products without regard to conflict of law princi ples d Amendment These Terms constitute the entire agreement between Buyer and Omron relating to the Products and no provision may be changed or waived unless in writing signed by the parties e Severability If any provi sion hereof is rendered ineffective or invalid such provision shall not invalidate any other provision f Setoff Buyer shall have no right to set off any amounts against the amount owing in respect of this invoice g Definitions As used herein including means including without limitation and Omron Compa nies or similar words mean Omron Corporation and any direct or indirect subsidiary or affiliate thereof Certain Precautions on Specifications and Use 1 Suitability of Use Omron Companies shall not be responsible for conformity with any standards codes or regulations which apply to the combination of th
52. m Cable Cable for SLC 5 orisirisii iniae daera EAEE AEAEE ER inea ERATARA neret nere nennen 31 3 4 2 Custom Cable for PLC Sei a a a a Taai aE sa ads 32 3 4 3 Custom Cable for MicorLogiG uu aasisassssa EEN EAA Eea nnne 33 Use with GE Fanuc PLG8s uuu 35 4 1 Configuring NT31 631 for GE Fanuc 36 4 1 1 Connecting NT31 631 to GE Fanuc 90 20 or 90 30 with Built in Serial Port 36 4 1 2 Connecting NT31 631 to GE Fanuc 90 30 with CMM 37 4 2 Configuring NT31 631 for Communication with GE Fanuc 5 39 4 3 Allocation Area Table for GE Fanuc PLCGSs 41 4 4 GE Fanuc Custom Cable Requirements 41 Vii 4 5 GE Fanuc CMM Module Custom Cable Requirements a 42 Use with Siemens PLGCGs U uu 45 5 1 Configuring NT31 631 for Siemens r 46 5 1 1 Connecting NT31 631 to the Siemens 57 300 57 400 PLCGSs 46 5 2 Configuring NT31 631 for Communication with Siemens 48 5 3 Allocation Area Table for Siemens PLCS
53. m start address of the Notify Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing Window Control Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the Window Control Area group box Click OK on the Control Notify Area screen A new application window opens and you are ready to create your screen data 19 2 2 Setting the Control Notify Area 2 2 4 Setting the Control Notify Area for Modicon This section lists the steps necessary to set the Control Notify W indow Area in NTST for Modicon PLCs This section assumes that you understand the addressing scheme used by your Modicon PLC Please see your User s Manual of Modicon for assistance with addressing scheme Note The notation of address follows the way of TSX Quantum When you use TSX Micro or Premium please convert by the following rule e To use M select 0 Coil or I Input as memory type e To use MW select 4 Holding Register as memory type e Add 1 to actual address number in Modicon PLCs for input address number in NTST Please refer to the following examples Actual Address Set Address in NTST 8 00009 MW30 40031 MW40 bit3 40041 3 set the Control Area for Modicon 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 8 Figure 2 8 PLC Address screen for Modi
54. munication between the PT and PLC Press the Execute button If settings are correct receive data shows If settings are incorrect you will receive an error message 30 3 3 Allocation Area Table for Allen Bradley PLCs Allen Bradley SLC 500 Memory Identifier File Number Element Sub Bit Type Range Number Element Range Range Number Range Bit B 3 9 255 0 255 0 15 Counter 5 9 255 0 255 0 2 0 15 Integer N 7 9 255 N 0 255 0 15 Control R 6 9 255 R 0 255 0 2 0 15 Status S 2 S 0 255 0 15 Time T 4 9 255 T 0 255 0 2 0 15 Input Output Settings Memory Identifier Slot Number Word Number Terminal Number Type Input 1 30 0 255 0 15 Output 1 30 0 255 0 15 Note for PLCS users e Rack Number should be entered in place of Slot Number entry e Group Number should be entered in place of Word Number entry e Bit Number should be entered in place of Terminal Number in decimal Valid value are 0 through 15 3 4 Allen Bradley Custom Cable Requirements 3 4 1 Custom Cable Cable for SLC5 Figure 3 15 Allen Bradley to NT31 631 Custom Cable 9 to 9 Pin Connect 9 Pin Female PLC RD 2 SD3 SG s PT 9 Pin Male 3 4 Allen Bradley Custom Cable Requirements Figure 3 16 Allen Bradley to NT31 631 Custom Cable 9 to 25 Pin Connect PLC Pt 9 Pin Female 25 Pin Male 3 4 2 Custom Cable for PLC5 Figure 3 17 Allen Bradley to
