Home
Fingerprint Safe /Lock module Smack Bio S50 User`s manual
Contents
1. Pin2 DC IN 6 5V alkaline battery CON6 Communication Port RS232 Pinl GND 4PIN Pin2 Rs232 Tx Rs232 Transmitter 2 0 Interval Pin3 Rs232 Rx Rs232 Receiver Pin4 VCC CONS Outside switch Outside switch Pinl VCC 5V Output and indicator Pin2 LED G Green LED Output LED Pin3 LED R Red LED Output Pind GND 2 0 interval Pin5 Reset Reset switch connecting GND Pin6 POWERKEY Start switch connecting GND 29 Fingerprint Safe Lock Module User s Manual CON7 Inside switch SMACK Pinl GND Inside Pin2 Enroll KEY Enrollment key connecting GND switch Pin3 Delete KEY Deletion Key connecting GND delete only users 4PIN Pin4 ALL Delete 2 interval All delete key connecting GND Delete all users including managers CON4 Motor driver output Motor Pinl Motor0 Motor driver output 0 control output OPIN Pin2 Motor Motor driver output 1 2 0 Interval CONI Door state and Open Closing Control Control Door state 5PIN 2 0 Interval Pinl Close processing Detect whether door was closed already and stop switch the motor Pin2 Close Swtichl When close the door Close switch 1 and 2 is connected Then mechanical executant part starts the motor to closing direction Pin3 Close Switch2 When close the door Close switch 1 and 2 is connected Then mechanic
2. part After the Identification is successful control motor runs deasil motor will stop running when switch signal are input or there is no switch signal within 5 seconds Motor begins running retrorse when door situation switch inputs signal Motor stop running when shutdown switch signal are input Fingerprint Safe Lock Module User s Manual SMACK Opening the safe box as usual operation flow as follows Press start key green LED flickers Re input finger Identification fails Buzzer emits long whistles 3 times and green LED flickers after red LED flickers Identify successful Success Identify success Three short whistles Green LED is on for a long time times and unlock 2 Enrolling a fingerprint The safe box can contain 50 fingerprints it separate manager and user according to enroll order the first three fingerprints are managers and others are users fingerprints At first press the start button and green LED flickers then press the enroll button after red LED flicker one second it will be off green LED flickers continually it is possible to enroll then user can put one finger on 9 Fingerprint Safe Lock Module User s Manual SMACK sensor flatwise The user should press one finger three times per an enrollment After the first time to press the finger green LED flickers and buzzer emits a sound of short whistling After this press the same finger second time then gree
3. Fingerprint Safe Lock module smack Bio S50 User s manual BeiJing Smackbio Technology Co Ltd Fingerprint Safe Lock Module User s Manual SMACK Table of Contents Table Of Contents cccccssicsceccscssccscescocessesseteccocscsctsssssecescdsvecssssessessscscectssdessesseccseousesavsessccocessaceeeed L WS PO juriste Chapter 1 Technical specification eerie eee eene eese en ee en atenta aetas tasa tosta seta seta aan 2 Chapter 2 FUNCTIONS R 3 TE One finger Tent ati mee H Chapter 3 Function buttons and Notice csccccccssscssssssscssscsssssssenssesssessssssesssssscsseesees 5 1 Function DUttons cccccccssccesscecssccssscecssecesscecseceseeecssecseesessecueeecseceseeecsueceseeecsaeeseaeecaesesseeecueceeeeecsaeeneetess 5 2 Indicator LED and buzzer beep notice ee eeescseesceseeeceseeeeesecseesecsevecenaeeeceaecaeesecaeeeesnaveresaeeeeeaecaeeeeeaeeates 5 Chapter 4 Using details and flow cssccsssssscssscssscsssscsssscsssssssssssssssssssssssssesesssssesssesses 7 1 Unlocking safe BOX 20 ecceccesecsseesseesseeseeeecesecesecsecaecsaecsaecseecaeesaecseecaeessesesessaeseesaeenseceaeecseecaeeeaeeeeeeneeeereees 7 2 Enrolling a fingerprints scssi siipien rne T ds cde He HE ERE E FER EUER E RE RH 9 3 Delete unperpritibx o voeetensEaS QUEEN ESI LM IEEE 12 A Insttalization 2 5 cnr etr
4. K It can enrolled more fingerprints continuously after one user successful enroll green LED flickers it can enroll the next user 3 Delete fingerprint Delete button is used to delete user s fingerprints the operation flow as follows Press Start button and delete button then red LED and green LED flicker for one second buzzer emits three long sound of whistle now deleting and then buzzer emits three short sound of whistle it means that deleting users fingerprints are successful After having done above operations all users fingerprints data are deleted Deleting fingerprints data operation flow as follows Press Start button Press Delete button Red and Green LEDs are on at the same time If deletion is successful buzzer emits the long sound whistling three times and then the short sound whistling three times Fingerprint Safe Lock Module User s Manual SMACK If you want to delete the manager s fingerprint use the initialization button 4 Initialization First pressing the start button and then press the initialization button Buzzer emits long whistling three times Now initializing and short whistling three times continuously after short beep initialization will be completed and all the fingerprints data are deleted Please do not use this function recommend you to conceal installing the initialization button Fingerprint Safe Lo
