Home

EN Features Box Content Layout General information Use

image

Contents

1. eticer Wild instinct of Technology SOS ES S6A Indoor Siren www etiger com Features The ES S6A can be used either as an additional siren connected to your alarm system or as an independent siren connected to a remote control and or wireless detectors Wireless connection for an easy installation Radio frequency security of the accessories more than one million of codes combinations Simplified connection to accessories Can be connected to all of eTiger Secual accessories Built in 4 2V 600 mAh lithium batteries 8 hour battery life in standby mode Box Content 1 x ES S6A 1 x User Manual Layout Switch Power Connect General information The ES S6A is powered by its built in AC 220V plug Several ES S6A can be installed throughout your home and connected to your alarm system When the alarm of your system is triggered the ES S6A rings out and its LEDs switch on The ES S6A can also be used as a standalone siren and can be connected to wireless sensors and or to a remote control Power on off Power on The siren is powered off as per default settings Plug the siren to a 220V socket and press the Power button on the siren You hear a long beep the siren is on You can also turn the siren on by long pressing 6 seconds the Power button on the siren Enter Setup Mode Power off Enter Setup Mode by pressing the power button once Press again the P
2. must be connected to a remote control or an accessory e g motion detector door window contact When the system is armed if a sensor is triggered the siren will ring out and the LED lights will turn on Connect a remote control Press the Connect Button on the siren The siren beeps once and the LEDs light up the siren is now in Connection Mode Press any button on the remote control You hear one beep the remote control has been connected to the siren successfully if you hear 3 beeps the remote control has already been connected Connect a wireless sensor Press the Connect Button on the siren The siren beeps once and the LEDs light up the siren is now in Connection Mode Trigger the sensor e g walk in front of the sensor if you want to connect a motion detector You hear one beep the accessory has been connected to the siren successfully if you hear 3 beeps the accessory has already been connected The siren supports up to 10 remote controls and 10 wireless detectors Test a Test the connection to a remote control Press the Arm button on the remote control The siren beeps once the connection of the remote control is successful If not the connection has failed try registering the remote control again b Test the connection to a wireless sensor Arm the system Trigger the sensor e g walk in front of the sensor if you have connected a motion detector The siren rings out the connection o
3. be light turns into a night lamp Press the Stay button twice then the Arm button once the siren is in monitoring mode with night lamp on Press the Disarm button the siren is disarmed and the LED lights switch off Specifications Power supply Radio frequency 220V 315MHz or 433MHz 75KHz Volume 90dB Housing material ABS plastic Backup battery 4 2V 600mA Lithium Operating conditions Temperature 10 C 55 C Static current Relative Humidity lt 80 lt 13mA non condensing Alarm current Dimensions lt 300mA 81x 80x 76mm Standards x This product bears the selective sorting symbol for waste electrical and electronic equipment WEEE This means that this product must be handled pursuant to European Directive 2002 96 EC in order to be recycled or dismantled to minimize its impact on the environment For further information please contact your local or regional authorities Electronic products not included in the selective sorting process are potentially dangerous for the environment and human health due to the presence of hazardous substances cE In compliance with European laws orons This product was designed and manufactured in compliance with Directive 2002 95 EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equipment RoHS Directive RoHS and is deemed to comply with the maximum concentration
4. f the sensor is successful If not the connection has failed try registering the sensor again Clear all accessories Press the Connect button on the siren for 6 seconds until you hear two beeps The LEDs blink twice all the accessories connected to the siren have been cleared Entry Exit Delay A delay before activation can be set for the siren if the sensor is assigned to Single Delay Zone If the Entry Exit Delay is activated the siren beeps once every second until the system is armed during the period of delay set If one of your system s sensors triggers the alarm the ringing out of the siren will be delayed accordingly Set up the delay Enter Setup Mode by pressing the power button once Press the power button again once to set the delay to 10 seconds twice to set the delay to 20 seconds three times to set the delay to 30 seconds four times to deactivate the delay Default setting no delay The delay will be effective only if the sensors have been assigned to the Single Delay Zone To assign a sensor to the Single Delay Zone open its cover and move the jumpers on the circuit board according to the opposite drawing For more information refer to the manual of your alarm system D3 Night Lamp mode When used as a standalone alarm system the ES S6A can also be used as an LED night lamp Press the Stay button on the remote control twice the siren switches to Home Mode and the stro
5. ower button for 6 seconds to turn the siren off Siren and light indications When arming the system The siren beeps once the LED lights blink once and switch on When disarming the system The siren beeps twice the LED lights blink twice and turn off When armed disarmed in Mute Mode from the control panel The siren does not beep the LED lights do not blink Use as an additional siren If the siren is used as an additional siren it must be registered to your alarm s control panel If the alarm is triggered the ES S6A will ring out and its LED lights will turn on Register the ES S6A in the control panel Press the Connect Button on the siren The siren beeps once and the LEDs light up the siren is now in Connection Mode Press the SOS or Arm button on the control panel of your alarm system You hear one beep the siren has been registered in the control panel successfully if you hear 3 beeps the siren has already been connected Press the Connect Button again on the siren to exit the connection mode Note Do not trigger an alarm with a sensor when registering the siren in the control panel Test Press the Arm button on the remote control Both the built in siren of the control panel and the ES S6A beep the connection is successful If not the connection has failed try registering the siren again Use as a standalone alarm system Before using the ES S6A as a standalone alarm system it
6. values set by the European Technical Adaptation Committee TAC Manufactured in China Images illustrations and text are non contractual ETIGER and the ETIGER logo are registered trademarks and the property of ETIGER Copyright 2014 ETIGER All rights reserved etTicerR Wild instinct of Technology This user manual is available in other languages at www etiger com eu support m h m ETIGER EUROPE Rue de la Loi 25 7100 La Louvi re Belgique service etiger com ES S6A UM EN20140724 2 0 W

Download Pdf Manuals

image

Related Search

Related Contents

Compact NSX 100-630 A - User Manual    Tripp Lite SR14 User's Manual  Logging On to iProcurement  Arctic Cove MAC512CT Use and Care Manual  Brochure de la saison 2012 -2013 de la Maison de la Musique de  Data Logging Rain Gauge RG3 and RG3  110_110HD  User Guide - Fedora Documentation  Emerson LK59FSST User's Manual  