R&S UPX Sequencing User Manual
Contents
1. Main Window Product Identification Report number e Brand name EE NUT TT RN DEER REES EES RE eee E IC information Materials Received Schematic diagrams Block diagrams n Performance data complete a II In addition to navigation via the toolbar the preview can also be controlled using a con nected keyboard zer mm Selecting Test Sequences 2 Manual Operation 2 1 Operation of the sequencing software always involves three basic steps 1 Selection creation of a suitable test sequence and definition of properties such as name of the object manufacturer operator 2 Marking of the desired test cases which are to be processed one after the other in the list of test cases The R amp S Audio Measurements Package allows the configura tion of user defined measurements test plans 3 Processing of the test cases and if necessary checking of the results in the pre view Processing of the selected test cases can be stopped at any time and then continued later e g on the following day When closed the sequencing software automatically stores the results and states of the test cases that have so far been processed When the software is started again and Start testing is then pressed see chapter 2 2 2 Starting Marked Test Cases on page 16 the software automatically continues with the first test case that has not yet been fully processed Selecting Test Sequences
2. If several test cases are performed one after the other on a DUT all of these test results together form a test sequence Each different DUT has at least one test sequence If required however several test sequences with different properties of the DUT can be created At the beginning of each series of tests a new test sequence is generated via the menu or in the toolbar Alternatively an existing test sequence can be selected again if for example not all test cases have yet been processed In both cases a dialog box then opens in which details concerning the test sequence must be entered This information is displayed in the list of existing test sequences in order to make selection easier 2 2 2 2 1 Processing Test Cases a Please enter test sequence information Device Tested UPPS800 Serial Number 100145 Manufacturer Rohde amp Schwarz Testing Date 2015 03 21 Operator Illich Reporting Version 01 00 comments preliminary testing Information concerning the DUT the manufacturer the operator and a defined date e g the order date of a customer are specified here Processing Test Cases After a new test sequence has been created all that remains is to start the test sequence by clicking the Start testing button in the toolbar All marked test cases are now processed until either all have been processed or processing is stopped guration F During processing
3. The action editor is opened by right clicking the User Defined Measurements node and selecting the item Configure Test Cases Saf Enter Product Identification User Defined Measure Select Test Cases ER show pi ide Deselect Test Cases ROHDE amp SCHWARZ Configure Test Cases Default Selection Project Identification Deentp h Titla The tree view on the left hand side shows the action items defined for the current test sequence Action Editor 82 user defined sequence items DUPW User UPxSequencing DatalTestplanswery_easy_examplerssqtp 000000 O ee setup Based Measurement 2 d upvuserupssequencingsdataSetups 6 44 Freq Response set add item name as report header display measurement results show Sweep Graph Setup Freg Response Measurement show Impulse Response E show FFT Graph show PESE PULGUA Graph show Bargraphi O add PASS FAIL criteria show Waveform template for new sequences E Cancel OK The individual user defined steps are configured and changed in this dialog box The dialog box is divided into the following areas 1 Action window management of test plan and its action items This area contains the buttons used for management of the test plan and the indi vidual action items that are listed underneath Create new test plan Load test plan from file the test plan can then immediately be use
4. Baud Rate 115200 mani En Data Bits 8 Stop Bits 1 Parity None Handshake None The parameters for communications with an external device via the serial interface are set here COM Settings Used to set the physical properties of the interface Which COM port is to be used and how the transmission parameters are to be set These settings must exactly match those expected by the external device Device Control Used to set the maximum times for transmitting and receiving before the sequencer aborts a remote action with an error If the external device sends its responses with out CR LF at the end the set time for receiving further characters is waited out After the set time has elapsed the characters so far received are interpreted as the response Package Settings 3 6 2 Settings for LAN Interface The parameters for communications with an external device via the LAN interface are set here Host settings Used to specify the computer name or IP address of the external device to be con trolled as well as its TCP IP port number These settings must exactly match those expected by the external device Device Control Used to set the maximum times for transmitting and receiving before the sequencer aborts a remote action with an error If the external device sends its responses with out CR LF at the end the set time for receiving further characters is waited out After the set time has elapsed the characters so far received
5. Stopping and Interrupting Pro cessing on page 18 AUN OK The icons mean start processing of the test cases stop processing pause continue processing On the right is an indicator showing the current status of the sequencer The following states are indicated tor Icons for preview These icons control the preview function With most test packages the associated report is more than one page in length It must therefore be possible to scroll between pages in a similar way to a PDF viewer It is also sometimes useful to change the size of the display zoom factor Gell Page 1 of 20 b b LOL 94 a G The icons on the left mean go to the first page go to the previous page go to the next page go to the last page The icons on the right mean reduce the size of the display zoom out increase the size of the display zoom in It is also possible to go directly to a specific page by entering a page number or to select a specific zoom factor by entering a value Icons for settings and help These icons are used to open the online help i e this manual or the dialog box used for making general settings for further details see also the description of the menu in chapter 1 4 1 Window Header and Menu on page 7 WEE Operating Manual 1175 6390 02 02 11 1 4 3 1 4 4 Main Window The icons mean open the help change the settings List of Test Cases This part contains the configuratio
6. which appears in the left hand window of the action editor is entered as the head ing in the preview window add PASS A FAIL criteria Adds the label PASS or FAIL to the beginning of the action item the label is determined as follows e f display measurement results is selected the limit violations defined for the measured values in the setup are checked e fa graphical window is selected the limit violations defined for the graph in the setup are checked PASS is only entered in the report if all of the checked conditions are met otherwise FAIL is entered add ZEN Inserts a hardcopy of the measured value display in the report as it racc Lu appears when configured in the setup and when open For each activated graphical window a hardcopy with labeling is show Sweep Graph added in the report provided that this graphical window has been show Impulse Response configured in the setup and is open The graph profile file color white is used for import to the report show FFT Graphi show PESO POLOQA Graphi show Bargraphl show Waveform 3 3 8 Store Results Stores selected results Store Results store Function Fesul x into my Function result R amp S UPx Sequencing Software R amp S Audio Measurements Package This action item allows selected results to be saved to a sequencer property e g a measured value or to a file on the device e g a frequency response for equalization The resul
7. 1 2 2 4 5 Load Setup Load Example Setup Rohde amp Se File Screens Instrument DispConfig Displays EU e G HM 1 2 x UPP Quick Start Panel Execute Macro SCPI Recording The three ways have the same effect Main Window This is the main window of the sequencer application It contains a menu 1 a toolbar with the usual icons 2 and a frame divided into two sections The right hand section of the frame displays a preview of the current test package 4 and the left hand sec tion shows all of the found test packages together with their test cases 3 Each pack age appears as an entry in the top level of the list This entry contains the name of the package The test cases contained in the package are entered hierarchically under this entry The R amp S Audio Measurements Package allows the configuration of user defined measurements User defined measurements are then sequentially processed by the R amp S UPx sequencing software see chapter 3 R amp S Audio Measurements Package on page 23 1 4 1 1 4 1 1 Main Window ad UPx Sequencing 2015 04 28T14 13 08 current database CACurrentTestData rssqdat 4 KIK ROHDE amp SCHWARZ 1 Configuration Project Identification Projet Title Project Comments 1 ProductName oO Manufacturer Model Number TY Date Completed Comments TY 2 User Defined Measurements 1 Window header and menu Toolbar
