Home

BP7408-3 CURVA CF244 CF252

image

Contents

1. ODO My U L Model 244 amp CF252 14 EMERSON Repair Parts Listing Damp Part Numbers Wet Part Numbers Key Model No Model No Model No Model No Model No Model No Model No Model No No Description CF244BS00 CF252BS00 CF244CRMO0 CF252CRMOO CF244wwo00 CF252WWO00 24408 00 25208 00 Hanger Pack Consisting of 761655 17 761655 17 761655 88 761655 88 761655 14 761655 14 761655 32 761655 32 1 Hanger Bracket Assembly 2 Hanger Ball 3 Downrod 4 Ceiling Cover 762534 BS 762534 BS 762534 CRM 762534 CRM 762534 WW 762534 WW 762534 ORB 762534 ORB 5 Coupler Cover 764000 BS 764000 BS 764000 CRM 764000 CRM 764000 WW 764000 WW 764000 ORB 764000 ORB 6 Lower Housing 763992 BS 763992 BS 763992 CRM 763992 CRM 763992 WW 763992 WW 763992 ORB 763992 ORB 7 Light Kit Plate Assembly 763993 763993 763993 763993 763993 763993 763993 763993 8 Glass Shade 763994 0 763994 0M 763994 0 763994 0 763994 0 763994 OM 763994 0 763994 0 9 No Light Kit Cover 763995 BS 763995 BS 763995 CRM 763995 CRM 763995 WW 763995 WW 763995 ORB 763995 ORB 10 52 Blade Assembly 763996 5 763996 BS 763996 WW 763996 ORB 11 44 Blade Assembly 763998 BS 763998 BS 763998 WW 763998 ORB 12 Harness Wiring Reverse Modular amp Aux Capacitor 764007 764007 764007 764007 764007 764
2. EMERSON 16 U L Model No CF244 amp CF252 17 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF244 amp CF252 gt EMERSON 18 U L Model No CF244 amp CF252 Emerson Air Comfort Ceiling Fan Limited Warranty What The Limited Warranty Covers This limited warranty is offered by Air Comfort Products division of Emerson Electric Co Emerson we or located at the address stated below to the original retail purchaser you or your of an Emerson Air Comfort Ceiling Fan product Emerson Ceiling Fan and covers the motor and the other components and accessories of the Emerson Ceiling Fan against all defects in workmanship and materials What The Period Of Coverage Is This limited warranty will cover the Emerson Ceiling Fan motor for the expected lifetime of your Emerson Ceiling Fan when operated in accordance with your Owner s Manual or other instructions provided by Emerson to you with the Emerson Ceiling Fan All other components and accessories of the Emerson Ceiling Fan are covered by this limited warranty for a period of one 1 year from its date of original retail purchase ANY IMPLIED WARRANTY INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS AVAILABLE TO YOU UNDER THE LAWS OF YOUR STATE OR PROVINCE SHALL COVER THE MOTOR FOR THE EXPECTED LIFETIME OF THE MOTOR SUBJECT TO PROPER USE AND FOR ONE YE
3. refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Electrical Requirements IMPORTANT Your ceiling fan will not function properly and may be damaged if used with any wall dimmer switch or control other than the Emerson Electric Fan Light Remote Control supplied with the fan Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds 44 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Ph EMERSON If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture 44 WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be pr
4. Hang Your Ceiling Fan WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 9 WARNING The outlet box and joist must be securely mounted and capable of supporting at least 50 Ibs Use only a outlet box listed as Acceptable for Fan Support of 22 7 kg 50 Ibs or less 44 WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling fan mounting plate on the outlet box WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock 2 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 10 3 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the
5. future use gt EMERSON U L Model No CF244 amp CF252 Unpacking Instructions 4 WARNING PACKAGE CONTENTS Do not install or use fan if any part is damaged or Description Quantity missing Call Toll Free Fan Motor Assembly Ceiling Cover Coupler Cover Fan Blades Lower Housing Light Kit Plate Glass Shade No Light Cover Plate Hanger Bracket Hanger Ball Downrod Assembly 6 Speed Electronic Receiver Control with Parts Bag ae 6 Speed Handheld Transmitter 1 Open carton containing fan Remove top half of with Wall Bracket styrofoam unit Remove parts and check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding HARDWARE CONTENTS Description Quantity Wire Connectors 12 ga M5 x 16mm Flange Head Blade Screws M4 x 10mm Pan Head Screw for Lower Housing Light Kit spare Clevis Pin Hairpin Clip Threaded Stud 8 32 x 1 1 4 External Tooth Lockwasher Knurled Knob Blade Balance Kit gt gt ae 1 800 654 3545 WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by E
