1. e Precautions Make sure Patient Safety Straps are secured before moving Never use Patient Safety Straps to pull the HoverJack air patient lift as they may tear Move the HoverJack air patient lift using the Transport Straps at the head end and or the handles located along the top perimeter When moving a patient on the inflated HoverJack air patient lift use caution and move slowly Additional caregivers are recommended when moving a patient over 750 lbs 340kg Never attempt to move a patient on an un inflated HoverJack air patient lift Route the power cord in a manner to ensure freedom from hazard Avoid blocking the air intakes of the air supply Never leave patient unattended on an inflated device Use this product only for its intended purpose as described in this manual Only use attachments and or accessories that are authorized by HoverTech International WARNING For safety always use a minimum of two caregivers while using the HoverJack air patient lift CAUTION Avoid electric shock Do not open Air Supply WARNING Reference product specific user manuals for additional operating instructions HoverJack patient air lift system is not UL classified A HO V ERTECH SZ International RevA HJManual 3 HOVERJACK user MANUAL Introduction Using the HoverJack Air Patient Lift In the event of a patient fall the HoverJack air patient lift is log rolled under the patient The Hovertech Air Sup
2. HoverJack amp Technology 4 HJManual Consistent utilization of the HoverJack air patient lift dramatically reduces back injuries to staff that are caused by manually lifting patients who have fallen In addition fewer staff members are required and the patient is lifted in a very comfortable manner When considering Fall Prevention guidelines the HoverJack air patient lift is a critical component of a program that addresses the safety of the patient and the caregiver if a patient does fall AA SZ International RevA HOVERJACK user MANUAL Part Identification Air Patient Lift Transport Strap Patient Safety Straps 2 DO NOT USE TO TRANSFER Transfer Handles 8 Label Includes Model Serial and Instructions for use Red Deflate Cap and Valve 4 Total Inflate Cap and Valve 4 Total HOVERTECH SZ International RevA HJManual 5 HOVERJACK user MANUAL Part Identification Air Supply Carrying Handle Attachment Hook Power Cord Strap Hose Release Button Control Panel Label Hose Nozzle Power Cord Q S 0 0 K Euro Aus ht ational ernationa HJManual RevA HOVERJACK user MANUAL Air Supply Keypad Functions Adjustable Speed Indication Power Indication ABJUSTABLE STANDB 2 e Zsa HOVERTECH 2222 SS International HOVERMATT 28 O 34 39 O 50
3. Rev A HOVERJACK user MANUAL AIR SUPPLY NO USER SERVICEABLE PARTS Only qualified service personnel shall perform repairs on the HoverTech International Air Supply AAA HOVERTEC lt d nternational Rev A HJManua HOVERJACK user MANUAL Part Identification Control Panel LPs Cover lt g Hose Attachment Snap Air Filter Cover Handle Attachment Hook Metal Cover Foot Grounding Pin Used for a Ground Continuity Bond Test Information Labels Power Cord Clamp Circuit Breakers Power Cord Strap Bumpers Power Cord US UK Euro Aust AA SZ International HJManual Rev A 18 HOVERJACK user MANUAL Power Cord Clamp Replacement International 8 io HOVERJACK user MANUAL Handle Replacement 1 Remove the damaged handle by unscrewing the socket head screw from the barrel nut using two 5 32 allen wrenches as shown 2 Attach the new handle by reversing the process When tightening the screw be sure that the handle can rotate easily The screw is treated with thread lock to secure it in place Carrying Handle Attachment Hook Barrel Nut 7 n 5 32 All Wrench Socket Head Screw 5 32 Allen Wrench 20 HOVERTECH SZ International HJManual Rev A HOVERJACK user MANUAL Feet or Bumper Replacement 1 The feet and bumpers are
4. be a minimum 100 service charge plus shipping costs Lead time for repairs is approx 2 weeks Please refer to the Return and Repairs section of this Manual for return instructions This warranty is not an unconditional guarantee for the lite of the product Our warranty does not cover product damage that may result from use contrary to Manutacturer s instructions or specifications misuse abuse tampering or damage due to mishandling Warranty specifically does not cover product damage that may result from using an air supply that produces more than 3 5 psi to inflate the HoverJack air patient lift Equipment that has been neglected improperly maintained repaired or altered by someone other than an authorized representative of Manufacturer or operated in anyway contrary to the operating instructions shall void this warranty This warranty does not cover normal wear and tear Component parts particularly any optional equipment valve caps their attachments and cords will show wear with use over time and eventually may need to be refurbished or replaced This normal type of wear is not covered by our warranty but we will provide prompt high quality repair service and parts at a nominal cost A HO V ER TECH SZ International 29 RevA HJManual HOVERJACK user MANUAL Warranty Statement Statina Healthcare s liability under this warranty and on any claim of any kind for any loss or damage arising out of connected with
