System remote controller Misubishi Electric PAC

image

Contents

1. Remote controller main unit 8 1 Using with master system controller When connecting multiple system controllers the system controller with many functions is designated as the master and the system controller with few functions is designated as the slave The master slave functions of the system controller used together are as follows The functions have a priority in order of G 50A MJ 103MTR A gt PAC SF44 SRA gt PAC YT34STA gt PAC YT40ANRA gt PAC SC30GRA gt LMAP02 E Setting details Switch setting Master side SW3 1 OFF Slave side SW3 1 ON 8 2 Using the external input output function Prepare an external input output adaptor to use the external input output function This function cannot be used when the local remote controller operation prohibit is set to prohibit Note that the external emergency stop input can be used 1 External input functions Emergency stop Normal ON OFF and local remote control prohibit enable control can be applied to all units being controlled by inputting the no voltage contact signal from an external source Set the switches as shown below 5 Switch setting Setting details SW3 2 SW33 Do not use external input OFF OFF Carry out Emergency stop Normal with level signal OFF ON Carry out ON OFF with level signal ON OFF Carry out ON OFF and prohibit permit with pulse signal ON ON
2. 2 External output function The ON signal is output when more than one air conditioner is running and the Error Occurrence signal is output when an error is occurring in more than one air conditioner Please refer to the Installation Manual for details 8 3 Disabling the local remote controller s operations from this controller Resetting of the filter sign with the manual remote control can be disabled Setting details Switch setting Disable SW3 4 OFF Enable SW3 4 ON 8 4 When local remote controller and system controller are prohibited Setting details Switch setting Only local remote controller SW3 5 OFF Local remote controller and system controller SW3 5 ON This setting is valid only when SW3 4 is ON 8 5 Changing set temperature display to Fahrenheit display Setting details Switch setting Celsius display C SW3 6 OFF Fahrenheit display F SW3 6 ON INOTE When the DIP switch 3 setting has been changed between ON and OFF always turn the power OFF once The function will not change just by changing the switch setting The function will change after turning the power OFF and ON 9 System limits Master system controller and slave system controller This controller s control range Unit When the system contains only this controller This controller is set as the
3. Setting data record sheet Pattern 9 Operation No Set time Set details SINIJA AJIN gt 5 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT03802X01
4. fare a operation is continued at 29 C and 6 11700 OFF Enable adjustment of the room temperature Lo Pr with the local remote controller is 21 00 OFF ON OFF prohibited n Room temp ere usmer A t oom temp on ma are RER 21 30 OFF ON OFF 3 Setting of weekly program Set the schedule pattern set in step 2 in day units for each group Setting example los Sun Mon Tue Wed Thu Fri Sat roup 1 Pattern 1 Pattern 2 Pattern 2 Pattern 2 Pattern 2 Pattern 2 Pattern 1 Pattern 1 is used for the No setting Pattern 3 Pattern 3 Pattern 4 Pattern 4 Pattern 5 Pattern 6 schedule operation on Sunday in group 1 Schedule operation is not carried out on Sunday in group 2 50 Pattern 9 Pattern 7 Pattern 7 Pattern 8 Pattern 8 No setting Pattern 9 3 2 Schedule operation This controller carries out schedule operation at each set time Operation example The schedule operation for pattern 1 given as an example in step 2 Setting of program on the previous page is explained in this section 8 15 Start cooling operation at 29 C Prohibit adjustment of the room temperature using the local remote controller 10 00 Stop the air conditioner Cancel the local remote controller room temperature adjustment operation prohibit setting and then prohibit ON OFF operations 10 15 Resume operatio
5. PROH flicker and set the prohibited item PERMITT lit All items will be permitted when set to PERMIT PERMIT D This operation is invalid H the SW3 operation prohibit is set to Invalid Always a no display state When JPROH is displayed the prohibited ON OFF MODE and TEMP items wi display 2 Set the item to be prohibited The item can be set by simultaneously pressing the switch for the item to be set while IPROH flickers To prohibit ON OFF Press the switch The ON OFF display will change To prohibit operation mode changeover Press the switch The OPERATION CHANGEOVER display will change To prohibit room temperature adjustment Press the switch The ROOM TEMPERATURE ADJUSTMENT display will change 3 Input the details of the prohibit setting After step 2 light up the items to be prohibited and then press the switch The switch will change from flicker to ON and the set details will be input 5 Input the operation details Press the switch The operation details will be input and the operation No will be incremented by one 4 4 3 Deleting an operation setting 1 Select the operation No to be deleted Refer to section 4 4 1 2 and 3 for the selection methods 2 Delete the settings Press the switch twice in
6. When this controller is the master the group is set and changed TIME DAY SETTING SCREEN The current time and day are set NORMAL SCREEN After setting the schedule schedule operation is carried out with this screen In addition to schedule operation the units can be started and stopped collectively or in groups PROGRAM MONITOR SCREEN The set program contents are monitored PROGRAM SETTING SCREEN The details of the schedule operation are set and changed WEEKLY PROGRAM SETTING SCREEN The pattern set on the PROGRAM SETTING SCREEN is set and changed in day units for each group Explanation of transition operations Press time and switches Press ON OFP Press TEMP and switches Press Switch o 3 Outline of schedule setting and operation 3 1 Outline of setting The schedule is set with this controller using the following procedures 1 Setting of current time and day 2 Setting of program Set the schedule pattern Up to nine types of operations patterns with 16 operations in each pattern can be set Setting example Set details nm pater operation Set time Set Operation ONOFF prohibit A Room temp Set the time to start schedule ERE 99 adjustment operation and the details of the 2 10 00 OFF ON OFF operation 3 1015 ON 27C Enable 12 00 OFF ON OFF With operation 1 cooling with the air l E Room temp conditioner is started at 08 15 13 00 on
