Home
Product User Manual
Contents
1. adjust motor Power and Speed fully managed by the microprocessor The adjustment can be made within a range of 50 and 100 of the Maximum Power Nevertheless every movement has an initial surge powering the motor for 2 seconds at the maximum power even if motor power adjustment is enabled Attention You will need to repeat the teach in phase if you wish to adjust the VR1 trimmer as operation and deceleration times may be affected Obstacle detection The electronic control unit is equipped with a VR2 trimmer to adjust the Counter Power required to detect the obstacle fully managed by the microprocessor The adjustment can be made by setting a time interval between a minimum of 0 1 seconds and a maximum of 3 seconds Warning the detection of an obstacle always causes the motor to change direction during the closing phase and then take 5 seconds to Stop and to reverse for 2 seconds during the opening phase and then take 5 seconds to stop Deceleration The motor deceleration function is used on the gates to stop them from reaching their final position at a high speed in the opening and closing phases The control unit allows deceleration to be programmed for the desired points before the gates are completely open or closed during Motor Timer programming see Main menu If you are using the Automatic programming function see Extended Menu it is also possible to include a deceleration phase Warning light The c
2. that everything is installed so as to maintain the IP protection characteristics of the panel as unchanged as possible Also be sure to set up the cables so that they are firmly anchored The rear part of the casing is equipped with fittings for wall mounting it is possible to drill holes for installation with plugs or there are already holes available for installation with screws Plan and implement all necessary measures to achieve an installation that does not alter the IP protection Push button panels for manual control must be assembled by positioning the push button panel in a location where the user is not in a dangerous position For a correct functioning of the radio receiver if using one or more control units the installation at a minimum distance of at least 3 metres one from the other is recommended the products Electronic Control Unit MC16 they comply with the specifications of the Directives R amp TTE 99 5 EC EMC 2004 108 EC LVD 2006 95 EC CE Rev 1 1 of 15 01 2013
3. of the photocells The control unit by default requires the intervention of the photocells in opening to be ignored while in closing it causes a reverse movement If you want to enable the operating logic which requires the intervention of the photocells to cause the immediate shutdown of the automation in the opening and closing phases proceed as follows make sure you have enabled the Extended Menu indicated by the alternate flashing of the T RIT ANTE AP led and T RIT ANTE CH leds with the SEL key select the flashing T PAUSA LED and then press the SET key the T PAUSA LED will switch on permanently and the programming is completed Repeat the procedure if you wish to restore the previous configuration The control unit is supplied by the manufacturer with the possibility of directly selecting the main menu functions only To enable the functions listed in Extended Menu 2 proceed as follows open Extended Menu 1 as instructed in the respective section then press and hold the SET key for 5 seconds the T RIT ANTE AP and T RIT LEDs will flash at the same time you have 30 seconds to select the functions of Extended Menu 2 using the SEL and SET buttons After another 30 seconds the control unit returns to the main menu A 1 2 MOTORS Encoder OFF Encoder ON B CODE Not Used Not Used C T MOT Not Used Not Used D T PAUSA Not Used Not Used E T RIT ANTE AP simultaneously F T RIT ANTE AP simultaneously F
4. operation time of max 4 minutes The control unit is supplied by the manufacturer with a default motor operation time of 30 seconds without deceleration To modify the operation time of motors 1 and 2 proceed as follows when the gate is closed use the SEL key to navigate to T MOT when the respective LED is flashing then press the SET key briefly and Motor 1 will begin its opening cycle when the initial point of deceleration is reached press the SET key again the T MOT LED will start flashing more slowly rate and motor 1 will decelerate when the desired position is reached press the SET key to complete the opening cycle The T MOT LED now starts flashing normally again and Motor 2 will begin its opening cycle program the work time for Motor 2 following the same instructions as for Motor 1 After programming the opening times for the motors Motor 2 will start its closing cycle repeat the same instructions as above for programming the closing cycle of Motor 2 and then for Motor 1 To deactivate the deceleration function during programming once the opening and closing cycle is completed press the SET key twice in succession instead of just once If the control unit is used in the configuration with 1 Motor 1 2 MOTORS OFF Led the programming of the working time of Motor 2 is not carried out During programming the radio control key of the control unit can be used instead of the SET key if stored previously 4 T PAUSA Auto