55. nected to the PT Enter the System Menu Maintenance Mode and press Memory Switch Move to the Memory Switch 4 4 screen Press the MPI button Change the PLC MPI Address PLC rack number and CPU slot number to match the PLC settings Error Code 0x0101 HMI Adapter is no longer responding Cycle power on HMI adapter by disconnecting from PLC or cycling power on PLC 63 Siemens PLC Error Codes Siemens PLC Error Codes Code Description 0x0015 Negative acknowledge or invalid incomplete response 0x0101 Communication link not available 0x010A Negative acknowledge time out error 0x010C Data does not exist or is locked 0x0200 Unknown error 0x0201 Wrong interface specified 0x0202 Too many interfaces 0x0203 Toolbox already initialized 0x0204 Toolbox already initialized with another connection 0x0205 Toolbox not initialized 0x0206 Can t set handle 0x0207 Data segment isn t locked 0x0209 Data field incorrect 0x0302 Block size is too small 0x0303 Block boundary exceeded 0x0313 Wrong MPI baud rate selected 0x0314 Highest MPI address is wrong 0x0315 MPI address already exists 0x031A Not connected to MPI network 0x031B Short circuit at MPI bus 0x0320 Hardware error 0x0381 Hardware error 0x4001 Communication link unknown 0x4002 Communication link not avail
56. ns operations and restrictions e NT31 31C Programmable Terminal Setup V062 E1 O e NT631 631C Programmable Terminal Setup Manual V063 E1 O e NT31 31C NT631 631C Programmable Terminal Reference Manual V064 E1 O These manuals contain full descriptions of NT series PT functions operations and restrictions e Support Tool for Windows Ver 4 1 Operation Manual V061 E1 O The screens displayed in the PT are created and transferred with the Support Tool This manual describes how to create and transfer the screen data It describes also how to use the system installer for installing the system program to the PT iii How to Use the Manual SECTION 1 SECTION 2 SECTION 3 SECTION 4 SECTION 5 SECTION 6 This Operation Manual comprises the following Sections Connectable Hardware Combinations This section provides an overview of system requirements necessary to use NT31 631 with Allen Bradley GE Fanuc Siemens or Modicon PLCs Using NTST with Allen Bradley GE Fanuc or Siemens PLCs This section describes how to configure NTST for use with Allen Bradley GE Fanuc Siemens or Modicon PLCs Use with Allen Bradley PLCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Allen Bradley PLCs Use with GE Fanuc P
57. odicon shiA hi Fx Link 1 DM D D N R 4 Holding 0 32767 0 9999 0 9999 7 10 255 1 9999 Register 0 255 1 9999 2 CH M M B M CH M 0 32767 0 9999 0 9999 3 10 255 1 9999 0 9999 0 255 0 255 3 TIM T T T a T 0 32767 0 9999 0 9999 4 10 255 0 127 0 255 4 CNT C C G 0 32767 0 9999 0 9999 5 10 255 0 63 0 255 5 HR L T 0 32767 0 9999 1 1 9999 0 30 6 AR S 0 32767 0 9999 0 0 30 7 LR B 16 A S G 0 32767 0 270 2 1 9999 0 255 8 W W 1 6 0 32767 0 270F 9 X 16 X 8 s I PIW 1 Input 0 270F 0 23417 1 9999 0 127 1 9999 10 Y 16 Y 8 Q i Q PQW 0 Coil 0 270F 0 23417 1 9999 0 127 1 9999 1 1 EM R R S 0 32767 0 9999 6 10 255 1 9999 0 255 12 T SA 4 10 255 1 9999 0 255 13 C SB 5 10 255 1 9999 0 255 Omron Mitsubi Mitsubis AB GE Memory Siemens Modicon shiA hi Fx Link 14 R SC 6 10 255 1 9999 0 255 15 i u Al i 3 Input 1 9999 Register 1 9999 16 AQ 1 9999 17 TK 0 32767 18 EMO D i DB0 6 Extend 0 32767 0 65533 Memory File 1 1 9999 19 EM1 2 T u u DB1 6 Extend 0 32767 0 65533 Memory File 2 1 9999 20 EM2 EB
