1. Connect the hot and cold water hoses recognisable by the colour coding to the mains system Optionally the hot water connection may be connected to the hot water hose of the combi boiler Then remove the cap from the red hot water hose with the proper tool 7 Slide the connector on the red hose that comes from the boiler over the 3 in 1 tap connection until it can go no further b HOTSPOT er ENGLISH if A Or Fig 72 Attaching hose to 3 in1 tap 8 Secure the connector with the metal retaining clip supplied with the boiler Note the clip should neatly click around the connection housing Make sure the connection has been made properly by pulling carefully on the hose Fig 73 Attaching retaining clip 9 Connect the wire from the HotSpot 3 in 1 tap to the connector at the rear of the boiler hook downwards see fig 74 Fig 74 Connecting wire to boiler connector Refer to the HotSpot boiler installation and user manual for further details 3 in 1 tap 06038 rev 6 ENGLISH Dimensions 208 378 226 FT M Hole in working top 35 mm Dimensions Adrianna equals Alessio Fig 8 Dimensions 3 in 1 tap 06038 rev 6 ngtspor 3 in 1 tap Installed by Inventum B V P O Box 275 3990
2. The tap 5 5 Malfunctions 5 6 End of service life 5 INSTALLATION MANUAL 7 Installation 7 steps 1t m9 7 User manual images Fig 1 1 HotSpot Alessio 3 in 1 tap Fig 1 2 HotSpot Adrianna 3 in 1 tap Fig 3 1 Indicator lamp Fig 7 1 Installing the tap to work top Fig 7 2 Attaching hose to boiling water tap Fig 73 Installing the retaining clip Fig 7 4 Connecting wire to boiler connector 6 OBRNND ao ic by means of print photocopy microfilm or by any other means whatsoever without prior consent of Inventum B V This is also applies to the associated illustrations D HOTSPOT 3 in 1 tap 06038 rev 6 ENGLISH 3 1 Use of the manual This manual is intended as a reference for the end user and the installation technician Using this manual the HotSpot 3 in 1 tap may be installed safely Store this manual carefully you may need to use it in the future Inventum has prepared this manual with care However no rights may be derived from it In connection with continuous product innova tion Inventum reserves the right to change the specifications at all times and without prior notice 1 1 Application The tap should be connected to an Inventum HotSpot boiler and may only be used in com bination with an HotSpot boiler Any other or further use is not in accordance with the designated use Only install and use the tap in perfect condition 1 2 Warranty This tap has been manufactured with great car
3. gt inventum User and installation manual The Inventum HotSpot 3 in 1 tap With the purchase of HotSpot 3 in 1 tap you have bought a safe and reliable quality pro duct In combination with an HotSpot 4 or 8 liter Titanium boiler this boiling water tap provides you with boiling water at constant temperature as well as hot and cold tap water like every kitchen faucet The IntelliProtect system ensures Safety Certificate of conformity Inventum B V is an ISO 9001 certified company Inventum B V declares that the tap listed on the front is in accordance with 2006 95 EC Low voltage directive 2004 108 EC EMC guideline Harmonised standards EN 60335 1 EN 60335 2 21 EN 50082 1 Houten 29 June 2014 oN ALESSIO CHROME le ia C ouTLET art no 15402010 EAN LI 8716453008006 g ALESSIO PVD r Z C ouTLET eh art no 15402030 S EAN 8716453008020 Fig 1 1 The HotSpot Atessio 3 in 1 tap ADRIANNA CHROME U ouTLET art no 15402020 EAN 8716453008013 ADRIANNA PVD U ouTLET art no 15402040 EAN d gt 8716453008037 Fig 1 2 The HotSpot Aprianna 3 in 1 tap 2014 No part of this publication may be reproduced and or made pub ENGLISH CONTENTS USER MANUAL Certificate of conformity 2 1 Use of the manual 3 1 1 Application 3 1 2 Warranty 3 1 3 Liability 3 2 Scope of delivery 4 2 1 Packaging contents 4 3 Operation 4 4 Maintenance 5 4 1 Cleaning 5 4 2
4. GB Houten Kaagschip 25 3991 CS Houten The Netherlands Tel 31 0 30 274 84 84 Fax 31 0 30 274 84 85 E mail info inventum com P inventum www inventum com 07 2014 06038 rev 6
5. HotSpot 3 in 1 tap should only be repaired by a certified specialist Self repair can lead to dangerous situ ations Unauthorized repair will void the warranty If the power cable is damaged this should only be replaced by Inventum s technical service department in order to avoid dangerous situations 6 End of service life The HotSpot 3 in 1 tap contains no toxic or harmful substances and may be offered to your local refurbishment organisation The packaging materials are also entirely recyclable 3 in 1 tap b 7 Installation When installing the HotSpot the following must be complied with e Install the boiler according to the installa tion manual supplied with the boiler e Water pressure 1 5 bar e Maximum hot water temperature 80 C e When the water supply pressure exceeds 5 bar a pressure reducing device is re commended to ensure proper operation 1 Drill a hole maximum 35 mm into the work top at the desired location 2 Screw the two separate threaded ends into the tap housing from below The O ring must be installed between the working top and the tap 3 Slide the tap with the hose through the worktop from top to bottom The flat seat is optional 4 Slide the U shaped rubber packing and flat steel plate together with the nut over the threaded ends Fig 71 Fastening tap to work top 5 Place the nuts over the threaded ends and turn them tight under the worktop 6
6. In areas with water hardness above 14 DH Inventum states the use of a water softener with ion exchanger as a warranty condition DH German Hardness Service You should always contact your installer or supplier if you have problems with the instal lation and or the operation of the tap To order service parts please contact Inventum N B The failure of one or more components in no way justifies the replacement or return of the entire tap All relevant components can be obtained at short notice 1 3 Liability Neither Inventum B V nor your installer retai ler accept any liability for damage or bodily injury of any kind resulting from e failure to follow the instructions in this manual e carelessness during installation use main tenance and repair of the system e use notin accordance with the application e the use of components not supplied by the manufacturer e consequential damage due to leakage The HotSpot 3 in 1 taps only operate with an original HotSpot boiler See the user and installation manual of the boiler 3 in 1 tap b 4 2 Delivery 2 1 Packaging contents In addition to your HotSpot boiler you also have an HotSpot 3 in 1 tap in a separate pac kage This includes the following 1 An HotSpot 3 in 1 tap fitted with hose and control cable 2 A chromed slipring with O ring 3 Asteel pressure ring with rubber packing 4 Two nuts for mounting the tap 5 Auser and instal