7. and WEEKLY PROGRAM SETTING DAY PATTERN SWITCH Use this switch to display the day pattern for WEEKLY PROGRAM SETTING TIMER ON OFF SWITCH Use this switch to stop the schedule function for all groups currently being controlled CLEAR SWITCH Use this switch to clear the program settings PATTERN SWITCH Use this switch to set the schedule pattern No 10 OPERATION SWITCH Use this switch to set the schedule operation No 2 4 Screen configuration 1 2 VOLE 1 POWER ON screen 2 GROUP SETTING SCREEN page 19 When this ie controller is Hfi master Ho i Mew A Pesan na B ni ters l aka J I No time setting I 3 p 3 TIME DAY SETTING SCREEN I v age 12 2 d pag A When time is set E No time settin E l c 5 g ae l l GP N GPO 9 I BI wt le 81 I I 4 NORMAL SCREEN page 10 I l f ee d l l When time is set e ieddeb 4 l ii i ee ee sE korr ARE ui L VH o D 5 PROGRAM MONITOR SCREEN page 11 cron arram D We s an eme FE get S owore ri 830 9 R D 6 PROGRAM SETTING SCREEN 7 WEEKLY PROGRAM page 12 SETTING SCREEN page 14 D WEEKLY SET i g ni ut k ME 8 35 on C eu e Explanation of screens POWER ON SCREEN HO flickers if there is no group information H1 flickers if there is group information GROUP SETTING SCREEN
8. OFF SWITCH COLLECTIVE STATUS DISPLAY SCREEN GROUP STATUS DISPLAY SCREEN If pressed when all groups are stopped all groups will start running If pressed when one or more groups are running all groups will stop If pressed when a registered air conditioner is malfunctioning all groups will stop CAUTION Remote control operations are not possible if HO or H1 is displayed while the power is ON Approx five minutes 2 2 Display sections 10 11 SY TIMER OFF IPROH J PERMIT SCHEDULE PATTERN No The selected group s weekly schedule pattern No is displayed The selected schedule pattern No is displayed MONITOR PROGRAM WEEKLY PROGRAM DISPLAY Monitor display PROGRAM MONITOR screen Program display PROGRAM SETTING screen Weekly program display WEEKLY PROGRAM SETTING screen GROUP NUMBER DISPLAY The group number selected on the Group Setting WEEKLY PROGRAM SETTING Screen is displayed OPERATION STATUS DISPLAY The displayed group s operation status is displayed CURRENT DAY DISPLAY The current day is displayed CONTROL STATUS DISPLAY The currently controlled state is displayed CURRENT TIME DISPLAY The current time is displayed ERROR CODE DISPLAY If an error is occurring the need for inspection is indicated and the error code 4 digit is displayed OPERATIO
9. displav section 6 Interlocked Unit Setting Screen or the unit address No is displayed 2 Selecting the group No 1 Call the Group No Call the group No in which the interlocked unit is to be registered Use the same operations as section 7 1 1 1 Select the group Select the group with the GROUP and switches 2 When the group is selected the corresponding group No will appear at the group No display section 3 After the group is selected if there are registered units the registered unit with the smallest address No will appear Set temperature display section Address No Displayed detail SES pus Group No display section Address No attributes Example When group 1 is not registered and the address 003 indoor unit is registered in group 2 D Pattern No display section is displayed ON OFF o Y GROUP l IER os Operation No display section c a 4 e A unit is not registered in group 1 so is displayed Interlocked Unit Setting Screen group 1 Press switch once ONIOFF o GROUP IL m Ge pp3 Interlocked Unit Setting Screen group 2 9 Calling the registration unit Call the address No of the indoor unit to be interlocked with a registered interlocked unit bv pressing the switch A Selecting the interlocked unit s address No Set the address No of the interlocked unit to be registered with the indoor un
10. each time the switch is pressed indicates that no pattern is set Pattern numbers that are not set will not appear o 0 p m s DM ny dg S k E 5 Deleting a weekly pattern The details of the selected group s weekly program will be deleted no pattern will be set when the Switch is pressed twice in succession 6 Deleting all set schedule details All details set for the program and weekly program can be deleted by holding down the Switch for three or more seconds 5 Troubleshooting 5 1 When COLLECTIVE ON OFF LAMP and ERROR CODE are flickering The air conditioner is stopped because a problem has occurred and operation cannot be continued Check the address of the unit where the error is occurring and the error code and call your nearest MITSUBISHI ELECTRIC supplier or dealer The attribute of the faulty unit flickers CD ON OFF 5D The COLLECTIVE ON OFF lamp flickers GROUP UD aim The error code will flicker The address No of the faulty unit flickers The group No in which the faulty unit is registered flickers 1 If an error occurs while the COLLECTIVE DISPLAY SCREEN is displayed the details of the error for the group with the first faulty will appear 2 If an error occurs while the GROUP STATUS DISPLAY SCREEN is displayed only the details of the error for the currently selected group will appear Confirming the details on an error for a diff
11. section Address No Displayed details Spey d decus No display section Address No attributes Example When groups 1 and 2 are not registered and the address 005 indoor unit is registered in group 3 Pattern No display section appears if nothing is set Dor oc v GROUP rt Wi ER Operation No display section N i S 7 appears if nothing is set Initial Setting Mode Press once QO ON OFF o GROUP EA m ud Select group 2 Press once ON OFF O IF P1 IL U 3 nn 5 UU e Select group 3 The 005 indoor unit is alreadv registered 2 Selecting the unit 1 Select the unit to be registered in the group selected in step 1 The address No displayed in the operation No display section will change in the following order each time the TIME switch is pressed The numbers will change in 10 unit increments when the switch is held down EN D RETE 1 The numbers will appear in reverse order when the TIME switch is pressed Address No setting range Indoor unit LOSSNAY 001 to 050 Local remote controller 101 to 200 Slave system controller i 000 201 to 250 CD ON OFF oc IF GROUP IL d e PT Operation No display section The address No is displayed 2 When registered unit is selected The following will display when the selected unit is already registered in a group controlled with this controll
12. succession The displayed operation setting details will be deleted The default state will be set 4 4 4 Copying the details of a pattern setting All of the operation details of a set pattern can be copied into another pattern Example The details set for pattern 1 can be copied to pattern 2 In this case the contents of pattern 2 will be overwritten 1 Select the pattern number to be copied and display in the display section 2 Hold down the switch for two or more seconds The details set for the copy origin pattern will be saved The operation time and details display sections will flicker 3 Select the copy destination pattern No and display in the display section 4 Hold down the switch for two or more seconds The setting details saved in step 2 will be copied to the copy destination The operation time and details display sections will light To cancel copying of the pattern hold down the switch for two or more seconds after step 1 or 3 The operation time and details display sections will turn ON If the operation is cancelled after step 3 the pattern No will return to the copy origin No 4 5 WEEKLY PROGRAM SETTING screen Set the schedule pattern set in section 4 3 for each day in each group All of the set schedules are deleted DMF o Sun Mon De Wei Thu Pi Sat WEEKLY SET GROUP Dr U tu J The weekly pattern for the currently selected group will flicker The curr
