User Manual - SIGLENT Technologies America

image

Contents

1. 10 20 30 40 0 BO mA LITO Meter Relative ALI Ort Auto m Trend Plot Figure 3 10 AC Current mA Measurement SHS1000 Series 49 SIGLENT A AE pp O 6 O ALTO 1 479A T T oO 4 2 3 4 5 DA Meter Felative AC Crt A Trend Plot Figure 3 11 AC Current A Measurement Operation steps 1 Press Meter to enter multimeter mode press F1 to choose DCI ACI measure 2 Insert the red probe to the V Q C banana jack input and the black probe to the COM Connect the other end of probes to the power or load to be measured 3 Turn on off the relative according to the real demand 4 Choose Manual or Auto according to the real demand 5 Read current value 50 SHS1000 Series SIGLENT Chapter 4 Using the Recorder Functions About this Chapter This chapter provides a step by step introduction to the recorder functions of SHS1000 series Handheld Digital Oscilloscope The introduction gives basic examples to show how to use the menus and perform basic operations The recorder mainly includes the following functions Trend Plot Trend plot is to save the measurements in the memory and then plot a graph of Scope or Meter measurements as a function of time Waveform Recorder Record real time waveform without gap or space That is to say every time the SHS1000 can save all captured waveform data and then replay them The maximal recording length of waveform recorder is 7M data points S
2. Figure 2 3 Channel Menu 2 Table 2 3 CH1 CH2 Function Menu 2 Option Setting Instruction Turn on off invert function Filter Enterthe FILTER menu TT To Zero Set waveform vertical position and trigger level to zero _ Fitter Type Jpp Limit a MOM Figure 2 4 Digital Filter Function Menu 8 SHS1000 Series SIGLENT Table 2 4 Digital Filter Function Menu Option Setting _ Introduction Diaital Filter Turn on the digital filter igital Fi j Turn off the digital filter H t Setup as LPF Low Pass Filter tct Setup as HPF High Pass Filter Type Lot Setup as BPF Band Pass Filter E St Setup as BRF Band Reject Filter I Use the up and down arrow keys to set Up_Limit ae Upp_ Limit Use the up and down arrow keys to set Low_Limit Return to the CH1 or CH2 menu Low_Limit Digital Filter Application Example Operation steps 1 Input a signal to CH1 and press AUTO Press CH1 to enter CH1 menu Press F5 to enter the second page of the CH1 menu Press F3 to enter the digital Filter function Press F2 to choose a filter type For example input a signal with BW 20M and choose Upp_Limit Use up and down arrow keys to set the filter range 7 Press F1 to turn on the filter oe N gt T T T T T L I alglent Trig d a eee E E TTTTTT rr TT T T T TT T T T T T T T l TT T T T T T to I EEEE
3. Category between two channelsreferences CAT I amp CAT 1000Vrms CAT lll 600Vrms Overvoltage Maximum Voltage Between Multimeter input Category reference and the ground CAT I amp CAT 600Vrms CAT III 300Vrms O It ane Maximum Voltage Category 1x CAT I amp CAT 300Vrms Max input Voltage for BNC 1x CAT III 150Vrms 10x CAT I amp CAT l 1000Vrms 10x CAT Ill 600Vrms Voltage port DC 1000V AC 750V Max input Voltage for Multimeter ae ee 9 me Current port mA AC 250V 10A input port Current port A AC 250V 600mA Ch C Mod AN aac dd gt 100 1 50MHz Rejection 66 SHS1000 Series SIGLENT Isolation Degree between gt 35dB Channels Acquisition System Sample l Real time Equivalent time Types Single Channel 32K double channels 16K l Common Deep Channel Mode Sampling Rat Storage Storage 40kpt Don t S support sa 500MSa 20kpt a s or Single Channel j 2Mpts below S Double 500MSa s or 20kpt P 1Mpts Channels below S Sample Peak Measure Average Sample Mode 4 16 32 64 128 256 Vertical System 5mV 200mV 1 6V Channel Voltage Offset Range 206mV 10V 40V 10 2V 100V 400V Vertical Resolution Channels Bandwidth 60 MHz 100 MHz Single shot Bandwidth 60 MHz SHS1062 100 MHz SHS1102 Lower Frequency Limit AC 3dB lt 10Hz BNC input DC Gain Accuracy 5mv div 100v div lt 3 DC Measurement Accuracy 3 X reading offset 1 of offset All Gain settings lt
4. O 200 2mV ld oo 100 2 300 400 SOs 600 ri MUAT _ gt UY N wieter Relatie DC Qn Manual W Trend Flot Figure 3 1 Multimeter User Interface the range of the multimeter staffs reading value input ports relative value the indicate of input connection test type operation type O S E ah 44 SHS1000 Series SIGLENT Making DC and AC Voltage Measurement Table 3 1 DC and AC Function Menu Save the current input value as a reference and record again Real value equals relative value plus measurement value of Resa saeta Ao Soos the best measurement scale Ano Soe a Relative Value Manual Choose measurement scale manually Choose the best measurement scale Auto automatically according to the measurement Scale value will be a warring when over the scale LF DIC Oo O O 99 9mV 100 200 300 400 500 UU 600mY ALTO DEC Relative Dil Ont Auto y Trend Plot Figure 3 2 DC Voltage Measurement A lt LA O O O 196 DmV 100 200 300 400 500 UU 600mY LITO Meter Relative ALY Ont Auto ry Trend Plot Figure 3 3 AC Voltage Measurement SHS1000 Series 45 SIGLENT Operation Steps Press Meter to enter multimeter mode press F1 to choose DCV ACV measurement Insert the red probe to the V Q C banana jack input and the black probe to the COM Connect the other end of probes to the power or load to be measured Turn on off
5. or the Print Key option is set to Save Figure in Save Recall menu Press the Save option button or the S div knob before inverting the USB Flash Drive to the USB Host port will appear this information on the screen Record Wave Success This message will appear when you finish recording waveforms 62 SHS1000 Series SIGLENT Troubleshooting 1 After the Handheld Digital Oscilloscope is powered on the screen remains dark please do as following steps 1 2 3 4 Check the power cable s connection Ensure the power switch is turned on After the inspections above restart the Handheld Digital Oscilloscope If the Handheld Digital Oscilloscope is still not used after the checking please connect with MY company If there is no signal wave in the screen after gathering the signal please do as following steps 1 2 3 4 9 Check the probe connecting with the signal cable or not Check the signal cable connecting with the BNC connector or not Check the probe whether connect with the goods tested or not Check the tested goods produce the signal or not Gather the signal again The value of the tested voltage is 10 times higher lower than the real one please do as following steps Check the attenuation quotient whether match the probe attenuation proportion or not Display the wave but not steady please do as following steps 1 2 3 Check the signal s
6. to choose Record mode Use up and down arrow keys to set Interval and End Frame Press F5 to perform waveform recording Waveform Play Back Application Example Operation steps 1 2 3 Press F1 to choose Replay mode Press F5 to enter the second page of the menu Set replay Start Frame Curr_frame End Frame and return to the first page of the menu Set Replay Mode Interval and press F2 to perform waveform replay Press F1 to choose Off mode to exit waveform record Pos 6 48 ps CHi TAHU EEE A RECORD Mode SOUFCE Interval EndFrame Operate Figure 2 68 Waveform Record RA PPP bbb bb yet PPP AN A M Pos 88 ps CHi 208 060 M5G 8ps CHI 8 88mi RECORD Mode Operate Play Mode Mensal Met Pace Figure 2 69 Waveform Play Back SHS1000 Series 43 SIGLENT Chapter 3 Using the Multimeter About this Chapter This chapter provides a step by step introduction to the multimeter functions of SHS1000 series Handheld Digital Oscilloscope The introduction gives basic examples to show how to use the menus and perform basic operations The digital multimeter provides the following functions making DC voltage AC voltage resistance diode continuity capacitance DC current and AC current measurements Notes 1 You should use the multimeter with correct connections as instructions 2 Thekey Rub Stop can hold the screen 399 68 TY DC lt i 4 _O O
7. 100mv div 0 2div 2mv DC Measurement Accuracy 3 X reading offset 1 of offset All Gain Settings gt 100mv div 0 2div 100mv lt 3 5ns SHS1102 lt 5 8ns SHS1062 Math Operation E FFT Window Modes Hanning Hamming FFT Blackman Rectangular Rise Time BNC value Sampling points 1024 Bandwidth Limit 20MHz 3dB SHS1000 Series 67 SIGLENT Horizontal System Real Time Sampling Single channel below 50ns div 1GSa s double Rate channel 500MSa s Equivalent Samplin quivalen ampling 50GSa S Rate Measure Display Modes MAIN WINDOW WINDOW ZOOM SCAN X Y Time Base Accuracy 50ppm measured over 1ms interval 2 5nS div 50S div SHS1102 Horizontal Scan Range 5 0nS div 50S div SHS1062 Scan 100mS div 50S div 1 2 5 5 order Tri Level hal Ve CH1 CH2 6 divisions from the center of the screen Trigger Pre trigger Memory depth 2 sampling Displacement Delay Trigger 268 04 div Holdoff Range 100ns 1 5s Edge Trigger Edge type Rising Falling Rising and Falling Trigger Modes gt lt Positive Pulse Width gt lt Pulse Width Trigger Negative Pulse Width Pulse Width Range 20ns 10s Support Signal Formats PAL SECAM NTSC Video Trigger Trigger Conditions odd field even field all lines pointed line gt lt Positive slope gt lt Negative slope Slope Trigger a Time 20ns 10s CH1 trigger types Edge Pulse Video Slope Alternative Trigge
8. L 5 a z A I 1 h M25Gns5 gt gt CHLZAGGml FILTER Type Lpp_ Limit o EE O Figure 2 5 Before Turn On the Digital Filter SHS1000 Series 9 SIGLENT M 25 6n5 ilter Type A Est Figure 2 6 After Turn On the Digital Filter Scope s Function Menu The button Scope includes the following functions Figure 2 7 Scope Function Menu Acquire Signals System Press Scope and choose Acquire to enter acquiring system See Figure 2 8 Sampling P eak Detect MiSs UAT ACQUIRE Acquisition Averages Gins ode Sa Rate Average CG Sirc RealTime Ass Figure 2 8 Acquire Signals system function menu 10 SHS1000 Series SIGLENT Table 2 5 Acquiring Signals System Function Menu Sampling Sample and display most waveforms accurately Acquisition Peak Detect Detect burr and reduce fake wave phenomena Reduce random and irrelative noise Averages Aah Select the times of averages V JS 164 128 256 l Use sin interpolation Sinx x Use liner interpolation Equ time Set the Sampling mode to Equ time Real time Set the Sampling mode to Real time SaRate _ Display system sampling rate Sampling To construct the waveform the scope samples the signals in equal interval Peak Detect The scope captures the maximum and minimum values of the signals in every interval to display the waveform Average The scope acquires several wavefo