5. al executant part starts the motor to closing direction Pin4 Open Processing Detect whether door was opened already and stop switch the motor Pin5 GND 2 Dip switch for one and two fingerprints mode User can change the mode of the identification by Dip switch 2 4 3 2 nu Dip switch 2 High One fingerprint mode Switch of the identifi cation mode Low Two fingerprint mode 30
6. at it can enroll or delete fingerprints data after be successful identified by manager When the red LED flickers once and then green LED flickers continually It Fingerprint Safe Lock Module User s Manual SMACK means that user can enroll or delete fingerprints data without identification by manager 2 Buzzer notice When the buzzer emits sounds of three short whistling it means that finger enrollment or identification is successful When the buzzer emits sounds of three long whistling it means that finger enrollment or identification fails After buzzer emit sound of three long whistling and then emit three short whistling it means that delete fingerprint When the buzzer emits sound of one long whistling it means it has the enrolled fingerprint already Fingerprint Safe Lock Module User s Manual SMACK Chapter 6 Using flow details 1 Unlocking the safe 1 The first unlocking there is no enrolled fingerprint in safe box Leaving factory Safe box has no any fingerprint data if user presses any one of Fingers the safe box will be unlocked When you want to use the safe box first you should press start button then green LED flickers please put the finger on sensor User can put any one of the fingers on the sensor trying to press the finger and the safe box will be unlocked when green LED was off 2 Normal unlocking the safe have already enrolled fingerprints Press start button and then green LED flickers Put
7. ce When the buzzer emits sound of three short whistling it means that enrolling a fingerprint or identification is successful When the buzzer emits sound of three long whistling it means that enrolling a fingerprint or identification failed After buzzer emit sound of three long whistling and then emit three short whistling it means that fingerprints are deleted When the buzzer emits sound of one long whistling it means that the fingerprint is enrolled already Fingerprint Safe Lock Module User s Manual SMACK Chapter 4 Using details and flow In the case of normal using when the safe box is given to the customers It must have already enrolled the manager s three fingerprints and user s one fingerprint at least and then use for customers in the case of less than manager s three fingerprints enrollment and user s one fingerprint enrollment any user could unlock the safe and enroll operations When give the safe to customer to use Having enrolled manager s three fingerprints user can enroll fingerprint unlock and management operations such as deletion Manager can enroll fingerprints unlock and management operation at any time Note 1 The fist three enrolled fingerprints are manager s one and after manager s fingerprints are enrolled the next enrolled fingerprints are user s fingerprints 2 Delete function only delete user s fingerprints if you want to delete manager s fingerprints the initiali
8. ck Module User s Manual SMACK III Two Fingerprints Identification Note As for safe box of two fingerprint mode to be unlocked it will be use when enrolling manager s three fingerprints and at least one user s fingerprint The safe will be unlocked only when one of the manager s fingerprints and one of user s fingerprints are identified 1 It can be unlocked if both any one of the manager s and any one of the user s are identified 2 Enrollment and deletion operation will be possible only after manager s successful identification Two fingers mode is only effective in opening and there is no effective in others Other using method is the same as one finger to unlock mode Fingerprint Safe Lock Module User s Manual SMACK Chapter 5 Function buttons and Notice 1 Function buttons 1 Outside function buttons Start button used for system start 2 Inside function buttons Enroll buttons used for enrolling fingerprints Delete buttons used for delete user s fingerprints Initialization button used for delete all fingerprints including manager s fingerprints 2 Indicator LED and buzzer notice 1 Indicator LED D Normal using When the green LED flickers please press the finger When the green LED is on for 0 5second identification success When the red LED is on for 0 5second identification failed 2 Enroll and delete fingerprints data When red and green LED flicker at the same time it means th
