1. GENESIS AIA Features PureVOLT GAP Technology CREATING CLEAN AIR TO BREATHE OVERALL DIMENSIONS 21 3 8 x 13 1 4 x 27 1 4 2000WO Under Furnace Unit USER S MANUAL GENESIS CREATING CLEAN AIR TO BREATHE Welcome Your purchase of a state of the art Genesis Air system is the first step in breathing new air Our powerful G A P air purification method does much more than standard air filtration systems The G A P technology in each Genesis Air system takes contaminated air and literally transforms it into high quality clean air through a multi step technology process We thank you for your purchase and are sure you will find your new Genesis Air system to be an invaluable addition We stand behind our products and are available to answer any of your questions We urge you to fill out your registration card and send it to us today If you ever have any questions about your new system or about our line of Genesis Air products please contact us at your earliest convenience Breathe Well Genesis Air Inc GENESIS AIA CREATING CLEAN AIR TO BREATHE TABLE OF CONTENTS THE AIR WE BREATHE Something In The Air Where Conventional Filters Stop What About HEPA Filters THE UVGI DIFFERENCE What is UVGI GENESIS AIR Genesis Air GAP Technology INSTALLATION Unpacking The System Component Checklist 2000WO Unit Setup Proper Wiring Instructions PROPER USE Operati
2. UVGI light bulbs can be disposed of in the same way as regular or fluorescent light bulbs While all fluorescent and UVGI bulbs contain a trace amount of mercury the quantity is so minute that disposal is not regulated by federal standards established by the EPA the Environmental Protection Agency Individual states and provinces however have also established disposal standards Please adhere to your local regulations CAUTION Make sure the power is shut off before servicing this unit Servicing this UVGI fixture without shutting off the power risks potential skin and or eye exposure Disconnect the power by unplugging the unit from the wall outlet Page 15 22 CREATING CLEAN AIR TO BREATHE REPLACEMENT PARTS Although we do not expect you to have any recurring problems with your 2000WO unit we understand that at some point in time a replacement part may be necessary These replacement parts are readily available from our warehouse and can be shipped to you promptly Just contact us with the following information Replacement Part Number Quantity Required To minimize down time of your 2000WO 2000WO Serial Number unit pre order replacement bulbs before the Cause For Replacement Optional GA WO 01 10 11 12 13 GA DT 05 GA DT 12 current bulbs go out PART NUMBERS HOUSING LID CATALYST PREFILTER GRILLE UVGI BULB BALLAST BULB SOCKET Pa
3. disconnect power to the unit by unplugging the unit from the outlet 2 To ensure proper installation read and review these instructions and illustrations thoroughly before beginning 3 All electrical connections must be in accordance with local codes ordinances or the national electrical code WIRING DIAGRAM THE FOLLOWING DIAGRAM IS FURNISHED FOR REFERENCE 120V OUTLET BALLAST l l l l l l l l l l GREEN TERMINAL MUST BE GROUNDED EE THESE INSTRUCTIONS DO NOT COVER ALL DETAILS OR VARIATIONS IN EQUIPMENT NOR DO THEY PROVIDE FOR EVERY POSSIBLE CONTINGENCY TO BE MET IN CONNECTION WITH INSTALLATION OPERATION OR MAINTENANCE GENESIS AIR STRONGLY ADVISES ALL INSTALLATIONS BE PERFORMED BY A LICENSED ELECTRICIAN TO SATISFY LOCAL CODES Page 8 Proper Use Operating the 2000WO Unit GERY CREATING CLEAN AIR TO BREATHE UNDER FURNACE SYSTEM Once the Genesis Air 2000WO unit has been properly installed it is ready to be used The 2000WO unit is a standalone unit that will work without any outside assistance simply plug it in and the 2000WO does the rest FURNACE The 2000WO unit is designed to filter and clean air before it enters the furnace I does exactly that by using an innovative Gar system 1 As the air is passed through the prefilter grille larger airborne contaminants are
4. removed from the airstream allowing the air to pass on 2 As the filtered air is passed through the irradiation chamber the UVGI light will destroy any organic matter in the airstream including mold pollen and bacteria 3 As the air is passed through the catalyst the UVGI light will react with it and cause the photo catalysis of all organic material that may still be contained in the airstream Page 9 Maintenance Changing the GA Catalyst CREATING CLEAN AIR TO BREATHE It will become necessary from time to time to remove and change or replace the catalyst This is an easy process and can be accomplished quickly and efficiently Remove the lid by loosening the screws and slowly pulling the lid away from the unit You may hear a small click as the safety switch is released Be sure that the power cord is not caught in the lid Once the lid has been removed Sa catalyst may be removed from the housing Put the lid aside and carefully remove the catalyst Remove the catalyst by pulling gently from both ends in a Straight line If there are any snags work them out slowly with your fingertips After the used catalyst has been removed it A can be replaced Place a replacement A catalyst into the main housing by placing it G snugly against the foam padding and pressing gently with even pressure on both sides of the catalyst lt Make sure that the replacement catalyst is placed pro