9. power input port 2 SHS1000 Series MHz 168 GALET Lee ad ee se SIGLENT Handheld Digital Oscilloscope _ 4 MENU Run Stop Figure 1 3 Side Panel SIGLENT CHi 2080 CH2 ABUH MibBps CHLALFEU __ o E JE 5 m m CHI lt Coupling By Limit volts Probe gt Next Page mg r coarse A 14 13 12 Il 10 Figure 1 4 User Interface Description 1 Trigger state Armed The scope is acquiring data of pre trigger please ignore all triggers under this state Ready The scope has sampled all pre triggers data and is ready to accept trigger Trig d The scope has found a trigger and is sampling data after trigger Stop The scope stops sampling data Auto The scope is sampling waveform without trigger under automatic mode Scan The scope samples and displays waveform under scan mode Shows location of current waveform in the memory 3 Shows the trigger position in the memory 4 Y Print Key option chooses to print figure Print Key option chooses to save figure 5 E USB Device option chooses to connect computer amp USB Device option chooses to connect printer 6 Shows power state 12 B shows the BW limited is on 7 Shows current time 13 Channel s vertical range 8 Horizontal position 14 Channel s coupling states 9 Frequency Counter 15 2 is a symbol of channel 2 10 Shows the trigger level 16 1 is a symbol of channel 1 11 Shows the time base 17 T shows
10. waveform Record Figure 2 65 Waveform Record Menu SHS1000 Series 41 SIGLENT Table 2 42 Waveform Record Menu Record Set recorder function menu d Set replay function menu Turn off waveform record menu Source Choose recorder source Interval A Set interval of recorder waveform End Frame Set the max value of recorder frame Operate m stop Stop recording hode Operate Plav Mode Merval next Pace Figure 2 66 Waveform Play Back Menu 1 Table 2 43 Waveform Play Back Function Menu 1 Play Back Set the Play Back function menu P Run Press to start playback playing Operate er Press to stop playing Set circular play mode Play Mode peer pay Set single time play mode Next Page Y 1 2 Enter the second page of the menu Start Frame Currtrame End Frame Mest Pace NS A 9 aaa Return Page 3 2 1 ar Figure 2 67 Waveform Play Back Menu 2 Table 2 44 Waveform Play Back Function Menu 2 Set start frame Select current frame to be played Set end frame Start Frame Curr Frame End Frame Wd Press to return the waveform recorder main Return menu Return to the first page of Play Back function 42 SHS1000 Series SIGLENT Waveform Record Application Example Operation steps 1 2 3 4 5 G Input a waveform to be recorded Press User to enter utility system Press F5 to enter the third page of the menu and enter waveform recording menu Press F1
11. 0V input with 10 1 probe 5 7 inches color TFT LCD It provides maximal bandwidth 100MHz real time sample rate 50GSa s memory depth 2Mpts The multimeter display resolution is 6000 points and can measure voltage current resistance capacitance diode continuity Support scope measure parameters trend plot multimeter measure parameter trend plot and scope waveform recorder 3 types of trigger mode auto normal and single 5 types of trigger function edge pulse video slope and alternative 32 types of auto measurement function and 3 types of cursor measure mode 4 kinds of digital filter mode FFT IV SHS1000 Series SIGLENT Unique digital filter function and waveform recording function 2 groups of reference waveform 20 groups of common waveform 10 groups of setting inside save recall Support waveform setting CSV and bitmap file save and recall with USB flash driver Accessories of SHS1000 A Quick Start A product guaranty card A certification Two 10 1 probes An USB cable A Probes calibrated device 4 O O O O O 6 A CD including EasyScope3 0 computer software system SHS1000 Series V SIGLENT Contents Safety Intormationh kasi sasa aaa A GAGAK a od II Introduction of SHS1000 Series Handheld Digital Oscilloscope ooooooooo 00 IV Function Characters iii lc IV Accessories SAS IDU a ia V Chapt r TACCIJEN Cena sinc ENENG AS GENE TA 1 Ac
12. 7 SIGLENT Operation steps 1 Press Meter to enter multimeter mode press F1 to choose Continuity measurement 2 Insert the red probe to the V Q C banana jack input and the black probe to the COM Connect the other end of probes to the object to be measured 3 When the measured object is under 50 the multimeter will alarm and read value 4 When the measured object is above 50 the multimeter will not alarm and read value Making Capacitance Measurement i O O 0 122 6HF Tl gt gt gt 100 200 300 40 uF Meter Relatie Cap Ont Trend Plot Figure 3 7 Capacitance Measurement Operation steps 1 Press Meter to enter multimeter mode press F1 to choose Cap measurement 2 Insert the red probe to the V Q C banana jack input and the black probe to the COM Connect the other end of probes to the measured object 3 Turn on off the relative according to the real demand 4 Read measurement value 48 SHS1000 Series SIGLENT Making DC and AC Current Measurement DC lt re Oo O O 214 0mA 100 200 300 400 lt Ss 600mMA O Meter Relative DC Ort Auto m Trend Plot Figure 3 8 DC Current mA Measurement DC F nga AN O 6 O dA SILA L 2 024A uman gt gt gt gt gt 1 UU 4 2 3 4 amp BA Meter Felative DC Ort Manual A Trend Plot Figure 3 9 DC Current A Measurement AC E fea O O 4 64mA m
13. 7 SIGLENT Utility System Press User to enter utility system menu See figure 2 57 TET Soung Counter Language next Page JHA Fijet Figure 2 57 Utility System Menu 1 Table 2 36 Utility System Function Menu 1 System Displays the main information of the SHS1000 Status o H Open the key press voice Sound pos Close the key press voice On Off Turn on off the frequency counter Simplified Chinese English Traditional Chinese Arabic Language French German Russian Select the interface language Spanish Portuguese Japanese Korean Italian Next Enter the next page of the Page menu Table 2 37 Utility System Function Menu 2 Option __ Screen Test Run the screen detect program Keyboard Test Run the keyboard detect program SHS1000 connects to the printer through USB cable When you execute print function please select Printer At this time the print icon displays on the top of the screen Printer USB Device SHS1000 connects to the computer through USB cable When you execute EasyScope software please select Computer At this Computer time the computer icon displays on the screen Next Page Page 2 4 Enter the third page of the menu 38 SHS1000 Series SIGLENT LISA Device Mest Page Do Do Page 2 4 Figure 2 58 Utility System Menu 2 Do Do Print E Mext Page calf Cal Page 34 Figure 2 59 Utility System Print Setup Mest Page Page 34 Figure 2 60 Utility System
14. CH1 CH2 set CH1 or CH2 as a trigger source F Trigger on rising edge of the trigger signal Trigger on falling edge of the trigger signal Slope 1 Trigger on rising and falling edge of the trigger signal absence of a valid trigger This mode allows an un triggered scanning waveform at 100 ms div or Use this mode to let the acquisition free run in the Auto slower time base settings Use this mode when you want to see the valid Normal trigger waveforms only the scope will not acquire Nora waveform until satisfied trigger The setup detects a trigger and acquires waveform then stop Setting Wu Enter the Trigger Setup Menu Coupling Holdoft Holdaff DC Figure 2 38 32 Trigger Setting Function Menu 26 SHS1000 Series SIGLENT Table 2 21 Trigger Setting Menu DC k signals below 170Hz above 140kHz LE Reiect Blocks the DC component and attenuates the l low frequency components below 7 kHz Hold off Using the arrow keys to adjust hold off a time sec the hold off value is displayed Hold off Reset hold off time to 100ns Reset Return the first page of the menu HAHA F LLIT T T T T T 111111111 M SHGn Type SOUrCE Slope Moge Edge Auto Figure 2 39 Signal Rise Trigger Menu SHS1000 Series 27 SIGLENT Pulse T
15. ENT AC Voltage 1 15d 1 5digit 1 5digit 10pF eer ne n 400nF 100pF a 4 5digit 400uF 100nF DC Current 1 5digit 600mA 100uUA 1 5 5digit ee A range measure periods10 seconds interval period215 minutes 70 SHS1000 Series SIGLENT AC Current 1 5digit 600mA 100uA 1 5 5digit A range measure period lt 10 seconds interval period215 minutes Recorder Specifications In total 7M original points Single channel 7M Double channel each 3 5M Scope Trend Plot Display Mode full view and normal Record Length 800K points gt 24 hours Record Channel 5 Num Record Channel 1 kenaa Ang Safety Designed for measurements on 1000 V Category II Installations 600 V Category III Installations Pollution Degree 2 per ANSI ISA S82 01 1994 EN61010 1 1993 IEC1010 1 e CAN CSA C22 2 NO 1010 1 92 UL3111 1 SHS1000 Series 71 SIGLENT MAX INPUT VOLTAGE Vrms CAT II SCOPE CHANNEL CATIII PEEP INPUT CH1 CH2 T A KANG pi tT TN TTT pt ttt NT yy 0 01 0 02 0 05 0 1 0 2 0 5 1 2 5 10 20 50 gt FREQUENCY MHZ Maximal Input Voltage VS Frequency Notes Overvoltage Category III refers to distribution level and fixed installation circuit inside a building overvoltage Category II refers to local level which is applicable for appliances and portable equipment MAX COMMON MODE VOLTAGE Vrms 1000 pt ttt ee IIA TI
16. HS1000 Series SIGLENT free run in the absence of a valid trigger This mode allows an un triggered scanning waveform at 100 ms div or slower time base settings Use this mode when you want to see only valid triggered waveforms when you use Normal this mode the oscilloscope does not display a waveform until after the first trigger When you want the oscilloscope to acquire Single a single waveform press the SINGLE button Next Page Page 2 2 Return to the first page of slope trigger Alternative trigger The trigger signal comes from two vertical channels when you use alternative trigger In this mode you can observe two irrelative signals at the same time You can select different trigger types for two vertical signals and selected types cover edge pulse video and slope trigger Trigger information of two channel signals display on the bottom right of the screen Type Source Mode Slope Alternative Edge Set Up Figure 2 48 Alternative Trigger Menu Table 2 28 Slope Trigger Function Menu 2 The trigger signal comes from two vertical channels Type Alternative when you use alternative trigger In this mode you can observe two irrelative signals at the same time B Etres CHX Set trigger type information for CHX signal CHY Set trigger type information for CHY signal Set trigger type of the vertical channel signal to Edge K Triggering on rising edge Slope Triggering on falling edge t Triggering o
