PSU-2T - User manual

image

Contents

1. RPM W Run Stop Fig 1 Control panel Page 7 4 7 4 8 4 9 4 10 4 11 Page 8 After the set time expires platform shaking will stop and the set working time will be shown on the display The shaker can be stopped before the set time elapses if necessary by pressing the Run Stop key fig 1 5 For 2 s the display will be showing the time the shaker has worked and after that the set time If the working time is not set and the display shows 0 00 pressing the Run Stop key will start time count up and will cause the shaker to operate non stop until the Run Stop key is pressed The timer will be counting up until 99 hrs 59 min and then will restart from 0 00 After finishing the operation turn the Power switch into Off position Disconnect the external power supply unit from electric circuit 5 Specifications The unit is designed for operation in cold rooms incubators and closed laboratory rooms at ambient temperature from 4 C to 40 C in a non condensing atmosphere and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 1 Speed control range 150 1200 rpm 150 1000 rpm using the platform IPP 4 5 2 Orbit ii WA danga eww eee u add bedas dhe ened 2mm 5 3 Digital time setting 1 min 24 hr non stop 5 4 Maximum continuous operation time 168 hrs 5
2. e Disconnect the unit from the electric circuit before moving e Turn off the unit by disconnecting the external power supply from the power socket e If liquid penetrates into the unit disconnect it from the external power supply unit and have it checked by a repair and maintenance technician e Do not operate the unit in premises where condensation can form Operating conditions of the unit are defined in section 5 Specifications Page 3 DURING OPERATION e Donotimpede the platform motion e Do not operate the unit in environments with aggressive or explosive chemical mixtures Please contact manufacturer for possible operation of the unitin specific atmospheres e Donot operate the unit ifitis faulty or has been installed incorrectly e Donotuse outside laboratory rooms e Do not place a load exceeding the maximum load value mentioned in the Specifications section of this Manual BIOLOGICAL SAFETY e It is the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment Page 4 2 General Information PSU 2T Mini shaker provides regulated shaking for two or four 96 well microtest plates It is a compact instrument with low profile and small footprint for personal application including immunoassays and colouration tests The current upgraded model provides reliable continuous operation and smooth platform motion at lower speed Non stop mode up to 7 da
3. 5 Maximum IA IIIA AUWA 0 3 kg 5 6 Dimensions aaa wa ees 220x205x90 mm 5 7 Input current power consumption 12V 280mA 3 4W 5 8 External power supply in AC 100 240V 50 60Hz out DC 12V 5 9 WEIGH ii end ne ae heed a nen ind Ea ead nd end 2 0 kg Accurate within 10 Optional accessories Description Catalogue number IPP 4 platform for 4 microtest plates BS 010102 AK dimensions 266x170 mm Replacement parts Description Catalogue number IPP 2 platform for 2 microtest plates BS 010102 BK dimensions 184x132 mm Biosan is committed to a continuous programme of improvement and reserves the right to alter design and specifications of the equipment without additional notice Page 9 6 1 6 2 6 3 CA KZI 7 3 7 4 Maintenance If the unit requires maintenance disconnect the unit from the mains and contact Biosan or your local Biosan representative Itis allowed to perform the maintenance and all types of repair operations only to the persons who have completed special training Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit Warranty and Claims The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions The warranted service life of the unit fr
4. to the movable base by inserting the pins on the underside of the platform into the holes on the supporting platform on the shaker Page 6 4 1 4 2 4 3 4 4 4 5 4 6 Operation Connectthe external power supply to electric circuit Place the microtest plates on the platform and fix them with the two screws Using the IPP 4 platform fix the microtest plates with the special holder by pressing it against the microtest plates with two screws Turn the Power switch fig 1 1 into On position located on the front panel of Shaker the display fig 1 3 will light In standby mode the display shows set time or set speed when RPM key is pressed In run mode the display shows operation time or actual speed when RPM key is pressed Using the A and W keys fig 1 4 set the operation time using the display readings The set time is indicated on the display in hours and minutes hh mm Set the shaking speed with the Speed knob fig 1 6 using set speed readings on the display Speed readings are indicated on the display while the Speed knob is being turned Press the Run Stop key fig 1 2 The platform will start shaking and the timer will start counting up the operation time The display shows actual time till 1 hour in minutes and seconds mmiss after 1 hour in hours and minutes hh mm Press and hold the PRM key while platform is shaking to display the actual speed of the platform motion on the display
