1. available to drive load With external supply maximum voltage is 24Vdc 2 Available as options requires receive to be enabled 10 bit resolution 0 20mA 4 20mA 0 5Vdc 4 inputs standard 8 with DUAL SIT60 Contact Closure Internal Pull up Resistor Pulse Counters 1 input standard 3 optional 8 total with DUAL SIT60 Lightning and surge protection available on all inputs Transmit 150MHz Receive 138MHz 2400 Baud Anywhere with an unobstructed view of the sky 1 meter whip 16 foot cable standard longer as option 12Vde 5mA Standby 50mA Receiving Mode Enabled 2A Transmitting 12Vdc Battery standard Optional battery charger Optional 120Vac or 220Vac adaptor Optional solar charger 40 to 60 Celsius 40 to 140 Fahrenheit 100 Humidity Non condensing Global Water Instrumentation SIT60 Field Station Transmit LED Digital Inputs Battery Connector Power Up LED Test Button Analog Inputs Data port Clock Battery Station ID Battery Charger Control Outputs Rechargeable Battery Radio Interface Radio Module gt Satellite Antenna A El Indicator Connector Figure 2 SIT60 Field Station Global Water Instrumentation Description The basic SIT60 Field Station consists of a weatherproof case antenna with 16 cable mounting brackets radio module RTU control board satellite indicator 12volt battery T O interface connectors conf
2. system current to 5mA but the receiver is turned off in this mode so you will not be able to send control or interrogation commands to the Field Station or get real time time stamps In standby mode the processor must power up the radio receiver for one minute to allow communication with the satellite before reading the sensors and sending data The radio remains powered up 70mA 50mA until contact is made with the satellite A third option is available which is combination of both receive and standby modes The unit can is shipped in receive mode allowing interrogation controls and time stamp until a power down command is sent via email This power down mode is permanent and can only be undone by returning the system to Global Water The format for the command is as follows To lt radioname gt ORBCOMM NET Subject SLP YES Body lt empty gt Don t type anything in the body of the message Additional power is consumed by other factors The transmitter draws 2A when transmitting and the amount of time it spends communicating with the satellite is unpredictable More time is required when a satellite is temporarily out of range but in general you can assume it draws 2A for 15 seconds out of every transmission period The sensors draw power during the sensor warm up with a typical warm up time of 1 3 seconds every transmission Some sensors are on all the time which can be a significant factor in a low power system and should be evaluated on
3. 1 2 Control Output 100 0 J4 3 Figure 3 Sensor Offset Table Each SIT60 Field Station is assigned a StationID at the time of configuration Accessing the sensor information in the database requires knowing the SensorID which is the StationID plus an offset value The above example is for a SIT60 with StationID of 100 The data from all sensors is transmitted to the database as a block of raw data where the data for each individual sensor is manipulated by using the Adder and Multiplier values in the Sensor Configuration menu as described in the User s Manual Determining which part of the data block to use for a given sensor is done using the offset number There are 2 fields in the Sensor Configuration menu that accomplish this The StationID is the fixed value assigned to the Field Station itself and the SensorID indicates which channel Global Water Instrumentation is being used Ifa water level sensor is connected to analog input channel 1 a value of 100 is entered in the StationID field and 101 in the SensorID field as shown in the above table The corresponding raw data value for this sensor will then be used along with the Adder Multiplier Engineering Units etc to determine how the data is displayed and what alarm conditions if any exist Digital accumulators are each assigned a separate channel since the range of data is 0 2047 Digital status and status event are single bits so all 4 available inputs are grouped into one
4. Global Water Instrumentation SIT60 Hardware Manual Global Water Instrumentation Inc 11390 Amalgam Way Gold River CA 95670 T 800 876 1172 Int l 916 638 3429 F 916 638 3270 Globalw com globalw global com Global Water Instrumentation Table of Contents l Specifications e e o Page 3 Il SIT6O Field Station 4 ll Description o 5 IV Latency Time e 7 V Power Consumption e 7 VI Station ID Offset e 8 VII Time Stamps e o 9 Global Water Instrumentation Specifications Operating Modes Timed Mode Digital Event Mode Analog Event Mode Interrogation Control Output Input Configurations Analog Inputs Digital Inputs Options RF Frequency Rate Range Antenna Type Power Supply Voltage Supply Current Source Operating Conditions Sensor values and or output status are reported at user programmable time intervals 1 minute increments A report of any digital input is generated whenever it changes state Digital event inputs can be programmed as pulse counters accumulators A change in the reading of any analog input generates a report when it changes by more than a pre programmed percentage for early detection of rapidly changing conditions Sensor value or control status can be interrogated at any time by email requires receive mode to be enabled Control by email 0 1A current sink per output 12Vdc supply