13. unit setting Open the Initial Setting Mode Screen to make these settings 1 The following display will appear when the power to this controller is turned ON OMF gt HO on the group No display section and the COLLECTIVE ON OFF lamp will flicker 2 When group setting information is already set OMF 5 N PA Hi During system startup communication H1 will flicker at the group No display section or gt 10 05 Owhen system startup communication is completed the NORMAL screen will open 3 When there is no group setting information or when the group setting information is changed Press the TEMP and Switches simultaneously while HO shown in step 1 is flickering or when all groups are stopped with the NORMAL screen or GROUP DISPLAY screen shown in step 2 NOTE When opening each screen from step 2 if there is an error in any group the switch operation will be invalid This controller s own address will flicker for two seconds ON OFF S gdi Own address display screen ON OFF o GROUP ma U ees Initial Setting Mode Screen Group Setting Screen Carry out steps 7 1 1 to 7 1 2 from the state shown above 4 Cancel the initial setting mode After setting the group and the interlocked unit hold down the TEMP and switches NOTE simultaneously Save the group setting information and in
14. will flicker XX COLLECTIVE ON OFF lamp will flicker 8 rmen ore AE NOTE 1 The timer is invalid while this mode is input and the schedule function will stop 2 When this mode is cancelled the timer will be validated and schedule operation will resume The schedule following the current time will be started 6 1 2 ON OFF level signal input mode If the ON OFF level signal is input in the external input interface all air conditioners and LOSSNAY units being controlled will be turned ON or OFF This controller slave system controller and local remote controller operations will be prohibited until this mode is cancelled Mon Tue Wed Thu Fri Set 2999582 03 8 30 b o TAR ON will light up when ON is input LON f will turn OFF when OFF is input NOTE When this mode is set ON OFF operations following the schedule from this controller will not be executed Other schedule settings will be executed 6 1 3 ON OFF operation prohibit permit pulse input mode If the ON OFF signal is input in the external input interface all air conditioners and LOSSNAY units being controlled will be turned ON or OFF If the prohibit permit signal is input in the external input interface the slave system controller and local remote controller operations will be prohibited or permitted IPROHJ will flicker when pr
15. LU S d Current time ON OFF status Collective status GROUP STATUS DISPLAY SCREEN All days are lit current day is flickered Schedule pattern No Control status T Current time ON OFF status Group number Q ON OFF o TE E Fess e l ca 4 Operation prohibit state LI D 575 CEXO Operation mode changeover n 3 LTE o limit state 4 1 1 Group selection operation 1 Press the GROUP and switches to select the group to be operated The group No displayed at the group No display section will change as shown below each time the GROUP switch is pressed KR 66 66 Collective gt 1 gt 42 54 3 grr ee eo 50 4 The group No will change in reverse each time the GROUP switch is pressed When the GROUP and switches are pressed simultaneously the Collective Status Display screen will open regardless of the selected group No When Collective is selected the Collective Display screen will open When Group No is selected the screen for the selected group will open When the Group Status Display screen is opened the weekly schedule pattern for the selected group will display The current day will flicker If no operations are made on the Group Status Display screen for ten minutes the display will switch to the Collective Status Display screen 4 1 2 ON OFF operations 1 Se
16. MITSUBISHI ELECTRIC CORPORATION C Mitsubishi Electric Building Air Conditioning Control System System remote controller Type PAC YT34STA Qovrr IU INSTRUCTION BOOK Carefully read this book before use It is recommended to safe keep this book for future reference ANWEISUNGSHANDBUCH Vor Benutzung der Anlage dieses Buch sorgfaltig durchlesen Es wird empfohlen dieses Buch zum Nachschlagen an einem sicheren Ort aufzubewahren MANUEL D UTILISATION Lire attentivement le pr sent manuel avant toute utilisation et le conserver dans un endroit s r pour pouvoir le consulter ult rieurement LIBRO DE INSTRUCCIONES Lea cuidadosamente este libro antes de usar el temporizador Le recomendamos que guarde el libro en lugar seguro en previsi n de consultas Futuras LIBRETTO ISTRUZIONI Leggere attentamente questo libretto prima dell uso Si raccomanda di tenerlo in un luogo sicuro per ogni futura necessit INSTRUCTIEHANDLEIDING Lees deze handleiding aandachtig door voordat u het apparaat in gebruik neemt Het wordt aangeraden om deze handleiding zorgvuldig te bewaren om later indien nodig te raadplegen MITSUBISHI ELECTRIC Dm gB DN DEN Ei CONTENTS Page Safety Precautions eee ee ee eee ee eee ee ee ee eee ee 2 Names and functions of each part 2 1 Appearance ki Se d ENEE a iwa aa ER 2 2 Display sections be 2 3 Operation section 2 4 Screen configuration K ge
17. N DETAILS DISPLAY The details of schedule operation are displayed Operation details ON OFF operation mode cooling heating set temperature operation prohibit ON OFF operation changeover room temperature adjustment enable Display This appears when the power is ON SCHEDULE OPERATION NO The selected schedule s operation No is displayed 2 3 Operation section 9 1 5 6 EAS gt TIMER 2 MONITOR SET GROUP DAY DAY PATTERN ON OFF 7 J 2 e YA i Ga CIE PATTERN OPERATION ON OFF DIK AL DE DIG clock ji i al is ji GROUP SELECT SWITCH Press this to call the required group screen when making various settings MONITOR SET SWITCH Use this switch to change between the NORMAL SCREEN PROGRAM MONITOR SCREEN PROGRAM SETTING SCREEN and WEEKLY PROGRAM SETTING SCREEN CLOCK SWITCH Use this switch to set the current time and program time TEMP SWITCH Use this switch to set the schedule operation ON OFF Select ON OFF or no setting Use this to start or stop the group independently or collectively Operation changeover Select cooling heating or no setting Set Temperature Select set temperature or no setting Prohibit Select operation prohibit enable or no setting DAY SWITCH Use this switch to change the day for the TIME DAY SETTING