58. orted in the current mode OxFFE7 Mode not supported OxFFE8 Port handle not valid OxFFE9 Hardware does not support this function OxFFEA Port table full OxFFEB Timeout during write operation OxFFEC Value out of range OxFFED Port not open OxFFEE Can t allocate buffer OxFFEF Device not installed OxFFFO Device already open OxFFFD OxFFFE Unknown function Unknown error 65 66 APPENDIX B Address Conversion Table This appendix contains Address Conversion table In This Section Address Conversion Table 67 Address Conversion Table Address Conversion Table 68 Address conversion will be available when converting between 2 different vendor types In order to simplify the conversion rules the common code table method will be used In this table each address type of a particular vendor is assigned a code During conversion of vendor the address type of the source vendor will be converted to the address type having the same code in the target vendor If there is no code available for an address type in the target vendor the address will be reset to NULL i e no address If the target vendor type does not have the address range which source vendor supports all of the addresses which exceed the target range will be reset to NULL Omron Mitsubi Mitsubis AB GE Memory Siemens M
59. radley GE Fanuc Siemens and Modicon software installation using the NT31 631 System Installer It also outlines how to use the NT series System Installer to download Allen Bradley GE Fanuc Siemens and Modicon system programs from your personal computer to the PT The section assumes that you have installed NT Series Support Tool Ver 4 2 with the NT Series System Installer on your personal computer to default paths To install the NTST software please refer to the NT series Support Tool for Windows Ver 4 1 Operation Manual V061 E1 L When using NT31 631 with Allen Bradley GE Fanuc Siemens or Modicon PLCs you will not have programming console support 1 3 1 Preparing NT31 631 for Software Installation with System Installer If the NT31 631 has no system program installed or if the system program is destroyed System Installer is activated when the PT is powered ON To use NT31 631 with Allen Bradley GE Fanuc Siemens or Modicon PLCs you must manually start System Installer and clear Omron s system program from the PT You can then download the system program for Allen Bradley GE Fanuc Siemens or Modicon PLCs When downloading the system program to the PT you must use port A on the PT This section outlines the steps necessary to run System Installer and clear the existing program To prepare NT31 631 for system installation with System Installer While holding down the touch switch in the top left corner of th
60. re NTS T oratsi anae 13 Connecting NT31 631 26 Control Notify Area 14 Custom Cable Requirements 31 MicroLogix 1000 1200 and 1500 27 PLC5 imet ene 26 SLC 5 02 ri tdt deuten 24 SLC 5 03 5 04 and 5 05 25 Allocation Area Table See Addressing Bit Addressing See Addressing Cable Requirements See Custom Cable Requirements Cables for PC P T uu e tace 4 CMM Module GE PanuG chee teen in Der eio eni rere 42 Communication Configure Communication between NT31 631 and Allen Bradley PLCs 29 Configure Communication between NT31 631 and GE Fanuc PLGOGSs 39 Configure Communication between NT31 631 and Modicon 56 Configure Communication between NT31 631 and Siemens PLCS 48 Compatible gHe 3 PT MOdelS i etd ct 3 Control Notify Area Allen Bradley eee 14 GE Fan G6 nu nei eise REP AS 16 MOdICOM eee 20 SIG ens uidet E edge M NE Anna 18 Custom Cable Requirements Allen Bradley eene 31 CMM Module GE Fansite eed 42 Sieniens z dede nb een 50 GE Fac 41 MOGIC
