Home
Digital Multimeters
Contents
1. 4 444 1 68 Amprobe to ServiceFirst Item 68 ServiceFirst str SC Series Clamp Meters 00825 SC64 MTR00827 SC66 SC67 00826 5 68 MTR00860 SC 76 The SC line of current clamps is for the field service technician who wants to get the most out of the one meter he carries The SC64 is the basic clamp meter The SC66 is a manual ranger designed for HVAC R The SC76 has more ranges and functions plus a bar graph and 4000 counts The SC68 is perfect for those working with electrical power SC66 and SC67 Unique features for HVAC R Non contact Voltage Loud beeper and bright LED indicate the NCV tab is near ac voltages greater than 24 V Temperature Thermocouple plugs in directly for accurate readings even in fast changing environments Microamps For flame rectifier diode tests Capacitance For motor run and motor start capacitors And More Hi voltage indicator you can t miss both LED and beeper turn on to indicate you have touched a potentially dangerous voltage e Continuity indicated by LED and beeper e MAX hold automatically holds reading so you can look at the meter after you have disconnected Low ohms ranges for motor windings and mid range for thermistors e Amps ac resolution to 0 01 A for heat anticipator circuit 20 A range Up to 200 Aac with 0 1 V resolution 200 A range
2. 00096 80PK 1 Thermocouple adapter and bead probe 100 80 Thermocouple adapter and bead probe 07902 TL20 Industrial test lead set TOLO1801 FVF SC2 FlukeView forms software RSP PRC018 EN RSP PRC018 EN ServiceFirst Digital Multimeters Fluke 110 111 112 Digital Multimeters Compact meters for installers and contractors In the case of Fluke s new 110 111 and 112 smaller is definitely better These little meters pack more features than some twice their size e True rms ac voltage and current measurement for accurate readings on all waveforms e 6000 count display provides improved resolution e Min Max Average feature captures irregular activity e Frequency capacitance and resistance capabilities e 112 has a backlight to illuminate the screen in dark workspaces e Easy access battery door to change the battery without breaking the calibration seal e Drop protected to 1 meter e Holster with probe holders for two hand operation and probe storage e Compatible with ToolPak meter hanging kit e Compact and lightweight for use on the go e ECCAT III 600 V safety rating Function Range and resolution Best accuracy V dc 6000 mV 6 000 V 60 00 V 600 0 V 0 7 of reading Vac 6000 mV 6 000 V 60 00 V 600 0 V 1 0 of reading A models 111 and 112 only 6 000 A 10 00 A2 1 0 of reading A ac2 models 111 and 112 only 10 00 A2 1 5 of reading R
3. 750 MCM or 2 500 MCM 1 mV A 1 2 meter with shrouded banana plugs 60 Hrs 1 year CATIII 600 V Range Limitations 1 Ato 400 A dc and 1 Ato 400 A ac 1 Ato 400 A dc and 1 Ato 400 A ac 1 Ato 400 A dc and 20 A to 400 A ac 1 A to 400 A dc and 1 Ato 400 A ac 1 Ato 400 A dc and 1 Ato 400 A ac to 400 A dc and 20 A to 400 A ac 1 Ato 400 A dc and 2 5 Ato 400 A ac 1 Ato 400 A dc and 20 A to 400 A ac 1 A to 400 A dc and 30 A to 400 A ac 1 Ato 400 A ac 1 Ato 400 A dc and 5 Ato 400 A ac 1 Ato 400 A dc and 25 Ato 400 A ac 1 to 400 A dc and 5 Ato 400 A ac 1A to 400 A dc and 15 A to 400 A ac 4 A to 400 A dc No ac 4 A to 400 A dc No ac 1 Ato 400 A dc and 110 A to 400 A ac 1 Ato 400 A dc and 20 A to 400 A ac CMP00967 11010 1 1000 A 1 600 A 2 0 5 10 kHz Yes 1 18 30mm 750 MCM or 2 500 MCM 1 mV A 1 2 meter with shrouded banana plugs 60 Hrs 1 year CATIII 600 V 1 Ato 1000 A dc and to 600 A ac 1 A to 1000 A dc and 1 to 600 A ac 1 A 1000 A dc and 20 A to 600 A ac 1 Ato 1000 A dc and 1 to 600 A ac 1 Ato 1000 A dc and 1 to 600 A ac 1 Ato 1000 A dc and 20 A to 600 A ac 1 Ato 1000 A dc and 2 5 Ato 600 A ac 1 Ato 1000 A dc and 20 A to 600 A ac 1 Ato 1000 A dc and 30 A to 600 A ac 1 Ato 600 A ac 1 Ato 1000 A dc and 5 A to 600 A ac 1 Ato 1000 A dc and 25 A to 600 A ac 1 Ato 1000 A dc and 5 Ato 600 A ac 1 Ato 1000 A dc and 15 A t
4. e Vdc to 0 01 V resolution 20 V range Auto power off to extend battery life Test Lead Solutions e Probe storage in the back Just snap them in e Single test lead holder for easy and safe voltage testing Silicone test leads remain flexible in cold weather withstand caustic chemicals and work well in temperatures that will melt vinyl leads e Convenient lead storage e Wrap test leads through clamp to keep the wires out of the way You can even leave them right there when you test amps RSP PRC018 EN ServiceFirst SC Series Specifications for SC64 SC66 5 67 and SC68 Function Range Accuracy SC64 SC66 SC67 5 68 Resolution Ranging Manual Manual Manual Manual Counts 2000 2000 2000 2000 Bargraph Vac 2000m 1 2 3 1 200 1 2 3 0 1 600 290 5 1 750 290 5 1 Vdc 200m 0 5 1 0 1 2000m 0 5 1 1 20 0 5 1 0 01 200 0 5 1 0 1 600 0 5 1 1 1000 0 5 1 1 20 3 5 0 01 200 3 5 0 1 uAdc 200 1964 1 0 1 X X 200 F 1 F 0 1 1000 F 1 1 5 F 1 MFD 200 3 5 0 1 Hi V indicator gt 30 V LB LB L B S NCV gt 24 Vac L B L B L B Ohms 200 1 3 0 1 200 1 3 0 1k Hz 40k 0 1 3 1 Continuity B LB LB LB Diode Clean Power L LED 5 Shaker What s Included The padded ANC7 case is included with every SC series meter It has a zippered pocket and a belt loop
5. et 129 mamas 11 11 s s 1 212 20959 NENENEN 768 me pos esee epe pt et bj uj are RE 111 LES eres spe pee eere SCOPE METERS POWER METERS DIGITAL MULTIMETERS Compatibility Chart ac dc Current Clamp Compatibility Chart CONTACT PROBES 80BK Temperature Probe 80PK I through 80PK 9 80PJ 1 and 80PK 9 ac Current Clamp Compatibility Chart 80 5 PROBES 80PK IR MISCELLANEOUS 80AK 80T 150U 80TK 80CK M 1200 1200 801 400 801 600 110005 i2000flex 1410 11010 2 requires 80AK 1 requires 80TK RSP PRC018 EN 58 RSP PRC018 EN Cross Reference ServiceFirst ServiceFirst Item to Fluke SF ADP00977 CAS01261 CAS01262 CAS01263 CAS01265 CAS01266 CAS01267 CAS01268 CAS01270 CAS01271 CAS01272 CAS01273 CAS01281 CAS01285 CAS01286 CAS01297 CAS01309 CLP00954 CLP00955 CLP00963 CLP00964 CLP00965 CLP00966 CLP00983 CMP00952 CMP00956 CMP00966 CMP00967 CMP00968 CMP00969 CMP00974 CMP01025 FUS01546 FUS01560 FUS01570 FUS01574 FUS01578 07901 07902 07903 07904 07921 KIT08168 MFG 80AK C25 C510 C12A 5 550 10 50 100 781 789 90 800 520 125 H3 C20 AC20 AC80 AC83 AC85A AC89 AC87 AC72 801 400 1200 801 600A 11010 i200flex 1410 12005 80110005
6. 943121 803293 871173 P N 871207 892583 TL75 TL20 TL24 TPAK CO 205 FLUKE179 EDA KIT PAGE 28 54 31 55 31 55 29 55 56 55 56 55 56 55 56 55 56 55 28 55 56 55 48 48 48 48 48 48 29 49 50 31 50 50 51 50 27 50 50 50 56 56 56 56 56 49 28 49 47 20 28 31 57 43 27 ServiceFirst Item to Fluke SF KIT08169 KIT08266 LED00358 LED00359 LED00360 LED00361 LED00363 LED00364 LED00387 000389 MOD00268 MOD01261 MTR00831 MTR00832 MTR00833 MTR00834 MTR00836 00837 MTR00838 MTR00840 MTR00841 MTR00842 MTR00843 MTR00844 MTR00846 00847 MTR00848 MTR00849 MTR00850 00851 MTR00852 MTR00853 MTR00854 MTR00858 MTR00859 MTR00862 MTR00872 MTR00884 MTR00898 00905 00907 00932 00914 MFG FLUKE16 322 KIT 27 FLUKE112 322 KIT 27 TL23F 29 31 49 TL22 47 TL71 49 TL81A 49 TL21A 47 TL27 47 TL23R 49 648029 38 PV 350 57 SOTK 29 FLUKE 16 31 FLUKE 322 42 52 2 44 51 FLUKE 179 30 31 35 FLUKE 336 42 CO 220 43 FLUKE 112 36 FLUKE 189 28 35 FLUKE 50D 45 FLUKE 333 42 FLUKE 337 42 FLUKE 187 28 FLUKE 335 42 FLUKE 334 42 FLUKE 65 45 FLUKE 1520 39 FLUKE 177 30 31 FLUKE 77 111 30 54 2 44 51 FLUKE 111 29 T5 1000 38 FLUKE 7 600 29 31 73 III 30 FLUKE 110 29 FLUKE 12 31 FLUKE179 TPK 27 30 FLUKE 175 30 FLUKE 123 33 FLUKE 707 46 FLUKE 1550B 40 FLUKE 88 34 59 ServiceFirst 60
7. 964 966 965 CAS01267 CAS01270 CAS01286 CAS01263 501309 501261 501268 501262 501285 501266 501271 501272 44 44 28 28 28 29 28 29 31 21 38 37 37 51 51 30 54 53 54 50 50 50 92 52 52 52 52 53 92 53 53 53 54 29 48 49 48 48 48 48 48 56 56 55 55 55 55 55 99 DD 55 56 Fluke to ServiceFirst Item MFG C800 C90 205 210 220 FLUKE 12 FLUKE 1520 FLUKE1550B FLUKE 16 FLUKE 83 5 FLUKE 87 5 FLUKE 87 5 E FLUKE 175 FLUKE 189 FLUKE 322 FLUKE 333 FLUKE 334 FLUKE 335 FLUKE 336 FLUKE 337 FLUKE 50D FLUKE 65 FLUKE 707 FLUKE 77 111 FLUKE 88 FLUKE 110 FLUKE 111 FLUKE 112 FLUKE112 322 KIT FLUKE 123 FLUKE16 322 KIT FLUKE 177 FLUKE 179 FLUKE179 EDA KIT FLUKE 179 TPK FLUKE 187 FLUKE 189 FLUKE 7 600 FVF SC2 H3 H5 11010 1200 SF CAS01281 CAS01273 07921 101692 MTR00837 MTR00872 MTR00849 MTR00932 MTR00831 MTR00942 MTR00940 MTR00941 00898 009 19 MTR00832 00842 00847 MTR00846 MTR00836 MTR00843 MTR00841 MTR00848 MTR00907 MTR00851 MTR00914 MTR00862 MTR00853 MTR00838 KIT08266 MTR00905 KIT08169 MTR00850 MTR00834 KIT08169 00884 MTR00844 MTR00840 MTR00858 101801 CAS01297 CAS01265 CMP00967 CMP00956 PAGE 56 55 43 43 43 31 39 40 31 32 32 32 30 27 4
8. ServiceFirst Electrical Test Tools Fieldpiece FLUKE o TI August 2004 RSP PRCO018 EN Table of Contents 4 SC SS sk a 4 lampann 4 Data logger and Electronic Handle 7 Heavy Duty for Field Service 8 Digital ATA gg RN SEIN AR 8 Stick Style Multimeters 10 Accessories for Field Service 13 Accessory Heads sp i 13 Test 17 High Current and High Voltage 19 181518 9 20 Fieldpack Selection 21 Fieldpacks and Soft sided Cases 22 Thermometer RPM and Megohm Meter 23 BSE 24 Cross Reference 25 ServiceFirst Item to Fieldpiece 2b Fieldpiece to ServiceFirst ltem 26 isss 21 What s New from Fluke 27 Digital Multimeters 28 Multimeter Transition Guide 35 FlukeView Forms Software 37 Fluke T Series Electrical Testers 38 Fluke 1520 MegOhmWMle
9. 24 24 24 24 RSP PRC018 EN Kit content may vary by country RSP PRC018 EN ServiceFirst What s New From Fluke 08266 Fluke 112 322 KIT Electrician s Multimeter and Clamp Meter Combo Kit e 112 tru rms digital multimeter e Fluke 322 clamp meter e TL75 hard point test lead set e 800 durable carrying case 08168 Fluke179 EDA KIT Electronics Multimeter and Deluxe Accessory Kit e 179 true rms digital multimeter e 11224 SureGrip silicone test leads e L910 electronic test probes e AC280 SureGrip heavy duty hooks clips integrated temperature probe e 800 durable carrying case 08169 Fluke 16 322 KIT HVAC Multimeter and Clamp Meter Combo Kit e 16 multimeter with temperature e Fluke 322 clamp meter e L75 hard point test lead set integrated temperature probe e 800 durable carrying case KITO9555 87 Retrofit Kit for 83 85 87 3 787 meters _ C8OY replacement holster e DR80 LCD display upgrade kit e _ TL71 premium DMM test leads e 72 slide on style alligator clips e F1andF2 replacement fuses e MeterCleaner Wipes MTROO919 Fluke 189 Logging Digital Multimeter and FlukeView Forms Combo Pack e 189 logging digital multimeter plus FlukeView FVF SC2 Forms Documentation and Analysis Software e Create custom forms or reports to record test procedures and results e Documentation can est
10. 32 F to 64 F 82 F to 122 F Power Single standard 9 volt battery NEDA 1604 JIS 006P IEC 6F22 Battery life 300 hours typical with alkaline Accessories One pair test leads one pair alligator clips k type thermocouple 9V battery installed and operating instruc tions Safety UL CE Cat lll 600 UL 3111 1010 1 RSP PRC018 EN Heavy Duty for Field Service Temperature e Range 30 F 1000 F e Resolution 0 1 F e Accuracy 1 F 32 F 120 F 1 1 5 F 4 F 750 F 2 4 F 30 F 4 F 2 4 F 750 F 1000 F e Sensor type k type thermocouple e Overload protection 60 VDC or 30 rms Continuity e Audible indication Less than 400 e Response time 500ms Green LED will be on continuously e Overload protection 500VDC or rms DC volts e Ranges 400mV 4000mV 40V 400 600V e Resolution 0 1mV e Accuracy 0 596 rdg 2 dgt e impedance 560 on V inputs 10MQon mV input e Overload protection 600VDC AC rms e Transient protection 6kV for 10 sec AC volts 50Hz 500Hz e Ranges 400mV 4000mV 40V 400 600V Conversion True RMS HS36 average HS35 e Crest factor Less than or equal to HS36 Resolution 0 1mV e Accuracy 1 2 rdg 5 dgts 50Hz 60Hz 400mV range 1 5 rdg 5 dgts 2 rdg 5 dgts on 600V range e Input impedance 560k e Overload protectio
11. 40 to 500 F TOLO1691 80PK 7 Industrial Surface Probe For flat or slightly curved surfaces e Exposed junction allows direct contact with the surface being measured e Robust design for extended service life e Measurement range 127 to 600 C 196 1 112 F RSP PRC018 EN ServiceFirst Temperature Accessories Temperature Probe 11 80PK 6A Exposed Probe Use both as a surface probe and for insertion into air and non corrosive gases e Probe constructed of 304 stainless steel e Measurement range 40 C to 816 C 40 F to 500 F TCP00097 80 8 Pipe Clamp Designed for pipe surfaces from 6 4 mm 1 4 diameter to 34 9 mm 1 3 8 diameter Spring action jaw will not loosen over time ensuring repeatable measurements e Robust design for extended service life e Measurement range 29 C to 149 C 20 F to 300 F e Repeatability 0 56 C 1 F c TOLO1694 80PK 9 General Purpose Probes Use as surface probe and for insertion into air and non caustic gases e Probe constructed of 304 stainless steel 80 9 is compatible with K type thermometers e Measurement range 40 to 260 C 40 to 500 F TOLO1695 80T 150U Universal Temperature Probe For highly accurate measurement of air Surface and noncorrosive materials e Measurement range 50 C to 150 C 58 F to 302 F e Output 1 mV C or 1 mV F switch selectable TCPOO100 80BK Integra
