1. s Tv Le Es D620T E EE dimmerpack themann user manual MUSIC IS OUR PASSION Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 13 08 2015 ID 327887 Table of contents O On QU BU N Table of contents General 4 1 1 Further information 1 2 Notational conventions 6 1 3 Symbols and signal WOrdS sssccssccsssecssecsssccsnscesssccseccssscessecsescessseesasecsssceeseeesseecsneessnseesneeesseensee 6 Safety instructions same daria criara iria danada dad La 8 Featuresi Y ESY sabado 12 Installation and starting 2 13 Connections and operating 5 5 erre 2 16 Operation a E YA RA 20 Technical 1 31 Plug and connection 55 32 Protecting the 33 themann MUSIC IS OUR PASSION General information 1 General information
2. 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual themann MUSIC IS OUR PASSION General information Signal word Meaning DANGER This combination of symbol and signal word indicates an immediate dangerous situation that will result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage N Warning danger zone themann MUSIC IS OUR PASSION Safety instructions 2 Safety instructions Intended use themann MUSIC IS OUR PASSION This appliance is designed for professional use only and is intended to be used to control the brightness of connected spotlights Use the device only as described in this user manual Any other use or use under other operating conditions is considered to be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety Safety instru
3. to extend the life of the illuminants used Proceed as follows to adjust the maximum voltage 1 Open the menu Unit Setup Limit Ch 1 100 see menu overview 2 Confirm with the Menu button m The channel number display flashes 3 gt Select the desired channel with the navigation buttons A or V A Use the navigation button to change to the voltage value displayed value flashes 5 Adjust the value using the navigation buttons A or 6 Press the Menu button The display shows the confirmation prompt Save Changes 7 Confirm the prompt with Menu to save the new settings To discard the changes press the navigation button to return to the previous menu level 24 Setting the preheat Operating The preheat can be adjusted in a range from 0 15 This function is not available in Switch mode Off to DMX 64 On from DMX 64 Proceed as follows to adjust the preheat 1 2 gt Open the menu Unit Setup Preheat Ch1 0 see menu overview Confirm with the Menu button m The channel number display flashes Select the desired channel with the navigation buttons A or V Use the navigation button b to change to the preheat value The displayed value flashes Adjust the value using the navigation buttons A or Press the Menu button The display shows the confirmation prompt Save Changes Confirm the
4. This manual contains important instructions for the safe operation of the unit Read and follow the safety instructions and all other instructions Keep the manual for future reference Make sure that it is available to all those using the device If you sell the unit please make sure that the buyer also receives this manual Our products are subject to a process of continuous development Thus they are subject to change themann MUSIC IS OUR PASSION 1 1 Further information On our website www thomann de you will find lots of further information and details on the following points Download Keyword search Online guides Personal consultation Service This manual is also available as PDF file for you to download Use the search function in the electronic version to find the topics of interest for you quickly Our online guides provide detailed information on technical basics and terms For personal consultation please contact our technical hotline If you have any problems with the device the customer service will gladly assist you D620T General information 1 2 Notational conventions This manual uses the following notational conventions Letterings The letterings for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Displays Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF
5. prompt with Menu to save the new settings To discard the changes press the navigation button to return to the previous menu level themann MUSIC IS OUR PASSION 25 Operating Setting the DMX address themann MUSIC IS OUR PASSION Proceed as follows to set the DMX address da 44 re gt Open the menu Unit Setup DMX Addr Ch 1 01 see menu overview Confirm with the Menu button The channel number display flashes Select the desired channel with the navigation buttons A or V Use the navigation button b to change to the set DMX address The displayed value flashes Adjust the value using the navigation buttons A or Press the Menu button m display shows the confirmation prompt Save Changes Confirm the prompt with Menu to save the new settings To discard the changes press the navigation button to return to the previous menu level 26 Switch mode Operating When setting channel 1 the following channels are automatically addressed consec 11 utively This addressing may be adjusted as described above The unit is operational as soon as power is applied The activation is done automatically in Power on mode and in Manual mode using the Standby button Proceed as follows to adjust the Switch mode 1 Open the menu Unit Setup PowerOn see menu overview 2 Confirm with the Menu button current se
