ENGLISH LANGUAGE MANUAL
Contents
1. ENGLISH LANGUAGE MANUAL GIP Seattle WA U S A A ABOUT Switch is intended for condensation problem areas of a home such as near the shower or bath If condensation is a problem or is suspected to be a problem simply replace your existing fan switch with the fan switch For it to sense dew condensation the room will need to show visible signs of wetness attaching to surfaces such as steam on walls mirrors fixtures Visible steam in the air is not the problem the problem occurs when moisture in the air becomes too heavy and the air cannot support the moisture The moisture then moves to surfaces this is the dew point triggering the sensors The remarkable product is constantly checking the air for condensation At the right time It will turn ON your fan and run the fan to clear the room NOTE A good quality fan properly sized for the room is essential to the successful removal of moisture from any room It only detects condensation it cannot stop it It relies on a closed room and a quality fan to properly detect condensation and dry a room B INSTALLATION INSTRUCTIONS CAUTION 1 Use only a 120V AC 60Hz power supply connection 2 For indoor use only 3 Do not exceed maximum rating of the DewStop fan switch as indicated on the product label 4 Must be installed and used in accordance with your local electrical codes 5 If a bare copper or green ground connection is not available in the wall box
2. SWITCH new installation Install the the fan switch in a 3 inch deep single gang or multi gang electrical switch box OR replacement of existing switch remove existing wall plate and switch device being replaced 3 ATTACH POWER CABLE LIGHT CABLE AND FAN CABLE Attach 120v AC 60Hz 3 wire power Hot Neutral Ground inside the switch box with a minimum of 6 inch leads Attach fan three wire leads inside the switch box also with minimum 6 inch leads do the same for the light switch If an existing power connection is used in an existing switch box you must identify proper AC 120V Hot Neutral Ground are available 4 CONNECT WIRING General instructions for all configurations Make sure the switch box fan and switch are properly grounded See FIGURE 1 Make sure ground wire is securely fastened Tighten all ground screws or wire nuts securely Use the proper sized wire nut for 14 or 12 wire Make sure to strip back the copper wire 5 8 inch and twist wire and nut clockwise D MOUNT IN SWITCH BOX 1 Attach wire as shown in FIGURE 1 FAN SWITCH o 2 On El i 3 120V LINE AC E BLACK WHITE BLUE RED SWITCH WALL ENCLOSURE 2 I GROUND 2 Tuck wires into switch box and fasten to the switchbox with the two screws provide
3. contact a licensed electrician for installation oO 6 For use with permanently installed 120V AC powered fans only 7 Use only 14 or 12 copper wire connections WARNING Turn OFF circuit breaker or remove fuse s and test that power is OFF before wiring Wiring the fan switch live can cause serious risk of electrical shock and or damage the switch voiding the warranty FOR SAFETY THIS PRODUCT MUST BE INSTALLED IN A GROUNDED SWITCH BOX If you are unfamiliar with methods of installing electrical wiring secure the services of a qualified licensed electrician USE ONLY COPPER WIRE DO NOT use aluminum wire with this device IMPORTANT Read each step carefully and perform in sequence It will not work or will become damaged if wires are connected incorrectly To prevent damage connect exactly as shown in the installation diagrams otherwise warranty will be voided Prior to wiring straighten or clip ends of wire such that ends of each wire are straight if replacing with an existing switch Strip wire insulation at the end of each wire to expose 5 8 inch 16 mm of copper Where instructed to make a connection twist ends of stripped wires together and twist a proper connector clockwise until secure 2 C INSTALLATION STEPS 1 WARNING To avoid fire or risk of electrical shock turn OFF power at circuit breaker or disconnect fuse Test the power is OFF before you begin wiring 2 BEFORE YOU MOUNT THE FAN LIGHT
4. d See FIGURE 2 FIGURE 2 OCLLLEED yuueuune 3 Attach the switch plate See FIGURE 3 Corr gt FIGURE 3 E SWITCH FUNCTIONS e BLUE LED LIGHT CONDENSATION SENTRY LIGHT ON OFF FAN ON OFF S F TESTING 1 After you have completely installed the switch and attached the wall plate on the switch you can turn on the breaker to apply power WARNING If the breaker trips or the fuse blows STOP and call a qualified electrician to investigate the problem Turn the breaker OFF until the problem has been corrected 2 Press the light button to see the light turn ON press again to turn OFF Press the fan button to see the fan turn ON press again to turn OFF 3 With the fan off you can test the sensor by blowing into the sensor as if you were blowing on a mirror to steam it After blowing into the sensor with two or three puffs of breath wait 10 seconds and the fan will come ON automatically You will see the blue LED pulse slowly at the rate of one pulse every four seconds This shows you it is sensing condensation dew You can manually turn OFF the fan or allow the 30 minute timer to run 4 Sensor Override To turn off the sensor and LED and make it a manual switch only press both the ON and OFF buttons simultaneously and