12. ADA2 ADBF2 ADK7 ADLS2 AEK11 AHDL1 AHV28 AMD1 AMN2 AMR1 ANC1 ANC3 ANC5 ANC7 ARH4 ASH2 ASLS2 1 1 1 ATC1 ATC3 ATEXT10 ATF1 ATH4 ATIR3 ATRMS3 ATWB1 AUA2 AVG2 AVH1 DL2 DL2K13 SF 00696 CMP00876 CMP00820 CMP00821 HED00650 06114 ADP00826 06115 WIR03694 06117 ADP00868 SEN00853 HED00489 HED00648 HED00529 CAS00809 CAS00810 CAS00812 CAS01301 CAS01302 08153 HED00676 00661 00695 WIR03224 TCP00106 00107 SEN00854 FUS01536 SEN01117 SEN00858 5 00859 HED00689 HED00681 HED00495 CAS00814 HED00682 HED00780 00678 TOLO1765 TOL01919 PAGE Fieldpiece to ServiceFirst Item MFG DL2K13G EHDL1 HB74 HB74K13 HB74K27 HB74K27G HS32 HS33 HS33K14 HS33K14G HS35 HS35K19G HS35K31 HS35K31G LT16B LT17B LT17 LT83 RF16 4 RFL701 1 RFL83 4 RFM66 4 RFM70 4 RFM74 4 RFS74 4 5 64 5 66 SC67 5 68 5 76 SMG5 SIR2 SPK1 SRPM1 ols SF TOLO1920 HLD00886 TOL00305 TOL00307 TOLO1921 TOL01922 TOLO1910 MTR00881 TOL01913 TOLO1914 TOLO1912 TOL01916 TOLO1917 TOL01918 MTR00855 MTR00856 10100913 100319 06119 501137 06120 FUS01514 KIT06121 06118 06122 MTR00825 MTR00827 MTR00830 MTRO00826 MTR00860 00819 THR00058 THR00059 MTR00894 TOLO1120 PAGE 20 7 22 20 20 10 10 20 20 10 20 20 20 22 24 24 24
13. ac and dBm dBv e Internal memory for up to three days of stand alone logging of measurement changes and manually storing of up to 100 different measurements 189 only e Max to record and timestamp values in elapsed time Fast MIN MAX captures peaks to 250 us e Temperature readings in C or F using optional K type thermocouple e Enhanced ranges such as dc voltage measurements down to 10 uV ohms up to 500 MW and capacitance up to 50 000 pF e Multiple reading display with bargraph and two level backlight Safety conformance All inputs are protected to IEC 1010 1 category lll 1000 V rating and category IV 600 V rating All meters have been independently tested and approved for UL3111 CSA C22 2 No 1010 and TuV to EN61010 listing Accessories and Ordering Information Included accessories Every 180 Series comes packaged with TL71 Silicone test leads probe holder two AC72A alligator clips four AA batteries installed CD ROM user s manual and technical notes and operator s guide Ordering information ServiceFirst Item Mfg Description MTR00844 Fluke 187 Digital multimeter MTR00840 Fluke 189 Logging multimeter Recommended Accessories 180 Series DMMs ServiceFirst Item Description KIT07904 TPAK Meter hanging kit with magnet CAS01286 C125 Soft carrying case with removable outside pocket 0969 1410 ac dc current clamp ADP00977 80AK Thermocouple adapter and bead probe
14. 2 Ato 2000 500 A to 600 A 74X Series Process Meters 1 1A to 200A 1 1 A to 1000 A 11Ato 2000A 787 Process Meter 50 Ato 200A 1 200 50 to 440A 50 440A 0 2 Ato 1000 A 2 Ato 2000 A Requires PM9081 001 Adapter 50 RSP PRC018 EN RSP PRC018 EN ServiceFirst Current Clamps Included accessories The Fluke 50 Series thermometers come with 80PK 1 bead thermocouple s batteries overview manual and instructional guide on CD ROM Ordering information ServiceFirst Item Mfg Description MTR00833 52 2 Digital thermometer dual input MTR00852 54 2 Datalogging thermometer dual input Current Clamps Specifications ServiceFirst Item Mfg dc Range ac Range Accuracy Frequency Response 3dB Zero Error Adjustment Maximum Conductor Diameter Maximum Conductor Size Output Levels Output Cable Battery Life Warranty Safety Meter Compatibility 10 11 12 12B 16 18 21 23 70 73 75 77 Series Ill 26 79 Series lll 27 83 Series Ill 85 87 Series Ill 87 89 Series IV 187 189 8060A 8062A DMMs 860 Series Graphical Multimeter 39 41B Power Meter 9X Series B ScopeMeter 123 ScopeMeter 190 Series ScopeMeter Test Tools 45 DMM 705 707 Process Calibrators 715 724 725 Process Calibrators 74X Series Process Meters 787 Process Meter Requires PM9081 001 Adapter Requires PM9082 001 Adapter CMP00969 1410 1 400 A 1 400 A 3 5 0 5 3 kHz Yes 1 18 30mm
15. 200 microns of mercury e Resolution 1 micron of mercury e Accuracy 10 0 to 1000 microns 9 73 F 9 F lt 90 RH e Operating Environment 32 F to 122 F lt 75 RH e Battery 9V 00682 AUA2 Milliamp and Microamp Head Measures milliamps and microamps for flame diode test Measures 4 to 20 mA control circuits e Includes flame diode adapter kit AOK3 e Resolution 0 1 for meters with 0 1 mVdc e Accuracy dc 1 0 reading 1 digit ac 1 5 2 digits Max current 200 mA ac or dc 14 RSP PRCO18 EN RSP PRC018 EN ServiceFirsr Accessories for Field Service 00821 ACH Current Clamp Head Measures to 300 Aac e Current range 1 A to 300 A rms e Accuracy 1 5 reading 1 digit Maximum conductor size 0 91 inches 23 mm 00495 ATRIVIS3 True RMS Head e Converts digital meter to true RMS meter e Cost effective way to measure RMS e Works with current clamps 00678 AVH1 Voltage Head Records voltage using DL2 data logger or EHDL1 handle e Accuracy dc 0 5 reading 1 digit 1 0 reading 4 digits e voltage 600 V or dc e Input impedance 1 MOhm e Standard test leads plug in top 00650 Carbon Monoxide Head Measures CO in air and finds CO sources e Fast enough to locate CO source in walk around test e Three pin sensor for better performance e battery life e
16. 63 TIF ZX 2 SEN01164 63 TIF ZX 8 ELM03209 63 RSP PRC018 EN A AMPROBE RSP PRC018 EN ServiceFirst Amprobe TOLO1948 TMULD 300 Ultrasonic Leak Detector Features Detects any pressurized gas leak due to a non gas specific design Ultrasonic sensor is unaffected by contaminant for reliable testing Windy rooftop conditions do not affect sensor s ability to detect leak The PB 1 Parabola improves directionality and sensitivity for longer range testing High sensitivity allows detection of arcing electrical switchgear from a safe distance Specifications Weight 5 6 oz 160 grams with battery Height 272 Length 74 Frequency response 35 KHz to 45 KHz 6dB Power consumption 22 mA at 9 volts dc Battery life 9 volt alkaline batteries 33 hours Performance Meets the A S T M standard Battery test LED color green indicating good red indicating replace LED High intensity for outdoor visibility Case High impact ABS ServiceFirst Item Mfg Description 10101948 TMULD 300 Tool amprobe tmuld 300 ultrasonic leak detector kit NTROOSS6 AM 33 Intelligent Digital Multimeter Auto selection of voltage or resistance prevents meter s misuse Autoranging Audible continuity check Auto power off e Data hold e Diode check e Safety CAT Ill 600 V Features Range and Resolution dc Volts 4 000 V 40 00 V 400 0 V 600 V ac Volts 4 000 V 40 00 V 400 0 V 600 V Resistance 400 0 Q We use a special notati
17. Current inputs Best basic accuracy Maximum Ohms Capacitance Frequency measurement Holster Probe holder Battery door Optional ToolPak magnetic hanging strap Old Fluke 10 11 12B No 4 000 No No 1 5 0 9 40 Megohms 11 12B only None 10 11 optional No No No NEW Fluke 112 00838 Yes 6 000 Yes Yes 0 70 50 Megohms Yes Yes to 50 kHz Included Yes Yes Yes Benefits More accurate ac measurement Greater resolution Usable in dark workspaces Measures current to 10 More accurate Extended range More functionality More functionality Better protection Easy lead storage Change battery without breaking calibration seal Hang meter for hands free usage more informaion on safety ratings please see application note ABCs of Multimeter Safety available for viewing or download from www fluke com RSP PRC018 EN ServiceFirst FlukeView Forms Software Fast and easy documentation and analysis Maximize the power of your Fluke digital multimeter with FlukeView Forms Documenting Software Now you can get the professional looking documents you need and data analysis that is much more in depth than from a meter alone FlukeView Forms records charts and graphs data to help you perform in depth analysis nev And it is so easy to use FlukeView Forms comes with both standard and customizable forms You can use them immediately or customize the
18. Fluke s world class product line The 175 177 and 179 are designed tough to withstand the harshest work environments and are accurate enough to rival most bench meters 170 Series Features include e 6000 count display provides better resolution rue RMS ac voltage and current measurement for accurate readings on all waveforms e backlight to illuminate the screen in dark workspaces 177 and179 e Easy access battery door to change the battery without breaking the calibration seal e Drop protected to 1 meter e Overmolded case features integrated probe holders e Min max records irregular activity e Auto and manual hold e Compatible with ToolPak meter hanging kit Features ServiceFirst 00859 MTR00851 MTR00898 MTR00850 00834 00884 Mfg 73 111 77 111 175 177 179 179 TPK Max voltage 600 1000 1000 1000 1000 1000 True rms e Temperature Basic dc accuracy 0 396 0 396 0 1596 0 0996 0 0996 0 0696 Backlight e Min max avg e e Toolpak meter hanging kit with magnet Opt Opt Opt Included Function Range and resolution Best accuracy V dc 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V 0 9 models 177 and 179 0 15 model 175 Vac 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V 1 0 of reading Adc 60 00 mA 400 0 mA 6 000 A 10 00 A2 1 0 of reading A 60 00 mA 400 0 mA 6 000 A 10 00 A2 1 5 of reading Resistance 600 0 6 000 60 00 600
19. come with meter except the carrying case 3 ADLS2 test leads ASA2 alligators included with meter 4 ADLS2 test leads ASA2 alligators ATB1 thermocouple velcro strip ACH included with meter 5 Leads probe tips alligator case included with meter 6 Two ATB1s velcro strips included with meter 7 Included with AUA2 head 5 018 21 ServiceFirsr Accessories for ghee Fi el dpiece Field Service TOL00307 HB74K13 Includes the HB74 meter with rubber holster the ACH 300AAC accessory clamp ADLS2 silicone leads ASA2 alligator clips AHDL1 adapter handle and four pocket carrying case TOLOO913 LT17 Includes the LT17B meter the ACH 300AAC accessory clamp ATB1 thermocouple ADLS2 silicone leads and mailpouch carrying case 5 Soft Sided Cases CASO1302 8 500809 ANC CAS00812 ANC5 4 pockets 2 meters 4 heads 4 pockets 1 meter 2 heads Flat pouch 1 meter 1 head CAS00810 ANC3 CAS01301 ANC7 Briefcase 3 meters 10 heads Single pocket case for clamp meter 22 RSP PRC018 EN RSP PRC018 EN ServiceFirst Accessories for Field Service THR00059 SPK1 Pocketknife Style Thermometer e Battery LR44 included e Range 58 F to 392 F e Accuracy 3 6 F 58 F to 4 F 1 8 F 4 F to 302 F 5 4 F 302 F to 392 F e Resolution 0 1 F e Operating Environment 32 F to 122 F THR00058 SIR2 Infrared Poc
20. in the ohms mode Accessories and Ordering Information Included accessories Each model includes TL75 test leads 9 V battery installed and operator s manual In addition the Fluke 16 includes the 80BK temperature accessory and C10 holster 31 ServiceFirst FLUKE o Fluke 87V Digital Multimeter The new Fluke 87V has improved measurement functions troubleshooting features resolution and accuracy to solve more problems on motor drives in plant automation power distribution and electro mechanical equipment Accessories Fluke 87V E Industrial Electrician Combo Kit Includes special accessories to make industrial troubleshooting even more productive Save more than 50 compared with the individual purchase price 1 5 heat resistant silicone test leads B Removable test probes with 4 mm of exposed metal for use on industrial circuits C Retractable long reach alligator clips D Magnetic hanger to position and hold meter to steel surfaces E Temperature probe Included Accessories Every Fluke 80 Series V meter comes packaged with TL75 Test Leads AC72 Alligator Clips holster 9 V battery installed temperature probe 87V only CD ROM user s manual and technical notes and operator s guide 32 Digital Multimeters New Features for Maximum Productivity e Unique function for accurate voltage ServiceFirst Item and frequency measurements on MTR00942 adjustable speed motor
21. on the back Also included are silicone test leads alligator clips SC76 only battery installed manual and installed fuse SC66 SC67 and SC76 only SC67 only SC66 5 67 SC67 only and SC76 only RSP PRC018 EN 5 ServiceFirst SC Series MTR00860 SC76 Auto Ranging Clamp Meter The SC76 is your choice if you want the ability to extend the basic capabilities of the clamp meter Fieldpiece accessory heads attach to the SC76 clamp meter giving you a pool of choices when it comes to customizing your Fieldpiece toolkit Specifications for SC76 Clamp Meter Function Vac Auto Auto mVdc Aac Auto uAdc Auto MFD Ohms Auto F Hi V NCV Continuity Range 3 4 600 0 34 600 340 3400 34 300 340 3400 340 340 340k 3 4M 34M 32 120 4 750 30 4 750 1000 LED amp LED amp Beep LED amp Beep Accuracy Resolution 2 0 4 0 001 0 5 1 0 0001 0 5 1 0 1 3 0 5 0 01 5 0 5 0 1 1 0 1 0 1 3 0 5 0 1 1 2 4 0 1 1 5 4 0 001 3 0 5 0 01 1 F 0 1 1 1 5 F 0 1 2 4 F 0 1 2 5 F 1 RSP PRC018 EN ServiceFirst Data Logger and Electronic Handle TOLO1765 DL2 Data Logger Measures and records data from Fieldpiece accessory heads e 20 000 data points e _ Real time clock e Span programmable from 1 second to 999 days e Period programmable from 1 second to 999 hours e 0 01 resolutio
