1. display the time and date by turns NI 2 01 ER 2out eyt Clock Adjusting e When the smartLAB indi is in Clock Mode press the START and MEM button at the same time the machine enters Manual Clock Adjusting mode the number of year will twinkle first Press START button continuously the numbers of month date hour and minute will twinkle in turn While the number is twinkling press MEM button to increase the corresponding number Keep on pressing the button MEM the number will increase fast e You can turn off your smartLAB indi by pressing START button when 13 the minute is twinkling then the time and date is confirmed e Your smartLAB indi will turn off automatically after 1 minute of no operation with the time and date unchanged e Once you change the batteries you will have to readjust clock Connecting the cuff to the monitor The cuff is attached to your smartLAB indi when it is packaged Should the cuff become unattached align the two plugs and four brackets of the cuff with the plug sockets and bracket sockets of the monitor and press the cuff to the monitor until the plugs and brackets are securely attached 14 Applying the cuff Place the cuff around a bare wrist 1 2cm above the wrist joint on the palm side of the wrist e While seated place the arm with the cuffed wrist in front of your body on a desk or table with the palm up If the cuff is correctly placed you
2. with date and time stamp Systolic and Diastolic be classified for your blood pressure respective Specifications 1 Model smartLAB indi 11 Heart Pulse rate range 40 180 min 2 Classification Internally powered type B 12 Environmental temperature for using 3 Device size 83 mm x 65 6mm x 32 2mm 5 C 40 C 4 Cuff size 300 mm x 70mm 13 Environmental humidity for using 90 5 Weight 130 g ohne Batterien 14 Environmental temperature for storage 6 Measuring method oscillometric automatic 20 C 55 C air inflation and measurement 15 Environmental humidity for storage 7 Memory volume 60 values with date and time 95 8 Batteries 2xAAA 16 Environmental pressure atmosphere 9 Blood pressure measuring range 0 295mmHg pressure 10 Measuring accuracy 3mmHg 17 Battery life Approx 1 months with 3 min usage per day Note AWN Stay quite calm and rest for 5 minutes before blood pressure measurement The cuff should be placed at the same level as your heart During measurement neither speak nor move your body and arm Measuring on same wrist for each measurement Please always relax a minimum of 3 to 5 minutes between measurement to allow the blood circulation in your arm to recover Remove the batteries if the monitor will not be used for a month or more to avoid damage of battery leakage This blood pressure monitor is designed for adults and should never be used on infants or young children Consult your ph
3. 1 08 2009 D30410 08 01 02 R2 31 smartLAB Fully automatic wrist cuff blood pressure monitor User Manual Please read this user manual thoroughly before first using the blood pressure monitor HMM Diagnostics GmbH m D 69221 Dossenheim Germany www hmm info Content I Introduction Normal blood pressure fluctuation II Your smartLAB indi Display amp functions Product description Specifications Note III Setup amp Operating procedures Battery loading Clock Mode Clock Adjusting Connecting the cuff to the monitor Applying the cuff Body posture during measurement Measuring Process oon 12 13 13 14 15 16 16 Displaying stored results Erasing results IV Miscellaneous Assessing high blood pressure for adults Knowledge on Blood Pressure Troubleshooting Maintenance Explanation of Symbols Warranty 18 19 20 21 27 29 30 30 I Introduction Thank you for using the smartLAB indi wrist cuff blood pressure monitor With this device you can easily control your blood pressure values and pulse rate and store the measured data With its colored Bi Classification LEDs all results on the meter can be classified according to their value Please read this manual thoroughly before first using your smartLAB indi wrist cuff blood pressure monitor Normal blood pressure fluctuation All physical activity excitement stress eating drinking smoking and many other activities or factors inclu
4. YELLOW Hypertension Stage 2 160 179 100 109 ORANGE RED Hypertension Stage 3 gt 180 gt 110 RED RED Hypertension Note It is not intended to provide a basis of any type of rush toward emergency conditions diagnosis based on the color scheme This color scheme is only meant to discriminate between the different levels of blood pressure 26 Additionally the Bi classification LED will display the corresponding colour respective for the Systolic and the Diastolic Example if the systolic value is 161 which is Stage 2 Hypertension the LED for the Systolic which is upper should display red And ifthe diastolic value is 89 which is High normal the LED for the Diastolic which is lo wer should display green Troubleshooting Problem Cause Remedy LCD shows low battery sym Battery power low exchange batteries bol LCD shows Er 0 Pressure system is instable be fore measurement LCD shows Er 1 Systolic pressure detect fail LCD shows Er 2 Diastolic pressure detect fail Don t move and try again 27 Problem Cause Remedy LCD shows Er 3 Pneumatic system is blocked oF cuff is too tight during n piace the cuff correctly and flation try again LCD shows Er 4 Pneumatic system leak or cuff is too loose during inflation LCD shows Er 5 Inflation above 300mmHg LCD shows Er 6 Over 3 minutes while pressu
