Home

iPC- Plus Series PCs

image

Contents

1. AND D HAZARDOUS LOCATIONS OR NONHAZARDOUS LOCATIONS ONLY FOR USE ON A FLAT SURFACE OF A TYPE 1 ENCLOSURE WITH PROVISIONS FOR CLASS DIVISION 2 WIRING METHODS TEMPERATURE CODE T5 Document DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 12 of 28 NOTE RACK MOUNT VERSIONS SUITABLE FOR USE IN CLASS I DIVISION 2 GROUPS A B C AND D CLASS II DIVISION 2 GROUPS F AND G CLASS Ill HAZARDOUS LOCATIONS OR NONHAZARDOUS LOCATIONS ONLY FOR RACK MOUNT INSTALLATION ON A TYPE 1 ENCLOSURE WITH PROVISIONS FOR CLASS DIVISION 2 WIRING METHODS TEMPERATURE CODE T5 NOTE ENCLOSED EPC VERSIONS A LISTED VESA STYLE MOUNT SUITABLE WITH A MINIMUM LOAD RATING OF 40 POUNDS SHALL BE USED IN THE END INSTALLATION FOR USE IN NONHAZARDOUS LOCATIONS ONLY TYPE 1 ENCLOSURE WARNING EXPLOSION HAZARD SUBSTITUTION OF ANY COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 13 of 28 WARNING EXPLOSION HAZARD DO DISCONNECT EQUIPMENT UNLESS THE POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS PS 2 AND AUDIO CONNECTORS ARE FOR SETUP AND MAINTENANCE ONLY USB CONNECTIONS MUST BE SECURED WITH INCLUDED RETENTION BRACKET SEE INSTA
2. DOC IPC 005 User Manual iPC Plus amp nPC400 Rev Rel 1 2015 Page 3 of 28 Specifications Front Panels The iPC Plus series has NEMA 4 4X 12 sealed front panels when mounted an appropriate NEMA rated enclosure See Chapter 2 for more details on installation and selection of an appropriate enclosure All three sizes have very similar front panels with different dimensions i 2 1e A 3 F i580 17 14 LM iPC1550 iPC1750 iPC1950 L 2312 515124 iPC1550KP Figure 1 0 iPC Plus Series Front Panel Comparison The standard front panels are powder coated aluminum The optional Stainless Steel front panel is type 304 and will not contain a logo pocket or logo on the front The window area is clear polycarbonate when ordered without a touchscreen The touchscreen option is heat annealed glass covered by a polyester overlay The polyester overlay has better resistance to chemicals than the polycarbonate window Depending on the chemicals involved in your application consideration should be given to choosing the proper window material In addition to the panel mounted versions there is a display less node version the nPC400 This unit is essentially the same as the other iPC Plus units without a NEMA sealed front panel touchscreen and display It is intended to be mounted inside a NEMA enclosu
3. 00000 xo m m COM2 RS 232 422 485 j o USB 2 0 O 55322 rM USB 3 0 USB 3 0 223 05830 MICROPHONE RS 232 RS 232 MODE DEFAULT RG 422 405 MODE PIN SIGNAL PIN SIGNAL PIN SIGNAL PIN SIGNAL PIN com EB ES 2 RO RS 11589 3 TD 8 CIS SELECT 3 90 8 CTS 3 mor 5 END gt INBOS 5 5 GND 178A0416 REV B Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev Rel 1 2015 Page 28 of 28
4. On these units you will need an USB DVD ROM Follow the instructions on the recovery DVD for installation When installing the image from this DVD it will not be Activated unlike when you received the unit You may need to set the video resolution after loading the image depending on the unit you are loading Windows 7 Professional 32 bit and Windows 7 Ultimate 64 bit In a similar manner to Windows XP Windows 7 Professional and Windows 7 Ultimate are also supplied with a system recovery disk This recovery disk installs the factory image with all drivers installed On these units you will need an USB DVD ROM Follow the instructions on the recovery DVD for installation When installing the image from this DVD it will not be Activated unlike when you received the unit You may need to set the video resolution after loading the image depending on the unit you are loading Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 27 of 28 Chapter iPC Plus CPU and BIOS Consult the iPC Plus Series CPU Board User manual for more detailed specifications of the CPU board and BIOS details This section will concentrate on the features of the iPC Plus Series units that are externally accessible In addition any internal details that may need adjusting will be discussed External I O Connections The following figures show the externally accessible connections Pinouts VGA GLAN GLAN ar 6
5. Rel 1 2015 Page 24 of 28 WARNING EXPLOSION HAZARD DO DISCONNECT EQUIPMENT UNLESS THE POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS PS 2 AND AUDIO CONNECTORS ARE FOR SETUP AND MAINTENANCE ONLY USB CONNECTIONS MUST BE SECURED WITH INCLUDED RETENTION BRACKET SEE INSTALLATION INSTRUCTIONS ATTENTION RISQUE D EXPLOSION NE PAS BRANCHER OU DEBRANCHER L APPAREIL A MOINS QUE L ALIMENTATION A ETE COUPEE OU SI LA ZONE N EST PAS HAZARDEUSE LE CONNECTEUR 5 2 LINE LINE OUT ET CONNECTEURS DU MICROPHONE SI PRESENTS SONT DESTINES A LA CONFIGURATION ET MAINTENANCE SEULEMENT VOIR INSTRUCTIONS DE MONTAGE ADVERTENCIA PELIGRO DE EXPLOSION NO DESCONECTE EL EQUIPO A MENOS QUE LA ALIMENTACION ELECTRICA HAYA SIDO DESCONECTADA O EL AREA SE CONSIDERE NO PELIGROSA LOS CONECTORES PS 2 ENTRADA Y SALIDA DE LINEA DE AUDIO Y MIC SI ESTA PRESENTE SON PARA CONFIGURACION Y MANTENIMIENTO SOLAMENTE VEALAS INSTRUCCIONES DE INSTALACION WARNUNG EXPLOSIONSGEFAHR NICHT ANSCHLIEBEN ODER ABKLEMMEN BEVOR DIE KAMERA SICH ABGESCHALTET HAT ODER DER BEREICH NICHT MEHR GEFAHRDET IST PS 2 LINE IN LINE OUT MIC UND STECKER FALLS VORHANDEN NUR FUR INSTALLATION UND WARTUNG VERWENDEN SIEHE MONTAGEANLEITUNG Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 25 of 28 Hard Drive Removal and Replacement These products are equipped with an easily removable SATA