18. Prony SET TEMP rm Ei a EX over e b The operation details are displayed The operation time is displayed The operation No will flicker 4 4 1 Setting the program 1 Open the PROGRAM SETTING screen Press the switch on the PROGRAM MONITOR screen PROGRAM will flicker at the upper left when this screen is opened If no operations are made on this screen for ten minutes the display will switch to the Normal screen 2 Set the pattern No displayed at the pattern No display will change as shown on the right each time the switch is pressed 3 Set the operation No The operation No displayed at the operation No display will change as shown on the right each time the switch is pressed 4 Set the operation time 4 91 5 02 Vee t en l EE ERT Sa ate i ire 1 The clock will advance by five minutes when the CLOCK switch is pressed once When the switch is held down the time will advance in five minute increments or sixty minute increments 2 The clock will return by five minutes when the CLOCK switch is pressed once When the switch is held down the time will return in five minute increments or sixty minute increments 4 4 2 Setting the operation details Set the details to be operated at the time set in the previous section Display only the details 1 Set ON OFF to be set No display gt ON gt OFF The state w
19. ak and accumulate around the unit fires or explosions could result W Do not wash this unit with water Washing the unit with water could result in electric shocks or faults W Do not operate switches with wet hands Touching the controller with wet hands could result in electric shocks or faults W Do not use for special applications This product is intended for use with the Mitsubishi Electric building air conditioning control system Do not use for the control of other air conditioners or for other applications Failure to observe this could result in malfunctioning W Do not spray insecticide or flammable sprays onto unit Do not place flammable sprays etc near the unit or spray these directly onto the unit Doing so could result in fires or explosions W Do not use in special environments Using this product in environments containing a high level of oil including machine oil vapours or sulphuric gases etc could result in a drop in performance or damage of parts W Do not press switches with pointed objects Pressing with pointed objects could result in electric shocks or faults W Observe the working temperature range Always observe the working temperature range Serious faults could result if the unit is used outside the working temperature range Refer to the specifications in the instruction manual for the working temperature range If not indicated in the instruction manual the range is 0 C to 40 C 32 C to 1049F W Do not pul
20. changeover limit season changing is set If operation mode changeover limit season changing is set from another system controller cooling heating operations following the schedule will not be executed When cooling limit is set cooling operation following the schedule will not be executed When heating limit is set heating operation following the schedule will not be executed 4 Operation during power failure for this controller The operations set in the schedule will not be executed during a power failure When the power is recovered operation will resume with the schedule active after the restoration time Note that if the schedule operation contains operation prohibit the current state set in the schedule will be restored 4 Operation methods 4 1 Normal screen COLLECTIVE GROUP STATUS DISPLAY SCREEN Display Schedule pattern for each group Only on the Group Status Display screen Current time day Air conditioner ON OFF state Limits and prohibit states set from other system controllers Control state Operation The air conditioner can be turned ON or OFF collectively or in group units The schedule function can be stopped for all groups collectively COLLECTIVE DISPLAY SCREEN Control status Current day Qs xot eme r CD ON OFF o COLLECTIVE Operation prohibit state 1 mm s Reg Operation mode changeover II Se j limit state e
21. egistered as the interlocked unit This also applies when searching or deleting 3 Calling the registration unit 4 Selecting the interlocked unit s address No 5 Registering the interlocked unit 6 Searching for interlocked units 7 Cancelling the interlock setting Y Go to step 7 1 4 or 7 1 1 INOTE When registering the interlocked unit if an indoor unit and interlocked unit in a certain group are to be linked always register the indoor unit with the smallest address No in the group for interlocking If the unit is not registered for interlocking the interlocked unit cannot be operated with the local remote controller If there are several indoor units to be linked with the interlocked unit register all indoor units for interlocking 1 Calling the Interlocked Unit Setting Screen 1 Open the Interlocked Unit Setting Screen from the Group Setting Screen Press the MONITOR SED switch Qu o IL ni DoD GROUP ei O Initial Setting Mode Screen Group Setting Screen The screens will alternate between the Group Setting Screen and Interlocked Unit Setting Screen each time the switch is pressed Pattern No display section or the attributes are displayed Que o x uo GROUP IL F3 4 E m Utan eu 4 Operation time display section UU J e or the interlocked unit s address No is displayed L o Operation time
22. en a no Ede ete dane dE ed saka scu ale satin ge Saja ste IO ct O E tae nee 3 Outline of schedule setting and operation 3 1 Outline of setting H EE ANAA A EHS PER FTP CAA PEER ee REP bi can Wi Doi l ea 3 2 Schedule operation ue 4 Operation methods eee M4 4 1 Normal screen COLLECTIVE GROUP STATUS DISPLAY SCREEN 10 4 As 1 Group selection operation Pia dak ja ak ia E EIERE mna eee Sesion 10 4 122 ON OFF operations I E wel 4 1 3 Stopping the schedule operation collectively for all groups ee 4 1 4 Display SE 4 2 PROGRAM MONITOR screen 4 3 TIME DAY SETTING screen 4 4 PROGRAM SETTING screen 4 4 1 Setting the program 4 4 2 Setting the operation details 4 4 3 Deleting an operation setting 4 4 4 Copying the details of a pattern setting 4 5 WEEKLY PROGRAM SETTING screen 4 5 1 Setting the operation pattern 5 us TEM 5 1 When COLLECTIVE ON OFF LAMP and ERROR CODE are flickering 5 2 When only the Error Code is flickering Stewie newt pest nd Er tn di piu qi XT 6 External input and output functions 6 1 External input uil led ue IL Di des esr 6 1 1 Emergency stop input mode 6 1 2 ON OFF level signal input mode sse 6 1 3 ON OFF operation prohibit permit pulse input mode 6 2 External output Fure asked Na Nan Mek ELO Se See Sadr T Initial settings 7 i When this controller is master svstem EEE i l REE ENE 1 1 Set
