1. WAVE NE User s Manual Model No VVL YL 2612B Index e Important Safe Guards e Ambient Environment For Operating e Component Diagrams e Operating Introduction e Functions of Control Panel amp Key Pads e LCD Displav e Operation of Kev Pads e Automatic Defrosting e Water Tank Full Warning e Processions Of Abnormal Compressor e Protection Of Extremely Low amp High Temperature e Failure Of Humidity amp Temperature Sensor e Memory function e Continuous Drainage e Maintenances amp Cleaning e Specification Important Safe Guards Do not install and use the unit before carefully reading this instruction guide Please retain this manual for product warrantv and future reference 1 Please be sure your electricity is fully working 3 To reduce a fire risk ensure the unit is not placed next to a high temperature appliance 5 Do not allow children to operate this unit Never disassemble the unit and never try to carry out repairs or adjust the unit yourself 7 Do not use the unit when mounted on a slant If for any reason the unit falls over pull out the plug at once 9 Make sure the inlet and outlet ventilation is not blocked at any time 2 To avoid an electric shock avoid placing the unit near window or in a bathroom 4 Do not operate this unit in an explosive or corrosive environment 6 Operate this unit on a horizontal surface to avoid vibration and noise
2. 8 When positioning ensure there is 30 cm of clear Space on each side of the unit 10 Never allow water to spray onto the unit Contact with water may cause malfunction and electric shock 12 Alwavs switch off at the socket before unplugging 11 Never pull the plug with damp hands to avoid electric shock 13 When storing the unit switch it off and unplug it S and ensure the water reservoir is emptied AR 14 Do not pull the power wire by force as it will cause damage to wire f ee Sa 15 Do not place any foreign objects into any of the openings of the unit 16 Unplug the appliance during cleaning Ambient Environment For Operating 1 Working environment Lowest ambient temperature 5 C 40 RH Highest ambient temperature 35 C 90 RH 2 Always operate the unit indoors e g living room bedroom etc Avoid using in a wet environment or outdoors 3 Before turning on the unit ensure all doors and windows are closed 4 Ensure that the unit is placed on a stable and flat floor surface If the floor surface is not even there is a risk that the unit may become unstable and topple over or excessive vibration and noise may occur Component Diagrams Air deflector Control panel Handle Air intake Drainage hose Operating Introduction e Functions of Control Panel amp Key Pads SETTING 1 POWER Switch the power button on the unit to start up 2 Pre
3. Dehumidifving Power Max Power Dissipation Dehumidifving Air Volume Refrigerant Capacitv of Water Tank Unit Dimension Specification WL YL 2612B 220 240VAC 50Hz 12L D 30 C RH80 255W 30 C RH80 300W 35 C RH90
4. has experienced extremely low amp high temperature the appliance will not keep its memorv function when restart e Failures Of Humidity amp Temperature Sensor 1 When an error between the humidity and temperature sensor occurs the symbol of dehumidification Hi will flash and 0 C O RH is displayed on the LCD display At this point the appliance adopts the continuous dehumidifying mode 1 If the temperature sensor malfunctions the appliance will adopt the continuous dehumidification mode and not a controlled humidity setting 2 This malfunction will not influence the dehumidification 2 When the temperature sensor of the evaporator is an open circuit or short circuit the symbol of defrost dE will flash and the appliance turns to dehumidifying and defrosting mode dehumidifving for 20 minutes then defrosting for 5 minutes 1 If the temperature sensor malfunctions the keys within the control panel will perform normally 2 1f the temperature sensor malfunctions the appliance will continue to work with lower efficiency Viemorv Function If the power supply is cut off when the appliance is running it will memorise its working mode automatically Once power has been restored the appliance will restart and continue in this working mode 1 The appliance will not run the memory function for manual amp timing shutdown in this instance the appliance will restart to run in its original state not recover bac
5. RH 60 RH see 1 When entered into automatic dehumidification if you press Setting the continuous dehumidifying mode will be cancelled 2 Press Mode or three seconds after pressing Setting the desired humidity ratio is set and the indicator light switches off 3 When sensor detected ambient humidity is 1 lower than your setting compressor shut off and fan works at low speed If ambient humidity is 5 higher than the setting the dehumidification is activated again 2 When the wind speed qe indicator illuminates press Setting to select your desired fan blower setting of High speed level or Low speed level 1 It shows L when working at Low speed level and shows H when working at High speed level 2 Press Mode or three seconds after pressing Setting the wind speed is set 3 When the wind speed is set dynamic patterns rotate 4 When the sensor detects that the ambient humiditv is lower than vour desired setting the fan works at low speed 5 When the sensor detects that the ambient temperature exceeds 32 C the fan works at the High speed level automatically 3 When the continuous dehumidification indicator Cd illuminates press Setting to make the unit run at the continuous dehumidification mode 4 SETTING When the indicator light illuminates according to your desired mode pressing Setting will confirm the running mode or automatic dehumidifying ra