8. List of test cases wW yY Preview window Window Header and Menu The window header shows the name of the software followed by the ID of the currently selected test sequence UPx Sequencing 2U15 08 U5T13 43 56 File Testing Utilities The menu is described in the following subsections File Menu The File menu contains data management functions The settings test sequences and their results are stored in a database When the sequencer application is closed a new database is created New Database or a dif ferent database is opened Open Database any changes not yet saved can be saved or discarded after confirmation 1 4 1 2 Main Window Utilities Help Mew Database Open Database Save Database As Save Database Exit New Database This function resets the database to an empty version Any changes not yet saved can be saved or discarded after confirmation Open Database This function loads the content of a database stored on the hard disk after the storage location and filename for the database to be loaded has been queried in a file selection box Any changes not yet saved can be saved or discarded after confirmation Save Database As This function saves the database on the hard disk under a storage location and file name specified by the user Save Database This function saves the database on the hard disk under the current database name If no name has yet been g
9. Packages Settings Backups This submenu contains the functions used to save and restore backups Further details can be found in chapter 2 4 Creating Backup Copies on page 20 Packages This function opens a dialog box for management of the displayed test packages Fur ther details can be found in chapter 2 6 Management of Loaded Test Packages on page 22 Settings This function opens the configuration dialog box containing the global settings of the sequencer Global Settings The settings made here affect all installed test packages and are retained until they are changed by the user 1 4 2 Main Window a ConfigurationDialog POF previewer application Backup handling Ls Pn create backups every 0 days PDF preview application A PDF viewer installed on the audio analyzer can be specified here As soon as an executable is entered here the viewer will be started automatically each time a PDF report is generated If a preview has already been opened by the sequencer it is closed automatically beforehand Backup handling The automatic backup system is configured here Further details can be found in chap ter 2 4 2 Automatic Backup Copies on page 21 Toolbar The toolbar allows you to quickly access the most important functions of the sequencer It is divided into icons for data management for processing test cases for preview management and
10. are interpreted as the response Index A PCO e e 28 action attributes MN 32 attributes of action MEM isset neo teh a 32 comment for report sesenneseennsseninneerireenrrreenrrrserrrene 32 deleting action item jcinistasacvadiaanaieriandaeacinblenianiosvciatatoast 31 loading test plal E 30 moving QCHON MSN ME 32 New action Itel ege Oo 31 NEW test plan WE 30 renaming action item seeeeeeeeeeenennnenee 32 report COITIITIOT I arsimin neiaa 32 saving test leet etegteteftr bie edteggetee ege laria rii 31 Action item SIULA E E e EOE A E PAA EE E A A 32 delet WEEN 31 O e WEE 32 DEE 31 lan e WE 32 Action type Change Parameters 15er rent theta inea at tn gs 36 Existing Ee 33 Load SEUD NNI RR 35 EOOD B e EE 40 Beien ue EE 41 Remote e E 39 OD NEE 34 Setup Based Measurement soinssenneeenrorrerrrerrrrerren 33 Single Measurement cccccssssseeeeeceeeesseeeesseneeeeees 37 SEET enteteteeeedteg eege irois 37 E AN E 38 User Message eucnmiascuiittiaternwsidxdtsbisiasuni cat oot eda qeU ga 35 ACHON hue 32 ADVAN ME 21 Audio Measurements Package ccceeeeeeeeeeeeeeeeeeaeees 23 B Backup copies OMA G ebe T 21 e LW 20 Yl ANI EE 20 C Change Parameters ccccceccccssesceceseeceeeceeeeeesseaeeeeseaaees 36 Comment for report EE 32 Ee A TE 17 D Default setting cceccccccseecceeceeeeeeceeeeeeeseeeseeseeeeeeesaaeees 17 E Existing TestplanSs i
11. possible to transfer only test plans to other devices Test plans contain only the test sequences and not the measurement results Introduction This description is based on the assumption that the sequencer has been installed and started on the R amp S UPx The installation procedure is explained in the sequencer description under chapter 1 1 Requirements on page 5 and chapter 1 2 Installa tion on page 5 How to start the sequencer is described under chapter 1 3 Starting Sequencer on page 5 A whole range of controls becomes available after the sequencer has been started The following step by step instructions for creating a simple measurement task is intended to provide a simple introduction to operation Example 1 Test Plan with Two Setups In this example a database with just one single test sequence and one single test plan is created Two measurements are performed one after the other On channels 1 and 2 of the analyzer a frequency response measurement is performed followed by a THD mea surement The measurements are configured using the setups D UPV Setup Exam ples AA AA_Freq_Response set and D UPV Setup Examples AA AA_THD set These setups are available on the device as preconfigured demo setups They are called up by the sequencer one after the other The results of the measurements are saved in a result document as a PDF file Create a new data base 1 Select the File New Database menu 2 Enter the
12. 3 3 1 3 3 2 3 3 3 3 3 4 3 3 5 3 3 6 Sud 3 9 0 3 3 9 3 3 10 9 9 11 3 3 12 3 4 3 5 3 6 3 6 1 3 0 2 Saving the DATADAS P TP 28 ACION E UE 28 Creating New Test PIS cissccciisenisesnsabaiated wisseandoanedsaumncndientantenticeieaatednisdaswenaadbceenteniaiebeeancrsds 30 Loading Test Plan from File E 30 Saving Test Plan as E 31 Creating New Action lerm iii uiuere eor irt tir EE eege e read en Dese E 31 Deleting Selected Action Item E 31 Renaming Selected Action Item A 32 Moving Selected Action Items A Sg Defining Attributes of Action Hem 32 Comme tor REPO EE 32 ACUON Re 32 Existing TSS DANS eoan ae e ia a i E a a Eeit 33 Setup Based Meaeurement senes nn nn nna sns na nsn a ananas 33 ele E c RCPR 34 User Message sarisari X 39 EOG Oee ean E E OTT 39 Change ANIC USNS ee eege eeh 36 Seilen VE E 37 Store E 37 DEEDE i m A E E EE 38 Seet 39 POOR SONI EE 40 LOOD Res Le 41 Storing Results in PrOPSLile Ss ceieiescicscccsesiiscssnseucaancodeteaccaceveucseuobeswnadsannwoudaeneieberciemssweus 41 Using Results from Properties ccccssccesesseeesseeeseeeeeseeseeseeseeseeneesseneeesenneesenneeseens 41 PACKAGE espe H 42 Settings Tor Serial Interface 1 1 reor rte ren rater nun tran a crean aene sed s ep E doas 43 Settings T
13. Operating Manual U S ien 4 fu Snia son M4 cuir for PAPU Soniye dt ups HS A RR dat ue an E Ak Dh LI 10k m HI Frequency Hz Level Ch2 1V 1m m Time js D 500g n 15m gm 0 wai Sei E a Bou UPP 800 AUDIO ANALYZER OMORE rim IN 7 DIGITAL AUDIO KOM ANALOG IH a ANALOG OUT 77 ESET CASCADE LAN H 1175 6390 02 02 Operating Manual This operating manual describes the sequencing software for the R amp S UPx audio analyzers 2015 Rohde amp Schwarz GmbH amp Co KG Muhldorfstr 15 81671 Munchen Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R amp S is a registered trademark of Rohde amp Schwarz GmbH amp Co KG Trade names are trademarks of the owners The following abbreviation is used throughout the manual R amp S UPx is abbreviated to R amp S UPx 1 1 1 2 1 3 1 4 1 4 1 1 4 2 1 4 3 1 4 4 2 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 2 6 2 2 1 2 3 2 4 2 4 1 2 4 2 2 5 2 6 3 1 3 1 1 3 1 2 3 1 3 3 1 4 Contents SANO e 5 Ke UU dn EEN 5 BINS EN d Le EEN 5 Staring SeguUENCE EE 5 ET Rate le E 6 Window Header and Men NENNEN T TOODO EE 10 List of Ke 12 m
14. appears when the test sequence is started and must be confirmed by the user Include the first setup The setup for frequency response measurement and the associated measurement is included in the test plan 1 Click the 4th button from the left 2 Select Setup Based Measurement 3 Enter an action name e g Frequency response measurement 4 Click the paper clip A Windows file box opens 5 Select path to setup file D UPV Setup Examples AAMAA Freq Response set 6 Set the checkmark in the show Sweep Graph1 checkbox The measurement is triggered and the sweep graph is displayed in the report Every setup based measurement must be assigned an individual setup This is why an automatic check is performed when a preconfigured setup is selected The check establishes whether the setup is already present in the working directory of the sequencer In the example this is not the case Therefore a copy of the setup with prefixed consecutive number is created in the working directory when the setup is selected WEE Operating Manual 1175 6390 02 02 25 R amp S UPx Sequencing Software R amp S Audio Measurements Package Include the second setup The setup for the THD measurement and the associated measurement is included in the test plan 1 Follow exactly the same procedure as that described for the frequency response measurement The action name can be THD measurement for example 2 Set the checkmark