5. D Medical Biological Research amp Technologies PSU 2T Mini Shaker for immunology rg Ty aK d N naan Min a ma ae ae es ane ies Was a SE me re eee ae i Se Re eee wa wa gt 3 OR Operating Manual for version Certificate V 2AW Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims Oo Noah wn Declaration of Conformity Page 2 1 Safety Precautions The following symbols mean Caution Make sure you have fully read and understood the present A Manual before using the equipment Please pay special attention to sections marked by this symbol GENERAL SAFETY e Use only as specified in the Operating Instructions provided e The unit should be saved from shocks or falling e The unit must be stored and transported in a horizontal position see package label e After transportation or storage keep the unit under room temperature for 2 3 hrs before connecting it to the electric circuit e Use only cleaning and decontamination methods recommended by the manufacturer e Do not make modifications to the design of the unit ELECTRICAL SAFETY e Connect only to an external power supply unit with voltage corresponding to that on the serial number label e Use only the external power supply unit provided with this product e Ensure that the power switch and external power supply unit are easily accessible during use
6. etlana Bankovska Aleksandr Shevchik Managing director Engineer of R amp D 1 O6 2OIS Date Version 2 03 March 2014 How to choose a proper Shaker Rocker Vortex ES 20 60 with heating Applications Microbiology Extraction Cell growing 7 ES 20 with heating is Volume of liguids 103 10 ml Erlenmeyer flasks Cultivation flasks and 50 ml tubes Medical Biological Research amp Technologies Multi Bio RS 24 Applications Microbiology Extraction aa AI Cell growing PST 60HL PST 100HL WA with heating 4 PST 60HL 4 i with heating e a va ese k Applications ELISA analysis PSU 2T Hybridization Applications DNA analysis Genome sequence MPS 3500 tw MR 1 sii H pne mmm Applications Agglutination am gt TS 100 with heating Extraction Corr TS 100C with heating Gel staining and cooling destaining Multi Bio 3D E en Applications 3 ay Agglutination ad ae Extraction VEC aie Blot hybridisation O e Gel staining destaining di J a a D AI a 10 ml 10 10 ml Petri dishes vacutainers PCR plates microtest plates and tubes up to 15 ml and Eppendorf type tubes www biosan lv Biosan Sia Ratsupites 7 build 2 Riga LV 1067 Latvia Phone 371 674 261 37 Fax 371 674 281 01 E mail marketing biosan lv
7. om the date of its delivery to the Customer is 24 months Contact to your local distributor to check availability of extended warranty If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the local distributor address Please visit www biosan lv Technical support section to obtain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete and retain for your records Model PSU 2T Mini Shaker for immunology Serial Number Date of sale Page 10 8 Declaration of Conformity Declaration of Conformity Equipment name PSU 2T Type of equipment Mini Shaker EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC WEEE 2002 96 EC amp 2012 19 EU Directive Manufacturer SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia Applied Standards EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements General requirements EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61010 2 051 Particular requirements for laboratory equipment for mixing and stirring We declare that this product conforms to the requirements of the above Directive s PUA a Ce Signature Signature Sv
8. ys and over 2 years of trouble free operation are guaranteed due to direct drive mecha nism and brushless motor PSU 2T Mini shaker provides e Gentle shaking of samples e Smooth regulation and stabilization of rotation speed e Evenshaking amplitude throughout shaker platform e Setting and indication of the necessary working time e Automatic stop of platform movement after the set time expires e Indication of the current operation time The unit is applicable in all the areas of the medicine biotechnology and microbiology laboratory research Page 5 3 Getting started 3 1 Unpacking Remove packing materials carefully and retain them for future shipment or storage of the unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage 3 2 Complete set Package contents Standard set PSU 2T Mini Shaker for immunology with IPP 2 platform 0 1 piece external power supplyunit 1 piece Operating Manual Certificate 1 copy Optional accessories additional IPP 4 platform for 4 immunoplates on request o e PRU POTTER ii kue WA TE a EPPES 3 3 Setup place the unit on the horizontal even working surface remove protective film from the display plug the external power supply unit into the 12 V socket at the rear side of the unit 3 4 Platform installation Install the platform