6. keep it for future reference 2 Be careful of the fan and blades when cleaning painting or working near the fan Always turn off the power to the ceiling fan before servicing 3 Do not put anything into the fan blades while they are turning 4 Do not operate reversing switch until fan blades have come to a complete stop Additional Safety Instructions for Installation 1 To avoid possible shock be sure electricity is turned off at the fuse box before wiring and do not operate fan without blades 2 All wiring must be in accordance with the National Electrical Code ANSI NFPA 70 2011 and Local Electrical Codes Use the National Electrical Code if Local Codes do not exist The ceiling fan must be grounded as a precaution against possible electrical shock Electrical installation should be made or approved by a licensed electrician Safety Instructions 3 The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds Use only U L outlet boxes listed as Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan
7. must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch NOTE This fan is suitable for use with solid state speed controls WARNING To reduce the risk of fire or electric shock this fan should only be used with fan speed control Model No UC8013R manufactured by Rhine Electric Co Ltd WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades NOTE All setscrews must be checked and re tightened where necessary before installation DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for
8. outlet box Figure 11 Be sure the groove in the ball is lined up with the tab on the hanger bracket Figure 10 4 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall 4 WARNING Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard CEILING 4 TWO SCREWS SUPPLIED WITH OUTLET BOX Figure 10 NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY HANGER BRACKET HANGER BALL DOWNROD ASSEMBLY Figure 11 A WARNING To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF244 amp CF252 How to Wire Your Ceiling Fan If you feel that you do not have enough electrical wiring knowledge or experience have your fan installed by a licensed electrician A WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock CAUTION To reduce the risk of electrical shock disc
9. 007 764007 764007 13 Handheld Remote Control 763979 763979 763979 763979 763979 763979 763979 763979 14 Electronic Receiver with Wire Connectors 764009 764009 764009 764009 764009 764009 764009 764009 Parts Bag Containing 764025 55 764025 SS 764025 SS 764025 SS 764025 SS 764025 SS 764025 SS 764025 SS 15 Connector Wire 12 Ga 3 16 Screw Flange Head Blade 5 x 16mm 10 17 Screw Pan Head Lower Housing Light Kit M4 x 10mm 1 18 Pin Clevis 19 Clip Hairpin 20 Stud Threaded 8 32 x 1 1 4 2 21 Lockwasher External Tooth 8 32 x 1 1 4 2 22 Knob Knurled 8 32 2 23 Kit Balancing 24 190 W Circuit Breaker 763748 763748 763748 763748 763748 763748 763748 763748 BP7408 3 BP7408 3 BP7408 3 BP7408 3 BP7408 3 BP7408 3 BP7408 3 BP7408 3 Owner s Manual Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION e PART NUMBER NAME OF ITEM e PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 emersonfans com Please contact 1 800 654 3545 for further assistance 15 U L Model No CF244 amp CF252 Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and produ
10. AR WITH RESPECT TO COMPONENTS AND ACCESSORIES No Other Express or Implied Warranty Applies THE LIMITED WARRANTIES PROVIDED ABOVE ARE THE SOLE AND EXCLUSIVE WARRANTIES PROVIDED BY EMERSON TO YOU FOR YOUR EMERSON CEILING FAN AND ARE IN LIEU OF ALL OTHER WARRANTIES WRITTEN OR ORAL EXPRESS OR IMPLIED WHETHER ARISING BY OPERATION OF LAW OR OTHERWISE WHETHER OR NOT THE PURPOSE HAS BEEN DISCLOSED AND WHETHER OR NOT THE EMERSON CEILING FAN HAS BEEN SPECIFICALLY DESIGNED OR MANUFACTURED FOR YOUR USE OR PURPOSE EMERSON HEREBY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR COMPONENTS AND ACCESSORIES AS OF THE EXPIRATION OF THE ONE YEAR WARRANTY PERIOD FOR SUCH COMPONENTS AND ACCESSORIES IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE FOR THE MOTOR PORTION OF THE EMERSON CEILING FAN ARE LIKEWISE DISCLAIMED BY EMERSON AT SUCH TIME THAT THE EXPECTED LIFETIME OF THE EMERSON CEILING FAN UNDER NORMAL USAGE HAS BEEN REACHED EXCLUSIONS OR LIMITATIONS OF IMPLIED WARRANTIES MAY VARY FROM STATE TO STATE AND PROVINCE TO PROVINCE SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU What We Will Do To Correct Problems If during the one 1 year warranty period the motor or any component or accessory of your Emerson Ceiling Fan is defective in materials or workmanship or if during the expected lifetime of the Emerson Ceiling Fan when used in accordance w
