Home
SP 2000 USER MANUAL SpacePak Series Product Data
Contents
1. SP 2000 USER MANUAL SpacePak Series Photoelectric diffuse proximity EN sensors o eos Telco e SENSOYS Product Data Mounting amp Alignment Electrical Data Supply Voltage Voltage ripple Reverse polarity protected Short circuit protected Current consumption Output relay Output transistor Environmental Data DC AC 10 30 V dc 12 240 V dc 20 240 V ac 15 Yes Yes lt 65 mA lt 70 mA 1 open 1 close 240 Vac 3A 200 mA 30 V de Temperature operation 20 to 55 C Sealing class IP 67 ac G Approvals dc CE Available Models F Sensing Model Supply Voltage Output Time Delay Range SPP 2603 T On Off Delay SPP 2603 10 30 V de NPN PNP 7 0 3m SPP 2903 T 12 240 V de Rela On Off Delay adjustable Diffuse SPP 2903 20 240 V ac y 5 proximity SPP 2605 T 3 On Off Delay SPP 2605 10 30 V de NPN PNP F Su SPP 2905 T 12 240 V de Rela On Off Delay adjustable SPP 2905 20 240 V ac y Note Measured against matt white A4 paper Illustration Led Indicators ed O O Indicators Signal status red Z A Sensitivity adjustment O Output yellow r Pi O lt 4 DarkLight switch Power green V mm 5 Fi 4 On delay adjustment only T models i lt To 4 Off delay adjustment only T models Connection Wiring Diagrams Brown White Brown 1 O Whit
2. e 5 NC Black ty it Blue NC Do not connect wii m NC Black 4 nag Blue 3 pa e 2 re NC Do not connect wire SPP 2603 SPP 2605 SPP 2603 SPP 2605 Load as NPN Load as PNP Connection Wires Pins Supply Supply ac Supply Supply ac Output NC Output NO Output COM Output PNP Output NPN Made in Denmark Website www telcosensors com E Mail info telcosensors com This product is not a safety system and must not be used as such It is not designed for personnel safety applications and must not be used Brown y _ ____ nc White Hie goc Black H oy no Blue O a yh ht SPP 2903 SPP 2905 Relay output Cable 4 pin M12 plug Brown Pin 1 Brown Blue Pin 3 Blue Grey Black White Black Pin 4 Black White Pin 2 White Sensor plug Mounting amp Installation 1 Position the sensor pointing at the target object 2 Align by moving sensor horizontally and vertically until the output changes when the target object is present refer to Output Logic table 3 Fasten the sensor securely using the enclosed mounting bracket and hardware Avoid acute angles on cable close to sensor Adjustments Output Mode Selection The output mode can be selected via an integral light dark switch Refer to Output Logic table for output mode reference Enables the output to be active Turn switch to full clockwise Hant Opad gno when there is an object pr
3. esent position Enables the output to be inactive Turn switch to full counter Dark Operated N C when there is an object present clockwise position Output Logic Relay Transistor Output Detsen Ouiganit nests Output Output indicator Cejas Dark operated C ho No Open ott m gt A Light operated C Noj INC Closed On N O Object absent 7 Light operated C NO Nc N O T Open Off gt Dark operated c INO Nc N C Closed On Sensitivity Adjustment Proceed with the following steps Select target object with smallest dimensions and most translucent surface Place in correct position to the SPP ncrease sensitivity slowly from minimum full counter clockwise until the yellow 2 output indicator changes Increase a little further until the red Insufficient Signal indicator is off Remove target object If output changes the sensitivity is adjusted correctly If the output does not change then proceed to step 4 4 Place target object in correct position Decrease the sensitivity by turning the gain potentiometer counter clockwise until the red Insufficient Signal indicator is on Remove target object If the output changes the sensitivity is adjusted to suit the 5 target and target surroundings but the adjustment is very delicate and not advisable f the output does not change the target object is placed too close to surrounding 6 objects Attempt t
4. o change position or to angle the sensor in relation to the surrounding objects Then repeat procedure from step 1 Time Delay Adjustment T models The on delay enables output signal to only activate if an object in the detection area is present for the adjusted time period In Light operated mode The off delay enables output signal to remain activated for the adjusted time period The time delay is adjustable between 0 10 sec On delan Increase or decrease on delay by turning potentiometer clockwise or y counter clockwise respectively Increase or decrease off delay by turning potentiometer clockwise or Shiite counter clockwise respectively Warning V 1 11 Part Number 0666220633 February 2011 edition Telco A S reserves the right to make changes without prior notice as a stand alone personnel safety system
Download Pdf Manuals
Related Search
Related Contents
now Samsung Galaxy Note 8 LTE Uživatelská přiručka 取 扱 説 明 書 loyal Windsor For server control that gets to the point, choose this ServView with a BEDIENUNGSANLEITUNG Universal Remote Instruction Manual "user manual" ASUS VX7SX-DH72 User's Manual Copyright © All rights reserved.
Failed to retrieve file