5. Radio Module The data port is also used to connect the RTU board to a computer for configuring the transmit interval sensor warm up time analog and digital input modes output controls and analog alarm levels The interface uses a standard RS 232 format but requires a special cable and software not supplied with basic SIT60 system Configuration is done by Global Water at the time of assembly Contact Global Water if reconfiguration is required When data is transmitted power is applied to the sensors for a warm up period the sensors are read and then the data is sent The red Power UP LED is comes on during sensor warm up or when the processor detects a change of state on a digital status input The green Transmit LED is turned on as the control board communicates with the radio Data is transmitted when 1 of 4 conditions occur 1 Interrogation by email as described in the User s Manual will cause the input and output status to be sent on demand 2 Data is sent on a regular basis based on a preprogrammed time interval This interval is programmed at the time of assembly based on the customer s requirements in increments of 1 minute from 1 to 9999 3 Transmission can occur instantly when there is a change of state at one of the status event inputs or when an analog input level deviates from the last value by more than a preset percentage A digital input is programmed as an accumulator status or status event at the time of assembly O
6. a case by case basis Lastly the Satellite Indicator board has an LED that draws about 20mA when a satellite is within range which can be more than 75 of the time with good sky If power consumption is an issue the connector to the indicator board should be unplugged and tied down Global Water Instrumentation In remote locations a solar cell should be used unless the Field Station will be serviced often enough to keep a fully charged battery in place As a general rule of thumb the maximum capacity of the solar collector should exceed the average current drain of the system by 10 times Dust will settle on the surface of the solar array over time reducing its efficiency It should be kept clear of snow and cleaned often enough to keep the battery charged Station ID Offset Channel Type Example Station ID Offset Connector ID 100 Terminal Analog Inputs 1 Analog Input 101 1 J5 2 2 Analog Input 102 2 J5 5 3 Analog Input 103 3 J5 8 4 Analog Input 104 4 J5 11 Digital Inputs 1 Digital Status or Status Event 94 6 J6 2 2 Digital Status or Status Event 94 6 J6 5 3 Digital Status or Status Event 94 6 J6 8 4 Digital Status or Status Event 94 6 J6 11 OR 1 Momentary Accumulator 99 1 J6 2 2 Momentary Accumulator 97 3 J6 5 3 Momentary Accumulator 96 4 J6 8 4 Momentary Accumulator 95 5 J6 11 Control Outputs 1 Control Output 100 0 J4
7. and is used for transmission and receiving so a one meter whip antenna is suitable An unobstructed view of the sky is required the more unobstructed the view the more likely it is that a satellite will be within receiving range and the shorter the latency time will be Global Water Instrumentation Latency Time Latency time is the total time between the SIT60 sending data and the data appearing on the hosting web site The data is held in the radio module until one of 30 satellites is within range and then sent The information is further held at the satellite until its data buffers are full before relaying it to one of several ground stations where it is transferred to the Internet These two factors contribute most of the latency time but additional small time delays are added by data servers Total delay time is not predictable but areas with good satellite coverage and an unobstructed view of the sky can expect a total delay of 1 to 5 minutes Some international locations are not as well covered and may experience longer delays as can locations such as canyons mountainous areas and places surrounded by tall buildings Power Consumption There are two power configurations modes for the SIT60 Receive Mode allows the ability to remotely interrogate the system operate control outputs via email or receive real time time stamps The total supply current in this mode is about 70mA 50mA with Satellite Indicator unplugged Standby Mode drops the
8. iguration report hardware manual and user s manual Figure 1 and figure 2 show the location of the inputs outputs controls and indicators used to interface with the SIT60 Field Station Four Analog Inputs come standard and are capable of monitoring 0 20mA 4 20mA and 0 5volt sensors Three terminals are provided for each sensor Ground Signal and 12volts switched When the RTU begins to read the sensors it will apply power to the switched supply for predetermined length of sensor warm up time When this time has elapsed the reading will be taken and transmitted The Signal Input sources current to ground for the case of 4 20mA and 0 20mA sensors For 0 5volt sensors the input voltage is referenced to ground The sensor loop current is converted to a voltage by passing it through a 250ohm resistor yielding a full scale voltage of 5 volts at 20mA The resulting 0 5 volt 0 20mA signal is converted to 10bit digital data or a raw data value of 0 1023 The Digital Inputs can be configured as status inputs or as accumulators One input is standard and three additional inputs are available as options Digital inputs are contact closure to ground and have internal 19 6K pull up resistors to 12volts A status input is read as a single bit in a 4bit word Inputs 1 4 are associated with bits 1 4 respectively All inputs high gives a raw data reading of 15 bit 1 low reads 14 bit 4 low is 7 etc Individual bit status is checked by the database to as
