1. geomaris Step 2 Data Server Credentials es The public keys and or the Data Server Certificate have not been found Ifyou have received your Data Server Certificate from IHO press Import Keys Otherwise press Next to create new Data Server Keys Import Keys Import Public Key and Data Server Certificate E Import Keys Enter Data Server ID 1A Figure 3 Import or create Data Server credentials 3 4 2 2 Generate New Keys If you have no Data Server Certificate just press the Next button Step 2 Data Server Credentials New Data Server Keys BCS pub BCSSelfSignedPublicKey tt and BCSPrivateKey pqgx have been created Please make a backup copy ofthese key files to a secure location Click the link below to open the directory in the file explorer CA Users Public Documents Data Protection Suite Config Data Server Credentials The Hydrographic Data Protection Suite is currently operating in Unauthorized Data Server Mode To obtain an official Data Server Certificate send a Data Server Request together with the files BCS pub and BCSSelfSignedPublicKey tt to the International Hydrographic Bureau IHB When you receive the Data Server Certificate for your generated keys from IHB you can importitfrom the Tools menu Figure 4 New Data Server credentials created Hydrographic Data Protection Suite Page 10 Hydrographic Data Protection Suite U se r M a n u al The next
2. 38 Cells in Cell Pool The last cell data is from 23 01 2013 Filter Cell Name Product Spec Update Application Date select Ev to select Ey Issue Date Of Last Update select Ey Intended Usage Cell list EE ASES rt Cell Update US2HA03M 02 10 2012 02 10 2012 ENC 2 0 US002332 TXT US2HA05M Y 24 08 2011 24 08 2011 24 09 2012 E ENC 2 0 US002346 TXT US2HADEM 16 09 2011 16 09 2011 ENC 2 0 US003555 TXT US2HA07M 04 02 2011 04 02 2011 ENC 2 0 US003616 TXT US2HA08M 02 02 2011 02 02 2011 ENC 2 0 US003620 TXT US3HA04M 03 03 2011 03 03 2011 13 12 2011 ENC 20 US002216 TXT US3HA10M 18 04 2012 18 04 2012 02 01 2013 ENC 2 0 US002347 TXT US3HA20M 18 04 2012 18 04 2012 03 10 2012 ENC 2 0 US002358 TXT US3HA60M 26 04 2012 26 04 2012 24 10 2012 ENC 2 0 US002435 TXT US3HA76M 20 10 2011 20 10 2011 ENC 2 0 US003635 TXT US4HA14M 25 09 2012 25 09 2012 27 12 2012 ENC 2 0 US002250 TXT US4HA23M 17 04 2012 17 04 2012 21 12 2012 6 ENC 2 0 US002329 TXT US4HA30M 18 04 2012 18 04 2012 13 11 2012 6 ENC 2 0 US002337 TXT SOU Cell Pool Directory C Users Public Documents Data Protection Suite Cell Pool Figure 17 The updated table displaying the Cell Pool content Now that the Cell Pool is populated with some data an Exchange Set CD can be defined 4 2 2 Manage Exchange Set CD Definitions The Exchange Set CD Definitions tab page on the Man
3. ooocconcccoccconcccoccconcnconcnonanconcnnnnos 41 Figure 42 The empty Customer Systems overview table oocccooccccocccccncccnoncnnnns 42 Figure 43 Customer System 7l ooccccnccncnncnncncnnonocnncnnnnnonnnonnnnnnnnnnonnrnnnnnnnonnnnnnnnnnnennnnnos 42 Figure 44 Customer System 2 tectssessenascdnacscadtzcnsabeaedudneadoncaerenieedemdanetecneanenand 43 Figure 45 Two Customer Systems in the overview table cccsececseeeeeseeeeeeeeeeees 43 Figure 46 Create a Group for a ship and add the Systems on the ship 44 Figure 47 Double click or the Edit button opens the group for editing 45 Figure 48 Selecting Member Groups ccooccccoccnccccnccncnnconcnonncononncnnoncnononnnonannnnnnnnnoncnnnos 45 Figure 49 Add group MS Great Adventure to Caribbean Dream Cruise Ships 46 Figure 50 Lease detail with two systems occoccccccnccccnnncnccncnnnononnnnnoncnnnnncnncnnnnnnoncnonons 47 Figure 51 Create Cell Permits tab pagQe ccccoccnccccncccccncconnnonnnnnnncnonnnnnonanncnnnnononcnonos 48 Figure 52 Confirm Cell Permit Creation cccccccccsecceceeeeceeeeeseeeeseeeeeseeeeseeeesseeesees 48 Figure 53 Cell Permit Creation Summary coccccoccnccncnnccnnnnnnnnnnnnnnonncnnnnnnnnnnnnnnnnnnnonnnonos 49 Figure 54 The output directory contains one directory for each system 49 Figure 55 Cell Perm File e dccdsccehecscecadactendsdactsadeda
4. Prod Cell Name Status Ms US3HA10M us3Ha2om US3HASOM Y US3HA76M US4HATAM USAHAZ3M o 9 9 Cell Pool Directory C Users Public Documents Data Protection SuiteiCell Pool Figure 26 Updated Cell Pool containing US1HA01M and US2HA05M 004 Hydrographic Data Protection Suite Page 29 Hydrographic Data Protection Suite U se r M a n u a 1 Exchange Set CD Definitions 0 records with Exchange set list N There are changes in the cell pool for this exchange set Output Directory C Users Public Documents Data Protection SuitelEx Set Build O dialog provides the options to build a BASE Exchange Set CD or an UPDATE Exchange Set CD as shown in Figure 28 The input data in the cell pool and the README TAT content must be up to date 29 is shown after POMBE Hydrographic Data Protection Suite Page 30 Hydrographic Data Protection Suite User Man ual Es Exchange Set Build Summary Exchange Set CD CD 1 Hawaii Complete UPDATE WK11 14 successfully created C Users Public Documents Data Protection SultelExcha Set Build Output Hawai Complete O 1 Hawai Complete UPDATE Wk 1 14 Click to open Build Log ESO d a Dataset US2HA03M No new items to add no Li No new updates available DT TT OO i 5 57 update cell US2HA405M 004 successfully compressed and encrypted signature file created no i
5. erram 13 Enter license request information cccceeccseeceeceeeeeeeeeeeeseeeaeeeaeeeaeeeaeeeaaes 14 License Request File lrq generated erre 14 Send the license request to register MgeomariS COM ccceeeeeeeeeeeeees 15 AMPON AMC CONS SMS a nesta gas na 16 Wizard config ration INISNCO sesion 17 SS A O Ri RR eo aan 18 Empty cell pool table ooocccoccococncoccocconocncnonanononnnoncnonnnonnncnnrnonanonns 19 Cell Data Files for US2HA0O5M ooccccocccccccconcncccnncncnconcncnnnnnnnnnonnnnnnnnnnnnnnanonos 20 Hawaii Cell Directories in the Cell Pool Directory ccconccconccccoccnconcnnonos 21 The updated table displaying the Cell Pool content ccooccccocncccccncno 22 Add a New Exchange Set CD DefinitiON coooccconcccconcnconcncnnnnnnoncncnnoos 23 Enter new Exchange Set CD Definition cccoccccoocncccccnconnncconnnonacncnnons 24 Cell Selector Form Add all cells to Exchange Set CD Definition 24 Enter an Exchange Set CD DefinitiON coooccccoccnccocnccccnnconcnononnnonacononons 25 Figure 22 The new Exchange Set CD Definition was not built yet ooo 26 Figure 23 Confirm Exchange Set CD Build dialog erre 27 Figure 24 Exchange Set CD Build Summary form erraram 27 Figure 25 The Exchange Set CD deliverables erraram 28 Figure 26 Updated Cell Pool
6. Added 0 supplemental files 6 are already part of last base exchange set X Date USADO No emo OO no Li No new updates available Xan USA no ewtomt _ Hore Dataset USADO No Remato OOOO MIC O Date USADA No emo OOO E la Figure 29 Build summary of the Update Exchange Set CD build The UPDATE Exchange Set CD only contains the cells and updates not yet shipped with the last BASE Exchange Set CD This leads to lower data volume for transfer via network Hydrographic Data Protection Suite Page 31 Hydrographic Data Protection Suite User Man ual 4 3 Grant Access In order to grant access to S 63 encrypted data the Data Server creates Cell Permits for the Customer Systems Each Cell Permitis valid for one cell to be used on one particular system and has an expiry date S 63 compliant systems read Cell Permits from a text file named PERMIT TXT To help users manage the configuration of customers systems data selections and leases efficiently and concisely the Hydrographic Data Protection Suite provides the possibility to create named groups of systems Groups of Systems and named groups of datasets Cell Packages A Lease grants a number of Customer Systems specified by a list of Systems and a list of Groups access to a number of Cell Packages The Lease additionally defines the scheme to determine the expiry date for each Cell Permit created as part of the Lease A Lease can be thought of as an agreement with a
7. Open the Enter Expiry Date s dialog o ccooccccoocncnonccconcncononononcnnnns 62 Figure 71 Editing the Cell Expiry Date Scheme oocccocccccccccccccnccncncnonnnonacncononononcnnnos 63 Hydrographic Data Protection Suite Page 67 Hydrographic Data Protection Suite User Man ual 5 5 Index AMIA tae Tas rod SD a doada aes 51 BASE Exchahce SUCOS anios 27 SUK GY ARRENDAR E RSRS RISO PANA IRADO RO 56 Co PACRABO acoso sda 7 32 Ce TPS A esos ceutecotcesesagsateeacsasssanoeetstecesenasiaossceicosas RS SR NDA PR 32 47 Cel Permitf EXPY SCHON enciendo rios epa 38 60 61 COMP ileso PRESS E RS DADO PS 32 47 cs RIR RAD RD RR SER CEU PERNA PRE DONE RE 19 CEIP OODE OTY aene E E EE PA RAR 20 CUSTOMISE yole eE E E EE 7 32 41 DEIA eo y AAA EA AA E E EES 7 Data SCI asirio 5 Data Server CON ITICALO soso E ndanaaS asda dessa soa asi ssa das ass 9 51 D ta Server AMM A inca din Ancara Ds nda o T sm a canina das 9 Exchange Set CD Definitio Aisiiencsctenecssiesnccesncnaieetenameassewdoanussersauencontienecanannsuudeiivosevaansescssatessuaners 7 22 Exchange Set CD NUMDET Sendas nad dnain Ds Naa ooo a dra ie saia Ga siendo 55 FIO GD ALCS OP e O PEPE 0 0 o 39 Generate ROS A o a e PE F ES E In 10 WOUD Rn RR RR A PP OU SR TRE PNR S 7 SPOOF SY SU E o o CO A o QU 35 IMPONE ro air 9 Initial Configuration Wizard ccccooccnnconncnnnonanonnnnnnonnnonaconnonanonnnnnnrnnnnnnorononanonnnnnnrnnnonnrrnnonancnnnnnnoss 8 A A RP A 7 A A A A EEE 7
8. The Protect Data button opens the Manage Cells and Exchange Set CDs form for performing all actions related to encrypting cell data and building Exchange Set CDs These tasks are covered in detail in section PROTECT DATA The Grant Access button opens the Manage Systems Groups and Leases form The form provides access to all functionality related to creating Cell Permits for Customer Systems These tasks are covered in detail in section GRANT ACCESS The Tools menu provides access to the SETTINGS dialog and some special ADMINISTRATIVE TASKS ES Data Protection Suite File Tools Help Data Server Information Data Server Burgham Chart Service BCS 0 CDs in service Exchange Sets Protect Data No exchange set was built yet Grant Access D Systems O leases and O packages in database Figure 13 The Main Window 4 2 Protect Data The Hydrographic Data Protection Suite reads all the cells it includes into S 63 Exchange Set CDs from a directory called the Cell Pool Directory Multiple Exchange Set CDs can be defined each comprised of a specific subset of the Cell Pool cells Hydrographic Data Protection Suite Page 18 Hydrographic X Dots Protection Suite User Man ual A CD number is assigned to each Exchange Set Definition in the Data Server s service as demanded by the S 63 standard In this document the terms Exchange Set CD and Exchange Set CD Definition are used instead of the simplified term Exchange Set used m