15. are applicable for the entire R amp S Audio Measurements Package are accessed by right clicking the main node Rohde amp Schwarz Audio Mea surements and then selecting the item Configure Test Cases BE Operating Manual 1175 6390 02 02 42 Package Settings a UPx Sequencing 2015 04 28T14 13 08 current database CACurrentTestData rssadat File Testing Utilities Help HRSA b bom u G or 4 Page 1 off b WA 10 eg a w Renee E E e a n h TT Rohda Schwan Estandad Audio Measurements EVI Configuration Select Test Cases m sm Enter Project Identification Jerit Tod Cae LIF Enter Product Identification B User Defined Measurements Configure Test Cases Jl show project identification Start Testing here Se show product identification SCHWARZ Default Selection 1 Configuration Settings for controlling external devices are made here These settings are independ ent of the selected test sequence and its configured steps These settings include the parameters for a serial COM interface and for a LAN interface as well as timeout val ues for communications with the R amp S UPx When this menu is selected the configuration dialog box for global settings opens They are grouped under the tabs Serial Port settings and LAN settings 3 6 1 Settings for Serial Interface Serial Port settings COM Settings Device Control COM Fot COMI Write Timeout sec 1 Fead Tment bed E0
16. ce settings 3 Comment window comments for report For certain action items comments can be entered here which are output in the report 4 Help and storage location of current template o Help for the sequencer e template for new sequences The action items of the test plan defined as the template are preset automatically as soon as a new test sequence is created 3 2 1 Creating New Test Plan 4 If changes have been made in the currently active test plan but these changes have not yet been saved a message is issued to indicate this 3 2 2 Loading Test Plan from File Loads a previously saved test plan and overwrites the current action list with it Any auxiliary files required setups limit files equalization files etc that are used in the test plan are automatically created in the data directory of the sequencing application The test plan loaded from the file is also used as a template for generating a default action list as soon as a new test sequence is started using in the main window After the test plan has been successfully loaded a query as to whether this test plan is in future to be used as the template for new test sequences is displayed Operating Manual 1175 6390 02 02 30 3 2 3 3 2 4 3 2 5 Action Editor Saving Test Plan as File Used to save the current action list as a test plan Any auxiliary files required setups limit files equalization files etc that are used in the te
17. d as a template for newly created test sequences Save test plan as file the test plan can then immediately be used as a template for newly created test sequences Create new action item Creation of a new action item A pop up menu appears in which the action type must first be defined Depending on the type of action item created the appropriate tab is acti vated in the right hand section of the dialog box and if applicable the attributes are pre set accordingly Delete selected action item Rename selected action item Move selected action items up or down The action items in the table above can also be triggered via a context menu that is opened by right clicking anywhere in the action window Clicking an action item R amp S UPx Sequencing Software R amp S Audio Measurements Package Configuration show project identification show p uct identification User Defined Measurements opens the associated attributes in the adjacent window on the right 2 These action items and their attributes are described from chapter chapter 3 3 Action Types on page 32 2 Attribute window definition of the attributes for an action item Clicking an action item in window 1 of the action editor opens window 2 in which attributes can additionally be defined for each action e g Section text of a head ing Setup Based Measurement device setup for a measurement or Change Parameter changes to specific devi
18. e to field underneath Start the measurement 1 Add the action item Single Measurement to the action list 2 Enter e g Single measurement as the action name 3 Setthe show Sweep Graph1 checkmark The sweep graph is displayed in the preview window Save the test plan 1 Click the 3rd button from the left tooltip save testplan to file A file box opens 2 Enter a different name for the test plan e g easy example filter in the sugges ted directory A file with the extension easy example filter rssqtp is created The test plan is now ready 3 Close the action editor using the green OK button Operating Manual 1175 6390 02 02 27 Action Editor Start the test sequence 1 Proceed in the way described under Example 1 Save the test plan on page 26 2 confirm the cabling instruction using the green OK button The sweep graph of the frequency response measurement appears on page 3 of the preview window It now displays a trace as if a DUT with a significant frequency response has been measured 3 1 5 Saving the Database As the test case now runs without error the task can be completed by saving the entire database so that it can be accessed again at a later time 1 Select File Save Database As above the toolbar of the sequencer A file box appears 2 Specify the desired directory and name e g D UPV USER Easy_Exam ple rssqdat in the file box 3 2 Action Editor
19. ected the test sequence can be started by clicking the Start testing icon All test cases to be processed are now col lected together and passed on to the associated test package File Testing Utilities B2 rc E v Configuration tp laz Enter Broch wt Ideni loi D During processing the main window of the sequencing application disappears so that the firmware of the audio analyzer underneath becomes visible This is because depending on the test package the operator may be required to for example perform adjustment of the DUT while at the same time observing the audio analyzer display To allow the test sequence to be stopped or interrupted while the main window is no longer is visible a status window is displayed in the bottom right hand corner of the screen This window has the following functions UPx Sequencing Procedure running a e The window shows that the sequencer is active the device should therefore not be operated manually e lf errors in the previous test case were noticed too late it is possible to move back step by step to the test case concerned left arrow icon e Inthe case of serious errors during the test sequence e g an unconnected cable the current test case can be repeated up arrow icon The main window can be opened again house icon in order to monitor results directly in the preview or to stop the test sequence Once the main window has been opened again it is p
20. ecuted are For example a sweep may first have to be completed on the audio analyzer before a package reacts to the request A certain period of time may therefore pass before a state permitting interrup tion is reached internally During this time the indicator in the status bar shows Stop ping or Halting see chapter 1 4 2 Toolbar on page 10 The request to repeat a test case or to return to the previous test case is also subject to the same conditions Normally the requests sent to the test packages affect a com plete test case as it appears in the test case list In addition to the above described reasons for delays a package manufacturer also has the possibility of subdividing packages further in the case of extremely complex test cases In such a case the request to repeat a test case or to return to the previous test case would only apply to a certain submeasurement within a test case Further details may be given in the test package documentation supplied by the respective manufacturer Storing Results as a PDF Report The print icon see chapter 1 4 2 Toolbar on page 10 allows the test results dis played in the preview to be stored as a PDF file Usually the PDF file is divided into chapters and subchapters which correspond to the structure of the test cases in their list A generated PDF can depending on the requirements of the manufacturer of the package contain form fields to allow further data to be entered
21. ed setup name are shown in the text box Changing the specified setup The firmware is instructed to load and display the setup The window of the firmware is then displayed in the foreground so that changes can be made As soon as the Sequencing icon in the firmware window is clicked the sequencing application is activated again and prompts the firmware to save the changes in the setup The name that has been given for this action item which appears in the left hand window of the action editor is entered as the heading in the preview window add item name as report header F add PASS FAIL criteria Adds the label PASS or FAIL to the beginning of the action item the label is determined as follows e f display measurement results is selected the limit viola tions defined for the measured values in the setup are checked If a graphical window is selected the limit violations defined for the graph in the setup are checked PASS is only entered in the report if all of the checked condi tions are met otherwise FAIL is entered Inserts a hardcopy of the measured value display in the report display measurement results as it appears when configured in the setup and when open P haw E Granhl For each activated graphical window a hardcopy with labeling is ligue added in the report provided that this graphical window has been configured in the setup and is open The graph profile file show Im
