1. DLO5 CPU Specifications System capacity Total memory available words Ladder memory Words 0 cccceeee ew ees 2 048 V memory words 4 096 User V M MONY cccceceeseeeeeeneenenenees 3 968 Non volatile user V memory Battery backup Total built in 1 0 Performance Contact execution Boolean Typical scan 1K Boolean Instructions and diagnostics RLL ladder style RLLPLUS flowchart style Stages Number of Instructions Types of Instructions Control relays Immediate 1 0 Subroutines For next loops Timed interrupt Integer math Drum sequencers Bit of word ASCII print Real time clock calendar Internal diagnostics Password security System and user error log Communications Built in ports Protocols supported K sequence proprietary protocol DirectNet master slave Modbus RTU master slave ASCII out Baud rate PON e aE essa nies 9 600 baud fixed selectable 300 38 400 baud default 9 600 Specialty Features Filtered inputs Interrupt input High speed counter Pulse output Pulse catch input 1 These features are available with use of certain option modules Option module specifi cations are located later in this section 2 Our 1K program includes contacts coils and scan overhead If you compare our products to others make sure you include their scan overhead 3 Input features only available on units with DC inputs and output features only available on units with DC outputs
2. Prices as of April 16 2014 Check Web site for most current prices DLO6 CPU Specifications System capacity Total memory available words Ladder memory words V memory words User V memory Non volatile user V memory Built in battery backup D2 BAT 1 Performance Contact execution Boolean Typical scan 1K Boolean 2 Instructions and diagnostics RLL ladder style RLLPLUS flowchart style Stages Run time editing Number of Instructions Types of Instructions Control relays Immediate 0 Subroutines For next loops Table functions Timed interrupt Integer math Trigonometric functions Floating point math Drum sequencers Bit of word Number type conversion ASCII in out print LCD instruction Real time clock calendar Internal diagnostics Password security System and user error log Communications One RS 232C One multi function RS232C RS422 RS485 NOTE RS485 is for MODBUS RTU only Protocols supported K sequence proprietary protocol DirectNet master slave Modbus RTU master slave ASCII in out Baud rate POM Ihessvictecagunbarcsateseene ase 9 600 baud fixed selectable 300 38 400 baud default 9 600 Specialty Features Filtered inputs Interrupt input High speed counter Pulse output Pulse catch input 1 These features are available with use of certain option module Option module specifica tions are located later in this section 2 Our 1K program includes contacts coils and scan overhead If you
3. RXD Receive data RS 422 485 to make option module wiring easier OV Power connection GND TXD Transmit data RS 422 485 10 TXD Transmit data RS 422 485 DLO6 12 RTS Ready to send RS 422 485 Hl RXD Receive data ee CTS Clear to send RS 422 485 PORTI PORT2 CTS Clear to send RS 422 485 Modular Connector D sub Connector i 6 pin Female Modular Connector vs y17 Y14 Hz 40VA D0 06DR O 21 22 23 1000 m TERM X21 a x22 an J e e BQ 00000 ele I PORT1 PORT2 RUN STOP toring device N CPU is forced into the STOP mode No cals are allowed by the program ming monitoring device So a ozn 2 239 A 4 X lt N o000000 3 NISIA DO O6ADPTR O 20 Q a a Q Q O O O a amp RS 422 485 A wk i Q amp I 6 pin Female 15 pin Female Book 1 14 1 www automationdirect com DL05 DL06 PLCs eDS 27
4. compare our products to others make sure you include their scan overhead 3 Input features only available on units with DC inputs and output features only available on units with DC outputs 1 800 633 0405 Prices as of April 16 2014 Check Web site for most current prices Amomation Features at a Glance DirectSOFT software i aA e ices pees Mounting tab Input status indicators Mode switch Communication ports Output status indicators ware that our larger PLCs use A FREE y version of DirecfSOFT gives you all the ke u great features of the full version but with a 100 word PLC program download a Py a larger OKO XA X2 x8 X4 XS XB X7 aner words the full package is required The FREE PC DS100 software may be suffi GOV GOV epee DirectLOGIC cient to program the DLOS and DLO6 It Direct 5 l you are programming with a full package LC Y Porru version prior to v5 0 you will need v2 4 or yi het later for the DLO5 PLCs and v4 0 or later ee oe Oe for the DLO6 We always recommend the EE oe Ee l latest version for the most robust features a ee ee e ea Removable See the Software section in this catalog Olea aoa aaa Te lt for a complete description of DirectSOFT ra ZATEN CN ES GEN CS ES CSG F ro including features part numbers of Noe programming packages and upgrades External power inputs Discrete input terminals Discrete output terminals Option module slot Hardware features