9. created 5 days ago Skipped WD Last cell key for cell US2HAQ8M created 5 days ago Skipped Last cell key for cell US3HA04M created 5 days ago Skipped O Last cell key for cell US3HA10M created 8 days ago Replaced with new cell key G Last cell key for cell US3HA20M created days ago Replaced with new cell key Last cell key for cell US3HAGOM created 8 days ago Replaced with new cell key i Last cell key for cell US3HA76M created 8 days ago Replaced with new cell key i Last cell key for cell US4HA14M created 8 days ago Replaced with new cell key 11 Last cell key for cell US4HA23M created 8 days ago Replaced with new cell key o Last cell key for cell US4HA30M created 8 days ago Replaced with new cell key Last cell key for cell US4HA51M created 8 days ago Replaced with new cell key i Last cell key for cell US4HA61M created 8 days ago Replaced with new cell key Figure 64 Cell Key Generation Log Hydrographic Data Protection Suite Page 58 Hydrographic Data Protection Suite U se r M a n u al 4 5 Settings The Settings form opened from the main window s Tools menu provides two tabs The Label replacement tab Figure 65 allows entering custom labels replacing the labels for the remark fields The Misc tab Figure 66 allows setting certain default values Label replacement Misc Customer Systems remark label replacement
10. 12 2013 12 52 11 12 2013 12 52 File MM Computer amp Local Disk C gt Local Disk D gt 4 m 2 items selected Date modified 11 12 2013 12 52 Size 1 27 KB Figure 57 The Certificate and Public Key file ready for import If the Data Server Certificate and public key were successfully validated the user must enter the Data Server ID a two letter alphanumeric identifier The Data Server ID is assigned to organizations by the IHO and is submitted to together with the Data Server Certificate Figure 58 shows the Import Data Server Certificate form Es Import Data Server Certificate Import certificate Import Data Server Certificate Status Data Server Certificate is valid Data Server ID Enter Data Server ID Figure 58 The Import Data Server Certificate dialog after successful validation Note The 11 shown as Data Server ID on the screenshot is just an example and may not be used for an installation After pressing Ok the Unauthorized Data Server Mode indicator is removed from the main window title The Hydrographic Data Protection Suite now produces Exchange Set CDs recognized as originating from an IHO accredited Data Server by S 63 compliant systems Hydrographic Data Protection Suite Page 52 Hydrographic Data Protection Suite User Man ual 4 4 2 Import Manufacturer Key List IHO accredited Data Servers frequently receive an update Manufacturer Key list in a pa
11. Favorites EE Desktop MS Great A a CA J Downloads aa 13 03 2014 16 56 Recent Places Figure 54 The output directory contains one directory for each system Figure 54 illustrates the directory structure for the created Cell Permit Files One directory is created for each Customer System Hydrographic Data Protection Suite Page 49 Hydrographic Data Protection Suite User Man ual The content of one of the generated Cell Permit files is shown in Figure 55 each line represents one Cell Permit PERMIT TXT Notepad File Edit Format View Help DATE 20140313 16 40 VERSION 2 ENC US5HAL12M20140408F 919D150C 41 SEACSF919D150CA1 3E4C5C551654D7D479D2E 0 DM US5HAL M2014 04 080E8F D3 3A84 21 2 F1D0E8FD353484 21 2 F1D6044 F8C3 08C1EB 0 DM US5HA2 2M20140408652781 5544 4EF 4156527815544 4EF 41 5636B3E0D22FF7908 0 DM 155H455M201404082804D2DCFE51FE132804D2DCFE51FE1369F8100C24036FA40 0 DM US5HA63M20140408E4F91793997460 0 4F91793997460C053B0F42B6EA9CE89 10 DM EC Figure 55 Cell Permit File Note The cell names first 8 characters and expiry dates next 8 characters are readable which allows to programmatically detect if any new or longer lasting cell permits exist in comparison with the last Cell Permit file version sent to the customer Hydrographic Data Protection Suite Page 50 Hydrographic X Data Protection Suite User Man ual 4 4 Administrative Tasks 4 4 1 Import
12. Piked Lime interval 61 AMD WICC O UR RE DER O RR OO TI oasdeueduandiateasees 61 5 ANNE A GREGO DRE RR En BERRO OR A RAD PEA E E 64 Dedo es A e O o E E O A E 64 e AOS arar 64 A e PE BO UE GO II nuke Rasa ssa cd atas erigida 66 A 66 A a gt PROTO RR PR RD bases RR RP IR E DO RR RR UR 68 Hydrographic Data Protection Suite Page iii Hydrographic Data Protection Suite User Man ual 1 Introduction 1 1 Purpose This user manual is intended for users and administrators who install configure and operate the Hydrographic Data Protection Suite version 1 0 1 2 Conventions Throughout this user manual the following conventions are used Note To specify something that should be taking into account Warning To alert about something that could produce an undesirable effect REFERENCE A cross reference to another part of the document Some Central Glossary Terms start with capital letters and are presented in italics Button text refers to a button on a form 1 3 Contacts For getting assistance or reporting an error please contact support geomaris com For better assistance please have at hand the following information e Context in which the problem is occurring e Error message and detailed problem description Hydrographic Data Protection Suite Page 4 Hydrographic Data Protection Suite User Man ual 2 Overview 2 1 The S 63 Data Server Role The S 63 Data Protection Scheme operated by the In
13. Step 1 Enter Data Server Name e Name ofthe Data Server Example Test Data Server Ltd y Burgham Chart Service Acronym or Short Name Example TDS BCS Figure 2 Enter a Data Server name 3 4 2 Step 2 Data Server Credentials The Data Server needs a private key a public key and a Data Server Certificate to sign encrypted ENC cell files At this step you have two choices 3 4 2 1 Import Keys If you already have received a Data Server Certificate trom IHO you can import it along with the public key from a directory of your choice Press the Import button on the wizard page and select the Data Server Certificate file certificate for import The public key file pubk must reside in the same directory and will be automatically imported Figure 3 Note The software assumes that the IHO Data Server Certificate file is named certificate and the public key file is stored in the same directory and is named pubk If your certificate and public key files are named differently you must rename them first lf the Data Server Certificate and public key were successfully validated you must enter the Data Server ID a two letter alohanumeric identifier assigned to organizations acting as Data Server by the IHO The Data Server ID has been submitted to your organization together with the Data Server Certificate Hydrographic Data Protection Suite Page 9 Hydrographic Data Protection Suite User Man ual
14. System 1 User permi 34D469828E404189670512EE3231 Figure 43 Customer System 1 Hydrographic Data Protection Suite Page 42 Hydrographic Data Protection Suite U se r M a n u a Enter new System Name MS Great Adventure System 2 User permit BCFFIE349E126664231040163334 Figure 44 Customer System 2 Figure 45 shows the Customer Systems overview table with the two entries last creation time 13 03 2014 13 39 02 last modification time 13 03 2014 13 39 02 Filter Name Creation time select Ev to select Br Modification time select Figure 45 Two Customer Systems in the overview table For good maintainability the Customer Systems are not directly added to the Caribbean Dream Cruise Ships group Instead a Group of Systems is created for the MS Great Adventure and the two example systems are added Figure 46 Hydrographic Data Protection Suite Page 43 Hydrographic Data Protection Suite U se r M a n U a Enter new Group of Systems Name MS Great Adventure MS Great Adventure System MS Great Adventure System 1 MS Great Adventure System 2 Figure 46 Create a Group for a ship and add the Systems on the ship Hydrographic Data Protection Suite Page 44 Hydrographic Data Protection Suite U se r M a n u a 2 System Groups last creation time 21 03 2014 17 09 19 last modification time 21 03 2014 17 09 19 Group list NN Na
15. are listed in the list on the left The filter field above the list can be used to find the desired cells The right list contains the cells currently part of the Exchange Set CD Definition In this example all cells are marked by pressing Ctrl A and the arrow button adds the selection to the list of assigned cells Pressing Ok confirms the selection and closes the Cell Selector Form The new Exchange Set CD Definition can now be saved Figure 21 Note For your production Exchange Set CDs ensure that the README TXT content is always informative and up to date F Exchange Set CD Detail Enter new Exchange Set CD Definition Name Hawaii Complete USZHAD3M USZHADEM USZHADEM USZHADFM USZHAOBM USIHADAM US 3HA OM US IHAZOM USIHAGOM USIHA FEM US Celle 4HA14M US4HAZ3M US4HA30OM US4HA51M US4HAGIM USSHAZOM USSHA72M US4HA73M US5SHA06M US5SHAIZM US5H di A13M US5HA15MUS5HA16MUS5HA17M US5HA18M US5HA27MUS5HA22M US55HA23M U55HA24M US5HA30M US5HA52 M US5HA53M US5HA54M US5HA55M US5HA56M US5HA62M US5HAG3M LUSSHATEM Readme Ted Please edit the Readme bd information for this exchange set Note Data Servers currently use the README TXT to encode important information that relates to their services This information can include the following 1 General Service information provided by the Data Server 2 Specific information provided by REN Cs and individual ENC producers conceming their ENC data 3 Any cautionary information about specific ENC data