17. HS1000 Series 51 SIGLENT Oscilloscope Trend Plot 1 2 3 4 Time 6 81 ETTTTTTTTTTTT 9 Faoi H E E A ik MAA 8 Jl WN A AA va TAN TANG GN TAN PA panel ek cT 40 00rr1 1 9 A I 8 t 100 00m1 W LL 7 4 5 HAm rG Be TrendFlot Parana Pararn 8 Mest Page CHI pp CHI inax Page 12 Figure 4 1 Scope trend plot user interface current recorded time the percentage of recorded date take in the whole memory Value of the latest recorded data point A Value of the latest recorded data point B real time sampling time of the cursor point parameter measurement of the cursor point vertical scale vertical scale D 799 X E TrendFlot Params Pararn B Mest Page CHI pp CH1 inax Page 12 Figure 4 2 Scope Trend plot Function Menu 1 Table 4 1 Scope Trend plot Function Menu 1 uilt the current data and start to Trend Plot Restart 3 record afresh Run Stop H Stop or continue recording data Next Page Page 1 2 Enter the second page of the menu 52 SHS1000 Series Choose the parameter Voltage time and delay Parameter A B to be measured measurement SIGLENT Manual Mest Page Figure 4 3 Scope Trend plot Function Menu 2 Table 4 2 Scope Trend plot Function Menu 2 Display the data up to the minu
18. Menu 3 Table 2 38 Utility System Function Menu 3 Update You can update the SHS1000 by using USB flash ELA Record __ Press this button to enter the waveform record menu Screen saver Mest Page amir Page 4 4 Figure 2 61 Utility System Menu 4 Table 2 39 Utility System Function Menu 4 1min 2min 5min 10min Screen saver 15min 30min Set the time of screen saver hour 2hour 5hour Off Date Time Lo Set the date and time of the SHS1000 Next Page Page4 4 Return to the first page of the menu SHS1000 Series 39 SIGLENT Self Calibration Self Calibration is operated to calibrate the relative data of SHS1000 to decrease the mistake during the measure If the operating temperature changes by or more than 5 C or the instrument runs more than thirty minutes you should do the self calibration When you do the self calibration you should cut off all the probes and leads Then press User button to choose Do self cal to show the self calibration menu and do self calibration program according to the prompts on the screen Disconnect Everything from All Inputs Doing CH2 Cal 2856 Figeure 2 62 Self Calibration Print Setting The SHS1000 supports PictBridge compatible printers You can connect the side USB Device of the SHS1000 to the USB Device of the PictBridge compatible printer through USB cable After setting the print settings press Save Recall button for 4 seconds to complete the prin
19. Pulse Width Mode Coupling Source Polarity Standard Mode Source Condition Time Mode Source Mode Coupling Slope A A A A A lt lt lt lt lt lt O jo O O O D D 0 D D D No 1 CH1 J Z J J mio OJO O O O Le 7 O O 2134 3 313 7 O Computer CH1 Rising Auto 0 00V Pulse CH1 1 00ms Auto Video CH1 Normal All Lines Auto Slope CH1 1 00ms Auto Alternative CH1 Edge Rise SIGLENT Appendix C Battery Installation The battery of the SHS800 is separated from it s host please install the battery according to following steps Dismantle the two screws of the battery cap by using screw knife as figure 1 shows 2 Draw back the packing block of the Handheld Digital Oscilloscope and then dismantle the battery cap as figure 2 shows 3 Put battery into the battery bin stably as figure 3 shows 4 Cover the battery cap and tightly twist the two screws which are dismantled from the battery cap forward such as figure 3 shows 5 Successful installation of the battery depends on whether the Handheld Digital Oscilloscope could be normally turned on or not Notes The battery plug is designed to prevent from connecting reversely it prefers operating slightly to powerfully Make a caution at the direction of the battery cap logo of the battery is attached to the external end If The Handheld Digital Oscilloscope can not be turned on normally after corre
20. User Manual SHS1000 Series Handheld Digital Oscilloscope UM03010 E07B SIGLENT Declaration Copyright SIGLENT TECHNOLOGIES CO LTD All rights reserved Contents in this manual are not allowed to copied extracted and translated without permission by the company SHS1000 Series I SIGLENT Safety Information Carefully read the following safety information before using the SHS1000 Specific warning and caution statements where they apply appear throughout the manual A Warning identifies conditions and actions that pose hazard s to the user A Caution identifies conditions and actions that the user should notice The following international symbols are used on the SHS1000 and in this manual A A Hazardous Protective Warning Earth Ground Power Voltage Earth Ground Switch Use only insulated voltage probes test leads and adapters supplied with the SHS1000 or accessories appointed by the company 4 Before use inspect voltage probes test leads and accessories for mechanical damage and replace when damaged Always connect the battery charge first to the AC outlet before connecting it to the SHS1000 Do not apply voltages that higher than 600 V from earth ground to any input when using scope ports in a CAT environment Do not apply voltages that higher than 1000 V from earth ground to any input when using scope ports in a CAT environment Do not apply voltages that hi
21. V IT T IS L A tt tt A tit ttt 0 01 0 02 0 05 01 02 05 1 2 5 10 20 50 100 200 gt FREQUENCY MHZ 72 SHS1000 Series SIGLENT Safe Handling Maximal Input Voltage Between Scope Reference and Between Scope Reference and Multimeter Reference MAX INPUT VOLTAGE Vrms 1000 Ol 02 0 5 1 2 5 10 20 50 100 200 gt FREQUENCY MHZ Maximal Voltage From Probe Tip to G round and From Probe Tip to Probe Reference MAX VOLTAGE FROM PROBE REFERENCE TO GROUND 1000 5 10 20 50 0 01 0 02 0 05 0 1 0 2 0 5 1 2 100 200 gt FREQUENCY MHZ Safe Handling Maximal Voltage From Probe Reference to Ground SHS1000 Series 73 SIGLENT Generic Specification Display System Color TFT 5 7 inches 145mm diagonal Liquid Crystal Display Resolution 320 horizontal pixels 234 vertical pixels Display Mode Display Color Display Contrast typical Backlight Intensity typical Wave Display Mods Menu Display Off 1 min 2 min 5 min 10 min 15 min 30 min 1 hour 2 hour 5 hour Skin Classical Modern Traditional Succinct waveform Interpolation Sin x x Linear Color model Normal Invert Screen Saver Simplified Chinese Traditional Chinese English Language Arabic French German Russian Spanish Portuguese Japanese Korean Italian Input Voltage 100 240 V 50 60Hz Adapter Supply Auer Power a 9V 4A Voltage Battery Supply Power 5000mAh 7 4VDC persisting about 4 hours Chargin
22. ase contact with the nearest SIGLENT sale and service office Except this summary or the applicable warranty statement SIGLENT makes no warranty of any kind of express or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose In no event shall SIGLENT be liable for indirect special or consequential damages Contact SIGLENT SIGLENT TECHNOLOYIES CO LTD Address 3 F No 4 BUILDING 3rd LIUXIAN Rd ANTONGDA INDUSTRY GARDEN BAO AN DISTRICT SHENZHEN 518101 CHINA Tel 0086 755 36615186 E mail sales siglent com http www siglent com SHS1000 Series 65 SIGLENT Appendix A Specifications All specification applies to 10X attenuation switch setup probe and SHS1000 series Handheld Digital Oscilloscope To verify if he SHS1000 meets with the specifications it must meet the following conditions first The oscilloscope must have been operating continuously for thirty minutes within the specified operating temperature You must perform the Do Self Cal operation accessible through the User menu if the operating temperature changes by or more than 5 C The SHS1000 must be within the factory calibration interval The SHS1000 should be calibrated once every year All specifications are guaranteed except those noted typical Oscilloscope Specifications 1X 5X 10X 50X 100X 500X 1000X Overvoltage l Maximum Voltage Channels from earth ground
23. asure CH1 CH2 Set the input signal channel that the Cursor B will Cursor B NONE measure Track Mode Application Example Operation steps 1 Press Cursor Measure once to enter cursor system 2 Press F1 to choose Tracke mode 3 Adjust cursor and cursor B to trace waveform with arrow keys 1111 LE DE E il 11 CHI BAAM CURSOR Mode Cursor A Cursor H Cur A Cur Track CH1 CH1 4 Figure 2 28 Cursor Trace Menu Automatic measure mode This mode will take effect with automatic measurements The instruments will display cursors while measuring parameters automatically These cursors demonstrate the physical meanings of these measurements 20 SHS1000 Series SIGLENT Automatic Measure Application Example Operation steps 1 Press Cursor Measure once to enter cursor system 2 Press F1 to choose Auto mode 3 Press Cursor Measure again and choose parameter types to be measured e E silent MA Panel CH LABU METETE MEASURE Source Type Figure 2 29 Auto Measure Parameter Measure Press I Cursor Measure twice and any key of F1 F5 to enter parameter measurement system Figure 2 30 Parameter Measure Function Menu Table 2 14 Parameter Measure Function Voltage Press this button to enter the Voltage measure menu Press this button to enter the Time measure menu Delay Press this button to enter the Delay measure menu All Mea Press this button to enter
24. ave Go to the Save Recall interface Print Ke y Save Picture Saving CSV Twpe Data Depth Para Save Figure 2 54 Saving CSV Menu Table 2 34 Saving CSV Function Menu Option Setting Introduction Maximum Set to store maximum waveform data to CSV file save Soto the SavelRecallinterface _______ Recall Factory Setups Press Recall you can recall factory setups Table 2 35 Factory Setups Function Menu To view the Factory setup Recall the Factory setup Save Recall Waveform to USB Flash Drive Application Operation steps 1 Press Save Recall and press F1 Type to choose Waveforms 2 Insert USB flash drive to USB host you will get the message USB flash driver connects successfully 3 Press F2 Save to to choose File 36 SHS1000 Series SIGLENT 4 Press F4 Save to enter save recall interface 5 Press F1 Modify to choose File 6 Press F2 New File and input the mane of the file according to the prompts to create a new file Then press Confirm Figure 2 55 Input the Name of the File 7 File saves successfully Modify Mest Page Figure 2 56 File Saves Successfully Recalling a file Choose the file to be recalled and press Recall at the memory interface which you complete the recalling operation Notes The picture in the SHS1000 with a BMP postfix can t be recalled but you can open it in computer with relative software SHS1000 Series 3