5. You could obtain similar results by measuring your blood pressure for several days at the same time so called Basic Blood Pressure 23 Male Female Age systolic diastolic systolic diastolic 11 15 114 72 109 70 16 20 115 73 110 70 21 25 115 73 110 71 26 30 115 75 112 73 31 35 117 76 114 74 36 40 120 80 116 77 41 45 124 81 122 78 46 50 128 82 128 79 51 55 134 84 134 80 56 60 137 84 139 82 61 65 148 86 145 83 24 Hypertension Various cardiovascular or kidney diseases can cause hypertension Long term hypertension can also cause pathological changes in heart brain and kidney These changes can lead to hypertension complications which are often diagnosed or treated too late Low Blood Pressure There are two kinds of minimum pressure e If you always feel dizzy unsuitable in the chest and have difficulties in breathing or occurences of temporary myopia when standing up you might have a standing minimum pressure disease You should go to see a doctor e The original minimum pressure disease has no self symptoms besides low blood pressure To get rid of it you should pay more attention to nutrition and do more physical exercise 25 BD Classifica SBP DBP Color indicator Color changing tion mmHg mmHg area Optimal lt 120 lt 80 GREEN GREEN Normal 120 129 80 84 GREEN GREEN High 130 139 85 89 GREEN GREEN Stage 1 140 159 90 99 YELLOW
6. can read the LCD display e The cuff must be neither too tight nor too loose You should be able to insert one finger between the cuff and your wrist Body posture during measurement Sitting Measurement Recommended Position e Sit upright e Place palm upside in front of you on a flat surface such as a desk or table with your elbow resting on a chair or table e The cuff should be at the same level as your heart e Place your arm on the monitor s plastic case to aid maintaining a cor rect and still arm position Measuring Process e After applying the cuff and your body is in a comfortable position press the START button After a long beep your smartLAB indi will verify itself and LCD will twinkle automatically and the Bi classification LED will lighten ba AKI doo II o Da Dar Erg 16 e If it already has memory LCD will show the latest result If your smartLAB indi has not stored any memory the LCD will show six 0 The Bi classification LED will lighten with the colour that indicates the blood pressure classification of the result e Then your smartLAB indi inflates ey pa Ta Eg NI the cuff until sufficient pressure has UI WE built up for a measurement Then the EN 4 monitor slowly releases air from the LE Bal cuff and carries out the measurement 8637 99 1 3 58 AM Finally the blood pressure and pulse rate will be calculated and displayed o
7. card included in your product set Wear parts batteries etc are excluded from warranty 30 Manufacturer HMM Diagnostics GmbH Ca Friedrichstr 89 hm D 69221 Dossenheim Germany non mail info hmm info v hr www hmm info Weitere Informationen zu den smartLAB Produkten More information on our smartLAB products www smartlab org
8. ding taking a blood pressure measu rement will influence blood pressure value Because of this it is mostly unusual to obtain identical multiple blood pressure readings Blood pressure fluctuates continually day and night The highest value usually appears in the daytime and lowest one usually at midnight Typi cally the value begins to increase at around 3 00AM and reaches to high est level in the daytime while most people are awake and active Considering the above information it is recommended that you measure your blood pressure at approximately the same time each day Please always relax a minimum of 3 to 5 minutes between measurements to allow the blood circulation in your arm to recover Itis rare that you obtain identical blood pressure readings each time II Your smartLAB indi Display amp functions SYS Classification LCD LED systolic H START button diastolic MEM button pulse DIA Classification LED Set Contents 1 smartLAB indi Blood Pressure Monitor 1 User Manual 1 smartLAB Plastic Box 2 AAA batteries Product description Based on oscillometric method and silicon integrate pressure sensor tech nology blood pressure and heart rate can be measured automatically and non invasively The LCD display will show blood pressure pulse rate and irregular heart beat if any The most recent 60 measurements can be stored in the memory
9. eleted the LCD will show O for systolic diastolic and 00 for the numbers of memory heart rate By pressing the MEM or START the monitor will power off Ga 1 Erasing results ba When any result is displayed keep on ww KI pressing button MEM for three seconds DR and all results in current memory bank tab OO will be deleted after three beep By pressing the button MEM or START the monitor will turn off IV Miscellaneous Assessing high blood pressure for adults The following guidelines for assessing high blood pressure without regard to age or gender have been established by the World Health Organizati on WHO Please note that other factors e g diabetes obesity smoking 180 160 140 130 120 systolic mmHg severe hypertension mild hypertension high normal BP normal BP 80 85 90 100 110 diastolic mmHg etc need to be taken into con sideration Consult your physician for accurate assessment 20 Knowledge on Blood Pressure Your heart is just like a pump which causes the blood to circulate through all vessels As a result the blood pressure is the pressure on the wall of the blood vessel pressed by blood The output of gt o blood from the heart when it is a systole is called a systolic pressure The blood returning to the heart when it is a diastole is called diastolic pressure Blood pres