6. This chapter will help you select the right cables and plugs to connect your valuable equip ment so that a perfect light experience is guaranteed Please take our tips because especially in Sound amp Light caution is indicated Even if a plug fits into a socket the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX input Please refer to the drawing and table below for the pin assignment of a suitable XLR plug Protecting the environment 9 Protecting the environment Disposal of the packaging mate rial For the transport and protective packaging environmentally friendly materials have been chosen that can be supplied to normal recycling Ensure that plastic bags packaging etc are properly disposed of Do not just dispose of these materials with your normal household waste but make sure that they are collected for recycling Please follow the notes and markings on the packaging Disposal of your old device This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE Do not dispose with your normal household waste Dispose of this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country If in doubt consult your l
7. ctions Safety DANGER Danger for children Ensure that plastic bags packaging etc are disposed of properly and are not within reach of babies and young children Choking hazard Ensure that children do not detach any small parts e g knobs or the like from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where high voltages may be present Never remove any covers There are no user serviceable parts inside themann MUSIC IS OUR PASSION Safety instructions DANGER Hazardous voltage Hazardous voltage may be present at cable ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified elec trical personnel in volt free condition Failure to do so may result in electric shock and risk of fire and loss of life By all means you have to observe all electrical safety instructions applicable at the place of operation NOTICE Risk of fire Do not cover the device nor any ventilation slots Do not place the device near any direct heat source Keep the device away from naked flames themann MUSIC IS OUR PASSION 10 Safety instructions NOTICE Operating conditions This device has been designed for indoor use only To prevent damage n
8. ers the desired channels are being activated ON or deactivated OFF L1 L3 Voltage indicators of blocks L1 L3 The LEDs of the connected blocks light red as soon as mains power is applied to the device 1 6 Voltage indicators of channels 1 6 The LEDs of active channels light solid green during operation Display DMX IN DMX OUT DMX input DMX output D620T Connections and operating elements themann MUSIC IS OUR PASSION 18 Connections and operating elements Rear panel themann 19 Operating 6 Operating Turning on and off Once you connect the device to the power supply it is in standby mode The LEDs of the con nected blocks light red the display shows StandBy Mode Press StandBy Press Menu to switch from standby to normal operation Turn on the required channels via the associated circuit breakers LEDs of active channels light up green Use the navigation button to return to standby mode in order to switch off menu item StandBy Mode Press StandBy and disconnect the power plug from the 32 A CEE outlet themann MUSIC IS OUR PASSION 20 Operating DANGER Hazardous voltage Even in standby mode mains voltage is present on the outputs of the device and on the connected loads Hence there is danger to life and the risk of damage to property when connecting and disconnecting loads as well as during maintenance Di
9. ever expose the device to any liquid or moisture Avoid direct sunlight heavy dirt and strong vibrations NOTICE Power supply Before connecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire themann MUSIC IS OUR PASSION 1 Features 3 Features General features themann MUSIC IS OUR PASSION 12 6 dimmer channels Output 1 x screw terminal block Digital control system Control via DMX 512 Preheat dimmer curve and maximum voltage can be adjusted individually Indicators for temperature and operation Test function Intelligent cooling control large cooling ribs Single channel fuse 25 A Voltage supply via three phase screw terminal block 32 A Made in Europe Installation and starting up 4 Installation and starting up Unpack and carefully check that there is no transportation damage before using the unit Keep the equipment packaging To fully protect the device against vibration dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Establish all con