6. additional I O or expansion options Any additional I O installed during application can increase this value ENVIROMENTAL 20 to 80 RH noncondensing Operating Vibration 5 2000 Hz 0 006 peak to peak displacement 1g maximum acceleration Non Operating Vibration 5 2000 Hz ra Operating Altitude Sea level 10 000 feet Non Operating Altitude Sea level 40 000 feet 1 Shock and Vibration specifications are established using Solid State drives and non rotating media 2 Altitude Specification is established by using all internal component specifications Document No DOC IPC 005 User Manual iPC Plus amp 400 Rev A Rel 1 2015 Page 11 of 28 Front Panel NEMA Rating NEMA 4 4X 12 IP66 EU CE Marking Compliance CE EN 55022 Class A EN 61000 3 2 Class A EN 61000 3 3 EN 61000 6 2 Safety Agency Approvals UL 508 Listed ANSI ISA 12 12 01 2012 Listed cUL Listed CSA 22 2 142 CSA 22 2 143 See appropriate note below for the applicable unit or option being utilized NOTE PANEL MOUNT VERSIONS SUITABLE FOR USE IN CLASS I DIVISION 2 GROUPS A B C AND D CLASS II DIVISION 2 GROUPS F AND G CLASS Ill HAZARDOUS LOCATIONS OR NONHAZARDOUS LOCATIONS ONLY FOR USE ON A FLAT SURFACE OF A TYPE 1 4 4X OR 12 ENCLOSURE WITH PROVISIONS FOR CLASS DIVISION 2 WIRING METHODS TEMPERATURE CODE T5 NOTE NPC400 UNITS SUITABLE FOR USE IN CLASS I DIVISION 2 GROUPS A
7. gt TIGHTENTO8 gt INCH POUNDS FRONT PANEL OF NEMA ENCLOSURE 1 M d 2322 Bess U 00 lI u I I 1 EH 2 1 S 1 12 7 J 7 EJ 17 EH REAR VIEW OF PANEL MOUNTED PC Plus NOTE WHEN INSTALLING THE MOUNTING CLIPS TIGHTEN THE SCREWS TO 8 10 INCH POUNDS MAXIMUM OVERTIGHTENING THE SCREWS WILL RESULT IN A COMPRIMISED NEMA SEAL AND MAY CAUSE TOUCH SCREEN BREAKAGE Document DOC IPC 005 User Manual iPC Plus amp 400 Rev A Rel 1 2015 Page 18 of 28 nPC400 Unit Installation The nPC400 is intended to be mounted on the flat surface on the inside of a NEMA Type 1 4 4x or NEMA 12 enclosure See the specifications section for the dimensions and mounting dimensions required for mounting this unit When selecting an enclosure remember to allow adequate space around the computer for good air flow Do not block air flow around the unit except for the mounting surface The computer can be mounted on a horizontally or vertically to a wall or shelf within the enclosure The unit is designed to work in environments up to 50 degrees Centigrade ambient temperature inside the enclosure Remember to account for heat dissipated from other equipment that may be installed inside the same enclosure Rack Mount Unit Installation The iPC1950 with a rack mount front panel is intended to be mounted to a 19 0 wide rack in a NEMA Type 1 or better enclosure The unit can be mounted usi
8. prong cord is supplied If another country connection method is required then an appropriate UL recognized power cord can be chosen locally not supplied by Nematron Optionally available is an IEC type connector that can be directly wired to for field wiring This can be ordered separately from Nematron and is part number PWR AC EN Enclosed ePC Series IEC Power Cable Power Cable Retention Clip Installed 10 Cable Management The iPC Plus units include a retention mechanism for securing USB connections USB connections are not secure and can easily fall out The use of this mechanism is suggested for all applications and is required for any hazardous locations installations Simply remove the bracket insert your USB cables through the bracket Connect your USB cables to the unit and move the bracket into position Snugly push the bracket toward the USB connector and secure with the screw provided On the iPC panel mount Rack Mount and Enclosed units the USB bracket is a simple L shaped bracket with cutouts to retain up to four USB cables and a mounting screw On the 400 the bracket is two pieces one flat piece is secured to the bottom of the unit using two 44 40 screws and then the other functions the same as the ePC Series USB retention bracket Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 23 of 28 Video and the Serial connections have jack screws in the connectors that be utilized