25. ay Mest Pace Figure 2 18 FFT Function Menu 2 Table 2 10 FFT Window Function Window Characteristic Advantage content Rectangular The best frequency resolution but the worst magnitude resolution It is essentially the same as no window Better poorer accuracy rectangular frequency magnitude than Hamming has a slightly better frequency resolution than Hanning Best magnitude resolution but worst frequency resolution Symmetric transients or bursts Equal amplitude sine waves with fixed frequencies Broadband random noise with a relatively slowly varying spectrum Sine periodic and narrow band random noise Transients or bursts pulse The ranges of the signals have great difference from before to after Single frequency waveforms to find higher order harmonics SHS1000 Series 15 SIGLENT FFT Zoom zoom in FFT waveform vertically by 1X 2X 5X and 10X Scale choose dBVrms or Vrms as a measure unit Display Spilt or Full Screen FFT waveform display mode FFT Waveform Operation Application Example Operation steps 1 Input a signal to CH1 and press Auto Press Scope and choose Math to enter waveform operation Press F1 to choose FFT Press F5 to enter the second page of the menu and adjust the setups Adjust the channel vertical scale and complete FFT waveform s vertical position and vertical scale settings 6 Press F5 to exit waveform operation LI I nizle
26. cidence of the Front Panel and User Interface oooccccccccncnnnnnnononononananononononcccnnnnns 1 SA A A A A lat bees 4 A A O A E 4 Chapter 2 USING the CODO ii diia 6 Menu and Control Buttons iii ii ida 6 Automatic Seting Sia al 7 GAT CHZ hanneliFUNCIOAS sa kaa aa ind ir 7 SEOPES FUNCION Menard ete 10 Acquire Signals SYSTEM aaa aa ica 10 BISHI oy SEM san aaa ia A a o 12 Math WV o A AU D aga Da aan naa ani kaa AL A aaa Ac aL NZ ana a 0 A ana 14 FlorIZontal SysSten 2a 0420 aa NA A A Ad 16 Reference waveform cccccccccccccicicccecscsssssoccocecocasssssssssnsonoooooooonenenanses 18 Cursor and Measure SysSteM coccccncccnnncnnnnnnnnnncoccconnnnnnnonnnnnnnnnonnnnnnonococononnnnnnnnnnonannnnnnnnnnnos 19 CUrSO Mes rt ida 19 Parameter Measure ninia ia 21 THOGEr SYSTEM AAA AAA A A 26 Save and Recall SM AAA AAA 34 TY SS a ads 38 Chapter 3 Using the MUMete asocia ias 44 Making DC and AC Voltage MeaSureme n ccccceeeeeeeceeeeeeeeeaessssessseeeseseeeeeeseeeeeaaaas 45 Making Resistance M aSUureMe nt cccccccccccccceececccccccsesnsssseeccccceeeeaeesseseeeaeensseseeceeseaaas 46 Making Diode Measurement occcccccnooononconnnononorocococcnnnononaconococnonanorocoronnnnnnnnanicnococnnnnnos 47 Making Continuity Measurement cccccccccccccccicccciicccccccicccccccccccscscsssanaeaeas 47 Making Capacitance MeasureMent occcc
27. ctly installation it is likely that the battery quantity of electricity has been used off please refresh for the battery right away In the case of not working battery must be charged once every three months Figure 3 SHS1000 Series 77 SIGLENT Appendix D Daily Maintaining and Cleaning Daily Maintaining Do not let the LCD exposed in the sun directly for a long period when storing or placing the SHS1000 CAUTION To avoid damage to the instrument or probes do not expose them to sprays liquids or solvents Cleaning If this instrument requires cleaning disconnect it from all power sources and clean it with a mild detergent and water Make sure the instrument is completely dry before reconnecting it to a power source To clean the exterior surface perform the following steps 1 Remove loose dust on the outside of the instrument and probes with a lint free cloth Use care to avoid scratching the clear plastic display filter 2 Use a soft cloth dampened with water to clean the instrument Use an aqueous solution of 75 isopropyl alcohol for more efficient cleaning Note To avoid damage to the surface of the instrument or probes do not use any abrasive or chemical cleaning agents 78 SHS1000 Series
28. d data automatically 58 SHS1000 Series SIGLENT Stop record data Next Page Page1 2 Enter the second page of the menu Manual Mest Page Figure 4 14 Multimeter Trend Plot Menu 2 Table 4 7 Multimeter Trend Plot Function Menu 2 Waveform Data in the memory transferred to the storage exterior storage device Off Record data automatically n O Record data manually A Record presses a record Return to the multimeter function state Next Page Page2 2 Return to the first page Record manually Multimeter trend plot application example Start plot function Operation steps 1 Input a measured signal correctly See chapter 3 Using the Multimeter 2 Press F5 to enter Trend Plot at the multimeter main menu The SHS1000 will record the measurement value of the input port continuously and plot measurements over time t Time 6 8G6 59 196 0 Pm Agee E 116 LILI y L EM Sea a eae ee ee eee Se Se SS SS SS SS SSS SS AA AA A AA A An an oe oe 363 8m10 00 29 006 60 61 14 8 06 47 TrendPlot SaRate Met Page Figure 4 15 Multimeter Trend Plot Recording Curve 3 Press F4 to stop or run recording data 4 At the second page of the menu you can choose manual or auto mode to record the data SHS1000 Series 59 SIGLENT Display the record data 5 Press F3 to choose data display mode Normal mode the screen displays the data up to the minute The recorded data before saved in the memor
29. ding icon and measure value of your selected Delay measure parameter M MYL MA Return Return to the home page of MEASURE menu All parameters measure source Voltage Time Delay on Return Figure 2 34 All Measure Function Menu Table 2 18 All Measure Function Menu CH1 Select input signal channel Voltag On Off Turn on off the all voltage parameters measure function On Off Turn on off the all time parameters measure function Turn on off the all dela arameters measurement Delay On Off Mi function Return Return to the All Measure main menu Table 2 19 All Measure Function Menu Measure Type Introduction Tu Vmak The positive peak voltage g The negative peak voltage EID The absolute difference between positive peak voltage and negative peak voltage ERPE Vtop The maximal voltage during the measure The minimal voltage during the measure The difference between the Vtop and the Vbase voltage The arithmetic mean over the first cycle of the waveform SHS1000 Series 23 SIGLENT The arithmetic mean over the entire waveform Virtual value the true Root Mean Square voltage of the first cycle in the waveform PPO The true Root Mean Square voltage over the entire waveform Defined as Vmax Vhig Vamp after the waveform rising Defined as Vmin Vlow Vamp after the waveform falling Defined as Vmin Vlow Vamp before waveform rising Defined as Vmax Vhig Vamp bef
30. e waveform save recall interface 34 SHS1000 Series SIGLENT Saving waveform Saving waveform to device Twpe SaveTo Waveform Figure 2 51 Saving Waveform to Device Menu Table 2 31 Saving Waveform to Device Function Menu Menu for the Storage Recall waveforms in the Type Waveforms scope Save waveforms to the SHS1000 s internal save To Device memory No 1 to Choose the position number to save recall setups O Save _ Accomplish the storage Recall _ Recall the storage in the waveform operation Saving waveform to USB Flash Drive Type cave TO Figure 2 52 Saving Waveform to USB Flash Drive Menu Table 2 32 Saving Waveform to USB Flash Drive Function Menu Option Setup Introduction save Accomplish the storage Saving Picture Waveform interface image can be saved to USB flash drive but they can t be recalled You can view them on correlative computer software Type Print Ker NE Save Picture Figure 2 53 Saving Picture Menu SHS1000 Series 35 SIGLENT Table 2 33 Saving Picture Function Menu l Menu for the Storage Recall waveform interface Type Picture mage l l Choose Print Picture option and press Print Picture Save Recall for 4 seconds to print the picture while the SHS1000 connects to the printer Choose Save Picture option and press Save Recall for 4 seconds to save the picture while you insert an USB flash driver to the SHS1000 S
31. easured item 2 Make sure that if the multimeter is beyond the calibration date if the measurements and the real values are beyond the relevant precision please contact with the calibration site warranted by SIGLENT company to calibrate the SHS1000 3 If you cant use the SHS1000 normally all the same please contact with SIGLENT servicing center we will provide service for you 9 The other kind of trouble please contact with SIGLENT servicing center For more details please see service and support Warning person without warranty by SIGLENT Company shouldn t disconnect the machine for inspection or you will lose the quality guarantee 64 SHS1000 Series SIGLENT Chapter 6 Service and Support About this Chapter This chapter covers basic maintain procedures that can be performed by the user You should have a detailed understanding of the content below to use and maintain you legal rights Maintain Summary Each SIGLENT product is warranted to be free from defects in material and workmanship under normal use and service The warranty period is three years and begins on the data of shipment This warranty extends only to the original buyer or ender user c of a SIGLENT authorized reseller If a product or CRT proves defective within the warranty period SIGLENT will provide repair or replacement as described in the complete warranty statement To arrange for service or obtain a copy of the complete warranty statement ple
32. erence Waveform Cursor and Measure System Cursor measure Press Cursor Measure once to enter the cursor measure system There are three modes of measure manual track automatic Manual mode horizontal or vertical cursors appear in couple and we use them to measure voltage or time parameters The space between two cursors can be adjusted ode Type source Cura Cur B Manual CHI Figure 2 26 Manual Cursor Measurement Table 2 12 Manual Mode Function Menu In this menu set the manual cursor Cursor Mode Manual measure Use cursors to measure voltage Voltage Type Ti parameters ime l Use cursors to measure time parameters CH1 CH2 Choose the signal to be measured by Source MATH REFAREFB Cur A Use arrow keys to adjust t position of cursor A Cur B Use arrow keys to adjust t position of cursor B SHS1000 Series 19 SIGLENT Track mode In this mode the screen displays two cross cursors The cross cursor sets the position on the waveform automatically You could adjust cursor s horizontal position on the waveform by turning the arrow kyes The oscilloscope displays the values on the top of the right screen Mode Cursor Cursor B Cura Cur B Track CH1 CH1 4 Figure 2 27 Cursor Trace Menu Table 2 13 Trace Mode Function Menu Cursor Mode Track In this mode set track cursor measure CH1 CH2 Set the input signal channel that the Cursor A will Cursor A NONE me