5. the operation of an automation to 1 motor proceed as follows press the SEL key until the 1 2 MOTORS led flashes then press the SET button At the same time the 1 2 MOTORS led remains steady and the procedure is completed Repeat the procedure to restore the previous configuration In the configuration with 2 motors if motor 1 stops upon reaching the limit switch integrated in the motor itself motor 2 is also stopped by the control unit 2 CODE Radio control code The control unit can store up to 5 radio controls with different fixed or rolling codes Programming The transmission code is programmed in the following way use the SEL key to move to the flashing CODE LED at the same time send the pre selected code from the radio control you wish to use when the CODE LED stays on steadily programming is finished f you have stored 5 codes and you repeat the programming operation all the programming LEDs will start flashing to indicate that no more codes can be stored Programming a single MX14 radio device To program a single MX14 radio device capable of sending radio commands as a function of applied load repeat the above operation pressing the SEL button twice the CODE LED flashes rapidly instead of once Deletion All the stored codes are deleted as follows press the SEL button until the CODE led flashes then press the SET button and the CODE led turns off and the codes are deleted 3 T MOT Programming a motor
6. IT ANTE AP leds and T RIT ANTE CH leds with the SEL key select the flashing CODE LED and then press the SET key the CODE LED will switch on permanently and the programming is completed Repeat the procedure if you wish to restore the previous configuration C T MOT Deceleration As mentioned above it is possible to programme a deceleration phase on the control unit for the opening and closing of each motor whereas deceleration is automatically applied with the Automatic Programming function If you do not wish to implement any deceleration it can be excluded therefore if you are using Automatic Programming the Deceleration phase will not be enabled whereas if you are using Motor Time Programming as you are programming you will not be given the possibility of programming deceleration during the opening and closing phases If prior to excluding deceleration it was programmed from the Motor Time Programming function it will be necessary to repeat programming all over again If you wish to deactivate the deceleration proceed as follows make sure that you have enabled the Extended Menu indicated by the alternate flashing of the T RIT ANTE AP Led and T RIT ANTE CH led by using the SEL key select the flashing T MOT LED and then press the SET key At this point the T MOT Led lights up steady and programming is finished Repeat the operation if wanting to restore the previous configuration D T PAUSA Operating logic
7. MC16 ELECTRONIC PANEL 24Vdc electronic control unit for home automation applications with incorporated receiver TECHNICAL DATA 24Vdc 2x50 W max 24 Vdc 3 W max 24Vdc 3 W max 10 55C Motor outputs Indicator light output Power supply to photocells Working temperature Radio receiver see model Op transmitters 12 18 Bit or Rolling Code TX max codes in memory 5 Dimensions of container Container ABS V 0 IP54 110x121x47 mm TERMINAL BOARD CONNECTIONS CN1 1 Input 20Vac 5A 2 Input 20Vac 5A 3 Output 24V Motor 1 4 Output 24V Motor 1 5 Output 24V Motor 2 6 Output 24V Motor 2 CN2 1 Encoder power supply 12Vdc 2 Motor Encoder 1 Signal Input 3 Motor Encoder 2 Signal Input 4 GND Encoder Power Supply 5 Power supply to photocells 24Vac 3W 6 Power supply to photocells GND 7 Indicator light output 24Vdc 8 Common GND input 9 Safety device input NC 10 Close push button input P P NA 11 Common GND input 12 Open push button input NA 13 Aerial earth input 14 Aerial hot pole input R1 R2 FORZASVELOCITA SENSIBILITA RIT ANTE CH RIT ANTE AP PAUSA MOT ODE i2 MOTORI eT eT eT eT ec 1 SEL SET OPERATING CHARACTERISTICS Operation of the Open and Close command Buttons CGB connecting the No 6 and No 8 CN2 inpu