16. customer This chapter explains the process of granting access to data in a step by step manner An example Lease is fully implemented and finally Cell Permit Files are created for two example systems The agreement to be mapped in the Hydrographic Data Protection Suite is summarized in two sentences e Burgham Chart Service grants access to high resolution charts for five Hawaiian harbors Nawiliwili Honolulu Kahului Kona and Hilo to the whole fleet of Caribbean Dream Cruises Inc e The contract is not time limited and can be terminated by both sides with a notice period of 3 months 4 3 1 Cell Packages Setting up the Product Portfolio A Cell Package is a named set of cells Cells can be grouped into Cell Packages by geographic regions or according to any other criteria like for instance detail level purpose or origin Cell Packages can be thought of as sales articles For the Hydrographic Data Protection Suite Cell Packages are the smallest units of data to which access can be granted If access shall be granted to a single cell a Cell Package must be created containing only this one cell The data being provided to Caribbean Dream Cruises in the example scenario currently consists of five cells one for each harbor Nawiliwili Honolulu Kahului Kona and Hilo To create the Cell Package for this data the Grant Access button on the main window is pressed to open the Manage Systems Groups and Leases form Pressing the Add
17. wizard page is shown in Figure 4 It reports the creation of a new private and public key pair and a self signed public key and provides additional information on the Unauthorized Data Server Mode and the procedure of requesting the Data Server status at the International Hydrographic Bureau IHB A link allows opening the directory in which the new Data Server Credential files were created in windows file explorer conveniently Figure 5 shows a listing of the new files Organize 2 ffnen Share with Burn New folder ie Favorites Name Date modified HE Desktop 25 BCS pub 12 03 2014 16 46 Microsoft Office Downloads BCSPrivateKey pqgx 12 03 2014 16 46 PQGX File Recent Places BCSSelfSignedPublicKey txt 12 03 2014 16 46 Text Document data_server_into txt 12 03 2014 16 46 Text Document Libraries Documents Figure 5 New Data Server key files The Data Server Credential files are named lt Short Name gt pub public key lt Short Name gt SelfSignedPublicKey txt self signed public key lt Short Name gt PrivateKey pqgx private key where lt Short Name gt is substituted with the acronym or short name that was entered in Step 1 Figure 2 Note Please make backup of these files by copying them to a secure location After creating backup copies the private key should be deleted from the Data Server Credentials directory The Hydrographic Data Protection Suite is now operating in Unau
18. 20 28 11 03 2014 20 28 Figure 63 The Cell Keys overview 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 ly Create CNI Keys K Close The table contains one entry for each cell and shows the creation time for the current Cell Key Cell Key 1 and the last Cell Key Cell Key 2 Cells can be selected and Hydrographic Data Protection Suite Page 57 Hydrographic X Data Protection Suite User Man ual deselected all at once using the buttons above the table or individually using the checkboxes in the leftmost column The Cell Key Creation for the selected cells is started by pressing the Create Cell Keys button on the Cell Keys tab page The Cell Key Generation Log is displayed to the user In the case shown in Figure 64 the Minimum number of days for cell key renewal setting was set to 7 F Cell Key Generation Cell Key Generation Log Message Last cell key for cell US2HAQ3M created 5 days ago Skipped G Last cell key for cell US2HA05M created 5 days ago Skipped G Last cell key for cell US2HAO6M created 5 days ago Skipped Last cell key for cell US2HAO7M
19. 36 Lease Ena DATO norris i 38 A e e o SC A 15 16 License ROQUES serie Em 13 Manacor e RE DIR 53 o ads sir EE testeutnceeagaaeu dE E DD AEE Sei os das 12 PWS NON contamination cod Ein UE nte Om 11 o o ERROR EE DRDS DR 11 REQUIRE Mec rada 7 A o o e il Co EEE E EE Eo ECO E 59 UPDATE aCe g ye Te SEEC D idilio pos 29 Hydrographic Data Protection Suite Page 68
20. Data Server Certificate When the Data Server Certificate is received from the IHB it must be imported into the Hydrographic Data Protection Suite to change the operation mode from Unauthorized Data Server Mode to the normal operation for an IHO accredited Data Server Selecting Administrative Tasks gt Import Data Server Certificate form the Tools menu on the main window opens the Import Data Server Certificate form Figure 56 0 CDs in service Import Manufacturer Keys Exchange Sets Reassign CD Numbers Protect Data No exchange set was built yet Grant Access O Systems O leases and 0 packages in database Figure 56 Import Data Server Certificate Pressing the Open button starts a file selection dialog for the Data Server Certificate file certificate The public key file pubk must reside in the same directory and will be automatically imported Note The software assumes that the IHO certificate file is named certificate and the public key file is stored in the same directory and is named pubk as shown in Figure 57 If your certificate and pub public key files are named differently you must rename them first Hydrographic Data Protection Suite Page 51 Hydrographic Data Protection Suite User Man ual Organize v Open Burn New folder E 0 A Music Name Date modified Type Pictures a Videos certificate 11 12 2013 12 52 File metadata 11 12 2013 12 52 File pubk 11
21. Dream Cruises Harbour Charts Notice period 3 months See L20140301 001 for details Lease end gl Cell Permit r oe Fixed dates 30 Jun 31 Dec Packages Hawaii High Resolution Harbour Charts Member groups Caribbean Dream Cruise Ships Figure 40 The Lease can be created now The The Lease itself needs no editing anymore and can now be saved by pressing Ok new Lease is now displayed in the Leases overview as shown in Figure 41 Hydrographic Data Protection Suite Page 40 Hydrographic Data Protection Suite U se r M a n u a 1 Lease creation time 21 03 2014 17 05 44 last modification time 21 03 2014 17 05 44 gt x x Dx Figure 41 The new Lease in the overview table 4 3 4 Add Customer Systems Burgham Chart Service has received a list of systems aboard all cruise ships in the Caribbean Dreams Cruises Inc fleet This section demonstrates as an example how systems for one ship the MS Great Adventure are added to the Hydrographic Data Protection Suite Pressing the Add button on the Customer Systems tab page Figure 42 opens the Customer System Detail form for entering new Systems The forms for two example Customer Systems are shown in Figure 43 and Figure 44 Hydrographic Data Protection Suite Page 41 Hydrographic Data Protection Suite U se r M a n U a Figure 42 The empty Customer Systems overview table Name MS Great Adventure
22. Hydrographic Data Protection Suite User Manual March 2014 Qcomans gt Hydrographic X Data Protection Suite User Man ual Table of Contents TABLE OF CONTENTS urinarias JI E INTRODUC TION eo EE EE intimida il 4 PE E E E E E E E E A 4 2 C Onen O iee o buat pin neoon brote 4 E Bo E A EE AE RN RE EAA P A ER DN eden 4 Ze OVERVOEREN OO G 5 24 Tbe SD Data Server ROE rrondo aeeai eaea oiei 5 22 Data Protection suite ONES Winston EE 5 221 Protec Dat leiste 5 2 2 2 Granting Access to the Encrypted Data o oooooooonococncnnnnnnnnnnnnnnnnnnnnnnononnnnnnnnnnnnnnononononnnnnonnnnnnnnnnnnnnnos 5 2 3 Integration with Other Systems sisiasintaa alta iia iia 6 de TIDSPLAN ntsc pto piratas 7 3L General Considerado sicario caca eA cities 7 A A ana ES ccs ae sashes Sd neues ed 7 o A o AS E E E a 7 3 4 Initial Configuration W1Zard ccccccccccccccccccecceccaaueesssseseseeeecceeeeeeeeeeeaaaaasassssseseeeeeeeeeeeeeeeaaaaas 8 34 1 Step 1 Entet a Data Server Name cascada iio ii 9 342 Sicp2 Data Server Credentials ssscccsesasievicecehccastaciondes ce an a REEE EE e E Ea 9 SA dlcp o Load Data Server Private KOy cunas 12 3 4 4 Step 4 Enter License Request Information ccccccececcceecccccceeeaeseseeseseccceeeeeeeeeeaaaaasssseeeeeeeees 13 3 4 5 Step 5 Send License Request File to Geomaris ccccccccccccccccceeseseeesseeeecceceeceeeesaaaeasesseseeeeeeeess 14 3 4 6 Step 6 Importing Data P
23. Hydrographic Data Protection Suite User Man ual Date Settings D Administrative Tasks gt Import Data Server Certificate 3 CDs in service Import Manufact Keys Reassign CD Numbers Exchange Sets Protect Data The last exchange set was built 5 days ago on 12 03 2014 17 06 Cell Permits Grant Access 2 Systems 1 lease and 1 package in database Figure 59 Import Manufacturer Keys Hydrographic Data Protection Suite Page 54 Hydrographic Data Protection Suite U se r M a n u a Please open the Manufacturer Key File in CSV Format Manufacturer Keys in database IHO Key and 246 OEM Keys Import date 17 02 2014 No file selected Note The file must have lines starting with the format Number M_ID M_KEY Status Date Organisation Supported seperator characters are and TAB Import Manufacturer Keys Number ID dal ai ui Organisation Figure 60 Import Manufacturer Keys Dialog 4 4 3 Reassign Exchange Set CD Numbers The CD numbering of the Exchange Set CD Definitions in the service should only be changed very rarely To change the CD number assignments select Administrative Tasks gt Reassign CD Numbers from the Tool menu of the main form as shown in Figure 61 The Exchange Set CDs can be moved up and down in the sequence using the up and down buttons Figure 62 After pressing Ok the CD numbers are changed For Exchange Set CD Definitions with new CD numbers ass
24. Mini ber of days fi Remark 1 Manufacturer a dad of days for mE Remark 2 Installation Default cell permit expiry date s Remark 3 Email j 180 days Remark 4 Contact Permit duration Groups remark label replacement Mini permit duration for Remarc 1 Email fixed date schedules in days Remark 2 Contact Leases remark label replacement Remark 1 Lease ID Remark 2 Customer ID Packages remark label replacement Remark 1 Remark 2 Figure 65 Label replacements Figure 66 Miscellaneous settings 4 5 1 Remark Label Replacement The labels for text fields and column headers on the forms for Customer Systems Groups Leases and Cell Packages can be customized in the Label Replacement tab of the settings dialog Figure 65 and Figure 67 The replacements are then used throughout the Hydrographic Data Protection Suite s Graphical User Interface and provide a means to define custom data fields for the user Figure 67 shows an example where the default labels Remark 1 and Remark 2 have been replaced with Manufacturer and Installation for Customer Systems The custom labels are used for the filter input fields and the column headers on the Customer Systems tab page and for the text boxes on the Customer System Detail form Hydrographic Data Protection Suite Page 59 Hydrographic Data Protection Suite User Man ual 2 Customer Systems last creation time 13 03 2014 13 39 02 last modification t