33. g edge of source 1 and the last falling edge of source 2 24 SHS1000 Series SIGLENT Parameter Measure Supplication Example Operation steps 1 H Press Cursor Measure twice and any key of F1 F5 to enter parameter measurement system Choose any key out of F1 F5 to choose measure type For example Voltage Press F2 tochoose measure parameter For example Vpp Press F5 to return CH1 A MEASURE CH1 CHI IH1 Y min Freg qa oo HALH gt Figure 2 35 All Measure Function Menu 32 types of parameters measure application example Operation steps 1 En Input two sine signals respectively to CH1 and CH2 with the same frequency amplitude and different phases Adjust time base and vertical scale to obtain the best waveform Press Cursor Measure and choose All Turn on Voltage Time Delay and will display 32 types of parameter measure _ FRR P45 6 sl ps FEF 250 ave LBR 4 25ms _ _ AN Eg CHi FAAAM MEASURE SOUrCe voltage Time Delay Oon on on on Retum Figure 2 36 32 Types of Parameter Measure SHS1000 Series 25 SIGLENT Trigger System There are 5 kinds of trigger function edge pulse video slope alternative Press Trigger to enter the trigger system Edge Trigger Type Source Slope Mode Edge Auto Set Lip Figure 2 37 Edge Trigger Function Menu Table 2 20 Edge Trigger Function Menu Trigger on the rising or falling edge of the input E
34. g time About 4 hours Environments Work 0 40 C Storage 20 C 70C Cooling Forcing it cold with a fan Humidity 85 RH 40 C Height 3000m Temperature 259 5mm Dimension 163 2mm 53 3mm 74 SHS1000 Series SIGLENT Appendix B Default Setup Menu or Options Knobs or Buttons system Default setup U O Coupling BW Limit Volts div Probe Invert Filter Volts div Operation CH1 Invert CH2 Invert FFT Operation Source Window FFT Zoom Scale Off Coarse CH1 CH2 Off Off 1 00V CH1 CH2 O gt MATH Hanning X F dBVrms Split Main Time Base 0 00us 500us 50 0us Level Off CH1 3 2divs 5divs Sampling Display Window Position Sec div Window Zone HORIZONTAL Trigger knob Type Source CURSOR Horizontal voltage Vertical time Three Mode Options ACQUIRE gt Averages Sampling Method Real Time Type Vectors Persist off Gird Intensity DISPLAY 60 Brightness 40 Format Menu Display Infinite Setups O A lt lt A UN a Z O O UN O O UN SAVE RECALL Save To Device 75 SIGLENT UTILITY TRIGGER Edge TRIGGER Pulse TRIGGER Video TRIGGER Slope TRIGGER Alternative 76 SHS1000 Series Setup Source REFA REFB Sound Frequency Counter USB Device Record Source Slope Mode Coupling Level Source Condition Set
35. ger F3 to set pulse trigger conditions F4 and use arrow keys to set pulse width Move trigger level line with the up and down arrow keys lt will trigger as soon as it meets the trigger conditions 1 2 Press 3 Press 4 Press 5 Press 6 Notes We can t adjust trigger level line under the SetWidth menu as we use the up and down arrow keys to set both the pulse width and trigger level line If you want to adjust the trigger level please make sure that you have exited the SetWidth menu sigle Trig d i Sloat FE Hi kali 14 A 59 Ay 1 CH Laa 0 000A SMS CHA PEG TRIGGER Type Source E nest Pace Pulse Ea Figure 2 42 Pulse Trigger SHS1000 Series 29 SIGLENT Video Trigger Type Source Polarity Sync Met Page Video All Lines Figure 2 43 Video Trigger Menu 1 2 24 Pulse Trigger Function Menu 2 Setting instruction When you select the video type put the couple set Type Video to the AC then you could trigger the NTSC PAL and SECAM video signal Select the input source to be the trigger signal Normal triggers on the negative edge of the sync Normal Polarity ee T ven a vee triggers on the positive edge of the sync TL queres Alsa All Lines Line Num Odd Field Even Field Page 1 2 Page 1 2 Enter the second page of Video trigger menu Type Standard Mode Mest Pace Video Auto Figure 2 44 Video Trigger Menu 2 Sync Select appropriate v
36. gher than 600 V from earth ground to the isolated inputs when using scope ports in a CAT environment Do not apply voltages that higher than 1000 V from earth ground to the isolated inputs when using scope ports in a CAT environment Do not apply input voltages above the rating of the instrument Use caution when using 1 1 test leads because the probe tip voltage will be directly transmitted to the SHS1000 Do not apply voltages that higher than 600 V from earth ground to any input when using multimeter ports in a CAT environment Do not apply voltages that higher than 1000 V from earth ground to any input when using multimeter ports in a CAT environment Do not apply voltages that higher than 600 V from earth ground to the isolated inputs when using multimeter ports in a CAT environment II SHS1000 Series SIGLENT Do not apply voltages that higher than 1000 V from earth ground to the isolated inputs when using multimeter ports in a CAT environment Y Do not insert metal objects into connectors Always use the SHS1000 only in the manner specified The terms isolated is Used in this manual to indicate a measurement in which the SHS1000 input BNC or banana jacket is connected to a voltage different from earth ground The isolated input connectors have no exposed and are fully insulated to protect against electrical shock Use of the SHS1000 in a manner not specified may impair the protection provided by
37. h the probe tip to the Probe Comp 3V connector and the reference lead to the Probe Comp Ground connector Display the channel and then push button Auto 3 Check the shape of the waveform displaying on the screen Under Compensated Correctly Compensated Over Compensated 4 Please adjust your probe or repeat all the operations above if necessary 4 SHS1000 Series SIGLENT Multimeter meter pen To avoid obtaining no measurements or unnecessary damage to the SHS1000 you should use the right jack when measuring current voltage and other measure SHS1000 Series 5 SIGLENT Chapter 2 Using the Scope About this Chapter This chapter provides a step by step introduction to the scope functions of SHS1000 series The introduction gives basic examples to show how to use the menus and perform basic operations without d covering all of the capabilities of the scope functions In order to use the SHS1000 effectively we need to know the functions of the SHS1000 below Menu and control buttons connector and control auto settings Scope measurement system trigger system storage system and utility system Menu and Control Buttons Table 2 1 Function Menu 6 SHS1000 Series SIGLENT Automatic Settings When measuring unknown signals and having no idea about its voltage range frequency trigger and other information you can use the automatic setting function Automatic Setting Application Example Operating
38. hapter This chapter mainly covers the following contents Geta primary understanding of the front panel and user interface A brief function check Probe compensation Accidence of the Front Panel and User Interface You d better get an understanding of the front panel before you operate the SHS1000 series Handheld Digital Oscilloscope The following contents introduce the function of the front panel With its help you could be familiar with the operations of the SHS1000 in a short time g HSIGLENT Handheld Digital Oscilloscope 9 SIGLENT 7 Handheld Digital Oscilloscope 6 5 4 10 Auto 11 Run Stop 12 2 13 14 2 15 l 16 17 Figure 1 1 Front Panel SHS1000 Series 1 SIGLENT Description 1 power on off key 10 menu on off key 2 CH1 vertical range and position key 11 arrow keys 3 CH1 on off key 12 Auto Run Stop Cursor function 4 Scope Meter Recorder function keys menu 13 CH2 on off key 5 option keys 14 Trigger User Save Recall function 6 Handle keys 7 LCD 15 CH2 vertical range and position keys 8 LOGO 16 time base and horizon position keys 9 BW and sample rate 17 multimeter input ports Notes The arrow keys include these functions direction keys moving trigger level setting the trigger level to Zero choosing menu setting horizontal position to Zero moving Cursor ISOLATEDINFUTS a gt Figure 1 2 Isolated Inputs Channels Description 1 USB Device 2 USB Host 3
39. ideo sync Table 2 25 Pulse Trigger Function Menu 2 When you select the video type put the couple set to the AC then you could Type Video l trigger the NTSC PAL and SECAM video signal NTSC Select the video standard for sync and line Standard PAL SECAM number count Use this mode to let the acquisition free run in Auto the absence of a valid trigger This mode allows an un triggered scanning waveform at 100 ms div or slower time base settings Use this mode when you want to see only valid triggered waveforms when you use this mode Normal l i the oscilloscope does not display a waveform until after the first trigger when you want the oscilloscope to acquire a single waveform press the SINGLE button setup gt Enter the Trigger setup menu 30 SHS1000 Series SIGLENT Video Trigger Application Example Operation steps Input a video signal Press Trigger to enter trigger menu Press F1 to choose Video Press F5 to enter the second page of video trigger menu Press F2 to set the video standard PAL SECAM or NTSC meeting with the input signal Press F5 to return to the first page of video trigger menu 7 press F4 to choose the type of Sync If you choose Line Number use the up and down arrow keys to set the number of line 8 Move trigger level line with the up and down arrow keys to set the trigger position N IA O Notes We can t adjust trigger level line u
40. izer Full view mode the screen display all recorded data in the memorizer 6 Zoom function under full screen mode press time base to zoom in or zoom out 7 Data analysis move cursor analyzing data over time Time A161 24 1967 BA 5mvy ga TH a LI 1 1 me kin ee A LL LA LiL LL L 1 Li l L LI Lidl 121 9m 0 01 09 208 81 14 8 10 06 TrendPlot SaRate Mest Page Figure 4 16 Analysis Trend Plot Data 8 Save waveform save the recorded waveform to exterior storage device to make more detailed analysis 9 Press Return to exit trend plot 60 SHS1000 Series SIGLENT Chapter 5 Prompting and Troubleshooting About this Chapter This chapter gives a detailed instruction of every system prompting appears on the screen as well as some basic troubleshooting System Prompting Messages Instruction Trig level at limit Mention you that the trigger level is at a limit when you turn the Trig level knob Horizon position at limit Mention you that the horizontal position is at a limit when you turn the horizon position knob Volts Div at limit Mention you that the vertical voltage have already touched the Min 5mV div or the Max 100V div Volts position at limit The system would display this information when the vertical position is at a limit Sec Div at limit Prompts that the Volts Div is at full range while turning the vertical scale knob Holdoff time at li