22. el CAR PT RO n EAAEENn 37 Storing results in properties eseseeeeeeees 41 T Temporary test data E EN RE E 17 RE 12 DEF Le E 15 PCS SUG e tr M M rosin emanates 15 starting INGIMIGU Al iii eesswvsd essa ditata ted a clus 2d Rasa 17 staring apr i Cz o NW Rm 16 IR e M H 21 Ee EE ER Test plan Uer ein e EE 30 ON ee 30 SIG ME PER 31 Test sequences WE E e EN 19 BSN ME 14 TST un EEN 8 TOO EE 10 U veer RE 38 User Message E 39 Using results from properties eeessssssse 41 IDEE e EE 9 W Window header and menu NENNEN 7
23. ends such a character processing of the subse quent action items can be continued immediately If this is not the case a certain time must be waited to see whether further characters are sent The waiting time can be set in the R amp S Audio Measurements Package PRESSE Name of the sequencing property in which the device response is to device ident i SEN my be stored If a property name is specified it must be ensured that the names are unique in each action list store into 3 3 11 Loop Begin This action item groups all further action items in the action list up to Loop End into a loop Loop Begin 20 H2 50 H2100 HZ1 KHz a KHz 10 KH2 20 KHz In the entry field the individual loop values for which the grouped action items are to be executed are separated by semicolons The most recent loop value in each case is R amp S UPx Sequencing Software R amp S Audio Measurements Package Ss ci 3 3 12 3 4 3 9 stored during runtime in the loop index property and can be applied anywhere using this property see chapter 3 5 Using Results from Properties on page 41 An informative text that also marks the individual steps in the report can be entered in the comment for the loop itself e g report comments setting gen frequency to lt lt loop index gt gt Loop End This action item marks the end of a loop started with Loop Begin No entries can be made here Loop End If this action item is missing a sta
24. eport comments window in the example shown below opens a context menu containing a predefined list of all properties defined in the cur rent action list Store Results into RMS Value B report comments eAMS Value gt gt ym Clear Copy Paste show Help Append Reference Configuration b mieingsdatasT estplans vwer easy example rssqtp Loops b Crew o ay Data Sets k The items Configuration and Loops are always present The items Results and Data Sets may also be available if properties have been generated using the action items Store Results and User Data When the desired property RMS Value in the example is clicked with the mouse it is inserted into the text box between double pointed brackets indicated by the red arrow This also applies without pointed brackets for the user data set editor see chap ter 3 3 9 User Data on page 38 Configuration Contains the properties that are defined in the configuration part of the Audio Measurements Package and can be entered via the test cases Enter Project Identification and Enter Product Identification Contains properties that are set using the action items Loop Begin and Loop End i Ld Data Sets Contains all properties that were created using the action item User Data Contains all properties that were created using the action item Store Results 3 6 Package Settings The package settings which
25. fining the set of properties CAUPxSequencing Data Results myuserdata tx ema Table Demo Property 1 aprop D test done on 2015 07 02 Demo Property Z bprop DUT is RES UPV 103266 The name of the data set is defined in the text box This then appears as the table heading in the report The three multi line text boxes underneath each contain one line for each property in the data set The left hand multi line text box contains the title for the property as it appears in the entry dialog box and in the table in the report The center multi line text box contains the property name as it can be used in the action list Here it is possible to enter new names or to use existing properties see chapter 3 4 Storing Results in Properties on page 41 and chapter 3 5 Using Results from Properties on page 41 If a property name is specified it must be ensured that the names are unique in each action list The right hand multi line text box contains the value currently stored for the property This value will be overwritten during processing of an action list if either enter dataset property val ues or save dataset property values is selected in the action item add dataset properties to report Generates in the report a table with the heading of the data set and with the current values of the properties enter dataset property values Allows the values of the properties to be entered in a dialog box by the user during runtime After t
26. for help and settings Icons for data management The principal data management functions include the creation and selection of test sequences as well as the selective storage of results in the currently selected data base The contents of the database are stored by default in the file currentTest Data xml on the C partition of the hard disk The filename and storage location can be changed at any time for further details see also the description of the menu in chap ter 1 4 1 Window Header and Menu on page The icons mean create a new test sequence select an existing test sequence store all current results in the data management The printer icon functions in a slightly differ ent way to the customary printer icon here all results are saved to a PDF report instead of being directly sent to the printer R amp S UPx Sequencing Software Startup X n Icons for test cases and status indicator These icons play a central role in sequencing They are used to start and stop auto matic processing of all selected test cases It is also possible to stop a sequence tem porarily if you do not want to leave more lengthy automatic test cases to run unsuper vised Further details can be found in chapter 2 2 6
27. gl tee M 12 Man al OBS d Oates nein ecacnonacaccedncanseiavasesxauncauenucntosasavanastneasesameateasanens 14 Selecting Test Sequences 1 EEN EEN RR KEE essei eee nennen nnn n nnn nnne nnn nnn nnns 14 Processing Test E 15 Wiuugei ue M T 15 Starting Marked Test CC ases nennen nennen nennen nnne nn nnn nnns 16 Starting Individual Test 28S iate ubi st Dre pe pA DES Netikmami iue pini di bampUb s suba AUR 17 Resetting Marking to Default Gettng sees 17 Context Menu of Test Caselet nenne nnne nennen nnnm nnns 17 Stopping and Interrupting Drocesseimg nnne 18 Storing Results as a PDF REDOFL TEE 18 Managing Test SequencesS ssssesssnsnnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn mennenm 19 Creating Backup TE 20 Manual Backup Ee EE 20 Automatic Backup EE ege ee Ee 21 Archiving Temporary Test Data ccccesceeseseeeeeeeeeeeeeseneeeeneeseseeeeseseeneesenaesenaensaaes 21 Management of Loaded Test Packages eeeeeeee eene enne nnne 22 R amp S Audio Measurements Package 23 cenno Rn E 23 Concept of R amp S Audio Measurements Package 23 EO ie Uleila css PEE 24 Example 1 Test Plan with Two Getupne nnns 24 Example 2 Changing Test lan 27 3 1 5 3 2 3 2 3 2 2 3 2 9 3 2 4 3 2 5 3 2 6 3 2 7 3 2 8 3 2 9 3 3
28. h for UPP R amp S UPP UPx Sequencing Setup Version 1 2 xxxxx The R amp S Audio Mea surements Package is also installed see chapter 1 4 Main Window on page 6 Microsoft Net Framework 3 5 must already be installed on the device If you are not sure whether this is installed simply call the installation file If Net Framework is not installed the error message This setup requires the NET Framework version 3 5 Please install the NET Framework and run this setup again appears and NET Framework must be downloaded from the Microsoft homepage and installed http www microsoft com en us download details aspx id 25 150 1 2 Installation Run UPxSequencingSetup 1 2 xxxxx exe and select Local Install and then Next Install Exit 1 3 Starting Sequencer There are three ways to start the sequencing software from the R amp S UPx firmware e Using the test sequence icon on the toolbar Operating Manual 1175 6390 02 02 5 1 4 e Using the File menu Main Window mande ex schwarz Audio Dnabheeer Udo screen 3 d isubysusersupx X i DispConfig Displays Sequences Utilities Windows Help 2EOUenmCIPnOvO ataNAEUDS 0 ar rre File Screens Instrument tU ep HFG amp b UPP Quick Start Panel bake e m sayari Dis Ee d An alan L RMS via FFT Fr e 6 fy 0 037 ET Rohde amp Sc DispConfig Displays Sequences Util Preset Load Default GH