5. h 9 amp kl Adjustable Pressure Setting Transfer Speed High sack Transfer Speed Low The Adjustable Keypad function has four different settings Pressing the button once will result in the lowest inflation setting available A second press of the button increases the air pressure and rate of inflation Pressing the button a third time will again increase the rate of inflation A fourth press of the button results in the highest inflation rate and air pressure available for HoverTech Accessories The STANDBY button may be pressed at any time to cease all air flow NOTE The LED will indicate the inflation speed by the number of flashes i e two flashes equals the second inflation speed All of the settings in the Adjustable range are substantially lower than the HoverMatt and HoverJack settings The Adjustable function is not to be used for transferring it is only for use with HoverTech Accessories which require a lower pressure for slow inflation Standby Used to stop inflation air flow HoverMatt 28 34 For use with 28 amp 34 HoverMatt Air Transfer Mattresses HoverMatt 39 50 amp HoverJack For use with 39 8 50 HoverMatt Air Transfer Mattresses and 32 amp 39 HoverJack Air Patient Lifts A HO V ERTECH SZ International 7 RevA HJManual HOVERJACK user MANUAL Instructions for Use 1 9 Place HoverJack air patient lift on floor next to the patient making
6. held in place by a self adhesive backing Use a small flat bladed screwdriver to pry up an edge and gently remove the foot or bumper 2 Clean surtace thoroughly to remove any excess adhesive that may have been left behind Apply the new part by removing the backing material and position as shown Press firmly to ensure adhesion International 21 8 CA Rev A HJManual HOVERJACK user MANUAL Hose Removal 1 Remove the damaged hose by lifting the dust cover slightly and unsnapping the hose from the side of the unit as shown 2 Push the release button at the top of the unit to remove the hose 3 Attach the new hose by reversing the process Hose Hose Release Button Dust Cover Hose Attach ment Snap 22 SZ International HJManual Rev A HOVERJACK user MANUAL Air Filter and Air Filter Cover Replacement To Remove Air Filter Covers 1 Disconnect hose from unit See page 22 2 Remove the two phillips head screws on each side to detach the air filter covers 3 Re attach the new air filter covers and screws To Remove Air Filters 1 Follow the steps shown above to remove air filter covers 2 Remove air filters and replace 3 Re attach the air filter covers and screws For air tilter cleaning instructions please refer to Page 15 HOVERTECH SZ International 23 RevA HJManual HOVERJACK user MANUAL Dust Co
7. ke keke k k k k kr 31 A SZ International RevA HJManual 1 HOVERJACK user MANUAL Symbol Reference Attention Please read accompanying documents A Type BF Applied Part Declaration of Conformity to Medical Device Directive Functional Earth Ground Alternating Current NS 43SW Underwriters Laboratory Agency Approval 120 V Medical Equipment with respect to electrical shock fire and mechanical hazards only in accordance with UL 60601 1 IEC EN 60601 1 CAN CSA 22 2 No 601 1 230 V Medical Equipment with respect to electrical shock fire and mechanical hazards only in accordance with UL 60601 1 IEC 60601 1 2 CAN CSA 22 2 No 601 1 80 C 176 40 C 4 40 70 u 10 96 This End Up Temperature Humidity Date of Manufacture Keep Dry 2 AA HOVERTECH SZ International HJManual Rev A HOVERJACK user MANUAL Intended Use and Precautions e Indications Patients unable to assist in their own vertical lift such as after a fall Patients whose weight or girth poses a potential health risk for the caregivers responsible for lifting or moving said patients e Contraindications Patients who are experiencing thoracic cervical or lumbar fractures that are deemed unstable unless using in conjunction with a spinal board e Intended Care Settings Hospitals Long term or extended care facilities
