Home
3•1 - Process Partner AS
Contents
1. ow wemuwemm _ LE wesem EN www E ammen _ ae m m rema 7 Mn EE HER INDUSTRY Photolonization Detector PID Reference Chart 10 6 eV lamp Acetaldehyde Acetic acid Acetic anhydride Acetone Acrolein Acrylamide Allyl alcohol Allyl chloride Allyl glycidyl ether Allyl propyl disulfide Amino pyridine Amyl acetate Aniline Benzene Benzyl chloride Bromoform Butadiene Butoxyethanol Butyl acetate Butyl alcohol Butyl mercaptan Butylamine Butyl glycidyl ether Butyl toluene Camphor vapor Carbon disulfide Chloroacetaldehyde Chloroacetophenone Chlorobenzene Chloromethyl methyl ether Chloronitropropane Chloroprene Chrysene Cresol Crotonaldehyde Cumene Cyclohexane Cyclohexanol Cyclohexanone Cyclohexene Cyclopentadiene Di ethylhexyl phthalate Diacetone alcohol Diazomethane Dibutylphthalate Dichlorobenzene Dichloro ethyl ether Dichloroethylene Dichlorvos Diesel Diethylamino ethanol Diethylamine Diglycidyl ether Diisobutyl ketone Diisopropylanmine VOLATILE ORGANIC COMPOUNDS DETECTED BY A PID Dimethylamine Dimethylaniline Dimethylformamide Dimethylhydrazine Dimethyloacetamide Dimethylphthalate Dinitrotoluene Dinitro cresol Dinitro analine Dinitro benzene Dioxane Diphenyl Dipropylene glycol methyl ether Epichlorohydrin Ethanol
2. 18101741 KIT CYL 25 LEL Hexane E poo tose 18102249 CYL 40 LELHexane 8k CGA 600 fitting _ 18107987 CYL 500ppmHexane Pf tose CYL 25 LEL Hydrogen PY w CGA fitting 18100461 CYL 50 LEL Hydrogen 600 fitting iset et 18102905 CYL 560ppmHydrogen o aa 18103945 CYL 100 ppm Hydrogen CGA 600 fitting 712998 et _ Lo pod 2 18102154 CYL 10 ppm Hydrogen Chloride 58L 12 18102149 KIT abet Oo atone nn E E 00 RR RR 18100842 KIT 18102988 CYL 40 ppm Hydrogen Sulfide O 18102245 CYL 50 ppm Hydrogen Sulfide 10 O o 8E gt 18102304 CYL 125 ppm Hydrogen Sulfide FT 88 2202 18105809 CYL 10 ppm Isobutyene oo fed fro gt 18106591 CYL 100 ppm Isobutylene 600 fitting 18104554 CYL 500 ppm Isobutylene o tose 18100206 CYL 1 Methane 110801 20 Mettene 2 CYL 2 0 Methane 4 18100214 CYL 2 5 Methane 34L UU cs Us UN n RN p1088 y 8k faluminum gt NOTE Calibration gas cylinder expiration times vary due to gas type contact Industrial Scientific for detailed information Calibration Gas Cross Reference Chart Mim O 5LPM 0 1 Demand Flow Regulator Demand Flow Regulator w
3. Zone 1 IEC 60079 18 Objects greater than 50 mm Vertically dripping water Objects greater than 12 mm 75 to 90 dripping water in Production Control Stage 3 for Zone 2 or 22 AEX Class I Zone 1 FM 3600 ISA 12 16 01 Objects prestat than min 522 Zone 1 EN 50 015 Edita Groups irer mines Objects greater than 1 mm Splashed water il for other thai nike Ex o Zone 1 IEC 60079 6 Dust protected Water jets Dust tight Heavy seas I S Output Also shall comply with ISA 12 00 01 Based on ISA 12 02 01 Effects of immersion A indefinite immersion wn C EE 5 Approximate U S Enclosure Type Equivalent to IPXX Classification of Gases and Vapours into TA EXPLOSION GROUPS and 35 54 6and6P 67 ATEX Atmosph re Explosible 4 4X 55 12 and 12K 52 CENELEC Furopean Committee for 5 52 13 54 Electrotechnical Standardization EU European Union _ IEC International Electrotechnical Commission Ethanol Benzene Acetylaldehyde l S Intrinsically Safe Ethane i Amyl acetate Dieselfuel Ethylether MSHA Mine Safety and Health Administration Ammonia n Butane Aircraft fuel NEC National Electric Code Benzol pure n Butyl alcohol Heating oil Acetic acid n Hexane Methane natural gas Methanol Propane Coal gas Ethylene lighting gas Ref FM Approvals Expert Guide to Hazardous Locations 2004 FM Global
4. Regulator Regulator iGas Pressure Switch PART 4 DESCRIPTION 18100883 18100933 18102509 18103564 18105841 18105866 VOL NOTES CYL 10 LEL Methane dg o 34 w CGA600fiting ee MNA A 18105106 CYL 1 000 ppm Methane wCGA600 fitting 18102244 CYL 100 Nitrogen 18102248 CYL 100 Nitrogen eo fitting _ en aluminum Hn EA Dio aluminum 18102219 CYL 5 ppm Nitrogen Dioxide 18102238 KIT 18106252 CYL 10 ppm Nitrogen Dioxide 18105452 CYL 25 ppm Mogen Dioxide aluminum 18101469 KIT ERES 1 18102150 KIT JCGA 600 fitting S 600 fitting CYL 12 LEL Pentane cd GN S ee 18101261 KIT 2 vines 340 aumnum metam ME 18107797 Cyl 5PPMPhosphine fag poo poo J 8 2 18107805 Cy SPPMPhospine o poo Jf gt 18100164 CYL 25 LELPropane PJ poo wCGA600 fitting CYL 25 LEL Propane 18100172 CYL 50 LELPropane 1 W CGA 600 fitting 18104992 CYL 5 ppm Sulfur Dioxide 34L aluminum _ 18102239 KIT PP 18101212 18105726 CYL 100ppmTolulene pg e 34L w CGA 600 fitting CYL Zero Grade Air 20 9 Oxygen LE iG 600 fitting 18101584 CYL Zero Grade Air 20 9 Oxygen S C S tose tn Regulator Regulator Regulator Pressure Swi
5. AUDIBLE ALARM Buzzer RELAYS 2 gas alarm relays per channel One common relay for faults Type of contact N O or N C programmable by jumpers IP RATING IP 66 BRIDGE TYPE DETECTOR CONNECTION 1 detector maximum distance 300 m 3 x 1 5 mm 2 detectors utilization of a junction box Please consult us DETECTOR CONNECTION WITH TRANSMITTER One to five 2 wire detectors 4 20 mA One 3 wire detector 4 20 mA Cable 3 x 1 5 mm 32 max in loop mode FIRE DETECTOR CONNECTION One to five detectors cable 2 x 0 65 mm FLAME DETECTOR CONNECTION One 3 wire detector Cable 3 x 1 5 mm 4 8 max in loop mode WEIGHT 1 75 kg 3 86 Ib OPERATING TEMPERATURE 20 C to 55 C 4 F to 131 F RELATIVE HUMIDITY 5 to 95 RH APPROVALS Complies with EMC and low voltage directives ORDERING INFORMATION PART DESCRIPTION W321221 MX32 for Industrial Applications 2 channels 230 VAC W32022 32 for Industrial Applications 2 channels 230 VAC European Version 321211 MX32 for Industrial Applications 2 channels 110 VAC B103829 Wall Mount Battery Backup System uninterrupted power supply 289 x 350 x 189 mm for MX32 and MX42 Charger 24V 3 A Batteries 7 Ah SPECIFICATIONS 3 25 1 Analog input channel 3 On board relays LED and audible alarms Continuous self test e Control to 5 detectors SPECIFICATIONS DIMENSIONS 18 5 cm x 15 7 cm x 6 7 cm 7 28 x 6
6. Instruments are connected to DS2 Docking Stations Docking Stations perform bump tests calibrations and record keeping send data to iNet over the Internet INET REPORTS ENSURE A SAFER WORKPLACE iNet s data collection analysis and reports can highlight areas of potential trouble By providing leading indicators iNet empowers you to address unsafe conditions or at risk behavior before problems happen REPORT TYPES Instrument Status Reports A weekly e mail report shows a summary that includes Days since last calibration Overdue calibrations Sensors with marginal span reserves Age of sensors Calibration gas expiration e Calibration bump test status Continuous monitoring of calibration gas cylinder pressure Warning Reports Show if any scheduled events were missed units not bump tested not calibrated not docked etc ee co 4 de cim Summary Reports Display gas alarm events by unit user site gas type date time duration concentration etc Alerts Sent immediately when there is an alarm incident failed calibration failed oxygen bump test or expired or empty calibration gas iNET PRICING A 48 month agreement locks in your pricing with no additional or hidden costs There s no guesswork involved Your gas detection budget will be simple and predictable Should your needs c
7. Electrochemical diffusion MEASURING RANGES Combustible Gases 0 to 100 LEL in 1 increments Hydrogen 0 to 999 ppm in 1 ppm increments Oxygen 0 to 30 by volume in 0 196 increments Ammonia 0 to 200 ppm in 1 ppm increments Carbon Monoxide 0 to 999 ppm in 1 ppm increments Hydrogen Sulfide 0 to 500 ppm in 1 ppm increments Sulfur Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments Hydrogen Cyanide 0 2 to 30 ppm in 0 1 ppm increments Hydrogen Chloride 0 2 to 30 ppm in 0 1 ppm increments Phosphine 0 to 1 ppm in 0 01 ppm increments Nitrogen Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments Nitric Oxide 0 to 999 ppm in 1 ppm increments Chlorine 0 2 to 99 9 ppm in 0 1 ppm increments Chlorine Dioxide 0 02 to 2 ppm in 0 01 ppm increments DISPLAY Dual channel split screen LED display 4 digit 7 segment ea INPUT VOLTAGE 12 28 VDC operating range 24 VDC typical INPUT CURRENT MAX SINGLE GAS UNLESS NOTED Toxic Gases or Oxygen 150 mA at 24 VDC Combustible Gases catalytic 175 mA at 24 VDC 0 6 A peak Combustible Gases infrared 150 mA at 24 VDC 0 6 peak Combined catalytic infrared 280 mA 24 VDC two gas Trans is also available as a complete stand alone fixed system Its audible and visual alarm are mounted directly to the iTrans and wired to the low and high alarm relays Different audible tones distinguish between low and high alarms while the ultra bright strobe and LED display
8. NGI eady SPECIFICATIONS CASE Type 304 Stainless Steel DIMENSIONS 12 1 cm x 8 1 cm x 4 3 cm 4 75 x 3 2 x 1 68 WEIGHT 524 5 g 18 5 2 SENSORS Combustible Gas Methane Catalytic Diffusion Oxygen and Toxic Gases Electrochemical MEASURING RANGES Combustible Gases 0 to 100 LEL in 1 or 50 ppm increments Methane 0 to 5 of volume in 0 1 increments Oxygen 0 to 30 of volume in 0 1 increments Carbon Monoxide Hydrogen Hydrogen Sulfide Nitric Oxide 0 to 999 ppm in 1 ppm increments Chlorine 0 2 to 50 ppm in 0 1 ppm increments Nitrogen Dioxide Sulfur Dioxide 0 2 to 99 9 in 0 1 ppm increments Hydrogen Cyanide Hydrogen Chloride 0 2 to 30 ppm in 0 1 ppm increments Ammonia 0 to 100 ppm in 1 ppm increments Chlorine Dioxide Phosphine 0 to 1 ppm in 0 01 ppm increments POWER SOURCE RUN TIME Rechargeable Lithium ion Li ion Battery Pack 24 hours typical 15 hours with iSP parasitic pump Replaceable AA Alkaline Battery Pack 12 hours typical TEMPERATURE RANGE 20 C to 50 C 4 F to 122 F typical HUMIDITY RANGE 15 to 95 RH non condensing APPROVALS 8 CE UL and CSA Class I Groups A B C D T4 Class I Zone 0 Ex ia d IIC T4 MSHA Intrinsically safe for Methane Air mixtures only ATEX EEx ia d IIC T4 Equipment Group and Category Il 2G M2 Australia Ex ia s Zone 01 IP65 Russia GOST R ned to grow with you as your monit
9. PEL Permissible Exposure Limit Level of gas in ppm a worker can be exposed to 8 hours a day 40 hours a week for the rest of their life with no long term health effects PID Photolonization Detector An instrument that utilizes ultra violet light energy to and detect the presence of an unknown gas or vapor ppm Part Per Million A common unit of measure ment for toxic gases This term literally means one part out of one million possible parts TLV STEL Short Term Exposure Limit The average amount of gas in ppm a worker can be exposed to in a 15 minute period with no long term health effects This may occur 4 times a shift with one hour between 15 minute exposures TLV TWA Time Weighted Average The average amount of gas in ppm a worker can be exposed to over a certain time period This time is defined as 8 hours to represent a normal work day TLV Threshold Limit Value A term used to signify limits in gas exposure TLV is used as a prefix for TWA and STEL UEL UFL Upper Explosive Limit Upper Flammable Limit The maximum concentration at which a gas will explode VAC Volts Alternating Current An electric current that reverses direction at regular intervals VDC Volts Direct Current An electric current of constant direction VOC Volatile Organic Compound Any compound containing carbon except methane that can be readily vaporized LOWER EXPLOSIVE LIMITS OF COMBUS
10. iTrans ACCESSORIES ITRANs REPLACEMENT SENSORS PART DESCRIPTION 77015741 c Calibration Cup for Infrared Sensor 77014579 By Pass Flow thru Kit not for infrared sensor 77015303 f Splash Guard Remote Cal Cup for Toxic and LEL 77018083 Replacement Filter for 77015303 77020063 b Splash Guard Remote Cal Cup for Infrared Sensor 77019644 Replacement Filter for 77020063 77024065 iTrans Calibration Wand 77023588 a iTrans Splash Guard 77023513 d iTrans Calibration Cup ITRANS MOUNTING KITS PART DESCRIPTION 78104312 STND Duct Mount Kit for iTrans Catalytic Toxic Oxygen 78104312 IR Duct Mount Kit for iTrans Infrared REMOTE SAMPLE PUMPS FOR iTrans AND AiRAwARE PART DESCRIPTION 78104130 Remote Sample Pump 24 VDC Operation 78104122 Remote Sample Pump 120 VAC Operation 77008118 Replacement Coalescing Filter Element 17045642 Stainless Steel Metal Insert for Compression Fitting for use with plastic tubing 77003580 Optional 3 way Valve for Calibration stainless steel 77004810 Optional Flash Arrestors 77014629 Replacement Diaphragm Kit POWER SUPPLIES PART DESCRIPTION 78101151 Model 6510 Power Supply Standard 110 VAC to 24 VDC 50 W output 78104809 80 Model 6520 Power Supply 24 VDC 80 W output 78104809 120 Model 6520 Power Supply 24 VDC 120 W output 78104809 240 Model 6520 Power Supply 24 VDC 240 W output 78101169 Model 6565 140 W Offline type UPS w Internal 24
11. 230 VAC 300 400 Series 18102558 Two Unit Smart Charger 120 VAC for 300 400 Series BATTERIES ADDITIONAL CHARGING ACCESSORIES PART DESCRIPTION 17059494 Spare Battery Pack Smart Charger Ni Cad 600 Series 17063884 Ni Cad Battery Replacement Module 600 Series 17059312 Spare Battery Pack Alkaline 600 Series 17041872 h Ni Cad Battery Pack 300 400 Series 17054735 h Ni Cad Battery Pack 300 400 Series Australian Approved 18102217 i Battery Charging Adapter 300 400 Series 17067174 Replaceable 9 volt Alkaline Battery Pack 300 400 Series 18102266 k Flying Lead Adapter for Dual Rate Chargers 17049889 I Replaceable Cell Lithium Battery Pack 300 400 Series 17047747 Lithium Battery 3V for 300 400 Series amp STX70 17031063 Ni Cad Battery Pack 200 Series Multi Gas 17025305 Ni Cad Battery Pack CD211 17024688 Ni Cad Battery Pack SP202 17022377 Spare Alkaline Battery Holder 200 Series Single Gas 17061755 Lithium Battery 9V T82 18103093 Charging Adapter 12 VDC Input Ni Cad ATX 17123019 Lithium Battery 3V GasBadge Pro 2 6 He cases permit hands free operation making portable gas monitoring instruments even more convenient to use In order to provide maximum versatility for all of our portable instruments Industrial Scientific offers a variety of optional carrying cases to fit any model For assistance in selecting the appropriate carrying case for your Industrial Scientific instrument
12. 6313545 FG 318 for 300 SC 6313647 SO sensor 0 30 ppm for CTX 300 6313546 FG SOL 218 for CTX 300 SC 6313648 SO sensor 0 100 ppm for CTX 300 6313547 FS 14 SP for CTX 300 SC 6313724 SO 0 10 ppm sensor block for IS OLCT 20 50 60 80 6793464 SP 13 FIS for CTX 300 SC 6313725 50 0 30 ppm sensor block for IS OLCT 20 50 60 80 S 6313772 Methylene Chloride or Methylene sensor block for 6313726 SO 0 100 ppm sensor block for IS OLCT 20 50 60 80 FLP OLCT 20 40 50 60 6113323 sensor 0 10 ppm 3 for CTX 6313773 R12 sensor block for FLP OLCT 20 40 50 60 6313558 sensor 0 10 ppm for 2042 6313774 R134A sensor block for FLP OLCT 20 40 50 60 6313649 Cl sensor 0 10 ppm for CTX 300 6313775 VOCs MOS sensor block for FLP OLCT 20 40 50 60 PURCHASE AND SERVICE OPTIONS DID ndustrial Scientific offers more than just the highest quality instruments and accessories In addition to our complete line of products we re also pleased to offer outstanding auxiliary services such as reliable service and repair comprehensive training and an ongoing commitment to provide you with the information you ll need to safely enter a potentially dangerous environment 4 2 OWNERSHIP SOLUTIONS or temporary needs to long term ownership Industrial Scientific offers a variety of purchase and rental plans to meet your specific needs time frame and budget Adding maintenance or repair options to your plan can help keep y
13. 8 Channel Analog Modules 40 channels 1 1 4 Relay Contact Module 4 Relays 6 6 8 Channel Analog Modules 48 channels 2 2 4 Relay Contact Modules 8 Relays LEGEM 3 3 4 Relay Contact Modules 12 Relays C DIGITAL DRY CONTACT INPUT OPTIONS 4 4 4 Relay Contact Modules 16 Relays 0 None G EVENT LOGGING OPTIONS 2 8 Channel Digital Input Module 0 None D MODBUS RTU INPUT CHANNELS SUPPORT OPTIONS 1 Datalogging 0 None H SCADA PLC DCS CONNECTION OPTIONS 8 Channels of RTU Supported 0 None 16 Channels of RTU Supported 1 ModBus Slave Support via Serial Phone or 24 Channels of RTU Supported Radio Modem Connection 32 Channels of RTU Supported 40 Channels of RTU Supported 48 Channels of RTU Supported 56 Channels of RTU Supported 64 Channels of RTU Supported 72 Channels of RTU Supported cO 01 2050 5 COMMON CONFIGURATIONS 4800 CONTROLLER ACCESSORIES PART DESCRIPTION PART DESCRIPTION 4800 12000210 4800 Controller 16 Analog Inputs 8 Relay Outputs 77026110 8 Channel Analog Input Card w Datalogging 77026128 4 Channel Relay Card 4800 12000200 4800 Controller 16 Analog Inputs 8 Relay Outputs 4800 12020210 4800 Controller 16 Analog Inputs 16 Digital ModBus Inputs 8 Relay Outputs w Datalogging 4800 14000200 4800 Controller 32 Analog Inputs 8 Relay Outputs 4800 10040211 4800 Controller 32 Digital ModBus Inputs 8 Relay Outputs Datalogging SCADA Con
14. Ethanolamine Ethoxyethyl acetate Ethyl acetate Ethyl acrylate Ethyl ketone Ethyl benzene Ethyl bromide Ethyl butyl ketone Ethyl ether Ethyl mercaptan Ethyl silicate Ethylamine Ethylene dibromide Ethylenediamine Ethyleneimine Furfural Furfuryl alcohol Gasoline Glycidol Heptane Hexane Hexanone Hexone Hexylacetate Hydroquinone Isoamyl acetate Isobutyl acetate Isobutyl alcohol Isophorone Isopropyl acetate Isopropyl alcohol Isopropyl ether Isopropylamine Isopropyl glycidyl ether JP 4 6 8 Ketene Mesityl oxide Methyl acetate Methyl acetylene Methyl acrylate Methyl amyl ketone Methyl bromide Methyl cellosolve acetate Methyl ethyl ketone Methyl hydrazine Methyl iodide Methyl mercaptan Methyl methacrylate Methyl styrene Methylamine Methylcyclohexane Methylcyclohexone Methylcyclohexanol Monomethylaniline Morpholine Naphthalene Naphthylamine Nitroaniline Nitrobenzene Nitromethane Nitrosodimethylamine Nitrotoluene Octane Pentaborane Pentane Pentanone Perchloroethylene Phenol Phenyl ether Phenylene diamine Phenylhydrazine Propyl acetate Propyl alcohol Propylene dichloride Propylene imine Propylene oxide Pyridine Quinone Stibine Stoddard solvent vapor Styrene Terphenyls Tetrachloroethylene Tetrachloronaphthelene Tetrahydrofuran Tetramethyl lead Toluene Toluidine Toner fluid vapor Trichloroethylene Triethylamine Turpentine vapor Vinyl chloride Vinyl toluene Whit
15. IDLH 40 000 0 ppm Breweries and Wineries Carbonated Beverage Bottling Plants Food Processing Plants Landfills STEL 30 000 0 ppm Carbon Monoxide CO Colorless odorless gas most abundant toxic gas OSHA PEL TWA 50 0 ppm NIOSH PEL TWA 35 0 ppm STEL 400 0 ppm IDLH 1 200 0 ppm LEL 12 5 of volume Fire Fighting Steel Mills Mining and Minerals Parking Garages Chlorine Cl Green yellow gas with a pungent irritating odor PEL TWA 0 5 ppm STEL 1 0 ppm IDLH 30 0 ppm Pulp and Paper Mills e Water Treatment Plants e Swimming Pools Chlorinization Plants Nuclear Reactors Chlorine Dioxide CIO Red yellow or orange green irritating odor PEL TWA 0 1 ppm STEL 0 3 ppm IDLH 5 0 ppm Pulp and Paper Mills Wastewater Treatment Plants Hydrogen H Colorless odorless gas PEL TWA No limit set by OSHA STEL N A IDLH No limit set by NIOSH LEL 496 by volume Chemical Manufacturing e HazMat Operations Power Generation Hydrogen Chloride HCI Colorless to slight yellow corrosive gas with a pungent irritating odor OSHA PEL TWA 5 0 ppm STEL N A LEL 12 5 of volume IDLH 50 0 ppm Vinyl Production e Cotton Production Petroleum and Gas Wells Steel Manufacturing Hydrogen Cyanide HCN Colorless toxic gas with a bitter almond like odor OSHA PEL TWA 10 0 ppm ACGIH PEL TWA 4 7 ppm STEL 4 7 ppm IDLH 50 0 ppm LEL 5 6 of volume Gold Plating In
16. If you have questions please contact Customer Service to discuss any design improvements and advantages AFTER SALE SUPPORT Warranty Industrial Scientific designs and manufactures the high est quality instruments for the preservation of life and property Our warranty statement GUARANTEED FOR LIFE is not just an empty promise Industrial Scientific warrants all parts including electronic components for the life of the instrument consumable items excluded Covers most portable instruments contact Industrial Scientific for additional warranty information Warranty Registration A postage free warranty registration card is delivered with each instrument This registration is a valuable step to ensure validation of warranty coverage Or if you prefer fax this information to 1 412 788 8353 or register your products online at www indsci com Repair Service If repair or maintenance on any Industrial Scientific product is required the Repair Service Center in Oakdale PA USA will accommodate your needs Authorized Service Centers are also located in Australia Canada China France Germany Netherlands Saudi Arabia Singapore and select regions of the United States Training Monthly Gas Detection Made Easy seminars are presented by Industrial Scientific s experienced Training Department in a hands on learning environment Customer site training is also available to meet your corporate needs for gas hazard education
17. MEASURING LINES CAPACITY 8 lines of 32 modules CABLE TYPE 2 shielded twisted pairs RS 485 cable MODULE POWER SUPPLY 12 to 30 VCC power supply delivered to modules DIGITAL MODULE NETWORK ModBus RS 485 1 32 addresses selected with mini switches DISPLAY Backlit LCD display screen 2 lines of 32 characters each 1 line of pictograms 3 operation status LEDs OK Fault Alarms ALARMS NUMBER OF ALARMS 6 per sensor Out of range Fault 3 LOCAL INTERNAL RELAYS R1 alarm fault R2 alarm R3 alarm MINIMUM CHARGE FOR RCT CONTACTS 2 250 VAC 30 VCC resistive charge DIGITAL OUTPUTS ModBus RS 485 protocol connection with a centralized supervision device RS 232 or USB USB protocol priority permanent connection to system configuration European countries as Germany the Netherlands and Belgium Economical The technology used in the Car Park System allows for the continuous monitoring and control of gas hazards within a facility The Car Park System significantly reduc es your operating costs by optimizing the efficiency of ventilation systems and servo controls Such efficiencies can produce energy savings of up to 4096 when used with certain equipment Adaptable Available wall and rack mounted versions the CPS central controller and various modules are user programmable for specific applications The system s networking technology also enables the Car Park System to adapt to any inst
18. O to 5 000 ppm Combustible gases catalytic 0 to 100 LEL MAXIMUM POWER CONSUMPTION 100 mA catalytic 25 mA chemical IS transmitter OUTPUT SIGNAL 4 20 mA Wheatstone bridge POWER SUPPLY AT THE DETECTOR 15 to 30 VDC catalytic 10 to 30 VDC chemical 10 to 26 VDC intrinsically safe transmitter Available Sensors ASsH CH Clo CIO CO H2S HCI HCN LEL NO O SiHa SO ntrinsically Safe IS and XP approved Corrosion resistant 4 20 mA output Pre calibrated sensor unit Small in size he OLC T 20 Series of gas detectors are designed for indoor or outdoor facility monitoring and other applications to accommodate your gas detection requirements at a reasonable price OLC 20 Detector The new generation of OLC 20 combustible sensors are unaffected by poisons The units provide extremely quick response times and complete reliability They can be fitted on a housing with a M25 or 3 4 NPT thread OLC 20D Detector Based on the OLC 20 sensor unit the OLC 20D detector is equipped with a 15 meter cable standard version and fitting gland for direct connection to a data logger A high temperature version allows operation up to 200 C New Generation New Advantages The stainless steel detector provides protection and resistance to corrosive agents Classified IP 66 they are resistant to dust and water ingress The precalibrated sensors of the
19. Quick and easy to install Power supply 230 VAC or 115 VAC and 24 VDC 48 VDC optional Clear messages Large LCD display unit Display in cyclic mode or direct mode by keypad Alarm status faults indicated by LEDs Three alarm levels separate alarm levels per channel pre programmed in the factory and adjustable by the user Built in relays to connect with fans and alarms Optimal equipment 2 separate relays per channel on 1st or 2nd threshold Common relay in case of failure Analog output by measuring channel Reliable control unit Protection against electromagnetic interference EMI Maintenance menu protected by access code Complete failure monitoring detectors control unit and line faults Microprocessor based design ORDERING INFORMATION PART DESCRIPTION W421420 MX42A 230 VAC and 24 VDC W420420 MX42A 230 VAC and 24 VDC European Version W421410 MX42A 110 VAC and 24 VDC B103829 Wall Mount Battery Backup System uninterrupted power supply 289 x 350 x 189 mm for MX32 and MX42 Charger 24 3 Batteries 7 Ah 1 2 Analog input channels On board relays LED and audible alarms Continuous auto test Flexible programming ALARMS 2 independent alarm thresholds per channel Individual programming increasing or decreasing levels Manual or automatic acknowledgement VISUAL ALARM 2 red LED gas alarms per channel 1 yellow LED fault per channel
20. SO Li ion 18107011 MX6 Battery Charger 12V MX6 0000R21 1 6 PID Ext Li ion Pump 18107136 MX6 Battery Charger 5 Unit MX6KIT K1230211 MX6 Confined Space Kit 4 gas w Pump 18107243 MX6 Truck Mount Charger 12V MX6KIT K123R211 6 Confined Space Kit 4 gas PID w Pump 18107250 6 Truck Mount Charger hard wired MX6KIT 0000R211 MX6 Kit PID Ext Li ion Pump 17131038 1 Rechargeable Li ion Battery Pack UL CSA ATEX MX6KITBOO00R211 6 Kit PID Ext Li ion Pump w Benzene Kit 17131038 2 Rechargeable Li ion Ext Battery Pack UL CSA ATEX 17131038 4 Rechargeable Li ion Battery Pack MSHA AUS 17131038 5 Rechargeable Li ion Ext Battery Pack MSHA AUS COMMON INDUSTRY CONFIGURATIONS 17131046 3 Alkaline Battery Pack UL CSA ATEX PART DESCRIPTION 17131046 6 Alkaline Battery Pack MSHA AUS MX6 KJ53R211 MX6 LEL CO H2S SO2 PID Ext Li ion Pump 18106856 0 Hard Leather Carrying Case Diffusion Petroleum Refining 18106856 1 Hard Leather Case Diffusion no display window MX6 K103Q21 1 MX6 LEL O Ext Li ion Pump Brewing Bottling Wineries 18106880 0 Hard Leather Carrying Case Aspirated MX6 KJ835101 MX6 LEL CO H S O SO CIO Li ion 18106880 1 Hard Leather Case Aspirated no display window Pulp Paper 18106831 Nylon Carrying Case MX6 supplied w MX6 diffusion MX6 K673R21 1 MX6 LEL Oz NH3 Ch PID Ext Li ion Pump HazMat 18106864 Nylon Carrying Case MX6 SP6 supplied w MX6 aspira
21. Sacramento CA San Francisco CA Los Angeles CA Denver CO Lakeland FL Palm Coast FL Atlanta GA Chicago IL Baton Rouge LA Baltimore MD Hollandale MN St Louis MO Voorhees NJ New York NY Farmington NM Portland OR Philadelphia PA Harrisburg PA Pittsburgh PA Fort Mill SC Corpus Christi TX Dallas TX Houston TX Midland TX Odessa TX Salt Lake City UT Richmond VA Waukesha VWI ASIA PACIFIC North Ryde NSW Australia Melbourne Australia Mount Lawley WA Australia Beijing China Chengdu China Urumqi China Singapore Kolkata India Mumbai India New Delhi India Jakarta Indonesia MIDDLE EAST Doha Qatar Dubai United Arab Emirates CANADA Calgary AB Edmonton AB Vancouver BC Aurora ON Point Edwards ON Toronto ON Niagara Falls ON Montreal QC MEXICO Guadalajara SOUTH AMERICA Paulo Brazil FRANCE Cesson S vign Lyon Montauban Moulins l s Metz BO Paris Vitrolles Marae Czech Republic United Kingdom INDUSTRIAL SCIENTIFIC 1001 Oakdale Road Oakdale PA 15071 1500 ADDRESS CORRECTION REQUESTED 1 412 788 4353 Fax 1 412 788 8353 www indsci com e mail info Qindsci com 02008 Industrial Scientific Corporation