11. READ AND SAVE THESE INSTRUCTIONS EMERSON CURVA 44 amp 52 Damp amp Wet Location Snugger Ceiling Fan Owner s Manual 44 Model Numbers for Damp Locations CF244BS00 Brushed Steel CF244CRMOO Chrome 44 Model Numbers for Wet Locations CF244wWwo0o Appliance White CF2440RB00 Oil Rubbed Bronze Net Weight 18 3 Lbs 52 Model Numbers for Damp Locations CF252BS00 Brushed Steel CF252CRMOO Chrome 52 Model Numbers for Wet Locations CF252WW00 Appliance White CF2520RB00 Oil Rubbed Bronze Net Weight 19 2 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday Part F40BP74080003 Revision 130211 www emersonfans com Form No BP7408 3 U L Model No CF244 amp CF252 READ AND SAVE THESE INSTRUCTIONS A WARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in a manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a warning device such as a tag to the service panel 1 Read your owner s manual carefully and
12. ase contact 1 800 654 3545 for further assistance U L Model No CF244 amp CF252 Ceiling Fan Assembly continued 11 Carefully turn the partially assembled ceiling fan right side up and place the fan securely into the packing styrofoam in preparation for final assembly HANGER BALL 12 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 5 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 16 SETSCREW DOWNROD 13 Loosen setscrew in motor coupler if necessary Separate untwist and unkink the three 80 motor leads Route the motor lead wires through the downrod Align the clevis pin holes in the downrod with the holes in the motor coupler Install the clevis pin and secure with the hairpin clip Figure 6 The clevis pin must go through the holes in the motor coupler and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis from working loose Pull the downrod to make sure the clevis pin is properly installed Figure 5 DOWNROD SETSCREW 2 CLEVIS PIN i 51 MOTOR COUPLING A WARNING It is critical that the clevis pin in the motor co
13. at areas on the top flange of the cover plate with the three pins on the inside of the fan motor housing assembly Figure 17 Then turn the cover plate clockwise until it stops turning 2 Your cover plate is now installed FLAT AREA 3 DIMPLES 3 Figure 17 Remote Control Procedures General Installation of Battery Your Emerson Ceiling Fan Light Remote Control 1 Remove the battery cover by pressing firmly below consists of hand held transmitter and a receiver which the arrow and sliding the cover off the control is mounted under the fan ceiling cover The remote Figure 18 control is designed to separately control your ceiling fan 2 Install two AAA alkaline batteries and reinstall the The remote control transmitter is powered by two AAA alkaline batteries included To prevent possible damage if the batteries should leak be sure to remove the batteries when the control is not to be used for an extended period of time Code switches in the transmitter and receiver may be set in 32 different positions If your fan and light go on Betts SO and off without using your control you may be getting interference from other remote units such as garage door openers car alarms or security systems To remedy this situations simply change the combination REMOTE CONTROL LEVERS code in your transmitter and receiver CODE SWITCHES BATTERY REMOTE CONTROL Preset Memory Feature igu Your Emerson
14. could damage the motor or the blades and create the possibility of an electrical shock Accessories 1 Downrod Extension Kits see store or catalog 2 Ceiling Fan Controls see store or catalog A WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury A WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 Ibs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt Remote Control Trouble Shooting Fan Light Fails to Operate Check that the speed switch on the fan is set to HIGH speed Check that the light switch is Check that the battery is good red indicator light should light when any button is pressed Check that the receiver is wired properly Check that code switches the remote control and receiver are set in the same position Short Range Ifthe remote control operates the fan when close to it but does not operate it at a distance of 40 feet try placing the antenna wire outside of the ceiling cover Light Kit Circuit Breaker In accordance with Federal Law this ceiling fan is equipped with a light kit circuit breaker Using hal