8. e manufacturer without door delay during closing To programme the door delay time follow this procedure with the shutter closed with the SEL key to the T RIT LED when flashing ANTE CH press the SET key wait for desired interval of time then press the SET key again the delay time of the door closing will be stored and the T RIT LED is on ANTE CH is on To restore the initial configuration without door closing delay go to the T RIT ANTE CH LED when flashing and then press the SET key twice within 2 seconds the LED goes off and the operation is completed EXTENDED MENU 1 The control unit is supplied by the manufacturer with only the option of directly selecting the functions listed in the main menu To enable the functions listed in Extended Menu 1 proceed as follows press the SET button and hold for 5 seconds the T RIT ANTE AP and T RIT ANTE CH leds will flash in alternation you have 30 seconds to select the functions of Extended Menu 1 using the SEL and SET buttons after another 30 seconds the control unit returns to the main menu DS Blocks in AP and E T RIT ANTE AP Flashing beacon ON OFF in alternation F T RIT ANTE CH Flashing beacon ON OFF in alternation Rev 1 1 of 15 01 2013 A 1 2 MOTORS AUTOMATIC Programming With this control unit it is possible to carry out Automatic Programming SIMPLIFIED First place the automation gate in an intermediate position
9. entre allows the connection of a 24Vdc Rev 1 1 of 15 01 2013 3 W max to show the state of the automation process The light is off when automation is closed and it is lit when the automation is open or in motion PROGRAMMING SEL key selects the type of function to be stored selection is indicated by a flashing LED Repeatedly press the key to select the desired function The selection remains active for 10 seconds indicated by the flashing LED after 10 seconds the control unit returns to its original status The SET key this programs the information according to the type of function previously selected with the SEL button IMPORTANT The function of the SET key can be replaced with the radio control if programmed previously CODE LED on MAIN MENU The control unit is provided by the manufacturer with the possibility of selecting a number of important functions LED Reference 1 1 2 MOTORS Automation 2 Motors Automation 1 Motor 2 CODE No code Code activated LED off LED On 4 T PAUSA No auto close With auto close T RIT ANTE AP No gate delay Programmed delay 6 T RIT ANTE CH No gate delay Programmed dela a 3 T MOT 30 sec actvity Programmed delay 5 T 1 1 2 MOTORS For ease of installation the control unit has by default two automations with 1 or 2 motors The control unit has by default the typical operation of an automation with 2 motors To enable by default
10. lashing beacon ON OFF Flashing beacon ON OFF A 1 2 MOTORS ENCODER The control unit supplied by the manufacturer can manage Motors with a point Encoder in the default configuration Encoder point control is disabled If you wish to enable the control unit proceed as follows make sure that you have enabled Extended Menu 2 indicated by the alternate flashing of the T RIT ANTE AP Led and T RIT ANTE CH Led with the SEL key position on the flashing of 1 2 motors Led then press the SET key the 1 2 MOTORS Led will simultaneously switch on permanently and the programming is completed Repeat the procedure if you wish to restore the previous configuration RESET EXTENDED MENU 2 To reset the default configuration of the control unit press the SEL and SET buttons simultaneously all RED signal Leds will switch on and then immediately off again IMPORTANT FOR THE USER The device must never be used by children or persons with reduced physical psychological abilities unless supervised or trained to operate it and instructed in its modes of use Do not allow children to play with the device and keep the radio controls away from their reach ATTENTION keep this instruction manual safe and observe the important safety requirements contained herein Failure to comply with the requirements may cause damage and serious accidents Frequently examine the system to detect any signs of damage D
11. make sure you have enabled the Extended Menu indicated by the flashing T RIT ANTE AP and T RIT ANTE CH leds use the SEL key to navigate to MOTORS 1 2 when the respective led is flashing and press the SET key continuously Motor 2 will carry out closing until the limit switch or until it stops then the operation will be repeated from Motor 1 Should the motors move in a manner contrary to that described release the SET button disconnect the power supply to the control unit and connect the motor wires correctly If the motor sequence is correct the control unit completes the Auto programming phase by executing a complete opening and closing phase hold the SET key down until Auto Programming is finished At the same time the Deceleration cycle is automatically configured at 15 of the complete cycle During Automatic Programming you can use the radio control key on the control unit instead of the SET key only if previously memorised B CODE Close Buttons Configuration The control unit by default provides for the use of buttons to No 6 and No 8 of CN2 respectively for the sole closing and opening automation However you can configure the button at No 6 as Button NA with cyclic operation open stop close while the button at No 8 continues to control the opening only If you wish to enable the deceleration proceed as follows make sure that you have enabled the Extended Menu indicated by the alternate flashing of the T R