23. ently selected group No is lit and displayed 4 5 1 Setting the operation pattern 1 Open the WEEKLY PROGRAM SETTING screen Press the switch on the PROGRAM SETTING screen WEEKLY SET will flicker on the left of the screen when the screen changes If no operations are made on this screen for ten minutes the display will switch to the Normal screen 2 Selecting the group No 1 The group No displayed at the group No display will change in the following order each time the GROUP switch is pressed The display will change in a one second cycle when the switch is held down Group numbers that are not set will not appear EE ee EN gt 50 2 The display will change in reverse when the GROUP switch is pressed NOTE With this controller the pattern can be set regardless of the unit models in the group Example A heating operation pattern can be set for a group consisting only of cooling dedicated models When setting a weekly program check the unit models in the group and the pattern setting details 3 Selecting the set day The pattern No displayed at the weekly pattern setting No display will change in the following order each time the DAY switch is pressed The selected day pattern will flicker Sunday Pattern No Monday Pattern No gt gt Saturday Pattern No f 4 Selecting the day No Each flickering pattern No will change in the following order
24. er Example When unit 011 registered in group 23 is called with group 3 Pattern No display section The registered group No and registered unit attributes alternately display ON OFF o N OD E 23 BI rv ui 3 Registering the unit into a group 1 Register the unit selected in step 2 into a group With the group No and unit address selected in steps 1 and 2 displayed press the switch The registration process will be completed with this step The address No and attributes will appear when correctly registered Pattern No display section The attributes are displayed when correctly registered DMF o ary GROUP u Og 5 4 Operation No display section u harr og The address No is displayed O Registration complete screen The address 005 indoor unit is registered in group 3 2 Registering a separate unit Carry out steps 2 and 3 to register a different unit in the same group Carry out steps 2 and 3 to register a unit in another group NOTE ALOSSNAY unit cannot be registered in a group containing indoor units When registration is attempted these will not be correctly registered and 88 will flicker on the screen If the indoor unit LOSSNAY and local remote control are already registered in another group they cannot be registered in a different group However the slave system controller can also be registered in a different group 4 Searching f
25. erent group Using the switch select the group with the error and check the displayed error details NOTE If an error occurs in a group other than that displayed on the GROUP STATUS DISPLAY SCREEN the COLLECTIVE ON OFF lamp will flicker 5 2 When only the Error Code is flickering The air conditioner will continue running but there may be a problem Check the error code and call your nearest MITSUBISHI ELECTRIC supplier or dealer DON OFF Mon Tue Wed Thu Fri Sat AI ur GIS TA ERROR CODE 9 The maintenance code flickers The selected group No is displayed 1 If an error occurs while the COLLECTIVE DISPLAY SCREEN is displayed the details of the error for the group with the first problem will appear 2 If an error occurs while the GROUP STATUS DISPLAY SCREEN is displayed only the details of the error for the currently selected group will appear 6 External input and output functions When using the external input and output cables provided with the remote controller 5 wire cable for input and 4 wire cable for output are provided 6 1 External input 6 1 1 Emergency stop input mode If an emergency stop signal is input in the external input interface all air conditioners and LOSSNAY units being controlled will stop This controller slave system controller and local remote controller operations will be prohibited until the emergency stop input is cancelled riter OFF
26. ill change as shown on the right each time the ON OFF switch is pressed Set to No display if this setting is not required 2 Set the operation mod The mode will change as shown on the right each time e the switch is pressed Set to No display if this setting is not required 3 Set the temperature ae te AR isplay gt KE gt XI COOL HEAT 1 The temperature will change as shown below each time the TEMP switch is pressed The temperature will change continuously in 1 increments when the switch is held down L gt 19 gt 20 gt gt 28 te gt gt 2 The temperature will change as shown below each time the TEMP switch is pressed The temperature will change continuously in 1 increments when the switch is held down Et 28 27 5 4 Set operation prohibit gt 19 el The DIP switches must be set to prohibit operations following the schedule with this controller Refer to section 8 Setting the functions 1 Set whether to prohibit or enable operations with the local remote controller The state will change as shown below each time the switch is pressed e No display PROH flickers gt PROH ON gt f A To not set Leavet To set prohibit Set to To enable Set to he display at No display
27. ion No Monitoring the set program details 1 Open the PROGRAM MONITOR screen Press the Switch on the Normal screen MONITOR will appear at the upper left when the screen is opened 2 Set the pattern No The pattern No displayed at the pattern No display section will change as shown below each time the switch is pressed Patterns that are not set will not appear 47627 BN anna ug 1 3 Set the operation No The operation No will change in the order of set times each time the Switch is pressed Operation numbers that are not set will not appear 4 The details of the program having the set pattern and operation numbers will appear NOTE On this screen each operation is sorted and displayed in order of the set time 4 3 TIME DAY SETTING screen The current time and day are set and changed on this screen Atime notification can be issued A time notification is issued to collectively set the current time of system controllers and remote controllers having a clock function The set day flickers e TA PAN S LILL The time notification setting lights up The time flickers The time and day settings light up 1 Open the TIME DAY SETTING screen Press the CLOCK and switches simultaneously on the Normal screen 2 Set the time 1 The clock will advance by one minute when the CLOCK switch is pressed once When the switch is held down the time will advance in one mi
