Home
AGRETO Three-Point-Scale Manual with B300 indicator
Contents
1. As in common parlance the word load is used instead of mass in this user manual 2 Scope of delivery Standard scope of delivery Steel construction with built in load cells 2 top link brackets with 160 mm hole spacing 2 top link brackets with 130 mm hole spacing 1 top link and 2 lower link pins with linchpins Weighing indicator with connecting cables This user manual Optional accessories m Lower link hook instead of ball ends connection eyes m 3 5 or 10 m extension cable for the weighing signal m Two line B400 weighing indicator with distance sensor instead of the standard single line B300 weighing indicator E Connecting cable to the signal socket for the speed signal only in combination with the B400 weighing indicator AGRETO electronics GmbH Seite 3 AGRETOtweepointsale ALO 3 Intended use The AGRETO three point scale is a scale for weighing three point implements and or their loads It s mounted at the three point linkage between tractor and implement Tractors with Category II and Ill top links and lower links are suitable but only Category Il implements can be attached Only implements with a total weight of 6 000 kg can be attached The scale must be set to the exact same mounting height as the attached implement The implement can only be connected to the scale via the two lower link pins and the top link pins No significant push pull forces must be transferred which means that soil
2. 7 1 Switching on the weighing indicator Switch the weighing indicator on with the button on the far left The indicator shows a start up sequence followed by the scale s actual load based on the most recently set zero point a ee ZERO TARE GROSS NET PRINT 7 2 Zeroing The ZERO button resets the indicator s zero point Use this function for zeroing the scale with an attached and raised implement This puts the zero point on the implement s empty weight after which a load s weight can be read directly 7 3 Standard weighing procedure Load and unload the implement or use your implement as usual and the load s actual weight will be displayed immediately on the weighing indicator The indicator is stabilized which allows you to read the weight while driving AGRETO electronics GmbH Seite 14 AGRETO thee pointscale ALO 7 4 Weighing with tare function If you would like to weigh goods in containers or packages the weight of these containers or packages can be automatically subtracted using the tare function without changing the scale s zero point E Make sure that the indicator reads zero E Put the container or package on the scale m Wait until the weighing indicator displays a stable value m Press the TARE button The weighing indicator reads zero again and displays the NET symbol Now the weighing indicator will only show the additional load net weight Put the goods in the container Wait until
3. User manual AGRETO three point scale with B300 weighing indicator 27 January 2014 ATTENTION Read the operating instructions in this user manual before operating the equipment for the first time in order to prevent damage to your scale or implement AGRETO electronics GmbH AGRETOteepointsale ALO Table of contents 1 NOG MIC MOM aces orc otiet en E A T Leek Guus esate 3 2 108 01Sa NEE ENEN EE EE E E A 3 3 WILGRICS CIS Gi causa Niee cia via madad n aA N A A A E 4 4 SASE e a E E E he Rh a a 5 4 1 Safety guidelines for the UCASE uc srcotat neat corsets date satus ates anutend alee y seagrass 5 4 2 Safety guidelines for operating and assembling personnel 5 5 Teo EEE E EE E E EEEE ETE E 7 6 CTEM SEA LC Ce sea cen taht ca E dad a E A E 10 6 1 Setting lower IK AS AOS ail taste et hae ce Saleh Mean a a 10 62 Setting mounting Aeg Atena els w radeon tatu ae tava hs Mae AA 10 6 3 Mounting the three point scale oar ve Mader teat ei atas vie devel eve Ne Vales 12 6 4 Connecting the weighing INCICALOR wacse vac icer ty eu racerat ates ait dere bed evant ve Vea 12 7 Weighing indicator resan asea rer pent Ree ee Cre cee nee a Oe Beer aE ae ai a Dee 14 Al Switching on the weighing indicator sks it dockets achid ctadhenes stabs tatis cured Puebt sala dueees raids gts 14 TAP LTO ess asae tae A ci ade ss eat oan aa ak an Pe tae aE een hs Orne a 14 7 3 Standard weighing procedure is aceon etaadutaa mahsind bamrremt ar sausou Dia he ate