22. 1 ppm in 0 01 ppm increments Nitrogen Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments operate independently or in a multi point configuration Nitric Oxide 0 to 999 ppm in 1 ppm increments transmitting a 4 20mA signal or ModBus RTU digital Chlorine 0 2 to 99 9 ppm in 0 1 ppm increments tout t devi PLC iTi Chlorine Dioxide 0 02 to 2 ppm in 0 01 ppm increments ou p Orally GONTOLUEVIGE or rans can 2150 DISPLAY work in a stand alone mode with optional on board Dual channel split screen LED display 4 digit 7 segment ea relays When gas concentrations exceed pre set limits INPUT VOLTAGE the unit can activate alarms horns and fans or shut 12 28 VDC operating range 24 VDC typical down systems without being wired back to a central INPUT CURRENT MAX SINGLE GAS UNLESS NOTED control panel Toxic Gases or Oxygen 150 mA at 24 VDC Combustible Gases catalytic 175 mA at 24 VDC 0 6 A peak Combustible Gases infrared 150 mA at 24 VDC 0 6 peak Combined catalytic infrared 280 mA at 24 VDC two gas APPROVALS NRTL c and CSA Class I Div 1 2 Groups C D AEx d IIB H2 ATEX Ex d IIB H2 T5 sensor specific IEC Ex d IIB H2 T5 sensor specific China GB 3836 1 Ex d IIC T4 LEL version GB15322 94 Fire protection i Irans Single or Dual Gas Monitor iTrans Monitors offers a wide variety of sensor configurations and relay options for maximum flexibility and affordabi
23. 1 ppm increments Hydrogen Sulfide H2S 0 500 ppm in 0 1 ppm increments Nitrogen Dioxide NO 0 150 ppm in 0 1 ppm increments Sulfur Dioxide 502 0 150 ppm in 0 1 ppm increments APPROVALS Gy MSHA IECEx N ANZEx UL Class I Division 1 Groups A B C D T4 Class Groups EG Carbonaceous 8 Grain Dust AEx d ia 4 IP66 IP67 ATEX Ex d ia I IIC T4 Equipment Groups and Category II 2G and M2 IP66 IP67 IECEx Ex d ia T4 IP66 IP67 INMETRO BR Ex d ia IIC 4 IP66 67 CSA Class I Division 1 Groups A B C D T4 C22 2 No 152 for LEL reading only Ex d ia 4 MSHA SPECIFICATIONS e Monitors O5 combustible gas and 2 toxic gases including CO H2S 50 or NO2 Ultra bright LED alarms Powerful 95 dB audible alarm e Small size weighs only only 180 grams 6 4 ounces Real time readout Large LCD display Lithium ion or alkaline battery operation he MX4 iQuad is an ideal personal monitor small rugged and simple to use It s tough with a high impact polycarbonate housing and protective rubber overmold The MX4 is also third party certified 66 and IP67 That means it is dust tight to withstand the dirtiest environments And it is water resistant passing both water jet and submersion tests To warn users in hazardous areas the unit uses a combi nation of three alarms ultra bright LEDs 95 dB audible alarm and a powerful vibrating alarm
24. 18 x 2 64 OPERATING TEMPERATURE 10 C to 45 C 14 F to 131 F SENSORS 1 flammable gas detector OLC 10 or 2 detectors OLC 10 TWIN for detection of methane butane propane in boiler rooms and LPG natural gas for vehicles 1 flammable gas transmitter OLCT 10 for detection of methane butane propane in boiler rooms and LPG natural gas for vehicles 1 to 5 similar detectors type OLCT 10 for detection of CO NO in parking garages DISPLAY Liquid Crystal Display 4 digits and user friendly symbols VISUAL INDICATIONS 4 LEDs 1 green Power On 1 orange Failure 2 red alarms Alarm 1 and Alarm 2 GAS AND UNIT Selectable from a preprogrammed list ALARMS amp RELAYS 2 programmable and independent levels decreasing or increasing alarms latching or unlatching modes local or remote acknowledgment 2 alarm relays normally energized selectable normally open or normally closed de energized on request at the factory 1 fault relay normally energized Relay ratings 2A at 250 Volts AC or 30 Volts DC APPROVALS ATEX 94 9 CE Directive Category 3G flammable gas detection metrology EN61779 1 and EN61779 4 Low Voltage Directive EN61010 EMC EN50270 ORDERING INFORMATION PART DESCRIPTION W151120 Channel Controller Type MX 15 230 VAC W150120 One Channel Controller Type MX 15 230 VAC European Version W151110 Channel Controller Type MX 15 110 VAC 67971
25. 50 60 80 6313734 Cl 0 10 ppm sensor block for IS OLCT 20 50 60 80 6313719 NO 0 100 ppm sensor block for 15 OLCT 20 50 60 80 6113362 sensor 0 30 ppm 0 100 ppm for Oo CT870 2042 200 6313720 NO 0 300 ppm sensor block for IS OLCT 20 50 60 80 6313561 ETO sensor 0 30 ppm for 2042 6313721 NO 0 1 000 ppm sensor block for IS OLCT 20 50 60 80 6313645 ETO sensor 0 30 ppm for CTX 300 6795578 sensor 0 10 or 0 30 ppm 3 for CTX 6313746 ETO 0 50 ppm sensor block for IS OLCT 20 6313556 sensor 0 30 ppm for 2042 6313682 HCN sensor 0 10 or 0 30 ppm 3 HN for CTX 6113332 sensor 0 30 ppm for OLCT 10 6313565 HCN sensor 0 30 ppm 2042 6313639 sensor 0 10 ppm for CTX 300 6313581 HCN sensor 0 100 ppm 2042 6313640 NO sensor 0 30 ppm for CTX 300 6313654 HCN sensor 0 10 ppm for CTX 300 6313722 NO 0 10 ppm sensor block for IS OLCT 20 50 60 80 6313655 sensor 0 30 ppm for CTX 300 6313723 0 30 ppm sensor block for IS OLCT 20 50 60 80 6313732 HCN 0 10 ppm sensor block for IS OLCT 20 50 60 80 6791911 H sensor 0 2 000 ppm 3 HYT for CTX 6313733 HCN 0 30 ppm sensor block for IS OLCT 20 50 60 80 6113335 H sensor 0 3 3 HYE for CTX TX 11 6313505 CIO chlorine dioxide sensor 3 0 3 ppm 6313559 H sensor 0 2 000 ppm for 2042 6313562 sensor 0 3 ppm for 2042 6313560 sensor 0 2 for 2042 6313678 CIO sensor 0 1 ppm for CTX 300 6313650 sensor 0 2 00
26. 9 ppm in 0 1 ppm increments Chlorine Dioxide 0 02 to 2 ppm in 0 01 ppm increments DISPLAY Dual channel split screen LED display 4 digit 7 segment ea INPUT VOLTAGE 12 28 VDC operating range 24 VDC typical INPUT CURRENT MAX SINGLE GAS UNLESS NOTED Toxic Gases or Oxygen 150 mA at 24 VDC Combustible Gases catalytic 175 mA at 24 VDC 0 6 A peak Combustible Gases infrared 150 mA at 24 VDC 0 6 peak Combined catalytic infrared 280 mA at 24 VDC two gas APPROVALS NRTL c and CSA Class I Div 1 2 Groups C D AEx IIB H2 ATEX Ex d IIB H2 T5 sensor specific IEC Ex d IIB H2 T5 sensor specific China GB 3836 1 Ex d IIC T4 LEL version GB15322 94 Fire protection nclosed within an explosion proof stainless steel housing the Stainless Steel iTrans is built to with stand corrosion in harsh environments such as offshore drilling platforms chemical plants or applications near a saltwater coastline iTrans fixed point gas monitors provide one or two points of detection from a single head for maximum flex ibility superior performance and lower installation costs The three or four wire system allows gas sensors to be mounted on board or remotely up to 200 meters away and can accommodate more than 200 transmitters in RS485 bus configuration Our industry proven smart sensor technology allows iTrans to monitor a wide range of gases for specific applications Safe
27. AUS MX6 iBrid iTX CHARGERS AND iTX VX500 BATTERIES PART DESCRIPTION 18104315 d Single Unit Compact Charger for iTX Universal 18105296 Single Unit Compact Charger for iTX 12 VDC 18104737 120 i TX Charger w Datalogging Kit 120 VAC 18104737 230 i TX Charger w Datalogging Kit 230 VAC 18104737 12 iTX Charger w Datalogging Kit 12 VDC 18104711 120 18104711 230 18104711 12 18105379 18106245 18106104 17089376 17088618 Charger Datalink 120 VAC Charger Datalink 230 Charger Datalink 12 VDC 6 Unit Charger w Flying Leads 8 Cradle for i TX universal input ITX Truck Mount Charger cigarette lighter adapter ITX Truck Mount Charger hard wired f Replaceable Cell Alkaline Battery Pack for iTX VX500 g Rechargeable Lithium lon Battery Pack for iTX V Xb00 PART DESCRIPTION 18106393 Single Unit Compact Charger Universal 18105502 Single Unit Automotive Charger 12 VDC 18105510 6 Unit Charger w Flying Leads amp Cradle for M40 18106229 1 M40 Trucke Mount Charger cigarette adapter 18106237 1 M40 Trucke Mount Charger hard wired 18106229 2 40 5 40 Truck Mount Charger cigarette adapter 18106237 2 M40 SP40 Truck Mount Charger hard wired 300 400 SERIES CHARGERS PART DESCRIPTION 18102145 Single Unit Compact Charger 12 VDC 300 400 Series 18102251 Two Unit Compact Charger 120 VAC 300 400 Series 18102231 Two Unit Compact Charger
28. BOARD ALARM 68100056 31010 NH Monitor w Power Supply Audio Alarm 0 No audio alarm 68100056 31100 NH Control w Audio Alarm 1 On board audio alarm wv vqv PQ TT TT 68100056 31300 NH Control Transmit w Audio Alarm OUTPUT OPTION d 9 68100056 71010 Monitor w Power Supply Audio Alarm 1 On board relays Control 68100056 71100 Control w Audio Alarm 2 4 20mA output Transmit 68100056 71300 Cl Control Transmit w Audio Alarm 3 4 20mA output and relays Control Transmit 68100056 A1010 O Monitor w Power Supply Audio Alarm D POWER OPTION 68100056 A1100 O Control w Audio Alarm 0 No adapter 1 AC Power Adapter Installed 68100056 A1300 O Control Transmit w Audio Alarm E VANITY PLATE FACEPLATE COVER OPTION 0 None 1 Vanity Plate Note AC Adapter is 110 VAC to 24 VDC N American plug AiRAwaRE REPLACEMENT SENSORS PART DESCRIPTION MONITOR 17071093 Ammonia Sensor 17051638 Carbon Monoxide Sensor Simple installation plugs into any standard 120 VDC wall outlet US version or uses 12 24 VDC operation 17077330 Chlorine Sensor Low high audio and visual alarms alert users to gas hazards 17077983 Chlorine Dioxide Sensor i i Single button calibration alarm muting and air zero functions 17886574 MEM AinAware CONTROL 17070186 Hydrogen Cyanide Sensor 17033960 Hydrogen Sulfide Sensor 12 24 VDC operation mapu i 17
29. Calibration Cup for O CO H S NO H 6331141 Calibration Cup for combustible gases 6121619 Mounting Kit for OLCT 20 6335976 Active Carbon Filter for OLCT 6335975 PTFE Water Barrier for OLC T 20 6343500 Cable Gland Kit for OLCT 50 60 M25 non armoured cable brass PART DESCRIPTION 6313829 Calibration Cup for OLCT IR 6313858 Sunshield for OLCT IR 6313862 Dust and Splash Guard 6313863 Calibration Cup amp Remote Sampling Cup for OLCT IR 6313946 Insect Guard for OLCT IR ACCESSORIES FOR OLCT 10 CTX CEX PART DESCRIPTION 6123717 Shock Guard Protector for OLC T 10 amp 300 Series 6313539 Junction Box for connection of 2 sensors to one channel 6321359 Splash Guard for CEX CTX 300 6322420 CEX CTX 300 Ceiling Mount 6323607 Gas Collector for 300 Series 6327905 Remote Sampling Cup for CEX CTX 300 amp OLC T 10 6327906 Remote Calibration Cup for CEX CTX 300 6331141 Calibration Cup for Combustible Gases 6335953 PTFE Water Barrier for CEX CTX 300 REPLACEMENT SENSORS FOR OLC OLCT CEX CTX PART DESCRIPTION 6513312 Catalytic C for CEX 800 6513368 Catalytic Sensor for CEX 810 CEX 870 6513388 High temperature Catalytic Sensor for CEX 810 CEX 870 HT 6792629 Catharometric Sensor for CEX 810 CEX 870 0 100 vol 6313662 Catalytic Sensor for CEX 300 6313757 Catalytic Sensor for OLC 20 6313995 Catalytic Sensor for OLC 20 0 100 LEL butadiene acetylene 6313759 Catharometric Sensor for OLC 20 0 100 vol CH 631
30. F Diffusion C e e N 0 0 NH Cl CIO PH HCN N gt N N ETO CO High CO H S LEL MOST COMMON INSTRUMENT CONFIGURATIONS PART DESCRIPTION 6514872 K12300 25 LEL CO H S 651487202300 BM25 LEL H S O 6514872 K10300 BM25 LEL CO 6514872 K00300 BM25 LEL 6514872 K03J50 BM25 LEL O2 5 SO 6514872 02350 BM25 LEL H S O2 SO 6514872 10300 BM25 LEL CO O2 6514872 67300 BM25 LEL NH Cb O2 6514872 K09J30 BM25 LEL CO H S 6514872 K12301 BM25 LEL CO H2S O2 Pump flashing beacon 6514872 K02301 BM25 LEL CO H2S Pump iJ Powerful audible alarm 103 dB 1m Run time greater than 100 hours 6514872 013000 BM25 O CO 6514872 010000 25 CO OPTIONAL ACCESSORIES C i 1 2 sec 1 beep 2 sec PART DESCRIPTION 6511157 BM25 Universal Charger w Power America WLOGUSB BM25 Datalink Adapter Kit Software w USB Adapter Cable 6321388 BM25 Tripod 6315862 BM25 Alarm Transfer Kit Cable length 25 m 6315863 BM25 Alarm Transfer Kit Cable length 50 m power supply 6315864 25 Alarm Transfer Kit Cable length 100 m i 6311085 BM25 Intrinsically Safe Trickle Charge Kit Cable length 25 m one IS power supply and wiring arrangements 6311089 BM25 Intr
31. GasBadge Pro is also compatible with the DS2 Docking Station to further simplify and automate cali bration function bump testing and data management Lifetime warranty SUPPLIED WITH MONITOR Battery attached suspender clip calibration adapter and tubing and instruction manual ORDERING INFORMATION Standard GasBadge Pro configurations are listed below To order the Australian approved version add an as a suffix to the part number PART DESCRIPTION 18100060 1 GasBadge Pro Carbon Monoxide 18100060 2 GasBadge Pro Hydrogen Sulfide 18100060 3 GasBadge Pro Oxygen 18100060 4 GasBadge Pro Nitrogen Dioxide 18100060 5 GasBadge Pro Sulfur Dioxide 18100060 6 GasBadge Pro Ammonia 18100060 7 GasBadge Pro Chlorine 18100060 8 GasBadge Pro Chlorine Dioxide 18100060 9 GasBadge Pro Phosphine 18100060 B GasBadge Pro Hydrogen Cyanide 18100060 C GasBadge Pro Hydrogen 18100060 G GasBadge Pro Carbon Monoxide Low Hydrogen Interference OPTIONAL ACCESSORIES PART DESCRIPTION 18106302 ABC GasBadge Pro 052 Docking Station 18106260 GasBadge Datalink Software included 18106500 GasBadge Constant Flow Hand Aspirated Pump 17121963 GasBadge Neck Lanyard w Safety Release 18106484 GasBadge Pro Nylon Carrying Case 18106492 GasBadge Pro 2 Unit Nylon Carrying Case 17124504 Replacement Water Dust Sensor Barriers 5 count DS2 Docking Station Ord
32. IEC 60079 1 Contain the Class 2 1 AEx d ia 5 AEX q Class 1 Zone 1 FM 3600 ISA 12 25 01 explosion and Explosion Groups EEx q Zone 1 EN 50 017 extinguish U S 505 l S Output Ex q Zone 1 IEC 60079 5 the flame Typical IEC Explosion Protected Gas Group AExnC Class Zone 2 FM 3600 ISA 12 12 02 sufre inter EM 50 021 s IEC 60079 15 Acetylene Group IIC Class l Group Hydrogen Group IIB Hz Class l Group B U S NEC9500 Intrinsic Safety 15 Class I Div 1 36107 Ethylene Group IIB Class l Group C Type of Protection AEx ia Class I Zone 0 FM 36101 Propane Group Class l Group D optional except for 1 5 Permitted AEx ib Class Zone 1 FM 36107 Methane Group 1 Mining Class 0 EN 50 020 39 Metal Dust None Class 1 E EEx ib Zone 1 EN 50 020 39 Coal Dust None Class II Group _ Grain Dust None Class II Group G 2 Fibers None Class 111 Not within scope of NEC Under jurisdiction of MSHA Permitted Zone Explosionproof with 1 5 Outputs Class Ex ia Zone 0 Division 1 Groups A B C D T5 Ex ib Zone 1 IEC 60079 11 GE Note 1 For associated intrinsically safe apparatus suitable for installation in Limit energy of a hazardous area the symbols for the type of protection ia or ib are enclosed sparks and surface except tar Divisio 5 and T6 optional within square brackets for example AEx dlia IIC
33. O2 deficiency and enrichment hazardous levels of methane gas CH4 as well as toxic levels of carbon monoxide CO and if applicable hydrogen sulfide H2S 40 ORDERING INFORMATION PART 18105940 01111 18105940 01110 18105940 01101 18105940 01100 18105940 00100 18105957 18105940 11111 18105940 11110 18105940 11101 18105940 11100 M40MKIT 11111 M40MKIT 11110 M40MKIT 11101 M40MKIT 11100 DESCRIPTION 40 O2 CHa CO H2S 40 Oz CHa H2S M40 m CHa CO 40 O2 CH 40 CH SP40 M Motorized Sampling Pump 40 5 40 Pump Combination O2 CO H2S 40 5 40 Pump Combination CH4 H2S 40 5 40 Pump Combination O2 CH4 CO 40 5 40 Pump Combination O2 CH M40 m Confined Space Kit w Pump O2 CH4 CO H2S 40 Confined Space Kit w Pump 5 M40 m Confined Space Kit w Pump CO 40 Confined Space Kit w Pump CH OPTIONAL ACCESSORIES PART DESCRIPTION 18105460 SP40 Motorized Sampling Pump 18106062 Constant Flow Hand Aspirated Pump 18105528 40 Datalink 18105478 Nylon Carrying Case 18105486 40 5 40 Combination Nylon Carrying Case 18106393 Single Unit Compact Charger Universal 18105502 Single Unit Automotive Charger 12 VDC 18105510 6 Unit Charger w Flying Leads 8 Cradle for M40 18106229 1 M40 Trucke Mount Charger 12V 181
34. On Board 0 No Sensor 7 XP 316 Stainless Steel Remote 7 XP 316 Stainless Steel Remote max distance 200m max distance 200m B GAS SENSOR 1 F GAS SENSOR 2 Required only for dual sensor version 1 Carbon Monoxide CO 1 Carbon Monoxide CO 2 Nitric Oxide NO 2 Nitric Oxide NO 3 Ammonia NH3 3 Ammonia 4 Hydrogen Sulfide H2S 4 Hydrogen Sulfide H2S 5 Sulfur Dioxide SO 5 Sulfur Dioxide SO 6 Nitrogen Dioxide NO 6 Nitrogen Dioxide NO 7 Chlorine Cl 7 Chlorine Cl 8 Chlorine Dioxide CIO gt 8 Chlorine Dioxide CIO 9 Hydrogen Cyanide HCN 9 Hydrogen Cyanide HCN A Oxygen 03 A Oxygen 03 B LEL Infrared factory methane calibration B LEL Infrared factory methane calibration C LEL Catalytic Plug In factory pentane calibration C LEL Catalytic Plug In factory pentane calibration D Carbon Monoxide Hydrogen Null CO H D Carbon Monoxide Hydrogen Null CO H F Hydrogen Chloride F Hydrogen Chloride G LEL Infrared Propane G LEL Infrared Propane Phosphine PH3 Phosphine PH3 L Hydrogen H L Hydrogen H C 4 20 mA OUTPUT SCALE FOR SENSOR 1 G 4 20 mA OUTPUT SCALE FOR SENSOR 2 0 0 999 Required only for dual sensor version 1 0 500 0 0 999 2 0 100 1 0 500 3 0 50 2 0 100 4 0 30 3 0 50 5 0 10 4 0 30 6 0 2 5 0 10 7 0 1 6 0 2 8 0 20 7 0 1 9 0 200 8 0 20 9 0 200 D OPTION
35. REFERENCE CHART MISCELLANEOUS ACCESSORIES FIXED MONITORING SYSTEMS INDUSTRIAL LIGHT INDUSTRIAL COMMERCIAL ITRANS SINGLE OR DUAL GAS Monitor ITRANS STAINLESS STEEL SINGLE GAS Monitor STAND ALONE ITRANS SINGLE GAS Monitor OLCT IR Gas Monitor 80 Fixen Gas Monitor OLCT 60 FixeD Gas Monitor OLCT 50 Gas Monitor OLCT 20 Gas Monitor OLCT 10 Fixen Gas Monitor OLC 10 FixeD Gas Monitor CEX 300 Gas Monitor CTX 300 Gas Monitor CPS Gas Monitor AiRAWARE LIGHT INDUSTRIAL SINGLE GAS Monitor MX 62 CONTROLLER 4800 CONTROLLER MX 52 CONTROLLER MX 48 CONTROLLER 1600 CONTROLLER 820 CONTROLLER MX 42 CONTROLLER MX 32 CONTROLLER MX 15 CONTROLLER WIRELESS AND REMOTE FIXED MONITORING SYSTEMS FixED PoiNT INSTRUMENT ACCESSORIES PURCHASE AND SERVICE OPTIONS PURCHASE AND SERVICE OPTIONS TURNKEY AND COMMISSIONING SERVICES TRAINING AND REFERENCE LIBRARY TRAINING TRAINING AND SUPPORT TOOLS REFERENCE LIBRARY ORDERING INFORMATION 3 1 387 3 4 3 6 3 8 3 9 3 10 3 11 3 12 3 13 3 13 3 13 3 13 3 14 3 16 3 18 3 20 3 22 3 22 3 23 3 23 3 24 3 25 3 25 3 26 3 27 4 1 O1 BH e o A PORTABLE NSTRUMENT SENSOR OPTIONS Multi Gas Monitors Single Gas Monitors MX6 iBrid MX4iQuad m BMS GasBadge Pro GasBa
36. TMX412 LTX310 MG140 140 Rattler User manuals for Industrial Scientific instruments are available online at www indsci com START UP TIP CARDS PART DESCRIPTION 17046848 Confined Space Booklet English 17052520 Confined Space Booklet Spanish 16000029 Gas Detection Made Easy Class Book TRAINING MAINTENANCE VIDEOS PART DESCRIPTION 16000055 DS2 Video CD English 17134545 MX6 Video DVD 16000039 VHS 16000042 PAL 16000047 ITX VHS Spanish 16000049 40 VHS English French Spanish 16000050 M40 Video CD English French Spanish 16000045 T40 VHS English Spanish 16000051 T40 Video CD English Spanish 16000037 CO and the First Responders VHS PART 17095795 17086745 CO897 16000036 DESCRIPTION 82 Carbon Monoxide Exposure CO Investigation Card TRAINING TUTORIALS PART 16000041 16000054 16000020 16000022 DESCRIPTION Interactive Training Tutorial CD ROM M40 Interactive Training Tutorial CD ROM ATX612 Interactive Training Tutorial CD ROM ATX620 Interactive Training Tutorial CD ROM 17056219 17063611 16000024 16000034 412 ver 2 0 Training Tutorial floppy TMX412 ver 2 0 Operation Only floppy LTX312 Interactive Training Tutorial CD ROM Carbon Monoxide Responder Training CD ROM Reference Library ach day Industrial Scientific Corporation receives hundreds of phone calls requesting information on ever
37. Technologies LLC R STAHL Inc Explosive Facts 6 1 Ordering Information CUSTOMER SERVICE ontact our Customer Service Department 24 hours a day by phone fax or e mail Phone lines are handled by friendly knowledgeable professionals 24 hours a day from 8 p m Eastern Time Sunday evening through 6 p m Friday evening Your call will be answered by a real person not an answering machine or an automated attendant with complicated menu selections Please contact Industrial Scientific at Phone 1 800 DETECTS North America 1 800 338 3287 North America 1 412 788 4353 Fax 1 412 788 8353 e mail info indsci com Also information on products and services can be accessed on the Industrial Scientific Web site http www indsci com Dealers and Distributors Industrial Scientific has a worldwide network of stocking distributors anxious to handle your needs Please contact Customer Service at 1 412 788 4353 e mail info indsci com or use the Distributor Locator found on www indsci com for the distributors serving your local area Prices and Terms Prices are subject to change without notice Terms of payment are Net 30 Days with established credit We also accept C O D Visa Mastercard and American Express orders Design Changes Due to continuing improvements in design some items may differ slightly from the description and photographs in the literature All specifications are subject to change without notice
38. Two year all inclusive warranty TRIAL jus Ie SCIENTIFIC SPECIFICATIONS CASE High visibility impact resistant composite RFI EMI amp IP65 approved DIMENSIONS 10 9 cm x 6 22 cm x 3 48 cm 4 30 x 2 45 x 1 37 WEIGHT 244 g 8 6 oz Weight with pump 326 g 11 6 oz SENSORS Combustible Gases Catalytic Diffusion Oxygen and Toxic Gases Electrochemical MEASURING RANGES Combustibles 0 to 100 LEL in 1 increments Methane 0 to 5 of volume in 0 1 increments M40 m only Oxygen 0 to 30 of volume in 0 1 increments Carbon Monoxide 0 to 999 ppm in 1 ppm increments Hydrogen Sulfide 0 to 500 ppm in 1 ppm increments POWER SOURCE RUN TIME Rechargeable Lithium ion Li ion Integral Battery 18 hours typical 12 hours with SP40 parasitic pump DATALOGGING Up to 75 hours of datalogging capability TEMPERATURE RANGE 20 C to 50 C 4 F to 122 F HUMIDITY RANGE 15 to 95 RH non condensing typical 0 to 99 RH non condensing intermittent use APPROVALS amp UL Class Groups A B C D 4 Class I Zone 0 AEx ia d IIC 4 CSA Class Groups A B C D 4 MSHA 40 only Intrinsically safe for Methane Air mixtures only ATEX EEx ia d IIC 4 Equipment Group and Category ll 2G Australia Ex ia s Zone 0 IIC TA Russia GOST R DP Scientific is pleased to offer the 40 versatile multi gas monitor capable of detecting CO H2S and combustible g
39. a stand alone Ethernet with 2 IDSs in a cluster sharing 2 cylinders of calibration gas ORDERING INFORMATION PART DESCRIPTION Monitor 18106724 ABC 052 Instrument Docking Station IDS for MX6 iBrid r 18105551 ABC 052 Instrument Docking Station IDS for iTX 18106302 ABC 052 Instrument Docking Station IDS for GasBadge Pro Instrument data is available at 18107698 ABC 052 Instrument Docking Station IDS for GasBadge Plus the local level A Wireless Option currently unavailable 0 none iu LARGE INSTALLATION SCENARIO CORPORATE SAFETY OFFICE CHICAGO IL USA iGas Reader number included 0 1 2 3 PLANT 2 RAYONG Ethernet Hu THAILAND C Power Cord Option 0 US 1 UK 2 EU 3 AUS 4 ITA 5 DEN 6 SWZ 18106543 5 MX6 iBrid DS2 Laptop Turnkey System IDS Cluster Ethernet Hub 18106543 1 ITX DS2 Laptop Turnkey System DU UDUCDOO p c 18106543 4 GasBadge Pro DS2 Laptop Turnkey System Server 17113978 DS2 PC with Windows Server OS Includes 1 052 Computer installed software Windows XP Professional DSS and DSSAC monitor keyboard mouse 5 port Ethernet hub and cables Includes keyboard and mouse Monitor not included DS2 not included PLANT 1 Ethernet Hub HOUSTON TX a IS USA IDS Cluster 1 Ethernet Hub Ethernet Hub OPTIONAL ACCESSORIES IDS Clust
40. alert workers that a gas hazard is present An optional 24 VDC power supply can be added to create a complete plug in functional system that is easy to install and operate 4 20 mA output and ModBus interface allow the unit to be connected directly to a PLC DCS or stand alone control system Industrial Scientific s smart sensor technology allows for single or dual sensor operation The sensors can be mounted directly onto the iTrans or placed remotely up to 200 meters away The unit can be upgraded in the field by adding a second sensor at a later date This capability makes the unit extremely flexible and cost effective Industries and Applications Steel Manufacturing LEL CO or CO H Null Drilling H2S and LEL Refining H2S LEL and SO Pulp and Paper Cl CIO SO and 5 Power Plants LEL O2 CO Water Waste Water Treatment Cl and H2S Food Processing NH3 and Tunneling Ventilation CO Stand Alone ITrans rixed Monitor iTrans Stand Alone System with on board audible and visual alarms offers a wide variety of sensor configurations and relay options for maximum flexibility and affordability Use the following guide to select the options that best fit your monitoring needs and applications Industrial Scientific recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements iTran
41. confined space awareness and instrument training Product training videos for users and supervisors are available in various formats for instrument operation calibration and maintenance Catalog Requests We would like to add you to the catalog mailing list Please notify Customer Service if the mailing label is incorrect or if you would like to be added to the list for future mailings Worldwide Operations www indsci com CORPORATE HEADQUARTERS INDUSTRIAL SCIENTIFIC AMERICAS Industrial Scientific Corporation 1001 Oakdale Road Oakdale PA 15071 1500 USA Phone 4 1 412 788 4353 Fax 1 412 788 8353 E mail info indsci com ASIA PACIFIC INDUSTRIAL SCIENTIFIC ASIA PACIFIC HEADQUARTERS 290 Guiqiao Rd Pudong Shanghai 201206 PR China Phone 86 21 5899 3279 Fax 86 21 5899 3280 E mail info ap indsci com EUROPE MIDDLE EAST AND AFRICA INDUSTRIAL SCIENTIFIC OLDHAM HEADQUARTERS 2 1 Est rue Orfila 417 62 027 Arras Cedex France Phone 33 3 21 60 80 80 Fax 33 3 21 60 80 00 E mail info eu indsci com a b EM T YE WINTER GmbH Gernotstr 19 44319 Dortmund Germany Phone 49 231 9241 0 Fax 49 231 9241 25 E mail info winter gmbh com 3 S og Sales and Service Manufacturing Operations Mobile Service Van Mobile Service Van Service Center DISTRICT OFFICES UNITED STATES
42. connection play shows Cal Plus status and set up menus Real time readings on for quick and easy data collection or instrument GasBadge Plus display during calibration configuration INTERNAL MEMORY Stores up to 200 bump test and calibration reports before overwrite Reports contain serial number time date sensor information pass fail span values and bump values for bump tests Memory will retain information when power is off OPTIONAL ACCESSORIES PART DESCRIPTION 17117722 Serial Data Dot Matrix Printer 120 230 VAC CAL PLUS ORDERING INFORMATION 17127044 Replacement Ribbon for Cal Plus Internal Printer Epson ERC 22 PART DESCRIPTION 17135518 Replacement Printer Paper Roll 57 mm x 48 mm x 25 18106344 0X Cal Plus Calibration Station 18102163 calibration gas and regulator not included Calibration Gas Carbon Monoxide 100 ppm 103L 18100859 Calibration Gas Hyd Sulfide 25 581 18106344 1X Cal Plus Calibration Station w on board dot matrix yerogen Sunde 29 Ppr printer calibration gas and regulator not included 18102219 Calibration Gas Nitrogen Dioxide 5 ppm 58L 3 Australian Plug Confined Space Kits Available in configurations to rior to working in any confined space environment meet a wide range P it s essential to have the right tools to ensure safe of needs Nun entry Industrial Scientific s Confined Space Kits are designed to make that as