10. n the LCD screen The irregular heartbeat symbol if any and blood pressure classification indicator will twinkle The result will be automatically stored Porn u IM OR Im va E3 e After measurement your smartLAB indi will turn off automatically after 1 minute of no operation Alternatively you can press the START button to turn off the monitor manually e During measurement you can press the START button to turn off the monitor manually Displaying stored results e In clock mode press MEM button to display the stored results LCD will show the amount of results e A few seconds later the latest result will be displayed which is 01 for memory number It has irregular heartbeat indication if any and the indication of blood pressure classification The time of the measurement will also be displayed Continuously press the MEM button to scroll through the stored values 18 ar wu The Bi classification LED E3 HIKA U ia will also indicate the LAN US Ss Ba nm blood pressure we classification Fens j EOS IC teng 49 Press MEM button akn An a 208 ia again after the last memory the monitor will power off In the reviewing mode it will automatically power off after 1 minute of no use Alternatively you can press the START button to shut down the smartLAB indi e If no memory is stored or all memories have been d
11. re above 15 mmHg LCD shows Er7 EEPROM accessing error Measure again after 5 minu tes If the monitor is still ab LCD twinkling Device parameter check error normal please contact the lo cal distributor manufacturer LCD shows Er 9 MCU self verity error LCD shows Er A Span error LCD shows Er b EEPROM Backup error No response when you press any button BPM hang Incorrect operation Take out batteries for a while and then reinstall all batteries 28 Maintenance 1 Do not drop this monitor or subject it to strong impact 2 Avoid high temperature and solarization Do not immerse the monitor in water as this will result in damage to the monitor 3 If this monitor is stored near freezing allow it to acclimate to room temperature before use 4 Do not attempt to disassemble this monitor 5 If you do not use the monitor for a long time please remove the batteries 6 It is recommended to check the monitor performance every 2 years or after repair 29 Explanation of Symbols A Caution Please red user manual thoroughly e x Type B Applied Parts T Disposal Information Warranty HMM Diagnostics GmbH products need to fulfill high quality requirements Because of this reason HMM Diagnostics GmbH gives a 2 year warranty by purchasing this smartLAB product You can even extend the warranty from 2 to 5 years without extra pay when you register your product Please use the warranty
12. sure fluctuates continually day and night The highest value usually appears in the daytime and lowest one usu ally at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most people are awake and active For this reason it is recommended to measure your blood pressure each day at the same time 21 OPERATION BODY amp CIRCUMSTANCES Reason sytolic pressure diastolic pressure high low high low Drinking smoking e e Excitement or sporting e e seeing a doctor desire to urinate e e change of tem high e e perature low e e After bathing deep breathing or e e yawning Cuff placing tight e e loose e e Cuff position above the heart e below the heart e e 22 The blood pressure is influenced by a variety of different factors such as bodily circumstances or a wrong operation of the monitor Some people even get nervous when seeing a doctor and that will make their blood pres sure rise Single measurements can not indicate the whole blood level so you need not to be anxious for isolated higher or lower blood pressure results The most important thing is to master one s blood pressure trend through long term measurement Please talk to your doctor for useful judgement of your recorded values Average values of normal arterial blood pressure mmHg The following chart shows usual average values
13. ysician or other health care professionals before use on older children Blood pressure measurements determined by this monitor are equivalent to those obtained by a trained observer using the cuff stethoscope auscultation method within the limits prescribed by the American National Standard Electronic or automated sphygmomano meters Please avoid strong magnetism interference such as mobile telephone 10 microwave oven etc 10 If Irregular Heartbeat IHB brought by common arrhythmias is detected in the procedure of blood pressure measurement this signal will be displayed Oh Under this condition the smartLAB indi can keep function but the results may not be accurate it s suggested that you consult with your physician for accurate assessment 11 III Setup amp Operating procedures Battery loading e Open battery cover at the back of the monitor e Load two AAA size batteries Please pay attention to polarity Close the battery cover A When LCD shows battery symbol SI replace all batteries with new ones A Rechargeable batteries with a voltage of 1 2V are not suitable for this monitor A Remove the batteries if the monitor will not be used for a month or more to avoid relevant damage of battery leakage T The monitor the batteries and the cuff must be disposed of according to local regulations at the end of their usage 12 Clock Mode Once you install the battery two beep later the LCD will
Download Pdf Manuals
Related Search
Related Contents
Prime-Line M 6008 Instructions / Assembly Critères de classification hôtelière suisse Light Therapy Systems Greater well-being Manual Appendixes in pdf Iomega ScreenPlay Pro 320GB Multimedia Drive Final Report - Senior Design Pura(6.57 MB, PDF) Samsung BF1N4T015 Kullanıcı Klavuzu Manual Monitoriza Copyright © All rights reserved.