9. e cte trece t cuted cussed d ee esr eoH ek eC Ee FELD EUER BERE E DE Er LER E Eger s 13 Chapter 5 Function buttons and Notice eee eee eee eene eee etes eene tnnt ta setas ta sensn no 15 1 Function Buttons NER TR NE 15 2 Indicator LED and buzzer notice essen ener nenn ete rn eser EEEE Ee Eeunenn eeen tete n nene ne 15 Chapter 6 Using flow details 4 ceres eerie eee ecce eese eee seen ee en netta s tna setas esten seen naso 17 1 Unlocking the Safe noceret ere EE e HE HH REEF PEERS RE ERE EERE 17 2 Enrolling fingerprints essen enne enne ennt testes ts stets trennen erret 20 3 Delete fu Berpritits o e e ertet Eco teen v esa ure iut iter sete a ets deesber erus eet aed hs 25 A InitializatiOn cce oett ter EE EEUU ERE ERE HER TREE LESE ERE CE ETE EE EE EIE EE RC EE CSS 28 IV Appendix A 29 Fingerprint Safe Lock Module User s Manual SMACK I Specification According to the need of products research and producing at present we developed the fingerprint Safe Lock module which is based on the ARM7 platform Chapter 1 Technical specification Item Content Note ARM7 Core Samsung CPU S3C44B0X 66MHz Match speed lt lsecond FRR lt 0 01 FAR 0 0001 capacity of fingerprints 50 Include manager Working voltage DC 5V Work
10. having enrolled the manger s fingerprints When there are some enrolled manager s fingerprints and enroll the user s fingerprint it can t be performed until manager identify successfully First press the start button and then press enroll button Then red and green LED flicker at the same time this time manager puts his finger on the sensor If the manager identifies successfully buzzer will emit the sound of short whistles and then green LED flickers user can go into the enroll fingerprints process If manager s fingerprints were not successfully identified buzzer will emit one long sound whistling and then red and green LED flicker at the same time Please identify manager s fingerprints again at this time It can be enrolled more than one fingerprint continually when one user is enrolled successfully green LED will flicker and the user can keep on enrolling the next user 23 Fingerprint Safe Lock Module User s Manual SMACK When there are some enrolled manager s fingerprints and enroll the user s fingerprint operation flow as follows Press Enroll button Red and green LED flicker at the same time Repress finger Press manager s finger Failed Red LED is on and buzzer emits a long whistling It means that failed Buzzer emits long sound whistling 3 times and green LED flickers It is enable to enroll continuously Enroll again Press user s f
11. ing current lt 250mA Standby current lt 40uA Electrostatic Discharge ESD gt 15000V Power supply 1 5V AA x 4 Life length of Battery gt 2000 operations Alarm voltage 5 2 O IV electrical Start up voltage 5 6V Start up current gt 300mA Sensor Optical sensor Sensor Resolution 403dpi Image grasping area 18mm W x 16mm H Fingerprint Safe Lock Module Users Manual SMACK Working Environment 0 C 60 C Working Environment Humidity 20 80 Dimensions 57mm W x 77mm L Chapter 2 Functions d e Smack Bio S50 module Having two levels of authority of three managers and users Having function of one finger two fingers identification User can enroll delete a fingerprint and delete all users fingerprints But in case of enrollment and deletion it requires that a manager verify After successful identification it can drive the motor or electro magnetism lock detect the executant s machine s operation situation through sensor signal inspection and control it It can turn off the power supply by itself After the successful fingerprint identification driving the motor it opens a safe and module comes into standby mode When the safe s state is standby state if press the switch and then the module controls the motor to run and make the safe close Fingerprint Safe Lock Module User s Manual SMACK module comes into standby mode Customers can change the working m
12. ingerprint 1st time Press user s fingerprint 2nd time Press user s fingerprint 3rd time Buzzer emits long sound whistling 3 times and green Failed LED flickers It is enable to enroll again Buzzer emits short sound whistling 3 times and green LED flickers Continue It is enable to enroll continuously 24 Fingerprint Safe Lock Module User s Manual SMACK 3 Delete fingerprints Manager s fingerprints and user s fingerprints can be deleted respectively 1 Deleting user s fingerprints Press Start button and then press delete button At this time red and green LEDs flicker at a time and manager identifies his identity by pressing his finger first time If the manager identifies successfully buzzer will emit sound of short whistling 3 times and deleting user s fingerprints are successful After red and green LED flicker Safe goes over the process for deleting manager s fingerprints If manager identify failed red LED will flicker once at the same time buzzer emit long sound whistling once Then red and green LED flicker at a time which indicates that it needs to identify the manager s fingerprint again 2 Deleting manager s fingerprints After perform the above the user s fingerprints deleting red and green LED flicker at a time which indicates that it needs to identify the manager s fingerprint again And then manager put the finger on the sensor if you do not want to delete