43. hour battery back up A maximum number of 72 channels can be used However the maximum number of modules input and output cannot exceed six in any combination Industrial Scientific recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements 4800 Controller Base Part Number 4800 ABCDEFGH A Base Unit D ModBus RTU Input Channels Support Options Datalogging Options B Analog Input Options E Controller to Controller Support Options SCADA Connection Options C Digital Options F Relay Options Ordering example A 4800 Controller in a NEMA 4X wall mounted enclosure with 16 analog input channels 8 ModBus RTU input channels and 8 relay contacts would have a part number of 4800 12010200 4800 CONTROLLER PART NUMBER ORDERING MATRIX A BASE UNIT 1 NEMA 4X Wall Mount w Display 24 Hour Battery Back Up 2 Sub Panel Mount w Display 24 Hour Battery Back Up 3 Flush Mount w Display 24 Hour Battery Back Up 4 NEMA 4X Wall Mount Enclosure w Display 24 Hour Battery Back Up and Internal 24 VDC 100W Power Supply B ANALOG INPUT OPTIONS E CONTROLLER TO CONTROLLER SUPPORT OPTIONS 0 None 0 None 1 1 8 Channel Analog Module 1 Controller to Controller Communication Capable 2 2 8 Channel Analog Modules 16 channels 3 3 8 Channel Analog Modules 24 channels F RELAY OPTIONS 4 4 8 Channel Analog Modules 32 channels 0 None 5 5
44. interface 686 00 MEASURING RANGES 6313962 4 Relay Module 294 00 Carbon Monoxide 0 to 300 ppm in 1 ppm increments m Nitric Oxide 0 to 100 ppm in 1 ppm increments 6313963 8 Relay Module 329 00 Nitrogen Dioxide 0 to 30 ppm in 0 1 ppm increments r c Methane 0 to 10096 LEL in 196 increments 6313964 16 Logic Input Module 30100 Liquefied Petroleum Gas 0 100 LEL in 1 increments Hydrogen 0 to 100 LEL in 196 increments icd Analogie Output Module 59500 SENSOR REPLACEMENT 6311098 Emergency Power Supply 301 00 Sensor replacement switch on the interior of the CPS 10 case 6321400 Cable Gland Skirt for the CPS Wall Mounting Control Unit 21 00 5 RM4 OR RM8 RELAY MODULE 6114632 Integrated Printer AP1200 only for Rack Mounted Version 637 00 DIMENSIONS 125 mm x 165 mm x 60 mm 6090336 Paper Rolls for AP1200 b pc 1950 d 6114629 Desk Top Printer DPU 414 Ch t t NUMBER OF RELAYS esk Top Printer arger 595 00 4 relays CPS RM4 6090319 Paper Rolls for Desk Top Printer DPU 414 bpc 35 00 8 relays CPS 8 Contacts RCT type 6331163 Calibration Kit for CPS10 including a stainless steel bar 8400 MINIMUM CHARGE FOR and a magnetic calibration cap CONTACTS 6116026 Sub D Sub D Cable for PC 2 A 250 V over resistive 6116272 Prog USB Cable 21 00 ONSUMPTION E 6116273 Sub D Sub D Cable for Printer 3500 3 5 mA in normal operation Configuration of positive or ne
45. sensor options it has the flex ibility to protect many potentially hazardous environments Maintaining the unit is easy with pre calibrated sensors and an optional LCD display and toxic sensor versions only CERTIFICATION Safe area only 3 14 e Gas detection system for parking facilities and tunnels Up to 256 points per system Up to 1 000 times faster than a pump system Parking facility electricity savings of up to 40 Available Sensors CO LPG CPS CENTRAL DETECTION CONTROLLER SPECIFICATIONS WALL MOUNT DIMENSIONS 320 mm x 180 mm x 95 mm 12 6 x 7 09 x 3 74 DEGREE OF PROTECTION IP 54 CABLE GLAND Safe accurate and reliable The CPS Car Park System provides accurate and reliable monitoring for the highest level of protection in parking facilities and tunnels The system was designed 5 M20 cable glands 5 to 12 mm dia for power supply and local relays to comply with the high safety standards enforced in such 9 grommets Diameter 5 to 7 mm or PG 9 RACK MOUNT DIMENSIONS Length 19 Height 4 U 176 mm INGRESS PROTECTION IP31 OPERATING CONDITIONS TEMPERATURE RANGE 10 C to 40 C HUMIDITY RANGE 5 to 95 noncondensing MAIN POWER SUPPLY Voltage 85 to 264 VAC Current 1 5 A 115 VAC 0 8 A 230 VAC INTERNAL BACKUP BATTERY Optional 600 mA h capacity CONSUMPTION 140 mA 12 mA per measurement line 240 mA max
46. truism that great people working with great tools create better products and services That s our way of putting you first My personal pledge to you is that every Industrial Scientific person will serve you the way we like to be served with competence care enthusiasm and concern for your costs If we fail to meet your expectations in any Way please contact me at 1 412 490 1890 or e mail at kentm indsci com Thank you for reviewing our catalogue We look forward to serving you Sincerely yours fon Kent McElhattan Chairman WHY INDUSTRIAL SCIENTIFIC Quality Assurance e 509001 2000 Quality System Certified CSA Category Certified Third Party Certifications for intrinsic safety susceptibility to electromagnetic and radio frequency interference ingress protection and performance Global Presence Manufacturing facilities in USA France and China Offices in many countries throughout the world Distribution network established worldwide Established international accounts references available Guaranteed For Life Lifetime Warranty on most portable monitors Service Guarantee on all factory repairs One year warranty on all fixed point systems and accessories Ease of Use and Serviceability One button operation and calibration on most monitors Microprocessor controlled operation Easy sensor replacement and calibration in the field Local serv
47. typical TEMPERATURE RANGE 40 to 60 40 F to 140 F typical HUMIDITY RANGE 0 to 99 RH non condensing typical APPROVALS OM UL cUL Class I Groups A B C D 4 Class Groups E FG Class I Zone 0 AEx ia TA CSA Ex ia IIC 4 ATEX EEx ia 4 Equipment Group and Category Il 1G M2 IECEx Ex ia 4 Australia Ex ia I IIC T4 Russia GOST R D to Industrial Scientific s highest quality and reliability standards the full featured GasBadge Pro provides a lifetime of gas hazard protection with more features than any other single gas monitor available The instrument can be quickly adapted with interchangeable smart sensors to monitor unsafe levels of oxygen or any one of the following toxic gases carbon monoxide hydrogen sulfide nitrogen dioxide sulfur dioxide chlo rine chlorine dioxide phosphine ammonia hydrogen cyanide and hydrogen Each GasBadge Pro monitor comes standard with STEL and TWA readings datalogging of up to one year of survey data and an event logger that records the past 15 alarm events The monitor is customizable for any industry or application featuring user adjustable alarm and calibration gas setpoints as well as a user configurable alert or warning that signals when the instrument is due or overdue for calibration Housed in a rugged enclosure the monitor is immune to radio frequency water resistant and extremely durable A pr
48. 0 F to 140 F typical HUMIDITY RANGE 0 to 99 RH non condensing typical APPROVALS Wu MSHA UL cUL Class I Groups A B C D 4 Class Groups E EG Class I Zone 0 AEx ia TA CSA Ex ia IIC 4 MSHA Intrinsically safe for Methane Air mixtures only ATEX EEx ia T4 IP66 and IP67 Equipment Group and Category Il 1G M2 IECEx Ex ia T4 IP66 and IP67 Australia Ex ia T4 Russia GOST R Plus provides low cost personal protec tion from dangerous levels of carbon monoxide hydrogen sulfide oxygen nitrogen dioxide or sulfur dioxide with a number of high end features not found in other similarly priced instruments At 72 grams 2 5 ounces the two year maintenance free monitor s compact size and light weight allow it to be worn comfortably with a variety of clip attachments With the top mounted sensor the unit can also provide continuous and unobstructed protection even when placed in a shirt pocket The GasBadge Plus is housed in a rugged enclosure that is extremely durable and resistant to water and radio frequency interference A concussion proof overmold protects the unit from extreme abuse in a variety of harsh industrial environments The large LCD display includes a backlight for clear visibility in low light conditions and international graphic symbols for easy operation The GasBadge Plus be configured to show both gas type and direct gas read in
49. 0 mA OUTPUT SIGNAL OLCT 10 4 20 mA OUTPUT SIGNAL OLC 10 Wheatstone bridge POWER SUPPLY AT THE DETECTOR 15 to 30 VDC nominal 24 VDC ATEX EEx nA II C 4 Ingress Protection IP66 Equipment Group and Category 11 3 G EMC EN50270 Combustible gas monitor Durable housing Explosion proof sensor CEX 300 foe rie esigned for the industrial and commercial sector buildings schools boiler rooms etc the CEX 300 flammable gas detector has a durable housing and an explosion proof sensor The CEX 300 is designed to be connected to a con troller and can be placed in hazardous areas to guard against risk of a gas explosion The CEX 300 detector has an ingress protection rating of IP 66 dust proof and water resistant ATEX EEx ed IIC T6 25 to 60 C EEx ed IIC T5 25 to 70 C Ingress Protection IP66 Equipment Group and Category 11 2 EMC EN50270 SIL2 approved according to EN 50402 O5 CO or toxic gas monitor Designed for unclassified areas Optional backlit display e Durable in harsh environments Falla 1 pn m WIL 8 2 4262 m bd bd MA Farr CTX 300 hen hazardous levels of toxic gases carbon diox ide or oxygen threaten the safety of an unclassified area the CTX 300 can satisfy the most demanding safety requirements The CTX 300 transmits data in record time And with wide range of
50. 0 ppm for CTX 300 6313740 CIO 0 3 ppm sensor block for IS OLCT 20 50 60 80 6313651 sensor 0 2 for CTX 300 6313590 ozone sensor 3 electrode for CTX 6313706 H 0 2 000 ppm sensor block for FLP OLCT 20 50 60 80 6313572 Os sensor 0 1 ppm for 2042 6313727 H 0 2 000 ppm sensor block for IS OLCT 20 50 60 80 6313676 sensor 0 1 ppm for CTX 300 6113318 sensor 0 10 or 0 30 ppm 3 HL for CTX TX 11 6313735 0 1 ppm sensor block for IS OLCT 20 50 60 80 6313511 sensor 3 HCIS for CTX 50 100 200 6313518 phosphine sensor 0 1 ppm 3 for CTX 6313564 sensor 0 30 ppm for 2042 6313569 sensor 0 1 ppm for 2042 6313582 sensor 0 100 ppm for 2042 6313677 PHs sensor 0 1 ppm for CTX 300 6313652 sensor 0 30 ppm for CTX 300 6313737 PHs 0 1 ppm sensor block for IS OLCT 20 50 60 80 6313653 sensor 0 100 ppm for CTX 300 6313583 ASH sensor 0 500 ppb for 2042 6313730 HCI 0 30 ppm sensor block for IS OLCT 20 50 60 80 6313738 ASH 0 1 ppm sensor block for IS OLCT 20 50 60 80 6313731 HCI 0 100 ppm sensor block for IS OLCT 20 50 60 80 6313571 SIH sensor 0 50 ppm for 2042 6113321 SO sensor 0 10 or 0 30 ppm 3 ST for CTX 6313747 SIH sensor 0 50 ppm sensor block for IS OLCT 20 6313557 SO sensor 0 10 ppm for 2042 6313563 VCM sensor 0 100 ppm for 2042 6313577 SO sensor 0 100 ppm for 2042 6313544 FS 24 SP for CTX 300 SC 6313646 SO sensor 0 10 ppm for CTX 300
51. 06229 2 40 5 40 Truck Mount Charger 12V 18106237 1 M40 Trucke Mount Charger hard wired 18106237 2 40 5 40 Truck Mount Charger hard wired 17092941 Metal Belt Clip 17107582 Suspender Clip 18106070 CO Breath Sampler for M40 M Ca Calibration Station Stand alone operation he MeCal Calibration Station is capable of calibrat No PC is required ing function bump testing and charging the M40 Calibration instrument as well as the M40 SP40 instrument pump Function bump testing combination Available in single unit and six unit Battery recharging versions the M Cal can be ordered in any configura dei tion of bays for M40 or M40 SP40 combinations A serial connector provides simple connection to a serial data printer for hard copy printouts of each calibration and bump test SPECIFICATIONS MONITORS SUPPORTED M40 Software versions 4 0 and higher CONFIGURATIONS M40 only version M40 SP40 pump version Six unit versions all configurations DIMENSIONS Single Unit 10 24 cm x 15 24 cm x 17 78 cm 4 03 x 6 x 7 DIMENSIONS Six Unit 12 5 cm x 31 06 cm x 33 02 cm 4 92 x 12 23 x 13 GAS INLETS One fresh air one gas cylinder PUMP FLOW RATE six unit M Cal406 Calibration Station 0 25 LPM INPUT Universal AC power supply 110 240 VAC OPTIONAL ACCESSORIES IOS MM PART DESCRIPTION On board LEDs give status indication pass fail
52. 071242 Nitric Oxide Sensor Visual alarm audio optional Dual alarm relays can turn on fans and warning sirens or 17060591 Nitrogen Dioxide Sensor shut down d Pieces 17050129 Oxygen Sensor Single button calibration alarm muting and air zero functions 12 24 VDC operation 17077355 Phosphine Sensor 17060575 Sulfur Dioxide Sensor AirAwarRE TRANSMIT AirAware ACCESSORIES e Interfaces with any control device accepting 4 20 mA output Visual alarm to alert of potential gas hazards audio optional PART e Single button calibration alarm muting and air zero functions DESCRIPTION 67001198 Optional Vanity Cover AirAware C T 67000604 Calibration Adaptor Assembly includes cal adaptor tubing and reducer 12 24 VDC operation res TT RT TE 67000596 Calibration Adaptor for ARAwart adaptor onl e Interfaces with any control device accepting 4 20 mA output NE Dual alarm relays can turn on fans and warning sirens or 67000265 110 220 VAC 24 VDC Power Adapter shut down a process es 17099391 Nylon Strain Relief for 67000265 Power Supply Single button calibration alarm muting and air zero functions M 2 Controller 1 64 Analog input channels Redundant processor for continual measurements Serial connection for SCADA or DCS SIL2 and SIL3 Direct connections either on network or in loops umi Num 1 1 a p g ETTE TTT HE ERT I E EHHE ELL HH AE HE
53. 08 p Inline Dust Filter for iSP SP402 SP202 SP100 Pumps 17041740 q Dilution Tube for use w Sampling Pumps 17050688 r Quick Disconnect Fitting Female 17024597 s Replacement Filter for iSP 5 402 SP202 SP100 Pumps 17024191 s Replacement Filters Package of 5 17058157 t Internal Dust Filter WaterStop for MX6 ATX Series 17051611 u Quick Disconnect Fitting Male Threaded 17048273 v Luer Fitting Male 1 8 Barb 17050698 v Luer Fitting Male 3 16 Barb 17050689 w Quick Disconnect Fitting Male 1 8 Barb 17050775 x Quick Disconnect Fitting Male 3 16 Barb 17062498 Replacement Inlet Filter Assembly for ATX Series 17067034 ATX Right Angle Inlet Swivel Fitting 17051319 Dust Filter Water Stop for Hand Pumps 17007592 Tygon Tubing 1 8 ID per foot 17102005 Urethane Tubing Black 1 8 ID per foot 17093659 Urethane Tubing 3 16 ID per foot 18108043 6 Extendible Probe Tubing Kit for MX6 18102257 6 Extendible Probe Tubing Kit for iT X 300 400 Series 17051701 Replacement Probe Fitting for 18101396 17113168 SP40 Water Barrier 17119553 ISP Filter Guard 18102418 10 Sample Tube w Inline Filter 17136540 SP6 Filter Cap used w 18105155 X Batteries and Charging Accessories he MX6 Chargers and Charger Datalink accessories can charge the lithium ion battery packs either installed or separate from the instrument The Charger Datalink option includes a software and PC connection cable for instantly downloadi
54. 27 Wall Mount Battery Backup System 322 x 248 x 126 mm for MX15 Charger 24V 1 A Batteries 7 Ah 3 26 Uses advanced wireless technology Reduced costs faster installations e Flexible sensor placement nterference free reliability SL QE fm SPECIFICATIONS General specifications for WIT System transceiver and receiver repeater ENCLOSURE Fiberglass NEMA 4X or classified areas DIMENSIONS 26 7 cm x 21 6 cm x 15 9 cm 10 5 x 8 5 x 6 25 OPERATING ENVIRONMENT Temperature 40 C to 50 40 F to 122 F Humidity 5 to 95 RH non condensing OPERATING VOLTAGE 24 VDC or 100 240 VAC POWER CONSUMPTION 170 mA receive typical 350 mA receive max peak at 1 W transmission TRANSMIT POWER 1 W SPREADING CODE Frequency hopping ORDERING INFORMATION PART DESCRIPTION 78104718 RF900 Control Transceiver 78104726 RF900 Receiver Repeater U sing Industrial Scientific s proven reliable fixed point gas monitors the Wireless Information Transmission System adds an advanced wireless technology to eliminate extensive wiring reducing costs and adding almost unlimited flexibility The system uses a unique frequency hopping transmission signal to ensure that the monitors and controllers are in constant communication with each other This spread spectrum signal operating at a frequency of 902 928 MHz is not restricted by FCC operating license
55. 3988 Catharometric Sensor for OLC 20 0 100 vol H2 6313758 Poison Resistant Catalytic Sensor for OLC 20 6313714 Poison Resistant Catalytic Sensor for OLC 20 Chlorine Anti Poison For chlorinated products not effective with methane detection 6313741 Catalytic Sensor for OLC 50 6314005 Catalytic Sensor for OLC 50 0 100 LEL butadiene acetylene 6313761 Catharometric Sensor for OLC 50 0 100 vol CH REPLACEMENT SENSORS FOR OLC OLCT CEX CTX Fixed Systems Accessories PART DESCRIPTION PART DESCRIPTION 6313983 Catharometric sensor for OLC 50 0 100 vol 6313551 CO sensor 0 100 ppm for 2042 6313742 Poison resistant sensor for OLC 50 6313579 CO sensor 0 1 000 ppm for 2042 6313744 Poison resistant catalytic sensor for OLC 50 6313970 CO sensor 0 300 ppm for OLCT 10 Chlorine Anti Poison For chlorinated products not effective with methane detection 6313615 CO sensor 0 500 ppm CTX 300 for parking garages 6313689 High temperature catalytic sensor for 6313627 CO sensor 0 100 ppm for CTX 300 DE 6313628 CO sensor 0 300 ppm for CTX 300 6313685 Combustible gases 0 100 LEL sensor block for FLP OLCT 20 40 50 60 80 6313629 CO sensor 0 1 000 ppm for CTX 300 6313872 Combustible gases 0 100 LEL butadiene acetylene for 6313631 CO sensor 0 1 for CTX 300 6313632 CO sensor 0 10 for CTX 300 ee 6313690 CO 0 100 ppm sensor block for FLP OLCT 20 50 60 80 6313715 Poison resistant catalytic sensor for OLCT 20 40 50 60 80
56. 6313691 CO 0 300 ppm sensor block for FLP OLCT 20 50 60 80 Sue 6313692 CO 0 1 000 ppm sensor block for FLP OLCT 20 50 60 80 not effective with methane detection 6313687 Catharometric sensor for OLCT 20 40 50 60 80 ee 4 m 0 100 vol CH 6313986 Catharometric sensor for OLCT 20 40 50 60 80 0 100 vol H 6313369 sensor for MX 11 CTX 50 CTX 100 CTX 200 6313711 CO 0 100 ppm sensor block for IS OLCT 20 50 60 80 6313585 sensor 0 30 for 2042 6313712 CO 0 300 ppm sensor block for IS OLCT 20 50 60 80 6313754 sensor for CTX 300 6313713 CO 0 1 000 ppm sensor block for IS OLCT 20 50 60 80 6313660 special sensor for CTX 300 6113320 H2S sensor 0 30 or 0 100 or 0 1 000 ppm 3 H for CTX 6313710 0 30 vol sensor block for FLP OLCT 20 50 60 80 IM 6313748 0 30 vol sensor block for IS OLCT 20 50 60 80 dd UT 6313446 sensor 0 100 ppm 3 NH S 6313633 H2S sensor 0 30 ppm for CTX 300 6313524 NH snesor 0 1 000 ppm 3 NH S 6313634 H2S sensor 0 100 ppm for CTX 300 6313656 NH sensor 0 100 ppm for CTX 300 6313635 H2S sensor 0 1 000 ppm for CTX 300 6313657 NH sensor 0 1 000 ppm for CTX 300 6313695 H2S 0 30 ppm sensor block for FLP OLCT 20 50 60 80 6313893 sensor 0 5 000 ppm for CTX 300 a 6313696 HS 0 100 ppm sensor block for FLP OLCT 20 50 60 80 6313688 0 5 000 ppm Catalytic sensor block for OLCT 20 FLP 6313697 5 0 1 000 ppm sensor bl
57. 635 131 10 iTrans On Board NH3 w Relays Consult factory for availability additional gases ranges and certification information Subject to change without notice FI kl ec A E EL IEFrans Fixed Point Monitors Extremely corrosion resistant 316 stainless steel housing Low cost fixed point monitors with choice of sensor options Unique dual sensor platform on board amp remote placement 4 20 mA and ModBus interface for direct communication to any control device or PLC Highly visible split screen LED display SPECIFICATIONS ENCLOSURE 316 Stainless Steel explosion proof NEMA 7X IP66 rating SENSORS Combustible Gases Catalytic bead and or Non Dispersive Infrared NDIR Oxygen and Toxic Gases Electrochemical diffusion MEASURING RANGES Combustible Gases 0 to 100 LEL in 196 increments Hydrogen 0 to 999 ppm in 1 ppm increments Oxygen 0 to 30 by volume in 0 196 increments Ammonia 0 to 200 ppm in 1 ppm increments Carbon Monoxide 0 to 999 ppm in 1 ppm increments Hydrogen Sulfide 0 to 500 ppm in 1 ppm increments Sulfur Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments Hydrogen Cyanide 0 2 to 30 ppm in 0 1 ppm increments Hydrogen Chloride 0 2 to 30 ppm in 0 1 ppm increments Phosphine 0 to 1 ppm in 0 01 ppm increments Nitrogen Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments Nitric Oxide 0 to 999 ppm in 1 ppm increments Chlorine 0 2 to 99
58. 9 Type MX 52 fitted w power and CPU cards 16 channels 230 VAC W521010 Frame Rack 3 19 Type MX 52 fitted with power and CPU cards 16 channels 110 VAC W52102I Frame Rack 3 U 19 Type MX 52 equipped w power and CPU cards 16 channels version w galvanic isolation 230 VAC W521011 Frame Rack 3 U 19 Type MX 52 equipped w power and CPU cards 16 channels version w galvanic isolation 110 VAC 6451424 2 Channel Card 6111264 Uninterrupted power supply 425 x 315 x 120 mm Charger 24V 12A Batteries 24 Ah 4 and 8 Analog input channels On board relays 4 20 mA pass through Serial connection for SCADA or DCS SPECIFICATIONS CAPACITY 4 and 8 independent channel versions 4 channels standard DISPLAY Fluorescent 2 lines of 16 fixed or scrolling characters FAULT ALARMS Yellow LED on each channel Common fault relay GAS ALARMS 3 independent thresholds per channel Red LEDs Third threshold time delayed or mean value Manual or automatic reset 2 relay outputs per channel common relay on alarm 3 AUDIBLE ALARMS 80 dB at 30 cm RELAYS 2 gas alarm relays per channel 1 relay common for alarm 3 Programmable positive or negative safety on alarm relay Positive safety on failure Programmable N O or SIGNAL OUTPUT Analog 4 20 mA per channel Load resistance 600 max Serial RS 485 or 232 in ModBus J BUS Optional opto insulation format OPERATING TEMPERATURE 20 C to 55 4 F
59. AL ON BOARD RELAYS 0 No Relay Modules 1 With On Board Relays COMMON CONFIGURATIONS PART DESCRIPTION PART DESCRIPTION 7814635 6C21741 Stainless Steel iTrans On Board LEL amp 7814635 64110 Stainless Steel iTrans On Board H S w Relays Remote H2S With Relays 7814635 7 21741 Stainless Steel iTrans Remote LEL and 7814635 6C210 Stainless Steel iTrans On Board LEL w Relays Remote H2S With Relays 7814635 6G200 Stainless Steel iTrans On Board IR LEL No Relays 7814635 63910 Stainless Steel iTrans On Board NHs w Relays 7814635 61010 Stainless Steel iTrans On Board CO w Relays 7814635 3207C2 Stainless Steel iTrans Remote NH 8 Remote LEL Catalytic No Relays Consult factory for availability additional gases ranges and certification information Subject to change without notice 8 1 e Mounted audible and visual alarm Fixed Point Monitors tz Low cost fixed point monitors with choice of sensor options 4 20 mA and ModBus RTU interface for direct communication to any control device or PLC Highly visible split screen LED display gt p i a a i u Remote mount sensor configuration SPECIFICATIONS ENCLOSURE Cast aluminum poly bonded coating NEMA 4X IP66 rating ALARMS 105 dB audible alarm Ultra bright flashing beacon SENSORS Combustible Gases Catalytic bead and or Non Dispersive Infrared NDIR Oxygen and Toxic Gases
60. Available accessories for the MX4 include DS2 Docking Station MX Cal Calibration Station single unit char ger and single unit charger datalink MX4 Charger Datalink MX4 DS2 Docking shown with MX4 MOI SUPPLIED WITH MONITOR The MX4 comes standard with a charger belt clip and calibration cup with tubing 1 7 ORDERING INFORMATION BASE UNIT SENSORS XXXX BATTERY LANGUAGE waxexIx E pr pp som WSHAM Note There are many possible configurations If your specific needs aren t among the common configurations below please call 1 412 788 4353 or e mail us at info Qindsci com we will assist you with the best configuration for your gas detection needs MOST COMMON INSTRUMENT CONFIGURATIONS OPTIONAL ACCESSORIES PART DESCRIPTION PART DESCRIPTION 4 12311 MXA iQuad LEL CO 5 Li ion 18107151 ABC 052 Docking Station for MX4 4 12321 iQuad LEL CO H2S Alkaline Options 0 4 14311 MXA iQuad LEL CO Li ion B iGas Reader number included MX4 K 10311 MXA iQuad LEL CO Li ion 1 4 02311 MXA iQuad LEL H2S Li ion 2 MX4 K0031 1 MXA iQuad LEL Li ion 3 MX4 K0001 1 MX4 iQuad LEL Li ion C Power Cord 0 US 1 UK 2 EU 3 AUS 4 5 DEN 6 SWZ MXA L00011 MXA iQuad LEL methane Li ion 18108100 Single Unit Charger 18107037 Single Unit Charger Datalink REPLACEMENT SEN
61. CIPLES Catalytic Electrochemical for a variety of applications The OLCT 60 Series includes several versions MEASURING RANGES XP or IS sensor toxic or oxygen versions Oxygen 0 to 30 by volume Remote or on board sensor OLCT 60AD Carbon Monoxide 0 to 100 0 to 300 and 1 000 ppm Hydrogen Sulfide 0 to 30 0 to 100 and 0 to 1 000 ppm version allows the sensor to be installed remotely Nitric Oxide 0 to 100 0 to 300 and 0 to 1 000 ppm up to 15 meters standard allowing detection in Nitrogen Dioxide 0 to 10 and 0 to 30 ppm Sulfur Dioxide 0 to 10 0 to 30 and 0 to 100 ppm inaccessible locations or in Zone 0 in the case of Chlorine 0 to 10 ppm the intrinsically safe IS version Hydrogen 0 to 2 000 ppm Hydrogen Chloride 0 to 30 and 0 to 100 ppm OLCT 60 detector units are made of 316L stainless Mee Fto land steel and are rugged and resistant to corrosion Pre Ammonia 0 to 100 and 0 to 1 000 ppm i Ozone 0 to 1 ppm calibrated sensors can be disconnected by turning the Phosphine 0 to 1 ppm head of the unit These smart sensors can be Chlorine Dioxide 0 to 3 ppm Silane 0 to 50 ppm Arsine 0 to 1 ppm Methane catharometer 0 to 10096 by volume Hydrogen catharometer O to 10096 by volume Ammonia catalytic O to 5 000 ppm Combustible gases catalytic 0 to 100 LEL calibrated outside hazardous areas DISPLAY mE AP
62. E Optional 24 VDC 45 W and 100 W power supplies available DISPLAY LCD backlit auto shutoff OUTPUTS 1 relay SPDT RS 232 Serial Port CONTACT RATINGS 0 5 A at 120 VAC OUTPUT CONNECTORS RS 232 9 Pin D Sub miniature male Relay Quick disconnect screw terminal Input voltage 12 VDC ORDERING INFORMATION PART DESCRIPTION 1600 12211 NEMA 4X Wall Mount Enclosure w 12 V 45 W power supply 1600 22211 Flush Sub Panel Mount w 12 V 6 W power supply 1600 32211 NEMA 4X Wall Mount Enclosure w 12 V 100 W power supply Can power 6 iTrans units or 16 Digital Transmitters External power supply must be supplied to power iTrans and Digital Transmitters Can power 16 iTrans units single sensor versions or 16 Digital Transmitters 3 23 Low cost controller for installations up to 2 channels Flexible ModBus RTU interface 4 20 mA outputs R70 Controller 209 820 Controller flexible solution for fixed point gas monitoring installations the 820 Controller is ideal for a wide range of applications from simple local monitoring to more elaborate network setups SPECIFICATIONS ENCLOSURE ABS Composite rack mount DIMENSIONS 10 8 cm x 13 8 cm x 12 8 cm 4 25 x 5 4 x 5 0 WEIGHT 560 kg 20 oz INPUTS Two 4 20 mA analog inputs ANALOG OUTPUTS 5 relays 2 low alarm 2 high alarm 1 fault alarm relays N O fault relays N C Two 4 20 mA outputs DIGITAL OUTPU