9. 550T i7 16GB 80SS DVD 2P W7 DC Because the iPC Plus not EN option is UL listed for Hazardous Location use Class Division2 Groups A B C D Class II Division 2 Groups F and G Temperature Code T5 the units do not have a power switch for switching off supplied power Consideration should be give to the installation of an appropriately rated external power switch if the application requires powering off the iPC Series unit Power is connected to the units through a removable Phoenix Contact plug Phoenix Contact P N 1777992 that allows for screw termination of field wiring This plug is included with each unit and is keyed to prevent installation in a unit with the wrong input voltage rating When Field Wiring to these terminals the use of 18 AWG or greater 12 AWG maximum copper wire with 60 C or 60 75 C wire insulation and the terminal tightening torque of 7 0 Ib in 0 79 Nm is required The terminal screws are shown in Top View below Connect the field wiring according to the appropriate voltage in the table below Strip the wire insulation back on each conductor 6 5 mm 0 26 in and assure that the remaining wire is twisted together not frayed and clean If an outer jacket over each conductor is utilized then strip the outer jacket back an additional 19 0 mm 0 75 in as shown in figure below When installing the conductors take care that there are not any stray strands of wire that can contact an adjoining connection Tinning
10. 8mm x 378 5mm x 314 2mm 415 3mm 450 9mm Weight 20 0 Ibs 9 07kg 25 0 Ibs 11 33kg 24 0 Ibs 10 88kg 28 0 Ibs 12 7kg Document No DOC IPC 005 User Manual iPC Plus amp 400 Rev A Rel 1 2015 Page 9 of 28 iPC1550 iPC1550KP iPC1750 iPC1950 Shipping Weight 25 0 Ibs 11 33kg 30 0 Ibs 13 6 kg 29 0 lbs 13 25kg 33 0 Ibs 14 96kg Option Weight 43 5 lbs 1 58kg N A 43 75 lbs 1 7kg 4 0 Ibs 1 81kg SS Additioanl weight for Stainless Steel Front Panel option The 400 is essentially the rear of the panel mount versions It is supplied with mounting brackets so that it can be easily attached to wall or shelf in NEMA 1 or better enclosure The 400 is not a standalone device as the EN units and must be installed in an enclosure to protect operators The dimensions of the 400 unit are as follows C C C C C C C C C C ccc c cC C c c c lt c cc c cc cc C CL CC CCc UC T CL CL CL CL CL C 1 GD c ccc 15 65 397 5 15 07 381 0 Document DOC IPC 005 User Manual iPC Plus 400 Rev Rel 1 2015 Page 10 of 28 ELECTRICAL Input Power nPC400 60 W Typical iPC 1550 70 W Typical iPC1550KP 70 W Typical iPC1750 80 W Typical iPC1950 90 W Typical Typical Power is measured without any
11. F1 F20 Alpha and Symbols not changeable Relegendable Reprogrammable Relegendable Reprogrammable Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 5 of 28 Each of these sections has specific functions explained below Keypad Section Description ATM style Screen Keys These keys are on each side of the screen and can be directly tied to a specific screen application much like an ATM These keys are reprogrammable but are not able to be re legended Left Keys are defined as SC1 through SC8 top to bottom the default key returns for SC1 SC8 are CTRL F1 F8 respectively Right Keys are defined as SC9 through SC16 top to bottom the default key returns for SC9 SC16 are ALT F1 F8 respectively Function Keys The 20 keys directly below the screen are normally Function keys The Function keys are reprogrammable and can be re legended They also have Alpha characters in the top left and right corner of each key These Alpha characters and symbols are not reprogrammable and cannot be removed by changing the legend strips The default key returns for F1 F10 are F1 F10 respectively The default key returns for F11 F20 are SHIFT F1 F10 respectively These keys are multi functional and can return Alpha Symbols and or Function keys See the explanation of Mode and Led Keys below System Keys The 6 keys in the lower right corne
12. LLATION INSTRUCTIONS ATTENTION RISQUE D EXPLOSION NE PAS BRANCHER OU D BRANCHER L APPAREIL MOINS QUE L ALIMENTATION T COUP E OU SI LA ZONE N EST PAS HAZARDEUSE LE CONNECTEUR PS 2 LINE IN LINE OUT ET CONNECTEURS DU MICROPHONE SI PR SENTS SONT DESTIN S LA CONFIGURATION ET MAINTENANCE SEULEMENT VOIR INSTRUCTIONS DE MONTAGE ADVERTENCIA PELIGRO DE EXPLOSI N NO CONECTE NI DESCONECTE EL EQUIPO A MENOS QUE LA ALIMENTACION EL CTRICA HAYA SIDO DESCONECTADA O EL AREA SE CONSIDERE NO PELIGROSA LOS CONECTORES PS 2 ENTRADA Y SALIDA DE LINEA DE AUDIO Y MIC SI ESTA PRESENTE SON PARA CONFIGURACION Y MANTENIMIENTO SOLAMENTE VEALAS INSTRUCCIONES DE INSTALACION WARNUNG EXPLOSIONSGEFAHR NICHT ANSCHLIEBEN ODER ABKLEMMEN BEVOR DIE KAMERA SICH ABGESCHALTET HAT ODER DER BEREICH NICHT MEHR GEFAHRDET IST PS 2 LINE IN LINE OUT MIC UND STECKER FALLS VORHANDEN NUR F R INSTALLATION UND WARTUNG VERWENDEN SIEHE MONTAGEANLEITUNG Document No DOC IPC 005 User Manual iPC Plus amp 400 Rev A Rel 1 2015 Page 14 of 28 Chapter 2 Installation of Computer The panel mount versions of the iPC Plus units are intended to be mounted in and used where NEMA 1 NEMA 4 4x and NEMA 12 type enclosures are employed Enclosures made of heavier gauge metal work better because they won t deform or bend as easily when the monitors sealing gasket is compressed The monitor meets NEMA 4 12 sealing specifications when properly in