29. he action editor is entered as the heading in the preview window add item name as report header 3 3 6 Change Parameters Changes up to four different specifically selected device settings Change Measurement Parameters set Generator Sweep el Start Frequency o 100 HZ set Generator Sweep Stop Frequency MM to 10 KH Starting out from a loaded setup see chapter 3 3 2 Setup Based Measurement on page 33 this action allows up to four different specifically selected device settings referred to here as parameters to be changed before the next measurement is per formed in a subsequent action This action item is particularly useful in cases where parameter switchover with subsequent measurement is to take place several times with one loaded setup A predefined selection of parameters is available If the desired parameter is not available this setting must be made in a self configured setup which is loaded using the action item chapter 3 3 2 Setup Based Measure ment on page 33 and immediately followed by a measurement The parameters to be changed are each selected using the left hand combo box With some parameters e g Generator Sweep Start Fre quency in the example two level selection takes place using the right hand combo box in order to limit the number of list entries The options available under the left hand combo box depend on the selec tion made under the right hand combo b
30. he values have been successfully entered they are stored in the user data set in the specified file load dataset property values Loads the values of the properties defined in the user data set from the specified file save dataset property values Saves the values of the properties defined in the user data set to the specified file when the test case encounters this user data action item 3 3 10 Remote Control Remote control of external devices Action Types Remote Control remote interface LAN Interface e idn 7 append LF append CH get Answer answer terminated with LFACR store into my device ident This action item allows remote control of external devices either via the serial COM interface or via LAN Serial Port remote interface Control of the device via RS 232 C with the settings defined in the R amp S Audio Measurements Package LAN Interface Control of the device via LAN with the settings defined in the R amp S Audio Measurements Package Control command for the device impedi 00 Specifies whether the line feed character 0xA is to be appended Specifies whether the carriage return character OxD is to be appended Specifies whether the device sends a response and whether this response is then to be read in at the interface answer teminated with LF CR Specifies whether reading in of the response can be terminated by a line feed Oxa or carriage return Oxd e fthe device s
31. in a postprocessing WE Operating Manual 1175 6390 02 02 18 Managing Test Sequences stage As soon as the generated PDF contains headings and subheadings the book mark list for the PDF reader is also updated accordingly When PDF export is started a file selector appears that allows the user to enter a stor age destination In the example of a generated PDF file shown below it can be clearly seen that the Report Number field is to be filled during postprocessing of the finished report Product Identification Ss o e Ise Laboratories D Materials Receive meme 8 mE Trademark Usage Paces om mew Is D Output Connections Check All That Apply IC information D supported Broadcast maa WI Pulse pe Standards LP Modulator Settings P Input Connections Materials Received tested Check AII That Sehemaidagams C Block diagrams 8 ll 825x1L69in asl Losssssssssssssssuu 2 3 Managing Test Sequences The list of all stored test sequences can be called via the menu item Manage test sequences Mew best sequence select test sequence Manage best sequences mA L Materials Received In the dialog box that appears it is possible to delete test sequences that are no longer required In addition temporary data of old test sequences can be archived or dearch Wed in order to save space on the built in hard disk 2 4 2 4 1 Creating Backup Co
32. in the show Bargraph1 checkbox The measurement is triggered and the bargraph is displayed in the report Save the test plan 1 Click the 3rd button from the left tooltip save testplan to file A file box opens 2 Enter a name for the test plan e g easy example in the suggested directory A file with the extension easy example rssqtp is created The test plan is now ready Start the test sequence 1 Click the small box with the sign to the left of User Defined Measurements in the sequencer window A tree structure is displayed in which the individual steps of the test plan are shown In this tree structure it is possible to see whether the test sequence was performed successfully This tree structure also provides debug options however these options are not explained in this simple example 2 Right click the User Defined Measurements node A context menu opens 3 Click item Start Testing here The test sequence is started and the cabling instruction appears immediately 4 Confirm the cabling instruction using the green OK button After a few seconds the measurement results appear in the form of a sweep graph and bargraph in the right hand window The sweep graph shows a straight line The result report consists of two pages which can be toggled using the blue arrow buttons in the toolbar of the sequencer window Save the measurement results as PDF file 1 Click the printer icon 4th icon fr
33. ities Backups k Settings This function is required if different test packages are installed in an audio analyzer Since each loaded package has its own tab in the preview operation becomes awk ward if too many are visible Normally only a small number of packages are required to perform certain tests In this case those packages that are not required can be hid den until a different type of test becomes necessary A dialog box opens in which all installed packages with their delivery version number are displayed The required packages can be selected by selecting the checkboxes on the left hand side When the sequencer is restarted only these packages will then be available Operating Manual 1175 6390 02 02 22 Getting Started 3 R amp S Audio Measurements Package The generation of measurement reports for several different sequential measurement tasks Is the task of the sequencer for the R amp S UPx audio analyzer the two figures below show examples 1 Setup Multitone Wav Measurement 2 Setup Multitone FFT Measurement Trein Waebmm of Input S kage ork for saral no A uml lt packag np ath gt Setupe D __mutitonewew set 3 1 Getting Started 3 1 1 Concept of R amp S Audio Measurements Package The user creates a setup for each measurement task The sequencer loads this setup and then automatically performs a single measurement The results of the measure ment are stored i
34. iven the storage location and filename must be specified in a file selection box Exit This function closes the sequencer Changes can be saved or discarded after confir mation Testing Menu The Testing menu contains functions for test sequence management The preview and PDF generation always relate to an entry selected within the data management al UPx Sequencing 2012 01 18T11 54 26 Utilities Mew kest sequence select test sequence Manage tesk sequences pa ae Ge Dutput nd New test sequence This function creates a new test sequence with the current timestamp All results in the preview window are deleted and the status of the individual test cases is reset to not performed in the test case list 1 4 1 3 1 4 1 4 Main Window Select test sequence This function is used to select an existing test sequence All existing results are shown in the preview window and the most recent status of the individual test cases is restored in the test case list Further details can be found in chapter 2 1 Selecting Test Sequences on page 14 Manage test sequences This function is used to delete test sequence results that are no longer required Fur ther details can be found in chapter 2 3 Managing Test Sequences on page 19 Utilities Menu The Utilities menu contains management functions for backups and loaded test pack ages and the global settings A d Backups E
35. n a report usually in the form of a graph This basic concept also provides possibilities for intervening in the process e g changes made to settings following the creation of the setup loops or individual mea surements decoupled from the setup as well as action items that influence the appear ance of the report see chapter 3 2 Action Editor on page 28 The sequencer allows multiple test sequences to be created in order to for example measure an amplifier an equalizer and a transmission path It is possible to create multiple test plans that determine the actual measurement task in order to for exam ple adapt the generator output level of the R amp S UPx to the various DUTs The mea surement results of a test case are saved in a test sequence and can be viewed at any time Test plans are not bound to specific test sequences If necessary a test plan can be used for several test sequences All test sequences setups data sets test plans and results can be saved as a data base in a single file and thus archived so that work can be performed alternately on R amp S UPx Sequencing Software R amp S Audio Measurements Package WEEN different test cases at any time This database file can be forwarded to other R amp S UPx devices so that the test cases can also be performed on these devices and the results can be viewed If database export is not desired because measurement results of DUTs could then fall into the wrong hands it is
