USER MANUAL

image

Contents

1. Order code LEDJ159 USER MANUAL Xterior 60 CW WW Safety WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION INPUT VOLTAGE OF 110 240V SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the eguipment To maintain the eguipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this eguipment are not subject to warranty Xterior 60 CW WW Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment and do not modify the equipment e Do not connect this equipment to a dimm
2. 99 Fast Dimming Mode In this mode you can set both of the Cool White LEDs and Warm White LEDs brightness individually Press the MODE button to show DIMMING Now press the ENTER button and use the UP and DOWN buttons to adjust the brightness of Cool White CW from 00 99 and press the ENTER button again to adjust the brightness of the Warm White WW LEDs from 00 99 To add flash press the ENTER button again and use the UP and DOWN buttons to set the speed from 00 99 Cool White values 00 Off 99 Full on Warm White Values 00 Off 99 Full on Flash value 00 Off 99 Fast DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the ENTER button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the 2 DMX modes 3 or 6 channel press the ENTER button again to choose the desired DMX mode by using the UP and DOWN buttons For the 2 or 5 channel DMX address information please see page 5 NOTE Once the desired settings have been selected in each of the above modes ALWAYS confirm the settings by pressing the ENTER button Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE MODE on the LCD screen Now on the master unit press the M
3. ODE button to select the desired mode and the slave units will now run in sequence with the master unit Xterior 60 CW WW DMX Programme Charts 2 channel mode DMX chart 0 255 Cool White 0 100 0 255 Warm White 0 100 5 channel mode DMX chart 0 255 Strobe slow to fast 0 255 Colour temperature macros DMX Set Up DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal Xterior 60 CW WW DMX Set up DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to add
4. er pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installati
5. n in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion En Be 3 Pin XLR socket In 2 Signa ff Bin 1 GND screen Pin 3 Signal om Pin 2 Signi R Pin 4 N Pin 3 Signal Pin 5 N C j 5 Pin XLR socket 3 Pin XLR t socket f Pin 1 GND screen Pin 1 GND screen Pin 2 Signal Pin 2 Signal Pin Pin 3 Signal Pin 4 3 Signal Ne Pin 5 N C WWW PROLIGHT CO UK
6. on or use can cause serious damage to people and property Xterior 60 CW WW Introduction Introduction Features e 60 x 3W LEDs CW 36 WW 24 e Beam angle 30 degrees e 400Hz refresh rate 0 100 dimming and variable strobe e DMX channels 2 or 5 selectable e Static colour dimming master slave and DMX modes e 4 push button menu with LCD diaplay e IP rated power in out sockets e IP rated 3 pin DMX in out sockets e Power consumption 188W e Power supply 100 240V 50 60Hz e IP rating IP 65 Dimensions 320 x 140 x 325mm e Weight 8 2Kgs 11 Overview Identification 1 Tightening Knobs 2 Bracket 3 Power in 4 DMX in 5 DMX out 6 Power out 7 Mode button 8 Enter button 9 Up button 10 Down button 11 LCD display Setup Operating Instructions The Xterior 60 CW WW is a DMX 512 controllable unit made up of high efficiency LEDs and will operate in stand alone master slave or DMX control modes Xterior 60 CW WW Operation Modes Operation modes Built in colour temperature macro mode In this mode you can choose from its 17 preset built in colour temperature colour macros Simply press the MODE button to show PRESET MODE Now press the ENTER button and use the UP and DOWN buttons to choose your desired colour temperature To add flash press the ENTER button again and use the UP and DOWN buttons to set the speed from 00 99 Flash value 00 Off
7. ress 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The Quad illuminator can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a 3 pin connector for data input output Notice e Be sure to follow figures 2 8 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 1 TA DMX 512in 3 pin XLR o DMX 03 3 pin XLR 2 DMX 02 XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration A Termination reduces signal transmission problems 2 cold 1 ground i A and interferance it is always advisable to connect a Niground 2 cold Pin 1 Ground DMX terminal resistance 120 Ohm 1 4 W between i 1 7 pin 2 DMX and pin 3 DMX of the last fixture i Pin 2 Negative 3Hot 3Hot Pin 3 Postive Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour fig 4 Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmissio