1. Power Supply External Power Cartridge The AirSep POC External Power Cartridge is designed to supply power to the Focus FreeStyle and FreeStyle 5 portable concentrators The external power cartridge will extend the duration of the unit when being used away from an AC or DC power source External Battery Charger Manual 5 Charging the External Power Cartridge The AirSep POC External Power Cartridge can only be charged by its external charger The 2 dock charger allows 2 batteries to be charged simultaneously from an AC power source note NOTE FOR USE ONLY with AirSep s Portable Oxygen Concentrators POCs models Focus FreeStyle and FreeStyle 5 NOTE The External Power Cartridge does not need to be fully discharged before recharging It is recommended to re charge after each use CAUTION Use only the external charger oan to charge the External Power Cartridge CAUTION Use only the universal power supply supplied with the external charger to connect it to AC power CAUTION Failure to follow these instructions may result in damage to your external power cartridge external charger or power supply and can result in severe bodily injury or prop erty damage Power Power Supply Cartridge Connector Dock 1 Disconnect the external power cartridge from the Focus FreeStyle or FreeStyle 5 if still connected 2 Connect the AC Power cord to the universal power supply if not already c
2. coil cord connector into the inlet of the FreeStyle Take note of the D shaped plug of both the coil cord and the inlet connection on the FreeStyle Once they are properly 4 To disconnect the external power aligned push inward toward the cartridge from the Focus gently pull the FreeStyle to lock the connection in place connector upward away from the top of the Focus 3 To disconnect the external power cartridge press the release button on the top of the connector and pull outward 8 MN189 1A Using the External Power Cartridge The external power cartridge has a FreeStyle 5 integrated belt clip that all it to b a er cage ine aanioe NOTE When used with the FreeStyle or FreeStyle worn on a the waist for portable use The lal J 5 if the internal battery fully depletes and the new FreeStyle bag will also accommodate Freestyle or FreeStyle 5 shuts down the unit the external power cartridge The power cannot be restarted with the External Power Car cartridge will fit in the side pocket s while _ tridge Should this occur connect your FreeStyle connected to the concentrator and in use or FreeStyle 5 to an AC DC power supply for a hb p h short period of time in order to provide sufficient Each battery has a test gauge on top wit internal power cartridge power to start the unit 4 lights representing the level of battery The External Power Cartridge can then be used for from 25 to 100 charge Pressing the test additi
3. your amp r contact your equipment provider or local home care provider for proper disposal government agency for disposal requirements You can also contact your local city or town The Battery must not be incinerated offices for instruction on proper disposal of the battery Local Environments laws may prohibit ARRERA eD disposal of electrical and or electronic equipment such as the External Battery Charger Contact local city or town offices for instructions on proper disposal of electrical or electronic equipment Alternately CAIRE Inc may be contacted for disposal information 10 MN189 1 A Notes External Battery Charger Manual 11 ul AirSep 401 Creekside Drive Buffalo NY 14228 2075 1 800 874 0202 Worldwide www CAlREmedical com Medical Product Services GmbH MPS Borngasse 20 35619 Braunfels Germany Tel 49 0 6442 962073 E mail info mps gmbh eu LF CAIRE A Chart Industries Company AirSep SeQual Chart Industries 2014 CAIRE Inc reserves the right to discontinue its products or change the prices materials equipment quality descriptions specifications and or ITI Hil II processes to its products at any time without prior notice and with no further obligation or consequence All rights not expressly stated herein are reserved by us as applicable PN MN189 1 Rev A