36. n section and the test plan test plan collection of measurements for the currently selected test sequence When the software is started for the first time the test plan may be empty depending on the test plan loaded The list of test cases performs several functions simultaneously The list in the illustration below indicates that Enter Product Information has been performed successfully and that IC Information has been terminated and must be performed again Materials Received and Trademark Usage have not yet been per formed a Mi Configuration D Enter Product Identil e v C IC Information 2 Materials Received Pu Trademark Usage L In the illustration below Channel Identification has been terminated with an error this result will cause the test package to be marked with FAIL in the report amp v E33 Listening Tests Be kel Standard Listening T 00 E Channel Identifica f ml Preview The preview is the most important function after the icons for processing the test cases The results for each processed test case are immediately shown here Preview follows the WYSIWYG principle The individual pages in the preview are identical to the pages in the PDF report generated later By scrolling through the preview you can immediately see the points at which a test case has not yet been processed empty fields see the illustration and whether the obtained results are plausible
37. ng Selected Action Items Moves a selected action item up or down thereby changing the order in which action items in the test plan are processed Defining Attributes of Action Item Clicking an action item in window 1 of the action editor opens window 2 in which attrib utes can additionally be defined for each action item e g Section text of a heading Setup Based Measurement device setup for a measurement or Change Parame ter changes to specific device settings Comment for Report report comments This grafik shows the frequency response of the DUT xyz For each action item with the exception of Loop End it is possible to enter a com ment here this comment appears in the preview window after a test case has been completed Line breaks are inserted in multi line comments Properties can also be entered here see chapter 3 5 Using Results from Properties on page 41 Action Types Determines the type of action item in the test plan 3 3 1 3 3 2 Action Types Existing Testplans setup Based Measurement Section User Message Load Setup Change Parameters single Measurement store results User Data Remote Contral Loop Begin Loop End A test plan can contain a large number of action items The action types described below determine which action items are available to be included in the test plan Existing Testplans Inserts the action items from a test plan A further pulld
38. ocos o brin mo osea tnp xen NT bnE Geiewercceeds KS E e ET EE Z G Getting started WE 23 Global settings E 9 42 LAN Hinger 44 serial interface RM 43 l ASAAN EE 5 L LAN interface ccccccccceeseeceeeeeeeeeeteeeeteeeetseaeeteneeeteneeeees 44 List of test cases ccssescescesncssansaesssuesanescessanencsuanstatesanssnaenaseed 12 Load Setup E 39 LOOP M ea EE 40 Reie 41 M Main WINGOW ccceccceeceesceceeeeeeeeseeeeeueetegeeeceteneeeeeeseeeeanes 6 list of test cases oo ccccccceeecceceeeeeeceeeeeeeseeeeeesaeeeeeees 12 E 12 ee le EE 10 window header and menu seeeeeeneeee T WE et EE ER Manual operation EE 14 MIRO NEE 17 O Eeer 14 P BU io 18 mi APPS 12 Processing let ei dl M 18 Ee 18 R Remote e E 39 Report Comment eebe Eege 32 Requirements for startup ccccccccccceecceeceeeeeeeseeeeeseeeeeees 5 Results from properties USING ccccsseececeseeeeeeaeeeeeees 41 Results STONG MT mmm 18 Results storing in properties eseseeese 41 S or MER 34 Sequencer starting WE 5 Seral Ie e 43 Settings LAN Ki le 44 serial interface eebe ENEE 43 Setup Based Measurement cccsecceeeeeeeeeeeeeeseeeeaeeees 33 Single Measurement une ne ena nh rn ter rie o 37 Starting sequencer eegene 5 e EE 5 Ge Ee Lu EN TRE o 9 ATEEN TSS EE 6 ellen EE 9 starting Sequencer E 5
39. oes not affect a test sequence that is already being processed Context Menu of Test Case List The context menu is already shown in the previous section A detailed description of the functions is given below R amp S UPx Sequencing Software Manual Operation e M 2 2 6 2 2 7 Select Test Cases If a branch containing further subentries is selected in the test case list all entries in the next lower level are marked Other sublevels are not changed Deselect Test Cases If a branch containing further subentries is selected the markings of all entries of the next lower level are removed Other sublevels are not changed Execute Test Case A test case is started as soon as it is selected using the left hand mouse key In all cases processing is then performed irrespective of the last result Start Testing here As soon as a test case is selected using the left hand mouse key testing starts with this test case In this case the list is not searched for the first as yet unprocessed test case that does not have PASS as its result Default Selection The marking of the test cases is reset to the default setting defined by the test package manufacturer Stopping and Interrupting Processing The request to stop or interrupt a list of test cases is forwarded by the sequencer to the test packages The time taken for all test packages to respond to this request depends on how complex the operations currently being ex
40. om the left in the toolbar of the sequencer window 2 Enter the path and file name for the PDF 3 Confirm with the OK button Operating Manual 1175 6390 02 02 26 R amp S UPx Sequencing Software R amp S Audio Measurements Package 3 1 4 Example 2 Changing Test Plan The test plan of example 1 is changed A DUT is simulated by switching on a filter in the analyzer The setup for the frequency response measurement remains unchanged However the A weighting filter is switched on by means of an action item Adopt the setup for the frequency response measurement in the test plan 1 If the sequencer has been closed in the meantime call it again The sequencer opens with exactly the same settings that it had when it was closed i e both the test sequence that has just been performed as well as the associated test plan are present 2 Open the action editor 3 Click the 4th button from the left select Load Setup and enter an action name e g Frequency response without measurement 4 Inthe right hand section select the storage location and setup name D UPV Setup Examples AA AA_ Freq Response set 5 Add the action item Change Parameters to the action list 6 Enter e g Switch on A weighting filter as the action name A window containing attributes opens on the right hand side 7 Select the item Analyzer Filter in the set field at the top left by using the small arrow 8 Select A Weighting in th
41. or LAN Interface eoe rn retra Diod cesse d ee nma loea a and o da gege ENdEE eben 44 Ine e 45 R amp S UPx Sequencing Software Startup 1 Startup The R amp S UPx sequencing software consists of a main program that is responsible for data management processing the test sequences and compiling reports This main program referred to below as the sequencer also manages the user interface All test cases are kept in loadable modules referred to below as test packages When started the main program can load and display any number of test packages The test packages are installed in the subdirectory specifically intended for them The user can however also determine which packages are to be loaded Further information can be found in chapter 2 6 Management of Loaded Test Packages on page 22 To process test cases a test sequence must first be created or an existing test sequence must be selected Each test sequence has a unique ID that is based on the timestamp generated when the test sequence was created All results that are entered in dialog boxes or obtained from automatically performed measurements are stored in the data management under this ID and can be called up again at a later time 1 1 Requirements An installation file with the name UPxSequencingSetup 1 2 xxxxx exe is required The latest version can be found at www rohde schwarz com Quick Links Firmware searc
42. ossible to terminate processing by clicking the Stop testing icon File Testing Utilities LS Nal Nok Eifel Configuration EN WU Crder Predict Iden The Suspend testing icon interrupts processing until the operator returns to the work place and continues processing again by clicking the same icon Operating Manual 1175 6390 02 02 16 2 2 3 2 2 4 2 2 5 Processing Test Cases File Utilities Testing Ga Configuration TT e E rte Pradit Ideni Details on stopping and interrupting can be found in chapter 2 2 6 Stopping and Inter rupting Processing on page 18 Starting Individual Test Cases Individual test cases can provided that a test sequence is not currently being pro cessed be started directly at any time by selecting the test case concerned in the test case list using the left hand mouse key and then calling the context menu using the right hand mouse key Identific Select Test Cases Deselect Test Cases Start Testing here Default Selection Resetting Marking to Default Setting If Default Selection is selected in the context menu of the test case list the marking of the displayed test cases is reset to the default setting defined by the package manu facturer Select Test Cases Deselect Test Cases Execute Test Case Start Testing here Modulator Settings Q Resetting the test case marking d
