Home
INSTRUCTION MANUAL
Contents
1. 1 turn on the scale and than turn it off 2 press and hold TARE and than turn on the scale LCD will show LINE on first line CAL O flashed on the second line and AD value on the third line 3 When the AD value is stable press ZERO to calibrate ZERO after 2 or 3 seconds the second line will show 1 0000 4 Place 1kg weight on the platform and press ZERO when the stable A D value is displayed after 2 or 3 seconds the display will show 2 0000 5 Place 2kg weight on the platform and press ZERO when the stable A D value is displayed after 2 or 3 seconds the display will show3 0000 6 Place 3kg weight on the platform and press ZERO when the stable A D value is displayed after 2 or 3 seconds the display will show0 0000 and now calibration is finished 7 Turn off the power then turn on the power again place some weight on the platform to make sure whether weighing is correct if not repeat steps 1 6 Single segment calibration 1 turn on the scale and than turn it off 2 press and hold ZERO and than turn on the scale LCD will show SCALE on first line CAL O flashed on the second line and AD value on the third line 3 Press SAMPLE UNIT to select calibration unit kg or Ib 4 After the stable A D value is displayed press ZERO to calibrate ZERO after 2 or 3 seconds the second will show 0 5 Set calibration weight through input 0 to 9 and than place the calibration weight you had set Press ZE
2. scale memory UNIT WEIGHT KEY is used when setting the known unit weight data into scale in normal operation N CE KEY is used for canceling the numeric setting data or cancel the previous unit weight data O QTY SET KEY is used for the alternation of changing normal counting and quantity check operation 1 SPECIFICATIONS Model number Capacity Graduation Platter Size LCT 1500 3 3 lb 0 00011b 227x337mm LCT 3000 6 6 lb 0 0002 Ib 227x337mm LCT 7500 16 5 Ib 0 0005 Ib 227x337mm LCT 15000 33 Ib 0 001 Ib 227x337mm LCT 30000 66 lb 0 002 Ib 227x337mm LCT 50000 110 lb 0 005 Ib 227x337mm Net gross weight 4 2kg 5 1kg Package Operating Temp Standard carton 39 x 39 x15 5 cm 2Units in one box 40 X40 X 35 cm 0 40 C 32 104 F Power source Large LCD Recharge Batteries or AC DC Adapter 10 12V 500mA optional FEATURES O Auto calibration O Auto backlight Auto zero tracking Low batter indication Large square pan Stability indication O unit kg lb 6 with counting function WWW PHANTOMSCALES COM CALIBRATION When to calibrate Calibration may be required when it is initially installed if the scale is moved to a substantial distance This is necessary because the weight of a mass in one location is not necessarily the same in another location Also with time and use mechanical deviations may occur Calibration linearity calibration
3. to select activate or inactivate the function of the backlight 3 UNIT WEIGHT function when there is no weights on the platform press SAMPLE UNIT key to select the unit kg or Ib When there is something on the platform press UNIT WEIGHT key to sample unit weight memory exceed 1 000 000 pieces 1 Turn on the scale b Unit weight alarm 2 Press 0 to 9 to input the unit weight you want to save Lack of Piece Weight indicator will turn on if the averaged unit weight or set 3 Press STORE to confirm the unit weight and then the display will show unit weight is not enough for accurate counting operation Operator may use He dete een a oon 4 Press M1 to M9 within 2 seconds the third line of the display will show c Alarming by press QTY SET THE SCALE has useful check function to inform operator that the total piece es counts quantity has reached the lower limit and the upper limit desired This Unit weight transfer function is designed for packing purpose For example if the operator wish 1 Press CE to clear the memory the second line of the display will show 0 to count 1 000 pieces for every package he can set the lower limit and the upper limit as 1 000 pieces as following 1 press QTY SET enter quantity alarm menu 2 Setting quantity alarm repeat step 1 enter quantity alarm menu press ZERO key to selected selected CH on this means quantity alarm is turn on If selected CH off this m