25. age Cells and Exchange Set CDs window provides the user interface for managing and building Exchange Set CDs The Exchange Set CD Definitions tab page Figure 18 consists of two parts Exchange Set CD Definition Table The table displays some information on the Exchange Set CDs like the cells being shipped with the Exchange Set CD and the time the last BASE or UPDATE Exchange Set CD was built A status column indicates if the referenced cell data in the Cell Pool is set up correctly Action Panel The Action Panel provides an Add Edit and Remove buttons and a link to conveniently open the Exchange Set CD build output directory e Clicking the Add button adds a new Exchange Set CD Definition Hydrographic Data Protection Suite Page 22 Hydrographic Data Protection Suite U se r M a n u a e Double clicking a row in the table or pressing the Edit button opens the selected entry for edit e Pressing the Remove Definition button removes the selected Exchange Set CD 0 Exchange Set CD Definitions O records with issues Output Directory C Users Public Documents Data Protection SuitelEx Set Build O FE Figure 18 Add a New Exchange Set CD Definition In this section the Exchange Set CD Definition Hawaii Complete is created containing all available cells from the Cell Pool Pressing the Add button on the Action Panel of the Exchange Set CD Definitions tab Figure 18 page opens the Exchange Set CD Det
26. ail form Figure 19 Hydrographic Data Protection Suite Page 23 Hydrographic X Data Protection Suite U se r M a n u a PS Exchange Set CD Detail Enter new Exchange Set CD Definition Name Cells Click edit to select gt Please edit the Readme bd information for this exchange set Note Data Servers currently use the README TXT to encode important information that relates to their services This information can include the following 1 General Service information provided by the Data Server 2 Specific information provided by RENCs and individual ENC producers conceming their ENC data 3 Any cautionary information about specific ENC data such as overlapping ENC coverage or known issues with specific cells Figure 19 Enter new Exchange Set CD Definition An Exchange Set CD Definition name must be entered and cells must be assigned The Edit button on the right side of the Cells field opens the cell selection form shown in Figure 20 PS Select cells for Hawaii Complete Cells in Hawaii Complete All availible cells USZHADIM USZHADEM USZHADEM US2HA0O7M USZHADEM LIS3HAD4M LIS3HA10M LIS3HA20M LISQHAENM Hydrographic Data Protection Suite Page 24 Hydrographic Data Protection Suite U se r M a n u al Figure 20 Cell Selector Form Add all cells to Exchange Set CD Definition The cells available in the Cell Pool and not yet assigned to the Exchange Set CD Definition
27. been copied yet The files will be added later in this section to demonstrate building UPDATE Exchange Set CDs Local Disk C Users Public Documents Data Protection Suite Cell Pool gt v gt Search Cell Pool p aja e Organize Include in library Share with Burn New folder x Favorites ME Desktop J Downloads a Recent Places Libraries _ Documents a Music Pictures a Videos Mk Computer A US2HA03M US2HA07M US3HA10M US3HA76M US4HA30M US4HA70M US5HA06M J US5HA15M US5HA18M US5HA23M US5HA52M J US5HA55M US2HA05M US2HA08M US3HA20M US4HA14M US4HA51M US4HA72M US5HA12M USSHA16M USSHAZIM USSHA24M US5HA53M USSHA56M US2HA06M US3HA04M US3HA60M US4HA23M US4HA61M US4HA73M USSHAI3M USSHA17M US5HA22M USSHA30M USSHA54M USSHA62M amp Local Disk C Local Disk D SYSTEM RESERVEL A 39 items State BR Shared Figure 16 Hawaii Cell Directories in the Cell Pool Directory USSHA63M USSHA72M _HowToPopulateTheCellPool txt After arranging the cell data in the Cell Pool Directory the Refresh button on the Action Panel is pressed to update the Cell Poo table Figure 17 Hydrographic Data Protection Suite Page 21 Hydrographic Data Protection Suite User Man ual xchange Set CD Definitions Cel Pool Cal Keys
28. button on the Cell Packages tab page opens the Cell Package Detail form Figure 30 Hydrographic Data Protection Suite Page 32 Hydrographic Data Protection Suite User Manual FEZ Cell Package Detail Enter new Cell Package esolution Harbour Charts Click edit to select gt Figure 30 Cell Package Detail form The Edit button opens the Select Cells form where the five harbor cells are selected as shown in Figure 31 After pressing Ok on the Cell Package Detail form detail the Cell Package can then be saved Figure 32 E Select Cells l Cells in Hawaii High Resolution Harb Filter Name x Al available cells Selected cells US1HAGIM US2HA403M US2HADSM US2HADGM US2HAQ7M US2HADSM US3HADAM US3HATOM 15H 4200 MEAT US5HA17M USSHAZ2M USSHA55M USSHAG3M Figure 31 Select Cells for Cell Package Figure 33 shows the Cell Packages tab page with the new Cell Package Hydrographic Data Protection Suite Page 33 Hydrographic Data Protection Suite U se r M a n U a Enter new Cell Package Hawaii High Resolution Harbour Charts US5HA12M US5HA17M US5SHA22M USSHASSM USSHAG3M Dao Figure 32 Save new Cell Package 1 Cell last creation time 13 03 2014 13 03 23 last modification time 13 03 2014 13 03 23 Figure 33 Cell Packages overview Hydrographic Data Protection Suite Page 34 Hydrographic X Data Protection Suite U s
29. containing US1HA01M and US2HA05M 004 29 Figure 27 New ltems Available for Exchange Set CD re 30 Figure 28 Choose to build BASE or UPDATE CD erre 30 Figure 29 Build summary of the Update Exchange Set CD build 31 Figure 30 Cell Package Detail form erre rerere serena neeanao 33 Figure 31 Select Cells for Cell Package cooccccocccccoccnocccnccocnnonacncnnnnnonncncnnnnononcnnnos 33 Figure 32 Save new Cell Package erre eeere re rera aerea renado 34 Hydrographic Data Protection Suite Page 66 Hydrographic Data Protection Suite User Manual Figure 33 Cell Packages OVervieW ccoocccccocncccocnccncnoconnnonnnononnnnnnncnonnnnnonnnnnnnnnnnonnnnnos 34 PIG Ure 34 Group Detalla eeaicasansins ooo toria 35 Figure 35 Group Of Systems OVeIVIOW occcooccccoccnccncncconnnonnnoncnnnnonnrnnnnnnnnnnnncnnnninenennnos 36 Figure 36 LEASES OVeIVIS W ocooococococonoconoconocononononononononononnonanonanonanonanenanenanenanenanenanes 37 Figure 37 Lease Detail ForM ocococccococonoconoconoconoconocononononononononononononanonanonanenanenanes 38 Figure 38 Select Cell Permit Expiry Date ScheMe oooocccccoccccccnonccoccnnnncnncnnnnccncnnnaninnnns 39 Rs ae o o AMM Pen 39 Figure 40 The Lease can be created NOW cccccccsecccssecceeeceueecseceueeseueesseessueenaees 40 Figure 41 The new Lease in the overview tlable
30. ctendudeatandeinwtteleinedandeientcadsinctandeientueds 50 Figure 56 Import Data Server Certificate cocooocccconcncocnncconnnonacnnnnnnnonacnnnnnnononcnnnns 51 Figure 57 The Certificate and Public Key file ready for import cccocccoccccocnccncncnos 52 Figure 58 The Import Data Server Certificate dialog after successful validation 52 Figure 59 Import Manufacturer Keys occooccocccoccccncononocononanonanonanonanonanonanonanonanenanenanos 54 Figure 60 Import Manufacturer Keys Dialog erraram 55 Figure 61 Start CD Number Reassignment cccocccccccncccccnccncnncncnnnnncncnnnnnnnncncnnnnnnnncnnnos 56 Figure 62 CD Number Reassignment FOrm ccccccccssecseeeceeeeceeeeaeeeeeeeeaeeesaeeesaees 56 Figure 63 The Cell Keys overview occoocccccocccocccnccncnnconononnnnnnnnnnonnrnonnnnnonnnnonnnnnnnncnnnos 57 Figure 64 Cell Key Generation LoOOJ cccoccccoccnccoccnococcnococononnnnnnncnononononannnonanenoncnonos 58 Figure 65 Label replacements ccccseccceeccsececeeeccucecueeceeeceueesueseueeseueeneeeseueenaess 59 Figure 66 Miscellaneous settings oococonoconoconoconocononononononononanonanonanonanonanenanenanes 59 Figure 67 Custom labels replace the default remark labels for Systems 60 Figure 69 Fred ume A RR 61 Figure 69 Fixed lateS occcoccccoccccccncoocccncnconcnnnnnnoncnonnnnnnnnonnrnnnnnnnnrnnnnnnnnnnnnnrnnnnnnnnenonass 61 Figure 70
31. ction Suite would only be used to execute the Cell Permit File creation process The Hydrographic Data Protection Suite supports adding custom fields to Systems Groups and Leases This information can be used by an external Cell Permit File distribution system Hydrographic Data Protection Suite Page 6 Hydrographic X Data Protection Suite User Man u al 3 2 3 3 Installation General Considerations The Hydrographic Data Protection Suite is a desktop application for single user operation All data is stored in local files and no network connectivity is required The application must be closed to make backup copies of the Data Directory Copying the full Data Directory represents a full backup including input cell data and Exchange Set CD build output The Config directory in the Data Directory contains the text files storing the Customer Systems Groups of Systems Leases Cell Packages and Exchange Set CD Definitions Requirements In order to install the Hydrographic Data Protection Suite on a client PC the following requirements must be met Memory NG p HDD free sm Operating System Windows 7 Windows Server 2008 or higher NET Framework NET Framework 4 5 or higher Security Must be a user domain with administrative rights on the client machine Connectivity No network connectivity required Table 1 Installation requirements Installation To install Hydrographic Data Protection Suite on a cl
32. e Lease end date will be set when a party terminates the agreement 4 3 3 2 Cell Permit Expiry Scheme The concept of Cell Permit Expiry Schemes is explained in detail in CELL PERMIT EXPIRY SCHEMES Pressing the Edit button on the right side of the Cell Permit Expiry Scheme row of the Lease Detail form Figure 37 opens the dialog shown in Figure 38 Hydrographic Data Protection Suite Page 38 Hydrographic X Data Protection Suite U se r M a Nn U a l A Fixed Dates Cell Permit expiry scheme is selected Cell Permits expire at the end of June or at the end of December dependent on the time of Cell Permit creation Figure 38 Select Cell Permit Expiry Date Scheme 4 3 3 3 Select Data _ Pressing the Edit form opens the Select Cell Packages form Figure 39 and the Cell Package containing the harbor charts is selected Figure 39 Select Cell Package Hydrographic Data Protection Suite Page 39 Hydrographic X Data Protection Suite U se r M a n U a 4 3 3 4 Save the New Lease The Lease Detail form shown in Figure 40 now shows the settings we have made The empty list control labelled All selected systems shows that at the Lease does not cover any Customer System for which Cell Permits will be created After adding Customer Systems to the Group Caribbean Dream Cruise Ships the Lease Detail form will show these systems in the All selected systems list Enter new Lease Caribbean