43. own menu opens containing a list of all test plans that can be found in the directory intended for the test plans D UPV User UPxSequencing Data Testplans and in all lower level directories Selecting one of these test plans appends the action items saved there to the end of the current action list Each action item can be moved to the desired position within the current test plan using the blue arrow icons Setup Based Measurement Loads a setup and automatically performs a measurement Setup Based Measurement add item name as report header display measurement results show Sweep Graph show Impulse Response show FFT Graph show PESG POLGA Graphi show Bargraphi add PASS FAIL criteria show Waveform This action item loads a setup and automatically performs a measurement The check boxes display measurement results or show determine whether a graphical dis play is shown in the preview window R amp S UPx Sequencing Software R amp S Audio Measurements Package Selecting a device setup on the hard disk To ensure that the integrated backup procedure functions correctly see chapter 2 4 Creating Backup Copies on page 20 and test plans are saved correctly a copy of the selected setup is created in the working directory of the sequencing application and a consecutive number with hyphen is added to the setup name to enable multiple identical setup names to be distin guished from each other The storage location and the extend
44. ox set Generator Sweep e Numerical values a filename or a reference to the sequencer property can be specified as parameters see chapter 3 5 Using Results from Properties on page 41 Numerical values can be specified with or without a valid unit of measurement Decimal places must be separated by a decimal point using a comma will cause an error message to be issued to IDRHZ e The buttons to the right of the entry field for the value each allow a file that is already on the hard disk to be selected The user interface ensures that a copy of a selected file is made in the working directory of the sequencing software and that this copy is specified so that the inte grated backup procedure functions correctly see chapter 2 4 Creating Backup Copies on page 20 and test plans are saved correctly WEE Operating Manual 1175 6390 02 02 36 Action Types 3 3 Single Measurement Performs a measurement with the current settings Single Measurement add item name as repart header display measurement results show Sweep Graph show Impulse Response show FFT Graph show PESG POLGA Graphi show Bargraph add PASS FAIL criteria show waveform This action item starts a measurement with the current settings The checkboxes dis play measurement results or show determine whether a graphical display is shown in the preview window add item name as repart header The name that has been given for this action item
45. path and name for the data base Create a new test sequence 1 Select the Testing New test sequence menu A dialog box appears which can be filled out as required 2 Fill out the dialog box If no entries are made the new test sequence only has a timestamp as its name The Testing select test sequence menu on the toolbar of the sequencer can be used to check whether the test sequence has been configured correctly WEE Operating Manual 1175 6390 02 02 24 R amp S UPx Sequencing Software R amp S Audio Measurements Package WEEN Create a new test plan 1 Right click the item User Defined Measurements A context menu opens 2 Click item Configure Test Cases The action editor opens It is used to create individual action items and save them in a test plan 3 Three action items are entered in this example e Cabling instructions for the user e Loading the frequency response setup and performing a measurement e Loading the THD setup and performing a measurement 4 Click the 4th button from the left tooltip append new item A pulldown menu opens 5 Click the item User Message 6 Enter a meaningful name for the action e g Cabling instructions A further entry field now appears in the right hand part of the action editor 7 Enter the wording of the cabling instruction e g Connect generator channels 1 and 2 and analyzer channels 1 and 2 using XLR cables This message
46. pies ud Manage test sequences i mz 2012 01 18T11 54 26 UPP800 100145 Rohde Schwarz Illich mem 2012 01 25T15 38 49 UPV 105767 Rohde amp Sck z temp files in DAUPMIUSERWWUPs Sequencing iReports201 2 01 25 T15 3 43 D bytes used last update was 01010001 DU OU DU Archive temp files alder than 26 December 2011 Restore temp files from Archive Clicking the Delete button completely removes following a query the selected test sequence from the data store All temporary files e g hard copies that the test pack age has created for this test sequence are also removed For information on the archiving function see chapter 2 5 Archiving Temporary Test Data on page 21 Creating Backup Copies Software that over a long period of time collects data that the customer may require for certification reasons must of course provide mechanisms for creating backup copies It must be possible to temporarily store complete results of past test sequences together with any existing temporary data e g hard copies on another physical storage medium or network drive Manual Backup Copies Manual backup copies are created and restored via the Utilities menu oH UPx Sequencing 2012 01 18T11 54 26 File Create Backup Packages Restore Backup A SE Product Identifi Create Backup The path and name of a backup container to which the test results and temporary files of all test sequences are w
47. pulse Response es color white is used for import to the report E show FFT Graphi show PESG POLGA Graphi 1 show Bargrapht show Waveform The specified results are displayed in the report The various options are described in detail in chapter 3 3 8 Store Results on page 37 3 3 3 Section Generates a heading in the report Section Heading LIT Cha Ier Subsection Operating Manual 1175 6390 02 02 34 R amp S UPx Sequencing Software R amp S Audio Measurements Package This action item inserts a heading in the report As with a text processing application there are different levels that are represented by corresponding numbering and font size If a new section of the next higher level is defined the number of the level underneath is reset in the usual way The hierarchy levels of the headings are also inserted hier archically in the generated PDF file as bookmarks When headings are assigned it is important to always observe the sequence Chapter Section and Subsection Chapter A chapter is the highest level and is automatically assigned a consecutive number Section A section is the second level and is automatically assigned the chapter number plus a con secutive number Subsection A subsection is the third level and is automatically assigned the chapter number the section number plus a consecutive number 3 3 4 User Message Shows a message with instructions Use
48. r Message Please connect Gen Ch1 Ch2 to Analzyer Chi Cha While an action list is being processed this action item shows a message with instruc tions for the user a cabling instruction in the example 3 3 5 Load Setup Loads a setup without a measurement being performed Load Setup dup WuserupesegquencingsdatasS etups 0 Q5P_FFT set EE add item name as repart header Selecting a device setup on the hard disk To ensure that the integrated backup procedure functions correctly see chapter 2 4 Creating Backup Copies on page 20 and test plans are saved correctly a copy of the selected setup is created in the working directory of the sequencing application and a consecutive number with hyphen is added to the setup name to enable multiple identical setup names to be distin guished from each other The storage location and the extended setup name are shown in the text box Changing the specified setup The firmware is instructed to load and display the setup The window of the firmware is then displayed in the foreground so that changes can be made As soon as the Sequencing icon in the firmware window is clicked the sequencing application is activated again and prompts the firmware to save the changes in the setup Operating Manual 1175 6390 02 02 35 R amp S UPx Sequencing Software R amp S Audio Measurements Package The name that has been given for this action item which appears in the left hand window of t