63. EL he MX 62 provides redundant system to ensure EE an accurate analysis from the sensors The MX 62 monitor has incorporated these new requirements and other future needs Through its modularity flexibility and reduced operating costs the MX 62 is an attractive solution for all gas and flame detection needs MX 62 system meets the requirements of 100 A and offers the high level of security required by SK2 and SIL2 rated systems A secure installation for optimized costs An entirely secure installation The structure of the MX 62 system has been devel oped to provide dual measurement Reliable data is passed quickly from the detectors to the relays A structured programming he ConfigPro Exe software configures the MX 62 via a PC Access to the different functions is protected by several passwords Space saving and easy access An optimized cost he innovative design meets the new requirements in terms of security and safety modularity allows a personalized operation and reduces wiring costs The flexibility helps integration of your system reliability ensures minimum maintenance Programmable outputs reduce relay requirements SPECIFICATIONS CAPACITY 64 secure channels per system 128 channels per console INPUTS 4 20 mA Digital Electric opening box and console OUTPUTS DISPLAY 4 20 mA Digital Relays 128 max High definition graphic al
64. GAS DETECTING ANDMON TORING SOLUTIONS FOR LIFE 4 INDUSTRIAL SCIENTIFIC na CORPORATION VoL 7 NO 1 hs PRESERVING HUMAN LIFE IS OUR LIFE S WORK INDUSTRIAL OUR MISSION SCIENTIFIC Preserving human life on above and below the earth Delivering highest quality best customer service every transaction every time To Our Valued Customers Industrial Scientific is 100 committed to fulfilling the promises we make to you in our mission statement Redefined in 2008 for undisputed clarity our mission promises highest quality and best customer service every transaction every time The products we manufacture and the services we provide are life critical We have created an environment within Industrial Scientific that is dominated by the responsibilities we have to the lives of the men and women who use our products We never forget that a human life depends on every product and every action of our people Industrial Scientific is fortunate to have so many humble hungry smart people around the world We are united by our commitment to do whatever it takes to preserve human life I have confidence you will be delighted with our people as they serve you Serving others is our greatest joy Our management philosophy supports our people as they serve you We believe that good financial performance is the result of doing the right things for our employees first customers second and shareholders third I think it s a
65. It even supports on board graphing for easily interpreting real time readings and recorded data in the field The MX6 can be customized to specific applications with the choice of 24 sensor options multiple languages and diffusion mode or internal sampling pump operation Built and tested to withstand the harshest work envi ronments the MX6 carries a lifetime warranty Maintaining your fleet can be automated with our DS2 Docking Station and managing your fleet can be outsourced with our iNet Instrument Network APPROVALS Gh 64 UL Class I Groups A B C D T4 Class Groups EG AEx ia d IIC 4 CSA Class Groups T4 Ex d ia IIC T4 MSHA CFR30 Part 18 and 22 Intrinsically safe for methane air mixtures EEx ia d I IIC IP65 64 pump version Equipment Group and Category 11 2G I M1 I M2 w IR sensor SUPPLIED WITH MONITOR Universal charger nylon carrying case belt clip calibration cup wrist strap maintenance tool manual quick start guide calibration tubing dust filter water stop pump versions calibration fitting pump versions sample tubing pump versions MX6 IBrid mutti cas Monitor Calibrating H25 SOZ Pass 34 Pending THE MX6 iBRID COLOR DISPLAY Enhanced Visibility Expanded Functionality 10 CO LEL Pending Pending U T TES D 15 30 45 60 Previous Next An intuitive menu provides easy View datalog
66. O to 5 000 ppm Combustible gases catalytic 0 to 100 LEL VOCs general 0 to 500 ppm Carbon Monoxide Hydrogen null 0 to 1 000 ppm DISPLAY 4 digit LCD display for measurement and one alphanumeric line for texts Pictograms backlighting 4 indicator lamps 1 green Operation OK 1 yellow Fault 2 red Alarm 1 and Alarm 2 in compliance with the strictest specifica tions the OLCT 80 is a major breakthrough in combining technical performance and cost optimization With a wide range of sensor options the OLCT 80 can meet a variety of needs at the largest industrial facilities ACCESSORIES Infrared remote control ool kit Bypass adapter Cover key Calibration cup Splash guard Remote gas introduction device Gas collector ATEX EEx d IIC T5 T100 C or T6 T85 C EEx d ia IIC T4 T135 C Equipment Group and Category 11 2 GD EMC EN50270 3 10 ntrinsically Safe IS and XP approved Corrosion resistant 4 20 mA output Back lit display Pre calibrated sensor Non intrusive local calibration OLCI 60 Available Sensors AsH CH Clo CIO CO H2S HCI HCN LEL NO PH SIH SO SPECIFICATIONS HOUSING Stainless steel type 316 L pd the OLCT 60 a new generation of high ENCLOSURE quality gas detectors which covers all industrial needs AS7 606 alloy epoxy polyester paint DETECTION PRIN
67. OLCT 20 and OLCT 20D can be discon nected by turning the head of the unit These smart sensors can be calibrated on a work bench outside hazardous areas Flameproof detector and transmitter ATEX EEx d T6 Ingress Protection IP66 Equipment Group and Category 11 2 GD EMC EN50270 Intrinsically safe transmitter ATEX EEx ia IIC T4 Ingress Protection IP66 Equipment Group and Category 11 1 GD EMC EN50270 Toxic or combustible gas monitor OLCT 10 e Combustible gas monitor OLC 10 Designed for boiler rooms and car parks ATEX Approved for use in hazardous areas P66 Di for use in boiler rooms and parking garages the OLCT 10 and OLC 10 monitors give you the most cost effective solution for the continuous monitoring of toxic OLCT 10 or flammable gases OLCT 10 OLC 10 and vapors in ambient air Easy to install and operate these detectors combined with the MX 15 control unit meet demanding user requirements SPECIFICATIONS HOUSING ABS IP RATING Third party certified IP66 DETECTION PRINCIPLES Catalytic Electrochemical MEASURING RANGES OLCT 10 Carbon Monoxide 0 to 300 ppm Nitric Oxide 0 to 100 ppm Nitrogen Dioxide 0 to 30 ppm Combustible gases catalytic 0 100 LEL MEASURING RANGE OLC 10 Combustible gases catalytic 0 100 LEL TEMPERATURE RANGE 10 C to 45 C 14 F to 113 F HUMIDITY RANGE 15 RH to 90 RH MAXIMUM POWER CONSUMPTION 3
68. PROVALS Backlit LCD display 4 digits pictograms 2 LEDs Backlight LCD display 4 digits pictograms 2 LEDs ATEX IEEx d IIC 6 MAXIMUM POWER CONSUMPTION EEX d ia IIC T4 w IS sensor 100 mA catalytic 40 mA electrochemical Equipment Group and Category 11 2 GD OUTPUT SIGNAL 4 20 mA OLC 50 Fixed Monitor OLC T HOUSING Stainless steel type 316 L ENCLOSURE AS7 606 alloy epoxy polyester paint DETECTION PRINCIPLES Catalytic Electrochemical MEASURING RANGES Oxygen 0 to 3096 by volume Carbon Monoxide 0 to 100 0 to 300 and 1 000 ppm Hydrogen Sulfide 0 to 30 0 to 100 and 0 to 1 000 ppm Nitric Oxide 0 to 100 0 to 300 0 to 1 000 ppm Nitrogen Dioxide 0 to 10 and 0 to 30 ppm Sulfur Dioxide 0 to 10 0 to 30 and 0 to 100 ppm Chlorine 0 to 10 ppm Hydrogen 0 to 2 000 ppm Hydrogen Chloride 0 to 30 and 0 to 100 ppm Hydrogen Cyanide 0 to 10 and 0 to 30 ppm Ammonia 0 to 100 and 0 to 1 000 ppm Ozone 0 to 1 ppm Phosphine 0 to 1 ppm Chlorine Dioxide 0 to 2 ppm Silane 0 to 50 ppm Arsine 0 to 1 ppm Methane catharometer 0 to 100 by volume Hydrogen catharometer O to 10096 by volume Ammonia catalytic O to 5 000 ppm Combustible gases catalytic 0 to 100 LEL MAXIMUM POWER CONSUMPTION 100 mA catalytic 25 mA electrochemical IS transmitter 340 mA Wheatstone bridge OUTPUT SIGNAL 4 20 mA Wheatstone
69. SORS 18108282 6 Unit Charger American plug only PART DESCRIPTION 18107680 0X Calibration Station 17134461 Oxygen 02 X Power Cord 0 US 1 UK 2 EU 3 AUS 17134479 Hydrogen Sulfide H2S Te NOE 17134487 Carbon Monoxide CO 18107763 Serial data dot matrix printer for MX Cal 17134495 Combustible Gas LEL CHz 18107904 Hand Pump manual bulb 17134503 Nitrogen Dioxide NO 18107888 Hard sided Leather Carrying Case 17143595 Sulfur Dioxide SO 18107813 Soft sided Carrying Case 17134453 1 Replacement Battery Pack Li ion UL CSA ATEX lt 17134446 1 Replacement Battery Kit Alkaline UL CSA ATEX ho includes pack cover and three 3 AAA alkaline batteries Wer x n LL 17134453 2 Replacement Battery Pack Li ion MSHA AUS f E 17134446 2 Replacement Battery Kit Alkaline MSHA AUS MX4 Sensors MX4 Alkaline includes pack cover and three 3 AAA alkaline batteries MX4 Li ion MX4 Battery S Battery Serial Data Dot Matrix Printer MX Cal Calibration Station I TX multi Gas Monitor Monitors from one to six gases Wide range of field replaceable sensors User and site ID data entry Datalogging capability standard Dot matrix display with backlighting 50 ppm resolution for hydrocarbons LEL CH over range protection 24 hour runtime with Lithium ion batteries DOCKING STATION
70. SP SP402 SP202 SP100 Pumps t Dust Filter Water Stop 1 2 micron for ATX Series u Quick Disconnect Fitting Male Threaded v Luer Fitting Male 1 8 or 3 16 Barb w Quick Disconnect Fitting Male 1 8 Barb x Quick Disconnect Fitting Male 3 16 Barb Remote Sampling Equipment 5 6 MOTORIZED SAMPLING PUMP for use with all MX6 iBrid Instruments PART DESCRIPTION 18106765 e SP6 Motorized Sampling Pump Module ISP MOTORIZED SAMPLING PUMP for use with all iTX Instruments PART DESCRIPTION 18104646 d iSP Motorized Sampling Pump SP402 MOTORIZED SAMPLING PUMPS for use with MG140 and all 300 and 400 Series Instruments Motorized pumps operate on Ni Cad Lithium or Alkaline batteries add the suffix L for the Lithium version or for the Alkaline version PART DESCRIPTION 18102156 a SP402 Sampling Pump for 300 400 Series 18102169 a SP402 Sampling Pump for 300 400 Series CSA SP40 MOTORIZED SAMPLING PUMP for use with all M40 and M40 M Instruments PART DESCRIPTION 18105460 c SP40 Sampling Pump for M40 18105957 c SP40 Sampling Pump for M40 M CONSTANT FLOW HAND PUMPS Economical operation with a supplied tubing length of 10 PART DESCRIPTION 18107078 b Constant Flow Hand Aspirated Pump for MX6 18105189 b Constant Flow Hand Aspirated Pump for i TX 18106062 b Constant Flow Hand Aspirated Pump for M40 18106500 b Constant Flow Han
71. T4 temperature Permitted Division Temperature Class Note 2 For associated intrinsically safe apparatus not suitable for installation Temperature Class in a hazardous area both the symbol Ex AEx EEx and the symbol for the Maximum U S NEC9505 U S NEC amp 500 type of protection ia or ib are enclosed within the same square brackets for Surface IEC EU Directive 94 9 EC ATEX from July 1 2003 example AEx ia IIC In this case a temperature class is not included Temperature EU Permitted Gas Group Type of Protection Temperature AEXnA Class I Zone 2 FM 3600 ISA 12 12 02 European Class Zone 2 EN50 021 Standard Group Zone 2 IEC 60079 15 Zone2 EN 50 021 Zone2 IEC 60079 15 Pressurized Class I Div 1 FM 3620 Class I Div 1 FM 3620 Class I Div 2 FM 3620 Explosion Gas Group Protected Zone 1 EN 50 016 Zone2 EN 50 021 Zone 1 IEC 60079 2 CE Conformity Marking Type of Explosive Atmosphere Zone 1 IEC 60079 2 G for gas vapor and mist Explosion for dust Zone2 IEC 60079 2 Protection Zone2 IEC 60079 15 Marking i T Restricted Breathing Class I Zone 2 FM 3600 ISA 12 12 02 Keep flammable Zone 2 EN 50 021 gas aui Ingress Protection IP Codes CE 0000 amp Zone 2 IEC 60079 15 First Number Second Number IM AEX m Class I Zone 1 FM 3600 ISA 12 23 01 Protection Against Solid Bodies Protection Against Liquid T EEx m Zone 1 EN 50 028 No protection No protection 1 SS i 2
72. TIBLE GASES The following are the lower explosive limits of selected gases which should be useful Acetone 2 5 of volume Acetylene 2 5 of volume Benzene 1 2 of volume Butane 1 996 of volume 1 4 of volume 1 996 of volume Butyl Alcohol Butanol Diethyl Ether Ethane 3 096 of volume Ethyl Alcohol Ethanol 3 3 of volume Ethylene 2 7 of volume Ethylene Oxide 2 7 of volume Hexane 1 196 of volume Hydrogen 4 0 of volume Isopropyl Alcohol Isopropanol 2 0 of volume Methane 5 0 of volume Methyl Alcohol Methanol Methyl Ethyl Ketone 6 0 of volume 1 496 of volume n Pentane 1 4 of volume Propane 2 196 of volume Propylene 2 096 of volume Styrene 0 9 of volume Toluene 1 1 of volume Xylene 1 1 of volume Reference Library he carboxyhemoglobin level is a measure of the amount of Carbon Monoxide which has been PETN absorbed into the blood stream The chart converts the E amount of Carbon Monoxide measured in the exhaled breath to the percentage carboxyhemoglobin level in S the blood The UL 2034 level 10 carboxyhemoglobin UL 2034 LEVEL YY depicted on the chart shows the average carboxyhemo globin concentration after a fifteen minute exposure to 400 ppm Carbon Monoxide At this exposure level the average person will begin to experience the symptoms of Carbon Monoxide poisoning WEIGHT OF VARIOUS GASES COMPARED TO AIR The following gases are lighter than air The following gase
73. TIME 12 24 VDC 110 220 AC adapter optional with N American plug TEMPERATURE RANGE 20 C to 50 C 4 F to 122 F typical consult factory for gas specific temperature ranges HUMIDITY RANGE Oxygen 0 99 Ammonia Carbon Monoxide Hydrogen Sulfide Nitrogen Dioxide Sulfur Dioxide 15 9096 APPROVALS BP CSA C 22 2 No 205 M 1983 Non hazardous locations ndustry proven performance combined with a new low profile design make the Industrial Scientific AirAware a logical choice for those critical areas that require continuous monitoring but not the environmental protection of an explosion proof enclosure Providing discrete monitoring and enhanced aesthetics for more commercial or institutional settings the AirAware Series is the ideal solution for reliable low cost fixed point monitoring The AirAware can be configured to operate as a monitor with local LED display a controller with on board relay switching capability a transmitter with 4 20mA outputs or as a controller transmitter with on board relays Each configuration is designed to meet your specific indoor monitoring needs Every AirAware is equipped with electrochemical sensing technology dual alarm LEDs a digital display providing real time read ings ModBus RTU outputs push button operation and a NEMA 4 type enclosure When alarm conditions are met low high alarm visual indicators alert users to gas hazards Standard operating po
74. TS RS 485 ModBus RTU Slave interface DISPLAY 2 channels 4 digit 7 segment LED ea channel PROGRAMMING INTERFACE Local keypad 4 keys plus clear ALARM NOTIFICATION 2 channel real time display notification LED alarm notification audible alarm notification TEMPERATURE RANGE 0 to 70 32 F to 158 F OPERATING VOLTAGE 24 VDC ORDERING INFORMATION PART DESCRIPTION 78104700 820 Analog Controller Power supply must be ordered separately 3 24 1 4 Analog input channels On board relays 4 20 mA pass through 3 gas alarm thresholds 1 fault alarm LCD displays concentrations Continuous self checking SPECIFICATIONS HOUSING Wall mounted polycarbonate IP 54 DEFAULT ALARMS Yellow LED Fault detector If you exceed 1 2 hour maintenance operating time GAS ALARMS 3 independent thresholds 3 specific red indicator lights Rising or falling thresholds Automatic or manual clearing on thresholds 1 and 2 automatic clearing on threshold 3 3rd threshold instantaneous based on mean value or time delayed programmable as required Thresholds 1 and 2 comply with control logic of exhaust systems programming AUDIBLE ALARMS Following failure sequence and measurement alarm optional RELAYS 2 independent relays per channel programming on 1st and 2nd threshold Common relay on threshold 3 Common failure relay Fail safe operation in fault Inhibition during mai
75. VDC 50 W output 78101581 Model 6580 400 W 800 W Peak Battery Backup System 78101581 2 Model 6580 400 W 800 W Peak Battery Backup System 2 Batteries 78101581 3 Model 6580 400 W 800 W Peak Battery Backup System 3 Batteries PART DESCRIPTION 71024453 Ammonia Sensor 71024438 Carbon Monoxide Sensor 71024479 Chlorine Sensor 77024511 Chlorine Dioxide Sensor 77024446 Hydrogen Sensor ppm 77024461 Hydrogen Chloride Sensor 77025898 Hydrogen Cyanide Sensor 77024420 Hydrogen Sulfide Sensor 77024404 LEL Catalytic Sensor 71024487 Nitric Oxide Sensor 77024495 Nitrogen Dioxide Sensor 77024412 Oxygen Sensor 77025872 Phosphine Sensor 77024503 Sulfur Dioxide Sensor 77027944 Carbon Monoxide gt Null 7 014314 MI1 Infrared IR Methane calibration Channel 1 7 014314 MI2 LEL Infrared IR Methane calibration Channel 2 77014314 1 LEL Infrared IR Propane calibration Channel 1 77014314 2 LEL Infrared IR Propane calibration Channel 2 REMOTE ALARMS ALARM MODULES NEMA 4X TYPE ENCLOSURE PART DESCRIPTION 77016632 g 24 VDC Audio Visual Alarm Red Lens 77016640 24 VDC Audio Visual Alarm Amber Lens 77016657 24 VDC Audio Visual Alarm Clear Lens 68100296 Alarm Indicating Station 24 VAC Audio Visual Alarm 68100304 Alarm Indicating Station 24 VDC Audio Visual Alarm 68100312 Alarm Indicating Station 120 VAC Audio Visual Alarm 78100054 h 120 VAC Audio Visual Remote Alarm w Silence Switch 78100070
76. X6 also could have CO high 17124975 H H2 17124975 C CO H S 17124975 J PH high 17124975 E LEL Methane 17124975 L CH 0 5 17124975 M CH IR 17124975 N HC IR 17124975 P CO IR 17124975 Q PID 17124975 R also could have 17100967 CO H S 17101106 BM25 also could have LEL 6313888 S N prior to June 08 CO H S 6313823 6313818 SiH 4 6313808 6313803 ETO 6313821 CO high 6313826 AsHs 6313811 PID Available for Europe Please call for information GasBadge Pro also could have H2 17124983 C T82 also could have H 17089947 ATX620 MDU420 CDU440 Infrared IR sensors require factory replacement Low Hydrogen Interference CHLORINE DIOXIDE CHLORIDE PHOSPHINE PHs 17101023 6313810 17124983 9 17078833 17078833 Calibration Equipment or best results use only Industrial Scientific calibration equipment for regular instrument calibration and maintenance All Industrial Scientific calibration cylinders are manufactured to the highest quality standards and include NIST trace able blend techniques analytical leak testing of every cylinder certified component concentrations and clearly marked lot numbers and expiration dates Replacement cylinders are available in a variety of sizes and concentrations for all gases detected by Industrial Scientific instruments See chart on the following pages for ordering information ndustrial Scientific Calibration Kits c
77. adge Pro GasBadge Plus M40 DS2 Docking Station Detailed information is presented on everything from the proper use and operation of the instru ment to specific topics like gas sensor technology and con fined space entry procedures Firefighter Hazard Awareness Course Designed and taught by fire service professionals the course demonstrates how to detect gas hazards commonly encountered in this profession There are 10 online mod ules in this course with a quiz at the end of each module Students successfully completing the final exam at the end of the course will receive a competency certificate All professional online courses are available on Industrial Scientific s Web site at http www indsci com services onlinecourse aspx BOOKS AND GUIDES ONLINE INSTRUMENT TRAINING VIDEOS Industrial Scientific offers free online videos to provide general overview of specific instruments as well as their features and operation These training tools combine video footage with voiceover to guide the viewer through topics like instrument menu navigation remote sampling datalog ging and er Ti calibration TR The videos EE are divided into sever al tutorials which are indexed for easy navi gation and reference Online training videos are available for the following gas detectors on Industrial Scientific s Web site at http www indsci com services training vids aspx MX6 iBrid ITX M4O ATX612 ATX620
78. al Alarm 103 dB b Audible Visual External Alarm 90 dB any instrument models from Industrial Scientific offer datalogging as an option The datalogging feature expands the functionality of the instrument with the ability to store or log the recorded gas readings The stored data can then be used to calculate expo sures during a work shift record peak gas readings or simply identify instrument usage patterns Datalogging Kits include appropriate software connecting cables and information for using the datalogging functions and retrieving stored data DATALOGGING EQUIPMENT DESCRIPTION MX6 iBrid Datalink Software included MX6 iBrid Battery Charger Datalink universal Software included 500 Datalogging Kit Software included included w 18104737 18104414 GasBadge Datalink Software included T82 Datalink Datalogging Kit Software included c M40 Datalink Software included ATX Datalogging Kit Software amp Cable Software included INSTRUMENT MAINTENANCE TOOLS DESCRIPTION PRINTERS PART DESCRIPTION PART 17117722 data dot matrix printer for M Cal Cal Plus 17095746 120 230 VAC powered 17042946 17050278 17049891 17003567 17063256 MX6 iTX VX500 Maintenance Tool 400 300 Series Maintenance Tool LD322 Maintenance Tool STX70 Maintenance Tool 200 Series T82 T80 Maintenance Tool ATX Series Maintenance Tool i eyi Tu M TW TE AT
79. allation up to 256 sensors capable of monitoring 10 different gases 256 addressable relays 64 logic inputs 256 analog outputs Several servo controls can be used low speed high speed delays forced operation night mode etc LOW VOLTAGE DIRECTIVE This device is in compliance with the security requirements of Directive 73 23 EEC modified by Directive 93 68 EEC based on standard 61010 1 and its second amendment METROLOGY Underground parking facilities according to VDI 2053 INGRESS PROTECTION IP54 EMC EN50270 PS M Car Park System MODULE SPECIFICATIONS ORDERING INFORMATION US CPS 10 SENSOR MODULE 6514868 CPS Wall Mounting Control unit 2 086 00 DIMENSIONS 6514869 CPS Rack Mounted Control unit 2 170 00 118 mm x 110 mm x 60 mm 4 65 x 4 35 x 2 36 ee gt gt DEGREE OF PROTECTION IP 54 CPS 10 SENSOR MODULES CABLE GLANDS 2 M16 cable glands 4 8 mm 6513591 CPS 10 Carbon Monoxide Sensor Module 259 00 diameter Power supply local relays 6513592 CPS 10 Nitric Oxide Sensor Module 32900 CONSUMPTION 2 5 mA for the toxic sensor 6513593 CPS 10 Nitrogen Dioxide Sensor Module 329 00 6513594 CPS 100 100 LEL CHa LPG or H Sensor Modules 259 00 STATUS INDICATION specify when ordering AFTER CALIBRATION S Red green electroluminescent diode ACCESSORIES CALIBRATION Automatic non intrusive WCOMCPS Configuration Software including 1 CD 1 USB
80. alogging Kit 120 VAC 18104307 12100 ITX CHa Oz CO Li ion 18104737 230 Charger w Datalogging Kit 230 VAC 18104307 11000 iTX LEL Li ion 18104737 12 iTX Charger w Datalogging Kit 12 VDC 18104307 11126 iTX LEL CO Li ion 18104711 120 Charger Datalink 120 VAC 18104307 11145 iTX LEL CO H2S SO Li ion 18104711 230 iTX Charger Datalink 230 VAC 18104307 11147 iTX LEL CO 5 Li ion 18104711 12 iTX Charger Datalink 12 VDC 18104307 11314 iTX LEL CO H2S NH Li ion 18105379 6 Unit Charger w Flying Leads amp Cradle 18104307 11347 O NH HS Cl Lijon for i TX universal input 18106245 ITX Truck Mount Charger 12V 18106104 ITX Truck Mount Charger hard wired 18104646 ISP Motorized Sampling Pump 18105189 ITX Constant Flow Hand Aspirated Pump 17088618 Rechargeable Lithium ion Li ion Battery Pack 17089376 Replaceable Cell Alkaline Battery Pack 18104687 ITX ISP Nylon Carrying Case 18104703 ITX Leather Carrying Case 16000039 I TX Training Video DS2 Docking Station Ordering Information A Wireless Option currently unavailable 0 none B iGas Reader number included 0 No iGas Readers 1 1 iGas Reader 2 2 iGas Readers 3 3 iGas Readers C Power Cord Option 0 US 1 UK 2 EU 3 AUS 4 ITA 5 DEN 6 SWZ Transportable Area Monitor Powerful audible alarm 103 dB 1m Ultra bright flashing signal viewable
81. ases for a wide variety of hazardous and confined space applications The 40 is housed in a rugged impact resistant case to provide superior performance and durability in harsh environments and resistance to radio frequency and electromagnetic interference Its four button interface provides simple intuitive operation and calibration and the M40 s five second Off feature prevents unintentional shut offs The unit s compact size and economical price make it an ideal personal monitoring instrument Other standard features include a vibrating alarm lithium ion battery peak hold readings large LCD with graphic icons 75 hour datalogging capacity and belt clip An optional compact parasitic sampling pump enables remote sampling from up to 50 feet away The 40 Confined Space Kit provides all the equip ment necessary to operate and maintain the 40 Multi Gas Monitor in everyday confined space applications Each kit includes the 40 monitor 5 40 sampling pump combination carrying case compact charger calibration gas regulator replacement filters and sample tubing everything you need to ensure that the instrument is ready to help keep you safe in the confined space while you focus on getting the job done The 40 carries a two year warranty SUPPLIED WITH MONITOR Compact charger calibration cup tubing leather carrying case suspender clip and instruction manual SUPPLIED WITH MONITOR PUMP COMBINATION Compact
82. at 360 Run time up to 170 hours Over 4 month datalogging capacity e Easily transportable less than 7 kilos Plug and Play Sensors Available O CO H2S LEL SO NO NO HCN HCI Clo ETO PH AsH3 SiH H2 NH PID SPECIFICATIONS CASE MATERIAL he BM25 packs the benefits of a fixed system area Impact resistant polycarbonate monitor into a rugged user friendly and transport DIMENSIONS able instrument It was designed to detect one to five 42 5 cm x 16 cm x 13 cm 16 7 x 6 3 x 5 1 WEIGHT gases for mobile or temporary work applications 6 8 kg 15 Ibs team protection area surveillance or places where DISPLAY READOUT fixed detection systems are not suitable Graphic liquid crystal display w backlight Powered by a NiMH battery pack the BM25 offers SENSORS up to 170 hours of continuous run time Other stan Combustible gas Catalytic Diffusion Oxygen and Toxic gases Electrochemical CO Infrared Isobutylene PID dard features include STEL and TWA values as well as a datalogging capacity of over four months Multiple units can be grouped using optional MEASURING RANGES Combustible Gases 0 to 100 LEL in 196 increments Oxygen 0 to 3096 of volume in 0 196 increments Carbon Monoxide Ammonia 0 to 1 000 ppm in 1 ppm increments Hydrogen Sulfide 0 to 100 ppm in 1 ppm increments Hydrogen 0 to 2 000 ppm in 1 ppm increments Sulfur Dioxide Nitrogen Dioxide Hydrogen Chloride Et