5. unit are designed for a long life it may become necessary from time to time to perform maintenance on and sometimes replace these bulbs This is an easy process and can be accomplished quickly and efficiently Remove the lid by loosening the screws and slowly pulling the lid away from the unit You may hear a small click as the safety switch is released Once the face panel has been removed GAF catalyst must be removed from the housing Put the lid aside and carefully remove the catalyst by pulling firmly but gently in a straight line with while holding both sides of the catalyst Set the catalyst aside NOTE Your 2000WO unit may vary slightly from the unit shown above If this is the case it may be necessary to remove the outlet cover through a slightly different method Your Genesis Air 2000WO unit is equipped and designed to be used with two 36 Watt UVGI bulbs These bulbs are critical to the proper use and effectiveness of your system When it becomes necessary to change the bulbs follow the procedures and guidelines outlined in this section UVGI Ultraviolet Germicidal Irradiation bulbs are specifically designed for sterilization and can cause serious damage to exposed skin or eyes If handled properly and safely these bulbs can be easily replaced and disposed of CAUTION UGYI Ultraviolet energy in the C Band is an UVGI bulbs will be extremely electromagnetic wave form that destroys hot to the touch All
6. AP uses ultraviolet germicidal light in a dual role to destroy and neutralize microorganisms and to activate the photocatalyst which destroys organic compounds and odors Page 4 3 GENESIS AIR PHOTOCATALY SIS GAP Converts and breaks down harmful chemical vapors and odors Titanium Dioxide in the presence of UV light has a natural purifying effect on organic compounds odors and toxic gases of all kinds Its oxidizing effect converts chemical and biological contaminants into benign elements carbon dioxide and water vapor go or om ao Installation Unpacking Your Genesis Air System GEY CREATING CLEAN AIR TO BREATHE Your new Genesis Air 2000WO unit is ready to use or install right out of the box Simply take the unit out of the box remove all protective wrapping and pull away any protective cardboard before proceeding to the next step DO Remove all protective plastic wrap packing bubbles foam tape and cardboard before continuing with the installation Failure to remove these items could reduce the effectiveness of your 2000WO unit cause a hazard or fire and may void warranties DO NOT Do not remove any protective or aluminum tape from the ballast around the wiring or from the inside of the 2000WO unit These items UL tape electrical ties etc are provided for your safety and for the best performance from your 2000WO unit Page 5 Installation Component Checkli
7. e 24 catalyst is one of the crucial steps in keeping your 2000WO unit running effectively and efficiently Keep It Clean Proper care and maintenance of your Genesis Air 2000WO system will keep it running smoothly and efficiently If your 2000WO unit is placed in an area where it is likely to deal with heavy smoking dust or any high concentration of air contaminants the unit must be inspected more frequently than average While it is important to check the bulbs and catalyst remember that the 2000WO s first line of defense is the grille Keeping your 2000WO in good condition will help maximize it s life and efficiency CAUTION Make sure the power is shut off before servicing this unit Servicing this UVGI fixture without shutting off the power risks potential skin and or eye exposure Disconnect the power by unplugging the unit from the wall outlet Page 11 Maintenance Changing the Prefilter Grille CREATING CLEAN AIR TO BREATHE Proper maintenance of your Genesis Air 2000WO unit is simple and efficient There are two basic functions that must be carried out on a regular basis The inspection and replacement of filter and catalyst media and the inspection and replacement of the UVGI bulb The frequency of these maintenance procedures depends largely on the amount of pollution encountered in the ambient environment Changing the prefilter grille is a simple process To begin simply follow t
8. ge 16 CREATING CLEAN AIR TO BREATHE CONTACT INFORMATION We aim to serve our customers with all their needs If you ever need to contact us don t hesitate Our offices are open Monday through Friday 8am 5pm Central Time Corporate Offices GENESIS AIR INC 2714 B 82nd Street Lubbock TX 79423 Phone 806 745 7000 Fax 806 745 7079 Company Website www genesisair com For Product Literature info genesisair com For General Assistance Visit Our Website Page 17 Maintenance Log CREATING CLEAN AIR TO BREATHE Maintaining a well documented log can help keep track of how your 2000WO unit is performing Use to spaces below to document the maintenance needed DATE PART S SERVICED DESCRIPTION Page 18 CREATING CLEAN AIR TO BREATHE Write your 2000WO serial number in the space above It may be necessary to have this number available when contacting Genesis Air Serial Number Page 19 CREATING CLEAN AIR TO BREATHE Page 20