33. e r M a n u a 4 3 2 Create a Group of Systems for the Lease Using a top down approach an empty Group of Systems is created representing all systems covered by the Lease Then the Lease is created and finally the Group of Systems is populated with the Customer Systems for which Cell Permits shall be created Add button on the Groups of Systems tab page opens the Group Detail dialog Figure 34 The form provides fields for the group name a description and two remarks and lists containing the System Groups and Customer Systems which are members of the group buttons below the member groups and member systems lists are inactive in because neither a Group of Systems nor a Customer System is defined yet Adding and removing member groups and systems to a group is explained in section ADD CUSTOMER SYSTEMS Enter new Group of Systems Name Caribbean Dream Cruise Ships Description All ships of Caribbean Dream Cruises Remark 1 Customer ID 123456789 Remark 2 Member groups Group name After pressing Ok Figure 35 Hydrographic Data Protection Suite Page 35 Hydrographic Data Protection Suite U se r M a Nn u a Figure 35 Group of Systems overview 4 3 3 Create a Lease Now that a Cell Package exists containing the harbor cells and a System Group exists representing the Customer Systems for which Cell Permits shall be created the Lease can be created Pressing the Add button on
34. e trial license store the license file to a directory of your choice If not already running start the Hydrographic Data Protection Suite The Import Data Protection Suite wizard page is displayed Figure 11 4 Initial Configuration Wizard geomaris Step 6 Import License Ifyou have received a license for the Hydrographic Data Protection Suite as email attachment save the license file to a directory of your choice and click Import License to import the license file into the application E Import License Figure 11 Import the license file Press Import License and select the license file license lic in the file selection dialog After successful import you see the page shown in Figure 12 The Done button closes the Initial Configuration Wizard and the main window of the Hydrographic Data Protection Suite is shown Figure 13 The application is now ready to use Hydrographic Data Protection Suite Page 16 Hydrographic Data Protection Suite U se r M a n u a Qcomoaris Configuration finished ee You can now start using the Hydrographic Data Protection Suite Figure 12 Wizard configuration finished Hydrographic Data Protection Suite Page 17 Hydrographic Data Protection Suite User Man ual 4 Using the Application 4 1 The Main Window The Hydrographic Data Protection Suite main window Figure 13 provides two buttons one for each fundamental group of tasks of a Data Servers service
35. ease A Lease grants access to certain data specified by Cell Packages to a set of systems specified by Customer Systems and Groups of Systems Manufacturer A five digit number assigned to manufacturers by the IHO The Manufacturer Key must Key be known to create valid Cell Permits for the manufacturer s systems Manufacturer A list of IHO accredited equipment manufacturers with their Manufacturer IDs and Key List Manufacturer Keys These keys are required to create Cell Permits for systems built by the manufacturers An updated list is distributed by IHO whenever new OEMs are registered The National Oceanic and Atmospheric Administration NOAA is a US federal agency focused on the condition of the oceans and the atmosphere Original Equipment Manufacturer In the context of S 63 an IHO accredited manufacturer of S 63 compliant client software S 57 Transfer standard for ENC defined by IHO S 63 IHO Data The publication S 63 IHO Data Protection Scheme describes the recommended Protection standard for the protection of ENC information It defines security constructs and Scheme operating procedures that must be followed to ensure that the data protection scheme is operated correctly and to provide specifications that allow participants to build compliant systems Hydrographic Data Protection Suite Page 65 Hydrographic Data Protection Suite User Man ual Unauthorized The Hydrographic Data Protection Suite op
36. eate Cell Permits RE Figure 51 Create Cell Permits tab page FE Confirm Cell Permit Creation Create Cell Permits Create cell permits for all systems E Delete all old pennit files ay eee Figure 52 Confirm Cell Permit creation After all Cell Permit Files have been written the Cell Permit Creation Summary form is displayed as shown in Figure 53 The summary form provides a link to the Cell Permit File output directory and a list of log messages one for each Customer System Hydrographic Data Protection Suite Page 48 Hydrographic X Data Protection Suite User Manual Note The warnings in the summary in Figure 53 indicate that the Cell Permit duration is shorter than defined in the Lease due to the trial license The latest possible Cell Permit expiry date during the trial period is one week after the trial license expires Permit Files for 2 Systems Created CilsersiPubliciDocumentsiData Protection Surte Generated Cell Permit Files Click to open Permit Creation Log DM eee d MS Great Adventure System 1 The expiry date of some of the 5 permits was set to 08 04 2014 one week after the ti EN NE Gerd Ande ae Te eiii of se nie ee sido DE DA SOMA pre eek nei Figure 53 Cell Permit Creation Summary pe Se e e bh Data Protecti Generated Cell Permit Files P Search Genera pl Organize Open Include in library Share with
37. end Cell Permit Emir Sd E Fixed dates 1 Jan 1 Jul Packages Hawaii High Resolution Harbour Charts Member groups Group name Cambean Dream Cruise Ships MS Great Adventure System 1 MS Great Adventure System 2 Figure 70 Open the Enter Expiry Date s dialog Hydrographic Data Protection Suite Page 62 Hydrographic Data Protection Suite U se r M a n u a E Enter Expiry Date s a Fixed Time Interval con io Fixed Dates Figure 71 Editing the Cell Expiry Date Scheme Hydrographic Data Protection Suite Page 63 Hydrographic Data Protection Suite User Man ual 5 Annex 5 1 References IHO S 63 IHO Data Protection Scheme Edition 1 1 March 2008 S 63 Data Server Agreement Version 1 1 1 S 63 Data Server Request Form Edition 1 2003 5 2 Glossary BASE Exchange An Exchange Set CD containing the complete data base cell files update cell files and Set CD supplemental TXT and TIF files for all cells being assigned to the Exchange Set CD Definition Cell Key A key used to encrypt and decrypt ENCs in compliance with S 63 Cell Package A named set of cells A cell package corresponds to a sales article for the Hydrographic Data Protection Suite Cell packages are the unit of data to which access can be granted Cell Permit A string token providing access to one cell for particular system for a certain time period Contains the Cell Key in an encrypted form Cell P
38. epad Pictures Share with E Videos E Mit Bitdefender scannen Restore previous versions k Computer amp Local Disk C Local Disk D Copy 5 Documents SYSTEM RESERVED F E aan amp Fax recipient w Acer G Delete 3 Mail recipient gt DATA H ARIS 9 DVD RW Drive E BCSLicenseRequest Irq State BB Shared Properties eel A yoda 53 l LRQ File Date modified 11 03 2014 Liss ware treateorrruszurr x Disconnected Network Drive T Send to 1 Compressed zipped folder Cut ME Desktop create shortcut Figure 10 Send the license request to register geomaris com If you right click in the windows explorer on the license request file you can use the Send to Mail Recipient functionality if available on your system Figure 10 The reply with a trial license file attached is usually sent within a few minutes to the email address given in Step 4 Note If you don t receive a reply within an hour check that your email address is correct and check your spam folder Pressing Next will proceed to the Import Data Protection Suite License page Figure 9 lf you cancel the wizard and start the Data Protect Suite again later the configuration procedure will continue from this point Hydrographic Data Protection Suite Page 15 Hydrographic X Data Protection Suite User Man ual 3 4 6 Step 6 Importing Data Protection Suite License When you receive th
39. eration mode if no Data Server Certificate Data Server was imported The Data Server s self signed public key is used instead of the official Mode Data Server Certificate This mode corresponds to an S 63 Data Protection Scheme with the Data Server itself acting as the Scheme Administrator See S 63 Data Protection Scheme document for details UPDATE An Exchange Set CD containing only the new base cell files update cell files and Exchange Set supplemental files not yet delivered with the last BASE Exchange Set CD CD Tabl e 2 Glossary 5 3 List of Tables Table 1 Installation requirements oocooccccnncccncconoconocononononononanonononononanonanonaninanenanenanes 7 Fable GOSS eed cari esen ceed eae spas Icasa digo sia d pad Sica ads teat ena Sina d aros ira dead ira d sds E cines 66 5 4 List of Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Figure 14 Figure 15 Figure 16 Figure 17 Figure 18 Figure 19 Figure 20 Figure 21 Initial Configuration Wizard Start Page eres 8 Enter a Data Server name errar errea renan rre narra anna 9 Import or create Data Server credentials eres 10 New Data Server credentials created eres 10 New Data Server key files errar rre arena anne 11 Load the private key file secos tica 12 Successfully loading the private key