15. ct performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult your Emerson Retailer for optional Using the Ceiling Fan Year Round In the summer use the ceiling fan in the counter clockwise direction The airflow produced by the ceiling fan creates a wind chill effect making you feel cooler Select a fan speed that provides a comfortable breeze lower speeds consume less energy In the winter reverse the motor and operate the ceiling fan at low speed in the clockwise direction This produces a gentle updraft which forces warm air near the ceiling down into the occupied space Remember to adjust your thermostat when using your ceiling fan additional energy and mounting accessories dollar savings could be realized with this simple step Turn Off When Not in the Room Ceiling fans cool people not rooms If the room is unoccupied turn off the ceiling fan to save energy INSTRUCTION TO THE USER if device contains a digital device This equipment has been tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generat
16. des are in place Noise and fan damage could result A gt EMERSON HANGER BRACKET HANGER BRACKET ROUND WIRE ROUND WIRE GREEN SUPPLY GROUND WIRE GREEN OR BARE RECEIVER WHITE SUPPLY WIRE CEILING COVER Figure 12 RECEIVER OUTLET BOX BLACK SUPPLY WIRE BLACK FAN WIRE BLACK WHITE RECEIVER WIRE RECEIVER WIRE WHITE RECEIVER WIRE WHITE FAN WIRE WIRE CONNECTOR BLACK SUPPLY WIRE WHITE A RECEIVER WIRE BLACK RECEIVER WIRE BLACK WHITE RECEIVER WIRE WHITE FAN WIRE gt BLACK FAN WIRE Figure 13 BLUE RECEIVER WIRE BLUE FAN WIRE U L Model No CF244 amp CF252 How to Wire Your Ceiling Fan continued 3 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other inside of the outlet box 4 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 11 5 Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover Figure 14 Secure the ceiling cover in place by sliding lockwashers supplied over the threaded studs and installing the two knurled knobs supplied Figure 14 Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling WARNING T
17. el numbers shown on your Emerson Ceiling Fan Once we have processed your return authorization request we will provide you with a postage paid return label which should be affixed to the Emerson Ceiling Fan package you ship to the address listed at the end of this limited warranty The return label will be sent to the mailing address you provide to us by phone What Is Not Covered This limited warranty does not extend to and expressly excludes The glass globes and light bulbs of your Emerson Ceiling Fan e Loss or damage to the motor or any component or accessory caused by normal wear and tear rather than due to defects in materials or workmanship e Loss or damage resulting from conditions beyond our reasonable control including without limitation repairs not made at our factory or authorized service center use of parts or accessories not provided to you as part of this warranty by our factory or authorized service center mishandling unreasonable use misuse abuse modifications or other damage caused by you or a third party to your Emerson Ceiling Fan while not in our possession e Loss or damage resulting from improper installation or other failure to comply with instructions in your Owner s Manual This limited warranty is deemed null and void upon the occurrence of either of the following events e You cease to own the Emerson Ceiling Fan product or The Emerson Ceiling Fan is moved from its original point of installation This l
18. es uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer an experienced radio TV technician for help This equipment has been certified to comply with the limits for a class B computing device pursuant to FCC Rules In order to maintain compliance with FCC regulations shielded cables must be used with this equipment Operation with non approved equipment or unshielded cables is likely to result in interference to radio and TV reception The user is cautioned that changes and modifications made to the equipment without the approval of manufacturer could void the user s authority to operate this equipment This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations A
19. imited warranty is only valid within the 50 United States the District of Columbia and Canada No other written or oral warranties apply and no employee agent dealer or other person is authorized to give any warranties on behalf of Air Comfort Products or Emerson Electric Co REPAIR REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE TO YOU UNDER THIS LIMITED WARRANTY TO THE EXTENT PERMITTED BY LAW IN NO EVENT SHALL EMERSON OR ANY EMERSON AUTHORIZED DEALER BE LIABLE FOR ANY INCIDENTAL SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING ANY ECONOMIC LOSS WHETHER RESULTING FROM NONPERFORMANCE USE MISUSE OR INABILITY TO USE THE EMERSON CEILING FAN OR FOR THE NEGLIGENCE OF EMERSON OR AN EMERSON AUTHORIZED DEALER EMERSON SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE AND IN NO EVENT REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION WHETHER BASED IN CONTRACT INFRINGEMENT NEGLIGENCE STRICT LIABILITY OTHER TORT OR OTHERWISE SHALL EMERSON S OR ANY EMERSON AUTHORIZED AGENT S LIABILITY TO YOU OR ANY INDIVIDUAL USING THE EMERSON CEILING FAN EXCEED THE PRICE PAID BY THE ORIGINAL OWNER FOR THE EMERSON CEILING FAN The term consequential damages shall include but not be limited to loss of anticipated profits business interruption loss of use or revenue cost of capital or loss or damage to property or equipment How State and Provincial Law Relates To The Warranty Some states and provinces do not allow the exclusio