9. he instructions outlined in the previous section A 2 After used prefilter grille has been Z removed it can be replaced Place a 2 21 replacement prefilter grille into the main 2 housing by placing it snugly against the 2 foam padding Press gently but firmly 22 keeping an even pressure on both sides of IZA the prefilter grille Make sure that the replacement prefilter 2 grille is placed properly by noting the A direction of the airflow on the grille 2 2 housing There will be an arrow or similar indicator designating the airflow Proper airflow will travel from the prefilter grille section of the unit through the UVGI 22 bulb section out through the catalyst Proper airflow will travel from the prefilter grille section of the unit through the UVGI bulb section and out through the catalyst NOTE Your 2000WO unit may vary slightly from the unit shown above If this is the case some of the procedures may have to be modified The process and function of the components however will not change CAUTION Make sure the power is shut off before servicing this unit Servicing this UVGI fixture without shutting off the power risks potential skin and or eye exposure Disconnect the power by unplugging the unit from the wall outlet Page 12 Maintenance Replacing Bulbs CREATING CLEAN AIR TO BREATHE Although the UVGI bulbs shipped with your 2000WO
10. idue and dust mites are just a few examples of the pollutants that are not detained While breathing filtered air is a much better alternative to non filtered air these conventional filters are extremely limited in their effectiveness What About HEPA Filters High Efficiency Particulate Arrestance HEPA filters fill the gap in collection performance that other conventional filters leave behind These filters often provide a filtering efficiency of 99 9 since they can remove particles as small as 0 3 microns in diameter HEPA filters have proven to be very effective in containing contaminants such as lead asbestos and mold spores Although these air filters are a much better alternative to conventional air filters they alone can not be counted on for truly clean air Though HEPA technology may seem new to some HEPA filtration technology has been in existence since World War Two Moreover although HEPA filters remove many airborne contaminants their effectiveness can vary dramatically depending on the filter s construction placement and amount of air passing through the filter Moreover HEPA filters are not air purifiers They at best trap a portion of the particulate matter and hold it Some filters may also contain odor eliminating media such as charcoal but even these methods trap odors and fumes instead of eliminating them Genesis Air Systems will actually destroy organic vapors odors and numerous other contaminants per
11. manently Page 2 22 CREATING CLEAN AIR TO BREATHE THE UVGI DIFFERENCE Ultraviolet Germicidal Irradiation UVGI is a process that exposes microorganisms to ultraviolet radiation typically in the range of 2250 3020 Angstroms The use of UVGI for the sterilization of microorganisms has been studied since the 1930 s Microbes are uniquely vulnerable to the effects of light at wavelengths at or near 253 7 nanometers UV C germicidal due to the way this wavelength resonates with a microbe s molecular structure Putting it simply the quantity of energy UVGI possesses is just the right amount of energy to break organic molecular bonds When a microbe s bonds begin to break apart it causes irreparable cellular damage to bacteria molds fungi or viruses With 11 watts of output per lamp the UVGI intensity is 125 microwatts per cubic centimeter within 12 inches of each lamp Most central AC systems up to 5 tons require two lamps which give an effective UVGI intensity inside the air handler of approximately 250 microwatts Larger systems require additional lamps to maintain the required UVGI intensity levels In simple terms the UVGI process will effectively destry many organic airborne contaminants including bacteria and viruses which don t stand a chance against concentrated UVGI It s a method that s as old and natural as the sun itself There is just one catch UVGI alone is not a perfect method Alth
12. ng the 2000WO Unit MAINTENANCE Changing the Catalyst Changing The Prefilter Grille Replacing Bulbs REPLACEMENT PARTS CONTACT INFORMATION MAINTENANCE LOG NOTES Table of Contents ONDA 22 CREATING CLEAN AIR TO BREATHE THE AIR WE BREATHE Most people are spending a growing portion of their time indoors As much as 80 90 of the average American day is spent indoors Whether we are at home at work or in social settings the majority of our time is spent in enclosed areas with limited air circulation Many Americans are unaware that their daily habits are exposing them to increased levels of indoor air pollution In fact many experts believe that more Americans suffer from the effects of indoor air pollution than outdoor air pollution For many Americans that suffer from allergies asthma or other breathing troubles indoor air pollution is not a nuisance but a threat to their health and well being Where Does Indoor Pollution Come From Indoor air pollution can come from a variety of sources Some air contaminants are obvious while others are less known but equally dangerous threats to your health Examples of short term effects include irritation to the eyes nose and throat and upper respiratory infections such as bronchitis and pneumonia Other symptoms can include headaches nausea and allergic reactions Short term air pollution can aggravate the medical conditions of individuals with as