8. or resulting from the design manufacture sale delivery installation repair or operation of its products whether in contract or tort including negligence shall not exceed the purchase price paid tor the product and upon expiration of the applicable warranty period all such liability terminates The remedies which this warranty provides are exclusive and Statina Healthcare Australia shall not be liable for any incidental or consequential damages There are no warranties express or implied which extend beyond this warranty statement The provisions of these warranty clauses are in lieu of all other warranties expressed or implied and of all other obligations or liabilities on Statina Healthcare Australia s part and neither assumes nor authorizes any other person to assume for Statina Healthcare any other liability in connection with Manufacturer sale or lease of said products Statina Healthcare Australia makes no warranty of merchantability or fitness for a particular purpose There is no warranty that the goods will be fit for a particular purpose By accepting the goods the buyer acknowledges that buyer has determined the goods are suitable tor the buyer s purposes MANUFACTURER S SPECIFICATIONS ARE SUBJECT TO CHANGE AA HOVERTECH SZ International HJManual Rev A 30 HOVERJACK user MANUAL Returns and Repairs All products being returned to Statina Healthcare Australial must have a Return Goods Authorization Numb
9. sure the chamber with Valve 4 is on the top and the chamber with Valve 1 is against the floor For safety always use a minimum of two caregivers when operating the HoverJack air patient lift Make certain that all four red capped deflation valves are capped tightly to maintain inflation Log roll patient onto the deflated HoverJack air patient lift and position patient with feet at the valve end where indicated The patient can be placed on top of the HoverJack air patient lift using the HoverMatt Air Transfer System See HoverMatt instructions If the HoverMatt is used make certain that the HoverMatt and patient are properly centered on the HoverJack air patient lift Always deflate the HoverMatt air transfer system prior to inflating the HoverJack air patient lift Using buckles secure patient safety straps around the patient Plug HoverTech International Air Supply power cord into an electrical outlet Hold hose against inlet Valve 1 of HoverJack air patient lift Turn on Air Supply to the highest inflation level to begin inflation with valve 1 HOVERJACK Use for sizes 32 amp 39 When fully inflated remove hose Valve will automatically close keeping chamber inflated Using the same process move to Valve 2 Valve 3 and Valve 4 in exact succession 10 Turn off air supply by pressing standby button and cap valves 11 Transfer from HoverJack air patient lift onto adjacent surfac
10. 0 30 dip in U For 25 cycles lt 5 U gt 95 dip in U for 5 seconds 6 kV contact 8 kV air 2 kV for supply mqins 1 kV for input output lines 1 kV line s to line s 2 kV line s to earth lt 5 gt 95 dip in U For 0 5 cycle 40 60 dip in U For 5 cycles 70 30 dip in U For 25 cycles lt 5 gt 95 dip in U for 5 seconds Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the HoverTech International Air Supply requires continued operation during mains interruptions it is recommended that the HoverTech International Air Supply be powered from an Uninterruptible power supply or a battery Power frequency magnetic fields should be at levels characteristic of a typical commercial or hospital environment NOTE is the AC mains voltage prior to application of the test level HJManual AA HO V ERTECH SZ International RevA HOVERJACK user MANUAL Electromagnetic Compatibility Chart For HTAIR 2300 ONLY Guidance and Manvfacturer s Declaration Electr
11. HOVERJACK user MANUAL Table of Contents Symbol References ake 02 Intended Use and Precautions 03 HOVERJACK Introduction 04 Part Identification Air Patient kuz 05 Part Identification Air SUDD Y s 44 2a 444554453 4445545440452442 iid ER ds 06 Air Supply Keypad Functions kk kk 07 nsirucions Ar T 08 Product Specifications Required Accessories 09 10 Electromagnetic Compatibility Chart A E 11 14 Cleaning amp Maintenance 15 Frequently Asked Questions esee 16 AIR SUPPLY 17 Part Identification sss eem k k k 18 Power Cord Clamp Replacement _ 19 Handle Replacement sese 20 Feet or Bumper Replacement _ 21 Hose MEMNEETT 22 Air Filter and Air Filter Cover Replacement _ 23 Dust Cover Hose Attachment Snap Replacement 24 Metal Cover Replacement _ 25 Cord Strap Replacement ___ 26 Troubleshooting 27 General System Information COMPOMEMIS POMS ENNA 28 Warranty Statement 29 x30 Returns and Repairs de keke