83. bridge POWER SUPPLY AT THE DETECTOR 15 to 30 VDC catalytic 10 to 30 VDC chemical 10 to 26 VDC intrinsically safe transmitter 2 7 VDC max flameproof detector Available Sensors AsH CH Clo CIO CO H2S HCN LEL NO NH O SiHa SO ntrinsically Safe IS and XP approved Corrosion resistant 4 20 mA output Pre calibrated sensor unit P 66 the OLC T 50 a new generation of high quality gas detectors designed for manufacturing plants refineries and other industries to accommodate your gas detection requirements at a great price OLCT 50 Detector The enclosure which is made of alloy AS7 606 is coated with polyester epoxy paint stainless steel is also an option and is rugged and resistant to corrosive agents The OLC T 50 detectors are practical and easy to use The combustible gas sensors are resistant to poisons offer quick response times and provide accurate gas measurement OLCT 50D Detector Based on the OLCT 50 detector transmitter the OLCT 5OD allows the detector unit to be used in a remote mode The detector is equipped with a 15 meter long cable standard and a packing gland for direct connection for detection in difficult locations New Generation New Advantages The detector units which are made of 316L stainless steel are durable and resistant to harsh environmental elements Certified IP 66 OLC 50 and OLCT 50 Se
84. charger calibration cup tubing dust filter water stop suspender clip combo monitor pump leather carrying case and instruction manual SUPPLIED WITH CONFINED SPACE KIT Compact charger calibration cup tubing gas cylinder regulator valve water barrier assembly filter combo monitor pump leather carrying case utility case and instruction manual M40 ORDERING INFORMATION PART 18105437 01111 18105437 01110 18105437 01101 18105437 00110 18105437 01100 18105437 00100 18105437 11111 18105437 11110 18105437 11101 18105437 11100 18105437 10100 M40 KIT 11111 M40 KIT 11101 M40 KIT 11110 DESCRIPTION M40 LEL CO H2S M40 O LEL H2S M40 LEL CO M40 H2S LEL M40 LEL M40 LEL 40 5 40 Pump Combination LEL CO H2S M40 SP40 Pump Combination LEL H2S M40 SP40 Pump Combination LEL CO M40 SP40 Pump Combination LEL M40 SP40 Pump Combination LEL M40 Confined Space Kit w Pump LEL CO HS M40 Confined Space Kit w Pump LEL CO M40 Confined Space Kit w Pump LEL 5 The M40 Confined Space Kits provide all the equipment you need to operate and maintain the M40 Multi Gas Monitor in everyday confined space applications 1 17 he MSHA approved M40 M multi sensor monitor is designed for use in mines and other work environments to assure optimum personal protection against oxygen
85. charging Real time readings on M40 display during calibration 17117722 Serial Data Dot Matrix Printer 120 230 VAC INTERNAL MEMORY 17119843 Replacement Cable for M Cal to Stores up to 150 bump test and calibration reports before overwrite Reports contain serial number time date sensor information pass fail span values and bump values for bump tests Memory will retain 17118118 information when power is off PC Interface 6 Null Modem F F Replacement Power Supply M40 KIT DFRO0000 Accessory Kit demand flow regulator ORDERING INFORMATION calibration gas cylinder tubing 18102187 Calibration Bump Gas 58L PART DESCRIPTION 100 PPM 25 PPM HS 25 LEL pentane O3 18105973 ABX Six Unit M Cal 18102242 Calibration Bump Gas 58L 100 PPM CO 25 PPM HS 50 LEL methane 18105965 10X Single Unit MeCal M40 17124348 Wall Desk Mount Cylinder Holder 18105965 01X 4 Single Unit M Cal M40 SP40 Bay 18102509 Demand Flow Regulator for A of M40 Bays 0 6 58L 103L 34L aluminum cylinders B of M40 SP40 Bays 0 6 X Power Cord 0 N American Plug 1 UK Plug 2 European Plug 3 Australian Plug Note 6 Cal PIUS calibration Station Cal Plus shown with built in printer option for immediate report documentation Cal Plus Calibration Station WE the new Cal Plus Calibration Station calibrating and bump te
86. d Aspirated Pump for GasBadge SAMPLING PROBES 18105155 MX6 Inlet Probe Adapter 18105064 6 High Capacity Filter Adapter 0 1 8 Female Connection 1 1 8 Hose Barb Fitting 2 Female Quick Connect Coupling 3 8 Teflon Probe 4 10 Stainless Steel Probe 5 18 Polycarbonate Probe 17136540 filter cap is required QUESTIONS ABOUT REMOTE SAMPLING Call your local representative or e mail info indsci com Our customer service representatives can answer your questions about remote sampling or provide detailed information about hazardous gases that may be in your workplace environment SAMPLING PROBES PART DESCRIPTION 18102111 f 4 5 Folding Probe w Tubing 18101428 g 4 Polycarbonate Probe w Tubing 18101386 m 6 Extendible Stainless Steel Probe 18102309 h 1 5 Polycarbonate Probe w Filter 18102306 i 3 Stainless Steel Bar Hole Probe w Filter 18102276 1 5 Stainless Steel Flue Gas Probe w Filter to 1 500 F 18102246 3 Extendible Probe w Teflon Tubing Insert 18103309 Aluminum Coiled Probe 800 900 not pictured 18104299 I Polycarbonate Probe w High Capacity Filter 18105239 ATX 90 Quick Disconnect Probe Kit ADDITIONAL REMOTE SAMPLING EQUIPMENT PART DESCRIPTION 18102277 n Inline High Capacity Water Stop 17057803 Replacement Gortex Filter Insert for 18102277 17027152 o Dust Filter Water Stop for Motorized Sampling Pumps 170509
87. d aspirators come with 10 feet of tubing and detailed operating instructions Additional tubing is available for long distance remote sampling Sampling Pumps a SP402 Motorized Sampling Pump b Constant Flow Hand Aspirated Pump c SP40 Motorized Sampling Pump d iSP Motorized Sampling Pump e SP6 Motorized Pump Module ndustrial Scientific sampling probes are available in many sizes and types to best fit the needs of most any remote sampling requirement Probes are used in conjunction with Industrial Scientific sampling pumps or instruments with internal pumps Sampling Probes f 4 5 Ft Folding Probe with Tubing g 4 Ft Polycarbonate Probe with Tubing h 1 5 Ft Polycarbonate Probe with Filter i 3 Stainless Steel Bar Hole Probe 1 5 Ft Stainless Steel Flue Gas Probe k 3 Ft Extendible Metal Probe with Teflon Tubing Insert 1 3 Ft Polycarbonate Probe w High Capacity Filter m 6 Ft Extendible Stainless Steel Probe dequate air flow is critical for proper remote sampling All filters should be replaced when dirt or water inhibits air flow Quick disconnect fittings allow easy no fuss connection to secure tubing to sampling pumps Additional Remote Sampling Equipment n Inline High Capacity Water Stop o Dust Filter Water Stop 0 45 micron for Motorized Sampling Pumps p Inline Dust Filter q Dilution Tube Quick Disconnect Fitting Female s Replacement Filter for i
88. dge Plus LEL Sensor Catalytic Bead of the following of the following of the following of the following the following the following Carbon Dioxide CO Infrared IR 7 Carbon Monoxide CO po e Chlorine Dioxide CIO 7 Ethylene Oxide ETO a Hydrocarbons 0 100 LEL Infrared IR 7 Hydrogen Hydrogen Chloride EE Hydrogen Cyanide HCN X Hydrogen Sulfide H2S LEL Sensor Methane 0 5 Vol Catalytic Bead MEN JN Methane 0 100 Vol Infrared IR Nitric Oxide NO Nitrogen Dioxide NO Sulfur Dioxide SO ENIM VOCs with PID Approvals Independently Classified Intrinsically Safe 4 7 ortable gas monitors from Industrial Scientific Corporation are designed with single goal in mind Preserve human life Each and every day workers depend on our portable gas instruments to warn them of harmful gas conditions To protect them from unseen dangers To help keep them safe Whether for single gas application or a environment requiring multi ring Industrial Scientific instruments are designed and manufactured to deliver peak performance and durability Guaranteed COMPATIBLE GAS MONITORS SUPPORTED 6 all versions iTX Ver 2 2 or higher GasBadge Pro all versions GasBadge Plus all versions CASE Impact resistant composite with radio frequency interference protection DIMENSIONS 24 8 cm
89. dustries Precious Metal Mining and Recovery e Nylon Manufacturing Hydrogen Sulfide H2S Colorless toxic gas with a strong odor of rotten eggs PEL TWA 10 0 ppm STEL 15 0 ppm IDLH 100 0 ppm LEL 4 0 of volume Oil Fields and Refineries Mining and Metals Industries Paper Mills and Leather Tanneries e Water Treatment and Sewer Maintenance Nitric Oxide NO Colorless toxic gas PEL TWA 25 0 ppm STEL N A IDLH 100 0 ppm Diesel Emissions Underground Mining Agriculture Silos e Semiconductor Plants Nitrogen Dioxide NO Reddish brown toxic gas with a pungent odor PEL TWA 3 0 ppm STEL 5 0 ppm IDLH 20 0 ppm e Boilers and Furnaces Diesel Emissions Underground Mining Semiconductor Plants Ozone Colorless blue gas with a very pungent odor PEL TWA 0 1 ppm STEL 0 3 ppm IDLH 5 0 ppm Wastewater Treatment Plants Power Generation e Welding Phosphine PH Colorless gas garlic like odor PEL TWA 0 3 ppm STEL 1 0 ppm IDLH 5 0 ppm LEL 1 79 of volume Pesticides Agricultural Fumigant Doping Agent Sulfur Dioxide SO Colorless toxic gas with a pungent odor PEL TWA 2 0 ppm STEL 5 0 ppm IDLH 100 0 ppm Pulp and Paper Mills Coal Fired Generation Stations e Water Treatment Circuit Board Etching Industry Gas Hazards by Industry HAZARDOUS GAS LLL ee ww ag com SS EB LS wem Mat at ae meses TE meeemamme
90. e Chart ndustrial Scientific offers a variety of calibration gas cylinders and kits including convenient multi gas blends or single gas cylinders Use the following chart to order complete kits or replacement cylinders When ordering cylinders the shaded areas indicate compatible regulators see complete regulator descriptions on page 2 8 while the identifies which regulator is included in the associated kit See Notes for supplementary information 0 5LPM 0 5LPM Demand Flow Regulator Demand Flow Regulator w Regulator Regulator iGas Pressure Switch PART 4 DESCRIPTION 18100883 18100933 18102509 18103564 18105841 18105866 VOL NOTES 18103937 CYL 100 ppm CO 25 ppm H S 19 25 LEL Pentane 000 alumnum O 18102187 CYL 100 ppm CO 25 ppm HS 19 25 LEL Pentane ui mone mE I e Co 18103432 KIT 18102343 18102242 CYL 100 ppm 25 ppm H S 19 2 5 Methane 18102275 KIT 18105262 CYL 50 ppm CO 25 ppm H S 20 9 50 LEL Methane 18108035 8105825 18105536 18105635 18103580 18106179 CYL 100 ppm CO 25 ppm HS 19 O2 50 LEL Propane 18102186 CYL 25 ppm H S 19 25 LEL Pentane 18102188 KIT 18102241 CYL 25 ppm H2S 19 Oz 2 5 Methane 18102274 KIT 18104331 18103143 18103580 8102764 8104448 8104463 CYL 50 ppm CO 1996 O 2596 LEL Pentane 18104455 CYL 50 ppm CO 19 50 LEL Pentane 18101576 CYL 100 pp
91. e and abrasive substances Special Version e Simultaneously optimizes the response to various hydrocarbons meeting the requirements for multi hazard sites Stand alone operation ability Large LCD display Low power consumption Reduced wiring cost Non intrusive operation via intrinsically safe infrared remote control Integrated relays e Direct link 4 20 mA loop and isolated sensor mode OLCT 80 Available Sensors AsHs CIO CO CO Hz null CO H2S HCN LEL NO NO NH O VOC s SiHa SO SPECIFICATIONS HOUSING Stainless steel 316L ENCLOSURE Aluminium DETECTION PRINCIPLES Catalytic Electrochemical Semiconductor MEASURING RANGES Oxygen 0 to 30 by volume Carbon Monoxide 0 to 100 0 to 300 and 1 000 ppm Hydrogen Sulfide 0 to 30 0 to 100 0 to 1 000 ppm Nitric Oxide 0 to 100 0 to 300 and 1 000 ppm Nitrogen Dioxide 0 to 10 and 0 to 30 ppm Sulfur Dioxide 0 to 10 0 to 30 and 0 to 100 ppm Chlorine 0 to 10 ppm Hydrogen 0 to 2 000 ppm Hydrogen Chloride 0 to 30 and 0 to 100 ppm Hydrogen Cyanide 0 to 10 and 0 to 30 ppm Ammonia 0 to 100 and 1 000 ppm Ozone 0 to 1 ppm Phosphine 0 to 1 ppm Chlorine Dioxide 0 to 3 ppm Silane 0 to 50 ppm Arsine 0 to 1 ppm Methane catharometer 0 to 100 by volume Hydrogen catharometer O to 10096 by volume Ammonia catalytic
92. e spirit Xylene Not Detected by a PID Acetonitrile Carbon dioxide Carbon monoxide Ethane Freons Hydrogen Hydrogen bromide Hydrogen chloride Hydrogen cyanide Hydrogen fluoride Methane Nitric acid Nitrogen Oxygen Ozone Sulfur dioxide Water Guide to Hazardous Locations Types of Protection Area Classification IEC Type of Permitted Protection Flammable Flammable Flammable Explosion Protected Gas Group Protection Code Use Standard Principle Mad Material Material Present Present Present I S Output rig ITEM AEX Class Zone 1 FM 3600 ISA 12 16 01 Continuously Intermittently Abnormally EEx e Zone 1 EN 50 019 until July 2006 IEC EU Zone 0 Zone 1 Zone 2 Ex d ia IIC 5 or EN 60079 7 Zone 20 dust Zone 21 dust Zone 22 dust Type of Protection Temperature Class REPERI NI Class Div2 FM 3611 No arcs sparks or NEC9505 one 0 one 1 one Class Zone 2 FM 3600 ISA 121202 ot surfaces 500 2 2 50021 classification 60079 10 U S 505 Ex nA Zone 2 IEC 60079 15 EU classification per EN 60 079 10 American National Standard Grou LS classification per ANSI NFPA 70 National Electric Type of P Explosionproof XP Class L Div EM 3018 222 ya 505 Permitted Class Protection Temperature AEx d Class Zone 1 FM 3600 ISA 12 22 01 Class EEx d Zone 1 EN 50 018 Ex d Zone 1
93. ed instrument simply send the instrument to us and we will repair and return it within 10 days in excellent working order Please visit our Web site for the nearest service center location See product pages for Lifetime Warranty indication PURCHASE OPTIONS AND FTER SALE SERVICE OPTIONS ndustrial Scientific offers many exciting alternatives to purchasing products in a traditional sense These programs available through all Industrial Scientific authorized distributors include Rental Hire For short term gas detection needs equip ment can be rented by the week or by the month Purchase Our products are available for purchase through our worldwide network of distributors To find a local distributor contact the closest regional office or visit our Distributor Locator online at www indsci com Certified Pre Owned Industrial Scientific s Certified Pre Owned Program delivers factory reconditioned instruments to you at discounts of up to 30 off of the list price Instruments are shipped with new sensors bat tery packs and a full warranty sers of Industrial Scientific equipment also have many service programs available to them to simplify their lives and save them money Start Up amp Commissioning Service Our Start Up amp Commissioning Service Technicians can ensure the proper installation of your Docking Station or fixed system Factory Repair Service Industrial Scientific s factor
94. efinition of a Intrinsically Safe Circuit 1996 A circuit in which any spark or thermal effect is incapable of safety causing ignition of a flammable or combustible material in air under prescribed test conditions Reference Library LEL CORRELATION FACTORS The following chart outlines LEL correlation factors for combustible gas sensors installed MX6 Series TMX412 LTX Series LD322 M40 MG140 and 200 Series CALIBRATION GAS Acetone Acetylene Butane Hexane Hydrogen Methane Pentane Propane em e e e wom fe e e e m t 7 c O Example The instrument has been calibrated on methane and is now reading 10 LEL in a pentane atmosphere To find actual LEL pentane please multiply by the number found at the intersection of the methane column calibration gas and the pentane row gas being sampled in this case 1 9 Therefore the actual LEL pentane is 19 10 x 1 9 Calibration gases available from Industrial Scientific Values shown are theoretical and have not been verified through calibration gas testing GAS Reference Library SENSOR CROSS INTERFERENCE TABLE Carbon Monoxide Hydrogen Sulfide Sulfur Dioxide Nitrogen Dioxide Chlorine Chlorine Dioxide Hydrogen Cyanide Phosphine Nitric Oxide Hydrogen Ammonia Carbon Hydrogen Monoxide S
95. er 42 IDS Cluster PART DESCRIPTION MULTI LOCATION COMPANY 1 Meader Illustrates multiple IDS cluster installations at multiple sites all tied 17113630 UPS 700VA 450W together on common company Ethernet sharing common data base Each cluster of IDSs share calibration gas 18105841 Demand Flow Regulator w iGas Pressure Switch Instrument data can be accessed at the plant level as well as by the for 581 103L and 34L aluminum cylinders corporate safety office 18105866 Demand Flow Regulator 600 CGA w iGas Pressure Switch for 34L steel cylinders N OPTIONAL ACCESSORIES Continued 18105833 Demand Flow Regulator 590 CGA w iGas Pressure Switch for 552L cylinders PART DESCRIPTION 18105858 Demand Flow Regulator 330 CGA w iGas Pressure Switch 17113929 4 Port Ethernet Router DSL for 650L cylinders 2 22 22 2 17113887 Ethernet Cable 5 CatbE network cable 18102509 Demand Flow Regulator 5 8 UNF o o o for 58L 103L and 34L aluminum cylinders 17113895 Ethernet Cable 10 Cat5E network cable 18103564 Demand Flow Regulator 600 CGA for 34L steel cylinders 17113903 Ethernet Cable 25 Cat5E network cable 18103549 Demand Flow Regulator 590 CGA for 552L cylinders 17113911 Ethernet Crossover Cable 5 Cat5E network cable 18103556 Demand Flow Regulator 330 CGA for 650L cylinders 17113945 5 Port Ethernet Hub 18105924 5 Port Gas Regulator Manifold 17113952 16 Po
96. ering Information A Wireless Option currently unavailable 0 none C Power Cord Option B number of iGas Readers 0 US 1 UK 0 No iGas Readers 2 EU 3 AUS 1 1 iGas Reader 4 ITA 5 DEN 2 2 iGas Reader 6 SWZ 3 3 iGas Reader DOCKING STATION See Pages 1 2 and 1 3 Gas Badge PIUS Personal Single Gas Monitor SPECIFICATIONS Monitor shown actual size e Low cost CO H2S O2 NO or SO monitoring 2 year continuous monitoring PPM or by volume readout Extremely water resistant third party certified 66 67 User adjustable alarm and calibration gas setpoints Docking Station compatible DOCKING STATION met CASE Rugged water resistant polycarbonate shell with protective concussion proof overmold RFI resistant IP RATING Third party certified IP66 and IP67 water resistant DIMENSIONS 8 13 cm x 4 83 cm x 2 79 cm 3 2 x 1 9 x 1 1 WEIGHT 72 g 2 5 oz SENSORS Oxygen and Toxic Gases Electrochemical MEASURING RANGES Carbon Monoxide 0 to 1 500 ppm in 1 ppm increments Hydrogen Sulfide 0 to 500 ppm in 0 1 ppm increments Oxygen 0 to 3096 by volume in 0 196 increments Nitrogen Dioxide 0 to 150 ppm in 0 1 ppm increments Sulfur Dioxide 0 to 150 ppm in 0 1 ppm increments POWER SOURCE RUN TIME Non replaceable Lithium Battery Maintenance free operation for 2 years TEMPERATURE RANGE 40 to 60 4
97. f tubing replacement sampling pump filters compact charger rechargeable monitor SP40 or 5 40 sampling pump compact charger calibration cup versions only charger datalink ITX Professional kits only calibration cup with tubing gas cylinder regulator valve cell phone style belt clip water barrier tubing calibration gas appropriate mix with regulator spare replaceable cell assembly filter combo monitor pump leather carrying case utility case and alkaline battery pack training video rugged Pelican case instruction manual Add T to part number for 230 VAC charger price is the same PORTABLE INSTRUMENT ACCESSORIES t Industrial Scientific we know that no two working environments are the same Loud T or quiet Hot or cold Indoors or outdoors Confined space or open field No matter what the working environment it s absolutely essential that our customers have the tools to best adapt to their specific situations Industrial Scientific accessories are designed to meet the individual needs of each of these users and enable them to operate with confidence 2 2 S ampling pumps and hand aspirators provide the ability to check for the presence of potentially hazardous atmospheres in a remote area or confined space Motorized pumps include low flow indicators The ISP and the SP402 offer audible and visual low flow low battery and fail warnings All pumps an
98. gative relay security with Fr mini switches Relay modules bu are equipped with 2 all or B n nothing inputs CPS DI16 LOGIC INPUT MODULE DIMENSIONS 125 mm x 165 mm x 60 mm 4 92 x 6 5 x 2 36 NUMBER OF ALL OR NOTHING INPUTS 16 CONSUMPTION 2 mA in normal operation CPS A04 ANALOG OUTPUT MODULE DIMENSIONS 125 mm x 165 mm x 60 mm 4 92 x 6 5 x 2 36 NUMBER OF ANALOG OUTPUTS 4 CONSUMPTION 2 mA in normal operation 3 16 deal for light industrial applications Low cost single gas monitor e Optional on board alarm and relays Wi SPECIFICATIONS CASE NEMA 4 type general purpose indoor use Electroplated for radio frequency interference RFI protection DIMENSIONS 182 9 mm x 142 2 mm x 40 6 mm 7 2 x 5 6 x 1 6 WEIGHT 454 g 16 oz SENSOR TYPE Electrochemical MEASURING RANGES Carbon Monoxide Hydrogen Sulfide 0 to 999 ppm in 1 ppm increments Nitric Oxide 0 to 999 ppm in 1 ppm increments Ammonia 0 to 200 ppm in 1 ppm increments Oxygen 0 to 30 by volume in 0 196 increments Sulfur Dioxide Nitrogen Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments Chlorine 0 2 to 50 ppm in 0 1 ppm increments Chlorine Dioxide 0 to 1 ppm in 0 1 ppm increments Hydrogen Cyanide 0 2 to 30 ppm in 0 1 ppm increments Hydrogen Chloride 0 2 to 30 ppm in 0 1 ppm increments Phosphine 0 to 1 ppm in 0 01 ppm increments POWER SOURCE RUN
99. ge Plus Nitrogen Dioxide 18100050 5 GasBadge Plus Sulfur Dioxide OPTIONAL ACCESSORIES INSTRUMENT mante DESCRIPTION 18107698 ABC DS2 Instrument Docking Station IDS for GasBadge Plus 18106344 0X Plus Calibration Station calibration gas amp regulator not included SOLUTIONS 18106344 1X Cal Plus Calibration Station w On Board Dot Matrix Printer calibration gas amp regulator not included DOCKING STATION X Power Cord 0 N American Plug 1 UK Plug 2 European Plug 3 Australian Plug 18106260 GasBadge Datalink Software included 18106500 GasBadge Constant Flow Hand Aspirated Pump 17121963 GasBadge Neck Lanyard w Safety Release 18106401 GasBadge Plus Nylon Carrying Case 18106419 GasBadge Plus 2 Unit Nylon Carrying Case 17124504 Replacement Water Dust Sensor Barriers 5 count 17117722 Serial Data Dot Matrix Printer 120 230 VAC DS2 Docking Station Ordering Information A Wireless Option currently unavailable 0 none C Power Cord Option See Pages B number of iGas Readers 0 US 1 UK 1 2 and 1 3 0 No iGas Readers 2 EU 3 AUS 1 1 iGas Reader 4 ITA 5 DEN 2 2 iGas Reader 6 SWZ 3 3 iGas Reader 1 16 4 MULTI GAS MONITOR 1 to 4 gas monitoring for O H2S and combustible gases 18 hour runtime with lithium ion battery Includes vibrating 90 dB audible and LED visual alarms M40 SP40 Combination
100. gen Sulfide H2S 6 Nitrogen Dioxide NO 5 Sulfur Dioxide SO 7 Chlorine Cl 6 Nitrogen Dioxide NO 8 Chlorine Dioxide CIO 7 Chlorine 9 Hydrogen Cyanide HCN 8 Chlorine Dioxide CIO A Oxygen 03 9 Hydrogen Cyanide HCN B LEL Infrared factory methane calibration A Oxygen 03 C LEL Catalytic Plug In factory pentane calibration B LEL Infrared factory methane calibration D Carbon Monoxide Hydrogen Null CO H C LEL Catalytic Plug In factory pentane calibration F Hydrogen Chloride D Carbon Monoxide Hydrogen Null CO H G LEL Infrared Propane F Hydrogen Chloride Phosphine PH3 G LEL Infrared Propane L Hydrogen H Phosphine L Hydrogen H C 4 20 mA OUTPUT SCALE FOR SENSOR 1 0 0 999 G 4 20 mA OUTPUT SCALE FOR SENSOR 2 1 0 500 Required only for dual sensor version 2 0 100 0 0 999 3 0 50 1 0 500 4 0 30 2 0 100 5 0 10 3 0 50 6 0 2 4 0 30 7 0 1 5 0 10 8 0 20 6 0 2 9 0 200 7 0 1 8 0 20 D OPTIONAL ON BOARD RELAYS 9 0 200 0 No Relay Modules 1 With On Board Relays COMMON CONFIGURATIONS PART DESCRIPTION PART DESCRIPTION 7814635 1G200 iTrans On Board IR LEL No Relays 7814635 1G201A4 iTrans Dual Unit On Board IR LEL amp No Relays 7814635 11910 iTrans On Board CO w Relays 7814635 23902C2 iTrans Dual Unit Remote amp Remote LEL Catalytic No Relays 7814
101. gs or just the gas type The instrument s two button interface provides intuitive navigation and setup which can be password protected for added security With user adjustable alarm and calibration gas set points the monitor can be customized to any industry or application When gas concentrations exceed the preset limits GasBadge Plus alerts the user with a powerful audible alarm complemented by vibrating and visual alarms The standard confidence indicator automatic self Continued 1 15 test and user activated test provide an extra measure of assurance that the GasBadge Plus is always ready to protect from atmospheric hazards Continuous event logging is a standard feature for the GasBadge Plus with the past 15 alarm events recorded Optional 052 Docking Station Cal Plus calibration station and datalink accessories enable easy instrument maintenance configuration and data downloading Two year warranty SUPPLIED WITH MONITOR Attached suspender clip calibration adapter and instruction manual ORDERING INFORMATION Standard GasBadge Plus configurations are listed below To order the MSHA approved version add an as a suffix to the part number To order the Australian approved version add an as a suffix to the part number PART DESCRIPTION 18100050 1 GasBadge Plus Carbon Monoxide 18100050 2 GasBadge Plus Hydrogen Sulfide 18100050 3 GasBadge Plus Oxygen 18100050 4 GasBad
102. h 24 VDC Audio Visual Remote Alarm w Silence Switch 78100146 120 VAC Audio Remote Alarm w o Silence Switch 78100161 24 VDC Audio Remote Alarm w o Silence Switch 77016814 12 24 VDC Banshee Alarm Fixed Systems Accessories EXPLOSION PROOF ALARMS OLCT IR ACCESSORIES PART DESCRIPTION 177030666 24 VDC AN Alarm Red ATEX EX II 177030674 24 AN Alarm Red Class 1 Div 2 177030682 24 VDC AN Alarm Red Class 1 Div1 177030690 24 VDC AN Alarm Red non classified T77030708 Audible Alarm ATEX EX Il 177030716 Audible Alarm Class 1 Div 1 177030724 Audible Alarm Class 1 Div 2 horn 177030732 Audible Alarm ATEX EX II horn 777030740 Strobe Red Class 1 Div 2 177030757 Strobe Red Class 1 Div 1 777030765 X Strobe Red non classified Industrial ACCESSORIES FOR OLCT 20 40 50 60 80 PART DESCRIPTION 6123716 Sunshield for 300 50 60 80 6147869 Tool Kit for OLC T 20 6147870 Tool Kit for OLC T 50 6155651 Adjustment magnet for OLCT 60 6513539 Calibration Bench type CALIBRO 6797100 Zener Barrier to be mounted in cabinet 6184703 Zener Barrier to be mounted on DIN rail 6797192 Casing for 2 zener barriers 6797547 Casing for 5 zener barriers 6323627 Wall Mounting Gas Collector for OLC T 50 6323626 Ceiling Gas Collector for OLCT 40 6323628 Ceiling Gas Collector for OLC T 50 6329014 Reinforced Splash Guard Kit for OLC T 20 40 50 60 80 6329004 Splash Guard Kit for OLC T 20 40 50 60 80 6331137
103. hange you can always update the agreement by adding instruments to your fleet HASSLE FREE EQUIPMENT UPGRADES iNet makes it easy to take advantage of the latest gas detection technology When renewing your iNet agreement you can either upgrade your fleet with newer instruments or with the existing equipment Equipment Instruments Accessories DS2 Docking Stations Server and software Calibration gas replenishment All repair parts labor and freight Not applicable for iNet Parts Program Setup Services Installation and setup of Docking Stations server and instruments System testing raining Travel expenses Data Services Asset tracking by serial number Secure off site data storage Data analysis E mail reports and alerts Continuous Monitoring Industrial Scientific continuously checks your instrument fleet via the Internet INET SERVICE OPTIONS Choose from one of three service options iNet Exchange Program If a malfunction is detected a ready to use replacement instrument is automatically shipped within 24 hours next business day Customer returns instrument in need of repair back to Industrial Scientific in a pre paid shipping package The iNet Exchange Program is not applicable for fixed point gas monitoring systems iNet Parts Program The iNet Parts Program is ideal for customers that prefer to do their own equipmen