61. rements Figure 6 13 Modicon to NT31 631 Custom Cable 25 to 25 Pin Connect PLC TSX SCP CD 1030 PT 25 Pin Female 25 pin Male Figure 6 14 Modicon to NT31 Wiring RS 422A PLC TSX SCP CX 4030 Orange White White Orange White Green Green White Brown White 25 pin Male Figure 6 15 Modicon to NT631 Wiring RS 422A PLC TSX SCP CX 4030 Orange White SDB White Orange SDA White Green O RDB o Green White RDA Brown White Terminal 60 APPENDIX A Error Messages and Troubleshooting This appendix contains common error messages provides descriptions of the problem and offers solutions In This Section Error Messages and Troubleshooting 62 Siemens Error Messages and Troubleshooting 63 Siemens PEG Error GOG6S iiri orte aene sepe Foe Deko Ux nais renra s ponugs 64 Siemens HMI Adapter Error Codes 65 61 Error Messages and Troubleshooting Error Messages and Troubleshooting Error Message on PT Description Solution No Screen Data No Screen Data is saved in Screen Memory Download Screen Data using the Support Tool Then set the PT to Transmit Mode and download Screen Data again Screen Data has not been saved in Screen Memory Se
62. rs as a suffix to the catalog number on the front cover of the manual Cat No V060 E1 2 Revision The following table outlines the changes made to the manual during each revision Page numbers refer to the previous version Revision code Date Revised content 1 November 1999 Original production 2 January 2001 Descriptions for the following products added Modicon PLCs Allen Bradley PLC5 Allen Bradley MicroLogix 1000 1200 and 1500 73 74 Terms and Conditions of Sale omnon Offer Acceptance These terms and conditions these Terms are deemed part of all quotes agreements purchase orders acknowledgments price lists catalogs manuals brochures and other documents whether electronic or in writing relating to the sale of products or services collectively the Products by Omron Electronics LLC and its subsidiary companies Omron Omron objects to any terms or conditions proposed in Buyers purchase order or other documents which are inconsistent with or in addition to these Terms Prices Payment Terms All prices stated are current subject to change with out notice by Omron Omron reserves the right to increase or decrease prices on any unshipped portions of outstanding orders Payments for Products are due net 30 days unless otherwise stated in the invoice Discounts Cash discounts if any will apply only on the net amount of invoices sent to Buyer after deducting transportation ch
63. s Figure 5 1 Connecting NT31 to Siemens HMI Adapter with MPI port Siemens NT 31 PT 7 300 S7 400 MPI port 25 to 9 pin or PI 9 to 9 pin Siemens HMI Adapter 46 Figure 5 2 Connecting NT631 to Siemens with MPI port Siemens 7300 S7400 MPI port NT 631 9 to 9 pin Siemens HMI Adapter 47 5 2 Configuring NT31 631 for Communication with Siemens PLCs 5 2 Configuring NT31 631 for Communication with Siemens PLCs Siemens PLCs communicate to NT31 631 using the Prodave HMI protocol in conjunction with the Siemens HMI adapter This section describes setting the memory switches on the PT for use with Siemens PLCs You can configure Port A or Port B on the PT for communications with Siemens PLCs To Configure NT31 631 communication for Siemens 1 Start the PT 2 Press two corner keys on the PT at the same time to enter the System Menu The System Menu screen appears See Figure 5 3 Figure 5 3 System Menu SYSTEM MENU Transmit Mode Expansion Mode 3 Select Maintenance Mode The Maintenance Mode menu screen appears See Figure 5 4 Figure 5 4 Maintenance Mode Menu MAINTENANCE MODE MENU Quit PT Settings Memory Init Display History Memory Switch Alarm History LCD Settings Screen Data Disp Calendar Check IO Check