22. opens shorts and correct voltage drop 16 RSP PRC018 EN RSP PRC018 EN ServiceFirsr Accessories for Field Service WIRO3224 ASLS2 Silicone Test High copper stranding silicone insulated test leads Basket style strain relief Fit in test lead holders on back of SC series clamp meters and HS30 series stick meters WIR03694 ADLS2 Deluxe Silicone Test Leads Exactly like the ASLS2 with the addition of removable probe tips 06115 ADK7 Deluxe Test Lead Kit Silicone test leads removable probe tips and alligator clips for grounding KITO6114 ADA2 Dual Alligator Clips Three feet of red and black vinyl insulated cable with small alligator clips on the end KITO6117 AEK11 Silicone Test Lead Kit These test leads are unmatched in ruggedness and flexibility KITO8153 AQK3 Flame Diode Test Adapter Kit DMM jack to quick connect for flame diode Quick connect to miniplug adapter ADPOOS26 ADBF2 Flame Diode Test Adapter Kit F to F banana adapter ServiceFirsr Accessories for Ber a Field Service K type Thermocouples Use Fieldpiece K type thermocouples with any meter using the K type design The new line of thermocouples ATA1 ATAF1 ATWB1 includes alligator clips so that you can just clip to the spot you are testing You no longer need three hands to do your job All three pipe clamps are redesigned to provide faster and more accurate pipe t
23. 0 6 000 MQ 50 00 MQ 0 9 of reading Capacitance 1000 nF 10 00 uF 100 0 uF 9999 uF 1 2 of reading Frequency 99 99 Hz 999 9 Hz 9 999 Hz 99 99 kHz 0 1 of reading Temperature model 179 40 C to 400 C 40 F to 752 F 1 0 of reading 1 All ac voltage and ac current ranges are specified from 5 of range to 100 of range 2 10 A continuous 20 A for up to 30 seconds 3 Voltage frequency is specified from 2 Hz to 100 kHz Current frequecy is specified from 2 Hz to 30 kHz 00859 Fluke 73 Series Multimeter The Fluke 73 Ill is a basic autoranging multimeter with TouchHold to freeze the measurement display Includes holster and test leads 30 RSP PRC018 EN RSP PRC018 EN ServiceFirst Digital Multimeters For Combo kits see page 24 e Electricians 179 multimeter and voltage tester combo kit e Electronics 179 multimeter and delulxe accessory combo kit ToolPak The meter hanging solution e Kit includes universal hanger clips 2 hook and loop straps 2 lengths adapter and strong magnet e Combine components to meet most hanging needs Accessories and Ordering Information Included accessories Every Fluke 170 Series meter comes packaged with TL75 test leads 9 V battery installed and manual The Fluke 179 comes with an 80BK temperature probe Ordering information ServiceFirst Item Mfg Description MTR00850 Fluke 177 Digital Mu
24. 0m 2000m 20 200 600 Vdc 200m 2000m 20 200 600 AAC 2001 20m 200m 2 10 ADC 201 200 20 200 2 10 MFD 20 200 2k 20k Ohms 200 2k 20k 200k 2M 20M 200M F 200 1000 Hi V Phase Rotation Frequency Accuracy Resolution 1 5 4 0 1 1 2 4 0 01 2 4 0 1 1 1 0 1 1 1 0 01 1 1 0 1 1 1 1 1 5 3 0 1 1 5 3 0 01 1 5 3 0 1 3 4 0 001 3 5 3 01 1 1 0 01 1 1 0 1 1 1 0 01 1 1 0 1 2 5 1 0 001 2 3 0 01 490 10 0 01 4 10 0 1 4 10 0 001 1 4 0 1 1 4 0 001 1 4 0 1 1 4 0 001 290 4 0 01 290 4 0 1 1 F 0 1 1 1 5 F 1 LT83 HB74 lt XJ X X X X gt gt lt ServiceFirst LT16B X X X X X X lt X X X X lt gt X lt LT17B X XJ XK X X X Xx LT83 gt lt lt X ServiceFirst Heavy Duty for Field Service Fleidplgce TOLO1910 HS32 MTROOSS81 HS33 TOLO1912 HS35 Unique Features for HVAC R Just snap the head onto the meter or use deluxe silicone leads for remote connection Non contact Voltage Loud beeper and bright LED indicate the NCV tab is near ac voltages down to 24 Vac Auto ranging HS35 Automatically changes range for best resolution Temperature HS33 HS35 Thermocouple plugs in directly for accurate readings even in fast changing environments Microamps HS35 For flame rectifier di
25. 2 3A 600 V fuse For units with 10 A input using a 20 Afuse use P N 892583 15A 600 V fuse 27 CAT 5 gt 7247001 P N 943121 440 mA 1000 V fuse and P N 803293 11A1000 V fuse FUS01578 45 S N lt 7211001 P N 892583 550mA 250 V fuse and P N 892583 15A600 V fuse FUS01578 73 Iland73 lll P N 892583 15 A 600 V fuse FUS01546 863 865 867 867B P N 943121 440 mA 1000 V fuse and 11 A 1000 V fuse FUS01560 83 85 87 S N gt 65650001 P N 803293 87 89 1 187 189 83 11 85 411 87 11 87 11 23 11 77 11 26 11 79 1 175 177 179 FUS01560 111 112 P N 803293 11 A 1000 V fuse RSP PRC018 EN RSP PRC018 EN ServiceFirst Miscellaneous Accessories Pressure Vacuum and Gas IMODOO268 PV 350 Pressure Vacuum Module e Digital pressure and vacuum measurements in a single module e Measures HVAC R hydraulic and pneumatic pressures 500 psig 3447 kPa e Measures to 29 9 Hg 76 cm Hg vacuum not intended for measuring microns of vacuum e Compatible with most popular digital multimeters Hanging and Locking Kits KITO7904 ToolPak The meter hanging solution e includes universal hanger clips 2 hook and loop straps 2 lengths adapter and strong magnet e Combine components to meet most hanging needs e Attaches to back of many Fluke meters including 110 170 180 Series 80 Series IV 725 Process Calibrator 70 Series lll DMMs and 50 Series II Digital Thermomet
26. 2 42 42 42 42 42 45 45 46 30 34 29 29 29 36 27 33 27 30 31 30 31 35 27 27 30 28 28 35 31 28 37 56 56 51 31 50 61 ServiceFirst 62 FLUKE o Cross Reference Fluke to ServiceFirst Item MFG i200flex 1200 1410 P N 803293 P N 871173 P N 871207 P N 892583 P N 943121 PV 350 13 15 1000 T5 600 TL71 TL20 TL21A TL22 TL23F TL23R TL24 TL27 TL75 TL81A TP1 TP2 TP20 TPAK SF CMP00968 CMP00974 CMP00969 FUS01560 FUS01570 FUS01574 FUS01578 FUS01546 MOD00268 TOLO1689 00854 TOL01669 LED00360 KIT07902 LED00363 LED00359 LED00358 LED00387 KIT07903 LED00364 KIT07901 LED00361 TOL01685 101743 101670 07904 50 50 28 51 56 56 56 56 56 57 38 38 38 49 28 49 47 47 29 31 49 49 47 47 49 49 47 47 47 28 29 31 57 RSP PRC018 EN ServiceFirst TIF Instruments Inc Refrigerant Leak Detectors ServiceFirst Item Mfg SEN01162 SEN01163 KIT08170 5 01164 ELM03209 TOLO1960 TOLO1957 KIT08224 TOLO1961 TOLO1956 10102144 1 TIF ZX 1 TIF XP 2 TIF ZX 2 TIF ZX 8 TIF 4000A TIF 5201 TIF 555 TIF 5750A TIF H10A TIF RX 1A Description Sensor TIF XP 1 refrigerant leak detector detects all halogenated refrigerants Sensor TIF ZX 1 heated pentode refrigerant leak detector detects all halogenated refrigerants Kit maintenance kit for TIF XL
27. 5 of reading 3 LSD 4 000 V 40 00 V 400 0 V 1 9 of reading 8 LSD dc 1 5 of reading 4 LSD ac 2 0 of reading 5 LSD 0 400 0 Q 4 000 40 00 0 6 of reading 4 LSD 400 0 kQ 0 4 000 MQ 4 000 k amp 2 40 00 400 0 2 40 00 MQ 500 0 nF 5 000 pF 50 00 uF 3 5 of reading 6 LSD 500 0 uF 3000 uF 10 Hz to 100 kHz 0 5 of reading 4 LSD with test leads 4 F to 572 F 2 0 of reading 6 F 20 C to 300 F 5 We use special notation to indicate range and resolution using a single number For example number 40 00 indicates a range of 40 and resolution 0 01 two digits after the point with the 1 as an increment unless otherwise specified For other ranges see Website at www advancedtestproducts com RSP PRC018 EN RSP PRC018 EN ServiceFirst Amprobe 909 AMB 1A Analog Megohmmeters Insulation Testers e Tests insulation of wires cable transformers and electrical motors e Battery powered e Helps cut unscheduled downtime and reduce shock hazards e Sensitive ohmmeter for checking resistance of motor windings AMB 1A and AMB 2 e in voltmeter e Battery OK test e Mirror scale e Automatic discharge of equipment capacitance for safe removal of test leads Features Insulation resistance with 250 Vdc test voltage N A Insulation resistance with 500 Vdc test voltage 0 100M Voltmeter 0 600 V ac dc Low resistance 0 100 Q No
28. 6115 06117 06118 06119 06120 06121 06122 08153 MTR00819 MTR00825 MTR00826 00827 MFG ADBF2 AHDL1 ANC1 ANC3 ANC5 ATWB1 ANC7 ACDC6 ACH ACA1000 RFL701 1 RFM66 4 ATC1 ATRMS3 AMR1 AMN2 ACM3 ARH4 ARH3 AVH1 ATIR3 AUA2 ATH4 ASH2 AAV3 AVG2 EHDL1 ADA2 ADK7 AEK11 RFM74 4 RF16 4 RFL83 4 RFM70 4 RFS74 4 AQK3 SMG5 5 64 SC68 SC66 PAGE 17 7 22 22 22 18 22 22 19 15 19 24 24 18 16 15 16 14 15 13 13 15 13 14 19 15 14 14 7 17 17 17 24 24 24 24 24 17 23 4 4 4 ServiceFirst Item to Fieldpiece SF MTR00830 MTR00855 MTR00856 MTR00860 MTR00881 MTR00894 5 00853 5 00854 5 00858 5 00859 5 01117 00106 00107 THR00058 THR00059 TOL00305 10100307 100319 10100913 1001120 TOL01765 0101910 TOLO1912 TOL01913 TOLO1914 TOLO1915 TOL01916 TOLO1917 TOL01918 TOL01919 0101920 0101921 0101922 WIR03224 WIR03694 MFG 5 67 LT16B LT17B 5 76 533 SRPM1 AHV28 ATB1 ATEXT10 ATF1 ATC3 1 1 SIR2 SPK1 HB74 HB74K13 LT83 LT17 ST3 DL2 HS32 HS35 HS33K14 HS33K14G HS35K19 HS35K19G HS35K31 HS35K31G DL2K13 DL2K13G 74 27 HB74K27G ASLS2 ADLS2 PAGE 25 8 ServiceFirst 26 Cross Reference Fieldpiece to ServiceFirst Item MFG AAV3 ACA1000 ACDC6 ACH ACM3
29. 86 MTRO00909 MTR00915 MTR00918 MTR00925 MTR00933 MTR00934 MTR00935 TOLO1948 TOL01953 Amprobe to ServiceFirst Item MFG PAGE MFG SF PAGE AM 33 65 ACD 14 MTR00915 66 AMB 1A 6 ACD 10 Pro MTR00918 66 ACD 14 66 ACD 10 TRMS MTR00925 66 ACD 10 Pro 66 AM 33 00886 65 ACD 10TRMS 66 AMB 1A MTRO00909 67 VP 600 67 PRM 1 101953 67 VP 600B 67 TMULD 300 TOL01948 65 VP 600SB 67 VP 600 MTRO00933 TMULD 300 65 600 00934 1 67 VP 600SB MTR00935 Literature Order Number RSP PRC018 EN Filing Hierarchy Service Products Tools and Test Equipment Test Instruments Date Month and Year August 2004 Supersedes RSP PRC018 EN 0203 Stocking Location Inland Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice Only qualified technicians should perform the installation and servicing of equipment referred in this publication
30. FLUKE o Cross Reference ServiceFirst Item to Fluke SF 00919 00940 00941 MTR00942 096 00097 00099 00100 101 111 TOLO1669 TOL01670 TOLO1671 TOLO1685 TOL01686 TOL01687 TOL01688 101689 101690 101691 101692 101693 TOLO1694 101695 101801 FLUKE 189 FLUKE 87 5 FLUKE 87 5 E FLUKE 83 5 SOPK 1 SOPK 8 SOPK 4A SOBK 80 SOPK 6A 15 600 TP20 TP1 SOPK 3A SOPK 2A 13 SOT IR SOPK 7 210 9 807 1500 FVF SC2 PAGE 27 32 22 22 29 52 53 52 28 53 54 53 38 47 37 47 52 52 52 38 54 52 43 37 53 53 28 37 RSP PRC018 EN RSP PRC018 EN Cross Reference ServiceFirst Fluke to ServiceFirst PAGE 648029 1AC 1LAC 52 2 54 2 73 80 SOBK 80 80110005 801 400 801 600 SOPK 1 SOPK 2A SOPK 3A SOPK 4A SOPK 5A SOPK 6A SOPK 7 SOPK 8 SOPK 9 80 1500 SOT IR 80 20 AC72 AC80 AC83 AC85A AC87 AC89 C10 C100 C125 C12A C20 C25 C50 C510 C520A C550 C781 C789 SF LED00389 TOL01671 TOL01693 MTR00833 MTR00852 MTR00859 ADP00977 TCP00100 TCP00101 CMP01025 CMP00952 CMP00966 TCP00096 TOL01687 TOL01686 TCP00099 TOL01688 TCP00111 TOL01691 TCP00097 TOL01694 TOL01695 TOL01690 MOD01261 CLP00954 CLP00983 CLP00955 CLP00963
31. H head micro milliamps head with AOKS flame diode kit alligator clip thermocouple wet bulb thermocouple vacuum gauge electronic handle data logger SMG5 megger air velocity head voltage head AVH1 and upgrades to ANC3 briefcase style bag TOLO1918 HS35K31G HS3K31 plus ACMS carbon monoxide and AMN2 manometer heads 20 RSP PRC018 EN ServiceFirst Accessories for Field Service Fieldpack Selection Guide Model HS33K14 HS35K19 HS35K31 HB74K27 012 13 Meter 2 Description EHDL1 Electronic handle X X X X DL2 Data logger less case X X HB74 3 Heavy duty DMM X HS33 4 Manual ranging stick 535 4 Auto ranging stick SMG5 5 Megger Leads adapters ADA2 Dual alligator clips ASA2 Small alligators pr 4 4 4 X AHDL1 Adapter handle Flame diode kit 2 7 X 7 X 7 Case ANC3 Briefcase 8 Mid sized case Thermocouples ATA1 Alligator clip X X X X ATWB1 Wet bulb X X ATC1 Small pipe clamp Premium pipe clamp Heads AAV3 Air velocity Amp clamp 4 4 4 ACM3 Carbon monoxide 1 1 1 1 1 AMN2 Manometer 1 1 1 1 1 ARH4 Temp WB X X ATH4 6 Dual temp AUA2 Micro milliamps X AVG1 Vacuum gauge X X X X AVH1 Volts 1 Add G suffix to model number to include and 2 2 Includes all accessories that normally
32. Optional pump 1609 ACMP3 e Auto off can be disabled for data logging e Select averaging or normal for smoothing or fast response to change e Range 0 to 1000 ppm 2000 ppm with 5 minute max exposure time e Initial accuracy 0 15 ppm 5 reading 1 ppm after zeroing 15 35 ppm 5 reading 2 ppm after zeroing 0 1000 ppm 5 reading 5 ppm after zeroing e Response time 70 sec to 90 of reading e Operating temperature 32 F to 105 F e Sensor type Electrochemical specific to CO e KITO7930 includes both ACM3 and PMP01609 HEDOO695 ASH2 Superheat Head Measures refrigerant pressure and temperature and calculates superheat for two refrigerants in English or metric units e Display pressure in PSI or kPa e Display temperature in F or C e Display superheat in F or C e Select R22 or R410A e Auto off can be disabled for data logging 15 ServiceFirsr Accessories for Fi dpiece Field Service HEDOO529 1 Milliohm Head Use to catch winding to winding shorts on motors and transformers e _ Range 1 milliohm to 2 ohms Resolution 1 milliohm e Accuracy 2 of reading 2 milliohms Test current 50 m Adc 00489 AMD1 Microwave Oven Diode Tester Head Tests high voltage diodes commonly found to fail in microwave ovens Diode test on DMM cannot test high voltage diodes e Contains 9 V battery to test high voltage diodes e identifies