20. immediately installing the light kit Power should be turned off prior to connector removal and light kit installation 7 Connect the white wire from the ceiling fan to the white wire of the light kit plate Figure 3 Connect the blue wire from the ceiling fan to the black wire of the light kit plate Use wire connectors previously removed to make connections 8 Remove one of the three screws in the lower housing and loosen the remaining two screws Figure 3 9 Tuck the wires and connectors into the fan housing Position the light kit plate into the fan housing by placing the cut out notches over the fan housing dimples Figure 4 NOTE Make sure all wires and connectors are tucked under the light kit plate and not pinched between light kit plate and fan housing 10 Attach the light kit plate assembly to the lower housing using two key slot holes Figure 4 Secure the light kit plate assembly by tightening the two screws Reinstall the screw that was previously removed FAN HOUSING M5 x 16mm FLANGE HEAD BLADE SCREWS 3 per blade SLIDE FAN BLADE INTO BLADE CENTER SLOT FAN BLADE 507 5 FAN BLADE Figure 1 REMOVE 4 x 10mm PAN HEAD LOWER HOUSING Figure 2 LIGHT KIT BLACK WIRE LIGHT KIT WHITE WIRE REMOVE ONE FAN MOTOR WHITE WIRE LOWER HOUSING KEY HOLE SLOT 2 REMOVE M4 x 10mm PAN HEAD SCREW DIMPLES Figure 4 emersonfans com Ple
21. ith the User Manual or other instructions the motor is defective in materials or workmanship you must contact Emerson during the applicable warranty period If the defect is covered by warranty Emerson will repair or replace the defective motor component or other accessory at no charge to you If repair of the motor component or accessory is not practical or possible within a reasonable time and no replacement Emerson Ceiling Fan can be provided Emerson will refund to you the actual purchase price of your Emerson Ceiling Fan We will ship the repaired or the replacement Emerson Ceiling Fan to you at no charge but you are responsible for all costs of removal and reinstallation of your Emerson Ceiling Fan How You Can Receive Warranty Service You must be the original retail purchaser and have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Service prior to your call please be prepared to provide all mod
22. ly is loose Screws securing fan blades to motor are loose Fan blades are not seated properly Hanger bracket and or ceiling outlet box is not securely fastened Fan blades out of balance Loose electrical connectors Remote control battery is weak The lamps are burnt out Lamps turn on and then turn off 13 Raise coupling cover and tighten setscrews securely Tighten the setscrew in the hanger ball downrod assembly Check to be sure screws which attach the fan blade to the motor are tight Check to be sure that the screws securing the fan blades seat firmly Tighten the hanger bracket screws to the outlet box and or secure outlet box Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation Or use supplied balancing kit to balance blades Shut off the branch circuit electricity at the fuse box or breaker panel and check the receiver electrical connectors for proper installation Replace the AAA remote batteries Turn the electricity off and replace the lamps with new 50W max lamps The built in circuit breaker is tripping check that the lamps are each 50W maximum CAUTION Turn the lights off before touching halogen lamps they are very hot and can burn your fingers emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF244 amp CF252 Repair Parts
23. merson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage co a A S TIo mn ml oj 50 Watt Halogen Mini Candelabra Bulbs 2 Remove the fan motor 7 PROTECTIVE assembly from the PLASTIC BAG protective plastic bag Place all carton contents on a protective surface emersonfans com Please contact 1 800 654 3545 for further assistance 3 U L Model No CF244 amp CF252 THE FAN MODELS CF244BS CF244CRM CF252BS amp CF252CRM ARE SUITABLE FOR DAMP LOCATIONS SUCH AS COVERED PORCHES COVERED PATIOS AND COVERED DECKS ANYWHERE THERE IS A ROOF OVERHEAD THE FAN MODELS CF244WW CF2440RB CF252WW amp CF2520RB ARE SUITABLE FOR WET LOCATIONS SUCH AS PORCHES PATIOS AND DECKS This Manual Is Designed to Make it as Easy as Possible for You to Assemble Install Operate and Maintain Your Ceiling Fan Tools Needed for Assembly One Phillips head screwdriver One stepladder One wire stripper Materials Wiring outlet box and box connectors must be of type required by the local code The minimum wire would be a 3 conductor 2 wire with ground of following size Installed Wire Length Wire Size A W G Up to 50 ft 14 50 100 ft 12 WARNING Before assembling your ceiling fan