104. hylene Oxide 0 to 30 ppm in 0 1 ppm increments Chlorine Hydrogen Cyanide 0 to 10 ppm in 0 1 ppm increments Nitric Oxide 0 to 300 ppm in 1 ppm increments Phosphine Arsine 0 to 1 ppm in 0 01 ppm increments Silane 0 to 50 ppm in 0 1 ppm increments Carbon Dioxide 0 to 5 of volume in 0 1 increments VOC 2000 ppm equivalent isobutylene in 1 ppm increments POWER SOURCE RUN TIME Nickel Metal Hydride 100 hours typical RECHARGE TIME 4 5 hours typical TEMPERATURE RANGE 20 C to 50 4 F to 122 F typical HUMIDITY RANGE alarm transfer kits This protects larger areas by trans ferring alarms from one 25 to the next An intrinsi cally safe trickle charger is also available for long term area monitoring in classified zones The 25 is durable and versatile It is suitable for a wide range of industries including refineries and pharmaceutical production Applications include turnaround work sites rig overhauls and fence line surveillance SUPPLIED WITH MONITOR Instruction manual calibration adapter universal input charger maintenance tool APPROVALS CE 13 Atex 11 1 EEx ia IIC 4 M1 EEx ia I CSA Class I Groups A B C D T4 Ex ia d IIC T4 C22 2 No 152 excluding aspirated and PID sensor configurations 15 95 RH non condensing continuous typical PID sensor only availabele for Europe Please call for information 1 11 ORDERING INFORMATION 6514872 ABCDEF A E Available Sensors
105. i yx oae S ET f d du 5 aK bu TEL gt Rea a Au i rb jl pal Tfi EL uk wu 7 A PAM n AAN 4 mn 47 Pier 1 1l TT 1 orent Whether for single application Or to encompass multiple rooms and areas our fixed point monitoring solutions are developed to meet the individual needs of our customers In fact when you contact us for information about our fixed systems chances are we ll ask you a lot more questions than you ll ask us What gases do you need to monitor What other background gases may be present in the area you are monitoring What is the size of the area being monitored Where do you expect to experience problem What is the typical air flow direction in the area to be monitored At Industrial Scientific application oriented solutions are our goal for every product we sell Need the best solution for your application Call 1 412 788 4353 Our customer service representatives will take the time to answer all your questions and ask the right ones j P g ag 1 IRE ETC e PV UE kir U CULEX Fixed Point Monitors Low cost fixed point monitors with choice of sensor options Unique dual sensor platform on board amp remote placement 4 20 mA and ModBus RTU interface for direct communication to control device or PLC Highly vis
106. ible split screen LED display 1 SPECIFICATIONS ENCLOSURE MEN Cast aluminum poly bonded coating explosion proof NEMA 7X he iTrans fixed point gas moniter provides one IP66 rating or two points of detection from a single head for SENSORS maximum flexibility superior performance and lower Combustible Gases Catalytic bead and or installation costs The three or four wire system allows Non Dispersive Infrared NDIR Oxygen and Toxic Gases Electrochemical diffusion gas sensors to be mounted on board or remotely up to MEASURING RANGES 200 meters away and can accommodate more than 200 Combustible Gases 0 to 100 LEL in 1 increments transmitters in 85485 bus configuration Our industry NN DN proven smart sensor technology allows iTrans to Oxygen 0 to 30 by volume in 0 196 increments p uu Ammonia 0 to 200 ppm in 1 ppm increments monitor a wide range of gases for specific applications Carbon Monoxide 0 to 999 ppm in 1 ppm increments Safety features include zero and cal fault protection and Hydrogen Sulfide 0 to 500 ppm in 1 ppm increments ad Sulfur Dioxide 0 2 to 99 9 ppm in 0 1 ppm increments access code security all enclosed within an explosion Hydrogen Cyanide 0 2 to 30 ppm in 0 1 ppm increments proof aluminum housing Hydrogen Chloride 0 2 10 90 im 0 1 ppm increments The microprocessor controlled transmitters can Phosphine 0 to
107. icing available through authorized distributors Environmentally Friendly Complete recycling process for returned and decommissioned instruments Recycling program for sensors PC boards and batteries Compliant with WEEE and RoHS THE NDUSTRIA Durability and Reliability Durable stainless steel or high impact composite construction on portable monitors NEMA 4X fiberglass cast aluminum or stainless steel construction on fixed monitoring systems Superior Radio Frequency Interference RFI and Electromagnetic Interference EMI shielding State of the Art Product Testing Laboratory Tests simulate harsh industrial environments for product design verification Rigorous testing for RFI EMI water and dust ingress vibration and drop effects temperature and humidity Ensures product reliability and durability 1 800 sq ft in house lab is unique to the industry Flexible Programs On site product demonstrations raining courses available at corporate headquarters or customer s site Interactive computer based and Web based training Variety of options for purchase and after sale service GUARANTEED 1509001 2000 NET INSTRUMENT NETWORK magine a workplace that is safer more productive more cost effective The iNet Instrument Network gives you better visibility into the effectiveness of your gas monitoring program by combining patented technolog
108. ing your gas monitors wherever you use them The DS2 gives you all of the benefits of consistent automated calibration record keeping battery recharging and instrument diagnostics for your moni tors to limit your liabilities and safety hazards Ethernet connectivity enables you to link up to 100 stand alone Instrument Docking Stations IDSs from anywhere in your facility and relay the data back to one central data base for total instrument management A graphical user interface tool DSSAC allows an administrator to view operations on each Docking Station from a network com puter making it easy to track instruments print reports set events and change parameters for any location Each IDS features a multilingual display three status LEDs a keypad and an audible alarm to provide impor tant instrument details at a single glance The DS2 also offers optional iGas capability to automatically identify calibration gas cylinder concentrations lot numbers and expiration dates on the system Whether you manage one gas monitor or an entire fleet the DS2 provides superior cost savings and flexibility SUPPLIED WITH 052 DOCKING STATION Each DS2 Instrument Docking Station is shipped with DSS software 2 DSSAC licenses Docking Station configurator power cord installation guide and operating manual 052 Docking Station SMALL INSTALLATION SCENARIO Ethernet Hub SINGLE LOCATION COMPANY Illustrates one 052 installation on
109. insically Safe Trickle Charge Kit Cable length 50 m one IS power supply and wiring arrangements 6311093 25 Intrinsically Safe Trickle Charge Kit Cable length 100 m one IS power supply and wiring arrangements and wiring arrangements Gas Badge Pro Single Gas Monitor Monitor shown actual size Interchangeable smart sensors monitor oxygen or any one of many toxic gases One year datalogging capacity minimum Standard STEL and TWA Docking Station compatible Lifetime warranty DOCKING STATION iNet SPECIFICATIONS CASE Rugged water resistant polycarbonate shell with protective concussion proof overmold RFI resistant DIMENSIONS 9 4 cm x 5 08 cm x 2 79 cm 3 7 x 2 x 1 1 WEIGHT 85 g 3 oz SENSORS Oxygen and Toxic Gases Electrochemical MEASURING RANGES Carbon Monoxide 0 to 1 500 ppm in 1 ppm increments Hydrogen Sulfide 0 to 500 ppm in 0 1 ppm increments Oxygen 0 to 3096 by volume in 0 196 increments Nitrogen Dioxide Sulfur Dioxide 0 to 150 ppm in 0 1 ppm increments Ammonia 0 to 100 ppm in 1 ppm increments Chlorine 0 to 100 ppm in 0 1 ppm increments Chlorine Dioxide 0 to 2 ppm in 0 01 ppm increments Phosphine 0 to 10 ppm in 0 01 ppm increments Hydrogen Cyanide 0 to 30 ppm in 0 1 ppm increments Hydrogen 0 to 2 000 ppm in 1 ppm increments POWER SOURCE RUN TIME User replaceable 3V CR2 Lithium battery 2 600 hour run time
110. ions Operational testing End user training ndustrial Scienfic offers complete custom solutions for flame and gas detection needs Our team of engineers works directly with customers from system conception design installation commissioning and servicing Each application is optimized for performance and cost Each control system is fully documented and delivered ready for installation A full set of documentation is included with wiring diagrams system layout customized user manual test reports control unit programming and user manuals for each flame detector and gas monitor Our on site service and commissioning guarantees that the system is up and running properly upon completion Other after sales services such as quarterly calibrations of the transmitters are also available from Industrial Scientific FIXED SYSTEMS COMMISSIONING SERVICES Available for Industrial Scientific fixed point industrial monitoring systems and AirAware commercial monitors e Verify proper device terminations Controller programming Initial calibration Employee training e Contractor coordination and logistics On site project management TRAINING AND REFERENCE LIBRARY 592 TRAINING SERVICES ow do electrochemical sensors work What should you know about working with toxic gases How will the most recent government regulations affect your daily operations How can proper instrument mainte nance
111. l printer Analog input Module 3 Analog signals from the detectors to be input into the control system Dual converters ensure reliable and redundant operation Direct connection with the MX 62 system or remote via the adapter module Up to 8 measurement points 2 or 3 wire Adapter Module 3 Allows 3 operating modes Up to 16 addressable detectors in a loop configuration Up to 8 addressable detectors combined with a remote analog module Connection of 2 analog input modules The module be remote via 2 RS485 networks 2 x 4 wires screened system Relay Module 9 Fitted with 2 processors linked with the CPU Principal module 8 relays Extension module 8 relays NO NC contacts Breaking capacity 460 VA 60 W Positive safety individually programmable The module can be remote via 2 RS485 2 x 4 wires screened system Analog Output Module 2 Fitted with 2 processors linked with the CPU Fitted with 8 analog 4 20 mA or 0 10 V outputs Each output is programmed to transmit The real time value for one each input linearized value Means or max for a detectors group Mimic module open collector 56 suitable to drive LED mimic panel as per MX 62 channels Communication Module Link to a supervisor for data exportation PLC DCS or SCADA Link with CPU via the RS 232 Personalized or ModBus protocol via RS 422 Optional communication splitter module avai
112. lable 3 20 4800 Controlfer 0 ne E ES no E C E m SPECIFICATIONS ENCLOSURE NEMA 4X ABS plastic enclosure ANALOG INPUTS 8 48 analog inputs 8 per card 4 20 mA 0 20 mA 0 1V 0 5V 0 10V 1V 5V 10V DIGITAL INPUTS 0 72 digital ModBus RTU inputs OUTPUTS Fully programmable relay outputs 4 per card DISPLAY LCD display for programming and viewing channel information Tri color LEDs for each analog input and relay output to show status of channel ALARM NOTIFICATION LCD alarm notification LED alarm notification audible alarm notification via local speaker telephone dial out notification PROGRAMMING INTERFACE Local keypad or remotely via telephone EVENT LOG Stores 1 000 entries Entries include entering and leaving alarm states peak readings and calibrations TEMPERATURE RANGE 40 F to 185 F 40 C to 80 C OPERATING POWER RANGE 100 240 VAC 15 18 VDC on board battery backup 8 48 analog inputs Up to 72 digital ModBus inputs e Programmable relay outputs Telephone alarm notification 1 000 entry event log ModBus master or slave device Printer interface Easy channel configuration via local keypad or telephone he 4800 Controller from Industrial Scientific is an 8 48 analog input controller With its optional on board relays the 4800 can control alarms fans horns etc when alarm conditions are reached Being fully programmab
113. le relays can be set to activate from multi ple channels or multiple relays can be programmed to a single channel Time delays can also be programmed for each relay This allows the relays to activate after alarm conditions are met for specified periods or de activate after a specified time prior to an alarm Along with monitoring analog signals the 4800 Controller can also monitor up to 72 digital ModBus RTU inputs The 4800 can be set up as a ModBus RTU master unit to monitor these channels or it can be set up as a ModBus RTU slave device As a ModBus RTU slave device the 4800 Controller can communicate to SCADA HMI and PLC controlled systems With a telephone line interface the 4800 Controller has remote call out capabilities This allows the control ler to phone fax or page alarm notifications to users Phone lists are user programmable and can be entered in a priority The 4800 can also be remotely programmed via the telephone To keep track of events the 4800 Controller has a built in event log The event log will store 1 000 events Events consist of calibrations peaks and alarms The event log can be viewed via a local printer connected to the 4800 Controller or through a PC 48 0 0 Controller The 4800 Controller is an analog digital input output system controller with remote dial out and access capabilities The base unit consists of a micro controller with display modem AC and phone line surge protection and 24
114. lity Use the following guide to select the options that best fit your monitoring needs and applications Industrial Scientific recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements iTrans Base Part Number 7814635 ABCDEFG sensor options as listed below Dual reading LED display magnetic calibration tool and calibration cup are standard items with all iTrans monitors Ordering example An iTrans with an on board LEL 4 20 mA scale 0 100 and remote mount HS 4 20 mA scale 0 500 with optional relays would have a part number of 7814635 1C21241 ITRANS PART NUMBER ORDERING MATRIX A SENSOR 1 CONFIGURATION E SENSOR 2 CONFIGURATION 1 Explosion proof On Board 0 No Sensor 2 Explosion proof Remote max distance 200m 1 Explosion proof On Board 3 Non Hazardous Remote Duct Mount 2 Explosion proof Remote max distance 200m 4 Explosion proof On Board With Splash Guard 3 Non Hazardous Remote Duct Mount 5 Explosion proof Remote With Splash Guard 4 Explosion proof On Board With Splash Guard max distance 200m 5 Explosion proof Remote With Splash Guard max distance 200m B GAS SENSOR 1 1 Carbon Monoxide CO F GAS SENSOR 2 Required only for dual sensor version 2 Nitric Oxide NO 1 Carbon Monoxide CO 3 Ammonia NH3 2 Nitric Oxide NO 4 Hydrogen Sulfide H2S 3 Ammonia NH3 5 Sulfur Dioxide SO 4 Hydro
115. m CO 19 25 LEL Pentane 18101568 KIT 18102269 KIT 18101253 CYL 100 ppm CO 19 25 LEL Pentane 18101295 KIT 18105676 CYL 100 ppm CO 15 25 LEL Pentane 18102324 CYL 250 ppm CO 19 25 LEL Pentane 18102243 CYL 50 ppm 19 2 5 Methane 18102165 CYL 100 ppm CO 19 2 5 Methane 18102270 KIT 18101246 CYL 100 ppm CO 19 2 5 Methane 18101287 KIT 18107847 CYL 100 ppm CO 19 2 0 Methane 18105122 CYL 50 ppm CO 18 50 LEL Propane 18101238 CYL 19 O 25 LEL Pentane 18101279 KIT 19 25 LEL Pentane 25 ppm H2S 103L CYL 100 ppm CO 2 5 25 ppm H S 19 25 LEL Pentane 18103473 CYL 100 ppm CO 2 596 CO 1996 2596 LEL Pentane 18103317 KIT 18104521 CYL 100 ppm CO 5 19 25 LEL Pentane 18104539 KIT 18106799 18106807 810691 810677 8106781 18108571 CYL 100 ppm CO 5 ppm 19 2 5 LEL Methane 18108548 18105593 18102147 KIT NOTE Calibration gas cylinder expiration times vary due to gas type Please contact Industrial Scientific for detailed information CO r e Co sau gt E NENNEN En w CGA 600 fitting 1000 gt r DI CO CO r PT r e CO w 103L Zero Air 34L w CGA 600 fitting w 34L Zero Ai FE F 3 L e
116. make your instruments easier to use and more cost efficient The Training Department at Industrial Scientific exists to provide valuable information to our customers or any interested company or individual Our courses are designed to help seasoned veterans as well as newcomers and are informative useful educational and even enjoyable Most important our courses will give you a better understanding of the dangers associated with hazardous gas atmospheres and help you use our instruments more effectively and safely We offer comprehensive Gas Detection Seminars focusing on gas hazards sensor technology calibration maintenance battery handling instrument use OSHA regulations Permit Required Confined Spaces CFR 29 191 146 and other government laws as well as hands on training Conducted by highly qualified instructors Industrial Scientific training courses are offered at our headquarters in Oakdale Pennsylvania Arras France and several other convenient locations throughout the U S and Canada We can even provide customized on site sessions tal lored to meet your company s specific training needs We now offer competency certification for anyone attending our Gas Detection Made Easy courses More than just a certificate of attendance you are tested to ensure that you were effectively trained and will leave with a Competent Person Certificate as required in some regulatory standards For a complete list of course dates a
117. n Chloride D Carbon Monoxide Hydrogen Null CO H G LEL Infrared Propane F Hydrogen Chloride Phosphine PH3 G LEL Infrared Propane L Hydrogen H Phosphine PH3 L Hydrogen H C 4 20 mA OUTPUT SCALE FOR SENSOR 1 0 0 999 G 4 20 mA OUTPUT SCALE FOR SENSOR 2 1 0 500 0 0 999 2 0 100 1 0 500 3 0 50 2 0 100 4 0 30 3 0 50 5 0 10 4 0 30 6 0 2 5 0 10 7 0 1 6 0 2 8 0 20 7 0 1 9 0 200 8 0 20 9 0 200 D OPTIONAL POWER SUPPLY 0 No Power Supply 1 With Optional Power Supply COMMON CONFIGURATIONS PART DESCRIPTION PART DESCRIPTION 7814783 1 410 iTrans Alarm On Board w Power Supply 7814783 11011C2 iTrans Dual Unit Alarm On Board CO and LEL w Power Supply 7814783 1C210 iTrans Alarm On Board LEL w Power Supply 7814783 14110 iTrans Alarm On Board H5S w Power Supply 7814783 1C211A4 Trans Dual Unit Alarm On Board LEL amp w Power Supply 7814783 14111A4 iTrans Dual Unit Alarm On Board H2S and w Power Supply 7814783 1C21141 iTrans Dual Unit Alarm On Board LEL amp HS w Power Supply 7814783 2C210 iTrans Alarm LEL Remote w Power Supply 7814783 1D010 iTrans Alarm On Board CO H Null w Power Supply 7814783 2C212A4 Trans Dual Unit Alarm Remote LEL and w Power Supply Cabling must be ordered separately for remote sensors Consult factory for availability additional gases ranges and certification information Subjec
118. n ionene 8 MEE NEM ovo L 1 34 jalminm 1 I 650L w CGA 660 fitting nz Oo oe rc 18107730 CYL 25ppmNO 222212212 6500 w CGA 660 fitting 18105817 CYL 10ppm S02 _ o 6500 W CGA 660 fitting NOTE Calibration gas cylinder expiration times vary due to gas type Please contact Industrial Scientific for detailed information CO r Miscellaneous Accessories t Industrial Scientific we know that no two working environments are the same Loud or quiet Hot or cold Indoors or outdoors Confined space or open field No matter what the working environment it s absolutely essential that our customers have the tools to best adapt to their specific situations Industrial Scientific accessories are designed to meet the individual needs of each user and enable them to operate with confidence EXTERNAL ALARMS PART DESCRIPTION PART 18103747 a 103 dB Latching External Alarm for i TX VX500 600 18107086 400 300 200 Series except OX231 18107094 18101154 b 90 dB External Alarm for 600 400 300 200 Series except OX231 18104786 18101394 External Alarm Extension Cable 6 1 m 20 18106260 18101600 External Alarm Extension Cable 15 25 m 50 18104281 18101618 External Alarm Extension Cable 30 5 m 100 18105528 18103069 ndustrial Scientific s external alarms provide additional protection in high noise work environments External Alarms a Audible Visual Latching Extern
119. nd availabilities or for more information on customized sessions contact our Training Department by e mail Training indsci com or visit our Web site at www indsci com Confined space simulator FACE TO FACE TRAINING COURSES R egular training ensures that workers will know how to safely evaluate and respond to gas hazards and confined space risks common in many industries Industrial Scientific offers several classroom training programs developed by experts familiar with instrument applications government regulations and monitoring techniques The courses combine theory with hands on exercises for a variety of gas detection topics outlined below Classes are held on site or at regional locations throughout the year Contact the nearest Industrial Scientific office or visit www indsci com for dates and locations Portable Instrument Operations Level Training Designed to empower the gas monitor end user with knowledge on all issues related to gas monitoring Portable Instrument Technician Level Training Offered for individuals responsible for maintaining and repairing their Industrial Scientific equipment Confined Space Metering Class This workshop is focused exclusively on safe appli cations in confined space environments Every detail is covered in the classroom before apply ing that knowledge in our on site confined space simulator Firefighter Awareness Class Taught by firefighters this course deliver
120. nection 4800 16000000 4800 Controller 48 Analog Inputs No Relay Outputs 4800 10090410 4800 Controller 72 Digital ModBus Inputs 16 Relay Outputs Datalogging 3 22 2 16 Analog input channels On board relays SIL2 gas alarm thresholds one with time delay 1 common fault alarm SPECIFICATIONS CAPACITY Up to 16 channels 8 cards ordered separately 2 channels per card DISPLAY Fluorescent 2 lines of 16 fixed or scrolling characters FAULT ALARMS Fault interface link detector microcontroller common fault relay GAS ALARMS 3 independent thresholds per channel Third threshold delayed or averaged Automatic or manual reset Programmable increasing or decreasing alarm Relay output per channel alarm 1 and 2 common relay on alarm 3 AUDIBLE ALARMS 80 dB at 30 cm RELAYS 2 independent gas alarm relays per channel 1 common gas alarm 3 relay or common audible alarm transfer 1 common fault relay Programmable positive or negative safety on alarm relays Fail safe on fault Programmable NC or NO output on alarm 1 alarm 2 and fault alarm SPDT on alarm 3 SIGNAL OUTPUT Analog 4 20 mA per channel Serial RS 485 or 232 ModBus protocol OPERATING TEMPERATURE 10 C to 45 C 14 F to 113 F HUMIDITY RANGE Relative humidity 5 to 95 uncondensed COMPLIANCE European Standards 50054 50081 and 50082 ORDERING INFORMATION PART DESCRIPTION W521020 Frame Rack 3 1
121. ng event logs and datalog data or changing instru ment settings while the instrument battery charges Single unit and 5 unit charger versions all have universal power adapters included for global requirements Truck mounted chargers not shown are also available in your choice of a standard cigarette lighter adapter or hard wired options These options provide convenience where instrument use is based out of a vehicle such as a fire engine or utility truck Replaceable cell alkaline battery packs and an extended range 36 hours typical lithium ion battery pack provide flexible options and back up power in emergency situations a MX6 Replacement Battery Charger b MX6 Battery Charger 5 Unit shown with MX6 Unit not included c MX6 Battery Charger Datalink universal he ITX Charger Datalink accessories provide the ability to charge the lithium ion battery packs in 5 hours or less in or out of the instrument and serve as the instruments communication link to a personal computer The chargers are available with or without the datalogging kit which allows users to download hygiene data Replaceable cell alkaline battery packs provide backup power in emergency situations Single unit and 6 unit chargers not shown are also available for the iT X monitors in your choice of voltage options d Single Unit Universal Compact Charger for iTX e Charger Datalink f ITX VX500 Alkaline Battery Pack g ITX VX500 Recha
122. ns and contractors to perform installation and troubleshooting procedures Our Start Up and Commissioning Services are available to you on site for Industrial Scientific fixed point monitoring systems solar and wireless applica tions AirAware commercial and non hazardous moni toring systems the Docking Station a calibration and management system for portable gas monitors Industrial Scientific s expertly trained technicians ensure that your systems are installed correctly and in proper operating order we even provide the necessary training so that employees are never left guessing about proper maintenance and instrument calibrations Our Commissioning Services are easily customized for your company s specific needs giving you the flexibility to create a program that works with your employees resources and budget And of course you also have the option of adding other convenient Industrial Scientific maintenance calibration leasing and on site services to your gas detection program Contact your local distributor or Industrial Scientific for a customized quote for your specific Start Up and Commissioning needs DOCKING STATION COMMISSIONING SERVICES Available for the Docking Station an automated calibration and maintenance station for Industrial Scientific portable gas monitors All hardware installations and connections Any necessary instrument microprocessor updates All software configurat
123. ntenance function INPUT MEASUREMENT 1 flammable toxic gas or oxygen detector per channel Up to 5 CO detectors per channel parking garage version Loop line resistance Flammable 3 wire 16 500 m of cables 1 5 mm 4 20 mA 2 wire 32 1 000 m of cables 1 5 mm SIGNAL OUTPUT 4 20 mA per channel load resistance 600 max DIMENSIONS 29 5 cm x 34 cm x 10 7 cm 11 61 x 13 39 x 4 21 WEIGHT 5 48 kg 12 08 Ib OPERATING TEMPERATURE 10 C to 50 C 14 F to 122 F he MX 42A gas and flame measurement and alarm control unit ensures the safety of your personnel working in environments which may contain explosive or toxic gases The MX 42A is connected to the corresponding detectors to efficiently solve your gas detection problems whether in industrial or commercial applications The control unit can accommodate one to four sepa rate channels to provide a customized detection system Flexibility The MX 42 A can be fitted with one detector per channel The detection capability is tailored to your requirements and ensures effective detection and preven tion The alarm is triggered as soon as the value measured on one of the channels exceeds the corresponding setpoints The relay or relays activate alarms or secondary control systems The third alarm threshold can be programmed for delayed or average value Enhanced ergonomics and performance User friendly Easy to program Wall mounted housing