12. matic closing time programming max 4 minutes The control unit is factory supplied without automatic closing To enable the automatic closing function proceed as follows use the SEL key to navigate to T PAUSA when the respective LED is flashing then press the SET key again briefly the automatic closing time is stored and the the T PAUSA LED remains lit constantly If you wish to restore the initial condition without automatic closing move to the flashing T PAUSA LED then press the SET key twice within 2 seconds The LED will switches off and the operation is complete When programming you can use the radio control key on the control unit instead of the SET key if stored previously 5 T RIT ANTE AP Programming door delay of 10 sec Max The control unit is supplied by the manufacturer without door delay during opening To programme the door delay time follow this procedure with the shutter closed with the SEL key to the T RIT LED when flashing ANTE AP press the SET key wait for desired interval of time then press the SET key again the delay time of the door closing will be stored and the T RIT LED is on ANTE AP is on To restore the initial configuration without door opening delay go to the T RIT ANTE AP LED when flashing then press the SET key twice within 2 seconds the LED goes off and the operation is completed 5 T RIT ANTE CH Programming door delay of 25 sec Max The control unit is supplied by th
13. o not use the device if it is in need of repair work Attention All operations which require opening the casing connecting cables programming etc must be carried out by expert personnel during installation For any additional operation that requires the casing to be re opened re programming repairs or amendments to installation contact the after sales assistance Rev 1 1 of 15 01 2013 IMPORTANT FOR THE INSTALLER The control unit does not have any type of isolating device for the 230 Vac line It is therefore the responsibility of the installer to set up an isolating device inside the system It is necessary to install an omnipolar switch surge category Ill It must be positioned to provide protection from accidental closing pursuant to point 5 2 9 of EN 12453 The various electrical components external to the control unit must be cabled in accordance with standard EN 60204 1 as amended and as set forth in point 5 2 7 of EN 12453 The power supply cables can have a maximum diameter of 14 mm the power supply and connecting cables must be set up through the assembly of cable glands supplied as optional For the power supply cables use flexible cables in an insulating sheath in harmonised polychloroprene HO5RN F with a minimum conductor section of 1mm2 Be careful when drilling holes in the outside casing to pass connecting and power supply cables through and when assembling the cable glands
14. ts of the Close and Open command buttons normally open you will have the following effect The Open button controls the opening of the gate until the motor time expires the Close button controls the closing of the gate if a control is sent in the same direction before the motor time expires the control unit stops the gate if a control is sent in the opposite direction before the motor time expires the mechanism will be reversed Operation with radio control Using the radio control will have the following effect the first command impulse activates the opening mechanism for the pre set motor operating interval The second command impulse activates the closing mechanism of the gate if a command impulse occurs before the pre set motor operating interval the mechanism stops the gate A further command will reactive the mechanism in the opposite direction Photocells The mechanism allows for power supply and the connection of Photocells Commands from the photocells is ignored during the opening and when the gate is closing they will reverse the direction of movement Encoder Motor 1 and Encoder Motor 2 The mechanism allows for the connection of the position Encoder of Motor 1 and Motor 2 In this way you can always check the exact position of the motors during each motion phase Attention Leave these inputs free if not used Motor Power and Speed adjustment The electronic control unit is equipped with a VR1 trimmer to
Download Pdf Manuals
Related Search
Related Contents
Unisense UnderWater Meter 要求水準書【修正版】(PDF:2187KB) Here User Manual PDF - Heath Consultants Grève mode d`emploi Les droits des collaborateurs de l`Etat dans le Frequently Asked Questions COSTA RICA - Comisión Económica para América Latina y el Caribe EPIR2GSM Alarm System Copyright © All rights reserved.