Contents

1. Aostan application tor new options to work In case of any IP conflicts there is opportunity to choose another free port The settings of RS485 converter to LAN are to be done in UDP field as button Options is to be pressed as a new window is being shown where are being indicated current IP ports speed network mask and Gateway IP All the previous mentioned settings could be changed by the user If an incorrect IP address is entered or it is forgotten when there could not be provided communication between Intiel Tracer Server and RS485 converter to LAN it is necessary to be restored the factory settings In order to restore to factory IP refer to LAN settings in description Building Management System a reference control module or RS485 converter to LAN Once after the factory IP address is restored then it 1s necessary the following IP address 192 168 0 016 to be entered in Intiel Tracer Server UDP Host In field Server Port port 8000 is entered as default as it is to be changed with another free one in case of conflict There could be chosen Bulgarian or English language concerning software operation interface It could be done in window Options General Options Users Device General Language C Default C Bulgarian To come in force all made changes the software and the device are to be restarted The device restart can be provided by means of stopping and starting 3 3
2. 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 9 7 Example application schemes Room 10 DOODODODODDDDDDGDDDGONDOOG Hcl tc To Next Module Central System heat cool Room 10 Room 1 Start Room il l I I I I I I I j T10 room 10 Room 5 Tl room 1 RS485 TTL Ct i US free To Next Module IN tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria ee T10 room 10 Tl room 1 10 2 Warranty The warranty period is 24 months following the purchase date of the unit or its installation by a qualified staff but not exceeding 28 months after the production date The warranty is extended to the malfunctions that occur during the warranty period and are result of the production reasons or defective used parts The warranty does not relate to malfunctions corresponding to not qualified installation activities directed to the product body interference not regular storage or transport The repairs during the warran eriod can be done after correct filling of the manujacturer warranty card Warranty Card Manufacturer INTIEL Building Management System BMS Product type Production number Production date Dealer s confirmation Purchase date Invoice number Dealer s name address and
3. application Intiel Tracer Server is installed In order to increase the safety of the access Authentication function is activated as default which checks out the authentication of the user name and password The user name and the password can be changed and the Authentication option could be deactivated with removing its tick in front of it The user can refer to the system administrator supervisor concerning the network settings of the local network The software is to be restarted in order the changes to come in force To enter the user application a user name and password are to be placed which are indicated in Intiel Tracer Server as depends on the level access those data could be only watched for level User or changed for level Super User The description bellow will give more information about the changes which could be done by means of Super User like adding new devices and removing existing ones as well changing of the settings gt User login Restat appScatos for new opmons to work Adding devices A user name and password are to be placed for level access Super User then button select is to be pressed in order to enter the basic window Device Controller and afterwards Devices The devices are connected to the system in a sequence way one after the other as after each one being added in field Device searching button Search is to be pressed When a new device is
4. INTEL THE ELECTRONICS ON YOUR SIDE Building Management System BMS User s Manual tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 1 Application The devise is designed for a control and monitoring of great number of temperatures Each module is equipped with 10 temperature inputs type Pt 1000 or independent contacts of a room thermostat as well 10 relay outputs concerning each temperature point and one output for sending a command to the central source of energy The device has ability for selecting a cooling or heating mode depends on customers needs as in heating mode it provides anti freezing protection of the heating system By means of the weekly programmer it could be kept different temperature levels during each day of the week within four time periods during a day To each module could be added another one as it could be fixed from 1 up to 255 sub networks as each one of them could have from 1 up to 255 modules When the connected devices are more than 32 then to each 32nd device is to be added an active recapitulation or connection block for RS485 The control of the device 1s provided by means of PC software as the connection between the device and the PC could be done through a local network or internet There is an option for a level access limitation which prevents incompetent intervention in the system A comprehensive description of t
5. Intiel Tracer Client this 1s a software for connection with the devices which operation requires first the start of Intiel Tracer Server and to be added user with user name and password with the relevant access rights After Intiel Tracer Client is being started window User login appears as during initial starting or changing the location of Intiel Tracer tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 4 Server it is necessary to fix connection settings Button Options is being selecting The language is to be selected by General in the same way like with Intiel Tracer Server For connection settings is to be selected Server When Intiel Tracer Client and Intiel Tracer Server are installed at same PC the default settings are to be remained same When Intiel Tracer Client and Intiel Tracer Server are installed at different PCs connected through local computer network of Server in the field Host is to be entered the IP address of the computer where Intiel Tracer Server is installed In case of remote access there is to be entered in Proxy Host the IP address of the PC which is a server of the local network where is located a PC with installed Intiel Tracer Client In field Host of Server is to be entered a real static IP address of the global internet network which is the IP address of the computer where the