24. n or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state or province to province emersonfans com Please contact 1 800 654 3545 for further assistance 19 U L Model No CF244 amp CF252 amp EMERSON Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Part No F40BP74080003 Printed in China Form No BP7408 3 Revision 130211 02 13 U L Model No CF244 amp CF252
25. o avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling 1 1 4 THREADED STUD 2 8 EXTERNAL TOOTH LOCKWASHER 2 CEILING COVER 8 32 KNURLED KNOB 2 Figure 14 How to Assemble Your Light Kit Glass Shade 1 Screw in two 50 watt maximum halogen mini candelabra base bulbs in the light kit plate sockets Figure 15 2 Place the glass shade into the opening in the fan motor housing assembly aligning the three flat areas on the top edge of the glass with the three raised dimples on the fan motor housing assembly and turn the glass shade clockwise until it stops Figure 16 NOTE periodically check that the glass shade is seated fully clockwise in the fan motor housing assembly SOCKETS 2 50 WATT Figure 15 MINI CANDELABRA BASE BULBS 2 FLAT AREA 3 DIMPLES 3 Figure 16 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF244 amp CF252 to Assemble Your No Light Cover Plate A WARNING Do not install any light bulbs into the light kit plate if DO NOT INSTALL LIGHT BULBS WHEN USING THE COVER PLATE using the cover plate Installation of light bulbs when using the cover plate could result in fire shock and serious personal injury 1 Place the cover plate onto the lower housing aligning the three fl
26. ogen light bulbs with greater than 50 watts rating will cause the breaker to activate If this occurs shut off the EMERSON electricity to the ceiling fan and check that the lamps are each 50W maximum The light kit circuit breaker will automatically reset when the electricity is turned off and then back on U L Model No CF244 amp CF252 Trouble Shooting WARNING FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN TROUBLE 1 Fan will not start 2 Fan sounds noisy PROBABLE CAUSE 1 Fuse or circuit breaker blown 2 Loose power line connections to the fan Fan Light Remote Control is OFF Blades not attached to fan Screws securing fan blades to motor are loose Loose screws in motor housing SUGGESTED REMEDY 1 Check main and branch circuit fuses or circuit breakers A WARNING Make sure main power is turned off 2 Check line power connections to fan 3 Turn ON Fan Light Remote Control 1 Attach blades to fan before operating 2 Check to make sure the screws which attach the blades to the motor are tight A WARNING Make sure main power is turned off Check to make sure all screws in motor housing are snug not over tight 3 Fan wobbles excessively 4 Both lamps will not illuminate Setscrews in motor coupling are not tightened securely Setscrew in the hanger ball downrod assemb
27. onnect the electrical supply circuit before installing the fan light kit or receiver NOTE Make all wiring connections using wire connectors supplied Make sure that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire 1 Position the receiver into the ceiling cover as shown in Figure 12 Place the antenna wire on top of the receiver 2 Refer to Figures 12 and 13 to connect the receiver wires to the supply wires and the fan motor wires using the wire connectors supplied with the fan as follows a Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied Figure 12 b Securely connect the supply white neutral wire to the receiver white AC IN MOTOR N wire and white neutral fan wire c Securely connect the supply black wire to the receiver black white AC IN L wire d Securely connect the fan motor black wire to the receiver black TO MOTOR L wire e Securely connect the fan motor blue wire to the receiver blue FOR BOTTOM LIGHT wire A WARNING Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until bla