28. isable controller or with another controller function System Celsius Fahrenheit display Set the set temperature display to a Celsius or Fahrenheit display At To prohibit an operation set whether to prohibit only the remote controller or 3 Prohibit range S to also prohibit the other controllers System eee own Set the schedule timer s address Refer to the Installation Manual External input Emergency stop level input ON OFF level input ON OFF and operation prohibit enable pulse input External output ON OFF status output error normal state output Indoor unit LOSSNAY Maximum 50 units Number of indoor units and 1 to 16 units The indoor unit and LOSSNAY cannot be registered in the same LOSSNAY in one group group Number of local remote 0 to 2 units Number of controls in one group ul registered Number of system 0 to 4 units Note that this includes the number of local remote controllers units controllers that can be used in one group controlled by one group 2 0 to 3 units in a group having one local remote controller Number of indoor units O to 16 units interlocked with one LOSSNAY 1 Refer to page 30 2 This controller schedule timer is one of the system controllers 3 Refer to page 28 4 Check the operation status operation mode set temperature etc of other air conditioners with the system controller being used 75 These displayed details are the schedule setting details These are not the air conditione
29. isplayed 7 Canceling the interlock setting Cancel the interlock setting of the indoor unit and interlocked unit 1 Call out the screen displayed after the interlocked unit is set or the screen on which the interlocked unit was searched OMF o IT ni IL HI 503 Displays alternately OMF o LE m Li 3g d 2 The interlock setting will be cancelled when the switch is pressed twice in this state QW o Displays alternately OMF o ECC Di 30 9 The attribute display will change to when completed normally 7 1 3 Collective deletion All group setting information and interlocked unit setting information can be deleted This function is valid only when this controller is the master 1 Display the Group Setting Screen or Interlocked Unit Setting Screen 2 All set information will be deleted when the switch is held down for three or more seconds in this state QDONOFF D The COLLECTIVE ON OFF lamp flickers and 88 888 and 88 flicker at the group No display section the operation No O During collective deletion communication display section and operation time display section respectively process ONOFF STN Medi e HO flickers at the pattern No display section O Initial state 8 Setting the functions Function setting switch CN 1
30. it selected in step 3 After selecting the indoor unit with step 3 press the TIME switch The address No of the interlocked unit will change in the following order each time the switch is pressed The numbers will change in 10 unit increments when the switch is held down 00 Q2 S 50 T The address numbers will appear in reverse order when the switch is pressed Pattern No display section The attributes will disappear when the switches is pressed quor o Operation No display section Set to the address No of the interlocked unit to be registered 5 Registering the interlocked unit 1 When the switch is pressed in the state shown in step 4 the interlocked unit will be registered as interlocked to the displayed indoor unit The following type of display will appear when the unit is correctly registered OMF o Ir IL i ca e c3 Lu e The address No of the set indoor unit the address No of the interlocked unit and the attributes alternately display QW o KE sw ll 1 8i an l If not correctly registered 88 will flicker instead of the attribute 2 Set the next interlocked unit Carry out steps 3 4 and 5 to register a different indoor unit in the same group to the interlocked unit Carry out steps 2 3 4 and 5 to register an indoor unit in a different group to the interlocked unit Carry out
31. l or twist the transmission cables Doing so could result in fires or faults W Do not disassemble this unit Touching the internal PCBs etc is hazardous and could result in fires or faults W Do not wipe this unit with benzene thinner or chemical rags Using these matters could result in discoloration or faults If the unit is heavily dirtied wipe off with a cloth wetted in diluted neutral detergent and then wipe again with a dry cloth 2 Names and functions of each part 2 1 Appearance This controller has two operation modes One is the COLLECTIVE STATUS DISPLAY Screen for making operations and settings for all air conditioners and the GROUP STATUS DISPLAY Screen for making operations and settings for air conditioners in each group Refer to section 4 Operation methods page 10 for details 1 ON OFF e 2 FM 4848988 JET a ge ger 78 es 88 88 25 BB o 3 DAY PATTERN ce clc c5 E5 ES Cy MODE PROMI CLEAR bt SE SOE PACYTSASTA MONITORISET NGR COLLECTIVE GROUP DISPLAY Indicates which mode is selected COLLECTIVE COLLECTIVE STATUS DISPLAY Screen GROUP GROUP STATUS DISPLAY Screen COLLECTIVE ON OFF LAMP ON One or more group is running Also ON when a sequential unit is running OFF All groups are stopped Flicker Registered air conditioner is malfunctioning COLLECTIVE ON
32. lect the group of collection state to be operated with the step Group selection operation above 2 Press the ON OFF switch will appear at the ON OFF status display when the controller is running Nothing will appear when the controller is stopped 4 1 3 Stopping the schedule operation collectively for all groups 1 Hold down the TIMER ON oFP switch for three seconds TIMER OFF will appear at the control status display section when the schedule operation is stopped and the schedule operation will stop ER TIMER OFF will not appear during schedule operation When an emergency stop is input Tmen OFF will flicker The CIMER ON OFF switch operation is invalid while TIMER OFF is flickering 4 1 4 Display will appear when operation prohibit is set from another system controller If ON OFF operation prohibit is set the operation cannot be started or stopped from this controller 2 If operation mode changeover limit cooling limit is set from another system controller 5 will flicker i 1 will flicker when operation mode changeover limit heating limit is set 4 2 PROGRAM MONITOR screen The set program details are monitored Pattern No T OMF o MONITOR parenn i S i Fal SETTEMP men d Ia on 5 el ae reir SC Operation time I Operat