41. mit Use the arrow keys when holdoff time has been to max or min value now the system will clew this information Function isn t useable Under several special modes the some functions could not be running No signal The system would clew this information when the signal could not match the auto set condition Using in the auto set Adjust at limit You could adjust the pulse width by the arrow keys till the pulse width has reached min20 0ns or max 10 0s Location Empty If you have no stored waveforms or setups on some location the screen will display this information when you press the Recall button on this location USB Flash Drive Plug In This information will appear when you invert the USB Flash Drive to the USB Host port USB Flash Drive Pull Out This information will appear when you pull out the USB Flash Drive SHS1000 Series 61 SIGLENT Store Data Success Save setup data waveform data or Figure data to the internal of the oscilloscope or USB flash successful Ready Data Success Read setup data or waveform data from the internal of the oscilloscope or USB flash successful Please set USB Device to printer Press the S div knob will appear this information on the screen when the Print Key option is set to Print Figure and the USB Device option is set to Computer USB Flash Drive isn t connected When the Save To option is set to File
42. n rising edge and falling edge Setup Enter the Trigger setup menu SHS1000 Series 33 SIGLENT Save and Recall System SHS1000 can save 2 groups of reference waveforms 20 groups of setups and 10 groups of waveforms in its internal memory There is an USB Host interface in the front panel of the SHS1000 and you can save setup data waveform data waveform interface image CSV file to an USB flash drive The postfix of setup data is SET while waveform data is DAV The waveform data can be recalled to the current SHS1000 or SHS1000 with the same the model Figure data and CSV file can t be recalled to the SHS1000 but it can be opened on the computer through correlative software CSV can be opened by EXCEL software on computer Saving Setups Saving Setups to Device All setups are stored in nonvolatile memory When recall the setups the SHS1000 will be under the setup save mode Type Save TO Setup Setups T Figure 2 49 Saving Setups to Device Menu Table 2 29 Saving Setups to Device Function Menu option Setting introduction _ _ save gt gt gt Accomplish the operation of saving setups Recall Recall the saved setups Saving Setups to USB Flash Drive Type save To Figure 2 50 Saving Setups to USB Flash Drive Menu Table 2 30 Saving Setups to USB Flash Drive Function Menu Used to save recall the SHS1000 s setup menu Save the setup data of the SHS1000 to USB flash drive Enter th
43. nction Menu Pause or contnue playing waveform automatically you can Stop Continue change the time base to observe the waveform in the memory Replay the waveform Previous Back the waveform and then play Speed the playing of the waveform Exit the replaying menu Viewer Record Replay Set Figure 4 10 Waveform Recorder Setting Menu Table 4 6 Waveform Recorder Setting Menu Record and replay channel waveform with full Full screen screen Viewer mode Record and replay channel waveform with divided Split screen The up half of the screen displays CH1 while the down half displays CH2 l Record circularly when the waveform recorder is continuous Record full the after data will cover the pre data mode Ga Stop recording data when the waveform recorder 9 memory is full When replaying the screen waveform updates By Point ee ee every dot from left to right Replay mode When replaying the screen waveform updates the By frame whole screen according to the time of sampling every frame data return Exit the recorder setup interface Waveform recorder application example Startup the waveform recorder function Under 100mS or above time base Press Recorder to open the main menu Press F2 to choose scope recorder Press F3 to set the waveform recorder Such as Press F5 to return to the waveform recorder main menu Press F1 to enter record interface Press F4 to set storage mode Interi
44. nder the Line Number menu as we use the up and down arrow keys to set both the pulse width and trigger level line If you want to adjust the trigger lever please make sure that you have exited the Line Number menu Y T Pos AAS na aga ee oe maka a enea ga aa a eae WA G IF BAHAkHz CHI Z8GmlJ M See p CHi a Hoel TRIGGER Type standard Mode Mext Page Video Auto Setup Page 22 Figure 2 45 Video Trigger SHS1000 Series 31 SIGLENT Slope trigger Ty pe Source when Time Mert Fage ETa Figure 2 46 Slope Trigger 1 Table 2 26 Slope Trigger Function Menu 1 Trigger on positive slope of negative slope Type Slope gg p p g p according to setup time of the oscilloscope CH1 Select trigger source l Select trigger conditions Time Use the arrow keys to set slope time Time Set setup range is 20ns 10s Enter the second page of the slope trigger Next Page Page 1 2 meni RD poe M Pos a agus CHI SAAM gt F EGET T i TRIGGER Type Mode Neat Page Slope Auto Set Lip Page 27 Figure 2 47 Slope Trigger 2 Table 2 27 Slope Trigger Function Menu 1 Trigger on positive slope of negative slope according to setup time of the oscilloscope Select the trigger level that can be adjusted by LEVEL knob You can adjust LEVEL A LEVEL B or adjust them at the same time Mode Auto Use this mode to let the acquisition Vertical 32 S
45. ni NINA A dr gt D Da CIN 26 GdElrms SQGRMHS LARBGSaAS CHI LAGU M 25 6n5 Hanning Pos 366 4MHz Figure 2 19 FFT Waveform Horizontal System Press Scope and then choose Horizontal to enter the horizontal function menu Delayed MernCepth Figure 2 20 Horizontal System Menu Delay scan zoom in the waveform being chosen Memory depth normal memory and long memory 16 SHS1000 Series SIGLENT Delay Scan Application Example Operation steps D pi oS YS Input a waveform to CH1 or CH2 Adjust time base to display the best waveform Press Scope and then choose Horizontal to enter horizontal system Press F1 to turn on delay scan Change time base and choose a window waveform to zoom in and analyze Press F1 to turn off delay scan izlent NAN G El E AA 61 13 23 57 24 CHi 1861 MM SAN CH1 FB Bimli WI Pos BAe ps Figure 2 21 Delay Scan Waveform Normal Memory and Long Memory under Real Time Sample Application Example Operations steps 1 a Input a sine signal with 100M bandwidth and 4V Vpp to CH1 or CH2 adjust time base to 50nS The common storage sampling rate will be 1GSa s while the long storage is 500MSa s at this time Press Run Stop respectively at common storage and long storage Change time base to let the whole waveform display on the screen Count memory depth Sampling Poi
46. nnnnnncnnnnnnnnnnnnconcccnnnnononononnnnnonnnnnnnoncrccncnnnnnonnnnnnnnnns 48 Making DC and AC Current Measurement iiiscccccccccccccciiciiiiiiiceeeiiiinns 49 Chapter 4 Using the Recorder Functions 0000000000000000000 0000000000000000 000000000000 nne 51 OscilloScope Trend PIO arar a cata 52 Waveform RECO ri os 55 Multimeter Trend Plot au o 58 Chapter 5 Prompting and Troubleshooting oooooococooooooooooococcccccccnonocononocononocononococcconos 61 System Prompting Messages Instruction oooooonccccncccnnnnnnonnnonononananonncccnnnncnnnnnnnononanonos 61 TAOUDIESNOONNGL inang TAG AGA A ag AN pa ag NG AANE ad 63 VI SHS1000 Series SIGLENT Chapter 6 Service and Support ccccccccococccooooosccccccocoeesoccccccu0occceueeesocooooeesesseococves 65 Mamntain S INGGI ATV as saa pagas a a an aan a E ES EA EE E ear Gn a CRC R T anaa ne a aa a 65 KONG GLEN Tanto a Ka aa an a kd aa a a na a da a aga aa tT E a Laa a aa aaa ahaaa 65 Appendix A Specifications 000000000000000000000 0000000000000000 iii eaaa aee 66 Appendix B Default Setup vns a ri 75 Appendix C Battery Installation 000000000000000000000000000000000000000000000 000000 00000000000000 eaaa eaaa 71 Appendix D Daily Maintaining and Cleaning 0000000000000000000000000000000000000000000 0000000000 00000 78 SHS1000 Series VII SIGLENT Chapter 1 Accidence About this C
47. nts Sampling Rate Sampling Time M E 4 a A4 41 14 4 01 12 i M Pos 6 48 ps O aga aane TE WG 1 8 000 MHz CHi Lae MM 16 ps CHi FB B6m HORTIOM Delayed MemDepth Figure 2 22 Normal Memory SHS1000 Series 17 SIGLENT HA G01 14 Rika M Pos 4 88 ps E i gt IEE T Hz MM n ms HOREON Delayed MemDepth Figure 2 23 Long Memory Reference waveform Press Scope and choose Ref to enter the reference waveform function menu Source Save Figure 2 24 Reference waveform Menu Table 2 11 REF Waveform Function Menu CH1 CH2 Choose the waveform to be saved the waveform to be saved ETA to save or recall the reference position of Ref A Ref B the waveform Baye Save the source waveform to the pointed reference position On Display the reference waveform on the screen Ref A Ref B PA Off Clean the reference waveform on the screen Reference Waveform Application Example Operation steps Input a waveform to CH1 or CH2 Adjust time base to display the best waveform Press Scope and choose Ref to enter horizontal system Choose the reference waveform need to save and press F4 to save Press F5 to show the reference waveform Press F5 to exit the reference waveform Yo 3 p D a 18 SHS1000 Series SIGLENT TT T T T T T T T SEREI ELER LELEL 20000 0000 0000 kHz i EEEE FEF Wray REF A Figure 2 25 Ref