13. N OF VIDEO AND OR SERIAL TOUCHSCREEN CABLES ASSURE THAT THE THUBSCREWS ARE SUFFICIENTLY TIGHTENED WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS THE POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS 5 2 AND AUDIO CONNECTORS ARE FOR SETUP AND MAINTENANCE ONLY USB CONNECTIONS MUST BE SECURED WITH INCLUDED RETENTION BRACKET SEE INSTALLATION INSTRUCTIONS ATTENTION RISQUE D EXPLOSION NE PAS BRANCHER OU D BRANCHER L APPAREIL MOINS QUE L ALIMENTATION T COUP E OU SI LA ZONE N EST PAS HAZARDEUSE LE CONNECTEUR PS 2 LINE IN LINE OUT ET CONNECTEURS DU MICROPHONE SI PR SENTS SONT DESTIN S LA CONFIGURATION ET MAINTENANCE SEULEMENT VOIR INSTRUCTIONS DE MONTAGE ADVERTENCIA PELIGRO DE EXPLOSI N NO CONECTE NI DESCONECTE EL EQUIPO A MENOS QUE LA ALIMENTACION EL CTRICA HAYA SIDO DESCONECTADA O EL AREA SE CONSIDERE NO PELIGROSA LOS CONECTORES PS 2 ENTRADA Y SALIDA DE L NEA DE AUDIO Y MIC SI EST PRESENTE SON PARA CONFIGURACI N Y MANTENIMIENTO SOLAMENTE VEALAS INSTRUCCIONES DE INSTALACION WARNUNG EXPLOSIONSGEFAHR NICHT ANSCHLIEBEN ODER ABKLEMMEN BEVOR DIE KAMERA SICH ABGESCHALTET HAT ODER DER BEREICH NICHT MEHR GEFAHRDET IST PS 2 LINE IN LINE OUT MIC UND STECKER FALLS VORHANDEN NUR F R INSTALLATION UND WARTUNG VERWE
14. NDEN SIEHE MONTAGEANLEITUNG Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 21 of 28 Protective Cover Installation Optional if desired Step 1 Gather the parts of the protective cover top shell bottom shell label insert and wire tie The picture shows wire tie top label insert right bottom shell left and top shell lower right Step 2 Insert your pre wired connector with the screws facing up into the bottom shell See manual for cable wiring instructions Step 3 Insert the wire tie from the bottom shell loop around the cable and come back out of the opposite hole in the bottom shell Step 4 Tighten the wire tie around the cable and the bottom shell Step 5 Seat the top shell onto the bottom as shown Insert label strip if desired in slot on top shell and bottom shell Step 6 Snap the top and bottom shells together Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 22 of 28 Connecting Power to Enclosed units The enclosed iPC Plus units are powered from 100 240 VAC 50 60 Hz only Because these are stand alone Type 1 devices and do not require an additional NEMA type enclosure a different type power connection is required These units use a more standard IEC type power cord like found on most computers There is a retention clip that can be utilized to help retain the cord from falling out A US three
15. PC1550KP iPC1550KPT Industrial Computer 1237 02 17 40 02 Cutout Pattern for iPC1750 iPC1750T Industrial Computer i 13 70 02 16 35 02 Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 16 of 28 Cutout Pattern for iPC1950 1950 industrial Computer 14 90 02 17 75 02 Document DOC IPC 005 User Manual iPC Plus amp nPC400 Rev Rel 1 2015 Page 17 of 28 Mounting Clip Installation _ 25 THICK MONITOR FRONT BEZEL P COMPRESSABLE NEMA SEALING GASKET n RUN MOUNTING CLIP WITH 10x32 SCREW ALLOWABLE mE PANEL THICKNESS CUT AWAY FRONT PANEL ENCLOSURE
16. hard drive They are designed so that there is no need to remove the cover on these units to change a hard drive The hard drive is simply removed by loosening the two thumbscrews and pulling the drive out Remove all power to the unit before removing the drive There are no cables to remove when pulling the drive from the chassis Once the drive is removed there are four screws on the back of the bracket that hold the drive If the drive is being replaced these screws secure the drive to the plate To reinstall the drive simply insert the bracket with hard drive attached into the chassis and slide forward Completely push the drive in and secure the thumbscrews before reapplying power to the unit Various hard drive options with a mounting bracket pre installed are available for purchase from Nematron If a spare hard drive is required these are recommended These spare hard drives can be used with third party software to create complete system backups for your installation Hard Drive Removal Installing the Touch Screen Driver Software If your ePC is ordered with a touchscreen and an operating system the drivers will be pre installed The ePC Series utilizes a USB connection for the touchscreen therefore the touchscreen will only function with operating systems that can recognize and utilize USB connections The driver included with these units functions with Windows 2000 XP VISTA and Windows 7 If using the nPC200 with a touchscreen moni