12. e using theHoverMatt air transfer system Transfer without the HoverMatt amp air transfer system may cause injury 12 If it is necessary to lower patient down to the floor release air by opening the uppermost 8 HJManual red deflate valve 4 When chamber 4 is fully deflated move in succession downward to fully deflate HoverJack air patient lift Caution DO NOT RELEASE ALL CHAMBERS ALL AT ONCE NEVER LEAVE PATIENT UNATTENDED ON INFLATED HOVERJACK AIR PATIENT LIFT AAAA HO V ER TECH S International RevA HOVERJACK user MANUAL Product Specifications Required Accessories Classification EQUIPMENT NOT SUITABLE FOR USE IN THE PRESENCE OF A FLAMMABLE ANESTHETIC MIXTURE WITH AIR OR WITH OXYGEN OR NITROUS OXIDE Not for use with Oxygen or Oxygen Enriched Atmospheres Type of Protection against electric shock CLASS EQUIPMENT Degree of protection against electric shock TYPE BF APPLIED PART Protection against ingress of water Ordinary not protected Mode of operation CONTINUOUS OPERATION To remove supply mains unplug equipment from wall Patient Weight Limit 1 900lbs 862kg e Use Temperature 50 to 104 F 10 to 40 C Use Humidity 10 to 70 Non Condensing e Storage Shipping Temperature 40 to 176 F 40 to 80 C Storage Shipping Humidity 10 to 70 Non Condensing Power Input 120 V 60 Hz 10 A North American version 230 V 50 Hz 6 A Australian Version Air Su
13. ection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters and electromagnetic site survey should be considered If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above the device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienting or relocating the device Over the frequency range 150 kHz to 80 MHz the field strengths should be less than 3 V m A SZ International 1 3 RevA HJManual HOVERJACK user MANUAL Electromagnetic Compatibility Chart For HTAIR 2300 ONLY Recommended separation distances between portable and mobile RF communications equipment and the HoverTech International Air Supply The HoverTech International Air Supply is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the HoverTech International Air Supply can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the HoverTech Interna
14. er issued from the company Please call 1300 365 404 for an RGA Any products returned without the necessary RGA may cause a delay in the repair time If the product is not covered under warranty a minimum charge of 100 will be assessed for each repair Should a repair charge be assessed Statina Healthcare will notify the facility and a purchase order for the repair will need to be issued before the repair can be completed Lead time for repairs is approximately 2 weeks A fee of 50 will be assessed if HoverJack air patient lift are not properly cleaned for repair All products should be sent to Statina Healthcare Australia 3 30 Leighton Place Hornsby NSW 2077 Attn Repair Dept RGA Phone 1300 365 404 Fax 02 9482 2599 8 HO V ERTECH SZ International 31 RevA HJManual STATINA HEALTHCARE AUSTRALIA 3 30 Leighton Place Hornsby NSW 2077 Phone 1300 365 404 www statina com au
15. n you over inflate the HoverJack air patient lift and cause it to burst No not if you are using the HoverTech International Air Supply The HoverJack air patient litt has been tested under conditions that would over intlate using this air supply 2 If you open the red capped valves does the HoverJack air patient lift deflate very quickly causing it to be unstable and the patient to falle Yes if you open the red capped valves all at one time However opening the redcapped valves one at a time beginning at the top chamber permits the HoverJack air patient lift to deflate rather slowly but steadily The HoverJack air patient lift remains stable when deflated properly 3 If we want the HoverJack air patient lift to lift the patient a moderate amount do all of the chambers have to be inflated for it to be stable No The HoverJack air patient lift is made to be stable regardless of how many chambers are inflated However the chambers MUST be inflated consecutively from the floor up In other words if you only want to inflate 3 chambers you must inflate chambers 1 2 amp 3 4 Will the HoverJack air patient lift raise a very heavy patient Yes The HoverJack air patient lift has been successfully tested under the weight of 1900 pounds 862 kg When lifting heavy patients extra caution must be taken to center them properly on the HoverJack air patient lift 16 EE HOVERTECH SZ International HJManual