124. ock for FLP OLCT 20 50 60 80 6313666 NH 05 000 ppm Catalytic sensor for 300 6313716 5 0 30 ppm sensor block for IS OLCT 20 50 60 80 6313760 055 000 ppm Catalytic sensor for OLC 20 6313717 H2S 0 100 ppm sensor block for IS OLCT 20 50 60 80 6313707 NH 0 100 ppm sensor block for FLP OLCT 20 50 60 80 6313718 5 0 1 000 ppm sensor block for IS OLCT 20 50 60 80 6313708 NH 0 1 000 ppm sensor block for FLP OLCT 20 50 60 80 6795577 NO NO sensor 0 100 ppm or 0 300 ppm or 0 1 000 ppm 6313894 NH 0 5 000 ppm sensor block for OLCT 20 50 60 80 6313728 NH 0 100 ppm sensor block for IS OLCT 20 50 60 80 on NO Sensor O 100 ppr Tor 204A 6313729 NH 0 1 000 ppm sensor block for IS OLCT 20 50 60 80 Salang NO Sensor ak das 6313895 0 5 000 ppm sensor block for IS OLCT 20 50 60 80 oid 8 6113319 CO sensor 0 100 or 0 300 or 0 1 000 ppm for 6313636 NO sensor 0 100 ppm for CTX 300 6797574 CO sensor 0 100 or 0 300 or 0 1 000 ppm 3 EF for CTX 6313637 NO sensor 0 300 ppm for CTX 300 6113308 CO sensor 0 10 3 H for CTX 6313638 NO sensor 0 1 000 ppm for CTX 300 6793285 CO sensor H null for CTX 6313698 NO 0 100 ppm sensor block for FLP OLCT 20 50 60 80 Fixed Systems Accessories REPLACEMENT SENSORS FOR OLC OLCT CEX CTX PART DESCRIPTION PART DESCRIPTION 6313699 NO 0 300 ppm sensor block for FLP OLCT 20 50 60 80 6314002 sensor 0 30 ppm for CTX 300 6313700 NO 0 1 000 ppm sensor block for FLP OLCT 20
125. ome equipped with everything necessary to keep your gas monitoring instruments operating accurately and reliably Kits contain certified NIST traceable National Institute of Standards amp Technology span gases for safe reliable instrument calibration Complete kits are available for all installed sensors and include e Convenient Carrying Case e Non refillable Cylinders Flow Regulator REGULATORS egulators provide the proper flow rate for calibrating your Industrial Scientific instrument Always make certain to use the appropriate regulator for the application as recommended in the Instruction Manual a 34 L Regulator 1 2 L min flow b 58 103 L Demand Flow Regulator c 34 L Demand Flow Regulator d 552 L Regulator 1 2 L min flow D m 4 i Li m nt f 58 103 L Ammonia Regulator g 58 103 L Bump Test Regulator MISCELLANEOUS CALIBRATION EQUIPMENT PART DESCRIPTION PART DESCRIPTION 18100933 34L Regulator 1 2L min flow 17041807 Calibration Log tablet of 50 sheets 18102509 0 58 1031 Demand Flow Regulator 34L Aluminum Cylinders 17050734 Calibration Log TMX LTX STX tablet of 50 sheets 18103564 341 Demand Flow Regulator CGA 600 17045873 Calibration Label 18103549 5521 Demand Flow Regulator CGA 590 17050831 Calibration Cup 300 Series 18103556 6501 Demand Flow Regulator CGA 330 17042839 Calibration Cup 400 Series 18104158 Demand Flow Regulato
126. oring needs change the iTX can go from being a single gas unit to a six gas monitor or anything in between Featuring smart sensor technology the provides simpli fied single button operation and calibration functions A Quick Cal feature quickly calibrates up to four sensors at once saving time and calibration gas costs With the Docking Station it s even easier The ITX features a backlit dot matrix LCD that simul taneously displays all gases monitored ultra bright visual alarms and a powerful 90 dB audible alarm all encased in a compact rugged stainless steel housing to provide maximum durability and RFI protection All units offer datalogging of up to 300 hours of survey data at one minute intervals STEL TWA and peak readings and user site ID data entry iButton technol provides automatic field entry for data input Designed to be versatile and intuitive the i TX allows the user to reconfigure the monitor to meet their changing needs Instrument settings default to the most common choices while the ultimate flexibility is found in the custom selections for 24 configurable parameters including security code settings alarm options and calibration preferences Lifetime Warranty SUPPLIED WITH MONITOR Battery pack as ordered nylon carrying case calibration cup with tubing maintenance tool instruction manual and start up card I TX multi Gas Monitor iTX has many o
127. otective concussion proof over mold protects the unit from extreme abuse in a variety of harsh industrial environments simple and intuitive four button navigation allows easy access to setup operation and calibration functions At 85 grams 3 ounces the instrument s compact size and light weight allow it to be worn comfortably with a variety of clip attachments With the top mounted sen sor the unit can also provide continuous and unobstruct ed protection even when placed in a shirt pocket Continued The large LCD display includes a backlight for clear display visibility in low light conditions and international graphic symbols for easy operation The GasBadge Pro can be configured to display gas readings in percent by volume or in parts per million and is capable of show ing both gas type and direct gas readings or just the gas type The instrument s four button interface provides intuitive navigation and setup which can be password protected for added security Designed to provide protection for a minimum of 2 600 continuous hours with a replaceable CR2 Lithium battery the GasBadge Pro will alert the user with a pow erful audible alarm complemented by vibrating and visual alarms when gas concentrations exceed the preset limits The standard confidence indicator automatic self test and user activated test provide an extra measure of assurance that the GasBadge Pro is always ready to protect from atmospheric hazards
128. our Industrial Scientific equipment A cost effective solution for managing one monitor or an entire fleet of monitors the 052 modules can be placed practically anywhere you use your equipment See page 4 4 for information on Docking Station Start Up Services offered by Industrial Scientific The Extended Warranty Program is designed to secure customers cost of ownership for instruments with lim ited warranties non guaranteed for life equipment This additional coverage extends the warranty to a full four years and must be purchased within the first six months of instrument ownership 4 3 THE iNet SOLUTION he iNet Instrument Network is a comprehensive solution for ownership repair and maintenance of all your gas monitors More than just an outsourcing option iNet gives you better visibility into the effectiveness of your gas monitoring program by combining patented technology automation and industry best practices What iNet Does Performs instrument bump tests calibrations and data downloads Analyzes instrument data Generates scheduled reports so you can address unsafe conditions or at risk behavior before problems happen Sends immediate alerts dentifies service requirements e Automatically initiates an instrument exchange replacement part or on site repair service An All inclusive Program Equipment Instruments and accessories DS2 Docking Stations server and
129. our gas detection program on budget by eliminating unplanned expenses caused by damage or loss Rental Hire Industrial Scientific s rental program is ideal for customers who need additional monitors for special projects such as turnarounds or shutdowns but don t want to purchase them The program offers flexible rental periods and rates from weekly monthly to long term All of our instruments are available for rent in any quantity and are customized to fit your specific needs They arrive calibrated and ready to use Purchase Our products are available for purchase through our worldwide network of distributors To find a local dis tributor contact the closest regional office or visit our Distributor Locator online at www indsci com Certified Pre Owned Industrial Scientific s Certified Pre Owned Program deliv ers factory reconditioned instruments to you at discounts of up to 30 off of the list price Instruments are shipped with new sensors battery packs and a full warranty The DS2 provides automated instrument management and diagnostic functions ndustrial Scientific designs and manufactures the high est quality gas detection equipment in the industry But our commitment to quality doesn t end once the instru ments are shipped If your Industrial Scientific instrument does need to be repaired there will be no compromise on quality and no guessing about what is covered under warranty since many of our portable in
130. phanumeric LCD remote and optional PRINTER PROGRAMMING Centronix connection Various possibilities voting boolean calculations increasing and POWER SUPPLY decreasing alarms mean etc VISUAL ALARMS 24 VDC 230 VAC others on demand Dual power supply Gas 4 thresholds OPERATING TEMPERATURE Maintenance 15 C to 50 C 5 F to 122 F calibration mode STANDARD fault 5113 of EN 954 1 and BSV 03 002 aedi d RACK DIMENSIONS H from 3U x L 19 x P 12 cm AUDIBLE ALARMS Via specialized relays M 2 Controller VARIOUS MODULES LED Module O 16 channels 8 channels standard 4 alarm thresholds Reset acknowledge Power on Fault LCD Module 3 Up to 30 displays can be networked with the MX 62 allowing measurement display wherever you require Graphic alphanumeric high definition LCD User friendly display graphics Data storage at least 5 days option Can be remote via RS 485 Printer Module 9 Printing alarms relay operating status fault min max average over 8 hours Type ASCII alphanumeric 40 or 80 characters Parallel connection CPU Module The CPU module is the heart of the system Its backup power supply and two processors secure the MX 62 management Plug in the LED and LCD modules or remote connection via RS485 4 wires shield Centralized management Connection to different modules e Connection to an internal or externa
131. ppropriate mix with regulator spare replaceable cell alkaline battery pack Economy Confined Space Kits contain all of the essential equipment at an eco rugged Pelican case nomical cost including Choice of ITX monitor instrument carrying case con stant flow hand pump 10 feet of tubing replacement sampling pump filters compact charger rechargeable battery versions calibration cup with tubing training video durable carrying case Add 7 to part number for 230 VAC charger price is the same DELUXE CONFINED SPACE KITS M40 AND 40 CONFINED SPACE KITS PART DESCRIPTION M40 KIT 11111 M40 Kit LEL CO 5 PART DESCRIPTION M40 KIT 11101 M40 Kit LEL CO ITX Kit P11014 Professional iTX LEL H2S CO Li ion 120V M40 KIT 11110 M40 Kit LEL H2S ITX Kit D11014 Deluxe iTX LEL HS CO Li ion 120V MAOMKIT 11111 M40 m Kit CH4 CO 5 ITX Kit D11100 Deluxe CO Li ion 120V M40MKIT 11110 M40 m Kit CH4 5 ITX Kit D11400 Deluxe H S Li ion 120V M40MKIT 11101 M40 m Kit O2 CH4 ITX Kit D11000 Deluxe iTX LEL Li ion 120V M40MKIT 11100 M40 m Kit CH Deluxe Confined Space Kits come in a variety of options and include Choice of O TX monitor instrument carrying case motorized sampling pump ITX 10 ft M40 M40 m Confined Space Kits Include Choice of M40 or 40 o
132. ptional sensor and equipment combinations The matrix below can assist in determining the proper part number for the combination that best suits your needs For example An ITX with an sensor LEL sensor CO sensor H2S sensor with a lithium ion battery would have the following part number 18104307 11014 ORDERING INFORMATION a o Bo o p o p To oe Y O fom Nme lune rm pe fom rm Akane fot 3 3 Mm eB Hs 488 Fen p s 5 8 5 8 fem M 2 aire pre r amp fre eMe Me 3 MN arme faa A 00 5 Aline crt B8 Nw femme tre t Nm me fom fom femme em ER 60 5 Note Use sensors in the gray section only for three five and six gas configurations or for special application sensors Recommend Li ion battery option MOST COMMON INSTRUMENT CONFIGURATIONS OPTIONAL ACCESSORIES Equipped with Li ion battery to order with Alkaline batteries add an A as suffix PART DESCRIPTION PART DESCRIPTION 18105551 ABC DS2 Instrument Docking Station for iTX 18104307 11014 ITX LEL CO 5 Li ion 18104315 Single Unit Compact Charger Universal 18104307 11100 LEL O2 CO Li ion 18105296 Single Unit Compact Charger 12 VDC 18104307 11400 ITX LEL O2 H2S Li ion 18104737 120 Charger w Dat
133. r CGA 660 17059189 Calibration Cup T82 T80 not included w instrument 18106708 Demand Flow Regulator CGA 705 17128489 Calibration Cup MX6 iBrid 18102260 9 5521 Regulator 1 2 L min flow CGA 590 iai aac iL 17092339 Calibration Cup iTX 18100883 58 1031 Regulator 34L Aluminum Cylinders 1 2 L min flow L 17108622 Calibration Cup M40 18103580 9 58 1031 Bump Test Regulator w Trigger 17124033 Calibration Cup GasBadge Plus Pro 18103374 6501 Regulator 1 2L min flow CGA 330 17056326 Bump Cylinder Adapter for CO Breath Sampler 18104695 Regulator w Bump Test Trigger CGA 330 17054578 Calibration Coupling for MDU420 CDU440 18104356 Regulator w Bump Test Trigger CGA 590 17037961 Carrying Case for 2 Cylinders 58 103 1 18105924 5 port Clamp on Gas Manifold 18100149 Carrying Case for 2 Cylinders 34 L w 0 5 LPM Regulator 18105841 58 103 34L Demand Flow Regulator w iGas Pressure Switch 18105866 341 Demand Flow Regulator 600 CGA w iGas Pressure Switch MERE 18105833 5521 Demand Flow Regulator 590 CGA w iGas Pressure Switch VER eine doo ool UO 18105858 6501 Demand Flow Regulator 330 CGA w iGas Pressure Switch 17113283 Cylinder Recycling Tool 34L 18106740 Demand Flow Regulator 660 CGA w iGas Pressure Switch 18106757 Demand Flow Regulator 705 CGA w iGas Pressure Switch 18101776 58 1031 Regulator 1 L min flow e 58 103 L Regulator 1 2 L min flow Calibration Gas Cross Referenc
134. rgeable Lithium ion Battery Pack sing additional charging accessories from Industrial Scientific instrument operation can continue uninter rupted When a battery becomes low simply replace it with a spare pack and continue monitoring Or utilize a charging adapter to charge a 300 or 400 Series battery pack with a compact charger h Spare Battery Pack for the 300 amp 400 Series Ni Cad i Battery Charging Adapter for the 300 amp 400 Series Spare Battery Pack for the 300 amp 400 Series Disposable 9 volt Alkaline I Flying Lead Adapter for Dual Rate Chargers Spare Battery Pack for the 300 amp 400 Series Disposable Lithium Cells Batteries and Charging Accessories MX6 iBRID CHARGERS AND BATTERIES M40 CHARGERS PART DESCRIPTION 18106971 a MX6 Battery Charger supplied w MX6 18107094 c MX6 Battery Charger Datalink universal Software included 18107011 MX6 Battery Charger 12V 18107136 b MX6 Battery Charger 5 Unit shown w MX6 Unit not included 18107243 MX6 Truck Mount Charger 18107250 MX6 Truck Mount Charger hard wired 17131038 1 Li ion Battery Pack UL CSA ATEX MX6 iBrid 17131038 2 Li ion Ext Battery Pack UL CSA ATEX MX6 iBrid 17131038 4 Li ion Battery Pack MSHA AUS MX6 iBrid 17131038 5 Li ion Ext Battery Pack MSHA AUS MX6 iBrid 17131046 3 Alkaline Battery Pack UL CSA ATEX MX6 iBrid 17131046 6 Alkaline Battery Pack MSHA
135. ries are tightly sealed to avoid contamination from dust and liquid splashes The pre calibrated sensors of the OLCT 50 and OLCT 50D can be disconnected by simply turning the head of the unit The smart sensors can be calibrated outside hazardous areas Flameproof detector and transmitter ATEX EEx d T6 Ingress Protection IP66 Equipment Group and Category 11 2 GD EMC EN50270 Intrinsically safe transmitter ATEX II EEx 4 Ingress Protection IP66 Equipment Group and Category 11 1 GD EMC EN50270 OLC T 20 Fixed Monitor OLC T 20 HOUSING Stainless steel type 316 L ENCLOSURE Stainless steel epoxy polyester paint DETECTION PRINCIPLES Catalytic Electrochemical MEASURING RANGES Oxygen 0 to 30 by volume Carbon Monoxide 0 to 100 0 to 300 and 0 to 1 000 ppm Hydrogen Sulfide 0 to 30 0 100 0 1 000 ppm Nitric Oxide 0 to 100 0 to 300 and 1 000 ppm Nitrogen Dioxide 0 to 10 and 0 to 30 ppm Sulfur Dioxide 0 to 10 0 to 30 and 0 to 100 ppm Chlorine 0 to 10 ppm Hydrogen 0 to 2 000 ppm Hydrogen Chloride 0 to 30 and 0 to 100 ppm Hydrogen Cyanide 0 to 10 and 0 to 30 ppm Ammonia 0 to 100 and 0 to 1 000 ppm Ozone 0 to 1 ppm Phosphine 0 to 1 ppm Chlorine Dioxide 0 to 3 ppm Silane 0 to 50 ppm Arsine 0 to 1 ppm Methane catharometer 0 to 100 by volume Hydrogen catharometer O to 10096 by volume Ammonia catalytic
136. rogen Nitric Oxide 0 to 1 000 ppm in 1 ppm increments Chlorine 0 to 100 ppm in 0 1 ppm increments Nitrogen Dioxide Sulfur Dioxide 0 to 100 ppm in 0 1 ppm increments Hydrogen Cyanide Hydrogen Chloride 0 to 30 ppm in 0 1 ppm increments Ammonia 0 to 100 ppm in 1 ppm increments Chlorine Dioxide 0 to 1 ppm in 0 01 ppm increments Phosphine 0 to 5 ppm in 0 01 ppm increments 0 to 1 000 ppm in 1 ppm increments optional Carbon Dioxide 0 to 5 of volume in 0 0196 increments VOCs general 0 to 2 000 ppm in 0 1 increments POWER SOURCE RUN TIMES Rechargeable Lithium ion Li ion Battery Pack 24 hours typical Rechargeable Extended Range Lithium ion Li ion Battery Pack 36 hours typical Replaceable AA Alkaline Battery Pack 10 5 hours typical TEMPERATURE RANGE 20 C to 55 49F to 131 F typical HUMIDITY RANGE 1596 to 9596 non condensing continuous typical he MX6 iBrid is the world s first gas monitor to feature a full color LCD display screen The display improves safety with clear readings in low light bright light or anywhere in between Whether the work is outside inside or underground it s easy to see hazardous levels of oxygen toxic and combustible gas and volatile organic compounds VOCs in the immediate work environment A color display also allows the user to step through instrument settings and functions with an intuitive menu and the instrument s five way navigation button
137. rt black Replacement Sensors SENSOR REFERENCE CHART CHLORINE NITROGEN NITRIC HYDROGEN HYDROGEN CARBON CARBON HYDROGEN SULFUR METHANE MONOXIDE SULFIDE DIOXIDE NULL S0j INSTRUMENT OXYGEN 02 17100934 MX6 iBrid 17124975 3 17124975 K 17124975 1 17124975 G 17124975 2 17124975 5 17124975 7 17124975 8 17124975 6 17124975 4 17124975 D 17124975 B 17124975 A 17124975 9 Pentane 17100926 6313800 6313804 i a 17071234 17071408 25 6313780 6313969 6313787 6313841 412 17023516 17041856 17074204 TX418 17050129 N A 17071143 17067547 17071176 17071218 17071226 17074931 17071085 17070046 17066390 17041880 17041898 17041906 17073271 17041922 17049904 M40 17117730 a _ i 17067547 17074204 17041856 17067547 17074204 Lom _ 171 17124983 8 17124983 6 17071085 17041922 17049904 17077470 17077397 17071085 17041922 17049904 17077470 17077397 LTX312 17023516 LTX311 17023516 LTX310 17023516 CMX271 17035114 HMX271 17035114 MX251 17035114 GasBadge 17124983 3 Pro 82 17093766 80 17060484 5 70 17049940 200 Series 17011925 17070962 17040064 17022062 17030792 17038787 instrument 0X231 CD211 CO262 5267 60261 NO268 M
138. rt Ethernet Hub 18105932 6 Port Gas Regulator Manifold 17113960 24 Port Ethernet Hub IBrid Monitor Ac DOCKING STATION NGI 24 sensor options including PID and IR Diffusion mode or internal sampling pump versions Simple user friendly menu driven navigation Up to 6 gases monitored simultaneously Full color graphic LCD is highly visible in a variety of lighting conditions Internal sampling pump version SPECIFICATIONS CASE Lexan ABS Stainless Steel w protective rubber overmold DIMENSIONS 13 5 cm x 7 7 cm x 4 3 cm 5 3 x 3 05 x 1 7 diffusion version WEIGHT 409 g 14 4 oz DISPLAY READOUT STN Color Graphic LCD SENSORS Combustible Gas Methane Catalytic Diffusion Infrared Oxygen and Toxic Gases Electrochemical CO Infrared VOCs 10 6 eV Photolonization MEASURING RANGES Combustible Gases 0 to 100 LEL in 196 or 10 ppm increments Catalytic 0 to 10096 LEL in 1 increments optional Infrared Methane 0 to 5 of volume in 0 196 increments Catalytic 0 to 10096 of volume in 1 increments optional Infrared Oxygen 0 to 3096 of volume in 0 196 increments Carbon Monoxide 0 to 1 000 ppm in 1 ppm increments 0 to 9 999 ppm in 1 ppm increments optional Hydrogen Sulfide 0 to 500 ppm in 0 1 ppm increments CO H5S Carbon Monoxide 0 to 500 ppm in 1 ppm increments Hydrogen Sulfide 0 to 200 ppm in 0 1 ppm increments Hyd
139. s call your local representative or e mail info indsci com INDUSTRIAL SCIENTIFIC CARRYING CASES PART DESCRIPTION 18106856 0 Leather Carrying Case Diffusion MX6 iBrid 18106856 1 Hard Leather Case Diffusion no display window MX6 iBrid 18106880 0 Hard Leather Carrying Case Aspirated MX6 iBrid 18106880 0 Hard Leather Case Aspirated no display window 6 iBrid 18104703 c Leather Carrying Case iTX 18106369 Leather Carrying Case Heavy Duty w Window iTX 18106567 Leather Carrying Case Heavy Duty w o Window iTX 18103259 Leather Carrying Case ATX Series 18103267 Leather Carrying Case ATX Series MSHA Required 18102921 ATX Series Carrying Handle for 18103259 18103267 18101824 Leather Carrying Case 400 Series supplied w TMX412 TX418 18102798 Leather Carrying Case T82 T80 18102161 Leather Carrying Case Combination Instrument SP402 18102201 Leather Carrying Case 300 Series supplied w 312 311 310 18102308 Leather Carrying Case MDU420 CDU440 18103192 Leather Carrying Case MDU420 CDU440 MSHA Approved 18105981 Soft Sided Carrying Case M40 supplied with M40 18105999 Leather Carrying Case Combination M40 SP40 supplied w Inst Pump Combos 18106575 Leather Carrying Case Heavy Duty w Window M40 M40 M 18106559 Leather Carrying Case Heavy Duty w o Window M40 M40 M 18100628 Detachable Shoulder Strap for Leather Cases 17090572 Rubber Protective Boot 500 17094905 R
140. s Base part number 7814783 ABCDEFG sensor options as listed below Ordering example A Stand Alone iTrans with on board LEL 4 20 mA scale 0 100 and remote mount H2S 4 20 mA scale 0 999 with supply would have a part number of 7814783 1C21240 Stand Alone iTRans PART NUMBER ORDERING MATRIX A SENSOR 1 CONFIGURATION E SENSOR 2 CONFIGURATION 1 On Board 0 No Sensor 2 Remote max distance 200m 1 On Board 3 Non Hazardous Remote Duct Mount 2 Remote max distance 200m 4 On Board With Splash Guard 3 Non Hazardous Remote Duct Mount 5 Remote With Splash Guard 4 On Board With Splash Guard max distance 200m 5 Remote With Splash Guard max distance 200m B GAS SENSOR 1 1 Carbon Monoxide CO F GAS SENSOR 2 2 Nitric Oxide NO 1 Carbon Monoxide CO 3 Ammonia 2 Nitric Oxide NO 4 Hydrogen Sulfide H2S 3 Ammonia NH3 5 Sulfur Dioxide SO 4 Hydrogen Sulfide H2S 6 Nitrogen Dioxide NO 5 Sulfur Dioxide SO 7 Chlorine Cl 6 Nitrogen Dioxide NO 8 Chlorine Dioxide CIO 7 Chlorine 9 Hydrogen Cyanide HCN 8 Chlorine Dioxide CIO A Oxygen 03 9 Hydrogen Cyanide HCN B LEL Infrared factory methane calibration A Oxygen 03 C LEL Catalytic Plug In factory pentane calibration B LEL Infrared factory methane calibration D Carbon Monoxide Hydrogen Null CO H C LEL Catalytic Plug In factory pentane calibration F Hydroge
141. s and because it uses thousands of different signal patterns it ensures virtually interference free digital reliability OPTIONS LIGHTING ARRESTOR Surge IEC 1000 4 5 8 20us waveform 500 Joules Turn on 600 VDC120 2 5ns for 2kV ns 1 200 120 7ns for 2kV ns Vibration 1G up to 100 Hz Throughput energy 220uJ N Male bulkhead connector Frequency range 125 MHz to 1 000 MHz Maximum power 300 MHz to 1 GHz up to 50 W SOLAR POWER BATTERY BACKUP SYSTEMS 100 Watt System w Single Battery 1 2 sensors one remote alarm 3 b days battery backup 80 Watt System w Dual Batteries 2 3 sensors one remote alarm 3 b days battery backup 80 Watt System w Single Battery 1 2 sensors one remote alarm 3 b days battery backup 40 Watt System w Single Battery 1 sensor one remote alarm 3 5 days battery backup Solar systems include solar panels battery enclosure with charging circuit battery batteries and pipe mounting brackets Steel pile sensors and or remote alarm not included WIT Systems are application driven For further details about how a WIT System can best serve you please contact Industrial Scientific Corporation at 1 412 788 4353 An applications engineer is available to assist you with the completion of an application survey PERIMETER MONITORING OPTIONS 1 Ex I em Vli ES s i Permanent Pole Mount Mobile Push Cart System Fixed Systems Accessories
142. s are heavier than air Acetylene Ammonia Argon Butane Carbon Monoxide Ethylene Carbon Dioxide Chlorine Hydrogen Hydrogen Cyanide Ethane Hexane Methane Hydrogen Chloride Hydrogen Sulfide Methyl Ethyl Ketone Methyl Mercaptan Nitrogen Dioxide Nitrous Oxide Oxygen Phosphine Sulfur Dioxide Propane INTRINSIC SAFETY What is intrinsic safety Intrinsic safety is a design technique applied to electrical equipment and wiring for hazardous locations The technique is based on limiting energy electrical and thermal to a level below that required to ignite a specific hazardous atmospheric mixture How is intrinsic safety defined S Intrinsically safe equipment and wiring shall not be capable lt of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a flammable or combustible atmospheric mixture in its most easily ignitable concentration Equipment is tested and certified for intrinsic safety by indepen dent third party agencies such as Underwriters Laboratories SOURCE OF IGNITION UL Canadian Standards Association CSA Factory Mutual Research Corporation FM and the Mine Safety and Health Administration MSHA Independent testing ensures that your gas monitoring equipment is not only designed to be intrinsically safe but meets all required standards for intrinsic Ref Stahl Intrinsic Safety Primer 01988 National Electrical Code Article 504 2 D
143. s practical information to educate firefighters on the haz ards of gases in their profession T3 Train the Trainer Course This course was designed to train those responsible for training others in their organizations on gas monitoring issues This course includes information on gas hazards terms and technology and instrument operation On Site Custom Course Contact one of our expert trainers to discuss your specif ic training and curriculum objectives We will meet these objectives with a custom designed program held at the location of your choice With an On Site Custom Course you are in total control of the course content The cur riculum will be delivered to your specifications and com petency will be measured according to your standards Training and Support Tools PROFESSIONAL ONLINE TRAINING COURSES Industrial Scientific s professional online training courses capture the classroom training experience in an online format The courses combine video clips voiceover narra tion and recommended reading assignments divided into convenient modules that are accessible 24 hours day seven days week The format allows students to learn on their own time at their own pace Plus being able to go back and review any course topic can help students achieve a more complete understanding of the subject matter Instrument Operation Courses Courses in instrument operation are available for the MX6 iBrid iTX GasB