33. RX and XP leak detectors includes 3 tips and 3 protectors Sensor replacement heated pentode sensor for TIF ZX 1 leak detector Element filter element for TIF ZX 1 leak detector 10 pack Tool TIF 4000a electronic sightglass Tool leaksource for TIF H10A leak detector Kit maintenance kit for TIF refrigerant leak detectors includes 3 tips and 3 protectors Tool TIF 5750A super scanner refrigerant leak detector includes case and spare sensing tip Tool TIF H10A pump style refrigerant leak detector works on all cfc hcfc and hfc leaks Tool TIF RX 1A leak detector includes molded carrying case Carbon Monoxide and Combustible Gas Detectors ServiceFirst Item SEN01167 SEN01169 SEN01168 SEN01165 SEN01166 00130 Mfg 8500 8501 8505 8800 8800 8801 Description Sensor TIF 8500A carbon monoxide analyzer Sensor replacement filter for TIF 8500a Sensor replacement sensor for TIF 8500a Sensor TIF 8800 combustible gas detector Sensor TIF 8800A combustible gas detector Tip sensing tip for TIF 8800 combustible gas detector Refrigerant Scales and Meters ServiceFirst Item TOL01952 TOLO1958 Micron Gauge Mfg TIF 9010A TIF 9020 ServiceFirst Item Mfg TOL01965 SEN01174 HSE01393 TIF 9450D TIF 9453 TIF 9454 Capacitor Tester ServiceFirst Item TOLO1964 Mfg TIF 660 Description Tool TIF 9010A slimline refrigerant s
34. V ac 50 60 Hz 50 VA 10 to 15 30 VA 20 C to 50 C 4 F to 122 F 20 C to 65 C 4 F to 149 F 80 at 31 C decreasing linearly to 50 at 40 C 0 to 2000 meters IP 40 EN 61010 1 CAT Ill 600 V EN61557 PARTS 1 2 600 V ac continuous Quicklink 1550 software requires a PC running Windows 95 98 Me 2000 NT4 0 Included Accessories e Test leads and 5000 V rated probes e Alligator clips e Interface adapter and cable e Quicklink 1550 PC software e Line cord e carrying case e Users manual 41 ServiceFirst FLUKE o the jobs you do e Backlight available on most models e Controls positioned for one hand operation breaker or overload unit sees it selected models e Accurate low current measurements e Auto shutoff e Display hold Fluke 320 330 Series Clamp Meters Choose from several new models to get the right combination of features and functions Fluke 320 and 330 Series Clamp Meters offer an impressive array of innovative features with current ranges up to 1000 A Choose the model that matches Small body and jaws fit perfectly in your hand and into tight places e inrush current feature measures motor starting current the way a circuit e Includes batteries test leads instruction card safety sheet and carrying case e Safety rating IEC 1010 2 031 600 V CAT Ill Specifications 23 C 5 C RH 0 909 ServiceFirst Item Mfg I
35. Vacuum and Gas 57 Hanging and Locking Kits eese 57 Accessory Compatibility Chart 58 Cross 59 ServiceFirst Item to Fluke 2 2 1 4 59 Fluke to ServiceFirst ltem 61 TIF Instruments 63 Refrigerant Leak Detectors esee 63 Carbon Monoxide and Combustible Gas Detectors 63 Refrigerant Scales and 63 Micron Gauge Mec m 63 Capacitor Tester nn 63 Recovery MAC MIN ii 63 Cross 64 ServiceFirst Item to 2 2 0 0 64 TIF to ServiceFirst Item eese 64 AIIDEFODG 65 Ultrasonic Leak Detector 2 2 2 2 1 65 Intelligent Digital Multimeter esse 65 Tech Clamp Digital Clamp on Multimeter 66 Analog Megohmmeters Insulation Testers 67 Non Contact Volt Probe berti opm eins ibi redis 67 Phase Sequence and Motor Rotation Tester 67 Cross 68 ServiceFirst Item to
36. ablish long term analyses and troubleshooting data of various processes for use in preventative maintenance schedules e Includes software infrared adapter cable and connector MTROOSS4 Fluke 179 TPAK and ToolPak Magnetic Meter Hanging Strap Combo Pack e Fluke 179 true rms digital multimeter plus TookPak Magnetic Meter Hanging Strap oolPak to hang your meter almost anywhere nail hook pipe or other object e Strong magnet will attach to an electrical panel metal doorjamb or any other ferrous type metal e Includes a universal hanger a magnet and a 17 inch 23 cm hook and loop 27 strap ServiceFirst FLUKE o FlukeView Forms documentation and analysis software Form generating software for PCs Places measured data from the Fluke 187 or 189 into professional looking documents that may be customized Allows meter and PC to communicate via infrared port FVF SC2 includes software infrared adapter cable and connector 28 Digital Multimeters Fluke 180 Series Digital Multimeter The Fluke 180 Series deliver breakthrough features and performance in an easy to use format to help you solve the toughest problems e 0 025 basic dc accuracy Duty cycle pulse width e Battery and fuse access door e 50 000 resolution with instant readings for detailed analyses e 100 kHz ac bandwidth for troubleshooting modern electronics e rue rms
37. al 1000 hour life e Battery door allows easy battery replacement without breaking the calibration seal Powerful data logging capabilities The Fluke 54 Series can log up to 500 points of data to internal memory e User adjustable recording intervals e Real time clock captures the exact time of day of events e Recall function allows logged data to be easily reviewed the meter display e For further analysis and graphing data be exported to optional FlukeView PC software using the thermometer s IR communication port Accessories and Ordering Information Included accessories The Fluke 50 Series thermometers come with 80PK 1 bead thermocouple s batteries overview manual and instructional guide on CD ROM Ordering information ServiceFirst Item Mfg Description MTR00833 52 2 Digital thermometer dual input MTR00852 54 2 Datalogging thermometer dual input FlukeView Forms for Temperature Documentation and analysis software for Fluke 53 and 54 Series Il thermometers Here s a fast and easy way to document store and analyze temperature measurements from Fluke s newest digital thermometers e Produce professional looking documents e n depth analysis with records charts and graphs e Standard and customizable forms e Export data to other measurement analysis programs Infrared interface between thermometer and PC makes data transfer fast and easy e Optional IR adapter and ca
38. ble for PCs without an IR port RSP PRC018 EN ServiceFirst Digital Thermometers 00848 Fluke 65 Infrared Thermometer Laser quick Fluke tough The Fluke 65 Infrared Thermometer is ideal for quick non contact surface temperature measurement of rotating hard to reach electrically live or dangerously hot targets Targeting objects is easy with the bright laser beam The large backlit display is easy to read even in the dark Most importantly the shock absorbing holster helps to create one of the most rugged IR thermometers in the industry Fluke 65 Infrared Thermometer Specifications Range 40 500 C 40 to 932 TISSUE Response time Less than 1 second Resolution 0 1 up to 200 1 over 200 Repeatability x1 or 196 whichever is greater Accuracy Above 0 C 32 F x 2 C 4 F Below 0 C 32 F 5 C 9 F with instrument stable at 23 C 3 C Optical resolution 8 1 distance to spot size ratio Emissivity Fixed at 0 95 Battery life Approximately 4000 measurements 2xAA NITROOS41 Fluke 50D Dual input Great for measuring input output changes and differential trends e Dual channel with differential output 11 12 e Min Max recording to capture events e Scan function continuously scans through measurement sequence T1 T2 T1 T2 Features Thermocouple types K J Number of inputs Dual Rugged design with holster Differential T1 T2 readout Specifications T
39. cale Tool Promax ADS 100 slimline refrigerant scale 200 capacity Description Tool TIF 9450D digital micron gauge reads 500 000 to 200 microns Sensor sensing probe assembly for TIF 9450D micron gauge Hose connector hose with filter for TIF 9450D micron gauge Description Tool TIF 660 capacitor tester range 1 2000 mfd 63 ServiceFirst 64 Cross Reference ServiceFirst Item to TIF SF MFG PAGE ELM03209 TIF ZX 8 63 HSE01393 TIF 9454 63 KIT08170 TIF XP 2 63 KIT08224 TIF 555 63 SEN01162 TIF XP 1 63 SEN01163 TIF ZX 1 63 SEN01164 TIF ZX 2 63 SEN01165 TIF 8800 63 SEN01166 TIF 8800A 63 SEN01167 TIF 8500A 63 SEN01168 TIF 8505 63 SEN01169 TIF 8501 63 SEN01174 TIF 9453 63 130 TIF 8801 63 TOLO1952 TIF 9010A 63 101956 TIF H10A 63 10101957 TIF 5201 63 10101958 TIF 9020 63 10101960 TIF 4000A 63 TOLO1961 TIF 5750A 63 10102144 TIF RX 1A 63 10101964 TIF 660 63 TOL01965 TIF 9450D 63 TIF to ServiceFirst Item MFG SF PAGE TIF 555 KIT08224 63 TIF 660 TOLO1964 63 TIF 4000A TOLO1960 63 TIF 5201 TOLO1957 63 TIF 5750A TOLO1961 63 TIF 8500A 5 1167 63 TIF 8501 5 1169 63 TIF 8505 SEN01168 63 TIF 8800 SEN01165 63 TIF 8800A SEN01166 63 TIF 8801 00130 63 TIF 9010A TOLO1952 63 TIF 9020 TOLO1958 63 TIF 9450D TOLO1965 63 TIF 9453 SEN01174 63 TIF 9454 HSE01393 63 TIF H10A TOLO1956 63 TIF RX 1A TOL02144 63 TIF XP 1 SEN01162 63 TIF XP 2 KIT08170 63 TIF ZX 1 SEN01163
40. case with three compartments removable handle and shoulder strap CAS01270 C100 Meter and Accessory Case e Tough polypropylene case e Holds any Fluke DMM or digital thermometer and most accessories CAS01281 C800 Meter and Accessory Case e Tough polypropylene case e Holds many of the Fluke or digital thermometers e Accessories and manual compartments e Detachable lid Holsters 501267 C10 Meter Holster e Snap on yellow holster absorbs shocks and protects meter from rough handling e ncludes built in stand and hanger loop CAS01265 H5 Electrical Tester Holster e Rugged fabric holster includes flap for lead storage and built in belt loop Fits Fluke 2 and 5 testers CAS01297 H3 Clamp Meter Holster e Rugged fabric holster includes flap for lead storage and built in belt loop o Fits Fluke T2 and T5 testers Fuse Selection Chart ServiceFirst Fluke Model Mfg Fuse Fuse Requirements Item FUS01578 21 23 75 77 1 P N 892583 630 mA 250 V in series with either 871202 3A 600 V fuse or fusible resistor R20 DO NOT SUBSTITUTE FOR R20 15A 600 V fuse Also recommended replacement for units with a fused 10 A input using a 20 A fuse FUS01560 21 11 75 11 803293 630 mA 250 and 11 1000 V fuse FUS01574 76 29 79 1 P N 871207 1A 600 V fuse and FUS01578 83 85 87 S N lt 65650001 P N 892583 15A 600 V fuse FUS01570 25 27 P N 871173 630 mA 250 V fuse in series with P N 87120
41. drives and MTR00940 other electrically noisy equipment MTR00941 e in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument e Optional magnetic hanger for easy setup and viewing while freeing your hands for other tasks e Large digit display with bright two level backlight makes the 87V signifi cantly easier to read than older models Electrical Safety All inputs are protected to Category Ill 1000 V and Category IV 600 V They can withstand impulses in excess of 8 000 V and reduce risks related to surges and spikes Features True rms ac voltage and current for accurate measurements on non linear signals Selectable filter for accurate voltage and frequency measurements on motor drives 0 0596 dc accuracy 4 1 2 digit mode for precise measurements Built in thermometer lets you carry one less tool Large display digits and 2 level bright white backlight for increased visibility 10 0001 capacitance range for components and motor caps Peak capture to record transients as fast as 250us Measure up to 1000 V ac and dc Measure up to 10 A 20 A for up to 30 seconds Auto and manual ranging for maximum flexibility Analog bargraph Resistance continuity and diode test Frequency to 200 kHz and 96 duty cycle Min Max and average recording to capture variations automatically Relative mode to remove test lead resistance from low ohms measurements Improved sleep mode for lo
42. e indicator and auto shutoff e Autodischarge of capacitive voltage charges e Heavy duty test leads alligator clips and test probes e Rugged splash proof case with impact absorbing holster Safety conformance Electrical safety Meets IEC 1010 1 and EN 61557 Protection class Pollution degree 1 Overvoltage category IEC 1010 1 CAT 600 V Environmental specifications e Operating temperature 10 C to 50 C e Storage temperature 40 C to 70 C e Humidity without condensation 75 RH 40 C Dust water resistance IP42 per IEC 529 0 Operating Altitude 2 500 meters Accessories and Ordering Information Included accessories TL27 heavy duty test leads TP74 lantern tip test probes AC86 large jaw alligator clips protective holster with hand strap carrying case with accessory storage four C cell alkaline batteries instruction manual instruction manual on CD ROM Ordering information ServiceFirst Item Mfg Description 00849 Fluke 1520 MegOhmMeter RSP PRC018 EN 39 ServiceFirst 40 FLUKE o Fluke 1550B MegOhmMeter MTROO932 Fluke 1550B Digital Insulation Testing up to 5000 V The Fluke 1550B is a digital megohmmeter capable of testing switchgear motors generators and cables at up to 5000 V dc It can be used for a wide range of tests from simple spot checks to timed tests and breakdown tests Measurement storage and PC interface