16. nder the HoverJack air patient lift This could be a potential hazard The HoverJack air patient lift should not be laundered HoverJack Air Patient Litt Maintenance Instructions The HoverJack air patient lift should be periodically inspected to ensure the following All deflation valves are equipped with a red cap The red caps are intact All patient safety straps are attached to the HoverJack air patient lift All buckles are intact and operational Pull handles are all attached to the HoverJack air patient lift e Inflation valves are all self sealing with no evident leakage There are no punctures or tears in the HoverJack air patient lift Air Supply Cleaning and Maintenance The air supply has an air filter on either side of the motor These filters can be accessed by removing the small screws holding the filter cover in place Filters should be cleaned by hold ing under warn running water Allow to air dry As preventive maintenance filter cleaning should be performed monthly The Air Supply can be cleaned by wiping down using a damp cloth with soap and water or mild neutral detergent Dry using a clean dry cloth or disposable paper towels Do not spray cleaners or liquids directly on the air supply NOTE CHECK YOUR LOCAL STATE FEDERAL INTERNATIONAL GUIDELINES BE FORE DISPOSAL A HO VER TECH SZ International 1 5 RevA HJManual HOVERJACK user MANUAL Frequently Asked Questions 1 Ca
17. omagnetic Immunity The HoverTech International Air Supply is intended for use in the electromagnetic environment specified below The customer or the user of the HoverTech International Air Supply should ensure that it is used in such an environment IE i Immunity test k Electromagnetic environment guidance test level level Portable and mobile RF communications equipment should be used no closer to any part of the HoverTech International Air Supply including cables Conducted RF IEC 3 Vrms than the recommended separation distance 61000 4 6 150 kHz to calculated from the equation applicable to the 80 MHz frequency of the transmitter Recommended separation distance Radiated RF IEC 3 V m d 1 2 VP 61000 4 3 80 MHz to 2 5 GHz d 1 2 80 to 800 MHz d 2 3 VP 800 MHz to 2 5 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHZ and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and refl
18. ply is then used to inflate each of the four 4 chambers to litt the patient in a supine position trom the floor to the bed or stretcher height This reduces the number of caregivers needed to lift a patient while minimizing the potential of further injuries to patient and the staff The HoverJack air patient lift can be used anywhere a patient has fallen even in confined spaces such as a bathroom The friction reducing material on the bottom of the patient lift allows caregivers to easily transport the patient across any surface The HoverJack air patient litt has a weight limit of 1900 pounds 862 kg and 15 available in two widths to accommodate most patients See the HoverTech International Product Line in the General System Information section of this manual The Principle of the HoverJack Technology Recognized as the industry standard for safe patient lifting the HoverJack air patient lift allows caregivers to safely lift patients who have fallen without gathering a lift team The HoverJack air patient lift has four chambers that inflate sequentially to lift patients from the floor to bed or stretcher height in a supine position maximizing patient comfort and minimizing the risk of injury to the patient and their caregivers Once the HoverJack air patient lift is inflated the HoverMatt transfer mattress can be used with the same air supply unit for safe and easy lateral patient transfer to a bed or stretcher The Purpose of the
19. pply Dimensions 12 5 x 7 x 7 inches 31 75 x 17 8 x 17 8 cm Air Supply Weight 11 16 5 kg Air Supply Material Fire Retardant ABS Stainless Steel Power Cord Length 10 metres LESS HOVERTECH QS nternational RevA HJManual HOVERJACK user MANUAL Product Specifications Required Accessories Material Topside Material nylon oxford Underside Material Teflon impregnated polyester 32 Blam or 39 99 cm FEB ev 30 76 cm Inflated eqch chamber 7 1 2 19 cm Required Accessory HoverTech International Air Supply Part HTAIR1200 North American Version Part HTAIR2300 Australian Version All HoverTech International Products are Latex Free For a full product listing go to www statina com au 10 EE HOVERTECH SZ International HJManual Rev A HOVERJACK user MANUAL Electromagnetic Compatibility Chart For HTAIR 2300 ONLY Guidance and Manvfacturer s Declaration Electromagnetic Emissions The HoverTech International Air Supply is intended for use in the electromagnetic environment specified below The customer or the user of the HoverTech International Air Supply should ensure that it is used in such an environment Emissions Test Compliance Electromagnetic Environment Guidance The HoverTech International Air Supply uses RF energy only for its internal function Therefore RF emissions MA Group 1 its RF emissions are very low and are not likely to CISPR11 f cquse qn