64. s gt Omon d MC NT series Support Tool IS 4 T Uninstall NTST Run z E S tor ET Shut Down To start the NT series System Installer from within NTST Click on with Windows Start button Select Programs Select Omron Select Ntst4 2 Select NT series Support Tool Click on Connect pu o9 5 ROO c Select Launch System Installer See Figure 1 10 Figure 1 11 Starting the NT series System Installer from within NTST File View Connect Help Comms Setting Upload PT gt NT series Support Tool gt Launch System Installer The NT series System Installer window displays See Figure 1 11 1 3 2 2 Installing the System Program 1 3 Preparing NT31 631 for Software Installation with System Installer and Downloading the System Program This section describes how to install the System Program for Allen Bradley GE Fanuc Siemens or Modicon PLCs using the NT Series System Installer Use system installer to select your PT model You must know which communication port you are using on your personal computer to transmit the data to the PT In addition you need to know which drive and folder contain the appropriate system program If the files are located on a network drive you must map the drive before you can use it Figure 1 12 NT series System Installer window 4 NT Series System Installer d x Download System Help Drive Look in c MIKE C c PT Model NI Files
65. s S7 300 and S7 400 PLCs NT631 and NT31 use Modbus protocol to communicate with Modicon TSX Micro Premium and Quantum PLCs These operator interfaces use familiar addressing schemes to quickly program the NT631 and NT31 using Allen Bradley GE Fanuc Siemens Modicon s PLC address formats Figure 1 1 Using NT31 631 with Allen Bradley Allen Bradley SLC 500 PLC 5 MicroLogix series PLCs NT 631 or Figure 1 2 Using NT31 631 with GE Fanuc GE Fanuc 90 20 or 90 30 series PLCs NT31 631 OR Figure 1 3 Using NT31 631 with Siemens Siemens S7 300 or S7 400 series PLCs NT 631 Siemens HMI OR Adapter Figure 1 4 Using NT31 631 with Modicon Modicon TSX Micro Premium Quantum PLCs NT 631 OR 1 2 System Requirements PT Models PLC Vendors The following lists the numbers of compatible devices necessary to use NT31 631 PTs with Allen Bradley SLC 500 GE Fanuc Series 90 20 and 90 30 PLCs and Siemens S7 300 and S7 400 PLCs and Modicon TSX Micro Premium and Quantum PLCs NT31C ST141 B E NT31C ST141 B EV1 NT31C ST141 B EV2 NT31 ST121 B E NT31 ST121 B EV1 NT31 ST121 B EV2 NT631C ST151 B NT631C ST141 B NT631 ST211 B E NT631 ST211 B EV1 NT631 ST211 B EV2 E NT631C ST151 B EV1 NT631C ST151 B EV2 E NT631C ST141 B EV1 NT631C ST141 B EV2 Allen Bradley SLC 500 PLCs SLC 5 02
66. s and Their Contents U u u ili How to Use the Manual ccc ccssccsssteiecscccsssessavescctscencscessiveccsceensecsasinsessscvesscdeaavnsccssxenccctsousaerseossss iv hug M E E eR vi Intended Audience oie Len cag eee eo EE deeded e irren ia eda a adde ae qu dU Ad aa eau aed vi General Precautions uu u een LR ua nea ei vi Table Of Con t ent uu ce tav Fee eee te ena tee ea re ora Ev SE eaten vii Connectable Hardware Combinations eere 1 1 1 SYSTEM u y leet re eeu eat 2 1 2 System Requirements ttp ERU 3 1 3 Preparing NT31 631 for Software Installation with System Installer and Downloading the System Program eere erret re ere petet trem teg eere pego 4 1 3 1 Preparing NT31 631 for Software Installation with System 4 1 3 2 Using the NT series System Installer l enne 6 1 3 2 1 Starting the NT series System Installer a 6 1 3 2 2 Installing the System Program u u 7 1 3 2 3 Exiting the NT series System Installer 9 Using NTST with Allen Bradley GE Fanuc Siemens or Modicon PLCs 11 2 1 Configuring NTST for Allen Bradley GE Fanuc Siemens or Modicon 12 2 1 1 Acc