28. operly grounded as a precaution against possible electrical shock A WARNING To avoid fire or shock follow all wiring instructions carefully Any electrical work not described in these instructions should be done or approved by a licensed electrician U L Model No CF244 amp CF252 Ceiling Fan Assembly General Your Emerson ceiling fan comes supplied with a Fan Light Remote Control which consists of a receiver mounted inside the ceiling cover of the fan motor housing This system allows you to regulate your ceiling fan speed and light intensity 1 Position the fan motor assembly upside down in preparation for mounting the three fan blades 2 Slide blade through blade slot in fan housing assembly Mount blade to fan housing using three M5 x 16mm flange head blade screws Figure 1 NOTE Take care not to scratch fan housing assembly when installing blades 3 Complete the remaining two blades installation per the above instructions 4 Remove one of the three screws in the motor housing assembly and loosen the remaining two screws Figure 2 5 Attach the lower housing assembly to the fan motor using the two key slot holes Figure 2 Secure the lower housing assembly by tightening the two screws Reinstall the screw that was previously removed 6 Remove and retain the wire connectors from the white and blue wires WARNING To avoid possible fire or shock the connectors should not be removed unless
29. receiver is equipped with a preset memory feature If the AC supply to the receiver is powered through a wall switch when the switch is turned OFF the control will remember the light intensity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF gt EMERSON 10 U L Model No CF244 amp CF252 Remote Control Procedures continued Installation of Storage Bracket for Remote Control A storage bracket is provided for holding your remote control when not in use If you desire to use the bracket install it on a wall that is away from excess heat or humidity Figure 19 TO INSTALL BRACKET TO WALL SLIDE THE COVER UP TO EXPOSE THE SCREW HOLES FOR INSTALLATION COVER WALL BRACKET SCREW HOLES 2 Figure 19 Setting Operating Frequency of Remote Control Your remote control has code switches which must be set in one of 32 possible code combinations Figure 18 The five levers numbered 1 2 3 4 and 5 on the switches are factory set in the ON up position Change the switch settings as follows Figure 20 1 Slide the five switch levers in the remote control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 When power is restored push and hold the fan OFF button for 3 to 5 second
30. s to set the code in the receiver 3 If airflow is desired in the opposite direction press the button on the remote control The fan must be operating at any speed for the reverse button to function The blades will turn in the opposite direction and reverse the airflow 4 To set the desired fan speed press the button to decrease the speed and to increase the speed The LED display will light up to indicate the new speed selected 5 To turn the downlight on press and release the button The light will turn on at the light intensity previously selected 6 To vary the intensity of the light hold the button down until the desired light intensity is reached then release the button 7 The sixth switch marked ON and is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to for no dimming of the lights such as for fluorescent bulbs Figure 20 emersonfans com Please contact 1 800 654 3545 for further assistance 11 U L Model No CF244 amp CF252 Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 44 WARNING Do not use water when cleaning your ceiling fan It
31. upler is properly installed and the setscrew securely tightened Figure 6 Failure to verify that the pin and setscrew are properly installed as shown in Figure 6 could result in the fan falling 14 While pulling up on the downrod securely tighten the two setscrews in the motor coupling Figure 7 NOTE The setscrews must be properly installed as described above or fan wobble could result 15 Make sure the grommet is properly installed in the coupling cover then slide the coupler cover on the downrod until it rests on the motor housing Place the ceiling cover over the downrod Be sure both the ceiling cover and the coupler cover are oriented correctly Figure 7 16 Reinstall the hanger ball Figure 8 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble Figure 7 17 The fan comes with blue black and white leads that SO N CEILING are 80 long Before installing fan measure up 007 3 COVER approximately 6 to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads Figure 8 My gt EMERSON 6 U L Model No CF244 amp CF252 How to

Download Pdf Manuals

image

Related Search

Related Contents

KEYSTONE - Pentair Valves & Controls  Ficha VL800 K4.FH11    Quantum 600 Series - Pride Mobility Products  here - PDAdb.net  PC COM 8 PORT v RS-232/RS  User's Manual    Télécharger fiche de catalogue    

Copyright © All rights reserved.
Failed to retrieve file