4. m Warranty services are provided by AGRETO electronics GmbH only m The decision whether warranty applies is made exclusively by AGRETO electronics GMbH The warranty period starts when the end user is billed and ends 5 years after the invoice date A requirement for warranty is the presentation of the original invoice and compliance with all the points in this user manual Warranty doesn t apply to wear and tear nor to damages due to improper use negligence or accidents In case of a warranty claim transport costs are to be paid by the purchaser AGRETO electronics GmbH Seite 23 AGRETOtweepointsale ALO 11 Disposal When the product has reached end of life dispose of the product or parts thereof in an environmentally responsible manner with materials separated according to type scrap metal plastic waste etc do not add to household waste Detailed information can be found in Directive 2002 96 EG AGRETO electronics GmbH Seite 24 AGRETOtwweepointsale ALO 12 Declaration of conformity CE EC declaration of conformity For the following product AGRETO three point scale This confirms that the product meets the essential safety requirements as stipulated in the Council Directive on the approximation of the laws of the Member States relating to electromagnetic compatibility 2004 108 EG The evaluation of this product was carried out in accordance with the following standards EN 55022 1
5. the application A small deviation of a few degrees doesn t matter that much E Calibrate the scale Follow the instructions in this manual chapter 7 7 m Unsatisfactory weighing results can be caused by tensions in the scale s suspension The 3 attachment pins aren t Supported by ball bearings and even when balls and or hooks are used tensions build up in the system due to load changes These tensions dissipate while driving or moving This is the reason why the scale and implement must be moved twice during the calibration process It also explains why the scale weighs more accurately during movement than during standstill During static weighings for instance slowly filling a fertilizer spreader the displayed weight is usually lower than the true weight of the load because of tensions in the system Under higher loads the scale might not react smoothly to changes in weight When you have enough experience with your system you can add the missing weight If not you have to stop filling a bit earlier and clear the tensions in the system by moving after which the correct weight will be displayed Check without attached implement whether the scale displays the same weight on both sides Stand on the left and then the right side of the AGRETO electronics GmbH Seite 21 AGRETOtee pointscale ALO linkage If the difference is larger than 5 kg one of the load cells is malfunctioning or load cell suspension needs to be readjust
6. utenti 14 7 4 Weighing with tare THACHONG ciinsciecarisonnrvoundtaitec warrnaiccreveeUuatoaiecacmec una aunecaaeennbaniiies 15 7 5 Switching off the weighing indicator wrweriel alsa vcotei darrell aeescenat deca akisck dediaeabasohannetes 15 16 Setting eei vaca oaa hen aaa teeme a acacia teeta Gas Masel a ceca E A a O Saleen 16 Z COMITEMOM sarean Daan Ral aS A ymca heater Seah A teas bacal cate 16 7 8 Operation error IMESSAC SS ss wicsniiticeetus toner atecea dda isnk ncreratt elated Radke Seatac deat ath neal saliets 18 Tee OUD CIOL MISS SAG SS ait iaiia e E A A decor O E A E A 18 7410 Diagnosis eror mess ge Skaran i a E E E ER 19 8 Maintenance and cleaning ssss ssssesiisssskrristttt rent rere n nE EEEE Urtre ren ern rene mye ree ertaye 20 9 rouble SION eneo a a E AE NA A fia 21 T0 Waranty eenen e e EE ad tee Oa taut tae uate ER A E TEE T 23 11 MISSA rrea ule Starke a A AA 24 12 Declaration of COnfOrMity a pectintak esters hn Eli DOG Poe ited Errr Ped Bee ried Aa 25 To an ele A E A E souludads wma sunyena hte E E E meen em aE 26 AGRETO electronics GmbH Seite 2 AGRETO tee pointscale ALO 1 Introduction Thank you very much for choosing the AGRETO three point scale You have just purchased a robust tool for everyday use The AGRETO three point scale can only be employed as a checkweigher for internal use It s not allowed to be used for legal transactions Please read this manual carefully before putting the scale to use