17. iPC Plus amp 4PC400 High Performance Ultra Thin Industrial Computers User s Guide Document No DOC IPC 005 N t User Manual iPC Plus amp 400 Rev A Rel 1 2015 el la Revision List Revision Number Description of Change Release Date A Initial Release 1 2015 Nematron reserves the right to make changes in specifications described herein at any time without notice in order to improve design and reliability Nematron does not assume any responsibility for the use of any circuitry described no circuit patent licenses are implied Nematron assumes no responsibility for damage caused by misuse or improper use of its products WARRANTY Nematron warrants to Customer that the Products will be free from defects in material and workmanship under normal use and service for a period of two years from date of invoice Customer s exclusive remedy for breach of this warranty is that Nematron will either i repair or replace at its option any Product which fails during the warranty period because of such defect if Customer promptly reported the failure to Nematron in writing or ii if Nematron is unable to repair or replace Nematron will refund the purchase price of the Product upon its return to Nematron This warranty does not apply to any Product which has been subjected to misuse abnormal service or handling or which has been altered or modified in design or construction or which has bee
18. lters should be carefully removed and cleaned periodically depending on service conditions In some applications this may need to be checked and cleaned often These units are designed to work in environments up to 50 degrees Centigrade ambient temperature around the enclosure Impeding the airflow around this unit or clogged filters will severely affect the reliability of the unit by raising the internal temperature Assure that there is adequate airflow around the unit NEMA Type 1 is not sealed against water and or dust it is simply provides protection from operators shocking themselves It also offers a certain amount of fire containment it the event of a catastrophic failure inside the unit As stated previously NEMA 1 is not waterproof or dust proof and is not intended to be utilized in environments exhibiting high levels of these conditions Example of an Enclosed Unit Mounted To a Stand Document DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 19 of 28 Connecting Power to the iPC Plus Connecting power to the Panel Mount Rack Mount and nPC120 units The iPC Plus and nPC400 units are powered from 100 240 VAC 50 60 Hz or optionally from 24 VDC Damage will occur if 100 240 VAC power is connected to an iPC Plus unit equipped with the 24 VDC input power option iPC Plus equipped units with the 24 VDC option will have a DC suffix in their model number such as iPC1550 CP4500 2GB HD DVD XP DC or PC1
19. mm 19 0 482 6mm Display Size Active 11 97 x 8 98 13 30 x 10 64 14 82 x 11 85 Area H x V 304 0mm x 228 1mm 337 8mm x 270 3mm 376 4mm x 301 0mm Native Resolution XGA 1024 x 768 SXGA 1280 x 1024 SXGA 1280 x 1024 Displayable Colors 16M 16M 16M Brightness Typical 300 Nit 380 Nit 300 Nit Contrast Ratio Typical 800 1 1000 1 2000 1 Horizon Vertical View 150 145 176 170 178 178 Angle CR gt 5 Typical Backlight Life Typical 50 000 hrs 50 000 hrs 50 000 hrs TOUCH SCREEN Optional Touch Screen Technology Interface Resolution Positional Accuracy Maximum Error Positional Accuracy Standard Deviation of Error Expected Life 5 Wire Analog Resistive Internally via USB 4096 x 4096 0 18 0 19 1900 4 57mm 4 83 1900 lt 0 08 lt 2 0 gt 35 000 000 Activations PHYSICAL iPC1550 iPC1550KP iPC1750 1950 Over All 12 80 x 15 80 x 13 98 x 19 0 x 14 48 x 17 14 x 15 70 x 18 66 x Dimensions 4 55 4 65 4 55 4 70 HxW x D 325 1 855 1mm x 367 8mm x 898 8mm x 401 3mm x 482 6mm x 435 4 x 474 0mm x 115 6mm 117 5mm 115 6mm 119 4mm Panel Mounting Depth 4 3 109 2mm 4 3 109 2mm 4 3 109 2mm 4 45 113 0mm Cutout Dimensions H x W 12 00 x 15 00 12 37 x 17 4 13 70 x 16 35 14 90 x 17 75 305mm x 381mm 442 0mm x 34
20. n serviced by anyone other than Nematron The warranty set forth herein is in lieu of and exclusive of all other warranties express or implied Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 2 of 28 Chapter 1 Introduction The iPC Plus Series products are high performance color TFT embedded ultra thin industrial computers specifically designed for harsh industrial environments This series is an extension to the ePC Series with added features including DVD R W Dual hard drives and PCle PCI expansion The iPC Plus Series offers four versions with 15 XGA 1024 x 768 17 SXGA 1280 x 1024 19 SXGA 1280 x 1024 TFT Color LCD panels or no attached LCD nPC400 These high performance embedded industrial PCs offer processor options up to a state of the art Intel Cleron ib and i7 Processor and DRAM options up to 16 GB Additional options include 24 VDC power supply stainless steel front panels rackmount front panel iPC1950 and iPC1550KP units only and several solid state drive options including RAID level 1 With a multitude of I O and 2 34 length PCle PCI expansion slots included on the standard unit many automation applications are ideally suited for use with this series The Ultra Thin panel depth 4 45 also makes this series ideal for space constrained applications With Class and Il Division 2 approvals this industrial PC makes installation in Hazardous Locations applications simple Feat