48. or and USB flash disk storage mode N BOO NS 56 SHS1000 Series SIGLENT 8 Press F1 to start recording data The waveform will not move right and the recorded data saved to memory The recorded time will be different according to the time base You can pause or stop at any time CHi LAGI Save ade Figure 4 11Waveform Recorder Interface Waveform replay 9 Press F2 toreplay waveform You can replay the recorded waveform for several times and you can Advance or back off at any time 10 Press F5 to exit the waveform recorder SHS1000 Series 57 SIGLENT Multimeter Trend Plot l 2 3 4 lt Time ABA ZS 1178v ee 5 10 E TrendPlot taRate Mest Page _ Restart EEE Figure 4 12 Multimeter Trend Plot User Interface current recorded time the percentage of the current data take in the whole memory the parameter value of the recorded data up to the minute DC AC manual auto the real time the sample time of the cursor point the parameter measurement value of the cursor point vertical scale 0 vertical scale a oP A oS SYS TrendFlot SaRate Mest Page Figure 4 13 Multimeter Trend Plot Menu 1 Table 4 6 Multimeter Trend Plot Function Menu 1 Quilt the current data and start to record Restart afresh 10Sa 0 005Sa Set sampling rate Display Display the recorded data up to the minute mode Display all dots Recor
49. ore waveform falling The time between the first voltage level rising from 10 to Rise Time 90 The time between the first voltage level falling from 90 a Fall Time ao gt j i 0 h The duration of a burst over the entire waveform The time between the first rising edge and the next falling Wid edge of 50 voltage level wia The time between the first falling edge and the next rising Ki edge of 50 voltage level The ratio between the first positive pulse width and the i i period The ratio between the first negative pulse width and the ud period The phase difference between two waveforms The time between the first rising edge of source 1 and the first rising edge of source 2 AH The time between the first rising edge of source 1 and the FRR H Ll dll da first falling edge of source 2 FA The time between the first falling edge of source 1 and H L FFR Bp the first rising edge of source 2 The time between the first falling edge of source 1 and JA FFF the first falling edge of source 2 st LRR aig LRF ist LFR TE LFF PL PL PL FE _ The time between the first rising edge of source 1 and the H T i last rising edge of source 2 A H L A The time between the first rising edge of source 1 and the last falling edge of source 2 The time between the first falling edge of source 1 and FRRO the last rising edge of source 2 ma The time between the first fallin
50. ource on the trigger interface whether or not matches the signal channel Check the trigger mode normal signal should use the edge trigger mode The video signal should use the Video Trigger mode The signal would display steady only using the matching trigger mode Attempt to change the coupling into HF Reject or LF Reject display so that the High low frequency noise disturb the trigger should be filtrated Press RUN STOP button but no display Check the trigger mode on the trigger interface whether or not in the normal or single and check the trigger level is whether or not over the wave range If yes please put the trigger level to the middle position or set the trigger mode to the Auto position In another hand you could choose the Auto button to set up automatically SHS1000 Series 63 SIGLENT 6 After the Acquisition is set to Averages or Display Persistence time is set too long the waveform refreshes slowly It is normal in these settings 7 The signal is displayed as ladder like waveform 1 This phenomenon is normal The time base maybe is too slow you should turn the horizontal SCALE knob to increase horizontal resolution to improve the display 2 Maybe the display Type is set to Vectors You could set it to Dots mode to improve the display 8 The multimeter measurements aren t correct 1 Check that if the range of the SHS1000 matches with the m
51. pe and choose Math to enter the math waveform function menu Operation Inver Mest Page _ cc Figure 2 14 MATH Menu Table 2 8 Math Menu Function tracto Operation Invert FT on on Mest Page Figure 2 15 MATH Function Menu Table 2 9 Addition operation A Use arrow keys to move the waveform upright Can Use arrow keys to adjust the scale of math waveform Waveform Turn on the math waveform Math Switch Unique key turn off the math waveform Next page Page2 2 Return to the first menu off math waveform Waveform Math Application Example Operation steps of adding two waveforms 1 a gt D 11 Input two signals to the channels and press Auto Press Scopel and choose Math to enter waveform operation Press F1 to choose operation Press F5 to enter the second page of waveform operation menu Use Ii and 24 functions keys and the arrow keys to change the parameter to display the best waveform Press F4 to exit the math waveform operation SHS1000 Series SIGLENT v AL cale 2 691 CHi Z 9ALU CHZ ZBB 1111111 1111111111 M 258 ps G 1 0 CH1 Z 9 88ml MATH blext Page Figure 2 16 Result of Two Waveforms Add About FFT operation Using FFT math operation can translate time field signal to frequency field signal Operation FFT Scale Source Window FFT Zoom Hanning Mest Page K Figure 2 17 FFT Function Menu 1 Displ
52. r l CH2 trigger type Edge Pulse Video Slope X Y Mode X pole Input Y pole hae put PS Channel 1 CH1 Channel 2 CH2 Support 25KSa s 250Msa s sampling rate 1 2 5 5 Sampling Frequency order 68 SHS1000 Series SIGLENT Measure System Vpp Vmax Vmin Vamp Vtop Vbase Vavg Mean Crms Vrms ROVShoot FOVShoot Auto Measure 32 types RPREShoot FPREShoot Rise Fall Freq Prd Wid Wid Dut Dut BWid Phas FRR FRF FFR FFF LRR LRF LFR LFF Cursor Measure Manual mode Track mode and Auto mode Control Panel Function Auto Set Auto adjusts the vertical horizontal system and trigger position Support 2 groups of referenced Waveforms 20 Save Recall groups of setups 10 groups of captured Veen internal storage recall functions and USB flash driver storage function Hard Ware Frequency Counter Reading 1Hz resolution DC coupling 10Hz to maximal bandwidth Signal Types It s to all trigger signals Except pulse width and video trigger Digital Multimeter Specifications Environment Temperature 235 C Relative Humidity lt 75 Max Display 6000 DC voltage AC voltage resistance diode continuity Measure Function l capacitance DC current AC current AC virtual value 750V AC Frequency 20Hz 1kH Max Input Voltage l q y A DC 1000V AC virtual value 10A AC Frequency 20Hz 1kHz DC 10A DC Voltage 1 1945digi Max Input Current SHS1000 Series 69 SIGL
53. rigger Type Source When Set VYidth next Pace Pulse ENS Figure 2 40 Pulse Trigger Function Menu 1 Table 2 22 Pulse Trigger Function Menu 1 Select the pulse to trigger the Type Pulse pulse match the trigger condition DP ae Positive pulse width less than pulse width set 1 Positive pulse width larger than pulse width setting A Positive pulse width equal to pulse width setting Negative pulse width less than pulse width setting Negative pulse width larger than pulse width setting Negative pulse width equal to pulse width setting Selecting this option can turn the Set Width 20 0ns 10 0s arrow keys to set up the pulse width Next Ente r the second page of the Page 1 2 Page menu Type Mode Mest Page Pulse Auto Set Lit Figure 2 41 Pulse Trigger Function Menu 2 Compare the trigger conditions of pulse It triggers as soon as matching the conditions Condition Table 2 23 Pulse Trigger Function Menu 2 Select the pulse to trigger the pulse match the trigger condition Select the type of triggering Normal mode is best for most Pulse Width trigger applications Enter the Trigger setup menu Next Page Page 2 2 Return to the first page of the menu 28 SHS1000 Series SIGLENT Pulse Trigger Application Example Operations steps Input a pulse signal Trigger to enter trigger menu F1 to choose pulse trig
54. rightness gt Set grid brightness Enter the second page of DISPLAY Next Page Page 1 2 ni pag A a mpi Menu Meta Format Screen Grid DESI en Mest Pace TO Pave 22 Figure 2 12 Display Menu 2 12 SHS1000 Series SIGLENT Table 2 7 Display system function menu 2 Option Setting introduction y YT format displays the vertical voltage in relation to time horizontal scale Format XY format displays a dot each time a XY sample is acquired on channel 1 and channel 2 Normal Set to normal mode Screen Inverted Set to invert color display mode Display grids and axes on the screen Grid Turn off the grids Turn off the grids and axes Menu 2sec 5sec 10sec o Set display time of menu on the screen Display 20sec Infinite Next Page Page 2 2 Return to the first page of DISPLAY menu XY Waveform Application Example Observe XY waveform operation steps 1 Input 2 sine signals to the channels with the same frequency range and phase 90 degree difference press the button Auto Press Scopel and choose Display to enter the display system Press Next Page to enter the second page of DISPLAY menu Press F1 to choose XY mode Adjust the vertical range of CH 1 and CH 2 to obtain the best XY waveform a SY Siglent NENE 19 E 11 47 15 17 39 42 CHi LBB CH2 LEBI Sa L256MHz sY mode Figure 2 13 XY Waveform SHS1000 Series 13 SIGLENT Math Waveform Press Sco
55. rms averages them and displays the final waveform The more average times the smoother of the waveform Equivalent Time Sampling This mode is good for observing repetitive period waveforms The sampling rate is up to 50GSa s Real Time Sampling The scope has the highest real time sampling rate up to 1GSa s Interpolation Sinx x Application Example Operation steps 1 Press Scope and choose Acquire to enter acquiring system 2 Press F4 to choose Ream Time 3 Press F3 to choose Sinx x Siglent MME eden E A M Pog 8 08 ps Paces o E 1 AA ADI MHz i EFEC M 2 50ns CHi FAAAM AOQUIRE Acquisition Simak Made Sa Rate Sampling RealTime Pies Figure 2 9 Sinx Interpolation SHS1000 Series 11 SIGLENT M Pio 2 88 ps 1 00 001 MHz a re ca CHIL iam M256ns CHiFAB6m AQQUIRE Acquisition Sieu Mode SaRate Sampling RealTime Pie Figure 2 10 X Interpolation Display System Press Scopel and choose Display to enter display system See Figure 2 6 Type Persist Intensity Brightness pje Pace Figure 2 11 Display Menu 1 Table 2 6 Display System Function Menu Vectors fill the space between adjacent Vectors ae Type sample points in the display Dots Dots display sample points directly Off 1 sec Sets the length of time each displayed ika eee sample point remains displayed 5 sec ple p played Infinite Intensity 4D lt intensity gt Set waveform intensity Brightness V lt B