7. 998 EN 60601 1 2 2007 NORM ISO 2332 This declaration is made for and on behalf of the manufacturer AGRETO electronics GmbH Pommersdorf 11 3820 Raabs Submitted by Anton Eder Managing director Pommersdorf 01 27 2014 Wy legally binding signature AGRETO electronics GmbH Seite 25 AGRETOtweepointscale ALO 13 Impressum All information specifications and images in this manual are correct according to the status in 2014 and subject to technical adjustments or changes in design Despite careful treatment and examination of the contents no warranty is made with respect to information in this user manual Any liability of the author is excluded Copyright 2014 AGRETO electronics GmbH AGRETO electronics GmbH Pommersdorf 11 A 3820 Raabs Tel 43 2846 620 60 Fax 43 2846 620 69 E mail office agreto com Internet www agreto com AGRETO electronics GmbH Seite 26
8. as temperature are too high EOCOO E0800 E0400 means that factory parameters have been lost and that EEPROM is malfunctioning 8 Maintenance and cleaning E Clean the AGRETO three point scale together with your implement High pressure cleaning must be done from a distance of at least 0 5 m E Store the machine in a dry and safe place E When you don t use the machine for a longer period treat it with a suitable anticorrosive agent AGRETO electronics GmbH Seite 20 9 AGRETO tee pointscale CLO Troubleshooting Proceed as follows when you have reason to believe the displayed weights are incorrect Make sure that there is no transfer of forces because a part of your implement touches the scale The implement can only be in contact with the scale through 3 attachment pins Make sure that the scale isn t attached too tightly on the side to your implement Check if there is still some space on both sides of the lower attachment points Consult chapter 6 of this manual Check whether the angle between scale and mounting brackets is exactly right The factory set calibration is only correct under an exact right angle and the position of the load doesn t influence the weighing result Consult chapter 6 of this manual Try to use the scale in a position that is as vertical as possible Use the top link brackets with either 130 mm or 160 mm hole spacing If this isn t possible the weighing indicator must be calibrated for
9. ause the stable scale is unstable 7 9 Setup error messages ENTRY There was an attempt to set a setting in SAFE Setup that can DENIED only be set in FULL Setup LIN PT There was an attempt to linearize to below the zero point LO PT TOO Adjustments points are too close to each other lt 2 CLOSE ae cannot be performed Use other usually higher RES Too little calibration values lt 100 were set LO RES Too many calibration values were set HIGH AGRETO electronics GmbH Seite 18 AGRETOthree pointscale aaa O O RB agreto SPAN Load cell signal is too weak for this setting LO a Load cell signal is too strong for this setting Zero point is below 2mV V 7 10 Diagnosis error messages E0001 Supply voltage too low E0002 Supply voltage too high E0010 Temperature too high low Check site 10 to 50 JC ambient E0020 Incorrect scale division Should be Change value between 100 and 30000 parts E0100 Settings have been lost Repeat settings E0200 Scale calibration has beenlost calibration has been lost New calibration calibration E2M E EE E E settings and scale calibration have AE settings and been lost calibration E0400 Factory parameters have been lost Service FATAL AGRETO electronics GmbH Seite 19 AGRETO tee pointscale ALO Error messages that start with E can be added together For instance E0012 E0010 E0002 means that supply voltage as well
10. d vertically or with a slight slant forward or backward the factory set calibration is correct and the scale is ready for direct use If this isn t possible the weighing indicator must be calibrated depending on how the scale is employed A calibration determines the scale s accuracy Perform the following steps only when necessary and with the greatest care Every new calibration replaces the previous calibration Proceed in the following manner m Place your vehicle on an even surface and put the empty implement in the operating position E Keep the weighing indicator s buttons on the far left and right pressed simultaneously until the calibration sequence starts m Wait until the word BUILD appears on the display AGRETO electronics GmbH Seite 16 AGRETO thee pointscale ALO Press the ZERO button twice The word CAL appears on the display Press the TARE button ZERO appears on the display Press the GROSS NET button The actual weight appears on the display Press the GROSS NET button Z inP appears on the display The zero point is determined confirmed by a sound 0 appears on the display Press the TARE button ZERO appears on the display m Press the TARE button SPAN appears on the display E Press the GROSS NET button twice The actual weight appears on the display Now load the scale with something of which you know the weight or fill your implement with a known amount of materials The we