6. al for module consists of hysteresis anti freezing functions and selection of the input signal Time periods each time period has an opportunity for assignation of operation time period and a temperature which is to be kept The temperature can be assigned within 10 up to 80 C with a step of 1 C The time periods can be assigned in hours and minutes as the hours are in the range of 0 24 with a step of 1 hour and the minutes within 10 50 with a step of 10minutes When the periods from and to are same for example hours from 24 to 24 and minutes from 0 to 0 it means the time period 1s prohibited In case of recovering of hour zones have same operation time periods the time period with less number is to be fulfilled with priority After the relevant changes for the day are being done then button Save is to be pressed for confirmation or Exit button for a denial tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 7 Hysteresis selection dt is within 2 10 C with a step of 1 C It shows the temperature with which it should be decreased after reaching the assignation during heating mode or increased during cooling mode in order to start the output again Anti freezing function it is active only in heating mode as it can be assigned within 0 10 C with a step of 1 C In case it is enabled the desired temperature w
7. be followed The test concerning 100 C is to be done with a resistor of 1385 Q as the instructions are to be followed again The tolerance of the resistors should not exceed 1 ipisona Thenmoniai 1 Setwrnrk 1 Device 1 Thermostat Module cotone Generaleptiote Calbration com Ill www intiel com By means of placing a tick Calibrate all inputs it could be calibrated in the same time and the ten module inputs For that purpose after the notice Please place a standard for 0 C to each inputs are to be connected resistors of 1O00Q for 0 C Respectively after the notice Please place a standard for 100 C to each inputs are to be connected resistors of 1385Q for 100 C The tolerance of the resistors should not exceed 1 In case of any doubt about the incorrect calibration procedure button Stop is to be pressed before termination of Stage 4 at the display After the procedure completion jumper CONS among pin 1 and 2 is to be placed figure 2 pg 3 5 Technical data Power supply 230V Nominal output 10W Nominal current trough the outputs 250V 3A Nominal current trough the inputs 0 83 mA Temperature sensors Pt1000 Humidity 0 80 Protection IP 20 6 Content of the set Building Management System 1 piece Converter RS485 to USB 1 piece CD with software 1 piece Sensors Pt1000 10 piece Tap for RJ45 1 piece Converter RS485 to LAN optional Desk control module optional tel 00359
8. being found out then a notice Found new devices appears In New device enumeration in field Subnet is to be placed 1 as in field Device 1 as button Add is to be pressed tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria The next device is being connected and Search button is to be pressed After appearing of the notice Found out new device in New device enumeration in field Subnet is to be placed 1 as in field Device respectively 2 and the button Add is to be pressed After each pressing of Add button at the upper part of the window from left to the right appears a list of Multi thermostat1 Multi thermostat2 etc The same is being repeated until all devices which are going to be monitored are being entered The number of the subnets can be from 1 up to 255 When the devices are more than 32 then to every 32 device are to be added an active recapitulation or RS485 connection block When the option Auto generated number is activated you have to be sure that the list from the upper part Multi thermostat I Multi thermostat 2 etc is complete and there are no missed devices because there could be dangerous of double named devices and the software will not be able to refer to the right one Change device number from this filed it could be changed all n
9. elect subnet it deletes the list with devices from the selected subnet e Select device it deletes a particular device from the list as assigned with number of subnet and device After selecting the desired option button Remove tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 6 Device controller in that window the relevant device can be selected for example Multi thermostat 1 as a new window appears which contents the following information Current day of the week and time Name of each thermostat from 1 up to 10 Inputs temperature or room thermostat shows the current temperature or contact state Indication ErrHi means the temperature sensor is missing or it is interrupted Indication ErrLo means there is a short circuit in the sensor Outputs shows the current state of each one of them Green means switched on as red switched off Thermostat settings button Options is to be pressed as a new setting window is being opened Field Name can be consisted of unspecified text up to 48 symbols The tick concerning Module enabled is to stop or permit the operation of the relevant thermostat Module settings there is a timer for every day of the week with four time periods mentioned with Option 1 up to Option 4 The general settings of the module are mentioned with Gener
10. he software is exposed in chapter Software bellow 2 Connection of the Building Management System 2 1 The power supply is to be connected to terminals 230V 2 2 Temperature sensors or contact thermostats are to be connected to terminals mentioned with T1 up to T10 2 3 Outputs relay independent contacts 3A 250V as outputs from 1 to 10 are switching and output Heating Cooling only switching on contact 2 4 PC communication input or input for previous module IN as it is to be used FTP or UTP cables with connectors RJ45 as the cable is to be done as for PC to HUB straight figure 1 It is to be connected to converter RS485 to USB in order to provide connection with PC 2 5 Output for communication with a next device Next module it could be used FTP or UTP cable with connectors RJ45 as the cable is to be done as PC to HUB straight figure 1 When the module is only one or last one a tap is to be placed which could be find out in the device set PC ST RAIGHT THRU HUB had ss 4 Re RX TT TX 7 CC CSE Figure 2 DI DI DI DI DI DI DI DIDIDI N 20 Output10 Output9 Output 8 Output 7 Output 6 Output 5 Output 4 Output 3 Output 2 Output 1 Heat Cool To Next USB Module IN tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 2 3 Software 3 1 Installation The software requires Windows XP or Windows Vista and 10 MB free di