40. ermit A rule to determine the expiry date for Cell Permits at the time of Cell Permit creation Expiry Scheme Cell Permit File A file containing a number of Cell Permits for one system The file name must be PERMIT TXT for import into the system Cell Pool The complete cell data from which the Exchange Set CDs are built Cell Pool The directory containing the Cell Pool data Directory Customer An S 63 compliant software system identified by an ENC User Permit System Data Directory The directory in which the Hydrographic Data Protection Suite stores all data Typically C Users Public Documents Data Protection Suite if installed with the All Users option The Data Directory of an installation can be queried from the Help Menu on the main window Data Server An organization performing the role of creating S 63 Exchange Set CD and generating Cell Permits for authorized systems Data Server The Data Server s public key signed by the IHO Allows verifying that a file has been Certificate encrypted by an IHO accredited Data Server At the time of writing the certificate is delivered to the Data Server in a text file named certificate Data Server The set of keys required to perform the S 63 Data Server role The public and private Credentials DSA key pair a self signed public key and a Data Server Certificate Hydrographic Data Protection Suite Page 64 Hydrographic X Data Protection Suite User Man u al Term De
41. et US2HADS5M Files for dataset successfully added 5 57 update cell US H405M 000 successfully compressed and encrypted signature file created i 5 57 update cell US2HA05M 001 successfully compressed and encrypted signature file created 57 update cell US2HAD5M 002 successfully compressed and encrypted signature file created no i 5 57 update cell US2HA405M 003 successfully compressed and encrypted signature file created often Dama US2HADGM Fles or dama acc aded O Figure 24 Exchange Set CD Build Summary form Hydrographic Data Protection Suite Page 27 Hydrographic X Data Protection Suite User Man ual The content of the output directory is shown in Figure 25 The content of these two folders and the SERIAL ENC file constitute the S 63 Exchange Set CD to be delivered to client systems z ex i lt gt l rr E a e i Sal A h 1Ha C v Search CD 1 Y Oo S 3 DL SE Organize x Include in library Favorites Name EE Desktop b ENC ROOT l Downloads INFO lt Recent Places SERIAL ENC A Libraries Figure 25 The Exchange Set CD deliverables Hydrographic Data Protection Suite Page 28 Hydrographic Data Protection Suite User Man ual 4 2 4 Build UPDATE Exchange Set CDs An UPDATE Exchange Set CD can only be built if new cell data base cell or update have been added since the las
42. finition Data Server ID The two character alphanumeric Data Server Identifier assigned to accredited Data Server organizations by the IHO ECDIS Electronic Chart Display and Information System as defined by IMO A certified system for navigation with ENCs ECS Electronic Chart System A system for navigation with ENCs without the ECDIS certification Electronic Navigational Chart as defined by the ENC Product Specification ENC User Permit A 28 character hexadecimal string token identifying a system The ENC User Permit of a system must be known in order to generate Cell Permits for the system Exchange Set A set of encrypted ENC cells The smallest unit of S 63 data for data delivery An CD Exchange Set CD is identified by the CD number and a string encoding the week of creation e g WK12 14 Not necessarily delivered on a physical CD as exchange medium Exchange Set The definition of an Exchange Set CD consisting of a name and a set of cell names CD Definition Exchange Set CDs are instances of the Exchange Set CD definition containing the most up to date versions of the cells at the time they are built Used synonymous with Group of Systems Group of A group of systems containing subgroups and Customer Systems The Groups allow Systems organizing systems in a hierarchical structure reflecting the physical or organizational relations between systems International Hydrographic Bureau International Hydrographic Organization L
43. g representing the week of the release Therefore changes in the Exchange Set CD numbers can lead to ambiguities or name clashes resulting in UPDATE Exchange Set CD installation failures Hydrographic Data Protection Suite Page 26 Hydrographic X Data Protection Suite User Man ual 4 2 3 Build BASE Exchange Set CDs After pressing Build in the Exchange Set CD Definition table row the Confirm Exchange Set CD Build dialog is shown Figure 23 Pressing the Build Base CD button starts the build of the first BASE CD for the Exchange Set CD Definition Es contin change Se Bud ee Build Exchange Set CD 1 Hawaii Complete WK11 14 The input data in the cell pool and the README TAT content must be up to date Figure 23 Confirm Exchange Set CD Build dialog Dependent on the number of cells and the system performance the build process can take some time After completion a build summary is shown providing a link to open the output directory in the file explorer Figure 24 E Exchange Set Build Summary Exchange Set CD CD 1 Hawaii Complete BASE WK11 14 successfully created EC iUsersiPubliciDocuments Data Protection SultelExcha Set Build Outputil Hawai CompletelD 1 Hawai Complete BASE WK 11 14 Click to open Build Log a d E Dataset US2HA03M Files for dataset successfully added S57 update cell US2HAD3M 000 successfully compressed and encrypted signature file created EE Added supplemental files Di Datas
44. ient PC follow the steps below Ensure you have the permissions to install software on your PC Start the installer on the target system Read and accept the End User License Agreement Accept or change the installation path on your computer Follow the instructions of the setup wizard and choose your desired installation options AE a a E Hydrographic Data Protection Suite Page 7 Hydrographic X Data Protection Suite User Man ual 3 4 Initial Configuration Wizard After installing the Hydrographic Data Protection Suite the Initial Configuration Wizard is launched when you first start the Application This wizard will guide you through the necessary steps to configure the Hydrographic Data Protection Suite to operate using the correct S 63 Data Server credentials Figure 1 4 Initial Configuration Wiza c E Qcomarsf Initial Configuration Wizard A Welcome to the Hydrographic Data Protection Suite Configuration Wizard This wizard will guide you through the necessary steps to setup an 5 63 Data Server and configure the Hydrographic Data Protection Suite to use your Data Server Credentials Figure 1 Initial Configuration Wizard Start Page Hydrographic Data Protection Suite Page 8 Hydrographic Data Protection Suite User Man ual 3 4 1 Step 1 Enter a Data Server Name In Step 1 enter the name of the Data Server and an acronym or short name Figure 2 4 Initial Configuration Wizar geomaris
45. igned the build history is cleared Hydrographic Data Protection Suite Page 55 Hydrographic X Data Protection Suite User Man ual Data Protection Suite Unofficial Data S Tools Data Settings D Administrative Tasks gt Import Data Server Certificate Import Manufacturer Keys Reassign CD Numbers N Protect Data The last exchange set was built 5 days ago on 12 03 2014 17 06 3 CDs in service Exchange Sets Cell Permits Grant Access 2 Systems 1 lease and 1 package in database Figure 61 Start CD Number Reassignment Reassign Exchange Set CD Numbers Exchange Set CD List Figure 62 CD Number Reassignment Form 4 4 4 Change Cell Keys 4 4 4 1 Cell Keys and Cell File Encryption The key used to encrypt a cell file as defined in the HO Data Protection Scheme S 63 is called the Cell Key lf the Cell Key is compromised the cell can be decrypted and used by anyone for an unlimited period without a Cell Permit Hydrographic Data Protection Suite Page 56 User Manual Hydrographic Data Protection Suite In order to prevent the unauthorized use of charts the Cell Keys should be changed from time to time 4 4 4 2 Cell Keys in Cell Permits A Cell Permit contains two Cell Keys in encrypted form the current Cell Key and the Cell Key used before By providing the last Cell Key in addition to the current one it is assured that Cell Permit Files created shortly after changing the Cell Key w
46. ime 26 03 2014 11 13 11 Filter Name Creation time select fy to select Ey Modification time select Installation Contact FZ Customer System Detail Edit Customer System MS Great Adventure System 1 Name MS Great Adventure System 1 Userpemit 3AD469828E40418967C512EE3231 Description Multi Function Console Figure 67 Custom labels replace the default remark labels for Systems 4 5 2 Miscellaneous Settings 4 5 2 1 Minimum number of days for cell keys renewal New cell keys should be generated from time to time as explained in section CHANGE CELL KEYS This option sets a minimum number of days before a new Cell Key can be generated The mechanism serves as a safety measure to avoid the situation that a customer cannot use Cell Permit Files with a fairly new Exchange Set CD 4 5 2 2 Default Cell Permit Expiry Date This field sets the default value for the Cell Permit Expiry Scheme The scheme will be used as a default for new Leases and can always be overwritten in the Lease Detail form Compare section CELL PERMIT EXPIRY SCHEMES 4 5 2 3 Cell Permit Duration The default Cell Permit duration for the fixed time interval expiry scheme Compare section CELL PERMIT EXPIRY SCHEMES Hydrographic Data Protection Suite Page 60 Hydrographic X Data Protection Suite User Man ual 4 6 Cell Permit Expiry Schemes The Cell Permit Expiry Scheme defines how the Hydrographic Data Pro
47. ion Suite Page 46 Hydrographic Data Protection Suite U se r M a n u a Edit pun Caribbean Deam ee pour Charts Name Caribbean Dream Cruises Harbour Charts Description Notice period 3 months See L201740301 001 for details Lease ID Customer ID Lease end E kar me Fixed dates 30 Jun 31 Dec Fackages Hawaii High Resolution Harbour Charts Member groups Grou name Caribbean Dream Cruise Ships M5 Great Adventure System 1 MS Great Adventure System 2 Figure 50 Lease detail with two systems 4 3 5 Create Cell Permits The Hydrographic Data Protection Suite creates all Cell Permits for all Leases at once and creates one Cell Permit File PERMIT TXT for each Customer System to which at least one Lease applies button on the Create Cell Permits tab page aie 51 starts the Cell Permit creation process The user is prompted to confirm the Cell Permit creation as shown in Figure 52 Depending on the number of Customer Systems the process of creating all Cell Permits can take some time Hydrographic Data Protection Suite Page 47 Hydrographic Data Protection Suite User Man ual Create Cell Permits Customer Systems Groups of Systems Leases Cell Packages Information 1 lease last edited 13 03 2014 13 30 2 systems last edited 13 03 2014 13 39 1 package last edited 13 03 2014 13 03 Create cell permits Create cell permits for all systems Cr