43. emperature measurement accuracy Type K 0 1 0 7 C 1 3 F For temperatures above 100 C Type J 0 1 0 8 C 1 4 F Measurement range depending on thermocouple type 200 C 328 F to 1370 C 2498 F Display resolution 0 1 C 0 2 F over full range Battery life typical 800 hours 9 V Weight 280 10 RSP PRCO18 EN 45 ServiceFirst FLUKE o 46 Loop Calibrator IVITROO907 Fluke 707 Loop Calibrator e nnovative output adjustment dial on 707 provides 1 pA and 100 pA resolution and one hand operation e Large display and simple interface for ease of use e Simultaneous mA and readout for quick easy interpretation of readings e mA accuracy of 0 015 on the Fluke 707 and 0 02 on the 705 e HART mode 707 connects 250 ohm resistor in series with 24 V loop for compatibility with HART communicators e Push button 25 steps for fast easy linearity checks Span Check for fast confirmation of zero and span e Selectable slow ramp fast ramp and step to provide smooth outputs for valve slewing and loop functional tests e 24V internal loop supply so you can power and read a transmitter at the same time without carrying a DMM e 0 20 mA or 4 20 mA default start up modes Functions Fluke 707 Voltage measurement Range 0 28 V Resolution 1 mV Accuracy 0 015 reading 2 LSD Current measurement Range 0 24 mA Resolution 0 001 mA Accuracy 0 015 reading 2 LSD Cu
44. emperatures Wrap tab plug Wrap the lead wire around the tab for convenient lead storage a ServiceFirst Mfg Description Max F 7 Item tip PT TCP00106 1 Bead type with alligator 400 107 ATAF1 Bead type with alligator high temp 900 SEN00854 ATB1 Bead type 400 FUS01536 ATC1 Pipe clamp up to 1 1 4 200 SEN01117 ATC3 Pipe clamp up to 1 3 8 300 SEN00858 ATEXT10 Thermocouple 10 extension cable 900 SEN00859 ATF1 6 stainless tip designed for fluids 1500 CAS00814 1 Wet bulb sock with alligator 150 RSP PRC018 EN RSP PRC018 EN ServiceFirsr Accessories for Field Service High Current and High Voltage Accessories 0876 1000 1000AAC Current Clamp Reads amps directly on any Fieldpiece meter so there 15 no need to mentally move decimal points e Accuracy 400 A 60 Hz 1 5 reading 2 e Accuracy gt 400 A 60 Hz 2 reading 2 e opening 2 25 2 75 x 0 70 bus bars CMPOOS20 ACDC6 and dc Current Clamp Connect to any digital multimeter with industry standard jacks to measure ac or dc current up to 600 A Reads amps directly on any Fieldpiece meter so there is no need to mentally move decimal points e accuracy 2 reading 2 e accuracy 60 Hz 400 A 2 reading 2 e accuracy 60 Hz gt 400 A 6 reading 2 SEN00853 AHV28 High Voltage Probe Connect to any digital m
45. ers 57 SERVICEFIRST _ _ Accessory Compatibility Table FLUKE o Find the Right Accessories 5931531 41 61 21 a Coo oo pte PROCESS METERS oe 531935 vs cs 531935 26 16 aos sos 53 35 06 BH 17 65 2 93 531935 081 Salas 68 B 3143 8 28 58 DIGITAL SCOPE METERS POWER METERS uitable for multiple meters accessories and other tools ee 0c IIl 531995 6 6 31935 54 04 DIGITAL MULTIMETERS QZL ZL LL OL EBEN 009 005 4 Compatibility Chart PREMIUM CASES C510 Case and Holster METER HANGING SOLUTIONS VINYL AND NYLON CASES ToolPak C520 C550 C12A C25 C31 C50 C90 C125 C789 HARD CASES C100 C800 HOLSTERS C10 H110 H5 LockPak ___ eee 2 5 210 pese sees 841111 I pet TTT 2 TT ee eee eee ee eee Loos PROCESS METERS E DIGITAL esses S 11411114 111111 11 asawasos cet tT prr e eee ee ine ee SED a ND ZIEL CLA AR RR ad ES 29 22 09 151711 115 1315 515151 e 281 JJ
46. esistance 600 0 Q 6 000 60 00 600 0 6 000 40 00 1 5 of reading Capacitance 1000 nF 10 00 uF 100 0 pF 9999 uF 1 9 of reading Frequency 99 99 Hz 999 9 Hz 9 999 Hz 50 00 kHz 0 1 of reading 1 Specified from 5 of range to 100 of range For Aac 5 of range is relative to 60 A 2 10 A continuous 20 A for up to 30 seconds not specified below amps 3 Voltage frequency is specified from 5 Hz to 50 kHz Current frequecy is specified from 50 Hz to 5 kHz Battery life 300 hours typical for alkaline Size with holster H x Wx L 4 6 cm x 9 6 cm x 10 0 cm Three year limited warranty Accessories and Ordering Information Included accessories Every Fluke 110 Series meter comes packaged with a H110 protective holster and TL75 test leads 9 V battery installed and manual Ordering information ServiceFirst Item Mfg MTR00862 Fluke 110 MTR00853 Fluke 111 MTRO00838 Fluke 112 Recommended Accessories 110 Series DMIVIs ServiceFirst Item Mfg Description KIT07904 TPAK Meter hanging kit with magnet CAS01263 C12A Soft vinyl carrying case CLP00983 AC72 Alligator clips that push onto test lead probes LED00358 TL23F Electrical test lead set MOD01261 80 Thermocouple module converts a DMM into a thermometer 29 ServiceFirst FLLIKE Digital Multimeters Fluke 73 77 175 177 and 179 Digital Multimeters The 170 Series delivers three new feature packed to
47. format to fit your specific applications With the Fluke 189 89 Series IV and 53 54 Series ll meters you do not have to have the meter and computer running together to take your measurements These meters can measure and store hundreds of logged and saved reading measurements as stand alone units and then later download the information to FlukeView Forms when you connect to your computer pem om Operating system requirements Windows 95 or later Windows NT 4 0 or later or Windows 2000 and Windows XP Minimum recommended PC hardware Pentium class microprocessor 32 MB RAM 70 MB hard disk space 100 MB to install ServiceFirst Item Description TOLO1801 FVF SC2 FlukeView Forms 1 6 Software with cable for Fluke 180 Series TOLO1671 VoltAlert 1AC is for detecting line voltage from 90 V ac to 600 V ac Test voltage with easy to use detectors VoltAlert ac voltage testers from Fluke are easy to use just touch the tip to a control wire conductor or outlet When it glows red you know there s voltage in the line Electricians maintenance service safety personnel and homeowners can quickly test for energized circuits and defective grounds on the factory floor in the shop or at home TOLO1693 1LAC The new VoltAlert 1LAC is for detecting control voltage from 24 V ac to 90 V ac e Fits in a shirt pocket for convenience e All outer surfaces are no
48. ironments and to 600 V for use in CAT IV environments T5 1000 only Accessories and Ordering Information Included accessories The T5 1000 and T5 600 come with detachable probes and instruction sheet The T3 has fixed test leads Optional accessories H5 Custom Holster for 5 and models Large Jaw Alligator Clips T5 only AC20 Industrial Test Clips T5 only Ordering information ServiceFirst Item Mfg Description 00854 T5 1000 1000 V voltage continuity and current tester TOLO1669 T5 600 600 V voltage continuity and current tester TOLO1689 13 Tester LED00389 648029 Replacement lead assembly for Fluke T5 meter RSP PRC018 EN ServiceFirst Fluke 1520 MegOhmMeter 0849 Fluke 1520 MegOhmMeter It takes a display this big to show you all the features The Fluke 1520 MegOhmMeter is a handy insulation resistance tester that also measures voltage and checks connections with its Lo Ohms function e Large backlit LCD with analog bar graph and digital display e Three output voltages for insulation resistance testing 250 V 500 V 1000 V e Insulation resistance testing up to 4000 MW switches automatically to voltage measurement when voltage 15 greater than 30 Vac 30 Vdc e voltage measurement up to 600 V e Lo Ohms function for testing connections e Last reading memory display e Four C cell batteries for up to 5 000 tests per EN61557 2 with battery lif
49. ket Thermometer with Laser Sight e Battery 2 CR2032 installed e Range 27 F 482 F e Accuracy 2 F or 2 73 F 10 F in lt 90 RH e Resolution 0 1 F e Operating Environment 32 F to 122 F e Field of View 3 1 TOLO1120 ST3 Dual temperature Thermometer e Great temperature compensation for fast changing environments e Select F or C e Thermocouples included MTROO0894 SRPM1 Optical Laser Tachometer rpm Meter e Measures rpm without contact e Laser light e Works to four feet e Range 2 5 to 99 999 rpm IVITROOS819 SMG5 Megohm Meter Low cost meter for checking compressor insulation e Predict compressor failure e 1000 Vdc stresses insulation to measure up to 2000 Mohms e Backlit LCD display e Auto off to extend battery life e Case alligator clip leads with removable tips 23 ServiceFirsr Accessories for Field Service E Fieldpie ah Description and Application The SMG5 provides 1000 V voltage source monitors current and displays the resistance between the test points Maximum current output is 1 mA It can be used to determine the condition of insulation from winding to ground in a motor compressor or transformer Disconnect the windings and measure the resistance between the windings and ground through the insulation Determine what a good reading is by comparing your reading to values supplied by the manufacturer of the eq
50. l oscilloscope e wo 5 000 count True rms digital multimeters e A dual input TrendPlot recorder e Connect and View trigger simplicity for hands off operation e Shielded test leads for oscilloscope resistance and continuity measurements e Up to five hours battery operation e 600 V CAT Ill safety certified e Optically isolated RS 232 interface e _ Rugged compact case One test lead measures all High frequency waveform meter capacitance and resistance measurements and continuity checks are all covered by the shielded test leads No time wasted finding or swapping leads Battery powered mobility Five hours of battery operation frees you from mains outlets for true on the move Dual input measurement shows i e both meter reading and waveform working Its handheld format weighing just 1 2 kg is easy to carry and it fits comfortably in your hand The rugged and drip proof case ensures long life and reliable operation in the harshest industrial environments Use TrendPlot to help find intermittents fast found in 123 and 190 The toughest faults to find are those that happen only once in a while intermittents They can be caused by bad connections dust dirt corrosion or simply broken wiring or connectors Other factors like line outages and sags or the starting and stopping of a motor can also cause a machine to stop You may not be around to see it Fluke s ScopeMeter 123 will In this paperle
51. ltimeter MTR00834 Fluke 179 Digital Multimeter Recommended Accessories 170 Series DMIVIs ServiceFirst Item Mfg Description KIT07904 TPAK Meter hanging kit with magnet CAS01261 25 Soft vinyl carrying case CAS01262 C510 Top grain leather carrying case CMP00956 i200 ac current clamp LED00358 TL23F Electrical test lead set Fluke 16 and 12 Series Multimeters The Fluke 10 Series models are designed to support basic electrical and electronic troubleshooting Their compact design slide switch and push button controls allow true one handed operation In addition to the features and functionality of the Fluke 12 the Fluke 16 incorporates temperature and microamps for flame sensor measurements Features ServiceFirst Item MTR00858 00872 MTR00831 Mfg Fluke 7 600 Fluke 12 Fluke 16 4000 Count Digital Display VCheck e Capacitance 1 000 10 000 uF Temperature Microamps e Min Max Record w Elapsed Time Clock Continuity Capture Diode Test e Fast Continuity Beeper VCheck 12 and 16 only simplifies safe power source and supply measurement When measuring ohms continuity with more than 4 5 volts present across the input jacks intentional or not the meter automatically switches to measuring ac or dc volts whichever is the greater Input impedance is approximately 2 kW helping determine if voltage is from leakage or a hard connection Overload protection is provided if the circuit is checked
52. lugs BNC termination Banana Plugs BNC termination BNC termination BNC termination Warranty 1 year 1 year 1 year 1 year 1 year 1 year Safety Rating CATIII 600 V CATIII 600 V CATIII 600 V CATIII 600 V Meter Compatibility Range Limitations 10 11 12 12B 16 18 1Ato 200A 0 1 A to 1000 A 2 Ato 2000A 21 23 73 75 77 Series 3 1Ato 200A 1Ato 200A 1Ato 400A 1Ato 600A 0 1 Ato 1000 A 2 Ato 2000 A 26 79 Series 3 1Ato40A 1Ato 200A 1 Ato 40 A and 1 Ato 40 A and 0 2 Ato 1000 A 2 Ato 2000 A 200 A to 400 A 200 A to 600 A 27 1 Ato 200A 1 Ato 200A to 400A 1Ato 600A 0 1 1000 A 2 Ato 2000 70 Series Ill 1 Ato 200A 0 1 A to 1000 s 2 Ato 2000 83 Series III 1Ato 200A 1Ato 200A 1Ato 400A 1Ato 600A 0 1 A to 1000 2 Ato 2000 A 85 87 Series III 1Ato 200A 1Ato 200A 1Ato 400A 1 A to 600A 0 2 Ato 1000 A 2 Ato 2000 A 87 89 Series IV 187 189 1 Ato 200A 1 Ato 200A to 400 A 1 A to 600 A 0 1 Ato 1000 A 2 Ato 2000 8060 8062 DMMs 1 A to 200 A 1 A to 200A 10 400A to 600 0 2 A to 1000 2 Ato 2000 860 Series Graphical Multimeter 1 A to 200 1 A to 200 A 1 A to 400 A 1 A to 600 A 0 3 A to 1000 A 2000 A 39 41B Power Meter 1Ato 200A 0 1 Ato 1000 A 2 Ato 1000 A 9X Series B ScopeMeter 1Ato 200A 0 1 Ato 1000 A 2 Ato 2000 123 ScopeMeter 1Ato 200A 0 25 A to 1000 A 2 5 Ato 2000 A 190 Series ScopeMeters 1 A to 200A 0 1 A to 1000 A 2 A to 2000 A 45 DMM 1 5 A to 100 A 1 A to 200 A 1 5 A to 100 A 1 5 A to 100 A and 0 15 Ato 1000 A