67. s number to clear the screen First word of the Control Area in the PLC is not programmed with the appropriate initial screen number Reprogram first word of Control Area with the appropriate initial screen number using hand held programmer or PC based software Siemens Error Messages and Troubleshooting Error Message on PT Description Solution Duplicate MPI Addr PT MPI Address and PLC MPI Address are set to the same value Change either the PT MPI Address or the PLC MPI Address so that they are not set to the same value Invalid Max MPI Addr The Max MPI Address is not larger than the PT MPI Address and or the PLC MPI Address Press the Max MPI Addr button to change the Max MPI Address to a value that is greater than both the PT MPI Address and the PLC MPI Address Error Code 0x0315 The PT MPI Address is already used by some other MPI node in the MPI network Enter the System Menu Maintenance Mode and press Memory Switch Move to the Memory Switch 4 4 screen Press the MPI button Change the PT MPI Address to a value that is not used anywhere else on the MPI network Error Code 0x4002 or Error Code 0x4004 or Error Code 0x8105 PLC MPI Address PLC rack number or CPU slot number is set to an incorrect value Use the PLC programming software to determine the PLC MPI Address PLC rack number and CPU slot number that is con
68. screen See Figure 5 8 The settings for PLC Rack Number CPU Slot Number and PLC MPI Address must match the settings of the PLC The PT MPI Address must be different than the PLC MPI Address Figure 5 8 MPI Address screen PT MPI Address NET gaa PLC MPI Address 0 0 2 Abort 8 Press the Comm Speed touch switch until the desired communication speed displays The setting option changes each time the touch switch 1s pressed Note You may only use 9600 or 19200 for communication between Siemens and NT31 631 9 Press the Quit touch switch twice The Maintenance Mode Menu screen displays The communication port and speed settings are saved 10 Press the O Check touch switch then the F check touch switch and then Comm Port A or Comm Port B to confirm communication between the PT and PLC Press the Execute button If settings are correct receive data shows If settings are incorrect you will receive an error message 49 5 3 Allocation Area Table for Siemens PLCs 5 3 Allocation Area Table for Siemens PLCs Siemens PLC Bit Bit Word Word Block Memory Type Addressing Addressing Addressing Addressing Number Identifier Range Limits Identifier Rang Limits Input 0 0 to 511 7 IW 0 to 510 Output Q 0 0 to 511 7 QW 0 to 510 Bit Memory M 0 0 to 2047 7 MW 0 to 2046 T 0 to 511 Counter 0 to 511 Data Block DBX 0 0 to 65533 7 DBW 0
69. specify the start address of the Control Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing the Control Area values The Control Notify Area screen reappears The information entered on the PLC address screen populates the PT Control Area group box set the Notify Area for Siemens 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 6 Click on the Set button in the PT Notify Area group box The PLC Address screen appears See Figure 2 7 Use the necessary addressing fields to specify the start address of the Notify Area Note The start address of the Notify area must be at least five words apart from start address of the Control Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing Notify Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the PT Notify Area group box set the Window Control Area for Siemens 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 6 Click on the Set button in the Window Control Area group box The PLC Address screen appears See Figure 2 7 Use the necessary addressing fields to specify the start address of the Window Control Area Note The start address of Window Control area must be at least nine words apart fro
70. st nor mal handling and extra charges apply to special conditions Claims Any claim by Buyer against Omron for shortage or damage to the Products occurring before delivery to the carrier must be presented in writing to Omron within 30 days of receipt of shipment and include the original trans portation bill signed by the carrier noting that the carrier received the Products from Omron in the condition claimed Warranties a Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron or such other period expressed in writing by Omron Omron disclaims all other warranties express or implied b Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED ABOUT NON INFRINGEMENT MERCHANTABIL 15 16 ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or oth erwise of any intellectual property right c Buyer Remedy Omron s sole obli gation hereunder shall be at Omron s election to i replace in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof the non complying Product