48. lsersiPubliciDocumentsiData Protection Suite ContigiDate Server Credentials Click to open as an email attachmentto register geomaris com You will receive an email within the next few minutes with a time limited trial license file from Geomaris After importing the license you can start using the Hydrographic Data Protection Suite Figure 9 License Request File Irq generated Hydrographic Data Protection Suite Page 14 Hydrographic Data Protection Suite User Man ual A license request file is generated and the next wizard page provides instructions on requesting a trial license from Geomaris and a link to conveniently open the directory see Figure 9 Click on the link to open the explorer window and email the license request file with file extension rg as an attachment to register geomaris com _ Alisa comaris Step 5 Send License Request To Geomaris Cc lt Users gt gt T gt Data Protecion Sue b Config b T Data Server Credentials Organize Open Share with Burn New folder Favorites Name Date modified EE Desktop BCS pub 11 12 2013 12 52 Microsoft Office P l Downloads BCSDataServerCertificate txt 11 12 2013 12 52 Text Document 3 Recent Places BCSEncryptedPrivateKey pqgx 11 03 2014 11 46 PQGX File BCSLicenseReauest ira 14 03 2014 11 53 LRQ File a Libraries A data sel Open 03 2014 11 38 Text Docur ment Documents f 7 Zip mais lu Edit with Not
49. me gt 16 5 r i ore Ce oo re O EE x Figure 47 Double click or the Edit button opens the group for editing Member groups in Caribbean Dream Cruise Ships Filter Name o K groups 5 Great Adventure Bo y Figure 48 Selecting Member Groups The Group Caribbean Dream Cruise Ships is opened for edit from the Groups of Systems overview Figure 47 and the new group is added as a member group Fehler Verweisquelle konnte nicht gefunden werden Figure 49 shows that the Group Caribbean Dream Cruise Ships now has the member group MS Great Adventure which contains the two Customer Systems on that ship Hydrographic Data Protection Suite Page 45 Hydrographic X Data Protection Suite User Manual The list labeled All selected systems confirms that the two member systems of the MS Great Adventure Group are correctly recognized as belonging to the Caribbean Dream Cruise Ships Group MS Great Adventure MS Great Adventure System 1 MS Great Adventure System 2 CIERTA Figure 49 Add group MS Great Adventure to Caribbean Dream Cruise Ships 4 3 4 1 Verify the Configuration Double clicking the table row or pressing the Edit button on the Leases tab page opens the Lease Detail form Figure 50 The All selected systems list now contains the two Customer Systems for which the Cell Permits can now be created Hydrographic Data Protect
50. ork correctly for data from Exchange Set CDs created both before and after changing the Cell Key If new Cell Keys are created twice in a short period this mechanism does not work As a safety measure the Hydrographic Data Protection Suite does not create a new Cell Key if the current one is younger than the minimum Cell Key age specified in the settings Compare section MINIMUM NUMBER OF DAYS FOR CELL KEYS RENEWAL 4443 Change Cell Keys in the Hydrographic Data Protection Suite The Manage Cells and Exchange Set CDs window is opened by pressing the Protect Data button on the main form Cell Key Creation is triggered from the Cell Keys tab shown in Figure 63 Exchange Set CD Definitions Cell Pool Cell Keys 38 Cell Keys The oldest cell key was created 8 days ago on 11 03 2014 20 28 13 Cell key list Select al Name Cell key 1 creation time Cell key 2 creation time US2HA03M US2HA05M US2HAO6M US2HA07M US2HA08M US3HAD4M US3HA10M US3HA20M US3HA60M US3HA76M US4HA14M US4HA23M US4HA30M US4HA51M US4HA61M US4HA70M US4HA72M US4HA73M US5HA06M US5HA12M 14 03 2014 18 31 14 03 2014 18 31 14 03 2014 18 31 14 03 2014 18 31 14 03 2014 18 31 14 03 2014 18 32 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014 20 28 11 03 2014
51. ost often in everyday language When the user chooses to build an Exchange Set CD the cell data from the Cell Pool Directory is encrypted and packaged Therefore the Cell Pool content must be carefully kept up to date and must contain only data ready for release Throughout this manual the usage of the Hydrographic Data Protection Suite is demonstrated by examples using NOOA cells from Hawaii 4 2 1 Populate the Cell FOOL When the user presses the Protect Data button on the main window the Manage Cells and Exchange Set CDs window opens lf the Cell Pool is empty the Cell Pool tab page is active Figure 14 Cell Pool Directory C Users Public Documents Data Protection Suite Cell Pool Figure 14 Empty cell pool table The Cell Pool tab page consists of three parts Hydrographic Data Protection Suite Page 19 Hydrographic X Data Protection Suite User Man ual Cell Table The Cell Table displays various details of the cell data in the Cell Pool A status column indicates if there are any issues with the cell data Examples for incorrect data are a missing base cell file a gap in the update sequence or incompatible edition numbers in an update cell file s DSID field The table can be sorted by a column by clicking the column header another click reverses the sorting order Filter The filter fields can be used to display only those entries matching the specified filter criteria If a fil
52. p manner 2 2 2 Granting Access to the Encrypted Data The Hydrographic Data Protection Suite allows efficient management of a large number of Customer Systems subscribed to the data service The systems can be organized into a hierarchical structure of Groups to model the real world physical and organizational structure in your system The agreements with your customers are entered into the system only once The objects representing such an agreement are called Leases Changes to the configuration must only be made when the composition of a Cell Package is changed or an aspect of an agreement changes All Cell Permits for all Customer Systems are created at the push of a button The expiry date for every single Cell Permit is automatically selected at the time of Cell Hydrographic Data Protection Suite Page 5 Hydrographic Data Protection Suite User Man ual Permit creation according to the rules specified in the Lease Section GRANT ACCESS describes the processes in a step by step manner The Cell Permit Files can then be distributed to the customers 2 3 Integration with Other Systems The configuration of Cell Packages Customer Systems Groups of Systems and Leases clearly defines which Cell Permits each Customer System gets As the components are stored in local files using simple text formats the configuration can be generated by another application providing the required data In this case the Hydrographic Data Prote
53. rotection Suite License ce cccccccccccccesessseeseeeeeeecceeeeeeeeeeaaaaaaaeseeeeeeeeees 16 a USING THE APELICA FLOWN rada 18 Mae Ma N OY ais 18 a ROU CU Do e e o siteaaans eadeseebeasgnaien 18 AnD Populi e Col OO sos A E 19 42 2 Manage Exchange Set CD Definitions ura 22 A Build BASE Exchange Set CDS iaa 2A 4 24 Build UPDATE Exchange Set EDS diia 29 do A E E SS sa gules ses A Seznssas et deeeesaeoeies 32 4 3 1 Cell Packages Setting up the Product Portfolio cccccccccccooooononnnnnncnnnnnnnnnnnnnnononnnnnannncnnnnnnnnnnnnnos 32 4 3 2 Create a Group of Systems for the Lea once icaboo 35 O E E T EE A EE AEE T T AE 36 doa A ai E E aE Ea 41 do Cree Cel POR A Pon e E e E O A 4 Ao Administrative Tasks sensies it obesos 51 4 4 1 Import Data Server Certificate oocccccccccccccnnoononnnonnnnnnnnnonnnnnnnnononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 51 4 4 2 Import Manufacturer Key LlSt cccccccnccccccocononononnnnnnnononnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnss 53 Hydrographic Data Protection Suite Page Ii Hydrographic X Data Protection Suite User Man u al 4 4 3 Reassign Exchange Set CD Numbers ccssssseeeeceecceeceeeaaaeeessesesececccceeeeeeeaaaaaasssseeeeeeeeeeseeeeeaaas 55 da Chance A den Cd 56 nn RD SRD RR RR o RR 59 AS Remark Label Replacement ci 59 4 5 2 Miscellaneous SCCM OS eric cue 60 do Cell Permit Expiry Schemes asesorias oir 61 A Gel
54. ssword protected Excel file from IHO Before importing the Manufacturer Keys into the Hydrographic Data Protection Suite it must be saved in CSV format The resulting CSV file can then be imported into the Hydrographic Data Protection Suite 4 4 2 1 Save Manufacturer List to CSV Comma Separated Values Export the manufacturer list worksheet to CSV format comma delimited or semicolon delimited as described in the documentation of the software e g Excel used for the conversion 4 4 2 2 Verify CSV Format Manufacturer Keys are imported from lines starting with the following format 123 10 45678 0K Name of OEM Organization Supported field separators are and the tab character t The field contents are Any number or an empty field The two character Manufacturer ID The five digit Manufacturer Key OK A date or an empty field The name of the organization or a se or a 4 4 2 3 Import CSV File From the Tools menu on the main window select Administrative Tasks gt Import Manufacturer Keys as shown in Figure 59 Pressing the Open button on the Import Manufacturer Keys dialog Figure 60 opens a file selection dialog for a csv file The selected file is parsed and manufacturer entries matching the previously described format are displayed in the preview table for verification Pressing the Import button then imports the new manufacturer list Hydrographic Data Protection Suite Page 53