144. simple as possible Everything you ll need to test the atmosphere prior to entering a confined space is included in one durable easy to transport carrying case Your monitor choice determines the additional accessories that are included in the kit as some monitors are built with internal sampling pumps In addition to providing the gas monitoring equipment for confined space entry Industrial Scientific offers training classes and educational tools for large or small groups MX6 iBrid Confined Space Kit MX6 iBRID CONFINED SPACE KITS ECONOMY CONFINED SPACE KITS PART DESCRIPTION PART DESCRIPTION MX6KIT K1230211 6 Kit LEL H2S CO Ext Li ion Pump ITX Kit E11014 Economy iTX LEL H S CO Li ion 120V MX6KIT K 123R211 6 Kit LEL O2 H2S CO PID Ext Li ion Pump ITX Kit E11F00 Economy iTX LEL O2 5 Li ion 120V MX6KIT 0000R211 MX6 Kit PID Ext Li ion Pump i TX Kit E11100 Economy iTX LEL CO Li ion 120V 6 iBrid Confined Space Kits Include Choice of MX6 monitor universal ITX Kit E11400 Economy iTX LEL H2S Li ion 120V charger nylon carrying case belt clip calibration cup wrist strap maintenance tool manual quick start guide calibration tubing dust filter water stop aspi i TX Kit E11000 Economy iTX LEL Li ion 120V rated calibration fitting aspirated sample tubing aspirated calibration gas o a
145. software Calibration gas replenishment All repair parts labor and freight Not applicable for iNet Parts Program Setup Services e Installation setup and testing of Docking Stations server and instruments raining Travel expenses Continuous Monitoring Industrial Scientific continuously checks your instrument fleet via the Internet Data Services Asset tracking by serial number Secure off site data storage Data analysis E mail reports and alerts iNet Pricing A 48 month agreement locks in your pricing with no additional or hidden costs Should your needs change you can always update the agreement by adding instru ments to your fleet See the special section in the front of this catalogue for more information about iNet 4 4 SOLUTIONS FIXED SYSTEMS TURNKEY SERVICES Worry free industrial and commercial installations for fixed point monitoring Docking Station set up and software installation Solar powered installations Wireless installations Employee Instruction Custom on site evaluation Calibration amp maintenance programs available N ow the same company that manufactured your quality gas detection equipment can provide installation services too Industrial Scientific Start Up and Commissioning Services can have your gas detection program up and running quickly while eliminating the need for you to reassign employees or search for specialized technicia
146. sting the GasBadge Plus Monitor has never been easier or more cost effective The Cal Plus m features simple two button operation allowing the user SPECIFICATIONS to quickly and easily calibrate or function bump test the instrument The large LCD display and LED indicators MONITOR SUPPORTED then show whether or not the instrument passed or failed GasBadge Plus all versions the desired function 4 The Cal Plus is also available with a built in dot matrix Single Unit with Internal Printer printer that automatically prints calibration and bump test DIMENSIONS Single Unit reports to provide permanent documentation of instru 7 6 cm x 23 6 cm x 19 3 cm 3 x 9 3 x 7 67 ment serial numbers pass fail indications bump test DIMENSIONS Single Unit with Printer readings and full span readings for the GasBadge Plus 7 6 cm x 37 cm x 19 3 cm 3 x 14 55 x 7 6 PC is not required to operate this stand alone GAS INLETS EE system making the unit extremely portable and flexible PUMP FLOW RATE For space saving alternative the unit can be mounted 0 25 LPM to wall along with an optional calibration gas cylinder INPUT holder When used with PC alarm events instrument Universal AC power supply 110 240 VAC COMMUNICATION On board LEDs give status indication pass fail Multilingual LCD dis details and calibration and bump test reports are auto matically downloaded via a standard USB
147. struments are Guaranteed For Life Industrial Scientific offers factory repair service at our U S headquarters as well as all worldwide office loca tions Each factory service center offers fast turnaround and excellent value on any instrument repair and ensures that your instruments are repaired exactly to your speci fication The latest instrument software upgrades are also provided at no cost Call your local Industrial Scientific Office for factory service and support or go to www indsci com to download a factory repair form Industrial Scientific Mobile Service Technicians are capa ble of performing all levels of calibration maintenance and repairs on your equipment on site at your facility With this program instrument downtime 15 practically eliminated and there is no need to stock consumables or other replacement parts And all required maintenance documentation and record keeping is completed for you after each visit MAINTENANCE SOLUTIONS ndustrial Scientific products are manufactured to pro vide unparalleled reliability and designed to be simple for the user to maintain For customers with limited time personnel or resources several maintenance and repair programs are available to ensure your equipment is con sistently maintained to factory standards and in optimum working condition The DS2 Docking Station provides automated cali bration record keeping and diagnostics to help you properly maintain y
148. t maintenance and repair If a malfunction Is detected all necessary components are automatically shipped within 24 hours next business day iNet On Site Program Regular visits with an authorized Industrial Scientific service technician can be scheduled or automatically initiated in response to service requirements The iNet On Site Program is available in selected areas only LOOK FOR THIS SYMBOL ON ALL COMPATIBLE INSTRUMENT PAGES LIFETIME WARRANTY PROGRAM ndustrial Scientific designs and manufactures the highest quality instruments for the preservation of life and property Our warranty statement GUARANTEED FOR LIFE is not just an empty promise if anything fails on any of our portable gas monitoring instruments we pledge to promptly replace or repair it at no charge to you This warranty lasts for the life of the instrument and applies to almost all of our portable gas monitors Every component is covered except for routine consumable items sensors battery packs pump and filters which come with a one year warranty Of course physical damage or abuse such as crushing or drowning the instrument is not covered Accessories such as sam pling pumps probes and chargers also come with a one year warranty Instruments manufactured since January 1996 are considered under warranty Even if you sell your instru ment the warranty automatically transfers to the new owner In the event of a fail
149. t to change without notice R Fixed Monitor Combustible or gas monitor Long life infrared IR sensor Resistant to sensor poisons and corrosion 4 20 mA output Onshore and offshore applications Minimal maintenance OLCT IR SPECIFICATIONS HOUSING Stainless steel 316L DETECTION PRINCIPLE Optics Infrared absorption GASES DETECTED Hydrocarbons methane propane butane as standard CO Others on request MEASURING RANGE Combustible gases 0 to 100 LEL Methane 0 to 100 by volume Carbon Dioxide 0 to 3 by volume INGRESS PROTECTION IP66 OUTPUT SIGNAL 4 20 mA POWER SUPPLY 15 to 30 VDC at detector terminals POWER CONSUMPTION 2 5 W maximum OPERATING TEMPERATURE 25 to 55 50 to 55 for low temperature version IECEX ATEX Ex d e ia IIC T4 T135 C T amb 50 C to 65 C Ingress Protection IP66 Equipment Group and Category 11 2 GD EMC EN50270 SIL Approval SIL2 capability according to EN 50402 EN61508 ffshore platforms petrochemical and chemical industries naval installations waste water treat ment plants in these types of environments infrared technology is very often the only solution The OLCT IR Is built to withstand these harsh environments which require the most efficient gas detection The OLCT IR includes a case fitted with a mounting system and a wiring compartment for electrical connections in explosive
150. tch PART DESCRIPTION 18102260 18103374 18103549 18103556 18105833 18105858 18106740 VOL NOTES 18108019 CYL 250 ppm CO 25 ppm 5 19 O 50 LEL Methane 650 w CGA 330 fitting CYL 100 ppm CO 25 ppm HS 19 Oz 25 LEL Pentane MI OU CYL 100 ppm CO 25 ppm H S 19 Oz 2 Methane 16500 w CGA 330 fitting CYL 100 ppm CO 25 ppm HS 19 O2 2 5 Methane J J J 6506 w CGA 330 fitting CYL 100 ppm CO 5 ppm NO 19 2 5 Methane J J 650 w CGA 330 fitting CYL 100 ppm CO 25 ppm HS 19 02 25 LEL Propane 1 650 w CGA 330 fitting CYL 25 ppm HS 19 25 LEL Pentane O pg o 16501 w CGA 330 fitting CYL 100 ppm CO 19 25 LEL Pentane 22217 5521 w CGA 590 fitting 18102259 CYL 100 ppm CO 19 2 5 Methane Ed Ld Ll qd o 52 CYL 250 ppm CO 19 Or 25 Methane L p p 5521 w CGA 590 fitting CYL 100 ppm 2 5 19 25 LEL Pentane ET 892L w CGA 590 fitting 18106963 10 ppm Hydrogen Chloride ETL 18106633 CYL 25 ppm Hydrogen Sulfide 680 w CGA 330 fitting 18103101 CYL 100 ppmCarbonMonoxide f B82L W CGA 590 fitting 18104125 CYL 250 ppm CarbonMonoxide f f 5520 w CGA 590 fitting 18106955 CYL ppmChlorine 650 w CGA 330 fiting 18102320 CYL Zero Grade Air 2 9 1 100 552 w CGA 590 fitting ss jo
151. ted MX6 M1030401 MX6 CH 96 CO Li ion MSHA AUS DS2 Docking Station Ordering Information Mining A Wireless Option currently unavailable 0 none M SAS sw AAA B Gas Reader number included 0 No iGas Readers MX6 M1D34401 6 CH 96 CO NO Li ion Ext 1 1 iGas Reader MSHA AUS Mining Diesel Applications 2 2 iGas Readers 3 3 iGas Readers C Power Cord Option 0 US 1 UK 2 EU 3 AUS 4 ITA 5 DEN 6 SWZ Quad multi Gas Monitor DOCKING STATION iNet CASE MATERIAL Polycarbonate w protective rubber overmold DIMENSIONS 103 mm x 58 mm x 30 mm 4 1 x 2 3 x 1 2 with Li ion Battery Pack WEIGHT Lithium ion Battery version 180 g 6 4 Oz Alkaline Battery version 193 g 6 8 oz OPERATING TEMPERATURE RANGE 20 C to 50 4 F to 122 F typical OPERATING HUMIDITY RANGE 1596 9595 non condensing continuous typical DISPLAY READOUT Backlit Liquid Crystal Display LCD POWER SOURCE RUN TIME Li ion 12 hours typical 20 C Alkaline AAA 8 hours typical 20 ALARMS Ultra bright LEDs loud audible alarm 95 dB at 30 cm and vibrating alarm SENSORS Combustible gases methane Catalytic Diffusion CO H2S NO Electrochemical MEASURING RANGES Combustible Gases 0 100 LEL in 196 increments Methane CH4 0 596 of vol in 0 01 increments Oxygen 02 0 30 vol in 0 1 increments Carbon Monoxide CO 0 1 000 ppm in
152. to 113 F HUMIDITY RANGE Relative humidity 5 to 95 uncondensed COMPLIANCE European Standards 50054 50081 and 50082 IP RATING IP65 ORDERING INFORMATION PART DESCRIPTION W48I820 Wall Mounting Controller Type MX 48 fitted w 4 channels 8 channels max 230 VAC W480820 Wall Mounting Controller Type MX 48 fitted w 4 channels 8 channels max 230 VAC European Version W48I810 Wall Mounting Controller Type MX 48 fitted w 4 channels 8 channels max 110 VAC 6451452 Card of 4 Extra Channels for MX48 B103830 Wall Mount Battery Backup System Uninterrupted power supply 289 x 350 x 189 mm for MX48 Charger 24V 6A Batteries 17 Ah 1 16 Digital input channels 1 On board relay ModBus master and slave device Easy interface to SCADA HMI and PLCs e d 1600 Controller he 1600 Controller will automatically recognize and configure channels based on the number of sensors attached to the unit simplifying installation time and costs A single on board relay can be used to activate an external alarm device when alarm levels are reached SPECIFICATIONS ENCLOSURE Fiberglass NEMA 4X weather resistant lockable or Flush mount DIMENSIONS 35 6 cm x 30 5 cm x 16 5 cm 14 x 12 x 6 5 NEMA 24 8 cm x 18 3 cm x 6 35 cm 9 75 x 7 22 x 2 5 flush mount WEIGHT Approximately 0 9 kg 2 Ibs NUMBER OF INPUTS 16 ModBus RTU inputs SENSOR EXCITATION VOLTAG
153. trends and direct Calibration progress and results access to features readings graphically shown for each sensor ORDERING INFORMATION Wy Ranges P ren o Ph 3 5 6 1 8 English NO PH High PID 5 Liion Ext Range MSHA AUS 5 ltalian CO H low interference CO High CO H2S 6 Alkaline MSHA AUS 6 Dutch Hydrocarbons IR 0 100 LEL Pentane LEL Methane ERN Portuguese CO IR IR 0 100 vol 0 5 Indonesian Note There are millions of possible MX6 configurations If your specific needs aren t among the common configurations below use our custom instrument builder at www indsci com IVIX6builder aspx to select the best configuration for your gas detection needs MOST COMMON INSTRUMENT CONFIGURATIONS OPTIONAL ACCESSORIES PART DESCRIPTION PART DESCRIPTION MX6 K1230101 MX6 LEL CO H5S O2 Li ion 18106724 ABC 052 Docking Station for MX6 6 0230101 MX6 LEL H2S Li ion 18106765 SP6 Motorized Sampling Pump Module MX6 K1030101 MX6 LEL CO Li ion 18107078 MX6 Constant Flow Hand Aspirated Pump 6 0030101 MX6 LEL Li ion 18107086 6 Datalink Assembly Software included MX6 K123R21 1 MX6 LEL CO H2S PID Ext Li ion Pump 18106971 6 Replacement Battery Charger MX6 K1235101 MX6 LEL CO H S SO Li ion 18107094 MX6 Battery Charger Datalink Universal MX6 K0235101 MX6 LEL H2S O5
154. ty features include zero and cal fault protection and access code security The microprocessor controlled transmitters can operate independently or in a multi point configuration transmitting a 4 20mA signal or ModBus RTU digital out put to any control device or PLC iTrans can also work in a stand alone mode with optional on board relays When gas concentrations exceed pre set limits the unit can activate alarms horns and fans or shut down systems without being wired back to a central control panel Stainless Steel Trans fixed Monitor iTrans Stainless Steel Monitors offers a wide variety of sensor configurations and relay options for maximum flexibility and affordability Use the following guide to select the options that best fit your monitoring needs and applications Industrial Scientific recommends that a fixed system application survey be completed to help provide the most accurate assessment of your equipment requirements iTrans Base Part Number 7814635 ABCDEFG sensor options as listed below Dual reading LED display magnetic calibration tool and calibration cup are standard items with all iTrans monitors Ordering example An iTrans with an on board LEL 4 20 mA scale 0 100 and remote mount HS 4 20 mA scale 0 500 with optional relays would have a part number of 7814635 6C21741 STAINLESS STEEL iTrans PART NUMBER ORDERING MATRIX A SENSOR 1 CONFIGURATION E SENSOR 2 CONFIGURATION 6 XP 316 Stainless Steel
155. ubber Protective Boot T82 T80 PART DESCRIPTION 18106831 Nylon Carrying Case MX6 supplied w MX6 diffusion 18106864 Nylon Carrying Case MX6 SP6 Aspirated supplied w MX6 18104661 Nylon Carrying Case i TX supplied w i TX 18104687 Nylon Carrying Case Combination iTX iSP 18104679 Nylon Carrying Case ATX Series 18104240 Nylon Carrying Case 400 Series 18104109 Nylon Carrying Case Combination Instrument SP402 18104042 Nylon Carrying Case 300 Series and MG140 supplied w MG140 18105478 Nylon Carrying Case M40 18105486 Nylon Carrying Case Combination M40 SP40 18106484 Nylon Carrying Case GasBadge Pro 18106492 Nylon Carrying Case 2 unit GasBadge Pro 18106401 Nylon Carrying Case GasBadge Plus 18106419 d Nylon Carrying Case 2 unit GasBadge Plus 18103978 Nylon Carrying Case T82 T80 18105874 Nylon Carrying Case T40 18105171 ATX Chest Harness 18103515 Disposable Vinyl HazMat ATX Case 18102335 Disposable Combination 300 400 Series Instrument Pump Case 18102229 Disposable Vinyl HazMat Belt Case 300 400 Series 18102177 Optional Handle for Combination Case Instrument SP402 18102192 WeatherGuard Case w o External Alarm i TX 300 400 Series 18102220 WeatherGuard Case w External Alarm i TX 300 400 Series 18104000 WeatherGuard Case w o External Alarm ATX Series 18104018 WeatherGuard Case w External Alarm ATX Series 17051487 High Impact Carry Case Dust Water Tight Pelican 18101840 Instrument and Accessory Case w Foam Inse
156. ulfide SENSOR Chlorine Hydrogen Hydrogen Phosphine Dioxide Cyanide Chloride Hydrogen Ammonia The table above reflects the percentage response provided by the sensor listed across the top of the chart when exposed to known concentration of the target gas listed in the left hand column Note This table is given as guide only and is subject to change No data available COMMON CHEMICAL NAMES AND SYMBOLS Ammonia Arsine Benzene Bromine Carbon Dioxide Carbon Monoxide Chlorine Chlorine Dioxide Ethylene Oxide Fluorine Hydrogen Hydrogen Bromide Hydrogen Chloride Hydrogen Cyanide NH3 AsH3 CeHe Bro CO CIO ETO F2 H2 HBr HCI HCN Hydrogen Fluoride Hydrogen Sulfide Methane Nitric Acid Nitric Oxide Nitrogen Nitrogen Dioxide Oxygen Ozone Phosgene Phosphine Silane Sulfur Dioxide Sulfuric Acid HF H2S HNO NO N2 PH SO H2S04 Reference Library HAZARDOUS GASES FOUND IN COMMON INDUSTRIAL ENVIRONMENTS All values listed are established by NIOSH unless otherwise noted Ammonia NH Colorless toxic gas with a pungent suffocating odor PEL TWA 25 0 ppm STEL 35 0 ppm IDLH 500 0 ppm LEL 15 0 of volume Fertilizer Plants e Water and Wastewater Treatment Plants Refrigeration Facilities and Cold Storage Semiconductor Industry Carbon Dioxide CO Colorless odorless gas PEL TWA 5 000 0 ppm
157. w 34L Zero Air 103235 ee 103 4718100859 581 1031 w 103L Zero Air L w 103L Zero Air sat E NENNEN NER 18107995 e O1 O1 01 01 34L 34L w CGA 600 fitting m 34L w CGA 600 fitting FIT IN e Co r Calibration Gas Cross Reference Chart 0 5LPM 0 5LPM Demand Flow Regulator Demand Flow Regulator w Regulator Regulator iGas Pressure Switch PART DESCRIPTION 18100883 18100933 18102509 18103564 18105841 18105866 VOL NOTES 18105767 CYL 5ppmButadiene 100 toe 18106146 CYL 300 ppm Carbon Dioxide o Oo 10 to 18106183 CV 1 000 ppm Carbon Dede EM Um CYL 25 Carbon Dioxide 1 12 9 m ee tcx 18103275 KIT w 34L Zero Air O S af fn enes ste E Oo oaf y 18100750 KIT W 34L Zero Air pg p1088 JP ML jas 18100743 KIT W 34L Zero Air 18102162 KIT 1098 o O un 18102302 CYL 250 ppm Carbon Monoxide fig o poo tose PO 18101063 CYL 300 ppm Carbon Monoxide o 8k wCGA 600 fitting 18102303 CYL 500ppmCarbonMonoxide C To o T9X3 18102806 CYL 2ppm Chlorine pg pp o 8 18103697 CYLSppmChlorime Pw 18105007 CYL 10ppmChiorine dg Jo 34 faluminum
158. wer is 12 24 VDC for the AirAware while a 110 220 VAC power supply option is available for convenient plug in monitoring applications Configure your AirAware to match your needs adding options such as on board audible alarm for maximum attention or a vanity plate to hide the display The AirAware is covered by a one year warranty AlrAware Single Gas Monitor AirAware has numerous sensor and equipment configurations that allow you to customize the monitor to meet your specific needs The following matrix will help you to select the options within a single part number For example a part number of 68100056 11211 would be an AirAware Carbon Monoxide monitor with an on board audible alarm a 4 20mA output with no on board relay contacts an AC power adapter installed and a vanity faceplate cover AirAware PART NUMBER ORDERING MATRIX BASE PART NUMBER 68100056 ABCDE A GAS TYPE 1 Carbon Monoxide CO ArAware COMMON CONFIGURATIONS Chlorine Cl Nitric Oxide NO Ammonia NH3 2 3 4 Hydrogen Sulfide H2S 5 Sulfur Dioxide SO gt 6 Nitrogen Dioxide NO p Chlorine Dioxide Hydrogen Cyanide HCN Oxygen 0j Hydrogen Chloride Phosphine PART 68100056 11010 68100056 11100 68100056 11300 CO Control Transmit w Audio Alarm DESCRIPTION CO Monitor w Power Supply Audio Alarm CO Control w Audio Alarm B ON
159. x 16 3 cm x 22 9 cm 9 75 x 6 4 x 9 INPUT 115 230 VAC 50 60 Hz 12 VDC OPERATING TEMPERATURE 0 to 50 C 32 F to 122 F COMMUNICATION 10bT Ethernet support RJ 45 Category 5 connection DISPLAY 128 x 64 Dot Matrix LCD Multilingual modes allow selections in English Spanish French and German languages PUMP FLOW RATE 500 ml minute 80 H20 GAS INPUTS 3 separate inputs on each IDS Ability to share up to 14 discrete gases for calibration when IDSs are clustered together DS2 COMPUTER REQUIREMENTS MINIMUM RECOMMENDED For 1 8 IDS units Dedicated Pentium 800 MHz 256 MB RAM AGB available disk space Windows 2000 Professional Windows Professional operating system one CatbE Ethernet network adapter fixed IP address For 9 100 IDS units Dedicated Pentium Ill 800 MHz 256 MB RAM 4GB available disk space Windows 2000 Standard Server Windows 2003 Server operating system one CatbE Ethernet network adapter fixed IP address i 1 4 Y Fi n FEE EU i Pa SPECIFICATIONS Automates instrument calibration record keeping diagnostics and recharging Stand alone Instrument Docking Stations IDS Link up to 100 IDSs Dock hundreds of instruments Look FOR DOCKING STATION SYMBOL ON COMPATIBLE INsTRUMENT PAGES US Patent 76 442 639 International Patent 22WO0182063 he DS2 Docking Station provides the ultimate flex ibility for manag
160. y Service Centers offer fast turnaround and ensure that your instruments are repaired exactly to specification Only factory original parts are used to ensure the instrument s intrinsic safety is never compromised Mobile Service where available Industrial Scientific s Mobile Service Technicians can perform all levels of service from calibration to repairs on site at any facility within their service area Extended Warranty Program The Extended Warranty Program is designed to secure your cost of ownership for instruments with limited warranties non Guaranteed For Life equipment This additional coverage extends the warranty to a full four years and must be purchased within the first six months of instrument ownership For information on all of these programs e mail us at info indsci com or contact your local representative TABLE OF CONTENTS 1 N 4 5 6 PORTABLE INSTRUMENTS DS2 DockinG STATION MX6 IBrRiD Murri GAs Monitor MX4 1Quap Mutti GAs Monitor ITX Mutti Gas Monitor 25 TRANSPORTABLE Mutti Gas REA Monitor GASBADGE Pro SINGLE GAs Monitor GasBapcE Pius PERSONAL SINGLE GAS Monitor M40 Mutti Gas Monitor Me CaL CALIBRATION STATION CaL PLUS CALIBRATION STATION CONFINED SPACE KITS PORTABLE INSTRUMENT CCESSORIES REMOTE SAMPLING EQUIPMENT BATTERIES AND CHARGING ACCESSORIES INSTRUMENT CARRYING CASES REPLACEMENT SENSORS CALIBRATION EQUIPMENT CALIBRATION GAS CROSS
161. y automation and industry best practices WHAT iNET DOES Performs instrument bump tests calibrations and data downloads Analyzes instrument data dentifies service requirements PS Generates scheduled reports Sends immediate alerts nitiates repairs or replacement services HOW iNET WORKS Customer either receives new part s to install or a replacement instrument iNet sends status and warning reports to customer iNet analyzes data identifies service requirements WHAT iNET DOES FOR YOU Ensures Equipment Reliability With automated maintenance all of your gas detectors will be in top working condition The result is safer workplace and increased compliance Increases Compliance Reduces Risk Electronic and paper records prove compliance to external auditors Custom alerts and reports can also measure internal compliance to your own standards Increases Productivity Automating time consuming maintenance tasks increases productivity allowing more resources to be focused toward your company s core business Controls Costs Optimizes Fleet Size In addition to controlling labor costs iNet virtually eliminates instrument downtime With a fleet of well maintained and reliable equipment you won t have to buy and maintain a stock of replacements And because iNet is all inclusive excess purchasing shipping and inventory costs can also be eliminated
162. ything from exposure limits to the definition of intrinsic safety Remember anytime you have a question involving monitoring or safety simply call 1 412 788 4353 or visit our Web site at www indsci com Our customer service representatives helped us pull together a library of the questions we re asked most often Use this section as a quick reference when you have a question And if you don t find your answer here give us a call There s never a charge for a question GLOSSARY OF OCCUPATIONAL SAFETY AND HEALTH TERMS dB Decibel A unit used to measure the relative power of sound A 3 dB increase in sound output power represents a doubling of the perceptible volume eV Electron Volt A measurement of energy equal to the amount of energy it takes to move 1 electron through 1 volt of potential IDLH Immediately Dangerous to Life and Health The maximum concentration of gas in ppm from which a worker could escape within 30 minutes with out experiencing any escape impairing or irreversible health effects LEL LFL Lower Explosive Limit Lower Flammable Limit The minimum concentration at which a gas will explode A common unit of measurement is a percent of the LEL mA Milliamp A unit of electric current expressed in amperes 4 20 mA signals are commonly used analog signals in industrial electronics where 4 represents the lowest value for instance 0 ppm and 20 repre sents the maximum for instance 999 ppm
163. zones Using a magnetic system housed in this compartment the user can calibrate the detector locally in explosive zones by setting the zero and sensitivity without opening the compartment cover Proven Leading Edge Technology Zero Maintenance Efficiency semi conductor electronics of the OLCT IR guarantee extreme accuracy and constant stability Costs are considerably reduced Lifetime detector stability after initial calibration Requires minimal maintenance The answer to false alarms The economic implications of false alarms have led us to design the OLCT IR with the ability to ignore external elements that trigger false alarms Non intrusive calibration Equipped with a non intrusive system allowing a single operator to access a protected menu The detector can therefore be calibrated in an explosive area in total compliance with safety rules Unrivaled Performance Reliability Highly resistant to sensor poisoning High gas concentration does not saturate the transmitted signal All vital functions are maintained even if an accumulation of dust or other substances reduces transmission by 70 Heated mirror and window to prevent misting or icing of the optics Operates in an oxygen deficient atmosphere Durability Stainless steel explosion proof compartment secure connection compartment The mirror is made of quartz External optics are made of quartz capable of with standing high pressur
Download Pdf Manuals
Related Search
Related Contents
M3062PT-EPBM User`s Manual ( for replacement ) ACM-D1_D2 (Junior 300 / Power 500) Pulse Oximeter, Pulse Oximeters Smeg S47 Instructions for Use La reforme du regime des iobsp Assembly and operating instructions AKOvisc 取扱説明書 ① ② Samsung Galaxy Tab MPR500 Motor Protection Relay User`s Guide Westinghouse Digital Electronics DPF-1411 digital photo frame Copyright © All rights reserved.