53. ly every electronic need e CAT Il 300 V 07902 TL20 Industrial Test Lead Set e Great for general purpose industrial applications e One pair each of TL22 test leads LEDOOS35S TL2S3F LEDOO387 TL23R Electrical Test Lead Set e Great for general purpose electrical applications e One pair each of TL24 test leads AC20 alligator clips and TP1 test probes TL23F or TP4 test probes TL23R e CAT Ill 1000 V 10 A CAT IV 600 V 10 A 49 ServiceFirst Current Clamps FLUKE o ac Current Clamps Specifications ServiceFirst Item CMP00956 CMP00974 CMP00952 CMP00966 CMP01025 CMP00968 Mfg i200 i200s 80i 400 80i 600A 80i 1000s i2000flex ac Current Range 1Ato 200A 1Ato 200A 1Ato 400A 1 A to 600A 0 1 A to 1000 A 2 A to 2000 A Accuracy Less than or equal Less than or equal 3 0 4 A 2 0 5 1000 A 2 1 of full to 390 0 5 to 3 5 0 5 0 1 10 A scale 3 100 mA Frequency Response 3dB 40 Hz to 40 kHz 40 Hz to 40 kHz 5 kHz 10 Hz to 50 kHz 5 Hz to 100 kHz 1 Hz to 20 kHz Maximum Conductor Diameter 0 8 20mm 0 8 20mm 1 18 30 mm 1 98 50mm 2 13 54mm 2 44 62mm Maximum Conductor Size 300 MCM 300 MCM 750 MCM 2 500 MCM 2 500 MCM 24 4 or 2 500 MCM or 1 1000 MCM or 1 1000 MCM circumference Output Levels 1 mA A 10 mV A 100 mV A 1 mA A 1 mA A 1 mV A 10 mV A 10 mV A 1 mv A 100 mV A Output Cable 1 5 m Shrouded Dual 2 meter to 1 5 m Shrouded 1 2 m Shrouded 1 6 meter to 2 3 meter to Banana P
54. n e LCD output e Manually scroll to see measurement time and sequence number e MIN MAX AVG button to automatically see min max and average of current data set e Record multiple data sets e Downloadable to computer software and cable included e Seven day battery life e Backlight e Tag the reading with the PARA meter function Add any three characters to the reading for future identification or sorting e Using the RECORD button you add a reading at any time e Low cost e Easy to use HLDOOSSO6 EHDL1 Electronic Handle Converts any Fieldpiece accessory head into a stand alone instrument e _ MIN MAX to record highest and lowest reading e Ranges 200 mVac 2000 mVac 200 mVdc 2000 mVdc e Resolution 0 1 mV e Accuracy 0 596 reading 1 digit e Accuracy 1 296 reading 3 digits 50 500Hz e Overload protection 30 or 24 Vac ADPOOS68 AHDL1 Accessory Head Adapter Connects any Fieldpiece accessory head to any digital multimeter with industry standard jacks RSP PRCO18 EN 7 ServiceFirst ae Heavy Duty for Field Service TOLOO305 HB74 Heavy Duty Digital Multimeter Heavy duty and ruggedized with all the necessary features for the field e Phase rotation function for correct connection of three phase power e Capacitance for motor start run capacitors High voltage warning LCD and beeper Microamps f
55. n 600V or AC rms e Transient protection 6kV for 10 sec ServiceFirst DC current Ranges 4001 4000 Resolution Accuracy 1 0 rdg 2 dgt Voltage burden 200mV 2V 40001 range Input protection 250mA 600V 6 3x32 mm fast blow ceramic fuse part number RFM66 Resistance Ranges 4000 4 A0kC2 400kC 4 40 Resolution 0 102 Accuracy 1 0 rdg 4 dgts on 4000 to 400 ranges 1 5 rdg 4 dgts on 4MQ range 3 0 rdg 5 dgts on 40M range Open circuit volts 0 45VDC typical 1 2VDC on 4000 range Overload protection 500VDC or AC rms Capacitance Range 400 Resolution Accuracy 0 3 rdg 5 dgts Input protection 250mA 600V 6 3x32 mm fast blow ceramic fuse part number RFM66 Frequency Ranges 4k 400k 4M 40MHz Resolution 1Hz Accuracy 0 1 rdg 3 dgts Sensitivity 10Hz 4MHz gt 1Vrms AMHz 40MHz gt 2Vrms gt 5Vrms Minimum pulse width gt 25ns Duty cycle limits gt 30 and lt 10 Overload protection 500VDC or AC rms 11 ServiceFirst rape oom Fieldpi ce Heavy Duty for Field Service Test Lead Solutions e Probe storage in the back Just snap them in e Removable probe tips for connection to most accessory heads e Attach detachable probe tip directly into jack for easy and safe voltage testing Silicone wire test leads remain flexible in cold weather withs
56. n Contact Volt Probe 00933 VP 600 MTRO0934 VP 600B IVITROO935 VP 600SB e Detect AC Voltage 100 600V e Use non contact method of Voltage testing e Totally insulated no exposed metal or conductive parts e Check for AC Voltages without necessity of disconnecting the electrical system e for AC Voltage cables circuit breakers wall sockets junction boxes fuses etc Features VP 600 VP 600B VP 600SB AC Voltage Detection 100 600V Voltage Light Voltage Buzzer Voltage Shaker TOLO1953 PRM 1 Phase Sequence and Motor Rotation Tester Features Low cost tester identifies 3 phase line sequence and motor rotation e Wide operating voltage and frequency ensures compatibility with most 3 phase circuits e Built in phase loss indicator prevents incorrect reading Specifications Operating voltage 20 to 60 VRMS Operating frequency 50 60 70 Hz Isolation 3000 Vac Operating temperature 32 F to 113 F 0 C to 45 C Storage temperature 40 F to 140 F 40 C to 60 C Power 9 V alkaline Amprobe model MN 1604 included Integrated test leads 18 45 72cm color coded Dimensions 3 75 2 625 1 5 9 53cm 6 67 x 3 81 0 Instruction sheet Part number 921751 included ServiceFirst Item Mfg Description 101953 PRM 1 Tool amprobe prm 1 phase sequence and motor rotation tester 67 A AMPROBE ServiceFirst Cross Reference ServiceFirst to Amprobe SF MTR008
57. nconductive for safety e Detects voltage without metallic contact e Manufactured printed and packaged in the U S CAT 111 600 V US and North America Other models available to accommodate various line voltages and wall outlets Not available in Australia and Sweden RSP PRC018 EN 37 ServiceFirst FLUKE o 38 Fluke T Series Electrical Testers Now you can get more from a tester Fluke T3 and T5 Voltage Continuity and Current Testers Fluke T3 Voltage and Continuity Tester Tests ac dc voltage and continuity Seven different voltage indicators clearly differentiate between key voltage levels Automatically switches to continuity beeper or ac dc voltage measurement mode Fits the optional H5 holster that clips onto your belt e Auto On light lets you know that it is working e Dc polarity indicator e Auto Off conserves battery power Protected to 1000 V for use in CAT Ill environments and to 600 V for use in CAT IV environments Fluke T5 Voltage Continuity and Current Testers Available in 600 V and 1000 V models to test ac dc voltage continuity and ac current The OpenJaw lets you check ac current to 100 A without breaking the circuit Fits the optional H5 holster that clips onto your belt e Detachable Slim Reach probe tips customized for national electrical standards e Displays resistance to 1000 ohms e Auto Off to conserve battery life Protected 1000 V for use in CAT env
58. ng battery life Access door for fast battery changes without breaking the calibration seal Specifications Function Range and resolution DC Volts 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V AC Volts 600 0 mV 6 000 V 60 00 V 600 0 V 1000 V DC Current 600 0 A 6000 pA 60 00 pA 600 0 mA 6 000 A 10 00 A AC Current 600 0 A 6000 pA 60 00 pA 600 0 mA 6 000 A 10 00 A 200 to 1090 C 328 to 1994 F 40 to 260 C 40 to 500 F Temperature excl probe 80BK Temperature Probe Resistance 600 0 Q 6 000 kQ 60 00 600 0 6 000 50 Capacitance 10 00 nF 100 0 nF 1 000 uF 10 00 uF 100 0 LF 9 999 uF Frequency 199 99 Hz 1 9999 kHz 19 999 kHz 199 99 kHz Ordering Information Mfg Fluke 83 5 Fluke 87 5 Fluke 87 5 E Basic accuracy 83V 87V 0 08 0 05 0 5 0 7 True rms 0 4 0 2 1 2 1 0 True rms 1 090 2 2 C or 295 0 4 0 2 1 0 1 0 0 0005 0 005 RSP PRC018 EN ServiceFirst Digital Multimeters IMTROO905 Fluke 123 Industrial ScopeMeter Test Tool ScopeMeter 123 Three in one simplicity The compact ScopeMeter 123 is the rugged solution for industrial troubleshooting and installation applications It is a truly integrated test tool with oscilloscope multimeter and paperless recorder in one affordable easy to use instrument Find fast answers to problems in machinery instrumentation control and power systems e A dual input 20 MHz digita
59. nrush Integration Time Poe A lt Hz Size 00832 00842 00847 MTR00846 MTR00836 Fluke 322 Fluke 333 Fluke 334 Fluke 335 Fluke 336 0 40 00 0 400 0 0 600 0 0 600 0 0 600 0 40 0 400 0 A 1 8 5 counts 2 5 counts 2 5 counts 2 5 counts 2 5 counts 50 60 Hz 50 60 Hz 50 60 Hz 50 60 Hz 10 100 Hz 105 oms woms Accuracy ac Response Range 4 4 600 04 Accuracy 0 400 0 V 0 600 0 V 0 600 0 V 0 600 0 V 0 600 0 V 400 600 V 1 2 5 counts 1 5 counts 196 5 counts 196 5 counts 196 5 counts 50 400 Hz 50 60 Hz 50 60 Hz 50 60 Hz 20 100 Hz 0 400 0 V 0 600 0 V 0 600 0 V 0 600 0 V 0 600 0 V 400 600 V Accuracy ac Response Accuracy 0 400 0 Q 0 600 0 Q 0 600 0 Q 0 600 0 Q 0 600 0 Q 601 6000 601 6000 601 6000 Q Accuracy 1 5 5 counts 1 5 5 counts 1 5 5 counts 1 5 5 counts Continuity Range BONN CENE CNN CREE MNMAX Ys Display Hol HxWxD 7 5 2 5 1 4 9 4 3 1 x 1 6 9 4 x 3 1 x 1 6 9 4 x 3 1 x 1 6 9 9 x 3 1 x 1 6 00843 Fluke 337 0 999 9A 2 5 counts 10 100 Hz True rms 100 mS 0 999 9A 2 3 counts 0 600 0 V 1 5 counts 20 100 Hz True rms 0 600 0 V 1 5 counts 0 600 0 Q 601 6000 2 1 5 5 counts lt 30 Q 5 400 Hz 0 5 5 counts Yes Yes Yes 9 9 x 3 1
60. nstruction with heavy duty stitching and reinforced rivets e Large tool belt loop and top flap to secure meter e Holds most Fluke thermometers and process calibrators CAS01285 C520A Leather Tester Case e Genuine top grain cowhide e Oil tanned for long life e Rugged construction with heavy duty stitching and reinforced rivets e Large tool belt loop e Enlarged case compartment to safely secure tester and leads e Holds Fluke electrical testers CAS01266 C550 Tool Bag e Steel reinforced frame e Rugged ballistic cloth with heavy duty hardware e Large zippered storage compartment with 25 pockets e Weather resistant e Carries all your tools to the job 501263 C12A Meter Case e Zippered carrying case with inside pockets and belt loop CASO1309 C20 Meter Case e Heavy duty case with carrying handle and accessories storage compartment e Top cover snaps onto back to serve as tilt stand CAS01261 C25 Meter Case e Zippered carrying case with padding and inside pocket CAS01268 C50 Meter Case e Zippered carrying case with inside pocket belt loop and inside meter strap CAS01273 C90 Meter Case e Zippered carrying case with inside pocket and belt loop 501271 501286 C781 C125 Meter Case e Zippered carrying case with detachable external pouch 55 ServiceFirst 56 FLUKE o Cases and Holsters 501272 C789 Meter and Accessory Case e Large fabric carrying
61. o 600 A ac 4 Ato 1000 A dc No ac 4 Ato 1000 A dc No ac 1 Ato 1000 A dc and 110 A to 600 A ac 1 Ato 1000 A dc and 20 A to 600 A ac 51 ServiceFirst FLUKE o 52 Temperature Accessories Hot Probes and Cool probes Contact Probes TCPOOO096 80PK 1 Bead Probes This basic inexpensive thermocouple offers good accuracy and fast response Not suitable for liquid immersion 80PK 1 is compatible with K type thermometers e Measurement range 40 to 260 C 40 to 500 F TOLO1687 SOPK 2A Immersion Probe Use as a general purpose probe including liquids and gels e Compatible with K Type temperature measuring instruments e Measurement range 40 to 982 C 40 to 1 800 F TOLO1686 80PK 3A Surface Probe Designed for measuring the temperature of flat or slightly convex surfaces this K type probe is ideal for hot rollers and plates e junction allows direct contact with the surface being measured e Measurement range 0 to 260 C 32 to 500 F 0099 80PK 4A Air Probe For air and non caustic gas applications e Probe constructed of 304 stainless steel with a perforated baffle around the measurement bead e Measurement range 40 to 816 C 40 to 1 500 F TOLO1688 80PK 5A Piercing Probes Designed for foods liquids and gels e Probe made of 304 stainless steel is compatible with K Type instruments e Measurement range 40 to 260 C
62. ode tests Capacitance For motor run and motor start capacitors Frequency HS35 For variable frequency drives And More e Rugged rubberized case with magnetic hanger Hr voltage indicators you can t miss both LED and beeper turn on to indicate you have touched a potentially dangerous voltage e Continuity indicated by LED and beeper e hold automatically holds reading so you can look at the meter after you have disconnected Low ohms ranges for motor windings and mid range for thermistors e Auto power off to extend battery life e UL Cat 600 V pending Remote Testing For hard to reach test points remove the probe tips and connect to ACH current clamp head Hanger For safe and easy testing hang the meter using the magnetic hanger For maximum safety clip one lead to ground and test with one hand 10 RSP PRC018 EN KITO9516 HS36 Specifications Display 334 digit liquid crystal display LCD with a maximum reading of 3999 Analog bar graph 41 segments with measurements 20 times per second Range RNG Manual ranging mode HS35 Overrange OL mark indication Auto power off 30 minutes Operating environment 32 F to 122 F at 7096 Storage temperature 4 F to 140 F 0 to 80 R H with battery removed Accuracy Specifications good in ambient conditions of 73 F 9 F lt 75 relative humidity Temperature coefficient 0 1x specified accuracy per F