21. ng standard rack mount hardware not supplied via the eight 4 each side counter bored holes in the front of the panel The front panel is intended to be mounted in a vertical height of 9 U 16 0 on the rack This unit is not NEMA sealed when mounted like the panel mount versions When selecting an enclosure remember to allow adequate space around the rear side of the computer for good air flow The unit is designed to work in environments up to 50 degrees Centigrade ambient temperature inside the enclosure Remember to account for heat dissipated from other equipment that may be installed inside the same enclosure Enclosed Unit Installation The enclosed iPC Plus products are intended to be stand alone NEMA Type 1 units These are required to be mounted to a VESA style mount with a minimum load rating of 40 pounds A desktop stand wall mount or articulating arms are examples of VESA style mounts that can be utilized These units are vented for air flow and are not dust or water proof Care should be taken to not utilize these units in areas where high concentration of particulate matter or moisture are present If these conditions do exist then the use of the panel mount versions in an appropriate NEMA 4 4x or 12 enclosure should be considered The warranty may be voided if high levels of moisture or particulate matter are determined to be the cause of a failure The iPC Plus EN units have filters on the rear to filter incoming air These fi
22. of each lead can be utilized to prevent frays if desired Optionally the included protective cover can be utilized to prevent electrical shocks when handling the power connector and provide strain relief for each conductor connection see the following section for installation instructions After the connections are made make sure the plug retention screws the two screws shown in the Front View below are securely tightened This will prevent the plug from pulling out The use of these screws is mandatory when the unit is utilized in applications requiring hazardous locations approvals 6 6 omm TOP VIEW 200 1777992 sa T E FRONT VIEW Zo 19 PIN NUMBER 100 VAC 240 VAC INPUT 18 VDC 36 VDC INPUT EE AC Line Input DC Input E AC Neutral Return DC Return E 2 FRONT VIEW Protective Earth Ground Protective Earth Ground Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 20 of 28 NOTE WHEN USING USB CONNECTIONS THE USE OF THE USB RETENTION BRACKET IS REQUIRED FOR HAZARDOUS LOCATIONS AND HIGHLY RECOMMENDED FOR NONHARDAOUS LOCATIONS NOTE TO PREVENT INADVERTENT DISCONNECTIO
23. or RS 485 See section on connector pin outs and jumpers in the CPU board manual for more detailed instructions and information on the configuration of this port HDMI A standard HDMI port is provided This connection allows a second screen to be easily added to the iPC In addition the iPC allows this second screen to be utilized in an extended desktop configuration Gigabit Ethernet Two Ethernet ports are provided that are both capable of 10 100 1000 Base T communications USB 2 0 Two ports capable of USB 1 1 and USB 2 0 are provided USB 3 0 Four ports capable of USB 1 1 USB 2 0 and USB 3 0 are provided PS 2 Port One PS 2 port is provided This port is capable of being used singularly as a mouse or keyboard port If both devices are desired to be utilized simultaneously a special Y cable cable must be utilized The keyboard or mouse must be connected to the appropriately marked cable end Input Power The Input power whether AC or DC is supplied via a Phoenix connector See Chapter 2 on Installation for more details on how to wire this connection Audio Audio Line IN Audio OUT and Microphone ports are supplied These are IN OUT MIC unamplified signals and can be used to input or output sound Document No DOC IPC 005 User Manual iPC Plus amp 400 Rev A Rel 1 2015 Page 8 of 28 DISPLAY iPC1550 amp iPC1550KP iPC1750 iPC1950 Display Diagonal 15 0 381 0mm 17 0 431 8
24. r of the front panel are reprogrammable keys than can be used for specific application key returns The System keys are can also be re legended They also have Alpha characters in the top left and right corner of each key These Alpha characters and symbols are not reprogrammable and cannot be removed by changing the legend strips The default key returns for S1 S6 are ALT SHIFT F1 F6 respectively These keys are multi functional and can return Alpha Symbols and or Function keys See the explanation of Mode and Led Keys below Cursor Control Keys The 9 keys just above the System Keys return standard PC keyboard functionality as marked on each key These keys are not able to be reprogrammed or their legend changed This keypad section is dedicated to cursor movement on the screen and or in an application Numeric and Control Keys The 26 keys just above the Cursor Control Keys return standard PC keyboard functionality as marked on each key These keys are not able to be reprogrammed or their legend changed This keypad section is dedicated to numeric and standard keyboard control keys DEL CTRL ESC ENTER etc Mode Keys and LED Indicators At the top right hand of the front panel are four keys with special functionality These keys allow the Alpha Symbols and Capital Letters to be utilized These keys are not reprogrammable and cannot be relegended See the section below for more detail on ho