11. ed If this is the case please contact the manufacturer mE Check with implement attached whether the scale shows the same weight when the load is in the front and then in the back of the implement If this isn t the case the imbalance must be offset by changing the angle of the top link mounting brackets ED If the scale displays a higher weight in the back you must shift the two mounting parts slightly upwards You do not have to remove the scale Loosen the 4 internal nuts of the mounting screws and tap the bottom of the sliding mounting parts with a rubber hammer If you can t slide them any further you have to remove the scale and insert the upper link pin in the next hole CFS O1e If the scale displays a higher weight in the front you must shift the two mounting parts slightly downwards You do not have to remove the scale Loosen the 4 internal nuts of the mounting screws and tap the top of the sliding mounting parts with a rubber hammer If you can t slide them any further you have to remove the scale and insert the upper link pin in the next hole OOO AGRETO electronics GmbH Seite 22 AGRETO tee pointscale CLO 10Warranty In addition to the legally required warranty the following warranty conditions apply to the AGRETO three point scale AGRETO electronics GmbH guarantees proper functioning and repairs or replaces all parts that exhibit material or manufacturing defects during the warranty period
12. g brackets must be in a perfect right angle relative to each other This will make sure that the load s position doesn t influence weighing accuracy AGRETO electronics GmbH Seite 10 AGRETOtee pointscale ALO Proceed as follows m Measure the necessary vertical distance on your implement between lower link pins and top link pins If there are several positions for your top link and or lower link choose a combination where the distance is between 50 and 65 cm E Determine which of the 4 holes on the three point scale s vertical top link brackets must be used for the distance you measured Loosen the 4 interior nuts of the adjustment screws set the measured distance and tighten the nuts again m The distance can still be readjusted after the implement is attached but first relieve any load from the scale Slightly loosen the nuts and use a rubber hammer to shift the brackets OOOO J ATTENTION The exact setting of mounting height is not only a prerequisite for accurate weighings When the angle is not exactly right the three point scale and or your implement could get damaged or deformed AGRETO electronics GmbH Seite 11 AGRETOtwee pointscale ALO 6 3 Mounting the three point scale You can choose whether you first want to mount the three point scale to the tractor or the implement When your implement has a rigid axle you must first mount the scale to the implement Of course the scale can be left m
13. ight should be as large as possible completely filling your implement would be best To prevent tensions in the implement and scale from influencing the calibration drive forwards and backwards again Press the GROSS NET button The most recently set calibration weight appears on the display Change the displayed number to the actual weight used for the calibration The number can be changed digit by digit which will flash Switch digits by using the GROSS NET button After the digit on the far right the digit on the left starts flashing again Change the flashing digit s number by pressing the PRINT button Press the TARE button S inP appears on the display The calibration is now carried out and confirmed with a sound The weight you entered is now flashing on the display m Press the TARE button to end the calibration function m To save the settings simultaneously press the Ein Aus and ZERO buttons until the indicator restarts To interrupt the calibration process at any point simply turn off the indicator AGRETO electronics GmbH Seite 17 AGRETOtWespointscale SS AIELO 7 8 Operation error messages U Underload Increase load or switch the scale off and back on again Taring attempt outside of the Reduce tare permitted range Zeroing attempt outside of the Reduce load permitted range STABLE A ZERO or TARE command Try again when the scale is ERROR can t be executed bec
