1. Operation of the 150kHz Broad Band and 75kHz Ocean Surveyor ADCPs on the USCGC Healy General Configuration The ADCPs consist of three components transducers mount in the bottom of the ship just forward of frame 63 near frame 60 deck units located in the gyro room next to the gym on deck level 2 and PC computers located in the Computer Lab The individual transducer wells are circular with removable lids and water tight electrical stuffing boxes To reduce ringing and acoustic interference from the ship an acoustic dampening material approximately 1 thick lines the inside of each well Acoustic windows consisting of approximately 2 thick SeaBeam Orange urethane are mounted flush with the bottom of the ship to protect the transducers from ice damage The wells are flooded by a propylene glycol Formula 2790 PG Green antifreeze fresh water mix maintained at a sufficient hydraulic head to keep sea water out in the event of a leak between the windows and the wells There is also an Applied Microsystems sound velocimeter Model SV2000 installed in the transducer well for the Broad Band 150kHz BB150 ADCP The cables from the transducers and velocimeter are led up two deck levels and forward to the deck units in the gyro room at bulkhead 44 Ship heading data is fed to the deck units through gyro synchro inputs Discussions with one of the ship s ETs Chief M McGuire and a representative from Sperry Mike Chappell indica
2. VmDas using the Options Edit menu After you have made changes save the options file before starting actual data collection Data collection is started by clicking on the blue right arrow in the upper left hand corner or by clicking the Control Go menu item Stopping data collection is accomplished by clicking the blue square or by clicking the Options Stop menu item When running VmDas shows the file name leader and data session number in the task bar at the top of the screen A number of visual real time data presentations are available while data is being collected These are controlled by the square buttons on either of the two lines immediately under the menu The button with the small R on it will cause the results from the individual pings to be shown The S button shows results from the short term averages while the L shows those from the long term average The next three buttons choose the display of velocities quality indicators and or a table of the data The buttons with CFS LDR BOT WTR and NAV bring up panels with configuration leader bottom track water track and navigation data respectively Choice of any of the display options has no effect on the data collection these are strictly for real time display purposes The figures can be fine tuned using the blue arrows or zoom in zoom out buttons Right clicking the mouse over any of the graphs brings up other choices for the displays It i
3. e The next three digits indicate the sequential session number the 6 digits after the _ constitute the file sequence number within each the session Each time VmDas is restarted the session sequence number is increased by one Note that VmDas will choose a session number that is as low as possible and will fill in gaps in the session numbers so it is important for orderly file management to let all the files for a cruise accumulate in the directory until the end of the cruise if possible The maximum size of the files is set in the options file typically 10 MB When a file reaches maximum size a new file is started with the same session number but with the file sequence number increased by one Different file types fill up faster than others so the file sequence numbers do not necessarily correspond to data taken within the same time window The file types and extensions generated by VmDas are the following ENR Raw binary ADCP data file which contains every ping ENS Binary ADCP data after the data has been preliminarily screened for backscatter and correlation ENX Binary ADCP data after screening and rotation to earth coordinate STA Binary ADCP ensemble data that has been averaged into short term average LTA Binary ADCP ensemble data that has been averaged into long term averages NIR Raw NMEA ASCII data from the primary navigation source N2R Raw NMEA ASCII data from the secondary navigation source if available and
4. nd includes the GGA message Attitudinal GPS data is also available to the ADCP system from the ship s single Ashtech GPS receiver mounted on the helicopter control officer s shack The helo shack is located over frame 114 approximately 40 8m aft of the ADCP transducers According to Chief McGuire and Mike Chappell from Sperry the Ashtech data for the PCs come directly from the Ashtech unit via an RS232 serial splitter box on the bridge from which cables are led to the PCs The refresh rate of the NMEA Ashtech data stream was adjusted by Chief McGuire to 1Hz during Healy cruise HY0201 and includes both the GGA message for position as well as the GPPAT message for Ashtech 3 D attitude During HY0201 both P Code and Ashtech data were sent to the PC for the OS75 but only one of the navigation streams was acquired by the BB150 s PC because that PC lacked enough serial ports A minimum of three serial ports are needed to connect to the ADCP deck unit plus the two navigation sources VmDas Data Acquisition Program There are several manuals supplied by RD Instruments describing the details of the BB150 and OS75 ADCPs and the operation of the VmDas data acquisition system Below is just a brief description of the operation of the VmDas VmDas is a Windows based program that operates on essentially any Windows 97 gt XP operating system While it is possible to set up and run the VmDas strictly using point and click choices in the options menu i