25. re Document No DOC IPC 005 User Manual iPC Plus amp nPC400 RevA Rel 1 2015 Page 4 of 28 iPC1550KP Front Panel The iPC1550KP T front panel is significantly different than the other touchscreen only members of the iPC Plus series This front panel contains nearly full alpha numeric keyboard functionality while still providing the option for a touchscreen The keypad front panel is connected to the main CPU board via USB port therefor older operating systems that do not recognize USP ports cannot be utilized The keypad front panel shown below has 81 keys with many of them having multiple functionality The keypad is broken up into 6 functional sections ATM style Screen Keys Function Keys Mode and LED Indicators Numeric and Control Keys Cursor Control Keys and System keys The ATM style Screen Keys Function Keys and System Keys are reprogrammable to return different key strokes If a different key return or combination is required for these keys consult the factory for more information on this subject The Function and System Keys have rear legend strips that can be removed and new strips reinserted with custom graphics Mode Keys amp 3 LED Indicators ATM style Screen Numeric and Keys 2 x 8 Reprogrammable Control Keys Cursor Control EE KON HIE KCN EON ON System Keys rn ca ro ra ca ca ca 51 56 Alpha and Symbols not changeable Function Keys
26. stalled in an approved NEMA enclosure constructed from 14 gauge or heavier steel The computer uses U shaped clips and a special gasket to achieve the proper seal When selecting an enclosure remember to allow adequate space around the rear of the computer for good air flow Do not block air flow from below or above the monitor If possible mount the computer in a vertical orientation The unit is designed to work in environments up to 50 degrees Centigrade ambient temperature inside the enclosure Remember to account for heat dissipated from other equipment that may be installed inside the same enclosure To install the computer make a cutout according to the diagrams below in one of the walls of your NEMA enclosure Next hold the unit in place while you install the mounting clips Tighten the clips to the point were the back of the unit s front bezel just begins to contact the front of the NEMA enclosure The use of an adjustable torque driver is recommended The screws should be tightened to 8 inch pounds Tighten the clips in a cross pattern This will help to develop an even pressure on the sealing gasket DO NOT OVER TIGHTEN AS DAMAGE CAN RESULT IN THE COMPUTER CAUSING LOSS OF SEALING INTEGRITY Cutout Pattern for 1550 1550 Industrial Computer i 12 0 02 15 0 02 Document DOC IPC 005 User Manual iPC Plus amp nPC400 Rev Rel 1 2015 Page 15 of 28 Cutout Pattern for i
27. the other LED turns off 51 E3 EJ Function Key Characters Caps Lock When in Alpha Mode and the Caps Lock LED is on letters will return upper case otherwise return lower case like std keyboard Shift While holding Shift Key in Alpha mode and Caps Lock LED is off upper case letters will be returned With Caps Lock LED on and holding Shift lower case will be returned Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 7 of 28 Panel All versions of the iPC Plus series a common Input Output configuration Figure 2 0 shows the base configuration of the three units RS 232 422 485 Port Port Port Port Dual Gigabit Ethernet Ports Line In Audio Out Microphone HDMI RS 232 VGA Video Four USB 3 0 Ports Figure 2 0 iPC Plus Series I O configuration Feature Description Video Port A standard 15 pin analog VGA is provided This connection allows a second screen to be easily added to the iPC In addition the iPC allows this second screen to be utilized in an extended desktop configuration See section on configuring the video for more details on this feature Com 1 Com 1 is a standard 9 RS 232 serial port Com 2 Com 2 utilizes a standard 9 pin serial port The iPC default configuration for this port is RS 232 a BIOS selection this port can alternately be configured RS 422