9. is feature which increases the power consumption as previously discussed The time stamp also counts as 12 bits of data which can increase the data handling charge depending to configuration of the system
10. nly a status event will cause an instantaneous transmission The percentage of change in an analog input required to cause a transmission is also programmed at the time of configuration Since voltage is required for sensors they must be powered up This will happen at the normal transmission interval or at a second preprogrammed interval set in increments of minutes from 1 up to the normal transmission interval For example The system can transmit every hour but the sensors can be checked every 10 minutes to detect fast changing conditions 4 Data is transmitted when the Test Button is pressed and held for about 1 second This button when pressed will also reset the processor and turn the control outputs to OFF The Satellite Indicator has a red LED that comes on when a satellite is within receiving range It is not necessary for it to be on to make a transmission The radio module will hold the data and continue to poll the satellite until contact is made then transmit The radio module is connected to the antenna through the Antenna Connector using a standard SMA connector The SIT60 is supplied with 16 feet of cable but should more length be needed an extender cable can be added Extra cable can be ordered from Global Water or can be obtained from an outside vendor Standard SMA connectors and RG 58 cable are used for lengths up to about 30 feet Should longer cables be needed it is suggested that a cable with lower loss is used The VHF b
11. sign digital labels Accumulator data is sent as an 11bit number from 0 2047 The next increment after 2047 is zero The accumulator cannot be reset to zero without a firmware change by Global Water Accumulator totals such as rainfall can be kept track of using the totals table in FileAmigo Two Control Outputs are available as options for controlling a wide variety of devices The open drain output switches to ground when turned ON and can sink up to 100mA at 24 volts and can drive a de load directly or a relay for controlling heavier loads The outputs are controlled by email commands as described in the User s Manual Control commands should be sent one at a time Sending a second command before the Field Station has received the first may result in one of them being lost The SIT60 Field Station is given a Station ID and a Station Name by Global Water which are used as identifiers for remotely communicating with the station and accessing data at the website Both are provided on a configuration report furnished with the unit Power to the Field Station is 12VDC and is supplied to the RTU board through the Battery Connector using the supplied cable The unit is supplied with a 4A Rechargeable Battery Optional power sources such as trickle chargers solar cells and AC DC converters 2A minimum can be connected using the Battery Charger input Global Water Instrumentation The DATA Port connects the RTU Board to the Radio Interface on the
12. single channel where a single bit indicates the status of each input The difference between status and status event is that a status event causes a transmission at the time the input changes state where as a status input has its state transmitted at the normal time interval between transmissions The states of the control outputs are also single bits and so are grouped into a single channel In the case of status inputs status event inputs and control outputs the database uses the input channel number to determine the corresponding bit to be used for assigning digital labels in the Digital Labels menu Bit 1 for input channel 1 etc Time Stamps Two different time stamp modes are available to indicate when incoming data was taken both of which are given in Greenwich Mean Time GMT Normally when the data arrives at the web site it is given a time stamp which is equal to the time the data was taken plus the latency time involved in getting it to the database A second real time stamp is available which shows the actual time the data was taken The time is added to the data packet by the satellite when the sensors data is sent and applied to the database when the data arrives at the website Real time stamp mode is initiated by sending an email message of the following format To lt radioname gt QORBCOMM NET Subject TSS YES Body lt empty gt Don t type anything in the body of the message Receive Mode must be enabled to implement th
Download Pdf Manuals
Related Search
Related Contents
9号-2(PDF:313KB) Instructions for use Instrucciones de uso Manual de utilização Guide stagiaire 2014 2015 - Centre universitaire Jean Altova Authentic 2010 Browser Edition User Manual - Maxon Australia Troubleshooting Navionics Charts in Lowrance Handhelds Home Decorators Collection 1663110410 Instructions / Assembly Copyright © All rights reserved.