20. tional Air Supply as recommended below according to the maximum output power of the communications equipment output power of m transmitter 15 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz d 3 5 V vP d 3 5 V vP d 7 E vP For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people AA SZ International 14 HJManual Rev A HOVERJACK user MANUAL Cleaning amp Maintenance HoverJack Air Patient Litt Cleaning Instructions The HoverJack air patient lift is constructed of nylon oxford The HoverJack air patient lift may be covered with a sheet or other protective piece to help keep it clean The HoverJack air patient lift can be wiped down with phenolic disinfectants quaternaries or other similar type solutions as per hospital protocol for stretchers or pads and or bed mattresses Note If using a protective sheet while moving a patient make sure it doesn t get caught u
21. ver Hose Attachment Snap Replacement To Remove Dust Cover 1 Disconnect hose from unit See page 22 2 Lift the cover flap to remove the 3 phillips head screws that attach the dust cover 3 To replace dust cover fold in the three flexible tabs Then insert the screws one at a time starting with the top middle followed by the sides To Remove Hose Attachment Snap 1 Disconnect hose from unit See page 22 2 Remove the phillips head screw and snap Dust Cover 24 EE HOVERTECH SZ International HJManual Rev A HOVERJACK user MANUAL Metal Cover Replacement 1 Disconnect hose from unit See page 22 2 Remove the two phillips head screws on each side to detach the air filter covers Remove the air filters 3 Gently pull the damaged cover apart to allow clearance to remove it 4 Carefully re insert the new metal cover Reassemble the two filters and filter covers 5 Secure everything in place by reinserting four screws Metal Cover HOVERTECH S International 25 RevA HJManual HOVERJACK user MANUAL Cord Strap Replacement 1 Unsnap the strap and remove power cord 2 Detach the damaged cord strap by removing the screw as shown 3 Reattach strap by positioning in place and securing it with the screw provided Power Cord Strap 26 X Er International HJManual Rev A HOVERJACK user MANUAL Troubleshooting Verify AC from wall Check po
22. wer cord connections at air supply and wall Check circuit breakers Return unit for repair Return unit for repair Return unit for repair Check hose connections at air supply and mattress Check hose for rips tears HOVE RTECH S International 27 RevA HJManual HOVERJACK user MANUAL Component Parts List HoverTech Part Number Description Hose Attachment Snap Information Labels HTA HAS Hose Attachment Snap AA HOVERTECH SZ International HJManual Rev A 28 HOVERJACK user MANUAL Warranty Statement The HoverJack air patient lift and the HoverTech International air supplies are warranted to be free from defects in materials and workmanship for 1 one year Warranty begins on date of in service by a Statina Healthcare representative or shipment date In the unlikely event that a problem arises as a result of a defect in materials or workmanship we will promptly repair your item or replace it if we feel that it cannot repaired at our expense and discretion using current models or parts performing the equivalent function upon receipt of the original item to our repair department You must pre notify Statina Healthcare Australia by phone 1300 365 404 is to be insured by you against loss during transportation and must be shipped with transportation and or broker charges prepaid Should any Hovertech International product be returned which 15 not covered under warranty there will
23. y interference in neqrby elecironic equipmeni CISPR1 1 The HoverTech International Air Supply is suitable for use in all establishments other than domestic IEC 61000 3 2 and those directly connected to the public low Voltage fluctuations voltage power supply network that supplies flicker emissions Complies buildings used for domestic purposes IEC 61000 3 3 A SZ International 1 1 RevA HJManual HOVERJACK user MANUAL For HTAIR 2300 ONLY Electromagnetic Compatibility Chart Guidance and Manufacturer s Declaration Electromagnetic Immunity The HoverTech International Air Supply is intended for use in the electromagnetic environment specified below The customer or the user of the HoverTech International Air Supply should ensure that it is used in such an environment IEC 60601 Test Electromagnetic Environment Immunity Test Compliance Level Level Guidance Electrostatic Discharge ESD IEC 61000 4 2 Electrical fast Transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Power Frequency 50 60 Hz magnetic field IEC 61000 4 8 6 kV contact 8kV air 2 kV for power supply lines kV for input output lines kV line s to line s 2 kV line s to earth lt 5 gt 95 dip in U For 0 5 cycle 40 60 dip U For 5 cycles 7