28. to secure your cable end to the unit Ethernet connections have a plastic tab that prevents the connection from falling out The keyboard mouse port splitter provided is not secured and is intended for setup and maintenance only when in an area that is known to be nonhazardous See the connecting power section for details on securing the power connections In addition to the USB Bracket there is an additional cable management bracket at the bottom of the units that can be utilized to strain relief cables This is a flat bracket attached by 2 screws which can be utilized to hold down cables or provides an attachment point for a cable tie to be used for securing cables Care should be taken to provide an adequate radius for any cable being utilized Too tight a radius can damage the conductors When tightening this securing bar care should be taken not to over crush cables this can damage conductors Cable Securing Bar Installed NOTE WHEN USING USB CONNECTIONS THE USE OF THE USB RETENTION BRACKET IS REQUIRED FOR HAZARDOUS LOCATIONS AND HIGHLY RECOMMENDED FOR NONHARDAOUS LOCATIONS NOTE TO PREVENT INADVERTENT DISCONNECTION OF VIDEO AND OR SERIAL TOUCHSCREEN CABLES ASSURE THAT THE THUBSCREWS ARE SUFFICIENTLY TIGHTENED WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE OF IGNITABLE CONCENTRATIONS Document DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A
29. tor the appropriate driver will be included with the monitor Operating System Recovery If for some reason your operating system needs to be reinstalled Nematron provides an Operating System or Recovery disk The procedure for this is dependent on the operating system Because this series does not have an integrated DVD you will need a USB DVD ROM drive In some cases you will also need the Documentation and Driver disk that is included with each unit The iPC Plus series products are only shipped with Windows XP Professional SP3 Windows 7 Professional 32 bit and Windows 7 Ultimate 64 bit Use of other operating systems is not recommended and not supported Document DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 26 of 28 Windows Professional SP3 for Embedded Systems Standard Windows XP operating system disks are no longer available from Microsoft In order to continue shipping Windows XP for Automation applications Nematron had to switch to a different license scheme Windows XP Professional SP3 for Embedded Systems This is not Embedded XP it is simply a different license procedure By switching to this license Nematron had to create a system recovery disk This disk is very specific to the platform and options that are included on your unit Do not attempt to use a recovery from one type of unit on another it may not work This recovery disk installs the factory image with all drivers installed
30. ures e Processor Options up to Intel i7 Quad Core options e DRAM Options up to 16 GB e Up to two easily removable SATA solid state or hybrid hard drives e Numerous Ports Two Gigabit Ethernet ports 4 USB 2 0 and 2 USB 3 0 ports 2 RS 232 serial port 1 RS 422 485 Serial port PS 2 mouse and keyboard ports Audio In Out Mic Analog VGA or HDMI ports for dual screen applications with attached LCD installed e UL 508 and ANSI ISA 12 12 01 2012 listed for Hazardous Locations Class l Division 2 Groups A B C D and Class Il Division 2 Groups F G Class when installed in a NEMA Type 1 4 4 12 enclosure does not include the optional enclosed EN units 4 4 12 front bezel panel mount versions only Optional Vented back enclosure EN option o iPC1550 only 2 Year warranty RoHS compliant European CE mark compliant Integral 100 240 VAC power supply Simplified installation with no studs Ultra Thin design less than 4 45 behind front panel VESA compliant all modes up to SXGA 75Hz XGA on 15 unit Optional 5 wire resistive touch screen Optional 304 stainless steel front bezel Optional iPC1500KP Keypad front panel 15 only Optional iPC1950 Rack Mount front bezel 19 only not NEMA sealed Optional 24 VDC input power Windows 7 Professional 32 Bit pre installed o Windows Ultimate 64 bit optional o Windows XP Professional 32 bit optional Document
31. w these Mode keys function Document No DOC IPC 005 User Manual iPC Plus amp nPC400 Rev A Rel 1 2015 Page 6 of 28 Mode Keys and Led Indicator Functionality The four keys at the top right hand of the keypad front panel are custom designed to allow the 26 keys at the bottom of the front panel Function Keys and System Keys to have multiple functionality This multiple functionality allows these 81 keys to provide virtually every key on a standard PC keyboard The Alpha and Symbol keys allow the left and right legends at the top of the Function and Symbol keys to utilized The Alpha and Symbol Key functionality is described as follows e Alpha mode on returns Alpha characters on upper Left side of lower 26 keys Symbol mode on returns Symbol characters on upper Right side of lower 26 keys e Alpha and Symbol modes both off returns F1 F20 and 51 56 A more detailed explanation of the functionality of these four keys is explained as follows gro gro Ere ro F20 Symbol Characters Alpha Characters Alpha and Symbol are mutually exclusive Both LEDs off unit is in Function Key mode First press turns LED on and appropriate mode is selected Press same key again turns LED off and returns to Function Key mode Press the other Key and the other mode is selected that LED turns on and