71. t DB2 6 Extend 0 32767 0 65533 Memory File 3 1 9999 21 EM3 d T u t DB3 6 0 32767 0 65533 Extended Memory File 4 1 9999 22 EM4 E j i DB4 6 0 32767 0 65533 Extended Memory File 5 1 9999 23 EM5 3 d DB5 6 0 32767 0 65533 Extended Memory File 6 1 9999 24 EM6 i i u DB6 0 6 0 32767 65533 Extended Memory File 7 1 9999 25 EM7 7 6 0 32767 0 65533 Extended Memory File 8 1 9999 26 EM8 DB8 6 0 32767 0 65533 Extended Memory File 9 1 9999 69 Address Conversion Table 70 Omron Mitsubi Mitsubis AB GE Memory Siemens Modicon shiA hi Fx Link 27 EM9 DB9 6 0 32767 0 65533 Extended Memory File 10 1 9999 28 EMA DB10 0 32767 0 65533 29 EMB DB11 0 32767 0 65533 30 EMC DB12 0 32767 0 65533 31 TU i 0 32767 32 CU 5 k 0 32767 PRE value ACC value 3Current Bank n is from 1 4095 There is no conversion for Data Block 16 hexadecimal 8 octal Shade Word or byte address Non shade Bit address Addressing Allen Bradley a 31 GE Fanuc cere eaten 41 MOGICON ses iine eme eit nearest 58 SIGMONS eiie c HU RT pes 50 Allen Bradley Addressirig iioii anas 31 Configu
72. t changing Notify Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the PT Notify Area group box To set the Window Control Area for Modicon 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 8 Click on the Set button in the Window Control Area group box The PLC Address screen appears See Figure 2 9 Use the necessary addressing fields to specify the start address of the Window Control Area Note The start address of Window Control area must be at least nine words apart from start address of the Notify Area Click OK to accept the values you set Click Cancel to return to the Control Notify screen without changing Window Control Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the Window Control Area group box Click OK on the Control Notify Area screen A new application window opens and you are ready to create your screen data 21 22 SECTION 3 Use with Allen Bradley PLCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Allen Bradley PLCs In This Section 3 1 Configuring NT31 631 for Allen Bradley 24 3 1 1 Connecting NT31 631 to Allen Bradley SLC 5 02 24 3 1 2
73. t the PT to Transmit Mode and download Screen Data by using NTST No Direct Connection Info No Direct Connection Information is set in Screen Data Set Direct Connection Information in Screen Data by using the Support Tool Then set PT to Transmit Mode and download Screen Data again There is no Control Notify area info programmed in Screen Data Program Control Notify area information in Screen Data using NTST Set the PT to Transmit Mode and download Screen Data again Set the Control Notify Area with appropriate settings See Section 2 2 Incorrect Screen Data Screen Data in Screen Memory does not match with the System Program Initialize Screen Memory and download Screen Data again The Screen Data in Screen Memory does not match the driver protocol in the PT Clear the Screen Memory in the PT using the Memory Initialization button in Maintenance Mode Menu and download Screen Data again No Starting Screen Specified Starting Screen is not saved Fix Screen Data using the support tool Then set the PT to Transmit Mode and download Screen Data again The Starting Screen is not defined or is invalid Specify initial screen in the PT configuration menu of NTST under the System Tab After specifying download Screen Data to PT again None PT Screen is blank but communicating with PLC Value at first word in Control Area possibly set to 0 The PT uses thi