4. AirSep External Power Cartridge amp Charger Instructions for Use LZ CAIRE A Chart Industries Company AirSep SeQual Contents Definition of Symbols csssccsssesesssseeessseeesseeeenseeeenss 4 SE CII CAU ONS sa cccaguteccueseesenetzaniveueecspaccedevepacetiensibtecsntsacstuerartuce 5 External Power Cartridge ccssccssssessseeeesssesesseeeesseneess 5 Charging the External Power Cartridge csssseseeees 6 Connecting the External Power Cartridge sssccsssseees 8 Using the External Power Cartridge csssscssseeeesseereens 9 Equipment Disposall ccssscccsssseeseessssesseeesssseeeeeeeseness 10 a a E E E A E 11 Important Safety Instructions are defined as follows WARNING Describes a hazard or unsafe practice that if not avoided can result in severe bodily injury death or property damage CAUTION Describes a hazard or unsafe Soro practice that if not avoided can result in minor bodily injury or property damage WA Note Information needing special attention NOTE 2 MN189 1A WARNING Electrical shock hazard Turn fame OFF the unit and disconnect the power cord from the electrical outlet before you clean the unit to prevent accidental electrical shock and burn hazard Only your Equipment Provider or a qualified service technician should remove the covers or service the unit WARNING Care should be taken to prevent the external battery
5. Cartridge charger or power supply Only your Equip ment Provider or qualified technician should service the unit CAUTION ONLY USE the Manufacturer s mon provided external power cartridge and accessories For proper disposal contact your Equipment Provider or your local government agency for disposal requirements The external power cartridge must not be incinerated CAUTION Use only the external charger to charge the External Power Cartridge CAUTION Use only the universal power supply supplied with the external power charger to connect it to AC power CAUTION Failure to follow these instructions may result in damage to your external power cartridge external charger or power supply and can result in severe bodily injury or prop erty damage NOTE To prevent a void warranty follow all manufacturers instructions NOTE FOR USE ONLY with AirSep s Portable Oxygen Concentrators POCs models Focus FreeStyle and FreeStyle 5 NOTE NOTE Refer to the Patient Manual of your porta ble oxygen concentrator POC for instructions on its operation This manual only covers the use of the External POC Power Cartridge as an accessory for extended duration NOTE The manufacturer recommends fully charging the battery before first use NOTE Depending on the temperature of the power cartridge it can take several minutes for the charging cycle to begin after connecting to power This is a normal condition and is intended
6. charger power supply and external power cartridge from getting wet or allowing fluids to enter the unit s This can cause a malfunction or shut down and cause an increased risk for electrical shock or burns WARNING Use only electrical voltage speci fied on the specification label affixed to the device WARNING Do not use extension cords with this unit or connect too many plugs into the same electrical outlet The use of extension cords could adversely affect the performance of the device Too many plugs into one outlet can result in an overload to the electrical pan el causing the breaker fuse to activate or fire if the breaker or fuse fails to operate WARNING Incorrect use of the External Power Cartridge can cause the External Power Car tridge to get hot ignite and can cause serious injury Be sure not to pierce strike step on or drop the External Power Cartridge or other wise subject the External Power Cartridge to strong impacts or shocks WARNING The use of a damaged external power cartridge may cause personal injury DO NOT expose the external power cartridge to fire or dispose of in a fire This may cause the battery to explode and cause potential injury WARNING DO NOT short circuit the external power cartridge s metal contacts with metallic objects such as keys or coins This may cause Sparks or excessive heat to be generated WARNING There are no user serviceable parts Do not open External Power
7. for safe charging NOTE The External Power Cartridge does not need to be fully discharged before recharging It is recommended to re charge after each use NOTE If air travel is in your future plans it is recommended you contact your air carrier for 02 operation and limitations NOTE Clean battery charger and power supply with a damp lint free cloth and mild dish soap Do not submerge direct rinse or place in any water fluid or cleaning agent External Battery Charger Manual 3 Definition No liquids This device complies with the requirements of Directive 93 42 EEC concerning medical devices It therefore bears the CE marking as shown Definition Read user manual before operation See user manual for instructions n 2E ef o oN N Recycle Symbol This symbol is to remind the equipment owners to return it to a recycling facility at the end of its life per Waste Electrical and Electronic Equipment WEEE Directive Drip Proof Equipment IPX1 Protection against the harmful effects of the ingress of liquids Name and address of manufacturer Date of manufacturer Authorized representative in the European Community Catalog Number For indoor use only Keep unit and accessories dry Serial Number Safety Agency UL listed MH29443 JJ a v Mm gt lt a TI m 4 MN189 1 A Specifications External Power Cartridge 20 C 20 C 4 C 68 F Charger
