Home

How to assembly of Link connector

image

Contents

1. Device for medical treatments device for safe etc 2 When used for the system by which higher reliability is demanded Use to vehicles control combustion control device etc Please be sure to turn off a system before installation or exchange work Please use an AnyWire system within the limits of the specification and the conditions that were set to this manual CAUTION Be sure not to turn on the 24V power before completing wiring and connecting in AnyWire System Use a regulated power supply of 24V DC Non regulated power supply may cause a trouble to the system Keep transmission cables and I O cables away from high voltage and power cables though the AnyWire System has high noise margin Be careful not to allow metal bits into the unit the connectors or the terminal blocks especially when wiring Mis wiring may cause failure Consider the length and installation of cable wiring to keep connectors and cables from disconnecting or excessive distortion Never solder the stranded wire to be connected with the terminal block otherwise causing a defective contact In case of long cable length of power line along the transmission lines large voltage drops will occur and may cause voltage shortage for the distant Slave Units In that circumstance connect the local power supply units so that the prescribed voltage is secured at each local Slave Unit i Be careful of the following items about installation en
2. Naywite Anywire Corporation AnyWire DB A40 series AnyWire Bitty series AnyWir OpenTerminal series Link Connector Insulation Displacement Method of Flat Cable Additional version First version 07 November 2006 UMA 0A Caution Items The cautions to this manual 1 This manual should be sends to last user Please perform operation of this product after often reading this manual and understanding the contents 2 This manual explains the functional details included in this product and does not guarantee Suiting a visitor s specific purpose 3 Reproducing and reproducing some or of this device without notice refuses 4 It may change without a preliminary announcement about the contents of this manual in the future Warnings Warning shows the contents a possibility of getting death or seriously injured is assumed to be when handling is mistaken CAUTION Caution indicates that the failure to follow this instruction can result in minor injury or property damage In order to use it safely An AnyWire system is not a thing having a control function aimed for safe security When as follows while having care special about safety measures which had a margin to rating and a function and to be used such as a way and fail safe carried out please consult to our company 1 The use for which high safety is needed The use it is predicted to be to have big influence to a human life or property
3. displacement connector 4 3 5 Connection Three connection types are possible if coupling with insulation displacement intermediate insulation displacement cable and the end cable insulation displacement Addition T type branch H type branch T type branch example 5 1 6 AnyWire System Warranty gt Warranty period The warranty of the Product delivered shall continue effective for one 1 year after the delivery thereof to a location as designated by the original owner gt Scope of warranty Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in accordance with specifications described in this User s Manual The Company shall replace or repair the defect without charge except when it arises out of 1 The misuse or abuse of the Product by the owner 2 Other cause than the Product delivered 3 The unauthorized alternation or repair of the Product by any person other than the Company s personnel 4 Any unusual force of nature disasters and other causes beyond the Company s control The word warranty as used herein means the warranty applicable to the delivered product alone and the Company is not liable for consequential or incidental damages induced by any malfunction 7 Change History Date 7 1 Anywire Corporation URL http www anywire jp Headquarters West Japan Office 8 1 Shimoinden Inouchi Nagaokakyo shi Kyoto 6
4. 17 0813 JAPAN TEL 81 75 956 1611 FAX 81 75 956 1613 E East Japan Office 47 Kandakonya cho Chiyoda ku Tokyo 101 0035 JAPAN TEL 81 3 5209 5711 FAX 81 3 5209 5713 TEL 81 52 452 8711 FAX 81 52 452 8713 E Kyoto Factory 19 2 Umatate Kamiueno cho Muko shi Kyoto 617 0006 JAPAN TEL 81 75 922 1911 FAX 81 75 922 1913
5. ERO AGH Connector body P IRIART Connector body Electric pole part IARI ZAIN BMBOASDZN Hole inserted electric pole 5 Fasten the status of 4 using dedicated tools Suzuden Corp L Tool N Make sure that four large hooks attach into the connector cover holes properly with a snapping noise 6 Completed when failure or changing layout you cannot reuse dismounted insulation displacement connector 3 3 4 Insulation Displacement to the Intermediate of Flat Cable Signal assigned to flat cable is same as previous section 1 Prepare the connector cover Cut the top of end surface parts by nippers or like device CUT End surface parts 2 Close the connector cover when flat cable insert to connector cover Small Hook 4 1 3 Check that a small hook insert properly 4 Insert connector body to connector cover of 3 Four electrical poles from connector body should insert into four holes on connector cover Connector body hole Se a Ti ARISAN am TAN Large hook Connector body IRIART Connector body Electric pole part IKRDAAIN Connector cover ERDAS Hole inserted electric pole 4 2 5 Fasten the status of 4 using dedicated tools Suzuden Corp L Tool N Make sure that four large hooks attach into the connector cover holes properly with a Snapping noise 6 Completed when failure or changing layout you cannot reuse dismounted insulation
6. ng as shown in this manual Please refer to this manual as an additional manual separate from pliers insulation displacement work a standard work method introduced in AnyWire Technical manual or laying Manual 2 Subject to combination Flat cable FK4 075 100 AnyWire model Link Connector LP4 BK 10P AnyWire model 38104 0018 000FL 3M model Do not use other than above combination AAN caution Otherwise connection faire may occur Please confirm specifications and select adaptable link connector for cabtyre before you use For more details refer to the 3Mwebsite 2 1 3 Insulation Displacement to Flat Cable Terminal Depending on AnyWire standard identification color signals of flat cable are assigned as shown in the table below Signal DN Bitty OpenTerminal DP Bitty OpenTerminal ov 24V Name G AnyWire DB A40 D AnyWire DB A40 Une color Bak Red White Green This coloration and signal relations may be the basis device connection 1 Prepare the connector cover 2 Close the connector cover when flat cover inserted to the connector cover Small Hook Hinji Black 3 1 3 Check the end surface of cable insert connector cover and attach a small hook properly 4 Insert connector body to connector cover of 3 Four electrical poles from connector body should insert into four holes on connector cover Connector body hole Ba A Large hook Ztaxp T
7. vironment No exposing directly to the sunlight and ambient temperature is 0 to 55 C Operating relative humidity is 10 to 90 and no dew condensation by sudden temperature change No corrosive or inflammable gases No direct vibration or impact Fasten terminal screws securely to avoid malfunction In case of storage of the product keep away from high temperature and high humidity Storage temperature is 20 to 75 C When the emergency stop circuit or the interlock circuit for safety is arranged provide these circuits outside the AnyWire System Contents NO OB WS DBS Introduction Subject to combination Insulation Displacement to Flat Cable Terminal Insulation Displacement to the Intermediate of Flat Cable Connection AnyWire System Warranty Change History 1 Introduction Link Connector is an IDC Insulation displacement contact type connector for use as adding or branching connections with the same connector combinations for a dedicated flat type connector Basically IDC pliers must be used with this connector According to 3M catalog However dedicated tools for Insulation displacement work can be purchased instead of pliers The finish coupling of housing or contact may be different depending on the worker s experience or the number of processing when using pliers For safety we recommend that dedicated tools be used if user is inexperienced even if performing multiple processi

Download Pdf Manuals

image

Related Search

Related Contents

- Media  材リックします。  ROTHENBERGER Worldwide www.rothenberger.com  prb tradiclair 190 l prbtradiclair 190 l sous  3/2014 „Schatz – die Stromrechnung ist da!“  - Clarion    WÄRME- UNTERBETT  Samsung SCX-4833FD  

Copyright © All rights reserved.
Failed to retrieve file