49. ritten are specified in a file selection box 2 4 2 2 9 Archiving Temporary Test Data Restore Backup The path and name of a backup container from which older data is to be restored are specified in a file selection box For safety reasons a backup copy of the current data is created automatically beforehand For further details see also the following section Automatic Backup Copies In the Settings dialog box creation of automatic backup copies can be activated by entering a path for the backup archives in the Backup handling field and setting an interval in days a ConfigurationDialog amz PDF previewer application a a e SE handling CT an create backups every 0 days Whenever the sequencer starts a check is made to see whether the interval since the last backup has exceeded the interval setting If this is the case a new backup archive with the name testResults_ lt timestamp gt is created automatically in the specified path Archiving Temporary Test Data Over time the data management fills with a large number of test sequences for which depending on the type of test packages used temporary data e g in the form of hard copies is also generated The archiving function addresses the problem that at some point the hard disk of the audio analyzer may no longer have enough space on its data partition to store further data In the example illustration below approx 2 MB of data e
50. rted loop always runs to the end of the action list Storing Results in Properties All results that can be queried using an action item in the sequencer are stored either in a property e g measured values or directly as a file on the hard disk e g fre quency responses A store attribute consisting of two combo boxes used to select which result is required and an info attribute in whose text box a user selectable text can be entered are provided for this purpose in the Store Result action item see chapter 3 3 8 Store Results on page 37 on the right hand side of the action editor e If the entry is a valid filename and this filename is located below the working direc tory of the sequencer the data is stored there e lf the entry is not a valid filename this entry is used as the name for a new prop erty In this case the name must not contain a colon nor double pointed brack ets e g lt lt or gt gt The next chapter explains how this property can be used Using Results from Properties During runtime the value of a property can be inserted in all headings attribute fields and comments by inserting the name of the property into the text between double poin ted brackets This does not need to be done manually but instead using a convenient context menu WEE Operating Manual 1175 6390 02 02 41 R amp S UPx Sequencing Software R amp S Audio Measurements Package Right clicking a text box r
51. st plan are automatically stored in the test plan This allows test plans to be exchanged between devices of the same type A test plan should preferably be saved in the directory that is suggested by default in the file box D UPV User UPxSequencing Data Testplans xxx rssqtp Test plans saved there can be saved manually or automatically using the integrated backup pro cedure see chapter 2 4 Creating Backup Copies on page 20 To allow test plans to be imported to other devices the test plans can of course also be saved to other drives and directories e g to a USB flash drive The newly saved test plan is also used as a template for generating a default action list as soon as a new test sequence is started using in the main window Creating New Action Item Opens a pop up menu that displays the available action types Existing Testplans setup Based Measurement Section User Message Load Setup Change Parameters single Measurement store results User Data Remote Control Loop Begin Loop End Selecting a menu item appends the corresponding action item to the end of the list The action item can then be moved to the desired position within the test plan using the blue arrow icons Deleting Selected Action Item Deletes the selected action item from the action list 3 2 6 3 2 7 3 2 8 3 2 9 3 3 Action Types Renaming Selected Action Item Used to rename a selected action item Movi
52. t to be stored is determined using the left hand combo box With some parameters e g Function Result Ch 1 in the example two level selection takes place using the right hand combo box in order to limit the number of list entries It is also used to perform adjustment processes that do not return a result in the first step e g Select Graphics Cursor Sweep O Cursor Only then is it possible in a second step to retrieve the result with Graphics Cursor Y value of and Max and to specify the property name The storage location can either be the name of a property see chap ter 3 4 Storing Results in Properties on page 41 or a file on the hard disk If a property name is specified it must be ensured that the names are unique in each action list into my function result The buttons to the right of the entry field for the storage location each allow a file to be specified it is possible that this file will then be overwrit ten The user interface ensures that a specified file is always created in the working directory of the sequencing application so that the integrated backup procedure functions correctly see chapter 2 4 Creating Backup Copies on page 20 and test plans are saved correctly Values that are read out here must have been activated and updated in the used setup e g reading out of Level Monitor Result Two action items are needed to read out Y values because the readout operation actually in
53. the marking is removed from all fully processed test cases so that these test cases are not processed again if testing is restarted The marking can of course be changed manually at any time either individually for each test case or for a complete branch via the context menu of the test case list Using the context menu it is also possible to start processing at a particular test case or to process one single test case even if it is not marked Marking Test Cases Test cases are marked by selecting the checkbox on the left hand side of the list entry b a lot o kk Configuration oe Enter Product Identil w f amp IC Information 5 Materials Received ef Trademark Usage L 7 C Trademark Usage T Trademark Usage F Output Connections 2 Modulator Settings 2 The illustration shows that IC Information Material Received and Output Connec tions are marked all other test cases are not marked R amp S UPx Sequencing Software Manual Operation If a branch with lower level test cases is not marked none of the lower level test cases will be processed even if these test cases are marked Entire branches can be marked and unmarked using the context menu of the test case list It is also possible to reset the marking of the test cases to the default setting prede fined in the test package from the manufacturer 2 2 2 Starting Marked Test Cases When all desired test cases have been correctly sel
54. volves three steps A graphical window and a cursor must therefore first be selected and then read out at the specified X position The graph and cursor must be set visible in the used setup e g FFT graph open Post FFT switched on vertical O Cursor on Trace A 3 3 9 User Data Uses a user data set User Data DAUPYAUSE RSUP sS eguencing D ata Aesults0 M eimi E rstenL serD ata add dataset properties to report load dataset property values O enter dataset property values save dataset property values This action item enables a user data set to be used in measurements and in the report This can be for example a calibration data set that was previously created by a differ ent test sequence or test plan even on a different device A user data set is a file on the hard disk that defines a set of sequencer properties with associated titles and val ues WE Operating Manual 1175 6390 02 02 38 Action Types Allows a file to be specified it is possible that this file is then overwritten The user interface ensures that a specified file is always created in the working directory of the sequencing appli cation so that the integrated backup procedure functions correctly see chapter 2 4 Creating Backup Copies on page 20 and test plans are saved correctly Allows an existing user data set to be used The button to the right of the entry field for the used data set opens a user data set editor for de
55. xist for the test sequence of user Mayer R amp S UPx Sequencing Software Manual Operation WEEN gi Manage test sequences aa 2012 01 18T11 54 26 UPPanD 100145 Rohde amp Schwarz Illich ablizsz Hl z2zsTI5 s80 4d9 UPM 105767 Rohde amp Schwarz Mayer temp files in CAUP SERUP Segquencingigepartsieut 2 01 26 T15 3 43 2017211 bytes used last update was 2540172012 16 22 01 Archive temp Files alder than 2 December 2011 Restore temp files fram Archive The Archive temp files older than function allows the temporary data of all stored test sequences to be moved from the hard disk to an external archive provided that this data is older than the specified date The path and name of the target archive are specified during the archiving process From now on the data is in this archive and no longer on the hard disk of the audio analyzer If at a later time the results of an older test sequence are required again they can be extracted from this external archive again by clicking on Restore temp files from archive The desired test sequence is then selected in the list and the restore func tion is executed The path and name of the source archive are specified during the importing process 2 6 Management of Loaded Test Packages Test package management can be called via the Utilities menu in order to hide test packages when the program is started oJ UPx Sequencing 2012 01 18T11 54 26 File Testing Util