63. on to indicate range and resolution using a single number For example number 40 00 indicates range of 40 and resolution 0 01 two digits after the point with the 1 as an increment unless otherwise specified Optional Accessories Part Number Alligator clips for test leads VRC 320 Replacement Parts supplied with number Part Number Test leads with set of alligator clips alligator clips not supplied with product MTL 90B Instruction manual www amprobe com ServiceFirst Item Mfg Description MTR00886 AM 33 Meter amprobe am 33 intelligent digital meter 600 V ac dc 400 ohms 65 ServiceFirst Amprobe 918 ACD 10 Pro MTROO915 ACD 14 MTROO925 ACD 10RMS Tech Clamp Digital Clamp on Multimeters e ACD 14 tech clamp specifically designed for HVAC R applications A AMPROBE e and dc voltage 600 V e ac current to 400 A 66 e Resistance 40 MQ with continuity buzzer e Capacitance to 3000 uF e Dual display ACD 14 only e Micro amps for testing flame sensors ACD 14 only e Temperature Type K thermocouple ACD 14 only e Frequency measurement Diode test e Hold and maximum reading functions e Accommodates conductors up to 1 02 26mm in diameter e Auto ranging e Auto power off and low battery indication Rubber over molded case Overload protected e Safety Cat II 600 V and Cat IIl 300 V e 600 V ACD 14 only e CE approved UL listed Feature
64. or flame rectifier diode circuit e Amps to 10 through meter to 300 Aac with clamp Frequency for variable frequency motor drives Built to withstand use and abuse of the field e MOV transient protection e Valox housing e ring seals and gaskets to keep contamination out High voltage fuses e Rubber holster TOLOO319 LT83 Good Meter Great Price e Volts ohms amps continuity e Works with all Fieldpiece accessory heads using optional ADLS2 leads or AHDL1 handle adapter e Microamps for flame safety diode test e MAX hold MTR00856 LT17B Biggest Bang for the Buck in HVAC R Features and functions designed for HVAC R e Temperature K type thermocouple plugs directly into meter No adapter to lose e for motor start run capacitors e Microamps for flame rectifier diode tests e Low ohm ranges for motor windings e Medium ohm ranges for thermistors as well e Frequency for variable frequency drives 00855 LT16B True RMS Meter For Motor Installation and Service Has functions and ranges often needed when working with motors e Volts ohms continuity and amps e Phase rotation indicator for 3 phase motor connection e Frequency for variable frequency drives e for motor start run capacitors RSP PRC018 EN RSP PRC018 EN Heavy Duty for Field Service Specifications HB74 LT16B LT17B HVAC Digital Multi Meters Function Range Vac 20
65. perature head For air temperatures only use the ARH3 ARH4 You can also measure other air parameters with them such as RH and wet bulb For comparing input and output temperatures pipe temperatures or other contact temperatures use the ATH4 When it is not practical to touch the test point a ceiling vent for example use the ATIR3 infrared head Infrared is not recommended for accurate pipe temperatures 00676 ARH3 Temperature and RH Head Measures air temperature and RH e _ 1 50 F 113 F e 2 5 RH 10 to 90 RH 77 F Select F or C e Auto off can be disabled for data logging 00661 ARH4 Wet Bulb and Dew Point Head Measures air temperature and RH and displays wet bulb and dew point 19 32 F 113 F e 2 5 RH 10 to 90 RH 77 F Select F or C e Auto off can be disabled for data logging 00689 ATH4 Dual Temperature Head Two k type thermocouple inputs Display T1 T2 or T1 T2 e Field calibration for 1 F accuracy e Displays F directly at 0 1 F resolution on DMM with 0 1 mVdc resolution Select F or C e Converts from 50 F to 1800 F optional thermocouple required e Includes two wrap tab thermocouples plus velcro straps Thermocouples insulated to 400 F e Auto off can be disabled for data logging 00681 ATIR3 Non contact Infrared Surface Temperature Head with Laser Sight Measures temperature witho
66. rrent sourcing Range 0 20 mA or 4 20 1 Accuracy 0 015 reading 2 LSD Drive capability 12000 24 mA Loop power while measuring mA 24 Voltage sourcing N A Resistance measurement N A Frequency N A Diode test N A Continuity N A Display current and of span Yes Auto step auto ramp Yes Span check Yes Battery life 18 hours typical at 12 mA 1 Will over range to 24 mA Accessories and Ordering Information Included accessories C 10 Protective Yellow Holster TL75 Test Leads AC70 Test Clips Instruction Sheet 14 languages RSP PRC018 EN RSP PRC018 EN 07 0 1 ij ServiceFirst Test Leads Probes and Clips Modular leads and probes LED00363 TL21A Test Lead Extension e 1 5 meter long silicone insulated test leads with shrouded male connectors both ends e Separate female couplers convert the test leads into lead extensions e CAT Ill 1000 V 10 A CAT IV 600 V 10 A LEDOO359 TL22 Silicone Test Leads e Flexible silicone insulation is heat and cold resistant e 1 5 meter long leads have shrouded right angle connectors both ends e CAT III 1000 V 10 A CAT 600 V 10 A KITO7903 TL24 Silicone Test Leads Flexible silicone insulation is heat and cold resistant e 1 5 meter long leads have a shrouded right angle connector on one end and shrouded straight connector on the other e CAT Ill 1000 V 10 A CAT IV 600 V 10 A LEDOOS364 1127 Hea
67. s ac voltage dc voltage ac current Resistance with continuity buzzer Capacitance Frequency Using jaw or test leads ACD 10 Pro 4 000 V 40 00 V 400 0 V 600 V 0 400 0 mV 4 000 V 40 00 V 400 0 V 600 V 0 40 00 A 400 0 0 400 0 Q 4 000 k 2 40 00 400 0 0 4 000 40 00 ACD 10 TRMS Pro 4 000 V 40 000 V 400 0 V 600 V 0 400 0 mV 4 000 V 40 00 V 400 0 V 600 V 0 40 00 A 400 0 A 0 400 0 2 4 000 k 2 40 00 400 0 0 4 000 40 00 500 0 nF 5 000 pF 50 00 uF 500 0 uF 3000 uF 500 0 nF 5 000 50 00 uF 500 0 uF 3000 F 40 400 Hz with jaw 10 Hz to 2 kHz with test leads TRMS Measurement NA Features TRMS measurement ac voltage dc voltage ac current ac dc micro amps using test leads Resistance with continuity buzzer Capacitance Frequency Using jaw or test leads Temperature ACD 10 Pro N A 4 000 V 40 00 V 400 0 V 600 V 0 400 0 mV 4 000 V 40 00 V 400 0 V 600 V 0 40 00 A 400 0 A N A 0 400 0 Q 4 000 40 00 400 0 kQ 0 4 000 MQ 40 00 MQ 500 0 nF 5 000 uF 50 00 uF 500 0 uF 3000 uF 40 400 Hz with jaw 10 Hz to 2 kHz with test leads N A 40 400 Hz with jaw 10 Hz to 2 kHz with test leads Yes ACD 14 Accuracy N A 4 000 V 40 000 V 1 5 of reading 5 LSD 400 0 V 600 V 4 000 V 40 00 V 400 0 V 0 400 0 4 000 V 40 00 V 400 0 V 600 V 0 40 00 A 400 0 A 400 0 pA 2000 pA 0
68. s add 1 per Insulation Resistance Measurement Test Voltage dc Range Accuracy reading 250V 200 kQ to 5 GQ 5 5 GQ to 50 GQ 20 500 V 200 kQ to 10 GQ 5 10 GQ to 100 GQ 20 1000 V 200 kQ to 20 GQ 5 20 GO to 200 GO 2096 2500 V 200 kQ to 50 GO 5 50 GQ to 500 GQ 20 5000 V 200 kQ to 100 GQ 5 100 GQ to 1 TQ 20 Short circuit current Greater than 1 mA and less than 2 mA Bar graph range 0to1TQ Insulation test voltage accuracy 096 to 1096 at 1 mA load current Induced ac mains current rejection 2 mA maximum Charging rate for capacitive load 5 seconds per RSP PRC018 EN RSP PRC018 EN ServiceFirst Fluke 1550B MegOhmMleter Function Range Accuracy Leakage current 1 nA to 2 mA 5 2 nA Capacitance measurement 0 01 uF t 15 00 uF 15 reading 0 03 pF Live circuit indicator 30 V to 600 V ac dc 50 60 Hz 5 2 V Timer 0 to 99 minutes settable in 1 minute increments indicated to within 1 second Ramp 0 to 100 of selected test voltage or until breakdown Mechanical Specifications Dimensions H x W x L Weight with battery Power Battery type Charger input ac Charger input Environmental Specifications Operating temperature Storage temperature Relative humidity Operating altitude Enclosure sealing Safety Input overload protection Software Specifications 330 mm x 242 mm x 170 mm 13 in x 9 5 in x 6 7 in 4 kg 8 8 Ib 12 volt lead acid rechargeable 85 to 250
69. signals Stand alone data recording Hang meter for hands free usage more informaion on safety ratings please see application note ABCs of Multimeter Safety available for viewing or download from www fluke com NMTROOS34 Fluke 179 Designed to meet the demands of the industrial professional Features ServiceFirst Item Maximum display digits Display digit size Backlight Fused current inputs Best basic accuracy Frequency Capacitance Temperature Maximum ac voltage Warranty Latest safety standards Optional ToolPak magnetic hanging strap Old Fluke 23 27 3 200 Standard No No 0 30 No No No 750 3 years No No NEW Fluke 179 MTR00834 6 000 20 larger Yes Yes 0 09 Yes Yes Yes 1000 Limited lifetime Yes Yes Benefits Greater resolution Easier to read Usable in dark workspaces Better protection Three times more accurate More functionality More functionality Built in thermometer Extended ac range Lower cost of ownership 1 000 V CAT Ill 600 V CAT IV Hang meter for hands free usage more informaion on safety ratings please see application note ABCs of Multimeter Safety available for viewing or download from www fluke com 35 ServiceFirst 36 FLUKE o Multimeter Transition Guide MTROOSS3S Fluke 112 Durable compact meter for installers and contractors Features ServiceFirst Item True rms Maximum display counts Backlight
70. software make it ideal for preventive maintenance Heavy duty leads probes and alligator clips fit in the custom carrying case for a rugged field testing kit e Standard test voltages of 250 500V 2500V and 5000V e Programmable test voltages available in 50 volt steps from 250 to 1000 volts and 100 volt steps from 1000 to 5000 volts e Automatic calculation of Dielectric Absorption and Polarization Index with no additional setup e Improved ramp function 0 5000V dc for breakdown testing e Measures resistances up to one teraohm e Measures cable or insulation capacitance and leakage current e Warning voltage function alerts the user that voltage is present and gives the voltage reading up to 600V ac or dc e Guard system eliminates the effect of surface leakage current on high resistance measurements e Measurements can now be stored in up to 99 memory locations with each location assigned a unique user defined four character alpha numeric label for easy recall e Improves improved Quicklink 1550B Software and Optical Interface cable for easier downloading to a Windows PC e Runs off of high capacity rechargeable batteries e Two year warranty Specifications Electrical Specifications The meter s accuracy is specified for one year after calibration at operating temperatures of 0 C to 35 C For operating temperatures outside the range 20 C to 0 and 35 C TO 50 C add 25 per C except on the 20 band
71. ss recorder mode you can plot the minimum and maximum peak values and average Y the S Meter 123 io check cepaciance of over time up to 16 days The two inputs can plot any combination of volts amps temperature frequency and phase with time and date stamp to help lead you to motor the cause of those faults quickly Safety conformance The ScopeMeter 123 and the included shielded test leads are safety certified for measurements on 600 V CAT Ill industrial power systems the optically isolated RS 232 interface the ScopeMeter 123 can be safely connected to a printer for direct printout or a PC for later analysis and documentation with FlukeView software Cursors zoom featured by the 190 Series help you to analyze the captured TrendPlot RSP PRC018 EN 33 ServiceFirst 34 FLUKE o Digital Multimeters 914 Fluke 88 Deluxe Automotive Multimeter The Fluke 88 is a complete automotive diagnostic package It offers virtually everything you need in an automotive multimeter Volts ohms amps continuity and diode test Milliseconds pulse width measurements measurements with inductive pickup Min max avg recording Frequency and duty cycle measurements Lo Ohms function Change Alert Smoothing Bright white backlit display Rugged hard shell carrying case Deluxe test leads with interchangeable test probes and wide jaw alliga