13. manager s fingerprints you can skip this step and if manager s identification is successful all manager s fingerprints data will be deleted After identify was successful buzzer emits long sound whistling 3 times it 25 Fingerprint Safe Lock Module User s Manual SMACK means that it is deleting now and then emits short sound 3 times again When indicator LEDs are off manager s fingerprints are deleted successfully If the identification is failed the red LED will flicker one time and emits long sound whistling once Then red and green LED flicker it means that manager should identify again When finished above operation all fingerprints data of safe box will be deleted completely 26 Fingerprint Safe Lock Module User s Manual SMACK Deleting fingerprints data operation flow as follows Press Start button Press Delete button Red and green LED flicker Manager press his finger on the sensor Failed Success Buzzer emits short sound whistling 3 times and then emits long sound whistling 3 times which indicates that users fingerprints were deleted Then red and green LED flicker which indicates that it is enable to delete managers fingerprints Are you sure No ln cu un Yes Press a manager s fingerprint again Identification failed Identification success Buzzer emits long sound whistling 3 times and then emits short sound whistling 3 times agai
14. n LED flickers and buzzer emits a sound of short whistling At last press the same finger again After three times for pressing the finger if buzzer emits sound of three short whistling then it means that the enrollment is successful Green LED flickers continually after successful enrollment the user can enroll the next finger continually If enrollment fails the buzzer will emit the sound of three long whistling and green LED flickers At this time the user can enroll another fingerprint according to the above mentioned the step If the fingerprint repeated then buzzer will emit the sound of one long whistling red LED is off for one second and then green LED flickers At this time the user should change another finger to enroll When the user presses his finger don t move the finger and try to put your finger on the sensor flatwise As the enrolled fingerprints concern the convenience and security of using thereafter it is must to enroll seriously Fingerprint Safe Lock Module User s Manual SMACK Fingerprints enrollment operation flow Press Start button Press Enroll button Failed Buzzer emits the long sound of whistle 3 times Input again when enrollment fails Success Buzzer emits the short sound of whistle 3 times when enrollment is successful Green LED flickers It means that it is possible to enroll continually Continue Fingerprint Safe Lock Module User s Manual SMAC
15. n which indicates that all fingerprints including managers were deleted 27 Red LED flickers once and buzzer emits long sound whistling once which indicates the identification fails Then Red and green LED flicker at a time which indicates that try again End deleting Red LED flickers once and buzzer emits long sound whistling once which indicates that manager s identification fails Then Red and green LED flicker at a time which indicates that try again Fingerprint Safe Lock Module User s Manual SMACK 4 Initialization Press the Start button and then press the initialization button Buzzer emits long sound whistling 3 times it is initializing now and emits short sound whistling 3 times continuously then initialization will be completed and all the fingerprints data are deleted Please do not use this function recommend you to conceal installing the initialization button 28 Fingerprint Safe Lock Module User s Manual SMAPM IV Appendix 1 Connectors of the safe module and Signals Dip switch Optical sensor CONS RS 232 1234 eS CON7 Inside svitch CONS Outside switch w CON3 Door state CON6 Power 23 2 54 GND GND Regist Delete DeleteAll 3 3V LED Green LED Red CON4 Motor Driver X RS232 communication function is offered on the customers request CON6 Power Input DC Input 2PIN 2 54 interval Pinl GND Earthing
16. nd of short whistling after user hears the sound press the finger again After three times for pressing the finger if buzzer emits sound of three short whistling and then it means that enrollment is successful Green LED flickers continually after successful enrollment the user can enroll the next finger If enrollment is failed the buzzer will emit the sound of three long whistling And green LED flickers At this time the user can enroll another fingerprint 20 Fingerprint Safe Lock Module User s Manual SMACK according to the above mentioned the step If the fingerprint repeated then buzzer will emit the sound of one long whistling red LED flickers once and green LED flickers at this time you should change another finger to enroll When press your finger do not move finger try put finger on the sensor flatwise As the fingerprints enrollment concerns the convenience and security of using in future it is must to enroll seriously 21 Fingerprint Safe Lock Module User s Manual SMACK The first time to enroll fingerprints operation flow as follows Press start button Press Enroll button l Failed Input again Buzzer emits long sound of whistles three times Success Buzzer emits short sound of whistles three times Green LED flickers and user can enroll continuously Continue 22 Fingerprint Safe Lock Module User s Manual SMACK 2 Enrolling fingerprints