13. or instructions on bulb installation and replacement see the Replcing Bulbs section of this manual The UVGI bulbs MUST be installed for proper operation and effectiveness After installing the bulbs gently re insert the catalyst and secure the lid once more DO NOT OVER TIGHTEN SCREWS Place the 2000WO unit beneath the furnace before connecting the power cord The power cord must be firmly plugged in using a standard 120V wall outlet before operating the 2000WO unit Plugging in the 2000WO unit at this point will activate the unit and begin the cleaning process CAUTION When using your Genesis Air 2000WO system it must be plugged into a standard 120V grounded outlet DO NOT attempt to modify any electrical components or the plug itself Modifying any of the electrical components could result in user injury and or damage to the 2000WO unit NOTE Your 2000WO unit may vary slightly from the unit shown above If this is the case some of the procedures may have to be modified The process and function of the components however will not change Page 7 Installation Proper Wiring Instructions GERY CREATING CLEAN AIR TO BREATHE WIRING Your 2000WO unit is designed to be plugged in to a standard 120V wall outlet It may however become necessary to change the ballast or perform maintenance work in which the schematic and information below would be beneficial GENERAL 1 Before starting the installation
14. ough many organic contaminants can be destroyed easily and effectively pollutants such as particulate matter smoke and inorganic gases won t be stopped with UVGI Once again something s got to fill the GAP Page 3 nN 5 GENESIS AIR PHOTOCATALYS S CREATING CLEAN AIR TO BREATHE Genesis Air incorporates a revolutionary technology to clean deodorize and disinfect the air This is a three step synergistic approach to achieve air quality like never before Our G A P technology offers Proven Leading Edge Technology Rationalized Design For Application Specific Products G A P Does Not Produce Harmful By Products There is No Accumulation of Contaminants Oxidizes Organic Substances Into Benign Components Value Priced Low Maintenance Costs Long Lifetime Components 1 ADVANCED FILTRATION Removes even particles you can t see New high efficiency high capacity low resistance particle filter removes most pollen mold mildew ragweed dust mites house dust bacteria pet dander and many other submicroscopic poisons allergens and irritants 2 UVGI TECHNOLOGY 10 000 times the power of the Sun eradicate most airborne bacteria viruses mold spores and fungi Ultraviolet light has been used for years in hospitals and critical situations to kill bacteria virus and other contaminants Its benefits are proven and well known Now Genesis Air Photocatalysis G
15. ow the microorganisms It is produced when mercury vapors bulbs to cool before attempting are exposed to high voltage energy called plasma to clean or replace the bulbs This plasma is what produces the blue light glowing in our tubes CAUTION Make sure the power is shut off before servicing this unit Servicing this UVGI fixture without shutting off the power risks potential skin and or eye exposure Disconnect the power by unplugging the unit from the wall outlet Page 13 Maintenance Replacing Bulbs cont GEY CREATING CLEAN AIR TO BREATHE CAUTION UVGI bulbs will be extremely hot to the touch Allow the bulbs to cool before attempting to clean or replace the bulbs To ensure effective and safe operation UVGI fixtures must be inspected on a quarterly basis or more often if indicated by lamp cleanliness and lamp failure due to the operating environment or conditions UV working lamps should never be handled with bare fingers always wear soft cotton gloves when handling working lamps to prevent oily deposits that decrease lamp efficiency and lamp All UVGI systems must be inactivated prior to maintenance renovation or repair work or when accessing ventilation ducts where UVGI systems have been installed If it is not possible or feasible to turn the UVGI systems OFF to perform necessary tasks appropriate personal protective equipment PPE must be worn The following procedure must be followed at all