7. boiler e Avoid large forces and loading of the tap outlet In connection with risk of burning ad justing the tap outlet during tapping is not recommended Holding the tap outlet just above the object to be filled is recommended this imits the cooling down of the water splashes and formation of steam Do not use plastic disposable cups to collect the boiling water These cups are often not resistant to the high temperature A cup glass or pan filled with water from the HotSpot will become very hot in a short time Bear this in mind use protection such as oven gloves or pot gloves You should always be careful with the boiling water from the tap Danger of scalding from direct skin contact Cups with a concave bottom must be carefully placed under the stream to prevent boiling water from running over the edge gt e po 3 in 1 tap 06038 rev 6 ENGLISH Have your HotSpot 3 in 1 tap descaled annually Chapter 4 Replacing Aera tor if you live in an area with water hardness higher than 12 DH 4 Maintenance Have your HotSpot 3 in 1 tap descaled annu ally if you live in an area with waterharness higher than 12 DH Make sure that when cleaning or performing maintenance the boiling water function of the faucet is not operated 4 1 Cleaning Both the boiler housing and the tap are easily cleaned with a soft cloth Do not use any aggressive or abrasive clean ing agents 4 2 The tap De
8. e and is warranted by Inventum for free of charge repair of all materials and or con struction faults Warranty provision The responsibility for the implementation of warranty rests primarily with the installer or supplier where the HotSpot 3 in 1 tap was purchased Therefore always consult your installer or supplier Warranty period e 10 years corrosion warranty on the tita nium inner tank without accessories 2 years on the other parts See www inventum com for more details Warranty conditions When claiming under the warranty the model of the tap should be mentioned e The purchase invoice indicating the date of purchase must be submitted e Immediately after purchase the warranty card must be completed and returned to Inventum B V The warranty applies only if e There are material and construction faults all this at the discretion of the manufacturer the tap is installed used and maintained according to this installation manual 06038 rev 6 ngtspot e no constructive changes or modifications have been made to the tap the defect is not a consequence of own fault negligence or improper use Warranty exclusions Labour costs Call out charges Shipping costs Administration costs Transport damage Secondary damage such as fire damage water damage or bodily injury In areas with a water hardness above 12 DH Inventum recommends the use of a filter with water softener
9. lation manual for the tap To avoid dangerous situations both the HotSpot boiler and the HotSpot 3 in 1 tap should be installed according to the accompanying installation instruc tions by a qualified specialist The installations instructions can be found at the back of this book Chapter 7 3 Operation The unique HotSpot 3 in 1 tap operates with an electronic control button in order to allow the water to flow from the tap The IntelliProtect system ensures safety by a completely safe low voltage The tap housing and the outlet will maintain a low temperature even if you tap water for a longer time This appliance is not intended for use by persons including children with physical mental and or visual impair ments or lack of knowledge unless supervised to that end by a competent person Fig 3 1 Indicator lamp b HOTSPOT eh ENGLISH In addition to the electronic control button there is an LED indicator lamp see fig 3 1 As soon as the electronic control button is pressed this LED lights up continually After a delay of 0 5 seconds the tap opens and the indicator LED flashes If the pan fill option is selected the indicator light steadily lits after 10 seconds to indicate that the water will run when the button is released The water stops flowing immediately if the push button is pressed again intelliProtect level 1 see for the settings of the protection the manual of the
10. pending on use and the hardness of the wa ter limescale may develop in the outlet of the tap If the water flow is less than 2 2 liters per minute you should clean the outlet or replace the mousseur These mousseurs are available at Inventum Replacement is simple Replacing the cartridge 1 Remove the small cap at the bottom of the control lever 2 Unscrew the adjustment screw in the control lever and remove it 3 Loosen the lock nut 4 Take out the cartridge and replace this with the new one 5 Put back all the components by carry ing out the above points in reverse order Replacing the mousseur in connection with scaling and or contamination 1 Unscrew the nut of the tap outlet if necessary with a cloth for better grip 2 Replace the mousseur or wash it clean with water 3 Put everything back in reverse order 06038 rev 6 n tspor 5 Malfunctions The HotSpot 3 in 1 tap is a Dutch quality product developed on the basis of years of experience and constructed using first class materials When a malfunction occurs you can resolve this on the basis of the table If the prescribed action does not have the desired effect disconnect the plug from the socket outlet and call your installer First note down the product name type number and serial number of your HotSpot boiler This information can be found on the back of the appliance in the user and installation manual of the boiler page 11 Your