33. master system controller In this case the group is set with this controller Control by the slave system controller of a unit not within the control of the master system controller Slave system controller or Master system controller Master system controller control range This controller s control range Unit Unit When this controller is controlled by another system controller This controller is set as the slave system controller In this case the group is not set with this controller INOTE The following types of group settings are not possible Control of a common group with two or more master system controllers Master system Master system controller 1 controller 2 Setting of a slave system controller exceeding the control range of two or more master system controllers Master system controller 1 Slave system controller SG gt Master system controller 2 10 Specifications 10 1 Product functions This controller can control up to 50 air conditioners and LOSSNAY with a daily schedule either collectively or in groups This controller has only a schedule setting function and must be used with another system controller When used independently only the air conditioner s ON OFF status and error status will be monitored operation status display In addition to schedule setting the units can be turned ON OFF and stopped and the timer can be reset either collec
34. n at 27 C Prohibit operation of the local remote controller 12 00 Stop the air conditioner Prohibit ON OFF operations using the local remote controller 13 00 Start cooling operation at 25 C Prohibit adjustment of the room temperature using the local remote controller 17 00 Stop the air conditioner Cancel the local remote controller room temperature adjustment operation prohibit setting e e e 21 00 Stop the air conditioner Prohibit ON OFF operations using the local remote controller The details set for the final operation will be held until schedule operation starts on the next day Room Room temperature ON OFF l Keeser adjustment i adjustment Local remote ON OFF ON OFF i controller prohibit Prohibit 4 state All enabled L ON 29 C cool 27 C cool Air conditioner orp dh operation state 8 15 10 00 10 15 12 00 NOTE 1 Even if a schedule operation is being executed from this controller the air conditioner can be operated using the local remote controller 2 Operations when operation prohibit is set If operation prohibit is set from another system controller the schedule operation of the set prohibit item will not be executed The prohibit items set from the other system controllers are ON OFF ON OFP operation mode changeover MODE and room temperature adjustment TEMP 3 Operation when operation mode
35. nute increments ten minute increments and one hour increments 2 The clock will return by one minute when the CLOCK switch is pressed once When the switch is held down the time will return in one minute increments ten minute increments and one hour increments 3 Set the day The day displayed in the day display section will flicker in the order of Sunday Monday Tuesday Saturday Sunday each time the DAY switch is pressed 4 Set the time notification The display at the time notification setting and display section will change as shown below each time the switch is pressed No display ON t Set this to ON when a time notification is to be issued 5 The set clock day and time notification can be cleared to the previous values by pressing the switch 6 The set time day and time notification settings will be input when the switch is pressed The seconds unit will be set to 0 seconds If the time notification is enabled the time input with this operation will be notified INOTE 1 To cancel the setting carry out step 1 to return to the Normal screen The changes made to the time setting will be cancelled 2 The Program Setting screen and Weekly Program Setting screen cannot be opened if the time and day are not set 4 4 PROGRAM SETTING screen The details of the schedule operation are set and changed The pattern No will flicker CT o WEEKLY SET 77
36. ohibit is input 2 3 3 8 m B e jU H PROHJ will turn OFF when permit is input GROUP Kol n TA U 8 30 La e ON will light up when ON is input LON will turn OFF when OFF is input NOTE 1 The timer is valid even when this mode is input and the schedule operation will be executed 2 The prohibit permit setting range follows the DIP SW3 5 setting state Refer to section 8 Setting the functions for details on the DIP switches 6 2 External output The ON signal is output when more than one air conditioner is ON and the Error Occurrence signal is output when an error is occurring in more than one air conditioner 7 Initial settings When connecting multiple svstem controllers designate the svstem controller with manv functions as the master and set the system controllers with few functions as the slaves Refer to section 8 Setting the functions 8 1 Using with master system controller for details on the master slave settings If this system is controlled by the master system controller carry out the initial settings with the master system controller In this case this system will use the slave settings and does not require initial settings 7 1 When this controller is master system The initial settings include the following items Group setting Interlocked
37. or registered units The address numbers of all units registered in a group can be checked 1 Using step 1 select the group to be searched 2 The address numbers of the registered units will appear in order of smallest number each time the switch is pressed Out o c Hana UI 595 e Dress switch once Dar o GROUP RE H 105 o Press Switch once Qo 0 wor D 03 ana Press PROHIBIT switch once For SC if registered in another group the pattern No section attributes will flicker 3 If a single unit is not registered will display b Deleting a unit from a group 1 Using steps 1 and 2 call out the address No of the unit to be deleted When the Switch is pressed twice in this state the unit registered in the group will be deleted DONOFF c E IF GROUP IL ma UI nin 5 LILI e 2 Press switch twice OMF c PN A The attribute display will disappear and will be displayed when correctly U 205 completed 7 1 2 Setting the interlocked units Set that units interlocked with each group can be run in linked Set the interlocked unit after setting each group The interlocked units cannot be set until the units are registered in the group in which interlocked units are to be set 1 Calling the Interlocked Unit Setting Screen v 2 Selecting the group No Select the group to be r
38. r operation status monitor details 10 2 Main specifications Item Details Power source 30VDC supplied from outdoor unit or power supply unit for transmission line type PAC SC34KUA Power consumption 1W Working environment conditions Temperature 0 to 40 C humidity 30 to 90 RH with no dew condensation Weight 0 2kg Outline dimensions HxWxD 120 x 130 x 18 Setting data record sheet Pattern 1 Pattern 2 Operation Set time Set details Operation Set time Set details No No 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 Pattern 3 Pattern 4 Operation Set time Set details Operation Set time Set details No No 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 Setting data record sheet Pattern 5 Pattern 6 Operation Set time Set details Operation Set time Set details No No 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 Pattern 7 Pattern 8 Operation Set time Set details Operation Set time Set details No No 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16