6. k to the last set mode 2 If the power supply is shut off into a protection mode the appliance will not recover back to the last set mode e Continuous Drainage Remove water plug and connect with PVC hose with spigot A N PVC hose must be placed on the ground flatly Do not tangle the hose Do not immerse the hose outlet end into another receptacle as it may cause water flow blockage Maintenance amp Cleaning Before any maintenance or cleaning please switch off and unplug the unit Do not place in direct sunlight as the plastic casing may discolour Take care when removing the water tank Only use a soft clean cloth to clean this unit Do not use gasoline paint thinner or other chemicals to clean the unit Cleaning mesh filter Remove the filter in arrow direction as shown on figures Use a vacuum cleaner or water to clean and then put it in ventilated place until it s dry Air intake frame Always switch off and unplug before moving this unit When packing away this unit for a long period of time switch off and unplug the unit empty the water tank and leave to dry for two days Then store it in a dry ventilated place If you have any problems with your appliance please approach your dealer We cannot be held responsible for any damage or injury caused by unauthorized action If this unit becomes defective please dispose of it responsibly Model Power Rated Moisture removal
7. laved on LCD screen Note all other svmbols turn to orange and the appliance cuts out At this point the water tank must be removed emptied and reinstalled before the unit can operate again The interval of dehumidifving lasts about 3 minutes because of the compressor protection Remove Water Reservoir as Arrow Direction e Abnormal Compressor Warning During operation any malfunction can trip the compressor to fail resulting in a compressor shut off It takes 3 minutes to recover from the protection period A After the water reservoir is removed it takes about 3 minutes to start up the unit again for protection purposes To avoid this protection period simplv remove the plug from power socket to restart the unit e Protection Of Extremely Low amp High Temperature 1 When the sensor on the air intake detects ambient temperature lt 0 C or 240 C the appliance will shut off automaticallv for protection and the warning beeps will continue with 3 long and 2 short signals When the sensor detects ambient temperatures s02C 0 C is showed on the LCD display When the sensor detects ambient temperatures 240 C 40 C is showed on the LCD display 2 When sensor on the evaporator detects its temperature 240 C the appliance will shut off automatically for protection and the symbol for automatic defrost dE illuminates A 1 If all function keys are not working you should switch off at the mains to restart the unit 2 After the unit
8. ss mode to select the desired working mode and the corresponding indicator light will illuminate 3 Press Setting to select the desired running mode and ambient humidity 4 TIMER Reserve amp Turn Off hour settings e LCD Monitor RH Wind Setting opeed Automatic dehumidifying Continuous Dehumi diving Ambient i Water full Temperature L i a Ambient i ha f Humidity Defrost Timer Dehumidifying e Operation Of Kev Pads 1 The unit will beep twice once plugged into the power socket 2 Press the ON OFF button to turn on the unit The deflector will startup automatically and at this point the unit is in the status of constant dehumidifving and high speed running 1 The blue backlight will illuminate and turn off after 15 second 2 The LOD displav shows the working mode and status of unit 3 The LOD displav shows the ambient humiditv and temperature 4 Press the ON OFF button again the unit will stop working and the deflector close 3 MODE Set up continuous amp automatic dehumidifying modes and air speed by using the MODE key Select or change to the desired mode the indicator light will illuminate accordingly then press Setting to change the running mode and automatic dehumidifying ratio 1 When the automatic dehumidification indicator afl illuminates press Setting to make it circulate among 60 RH 65 RH 70 RH 75 RH 80 RH 40 RH 45 RH 50 RH 55
9. tio 5 Press TIMER Press TIMER to set the working hours of the unit Time set for switching on When the appliance is powered off or in standbv mode press Timer 1 to 24H or flexible working time to set up a required operating time When the unit reaches the requested time the unit switches on and starts to work automaticallv Time set for shutdown When the appliance is powered on press Timer 1 to 24H or flexible working time to set the unit s running hours Once the time is set the remaining hours are shown on the screen until time is up 3 Please note The memorv function will not work when the timer is set for shutdown e Automatic Defrosting A working cycle When the appliance works in low temperatures frost may appear on the surface of the evaporator To ensure the unit performs well in these conditions an automatic defrost function is fitted to the appliance 1 When a room temperature drops down to 16 C or less the compressor works for 25 minutes dehumidifving then cuts off The fan blower then keeps running for 7 minutes to defrost in 2 When defrost Symbol of defrost displayed on LCD and the symbol of ee dehumidification lej goes out 3 When defrost Symbol of defrost displayea on LCD the compressor is shut off fan runs at high speed e Water Tank Full Warning When the water tank is full a buzzer will alarm 10 times for about 5 seconds and the symbol i that indicates a full tank is disp

Download Pdf Manuals

image

Related Search

Related Contents

Graco 406719B User's Manual  Andis Company Ceramic Styler 1875 User's Manual  844KB  care and maintenance remote functions (for cd operation only)  User Manual Climate Controller KR494 Version  E5071C ENA Series RF Network Analyzers  VIEW™ DV C - Touchboards  pedale harmonique MODE D EMPLOI  wt3116 – marcador/cronómetro deportivo  Istruzioni per l'uso  