5. he switch before sealing the openings Unscrew all box switches and pull them forward to allow access to the back of the electrical box Apply caulking into all openings in the electrical box even the very small ones Seal every opening and around electrical wires at their entering point Also seal the perimeter around the box between the wall board and the electrical box This will stop heat loss and allow switch to sense the room and not the drafts in the walls See FIGURE 4 AROUND EDGES Example APPLY CAULKING in these types of areas ELECTRICAL BOXES VARY IN DESIGN SEAL ANY OPENINGS FOUND H ONE YEAR LIMITED WARRANTY GTR Technologies Inc warrants to the original consumer purchaser of its products that such products will be free from defects in materials amp workmanship for a period of one year from the date of original purchase There are no other warranties express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose During this one year period GTR Technologies Inc will at its option repair or replace without charge any product or part which is found to be defective under normal use amp service This warranty does not extend to fluorescent lamp starters amp tubes This warranty does not cover a normal maintenance amp service or b any maintenance or repair faulty installation o
6. hold them down for 20 seconds To reactivate the sensor and LED features press and hold down both ON and OFF again for 20 seconds Now your switch is once again sensing for condensation NOTE When the fan has been turned ON by the manual button or the presence of condensation it will turn itself back to OFF after 30 minutes If it senses condensation the blue LED will pulse very slowly once every four seconds At all times you can manually turn OFF or ON the fan just as you would a common switch ELECTRICAL SHOCK WARNING This is an automatic ON device At no time should a person work on the fan light or any connected appliance without the electrical circuit breaker or fuse switched OFF It could turn ON the attached device by the unintended presence of condensation while the work is being performed Always disconnect the AC power before any work is done to any part of the circuit it is connected to If you do not understand this warning seek the services of a qualified licensed electrician Q G AIR DRAFTS IN ELECTRICAL BOX Older homes may experience air flowing drafts from the inside wall cavity into or out of the electrical box depending on the draft situation Sealing your electrical box openings is needed if you are experiencing any problems sensing condensation with switch The electrical box is easy to seal with standard painter s caulking and a caulking gun To begin you must DISCONNECT all electrical power to t
7. r installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express warranty Some areas do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you GTR Technologies Inc s obligation to repair or replace at GTR Technologies Inc s option shall be the purchaser s sole amp exclusive remedy under this warranty GTR Technologies Inc shall not be liable for incidental consequential or special damages arising out of or in connection with product use or performance Some areas do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you This warranty gives you specific legal rights amp you may also have other rights which vary from area to area This warranty supersedes all prior warranties To qualify for warranty service you must a notify GTR Technologies Inc at the address stated below or via our website at www DewStop com b give the model number amp part number identification amp c describe the nature or any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date 4 www com
Download Pdf Manuals
Related Search
Related Contents
Metra 99-7860 mounting kit accionador electromecánico para puertas seccionales Stop motion – mode d`emploi (vv 2013) o Cadre du concours ABUS TV8740 Programme - Ville de Genève BILLY GOAT MV650H Sauger Benutzerhandbuch PDF Nokia 3610 fold User Guide Installation instructions Ednet 84531 User ma n ua I - The Best Ideas For All Copyright © All rights reserved.