Home
USER MANUAL - Handy Dryers
Contents
1. key supplied remove the 2 countersunk screws from the body of the unit N UV bulb e Pull the outer shell upwards gently to remove Take extra care to avoid scratching the shell 7 UV bulb Machine installation casing e Fix the unit directly to the wall using screws supplied Connections Live L Neutral N Earth Connector e o a fofo Pop out for rear NOU cable access Replace outer shell e Using the Allen key supplied tighten the 2 screws at the sides of the body Countersunk Allen key screws amp ROUTINE MAINTENANCE STERILL Place hands Turn hands Finally rub palms down to palms up hands together beneath the dryer and repeat to remove any backwards and forwards motion final dampness Move backwards and forwards in the air flow amp External maintenance Sanitisation outlet Clean with a soft cloth If the unit is very dirty use a soft dampened cloth with a neutral cleaning agent then polish with a soft dry cloth Only use neutral cleaning agents Do not use thinners acidic or alkaline toilet cleaners or nylon brushes they may damage the surface Sensing If using chemical cloths read instructions first a E Bi annual replacement of UV lamps Q NEVER look at the bulbs when in operation Ensure unit and power are switched off and remove the outer shell to access the lamp u
2. 50W Net weight 5 1kg STERILL amp PRE INSTALLATION PRECAUTIONS DO NOT install in the following places e Where the temperature can be below 10 C or above 40 C e Where the unit may come into direct contact with excessive water e If the unit will be in direct or strong sunlight e If there is a lot of condensation in the environment e If there are corrosive neutral or reductive gases present e 20m or more below or 2000m or higher than sea level Installation position The following diagram shows the recommended position e Ensure there is at least 150mm clear space below the machine either to the floor or other objects in the location e Itis recommended that a minimum distance of 100mm should be left clear to either side of the unit e Avoid locations where people or doors might damage the unit e Choose a completely flat wall surface to mount the unit onto 241mm r 170cm ER R 160cm Hole of junction box without shell E E Men 81cm E S amp E Y ite 3 3 a Miro 910m N Afo 1a 102cm oz 10 112cm 241mm f lt gt Floor amp PRE INSTALLATION PRECAUTIONS Connect the unit to power supply Embed a backbox in the installation location 1 switchbox no cover Cu 1060mm e If no backbox is used the power cord may mu prevent the unit from sitting flush against the wall Countersunk Remove the outer shell Scene e Using the Allen
3. Wall fixing template double sided 2 2 2 eee x1 Allen Key 2 2 cararte O x1 e Steno Unit orar ra sea eng ea nea x1 Warranty card oooccococc ee eee eee eee x1 air surface sanitisation STERILLO www sterillo com
4. l STERILLO INJURY MAY OCCUR IF MISUSED Prohibited Do not allow unit to get excessively wet amp Do not dismantle Follow instructions carefully Z e Do not open the front panel electric shock risk e Never look directly at the UV bulb when in operation e Do not allow children or adults to pull or hang on the machine e Place the unit away from direct water supplies e A suitably rated fused power supply is required e Ensure the correct power supply is used if more than 10 the unit may malfunction e The power must be turned off during installation and maintenance e Ensure the unit has a reliable earth connection e This hand dryer must be installed by a qualified electrician e If the power cord is damaged it must be replaced by the manufacturer its service agent or a qualified person e A residual current device RCD with a rated residual operating current not exceeding 30mA is recommended e Please use dedicated spur e Incase of malfunction switch off power immediately e Air filter must be installed Environmental Protection e Do not dispose of electrical waste with household waste please recycle in appropriate facilities Check with your Local Authority or retailer for recycling advice Voltage 240V Motor Brushed motor Phase Single phase Sensing distance 15 20cm Power 1400W Protection class IPX1 Air speed 60 105m s Dimensions 335 x 172 x 410mm Heating power 800 9
5. nit Remove lamp unit cover to reveal the dual bulb Carefully clear the unit of any dust using a soft brush Gently loosen the old lamp by holding the lamp holder in one hand and pulling the lamp upwards and away from the lamp holder Replace the dual lamp with a new one by inserting it into the lamp holder and pushing it downwards until it clicks into position Do not touch the new lamp with your bare hands Replace the cover 0 LED indicator lights LED lights showing through the top grills slowly fade on and off under normal operation If the LEDs change to red it means the lamp has failed and needs immediate replacement the Sterillo will still operate as a normal hand dryer however its sanitisation module will not be functioning until the lamp is replaced amp ELECTRICAL SCHEMATIC ED Components Baseplate Shell Countersunk screws UV bulb Allen key Heater E Electrical Schematic Fuse Power switch Lig Power o Indicator Temperature probe Sensing probe Temperature switches Heat switch Thermal fuse STERILLO 2 RAWPIUG u 00 00 ne ran daa dd A x8 30mm Wall SCreWS ooooocoocococccononcn x8 Splashback panel oooococcocccna en x1 e WaAIlSRICK GR os cnoasda be deb aie a ea Hae nn a x1 Instruction manual 0 0 0 0 00 x1
Download Pdf Manuals
Related Search
Related Contents
Manuale di istruzioni (5 lingue - contiene esploso, lista ricambi e Garage あんしん延長保証 サービス規程 家電保証 Philips Micro SD cards FM32MA35B Instructions pour le graphique d`utilisation des oligo Cisco Systems OL-8356-01 User's Manual C-HDM-COMPVGA User Guide pericolo - Graco Inc. Instrucciones para el uso Bombas manuales ZPH y magazine n°39 Copyright © All rights reserved.