56. steps 1 Input a signal to CH1 or CH2 and then press Auto 2 The SHS1000 adjusts its settings automatically to display the best peak peak average period frequency and other information according to the characteristics of the signals 3 Adjust time base and voltage range manually to obtain waveforms needed if necessary Siglent MIN GREAT E E 11 07 15 17 15 47 CHI j Upp 572 an 6 527m T Prd 1 fikim s Freq 1 GG6KHz G 1 B6666kHz CHi Lael M 588 ps CHi BBm M Pos 6 80 ps Figure 2 1 Automatic Setting CH1 CH2 Channel Functions Press CH1 CH2 to enter CH1 CH2 channel menu Coupling w Limit vots Di Probe Mest Page Figure 2 2 Channel Menu 1 SHS1000 Series 7 SIGLENT Table 2 2 CH1 CH2 function Menu 1 Option Setting Instruction components of the input signals l AC blocks the DC component of the coupio AC input signals and attenuates signals below 10 HZ GND disconnects the input signal Limit the bandwidth above 20M to a On reduce display noise filter the signals to BW Limit Off reduce noise and other unwanted high frequency components Change the range of voltage by 1 2 5 j iii seguence V div Fine Fine changes the resolution by small steps under the coarse settings Probe 1X 5X 10X 50X Set to match the type of probe you are 100X 500X 1000X using to ensure correct vertical readouts Enter the second page of CH1 CH2 vert Mest Pace
57. t operation lhkSaver Layout PaperSie Printkey Next Pace Default Figure 2 63 Print Setting Menu 1 Table 2 40 Print Setup Function Menu 1 On Print the screen image on a white Ink Saver Off background when you select On Layout Portrait Landscape The output direction of the printer l Set the type of the Displays settings available on your Paper Size j paper PictBridge compatible printer 40 SHS1000 Series SIGLENT Choose Print Picture option and press Save Recall for 4 seconds to print the picture while the SHS1000 connects to the printer Print Ke y Choose Save Picture option and press l Save Recall for 4 seconds to save the Save Picture l l l picture while you insert an USB flash driver to the SHS1000 Print Picture Next Page Page 1 2 Enter the second page of the menu magskze PaperType PrintQualty IDPrint Next Page Figure 2 64 Print Setting Menu 2 Table 2 41 Print Setting Function Menu 2 setting introduction Image Size Set the type of the paper PictBridge compatible printer partie phan Photo FastPhoto Print Quality Default Normal Draft Fine o ID Print Default On Off Return to the first page of the Next Page Page 2 2 menu Waveform Record Waveform record record waveform with a designated interval until reaching the end frame When recording CH1 or CH2 waveform users can set the interval between frames The recorder can record 2500 frames
58. te Display Mode l l Display all date in a compressing proportion Record data automatically Manual On Record data manually A Record presses a record Waveforms Memory data transfer to exterior storage device Return to the oscilloscope interface Next Page Page 2 2 Return to the first page of the menu First choose a measurement in scope or meter mode You can choose the recorder functions from the waveform recorder main menu To open the main menu do the following Press Recorder to open the recorder main menu Scope Scope Meter Trend Plot Recorder Trend Plot Figure 4 4 Recorder Function Main Menu Scope Trend Plot Application Example Operation steps Open trend plot function 1 Input a signal to CH1 or CH2 Press Recorder to enter the recorder main menu Press F1 to choose Scope Plot Choose measured parameter A B and start recording the trend plot The scope Press F5 to pause or continue recording data oe OS TO SHS1000 Series 53 SIGLENT 257MHz2 U azh AmA EAR aL Se S 064MHz76 AH 01 236 TrendFlot Parana Pararn 8 Met Page CHI Vpop CH1 Freq Page 12 Figure 4 5 Trend Plot record Curve Display recorded data 6 Press F5 to enter the second page of trend plot menu 7 Press F1 to choose data display mode Normal the screen displays the data up to the minute View All the screen displays all data in the memory 8 Zoom function under full screen mode press
59. the All Measurement menu Return to the home page of MEASURE menu Voltage parameter measure Source ice T L pp 1 28 8ml J Figure 2 31 Parameter Measure Function Menu SHS1000 Series 21 SIGLENT Table 2 15 Voltage Measure Function Select input signal source for voltage measure Vpp Vmax Vmin Vamp Vtop Press F2 or use the arrow keys to Type Vbase Vavg Mean Vrms FOV select voltage measure Source CH1 CH2 parameter Display the corresponding icon and measure value of your selected Voltage measure parameter Return to the home page of MEASUREMENT menu Time parameter measure Source Type Period i gams Figure 2 32 Time Measure Function Menu Table 2 16 Time Measure Function Select input signal source for Time Source CH1 CH2 a measure Period Freq Wid Wid Rise l Press F2 or use the arrow keys to Type Time Fall Time BWid Dut select time measure parameter Display the corresponding icon and measure value of your selected time measure parameter O AS MEASURE menu Delay parameter measure Source Type Phase ee Figure 2 33 Delay Measure Function Menu 22 SHS1000 Series SIGLENT Table 2 17 Delay Measure Function Select input signal source for delay Source CH1 CH2 measure Press the Type button or use arow keys to select delay Phase FRR FRF FFR FFF LRR LRF LFR LFF measure parameter Display the correspon
60. the equipment Before use inspect the test leads for mechanical damage and replace damaged test leads Whenever it is likely that the safety has been impaired the SHS1000 must be turned off and disconnected from the line power The matter should then be referred to qualified personnel SHS1000 Series Il SIGLENT Introduction of SHS1000 Series Handheld Digital Oscilloscope This manual mainly introduces SHS1000 series Handheld Digital Oscilloscope Adopting bandwidth isolation technique SHS1000 realizes that all input ports are isolated so that high voltage signals can be measured safely This series combines functions of scope multimeter and recorder It provides real time sampling rate as high as 1GSa s maximal bandwidth 100MHz 2Mpts memory depth small volume compact interface and etc It satisfies the most needs of outside measurement and improves working efficiency greatly Function Characteristics The SHS1000 combines the functions of oscilloscope multimeter and recorder including trend plot and waveform recorder along with isolated double channels Adopt bandwidth isolation technique SHS1000 realizes that both scope and multimeter input channels isolation CATII1000V and CATIIIGOOV between two channels references between channels reference and earth ground CATII600V and CATIII300V between channels reference and Multimeter input reference CATII300V and CATIII150V input direct CATII1000V and CATIIIG0
61. the relative according to the real demand Choose Manual or Auto according to the real demand Read voltage value Making Resistance Measurement a a A O O O 99 6Q 100 200 300 400 500 600L MAMLAL Meter Relative Res Crt Mangal Trend Flot Figure 3 4 Resistance Measurement Operation steps 1 Press Meter to enter multimeter mode press F1 to choose Res measurement 2 Insert the red probe to the V Q C banana jack input and the black probe to the COM Connect the other end of probes to the power or load to be measured 3 Turn on off the relative according to the real demand 4 Choose Manual or Auto according to the real demand 5 Read resistance value Notes When measuring resistant please make sure that the circuit is power off and the Capacitance is discharged to avoid damage to the SHS1000 46 SHS1000 Series SIGLENT Making Diode Measurement L O O O 0 554V Jl 0 4 0 8 1 2 1 6 AU Meter Diode Figure 3 5 Diode Measurement Operation steps 1 Press Meter to enter multimeter mode press F1 to choose Diode measurement 2 Insert the red probe to the V Q C banana jack input and the black probe to the COM Connect the other end of probes to the diode to be measured 3 Read the value Making Continuity Measurement I 3 O O O 0 000 ol 100 200 300 400 500 00t Meter Continuity Figure 3 6 Continuity Measurement SHS1000 Series 4
62. the trigger level SHS1000 Series 3 SIGLENT Function Check Let s make a quick function check to make sure whether the SHS1000 works normally Please do the following steps 1 Power the SHS1000 The SHS1000 performs all the self check items and makes sure that it passes the self check 2 Connect the probe to the CH1 of the SHS1000 Align the slot of the probe connector with the salient on the CH1 BNC push down and twist right to lock the probe Connect the probe tip and reference lead to the Probe Comp connectors 3 Press Auto you will see a square wave with 1 KHz frequency and about 3V peak peak in a few seconds 4 Press CH1 twice to cancel channel 1 then press CH2 to display channel 2 and repeat step 2 and 3 Probe Probe Safety There is high voltage protected material around the probe and no metal exposed to the air Don t use probe with broken insulation Probe Compensation When you connect the probe to an arbitrary channel for the first time please make the following adjustment to make the probe match with the channels Probe without compensation or compensation warp may lead to imprecise or false measurements You can perform the adjustments manually to match your probe with the input channels 1 Set the probe option attenuation in the channel menu to 10X and connect the probe to channel 1 on the scope If you use the probe hook tip make sure that the hook tip is fixed on the probe firmly 2 Attac
63. time base to zoom in or zoom out 9 Data analysis move cursor analyzing data over time ee 2380V Mtz 910 00r1Y A EE 2300U 0 00 09 010 6024MHz B 00 17 008 TrendPiot Params Param Next Page CH1 pp CH1 Freq Page 12 Figure 4 6 Analyzing Trend Plot 10 Save waveform save the recorded waveform to exterior storage device to make more detailed analysis 11 Press Return to exit trend plot 54 SHS1000 Series SIGLENT Waveform Recorder Press Recorder to enter recorder main menu under scan time base then press F2 to choose Scope recorder Figure 4 7 Waveform Recorder Menu Table 4 3 Waveform Recorder Function Menu Record waveform without gap Replay Replay the recorded waveform Setup the parameters of waveform recorder return Exit waveform recorder function Save hlode Figure 4 8 Waveform Recorder Saving Mode Menu Table 4 4 Waveform Recorder Saving Mode Function Menu Start Begin to record waveform record waveform under 100mS and above scan time base Replay the recorded waveform Copy the waveform saved in the memory to the USB flash disk Choose a place to save record including memory USB flash Save mode disk USB flash driver saves only under 2 5s div and above time base Exit the submenu and return to the waveform recorder main return menu Figure 4 9 Waveform Recorder Replaying Mode Menu SHS1000 Series 55 SIGLENT Table 4 5 Waveform Recorder Replaying Mode Fu