14. ng down AGRETO electronics GmbH Seite 7 AGRETO tee pointscale ALO Load cells m 2 high resolution shear force load cells each at 5 000 kg 8mV V 350 Ohm Total nominal load 10 000 kg m 150 overload 300 breaking load m Protection class IP68 dust and waterproof E Operating temperature 35 up to 65 C m Temperature compensated 10 up to 40 C Weighing indicator m 6 digit LED backlit LCD display with 20 mm high digits 12 to 24 Volt power supply Operating temperature 10 up to 50 C Real time clock Tare through the push of a button zeroing the empty implement Shockproof and spraywaterproof Stabilized indicator for reading while driving OPTIONAL Two line weighing indicator with 30 20 mm high digits and special programming to display the spread rate per hectare AGRETO electronics GmbH Seite 8 AGRETO thee pointscale ALO Cabling Internal load cell connection with waterproof box IP67 3 5 m long weighing signal cable with special sheathing from the outlet on the front of the right frame part to the indicator Waterproof threaded plug connector IP68 2 m power supply cable with a flexible universal plug for cigarette lighter and standard sockets according to DIN EN ISO 4165 with integrated and replaceable fuse Accuracy 0 02 load cell accuracy 1 to 2 accuracy when operated properly in everyday conditions 5 kg weighing indicator resolution Readability during standstill or
15. ounted on the implement if it is only used for that implement E Try to use the three point scale in a position that is as vertical as possible Either use the brackets with 130 mm hole spacing or the brackets with 160 mm hole spacing If vertical mounting isn t possible the scale must be calibrated to obtain correct results Deviations are hardly noticeable when under 5 degrees in comparison to the vertical position 6 4 Connecting the weighing indicator E Position the weighing indicator in a suitable spot in the vehicle Connect the power supply cable Either use the provided cable or connect the indicator directly to the electric system The indicator can be run ona voltage between 12 and 24 Volt If during operation the power supply to the indicator is interrupted it will remember the scale s zero point but not a tare point that might have been set m Connect the weighing signal cable to the plug on the three point scale You could run the cable along the hydraulic tubes to prevent damage AGRETO electronics GmbH Seite 12 AGRETOtweepointsale ALO The weighing signal cable is assigned as follows Front view cable socket Front view cable plug on the scale on the connecting cable Number Description Function 1 EX Supply 2 EX Supply 3 Sl Signal 4 SI Signal 5 6 7 AGRETO electronics GmbH Seite 13 AaRETO three pointscaie ATO 7 Weighing indicator
16. smooth ride very good Readability during bumpy ride sufficient Deviation when load shifts front back left right none when operated properly Deviation on slopes hardly noticeable up to 5 E Deviation when inclined sidewards hardly noticeable up to 5 E Deviation when not attached vertically hardly noticeable up to 5 can be compensated through calibration AGRETO electronics GmbH Seite 9 AGRETO three pointscaie SR ATO 6 Getting started 6 1 Setting lower link distance m Measure the necessary horizontal distance between both lower link mounting points on your implement for instance a fertilizer soreader The standard dimension for Category Il is 87 cm but in practice it s between 86 and 88 cm E Set the required distance on your three point scale with the adjustment screws Use the exterior nuts of the adjustment screws on both sides of the three point scale to keep the construction symmetrical E Set the scale s width in such a way that there s a little space left between scale and implement so that the scale isn t under tension m When your implement has a rigid mounting axle you must completely remove the adjustment nuts on one side of the three point scale pull the scale apart during mounting and push it back together again 6 2 Setting mounting height A correct setting of the mounting height is of paramount importance for your scale s accuracy The horizontal and vertical top link mountin