39. steps 2 3 4 and 5 to register a different indoor unit to a different interlocked unit 6 Searching for interlocked units Search to find which indoor unit the interlocked unit is linked to 1 Carry out step 4 to display the address No of the interlocked unit for which the setting is to be confirmed Select the interlocked unit with the switch is displayed The indoor unit address or Ow GROUP H tanya The address No of the interlock unit NISI E 9 to be searched for is displayed Press the PROHIBIT switch in the above state 2 When interlocked unit is set QW o De wie T Ul 203 e The address No and attribute of the interlocked indoor unit will appear Displays alternately olor o LE Fa n ui 30 al The interlocked unit s address No and attribute will appear Ifthe switch is pressed again in this state the other units linked to the interlocked unit can be confirmed Example Indoor unt 001 group 1 002 group 2 The following details are searched for Press PROHIBID switch once gt Indoor unit address 001 and attributes 4 Interlocked unit address 030 and attributes Press Switch once Indoor unit address 002 and attributes amp Interlocked unit address 030 and attributes Press Switch once 3 When no unit is linked to the interlocked unit QW o Operation No display section is d
40. terlocked unit setting information etc with this step and then carry out system startup communication The Group Setting Monitor Screen will open when completed Refer to step 2 If no operations are made on this screen for ten minutes the display will automatically switch to the Normal screen Note that if the group setting information has not been saved the screen will not change automatically Do not turn the power OFF during system startup communication while H1 is flickering The group setting information etc will not be saved in the memory if the power is turned OFF 7 1 1 Setting the group Register the indoor unit LOSSNAY slave system controller and local remote controller for each group Register the LOSSNAY to be interlocked with the indoor unit using the interlocked unit setting 1 Select the group v 2 Select the unit Y 3 Registering the group into the unit 4 Searching for registered units 5 Deleting a unit from a group Y Go to step 7 1 4 or 7 1 2 1 Select the group e ns 1 The group No displayed in the group No display will change each time the GROUP Switch is pressed The numbers will display in reverse when the switch is pressed 2 After the group is selected if a unit is registered in the group the minimum address No unit will appear The attributes for that group will appear after two seconds Operation No display
41. ting the group Kom wan Kw Rawa dw a OF 1 2 Setting the interlocked units 1 3 Collective deletion E Set tting the functions e M mIeDOB 8 1 Using with master system controller i 8 2 Using the external input output function M Mn 3 8 3 Disabling the local remote control s operations from this controller 8 4 When local remote controller and system controller are prohibited 8 5 Changing set temperature display to Fahrenheit display ARS RRS aes Hans dia ti gebla NM ag Aa Dg AA eyes eyes ese 2 GI 9 System limits U 1 0 Specifications wesesessssssssusssssessesscsecessssessssssssessosecsecesessssssssesssesesseseeeessssssesessseemeceeccecee 3 4 m 10 1 d Product functions Ee ME eee eee MN SE eee ee ee EE a eter eter ee nc E hier ee er ne ee A TR 31 T 7 7 e 1 1 Safety Precautions W Always read these Safety Precautions before starting and perform the installation work correctly W The dangers and degree that could occur if handling is mistaken are ranked with the following symbols ANWARNING When fatalities or serious injuries could result if handling is mistaken ANCAUTION When personal injury or damage to house or assets could result if handling is mistaken W After reading this manual store it in a safe place together with the installation manual for future reference When changing users always give this manual and the installation manual to the new
42. tively or in groups with switch operations The details of the functions are listed below lt List of system remote controller functions gt Function Details Operation ON OFF ON OFF operations can be carried out collectively or for each group Timer reset 4 The timer setting details can be disabled collectively ON OFF Setting details COOLHPAT Room temperature adjustment TEMP Operation prohibit ON OFF operation mode setting temperature Normal Timer Number of setting patterns 9 i f nctions Number of settings Operation for a week can be set by selecting one of nine patterns for each day Number of operations Up to 16 operations can be set in one pattern Time setting unit The item can be set in five minute units Time The current time and day can be displayed Monitor Error The address of the faulty unit and the error code are displayed on the LCD ON OFF status 5 The ON OFF status of the unit is displayed on the LCD when GROUP is selected G 2 Set the unit indoor unit LOSSNAY remote controller slave system roup setting Operation controller group Interlocked unit setting Set the LOSSNAY and indoor unit interlock Master system Set the master and slave system controllers controller Slave system controller 1 Default Operation prohibit setting Set whether to prohibit operation with the local remote control using this setting Enable d
43. user ZA WARNING W Unit must not be installed by user Always contact your dealer or a specialist to install the unit Improper installation by the user could result in electric shocks or fires etc W Check the installation state Always check that the unit is installed on a solid place where it will not fall off W Check the rated power supply An incorrect power supply could result in fires or unit trouble W Stop immediately when error occurs Continuing operation in an erroneous state could result in trouble electric shocks or fires etc If any abnormality is sensed burning smell etc always stop the operation turn the power switch OFF and contact your dealer W Unit must not be moved and re installed by user Improper installation by the user could result in electric shocks or fires etc Always contact your dealer or a specialist when the unit must be moved W Unit must not be disposed by user Contact your dealer when the unit must be disposed of W Never modify or repair the unit Improper modifications or repairs could result in electric shocks or fires etc Always consult your dealer for repairs W Stop operation if operation is inhibited with an error display or if a fault occurs Continuing operation could result in fires or faults Contact your dealer Z CAUTION W Do not place hazardous objects near unit Do not install this unit where flammable gases could leak If flammable gases le