55. such as overlapping ENC coverage or known issues with specific cells Figure 21 Enter an Exchange Set CD Definition After pressing Ok the new Exchange Set CD Definition is listed in the table on the Exchange Set CD Definitions tab page as shown in Figure 22 Hydrographic Data Protection Suite Page 25 Hydrographic Data Protection Suite U se r M a n u a Output Directory C Users Public Documents Date Protection Suite Ex Set Build O Figure 22 The new Exchange Set CD Definition was not built yet A light bulb symbol in the Has new items column indicates that there is cell data available for the Exchange Set CD that has not been part of past builds In this case the Exchange Set CD has never been built 4 2 2 1 Remove Exchange Set CD Definitions Exchange Set CD Definitions should be created and removed very rarely After the removal the CD number is blocked and not used for new Exchange Set CD Definitions CD number reassignment must be done explicitly as described in REASSIGN EXCHANGE SET CD NUMBERS Exchange Set CDs should be planned carefully and changes to the numbering should be made only very rarely for two reasons e A listing of the cells belonging to the CD number is shipped with every Exchange Set CD so customers can reasonably expect the same content to be associated with the CD number e S 63 Exchange Sets do not have names instead the identifier is built from the CD number and a strin
56. t BASE Exchange Set CD build After copying the NOAA cell data of US1HA0O1M to the Cell Pool Directory and adding the update file US2HA05M 004 to the cell directory US2HA05M the Refresh button on the Cell Pool tab page is pressed The Cell Poo table displays the new elements Figure 26 Exchange Set CD Definitions Cell Pool 39 Cells in Cell Pool The last cell data is from 23 01 2013 Filter Cell Name Product Spec Update Application Date select Ev to select Dr Issue Date Of Last Update select ry to select Intended Usage Cel list keue sus EEE AE ma qu Cell Update USIHADIM us 12012012 12012012 he Overview USIHADIA TXT us2Hao3m us 02102012 02 10 2012 USO02332 TXT us2Haosm lus 24082011 24082011 03012013 US002348 TXT uszHaoem us 16092011 16 09 2011 h US003555 TXT us2Haom us 04022011 04022011 US003616 TXT us2Haosm us 02022011 02022011 USOO3620 TXT ussHaoam us 03032011 03032011 13122011 US002216 TXT us 18 04 2012 18 04 2012 02 01 2013 1 US002347 TXT US 18 04 2012 18 04 2012 03 10 2012 US002358 TXT us 26042012 26042012 24 10 2012 US002435 TXT lus 20 10 2011 20 10 2011 US003635 TXT us 25092012 25092012 27122012 US002250 TXT us 17042012 17042012 21122012 6 h2 us002329 TXT
57. te and will be encrypted with a password The password must be entered at every application start Access to the private key file is required to change the password Figure 6 Note If you forget the password there is no way to retrieve the private key from the Hydrographic Data Protection Suite configuration files You must use your backup copy of the private key to reset the password Figure 7 shows the wizard after successfully loading the private key Hydrographic Data Protection Suite Page 12 Hydrographic Data Protection Suite U se r M a n u a geomaris Step 3 Load Data Server Private Key o Data Server Private Key loaded Figure 7 Successfully loading the private key 3 4 4 Step 4 Enter License Request Information To request a trial license enter your name company and email address as shown in Figure 8 and press Next Hydrographic Data Protection Suite Page 13 Hydrographic X Data Protection Suite U se r M a n u a geomaris Step 4 Request a Trial License e A Your First and Last Name John Smith Company Institution Burgham Chart Service GmbH Email your email address com Figure 8 Enter license request information 3 4 5 Step 5 Send License Request File to Geomaris geomaris Step 5 Send License Request To Geomaris a A license requestfile has been generated Please send the license requestfle BCSLicenseRequestirq from directory Ci
58. tection Suite selects the cell permit expiry date at the time a Cell Permit is generated A scheme best matching the cell permit delivery requirements is assigned to each Lease One of two schemes can be chosen 4 6 1 Fixed Time Interval current date expiry date y y y Figure 68 Fixed time interval The cell permit expiry date is calculated from the current permit creation date plus the given time interval in days 4 6 2 Fixed Dates current date expiry date fixed date T fixed date fixed date qp ecococooooooooooo gt Minimum permit duration Figure 69 Fixed dates The cell permit expiry date is the next available date from a list of dates specified by day and month If the time interval between the current date and the next date in the list is shorter than the Minimum Cell Permit Duration specified in the settings the date is skipped and the next date in the list will be used as the expiry date The Minimum Cell Permit Duration can be chosen in the Settings dialog as explained in Hydrographic Data Protection Suite Page 61 Hydrographic X Data Protection Suite U se r M a n U a MISCELLANEOUS SETTINGS The Cell Permit Expiry Date Scheme for a Lease can be selected as shown in Figure 70 and Figure 71 Edit Lease Carribean Dream Cruises Harbour Charts Name Caribean Dream Cruises Harbour Charts Description Notice period 3 months See L201402301 001 for details Remark 1 Remark 2 Lease
59. tered list of cell entries is displayed in the table the label under the table on the left side turns red and indicates that only a subset of the entries is shown Action Panel The Action Panel provides a link to conveniently open the Cell Pool Directory in the file explorer and the Refresh button Pressing the Refresh button updates the table to reflect the current state of the Cell Pool Directory For each cell a directory must be created in the Cell Pool Directory The directory name must correspond to the cell name The current versions of the base cell file update cell files and supplemental files TXT and TIF must be copied to this directory Figure 15 El o lt Data Protection Suite Cell Pool US2HA0SM z ra Organize Include in library Share with Burn New folder k Favorites z US2HA05M 000 US2HA05M 001 E Desktop US2HA05M 002 US2HA05M 003 i Downloads y US002346 TXT US002970 TXT Recent Places US00297L TXT US002972 TXT US002973 TXT USO0297 7 TXT Libraries Documents Figure 15 Cell Data Files for US2HA05M Pressing the link at the bottom of the Cell Pool tab page opens the Cell Pool Directory in the file explorer Figure 16 shows the Cell Pool Directory content after NOAA cells of Hawaii have been copied to it Hydrographic Data Protection Suite Page 20 Hydrographic Data Protection Suite User Manual The Hawaii cell US1HAO1M and the update cell file US2HA05M 004 have not
60. ternational Hydrographic Organization IHO uses the role name Data Server for organizations encrypting and signing ENC data and creating Cell Permits for authorized software systems At present the data server role is often associated with a small number of data servers like national hydrographic offices or RENCs Regional ENC Coordination Centers like IC ENC or PRIMAR providing ENC coverage of large areas for ocean going vessels S 57 based data Is increasingly used in numerous fields such as a wide range of port and offshore operations coastal and harbor surveillance environmental monitoring SAR or inland waterway transportation High resolution ENCs are produced to support operations in local waters or at offshore installations The Hydrographic Data Protection Suite enables companies and institutions to act as Data Servers in the S 63 Data Protection Scheme The customers can efficiently control access to their data and thus protect their economic basis 2 2 Data Protection Suite Overview 2 2 1 Protecting Data The Data Protection Suite provides functionality to create BASE and UPDATE Exchange Set CDs without worrying about any details The S 57 base cell files update cell files and supplemental text and picture files are copied to a Cell Pool Directory Then Exchange Set CDs are easily defined and can be built at the click of a button whenever new data is ready for release Section PROTECT DATA describes the process in a step by ste
61. the Leases tab page Figure 36 opens the Lease Detail form Figure 37 An optional description field and two additional fields for remarks allow attaching information to facilitate the management of a large number of Leases The other Lease properties are explained in the following paragraphs using the example Hydrographic Data Protection Suite Page 36 Hydrographic Data Protection Suite U se r M a n u a Figure 36 Leases overview Hydrographic Data Protection Suite Page 37 Hydrographic Data Protection Suite User Man ual E Lease Detail Enter new Lease Name Caribbean Dream Cruises Harbour Charts Description Notice period 3 months See L20140301 001 for details Lease ID Customer ID Lease end gr Cear Cell Permit Pony Te Fixed time interval 180 days Packages Click Edit to select packages Member groups All selected systems Group name System name Figure 37 Lease Detail Form 4 3 3 1 Lease End Date The Lease end date is the day the agreement ends No Cell Permit created on the basis of the Lease will be valid after this day The absence of an end date does not mean that Cell Permits for the Lease do not expire The next section deals with the rules the Hydrographic Data Protection Suite uses for determining Cell Permit expiry dates The Lease end date is not set in this example as the agreement stated in the introduction of GRANT ACCESS Is not time limited Th
62. thorized Data Server Mode This mode uses the auto generated self signed public key as the certificate ECS or ECDIS systems may reject Exchange Set CD content signed with this auto generated certificate as it is no official IHO Data Server Certificate Before you can operate as an IHO accredited Data Server you must send a Data Server Request to the IHB The two required documents are the Data Server Request Form and the Data Server Agreement Templates can be downloaded from the IHO website Hydrographic Data Protection Suite Page 11 Hydrographic X Data Protection Suite User Man ual The following items must be sent to the IHB e A Data Server Request Form e Two copies of the Data Server Agreement with all pages signed e The key files lt Short Name gt pub and lt Short Name gt SelfSignedPublicKey txt After receiving an official Data Server Certificate from IHB you must import this into the Hydrographic Data Protection Suite by following the instructions in IMPORT DATA SERVER CERTIFICATE 3 4 3 Step 3 Load Data Server Private Key 4 Initial Configuration Wizard geomaris Step 3 Load Data Server Private Key q Load the Data Server Private Key You will be prompted to select a password This password must be entered each time the Hydrographic Data Protection Suite starts Figure 6 Load the private key file After Step 2 the private key file must be loaded into the Hydrographic Data Protection Sui