17. the weighing indicator displays a stable value Read the weight This is the net weight without container If you want to weigh several goods in the same container you can put them on the scale one after the other As long as the NET symbol is displayed the previously calculated tare weight is subtracted and only the net weight is shown To switch from gross to net press the GROSS NET button m End the tare function by taking the load from the scale and press the TARE button again 7 5 Switching off the weighing indicator Keep the button on the far left pressed until the weighing indicator switches off AGRETO electronics GmbH Seite 15 AGRETOtee pointscale ALO 7 6 Settings The weighing indicator contains several adjustable parameters that influence the system s functioning Normally these parameters have been pre set correctly and only need to be changed in the case of specific requirements The parameters are described in the enclosed quick reference guide For use with the AGRETO three point scale the weighing indicator s following parameters differ from default settings BUILD CABLE 4 load cell connection with 4 cables BUILD CAP 6000 maximum load of the scale BUILD RES 5 weighing indicator resolution OPTION FILTER 4 maximum attenuation OPTION Z RANGE FULL enable zeroing up to maximum load CAL SPAN 2667 calibration value at 0 8 mV 7 7 Calibration When the AGRETO three point scale is operate
18. tillage implements can be attached Seed drills with normal sowing coulters are acceptable The weighing procedure can be performed during standstill or whilst driving Three point scales aren t officially calibratable and therefore not authorized to determine weights for legal transactions The scale is meant exclusively as a checkweigher for internal use AGRETO electronics GmbH Seite 4 AGRETOtWee pointscte AGO 4 Safety 4 1 Safety guidelines for the purchaser IMPORTANT Make sure that every person who works with the AGRETO three point scale for the first time has read and understood this user manual 42 Safety guidelines for operating and assembling personnel Appropriate equipment must be used when employing lifting machinery for transport Persons who are involved with mounting removing or setting up the three point scale must wear safety shoes Persons who are involved with mounting removing or setting up the three point scale must wear safety gloves CO gt AGRETO electronics GmbH Seite 5 AGRETO three pointscale LO During transport the scale or pallet can slip on the vehicle Transport and loading personnel must be instructed to securely attach loads Be aware of the risk of crushing between the three point scale s moving parts during mounting removing and setting up The scale must not be stored or used in a potentially explosive environment Be careful not to trip over par
19. ts or tools that could be lying around you AGRETO electronics GmbH Seite 6 5 AGRETO three point scae agreto Specifications Scale construction Steel construction with tubes and laser cut parts Internal load cells Roller supported mounting for implement attachment Designed for implements with a total weight of 6 000 kg Lower link attachment to the tractor Pins 28 mm 64 mm inner width for lower link with CAT II ball end CAT II hook and ball or CAT III hook and CAT Il reduction balls Lower link attachment to the implement Ball joint 28 4mm 51 mm width or a CAT Il Walterscheid quick coupling hook Lower link distance CAT Il standard 87 5 cm can be adjusted infinitely between 85 and 90 cm with set screws can be adjusted manually up to 105 cm for attachment to a rigid axle Top link attachment to the tractor Pins 25 4 mm 64 mm inner width for top links with CAT II ball joint or CAT II hook and ball E Top link attachment to the implement CAT II mounting brackets 26 mm E Distance lower link top link on the attachment infinitely adjustable between 48 and 68 cm Horizontal distance lower link pins implement pins lower link shifted backwards 160 mm 200 mm for hooks Horizontal distance top link pins implement pins top link shifted backwards 130 mm or 160 mm depending on the mounting brackets m Net weight approx 80 kg including pins m Dimensions 104x84x20 cm LxWxH lyi
Download Pdf Manuals
Related Search
Related Contents
H3C S5100-SI/EI Series Ethernet Switches Installation Manual 新機能および補足説明について(ソフトウェア Ver.1.90) 1 - Psn implantlink® Trust 5.1 Surround Speaker Set SP-6400M UK オートソープ 取扱説明書 Manual de Instruções Balanças NewClassic Modelos ML GT01-RS4-M Serial Multi-Drop Connection Unit User`s Manual MIMOSA CANALIZZABILE ダウンロード Copyright © All rights reserved.