4. RO to calibrate after the stable indicator light press ZERO key the second line of display will show 00000 and now calibration is finished 6 Turn off the power then turn on the power again place some weight on the platform to make sure whether weighing is correct if not repeat steps 1 6 P MEMORY M KEY is used when accumulation the counts data this data are memorized by pressing this key and could be accumulated up to 99 counts Q MEMORY CANCEL MC KEY is used for canceling the memorized data R TOTAL KEY is used for the alternation of changing normal counting and memory data recalling S SAMPLE UNIT Ib Kg Press the key to selected weight unit Once the unit is selected the selected unit indicate the different calibration and weighing unit II OPERATION A TARE a Reduce tare weight Place the empty container on the platter Press TARE key then the tare indicator is turned on the WEIGHT display shows Zero When remove the container from the platter after reduced the weight then the WEIGHT display shows with minus sign b Clearing the previous tare value Remove weights from the platter then press TARE key so that the Tare indicator turns off and WEIGHT display returns to Zero B SAMPLE SETTING There are two sample setting method a Number setting In case of counting the unknown unit weight Place the certain numbers of sample on the platter total weight is display in WEIGHT display Set t
5. WWW PHANTOMSCALES COM LCT COUNTING SCALE INSTRUCTION MANUAL WWW PHANTOMSCALES COM USER MANUAL LCT COUNTING SCALE I Preparation Place the scale horizontally and keep the bubble inside the bubble level aligned with the red circle See Fig 1 incorrect Correct Fig 1 Il Function Explanation A WEIGHT DISPLAY indicates the gross or net when the tare function activated weight on the platter B UNIT WEIGHT DISPLAY indicates the averaged or set unit piece weight C TOTAL DISPLAY indicates the accumulated total piece number on the platter D ZERO INDICATOR turns on when scale is in zero position E TARE INDICATOR turns on when the function is being used F LACK OF SAMPLE INDICATOR turns on when the sample number on the platter is not enough for accurate counting operation in case of number of sample setting mode G LACK OF PIECE WEIGHT INDICATOR turns on when the sample unit weight is not heavy enough for accurate counting operation H NUMERIC 0 9 KEY is used for setting numeric data for sample number sample weight or limit number of checking I DECIMAL POINT KEY is used for set the decimal position of sample weight J ZERO KEY set or re adjust the scale in correct zero position for accurate counting operation K TARE KEY reduces the gross weight on the platter box or container etc as the tare weight L SAMPLE UNIT KEY is used when setting the counted sample numbers on the platter into
6. eans quantity alarm is turn off 1 Press TOTAL to show total pieces on the third line of the display 3 Setting lower limited and upper limit repeat step 1 enter quantity 2 Press MC to show the unit which will be cleared alarm menu presses TARE key to selected when the display will show 32 Press CE te confiriicle r L 0000 L for flash press digital key input 990 then press TARE key again input lower limit is complete The display will show H 0000 H for flash press digital key input 1010 then press TARE key again input upper limit is complete 4 exit the quantity alarm menu press QTY SET key to exit the quantity alarm menu IV Function setting 1 Turn off the scale 2 press and keep UNIT WEIGHT key then turn on the scale the display will show and then b ON OFF on the first line A XX on the second line 2 Press M1 to M9 to transfer the unit weight from memory Total weight clear
7. he numbers of sample through numeric keys set numbers is showed in UNIT WEIGHT display with flickering Press the SAMPLE UNIT key UNIT WEIGHT display shows the averaged unit weight per piece and TOTAL display shows the numbers of sample b Unit weight setting In case of unit weight is already known Set the unit weight data then numbers are display with flickering in UNIT WEIGHT display Press UNIT WEIGHT key then flickering of UNIT WEIGHT display is stopped c Press CE key for cancel the previous unit weight and sample setting C ALARMING FUNCTION To avoid counting error This scale has useful alarming function to inform operator the counting error feasibility in case of sample number shortage or weight shortage of sample unit weight WWW PHANTOMSCALES COM a Sample number alarm Lack of Sample indicator will turn on if the total weight of sample is below the limit value by adding the sample piece with counting until the indicator is turned off Then set the new numbers of sample through numeric key then press SAMPLE UNIT key FREE SAMPLE FUNCTION is the same as the above scale will automatically adjust and calculate new average unit weight if operator add samples in slowly with the numbers FREE SAMPLE FUNCTION will not work if the displayed numbers and L ON OFF on the third line Press QTY SET to select activate or inactivate the function of the beep Press TARE to select auto off time Press ZERO key
Download Pdf Manuals
Related Search
Related Contents
Black Box ServSwitch DT Pro II User`s Guide - WindWorks Design Curtis FRW154 Pourquoi et comment souscrire à provenceresa duvri - lotto 2 Hurricane 500-600 Tier II Operation Manual REMS Power-Press E REMS Power-Press Copyright © All rights reserved.
Failed to retrieve file