5. s also possible to show the short or long term averaged velocities as stick vectors on track plots However these only result in reasonable results if the ADCP s heading offset has been correctly entered in the txt file Not all types of presentation are available for each of the three types of data presented Setup of VmDas on the Healy The VmDas data acquisition PCs on the Healy are networked into the Science Data Network which supplies plenty of storage space for the voluminous files produced by the ADCPs A mapped drive on the network is thus the primary data file repository A backup subset of files is also recorded on the PC itself There is enough room on the present ADCP PCs to hold about 30 days of data before the directories need to be purged and they should be purged at least before each cruise The data files are currently stored on the server under separate directories for each instrument The files are stored under E cruisename for the BB150 and under F cruisename for the OS75 where cruisename should be a unique identifier The data files are also backed up on each instrument s PC in the directory C RDI cruisename There are 10 files generated each time VmDas starts anew ADCP session They are described in the VmDas manual pg 73 of the User s Manual if you need further information Briefly the files use the convention CRUISENAMEnnn_mmmmmm Ext where CRUISENAME would be something like HY0201 which uniquely identifies a cruis
6. t is recommended that previously saved and edited options files be used to control its operations as this minimizes the risk of missing essential in the setup The options or ini files are flat ASCII files typically saved in the VmDas subdirectory C Program Files RD Instruments VmDas The options file contains the path to an ADCP definitions or txt file which contains the commands that are actually sent to the deck unit by the PC The text files are also saved in the VmDas subdirectory The options file also contains directions about the running of VmDas itself items such as where the data is to be stored the short and long term averaging intervals scaling of screen plots and a long list of other items Both the txt and ini files can be edited with any simple editor Running a pre saved version of VmDas from the keyboard is quite simple Double click on the VmDas icon on the screen or start VmDas exe in the C Program Files RD Instruments V mDas subdirectory A blank VmDas screen will appear with a few menu options available Click on the file menu and highlight Collect Data This will open the data acquisition portion of the program and will probably show several empty plots and a data table The options ini file is chosen using the Options Load menu and choosing the correct options file for the ship s location and science needs You can view or edit items in the options file that effect the data processing and presentation by
7. te that the heading data supplied to the ADCPs can come from three possible sources There are two gyros and a single attitudinal GPS Ashtech unit that supply heading data to the ship s integrated bridge system These units are all inherently digital and the data from these units are converted to analog synchro outputs for the ADCPs through a D A converter Which of the three possible heading sources is sent to the ADCPs is controlled by a manual switch on the bridge Typically gyro 1 is used but above some latitude 800N the gyros produce poor data and the attitudinal GPS data source will be used in preference However there is no guarantee as to which data source is being used at any given time so it must be assumed that the choice is arbitrary The data source is clearly subject to change outside the control of the Healy s science group Given the construction communications and command needs on the Healy the only way to ensure a constant heading data source is to install a completely separate gyro system for science use However under normal conditions the arbitrariness of the heading source should not adversely effect the ADCP data since attitudinal GPS data output is available for post processing and can be used to correct the heading data to a single stable source Currently the velocimeter is not functional The BB150 ADCP deck unit has the capability to ingest sound velocity data directly but that is a poor option because the so
8. und velocity correction needs to be reviewed during post processing before it is applied A better choice is to have the sound velocity data recorded by the ship s Science Data Network Since the transducers are protected from changes in the sea water by the acoustic window and are immersed in an antifreeze water mixture the sound velocity is expected to be different from that in seawater and to vary rather slowly Thus the sound velocity corrections for the BB150 can mostly easily be addressed during post processing The deck units are connected to PCs in the computer lab through serial RS232 RS422 cables The PC s for both units run a Windows based program called VM DAS RD Instrument s new data acquisition system for vessel mounted ADCPs Briefly this program sends commands to the ADCP deck unit specifying the character of the acoustic pings to be sent by the ADCP and how the returning signal is to be processed before it is sent to the computer VM DAS then takes that data combines it with navigation data adds it to the data archive and displays a summary of the data on the screen together with ancillary information Navigation data on the Healy can come from either the dedicated bridge or science system There are P Code GPS units for both the bridge and the science components The P Code acquired by the unit in the Computer Lab is being sent directly to the ADCP PCs in NMEA format through RS232 serial lines at a refresh rate of 1 Hz a
9. which should include Ashtech heading data NMS Binary screened and averaged navigation data VMO This ASCII file is a copy of the ini options file that was used during the data collection LOG ASCII file containing a log of any errors the ADCP detected during the session