11. ill be kept despite of the fact the module is not enabled It can be prohibited with removing the tick in front Enable Selection the type of the input signal there is opportunity for selection among temperature sensor Pt 1000 or independent contact of a room thermostat After the relevant changes are being done then button Save is to be pressed for confirmation or Exit button for a denial General options consists of timer settings and mode selection Timer Device 1 fix the current day of the week hour and minute of the module In case a tick is placed Set all active devices then the date and time will be fixed concerning all active devices stated in the list in the same time Mode Device 1 selection of operation mode with placing a tick for Heating or Cooling mode After the relevant changes are being done then button Save is to be pressed for confirmation or Exit button for a denial Calibration ATTENTION The calibration option is to be used only by authorized persons The devices are calibrated during the production and second calibration is to be done in case of certain problematic in measurement precision of the devices In case of calibration it 1s necessary jumper CONS figure 2 pg 3 to be removed A resistor of 10000 for temperature of 0 C is to be connected to the output which is to be calibrated as the instructions mentioned at the display are to
12. sk space Applications Intiel Tracer Client and Intiel Tracer Server are to be installed as well the drivers for RS485 to USB converter during its connection 3 2 Intiel Tracer Server manage all clients connected locally or remotely Initially or with a port changing the following announcement is being shown It could not be fix a connection with the hardware The button OK is to be pressed in order to go on The server can be maintained only by user with administrator level In User Login window 1s to be entered Name and Password admin which is the official user name and password for initial system entering After pressing Select button the system passes to next window Device controller It has to be selected menu File and then Options User login Options i Device General Users list User Password Level b admin admin Administrator Administrator ceco 1234 Super operator New users can be added or the existing ones edited in window Options A new user can be added by means of New button ar Unspecified text is to be added in fields Name Password and Names In field Level is to be selected Super operator or Operator Super operator level has access to all settings in software application Intiel Tracer Client Operator level is able only to monitor the current values and parameters without an opportuni
13. stamp Seller s name and signature Installation date Date Company address stamp Installer s name and signature tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 11
14. ty to make any changes Changing the existing User date could be provided by double click above the operator name Then a new window User is being opened where the desired changes can be made Any User can be erased as initially it is being selected and the button delete is being pressed The software is to be restarted in order the changes to come in force Window Options Device provides setting of connection type The default one is Serial port for connection by means of converter RS485 to USB between the Building tel 00359 596 333 66 Ill fax 00359 596 325 80 Ill info intiel com Ill www intiel com 9 Peter Beron Str Pomorie 8200 Bulgaria 3 Management System and the software Intiel Tracer Server The other possible connection type is UDP by means of converter RS485 to LAN Call the system administrator in case of problems When the connection type is Serial port it is necessary to be selected the virtual COM port to which the device is connected The rest settings are to remain as default ones A tick is to be placed to UDP in order to have UPD connection also the IP address of the device with which the information will be exchanged is to be entered RS485 charg device pt DER to LAN The converter RS485 to LAN ee has unspecified IP address 192 168 0 16 F For input Destination port is fixed 1024 and for output Source one 1025 Galiei IF Det a eari nea o E
15. umbers of subnets and devices First in filed From number the subnet and device numbers are to be entered which suppose to be changed as in field To number are to be placed the new numbers of subnet and device In case any device is being changed to subnet 0 and device 0 then it will be deleted automatically from the list Automatic addition from this field it could be automatically added in the list the existing with real number devices connected to the system There is opportunity for selection among the following options e Tn all subnets it scans all subnets from 1 up to 255 about devices The procedure takes time as it could be interrupted by means of pressing Stop button as only the devices which are being found will be added only e In select subnet it scans the relevant subnet for devices from 1 up to 255 The procedure can be interrupted by means of pressing Stop button as only the devices which are being found will be added only e Select device it adds only the selected device assigned with the number of the subnet and devices After selecting the desired option button Search and add is to be selected Clear list from this field can be deleted not currently used devices in case to avoid the window overburden with a large list of devices There 1s opportunity for selection among the following options e In all subnets it deletes all existing list e In s

Download Pdf Manuals

image

Related Search

Related Contents

知的活動における手書き入力の有効性 に関する定量的研究  Analyse et modélisation de la polysémie verbale dans une    Une solution bien dosée - technologie n°187 (link is  Henny Penny 581 User's Manual  MINISTERE DE L` AGRICULTURE ET DE LA PECHE MARITIME "V  Manual de instrucciones  FICHA TECNICA ECO-RUSTICO  Supermicro H8DM3-2  Samsung 700G7A-S01 用户手册 (Windows 8)  