10. nections as long as the unit is switched off Use the shortest possible high quality cables for all connections themann MUSIC IS OUR PASSION 13 Installation and starting up The device is designed for mounting in 19 racks it occupies two rack units RU First connect the loads to the terminals on the back of the device Establish the DMX link to the controller Finally connect the device via the 3 phase screw terminal block to the power supply Connection options for blocks L1 L2 and L3 El one block per phase El one block to one phase two blocks to a second phases El all blocks to one phase O Regardless of the actual use all three blocks should always be connected C4 themann MUSIC IS OUR PASSION 14 Installation and starting up Connections in DMX mode Connect the DMX input of the device to the DMX output of a DMX controller or other DMX device Connect the output of the first DMX device to the input of the second and so on to form a series connection Make sure that the output of the last DMX device in the chain is ter minated by a resistor 110 O 72 W 44 8 2 j E EHH HE oe cito g R themann MUSIC IS OUR PASSION 15 Connections and operating elements 5 Connections and operating elements Front panel themann 16 Ch1 Ch6 Circuit breakers for channels 1 6 arranged in three blocks L1 L3 With the circuit break
11. ocal waste disposal facility themann MUSIC IS OUR PASSION 33 Notes themann 34 Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de
12. sconnect the power plug from the CEE mains socket before connecting and dis connecting loads as well as prior to maintenance to turn the unit volt free themann MUSIC IS OUR PASSION 21 Operating Menu overview StdBy gt Menu b Menu b AV P Unit Status Menu b 4 Going ir Bye A themann MUSIC IS OUR PASSION 22 Operating Setting the dimmer curve The device can be operated in dimmer mode Linear Sqrt Exp1 Exp2 or in Switch mode Off to DMX 64 On from DMX 64 Proceed as follows to adjust the dimmer curve 1 Open the menu Unit Setup Ch Curve see menu overview 2 Confirm with the Menu button The channel number display flashes 3 gt Select the desired channel with the navigation buttons A or V 4 Use the navigation button b to change to the curve value displayed value flashes 5 gt Select the desired setting with the navigation buttons A or 6 Press the Menu button The display shows the confirmation prompt Save Changes 7 Confirm the prompt with Menu to save the new settings To discard the changes press the navigation button to return to the previous menu level themann MUSIC IS OUR PASSION 23 Operating Setting the maximum voltage themann MUSIC IS OUR PASSION The device offers the possibility to limit the maximum voltage for each channel for example
13. tting appears on the display 3 gt Select the desired Switch on mode with the navigation buttons A or V 4 Press the Menu button The display shows the confirmation prompt Save Changes 5 Confirm the prompt with Menu to save the new settings To discard the changes press the navigation button lt to return to the previous menu level themann MUSIC IS OUR PASSION 27 Operating Test mode In Test mode you can check the individual channels Open the menu Test Ch 1 0 see menu overview Confirm with the Menu button da The channel number display flashes Select the desired channel with the navigation buttons A or V Change with the navigation buttons and lt between channel number and channel value Press the Menu button to exit Test mode CUL m The display shows the confirmation prompt Save Changes Confirm the prompt with Menu to save the changed settings e th mann MUSIC IS OUR PASSION 28 Channel value display Block temperature display Operating Proceed as follows to display the channel values 1 gt Open the menu Unit Setup Channel 1 68 see menu overview 2 Confirm with the Menu button The channel number display flashes 3 Select the desired channel with the navigation buttons A or V 4 Press the Menu button to exit the menu Open the menu Unit Status Unit Temp 34Deg to display the tempera
14. ture of the individual blocks see menu overview Select the desired block with the navigation buttons A or V Above a temperature of 45 C the internal fans will be switched on The fan power will be increased continuously up to 100 to a temperature of 65 C Above a temperature of 95 C the over temperature protection responses and turns the corresponding block off Then the display shows L Overheat Unit Overheated Once the temperature has dropped back below 80 C the block is automatically reconnected themann MUSIC IS OUR PASSION 29 Operating Checking DMX status To retrieve the DMX status open the menu Unit Status DMX Signal see menu overview When the signal is received correctly the display will show DMX Signal Ok On a faulty signal No DMX Signal appears In this case check the connecting cables and DMX settings on the device themann MUSIC IS OUR PASSION 30 7 Technical specifications Operating supply voltage AC 380 V 50 Hz Electrical connection Three phase connection max 32 A per phase Channel fuse 1 x circuit breaker per channel 25 A C characteristic Signal input DMX 512 via 3 pin XLR socket Outputs 1 x screw terminal block Dimensions W x H x D 483 mm x 90 mm x 390 mm Weight 10 8 kg D620T 31 Plug and connection assignment 8 Plug and connection assignment Introduction DMX connections themann MUSIC IS OUR PASSION 32
Download Pdf Manuals
Related Search
Related Contents
s6i_69r_hl0:Frontespizio 1.qxd Lumex Syatems LUMEX 6909A User's Manual CCTVカメラ設備機器仕様書(案)(平成27年3月) ロータリー MXR08 SCADALink 900-MB RTU / Radio Modem Manual Version 264 Issue TV manual - Digital UK Edital do Pregão Eletrônico nº 22-2012 Mod: DPA/BSV18 Gecko Pro Sleeve 15 LG LS980 E-Brochure Copyright © All rights reserved.