8. onal runtime button will display the remaining charge on the battery Duration of Fully Charged Internal Battery External Power Cartridge 1 Press the round TEST button on top of the cartridge to ensure a sufficient charge before use When the TEST button is pressed the LED lights will illuminate to indicate the level of power cartridge charge 3 The concentrator s audible alarm will sound when the charge is getting low Please reference the user s manual of your POC for information on its behavior with a low power cartridge Exchange power cartridges or seek an alternate power source when this alarm activates 2 Use the tables below to determine the duration or a full power cartridge charge for your POC and prescription setting Focus External Power Cartridge Duration FreeStyle Duration of Fully Charged Internal Battery External Power Cartridge External Battery Charger Manual 9 FAA Regulation Spare batteries must be individually pro tected to prevent short circuits by placement URSEP in the original retail packaging or by oth a erwise insulation terminals e g by taping over exposed terminals or placing each bat tery in a separate plastic bag or protective pouch and carried in carry on baggage only Plug Cap Charging Terminals Equipment Disposal Your battery is rechargeable and can be CAUTION For Proper battery disposal recycled Always return the battery to
9. onnected 6 MN189 1A 3 Locate the barrel connector on the opposite end of the universal power supply Insert it into the universal power supply connector on the back of the charger 4 Plug the universal power supply into an electrical outlet If no batteries are inserted into the charger both battery Solid Red Light No battery inserted into status LED s will illuminate red to show dock power to the charger 5 Align the connectors on the bottom of the external power cartridge with the 6 The charge will also be indicated by connections in the dock of the external the built in gauge on top of the external charging station Once the connections power cartridge The gauge has four are aligned push downward to connect lights 25 100 to indicate the level the external power cartridge to the of the charge While charging a fully charger discharged external power cartridge the A AA 43 si 4ICR19 66 2 ro woe AIRSEP ERNAL POWERCARTADGE KNIN SN R Eg 25 LED will blink until 25 capacity E Be AIT is reached The LED will then turn solid ee nn and the LED that indicated 50 will blink until 50 capacity is reached This process will continue until the power cartridge reaches its capacity 6 Once the external power cartridge is inserted into the charger it will begin charging The battery status LED on the charger in front of the external power cartridge will be illuminated to indicate the stat
10. us of the charging sequence Flashing Green Light External Power Cartridge is charging 7 An external power cartridge will fully Solid Green Light External Power charge from an empty state in 5 hours Cartridge is fully charged Flashing Red Light Charging Error External Battery Charger Manual 7 Connecting the External Power Cartridge WARNING THE EXTERNAL POWER Focus warnine CARTRIDGE MUST BE DISCONNECTED l FROM THE CHARGER DOCK FOR USE 1 Connect the end of the coil cord on the WITH AN AIRSEP PORTABLE CONCENTRATOR external power cartridge to the Focus DO NOT ATTEMPT TO USE THE EXTERNAL adaptor P N CD035 1 shown below POWER CARTRIDGE OR CONNECT IT TO THE FOCUS FREESTYLE OR FREESTYLE 5 WHILE IT IS BEING CHARGED IN THE DOCK 2 Be certain to properly align the coil cord Freestyle amp FreeStyle 5 connector into the female inlet of the _ m adaptor Take note of the D shaped plug of both the coil cord and the connector Once they are properly aligned push the coil cord into the connector to lock in place 1 Connect the end of the coil cord on the external power cartridge into the unit s power connection inlet Power Inlet Press to remove 3 Insert the male end of the connector into power cord the Focus power inlet with the arrow on the side of the connector facing outward Do not force the connector into the power inlet as it can only be inserted one direction 2 Be certain to properly align the

Download Pdf Manuals

image

Related Search

Related Contents

AV-0009-GRUW Rv000 Guia Rapida de Usuario Web aSmart aS  MICRO-OHMMETER E N G L I S H User Manual  HP Print Cartridges User's Manual  User Manual  Installazione dell`Interactivity Kit per MicroTile  Version PDF de ce document - Bulletin des bibliothèques de France    Sandberg Adapter TV-OUT 9p->Comp+S-Vid  管理者モード説明書(約1.51M)    