72. tand caustic chemicals and work well in temperatures that will melt vinyl leads e Leads conveniently wrap around meter Function Range Ranging Counts Bargraph Vac 200m 2000m 40 200 600 Vdc 200m 2000m 20 200 600 AAC 200 ADC 400u 4000 F 200 F 1000 F MFD 200 Hi V indi gt 30 V NCV gt 24 Vac Ohms 200 4K 40K 200K 4M 20M Continuity Diode HZ A With ACH clamp head B Beeper C LED and beeper D Range is 40xx instead of 20xx Accuracy Resolution Manual 1 2 3 0 1 1 2 3 1 1 2 3 0 01 1 2 3 0 1 2 5 1 0 5 1 0 1m 0 5 1 1m 0 5 1 0 01 0 5 1 0 1 0 5 1 1 2 5 2 1 1 0 1p 1 1 1 1 F 0 1 1 F 1 3 5 0 1 1 4 0 1 1 4 1 1 4 10 1 4 100 1 5 4 1K 3 5 10K B HS32 Manual 2000 gt gt lt X HS33 Auto 2000 gt X gt lt X O OJ x HS35 4000 RSP PRC018 EN RSP PRC018 EN ServicFirst Accessories for Field Service Use your digital multimeter data logger or handle to measure parameters needed by HVAC R technicians Fieldpiece accessories work with meters that have mV ac and dc ranges and industry standard input jacks Use the Fieldpiece deluxe test leads or the convenient AHDL1 adapter handle to connect any accessory head to most digital multimeters For most heads set your meter to mVdc and read the LCD directly Which tem
73. ted DMM Temperature Probe Compatible with the Fluke 16 and Fluke 89 Series IV and other DMMs with temperature measurement functions e K type thermocouple with standard banana jack e Convenient one piece construction e Measurement range 40 C to 260 C 40 F to 500 F RSP PRC018 EN 53 ServiceFirst 54 FLUKE o Temperature Accessories Non Contact Probes TOLO1690 SOT IR For quick non contact temperature measurement in less than one second e Instantly measures temperatures from 18 C to 260 C 0 to 500 F e Highly repeatable readings displayed C or F e Optical resolution 4 1 e Output 1 mV C or 1 mV F switch selectable Other Temperature Accessories TCPOO101 80CK M Mini Connectors e Isothermal screw terminal for or J e Suitable for up to 20 gauge thermocouple wire e Color coded to industry standards K yellow J black e Two per package ADP00977 SOAK Adapts Type K thermocouple mini connector to dual banana plug inputs e Allows the Fluke 89 IV or Fluke 16 multimeters be used with any K type thermocouple accessory e Measurement range and accuracy is not affected by the 80AK adapter RSP PRC018 EN RSP PRC018 EN ServiceFirst Cases and Holsters Meter Cases A premium meter deserves a premium case CAS01262 C510 Leather Meter Case e Genuine top grain cowhide e Oil tanned for long life e Rugged co
74. ter 39 Fluke 1550B MegOhmMleter 40 Fluke 320 330 Clamp Meters 42 Carbon Monoxide Gas Measurement 43 Fluke 50 Series ll 44 Digital Thermometers 45 Loop Calibrator ipie dx RE TOR RON ROO C DON S 46 Test Leads Probes and Clips 47 Modular Leads 47 Modular Test 2 47 48 2004 American Standard Inc All rights reserved Pushmon CIPS 49 Test Lead Sets siss sinu 49 Current Clamps 50 Temperature Accessories 52 Hot Probes and Cool Probes 52 Temperature Probe 58 Non contact Probes uae imi dei pmo E ud ERR SEM 54 Other Temperature Accessories 54 Cases and Holsters 55 Meter Cases siss ga 55 FIOISIGES 56 Miscellaneous Accessories 57 Pressure
75. tor clips Sleep mode 10 Megohm input impedance Lifetime warranty Cat 11 300 V RSP PRC018 EN RSP PRC018 EN ServiceFirst Multimeter Transition Guide Replace the old with the new Move up to superior safety and technology MTR00840 Fluke 189 Full featured meter for the most demanding users Features ServiceFirst Item Maximum display digits Backlight Best basic accuracy Maximum current input Frequency range Maximum ac voltage Dual display PC interface Built in memory Warranty Latest safety standards Capacitance Duty cycle Temperature Min max avg Fast min max ac dc measurements Logging Optional ToolPak magnetic hanging strap Old Fluke 8060A 8062A 20 000 No 0 040 2 amps 100 kHz 750 No No No 1 year No No No No No No No No No NEW Fluke 189 MTR00840 50 000 Yes 2 levels 0 025 10 amps 1 MHz 1000 Yes Yes Yes Limited lifetime Yes Yes Yes Yes Yes Yes Yes Yes Yes Benefits More resolution for more sensitive measurements Usable in dark workspaces More accurate Extended range Extended range Extended ac range Display 2 readings at once Transfer readings for analysis Store readings internally Lower cost of ownership 1 000 V CAT Ill 600 V CAT IV More functionality More troubleshooting capabilities Built in thermometer Capture intermittent events Capture fast intermittent events Measure composite
76. uipment or from your own experience Noticing decreasing insulation resistance levels can forecast problems before catastrophic failure Why a DMM often is not enough To test resistance a DMM supplies low voltage 1 V to the test points and is capable of delivering only a few milliamps It is not a high enough voltage to detect high resistance problems that might indicate moisture and other contaminants and it is not enough current to measure lower values of resistance Accessories for Field Service Fuses ServiceFirst Item Mfg Description FUS01137 RFL701 1 Fuses 20 A 600 V 10 x 38 mm HB74 FUS01514 RFM66 4 Fuses 4 0 25 A 700 V 6 x 32 mm SC66 SC76 06118 RFM74 4 Fuses 4 0 5 A 500 V 6 35 x 32 mm HB74 LT17 KIT06119 RF 16 4 Fuses 4 0 1 A 250 V 5 x 20 mm LT16 LT17 06120 RFL83 4 Fuses 4 10 A 600 V 6 35 x 25 4 mm LT83 06121 RFM70 4 Fuses 4 2 A 600 V 6 35 x 25 4 mm LT6 LT16 06122 RFS74 4 Fuses 4 0 5 A 250 V 5 x 20 mm HB74 LT83 RSP PRC018 EN RSP PRC018 EN Cross Reference ServiceFirst ServiceFirst Item to Fieldpiece SF ADP00826 ADP00868 CAS00809 CAS00810 CAS00812 500814 501301 501302 CMP00820 CMP00821 CMP00876 FUS01137 FUS01514 FUS01536 HED00489 HED00495 HED00529 HED00648 HED00650 HED00661 HED00676 HED00678 HED00681 HED00682 00689 00695 HED00696 00780 HLD00886 06114 0
77. ultimeter with industry standard jacks to measure up to 40 kVdc or peak ac or 28 kV rms ac e Divides voltage measured 1000 e DCV accuracy 1 to 20 KV 2 to 40 KV e ACV accuracy 5 type at 60 Hz 19 ServiceFirsr Accessories for Field Service E Fieldpiece Easily carry what you need to the job site No more winging it or long walks back to the truck Case designs make instrument access fast If your area does not use gas just delete the at the end of a Fieldpack s part number to delete the manometer AMN2 and carbon monoxide ACM3 heads TOLO1919 DL2K13 TOLO1920 DL2K13G Includes along with the DL2 data logger all appropriate accessory heads thermocouples and test leads for comprehensive HVAC R testing and data logging Easily gather the complete story of a system upload to your PC and print out for hard copies of data TOLO1921 HB74K27 TOLO1922 HB74K27G This is a fully loaded kit with a heavy duty meter TOLO1913 HS33K14 TOLO1914 HS33K14G Compact kit that contains the most popular heads along with the manual ranging HS33 stick meter in a mid size convenient case TOLO1915 HS35K19 TOLO1916 HS35K19G Includes the most popular heads and accessories along with the autoranging HS35 meter in a briefcase style case that has plenty of room for hand tools or more instruments TOLO1917 HS35K31 HS35 plus dual alligator clips premium pipe clamp ARH4 R
78. urved jaw opens 20 mm e CAT Ill 600 V 10 A CLPOO965 AC89 Heavy Duty Insulation Piercing Clip e Plunger style safety grip operation with insulated jaws e Small pin pierces 30 10 14 AWG insulated wire e CAT Ill 1000 V 5 CAT IV 600 V 5 A CLPOO966 AC87 Heavy Duty Bus Bar Clips e Plunger style safety grip operation with insulated right angle jaws e Adjustable jaws open to grip flat bus bars or round conductors e CAT IIl 600 V 5 A RSP PRC018 EN RSP PRC018 EN Fi ij E p H 44 4 i 4 ServiceFirst Test Leads Probes and Clips Push on Clips for use with TL71 and TL75 test lead and probe sets CLP00983 AC72 Alligator Clips Slide on style for test probes e Gold plated jaws open to 8 mm e CAT Ill 600 V 10 A Test Lead Sets LEDOO360 TL71 Premium DMM Test Lead Set Flexible silicone insulated leads are heat and cold resistant e Distinctive comfort grip probes e Recommended for measurements e CAT Ill 1000 V 10 A CAT IV 600 V 10 A 07901 1175 Hard Point Test Lead Set e Extremely hard alloy tips resist wear e Distinctive comfort grip probes e Economical PVC insulated leads e CAT Ill 1000 V 10 A CAT IV 600 V 10 A LEDOO361 TL81A Deluxe Electronic Test Lead Set e 22 set with quadfold pouch e Everything in the TL80A plus pincers clips leads and adapters for virtual
79. ut contact e 8 1 field of view e Laser sight included Select F or C e Operating ambient temp 32 F to 122 F at lt 5 RH e Temperature measurement range O F to 752 F e Accuracy Whichever is greater At 73 F 10 F at lt 90 RH 2 0 reading or 32 F to 160 F 3 0 reading or 5 5 F O F to 31 F 161 F to 752 F 13 ServiceFirsr Accessories for Field Service 00696 AAV3 Air Velocity with Temperature Head Measures air velocity Use to estimate CFM Does not replace a hood for precision CFM measurements Air velocity e Ft min meters sec MPH KM hr e Range 80 to 5900 ft min e Accuracy 3 fs 1 digit Temperature e Displays F and e Range 4 F to 140 F e Accuracy 1 F from 32 F to 113 F e Resolution 0 5 F e Max operating temp 120 F e Output 1 mV unit of measure 1 mV 100 ft min above 2000 ft min 00648 2 Manometer Pressure Head Measures gas pressure and has resolution low enough for static pressure e Maximum 20 WC water column for gas pressure e 0 01 WC resolution for static pressure e Manual zero set for comparing two pressures e Includes tube and adapter for gas pressure measurement e Auto off can be disabled for data logging 00780 AVG2 Vacuum Gauge Accessory Head Sensor Precision thermistor e Fitting Standard flared brass fitting male e Range 50 to
80. vy Duty Test Leads e Rugged EPDM insulation e 1 5 meters long with shrouded straight connectors and excellent strain reliefs on each end e CAT Ill 1000 V 10 A CAT IV 600 V 10 A Modular Test Probes for use with modular test leads TOLO1685 TP1 TOLO1743 TP2 Slim Reach Test Probes e Slender probe bodies for probing closely spaced or recessed points TP1 has a flat blade ideal for electrical wall sockets TP2 has 2 mm diameter tip for precise electronic probing e CAT IIl 1000 V 10 A CAT IV 600 V 10 TOLO1670 TP20 Industrial Test Probes e Extra long tip ideal for probing recessed points e Sharp tip useful for piercing insulation e CAT Ill 1000 V 10 A CAT IV 600 V 10 A 47 ServiceFirst FLUKE o 48 y p Test Leads Probes and Clips Modular Clips for use with modular test leads 954 AC20 Heavy Duty Alligator Clips e Plunger style safety grip operation e Insulated jaws open to 20 mm e CAT Ill 1000 V 10 A CAT IV 600 V 10 A 955 80 Heavy Duty Hook Clips e Plunger style safety grip operation e Hook opening is 10 mm x 2 mm e CAT Ill 1000 V CAT IV 600 V CLPOO963 AC83 Heavy Duty Pincer Clips e Plunger style safety grip operation e Flexible shaft is 100 mm long e CAT Ill 1000 V CAT IV 600 V CLPO0964 AC85A Large Alligator Clips e Insulated banana jack style C
81. warranty Includes DMM cable KITO7921 CO 205 Aspirator Kit Allows flue gas samples up to 370 C 700 F to be drawn with the CO 210 or CO 220 for carbon monoxide measurement 1 year warranty Accessories and Ordering Information Carbon monoxide gas measurement Included accessories 210 C50 case battery cord to plug into digital meter and instruction sheet 220 C50 case battery and instruction sheet Ordering information ServiceFirst Item Description 10101692 CO 210 Carbon Monoxide Probe 00837 220 Carbon Monoxide Meter KIT07921 205 Aspirator 43 ServiceFirst FLUKE o Fluke 54 Series Ill 44 Fluke 52 Series Ill The Fluke 50 Series I Laboratory accuracy in rugged handheld thermometers Fluke 50 Series ll features Laboratory accuracy 0 05 0 3 e Large backlit dual display presents all the information you need at a glance e MIN and AVG with time references captures major events e Electronic Offset function maximizes overall accuracy by allowing you to compen sate for thermocouple errors e Supports a wide range of thermocouple types e Temperatures displayed in C F or Kelvin e Splash and dust resistant case design e Holster enhances ruggedness e Thermometers tested to withstand a one meter drop e User friendly front panel that is easy to set up and operate e Sleep mode to increase battery life typic
82. x 1 6 1 7 Models 321 322 Operating temperature 14 F to 122 F 10 C to 50 C Altitude 2 000 meters Battery life 2 AAA carbon zinc approximately 100 hours continuous automatic low battery indicator Safety rating IEC 1010 2 031 600 V CAT Temperature de rating lt 18 C gt 28 C add 0 1 x specified accuracy Storage temperature 22 F to 140 F 30 C to 60 C Models 333 334 335 336 amp 337 Operating temperature 14 F to 122 F 10 C to 50 C Altitude 2 500 meters Battery life 2 AA alkaline approximately 150 hours continuous automatic low battery indicator Safety rating 1010 2 031 600 V CAT Temperature de rating Add 0 1 x specified accuracy for each C above 28 C or below 18 C Storage temperature 40 F to 140 F 40 C to 60 C 42 RSP PRC018 EN RSP PRC018 EN ServiceFirst Carbon Monoxide Gas Measurement IITROOS837 CO 220 Carbon Monoxide Meter The CO 220 Carbon Monoxide Meter makes it easy to take quick and accurate measurements of CO levels A large backlit LCD display shows CO levels from 0 to 1000 ppm The MAX hold function stores and displays the maximum CO level 1 year warranty TOLO1692 CO 210 Carbon Monoxide Probe As an accessory to a digital multimeter with dc mV inputs the Fluke CO 210 measures CO levels from 0 to 1000 ppm As a stand alone device the LED indicator and beeper trigger with increasing frequency as the CO level rises 1 year