16. perly by noting the direction of the airflow on the catalyst housing There will be an arrow or similar indicator designating the airflow Proper airflow will travel from the prefilter grille section of the unit through the UVGI bulb section and out through the catalyst Replace the lid and properly secure it in place once more being careful not to snag SE the power cord NOTE Your 2000WO unit may vary slightly from the unit shown above If this is the case some of the procedures may have to be modified The process and function of the components however will not change CAUTION Make sure the power is shut off before servicing this unit Servicing this UVGI fixture without shutting off the power risks potential skin and or eye exposure Disconnect the power by unplugging the unit from the wall outlet Page 10 Proper Use Changing the GA Catalyst GERY CREATING CLEAN AIR TO BREATHE Changing the Catalyst cont The Genesis Air GAP catalyst will need to be changed in time due to the photo catalyzing properties of the material As the catalyst assists in the destruction of harmful and potentially hazardous air contaminants they are chemically changed to benign substances carbon and water vapor In time this carbon buildup will accumulate on the catalyst medium and could hamper the effectiveness of your 2000WO unit Proper maintenance cleaning and changing of th
17. st CREATING CLEAN AIR TO BREATHE GA WO 10 LID 2 e x PREFILTER GRILLE SN A GA WO 11 CATALYST GA WO 13 UVGI BULBS GA WO 01 Boxed and located U HOUSING within the Main Housing Use this checklist to make sure your new Genesis Air 2000WO unit arrived intact Please note that the UVGI bulb will not arrive installed Open the 2000WO unit by removing the screws on the lid and removing the catalyst Once the catalyst has been removed the bulbs can be removed and installed Make sure to remove all packaging before continuing NOTE Your 2000WO may vary slightly from the unit shown above however all components will be essentially the same Page 6 Installation 2000W Unit Setup CREATING CLEAN AIR TO BREATHE DO NOT PLUG IN THE 2000WO UNIT UNTIL IT HAS BEEN SET UP COMPLETELY AND IS IN PLACE UNDER THE FURNACE The Genesis Air 2000WO unit is designed to be used as a standalone under furnace unit The 2000WO system must be plugged into a standard wall outlet to function NOTE The UVGI bulbs are located within the main housing Remove the lid A by undoing the screws located at the top of the unit Second remove the catalyst B by gently pulling it out evenly from both ends Removing the catalyst allows access to the inside of the main housing area and the bulbs Remove the bulbs D from the packaging and install the UVGI bulbs F
18. thma and emphysema In the great Smog Disaster in London in 1952 four thousand people died in a few days due to the high concentrations of pollution Long term health effects can include chronic respiratory disease lung cancer heart disease and even damage to the brain nerves liver or kidneys Continual exposure to air pollution affects the lungs of growing children and may aggravate or complicate medical conditions in the elderly The sources of indoor air pollution are varied with some being more obvious than others Tobacco smoke cooking and heating appliances and vapors from building materials paints furniture etc cause pollution inside buildings As these contaminants enter our daily environments the lack of air circulation leaves them to settle and accumulate In time these contaminants could accumulate in more than just ventilation systems these contaminants left to settle could accumulate within a person s body Page 1 CREATING CLEAN AIR TO BREATHE Where Conventional Filters Stop Where Conventional Filters Stop A conventional air filter works by simply trapping air debris and particulate matter in an airstream that are too large to pass through the filter While larger particulate matter may be trapped by one of these conventional filters the smaller and often more harmful matter can easily slip through the gaps that exist in these filters Airborne bacteria molds pollen chemical res
19. times Turn OFF power to the 2000 P unit Depending on the installation a circuit switch may be used or the appropriate fuse may be removed Verify that the lamps are OFF by observing the fixture from a distance There should not be a blue glow if the units are OFF Open the unit according to the instructions in this manual Remove the lamps from the unit for cleaning Wearing soft cotton gloves and using a cloth dampened with alcohol clean each lamp and reflector All dust and other deposits should be removed since they reduce the effectiveness of the UV lamps While still wearing cotton gloves to prevent oily deposits replace the lamp tubes in the unit Page 14 Maintenance Replacing Bulbs cont GEY CREATING CLEAN AIR TO BREATHE Replace old lamps with new lamps if any of the following conditions exists Prior to the manufacturer s expected life rating of 9000 burning hours of usage When tubes stop glowing When they flicker to an objectionable extent or if there is a drastic reduction in output measurement from the previous quarterly inspection Replace and secure the outlet cover in place once more Turn power ON the unit and verify lamp operation Document the inspection cleaning and lamp replacement in the a Preventive Maintenance Record To replace the bulb depress the TABS on either side of the base Slide the bulb out carefully and replace in a similar fashion Bulb Disposal In most states