17. ode one or two fingerprint identification by the dip switch refer to Appendix 2 Dip switch for one and two fingerprints mode Fingerprint Safe Lock Module User s Manual SMACK II One finger Identification Chapter 3 Function buttons and Notice 1 Function buttons 1 Outside Function buttons Start button used for starting system 2 Inside function buttons Enroll button used for enrolling the users fingerprints Delete button used for deleting the enrolled users fingerprints it can t delete the manager s fingerprints Initialization button To delete all fingerprints including the managers fingerprints 2 Indicator LED and buzzer beep notice 1 Indicator LED D When it is in normal using situation When the green LED flickers it means that please press the finger When the green LED is on continually for 0 5 second it means that identification is successful When the red LED is on continually for 0 5 second it means that identification fails Fingerprint Safe Lock Module User s Manual SMACK 2 Enrolling or deleting fingerprints data When the red and green LED flicker continually at the same time it means that it can enroll or delete fingerprints data after be successful identified by manager When the red LED flickers once green LED flickers continually it means that a user can enroll or delete fingerprints data without identification of a manager 2 Buzzer noti
18. the user s fingerprint Press any user s fingerprint Identify failed Failed Buzzer emits three long sound whistles Identify success Red LED flickers once and then green LED flickers continuously Identify success Emit three short whistles Green LED is on for a long time unlocked Note Order of pressing the finger of user and manager can reverse it can identify user s fingerprints and then identify manager s fingerprints Fingerprint Safe Lock Module User s Manual SMACK 2 Enrolling fingerprints The safe box can contain 50 fingerprints it can be divided manager and user according to the order of enrollment and the first 3 fingerprints are managers others are users Manager has all authorities of the safe box such as enrolling deleting fingerprints and unlocking the safe User only has an authority of unlock 1 Enrolling first fingerprint Have not any enrolled fingerprints At first pressing the start button and green LED flickers pressing the enroll button after red LED flicker once green LED flickers continually mean that can enroll operation then user can put one finger on sensor flatwise If user wants to enroll one fingerprint user should press one finger three times according to the notice After the first time to press the finger green LED flickers and buzzer emit sound of short whistling After this user should press finger second time green LED flickers and buzzer emit sou
19. user s enrolled finger on the sensor if identify is successful buzzer emits continually sound of three short whistling and green LED is on for a long time fingerprints identification was successful and then the safe box is opened If the fingerprints identification is failed buzzer will emit the sound of three long whistling then after red LED flickers the green LED flickers at this time user can re input the finger to identify As for two fingers to unlock the safe it needs to enroll the 3 fingerprints of manager and at least one fingerprint of user It can be unlocked when both one of the manager s fingerprint and any one Fingerprint Safe Lock Module User s Manual SMACK of the user s fingerprint identification is successful 1 It can be unlocked only when both any one of the managers and users identification is successful 2 If manager identify successfully we can get the authority of the enrollment and deletion Namely two fingers mode can take effect to unlock and take no effect to others Fingerprint Safe Lock Module User s Manual SMACK In two fingers mode to unlock the safe box operation as follows Press start key Repress the finger Any one of the manger press the finger Identify failed Failed Buzzer emits three long sound whistles Red LED flickers once and then green LED Identify success P nuy su flickers continuously Identify success Emit three short whistles Repress
20. zation function must be use 1 Unlocking safe box 1 When there is no any enrolled user s fingerprint Leaving factory setting of safe box has no enrolled fingerprints data and it will be unlock by any user When only managers fingerprints are enrolled namely the first three Fingerprint Safe Lock Module User s Manual SMACK fingerprints it will be also unlock if the user press any finger This time and the operation flow as follows Press the start button and then green LED flickers it means that please press the finger User should put any his finger on the sensor it will be unlock while the green LED be off 2 Normal unlocking safe box When it has already enrolled user s fingerprints When the manager s fingerprints and user s fingerprint have already enrolled namely more than four fingerprints are enrolled opening safe box needs fingerprints identification This operation flow is follow After pressing start button green LED flickers and then put enrolled finger on the sensor If identification is successful buzzer emits sound continually of three short whistling and green LED is on for a long time fingerprint identification was successful and then the safe box is open If the fingerprints identification fails buzzer will emit the sound of three long whistling and the green LED flickers after red LED is on at this time user can re input the finger to identify 3 Controlling the executant mechanical