74. the Comm Speed touch switch until the desired communication speed displays The setting option changes each time the touch switch is pressed Note You may only use 9600 or 19200 for communication between GE Fanuc and NT31 631 9 Press the Quit touch switch twice The Maintenance Mode Menu screen displays The communication port and speed settings are saved 10 Press the I O Check touch switch then the F check touch switch and then Comm Port A or Comm Port B to confirm communication between the PT and PLC Press the Execute button If settings are correct receive data shows If settings are incorrect you will receive an error message 40 4 3 Allocation Area Table for GE Fanuc PLCs GE Fanuc PLC Addressing Memory Type Identifier Word Reference Register R Analogue Input AI Analogue Output AQ Bit Discrete Input l Discrete Output Q Discrete Temporary T Discrete Internal M System Status S System Status A SA System Status B SB System Status C SC Genius Global Data G Note Full addressing range is covered depending on the PLC 4 4 GE Fanuc Custom Cable Requirements Figure 4 13 GE Fanuc to NT31 631 Custom Cable 9 to 9 Pin Connect PLC PT 9 Pin Female 9 Pin Male Mo cable shield connection Tack cable shield on PT aida to connector 41 4 5 GE Fanuc CMM Module Custom Cable Requirements Figure 4 14 GE Fanuc to NT31 631 Custom C
75. to 65532 1 to 4095 1 to 4095 TBR 5 4 Siemens Custom Cable Requirements To communicate between PLC and PT available from Omron unless stated PLC PT Model Connector Length Omron Part Vendor pin pin Number NT631 port A B 9 9 N A See cable diagram Siemens or NT31 port A Figure 5 9 NT31 port B 25 9 N A See cable diagram Figure 5 10 Protocol the interface between NT31 631 and a Siemens PLC is provided by Prodave HMI protocol This protocol requires use of a Siemens HMI Adapter provided for by Siemens Siemens Part 6ES7 972 OCA10 OXAO Figure 5 9 Siemens HMI Adapter to Omron PT 9 Pin to 9 Pin Cable Siemens HMI Adapter No cable shield connection on PT Sk 9 Pin Male DB connector Solder cable shield to connector case Figure 5 10 Siemens HMI Adapter to Omron PT 9 Pin to 25 Pin Cable 50 Siemens HMI Adapter No cable shield connection on PT 25 Pin Male 9 Pin Female DB connector DB connector Solder cable shidd to connector case 51 52 SECTION 6 Use with Modicon PLCs This section describes specific hardware configuration requirements and equipment necessary to connect NT31 631 to compatible Modicon PLCs In This Section 6 1 Configuring NT31 631 for Modicon 54 6 1 1 Connecting NT31 631 to Modicon TSX Micro or Premium PLGSs 54 6 1 2 Conn
76. you set Click Cancel to return to the Control Notify screen without changing Notify Area values The Control Notify Area screen reappears The information entered on the PLC Address screen populates the PT Notify Area group box 5 Click OK on the Control Notify Area screen A new application window opens and you are ready to create your screen data 2 2 3 Setting the Control Notify Area for Siemens This section lists the steps necessary to set the Control Notify W indow Control Area in NTST for Siemens PLCs This section assumes that you understand the addressing scheme used by your Siemens PLC Please see your Siemens user manual for assistance with addressing scheme To set the Control Area for Siemens 1 Click the Control Notify Area tab The Control Notify Area window appears See Figure 2 6 Figure 2 6 PLC Address screen for Siemens PT Configuration x PT Type System Control Notify Area gt PT Control Area PLC Address Set Eomments PT Notify Area PLC Address Set Gonments Window Control Area PLC Address Set Eomments Cancel Help 2 Click on the Set button in the PT Control Area group box The PLC Address screen appears See Figure 2 7 18 Figure 2 7 PLC Address screen for Siemens PLC Address x Memory Type Block No DB Data Block v 0 Address 1 0 Comments Cancel Help Use the necessary addressing fields to