5. DIN Rail smm 0 43 mounting tab 11mm Book 1 14 1 eDS 23 Automation Direct DirectLOGIC DLO5 06 Prices as of April 16 2014 Check Web site for most current prices Auntormatiatl Ports Status Indicators and Modes Port 1 Port 2 DLO5 and DLO6 status Port 1 is a 6 pin fixed configuration port Pott 2 is a configurable port on both the indicators and has the same pin assignments on the DLO5 and the DLO6 PLCs The DLO5 PLC DLO5 and the DLO6 Please refer to the table uses a 6 pin modular connector and offers Status Indicators and diagrams on this page This port can be RS 232 communications only The DLO6 Indicator Status Meaning used to connect to an HPP DirecfSOFT an PLC uses a 15 pin HD sub connector operator interface or other external device and offers RS 232 RS 422 or RS 485 PWR a Features include communications Please refer to the table OFF Power failure e 9600 baud and diagrams on this page for more infor a ON CPU is in Run Mode o Oaai mation This port can be used to connect OFF CPU is in Stop or Program Mode DirectLOGIC e Odd parity to an HPP DirectSOFT an operator inter DL05 06 f h f ON CPU self diagnostics error 1 start bit 1 stop bit ace or other external device Features o CPU a aT 2400 4800 9600 default eee o 9 e a u f Asynchronous half duplex DTE 19 200 38 400 baud ee trans
6. Prices as of April 16 2014 Check Web site for most current prices Product Dimensions and Installation 0 39 10mm F 3 4 properly to ensure ample airflow for atols osode O E clearance for 6 screw cooling purposes It is important to follow the unit orientation requirements and WOT tec wea to verity that the PLC s dimensions are DDOD Ceeerere compatible with your application Notice Direct h particularly the grounding requirements Da and the recommended cabinet clear ances 120mm Pil ox a X1 X2 X3 X4 X5 X6 X7 yo Yi Y2 Su DDOD OO Direct 05 a bee X0 X7 Input vo vs oun EG cd ON CSP Airflow J P aT erry Mounting orientation 9 09 0 39 231mm 10mm 8 31 211mm k 5 00 127mm 4 61 117mm TERM PODON www automationdirect c PORT1 PORT2 RUN STOP om Fiteeae 0 20 5mm A S ape DL05 DLO6 PLCs Mounting orientation 2 56 65mm 0 24 mounting tab a 6mm 2 68 68mm DIN Rail 2 68 _ gt 68mm
7. diagrams External power inputs Discrete output terminals Removable Option module slots Nam NE ce EEEREEEREL IIIS s licz ov vo v2 ct ys v7_ Output status indicators S Mode status OUTPUT 6 240V 50 60Hz 2 0A 6 27V 2 0A PWR 100 240V 50 60Hzy40VA indicators OPTRETT DO OGDR 12 13 14 15 16 17 20 21 22 23 gt OOO DOOOOOOOOOOO O _ KBU T AA a tome Input status indicators Communicat ion status indicators Direct f LOGIC Koyo SS e o TERM Mode switch EISISIEIEISISIEIEIETS deele e PORT1 PORT2 RUN STOP JEISIPIRISISIESIEIISIE A a TOJ Discrete input terminals Removable Communication ports Mounting tab terminal block Book 1 14 1 www automationdirect com DL05 DL06 PLCs eDS 21 Prices as of April 16 2014 Check Web site for most current prices Product Dimensions and Installation It is important to understand the installa tion requirements for your DLO5 or DLO6 system Your knowledge of these require ments will helo ensure that your system operates within its environmental and electrical limits Note There is a minimum clearance requirement of 2 51mm between the panel door or any devices mounted in the panel door and the nearest DLO5 component Plan for safety This catalog should never be used as a replacement for the user manual You can purchase download free or view online the user manuals for thes
8. e Features at a Glance The DLO5 and DLO6 micro PLCs are complete self contained systems The CPU power supply and O are all included inside the same housing Option modules are available to expand the capability of each PLC family for more demanding applications The standard features of these PLCs are extraordinary and compare favor ably with larger and more expensive PLCs The specitication tables to the right are meant for quick reference only Detailed specifications and wiring information for each model of the DLO5 and DLO6 PLCs can be found in those specific sections Program capacity Most boolean ladder instructions require a single word of program memory Other instructions such as timers counters etc require two or more words Data is stored in V memory in 16 bit registers Performance The pertormance characteristics shown in the tables represent the amount of time required to read the inputs solve the Relay Ladder Logic program and update the outputs Instructions A complete list of instructions is available at the end otf this section Communications The DLO5 and DLO6 offer powerful communication features normally found only on more expensive PLCs Special features The DC input and DC output PLCs offer high speed counting or pulse output Option module slots allow for discrete I O expansion analog I O or additional communication options Book 1 14 1 DS 20 DL05 DLO6 PLCs
9. e products The DO USER M is the publication for the DLOS PLCs and the DO O6USER M is g o 50mm the publication for the DLO6 PLCs The wie T DO OPTIONS M is the user manual for the option modules These user manuals contain important safety information that must be followed The system installation eee ds y s INPUT 7 Power source Dee AIIN Pe Ao d f gu should comply with all appropriate elec z eomma trical codes and standards min JS ground terminal aD Panel Ground braid cop no V Panel or single int groun Star washers Star washers point grouna See the Enclosure section to find an enclosure that fits your application Temperature probe Environmental Specifications for DLO5 and DLOG 4 F 158 F 20 C to 70 C Ambient Operating 32 F 1319F Temperature 0 to 55 C 5 to 95 relative Ambient Humidity humidity non condensing MIL STD 810C Method 514 2 MIL STD 810C Note There is a minimum clearance requirement of 1 5 38mm Method 516 2 between the panel door or any devices mounted in the Noise Immunity NEMA ICS3 304 panel door and the nearest DLO6 component Storage Temperature Vibration Resistance Shock Resistance Atmosphere No corrosive gases Book 1 14 1 eDS 22 DLo5 DLO06 PLCs 1 800 633 0405 Unit dimensions and mounting orientation DLO5 and DLO6 PLCs must be mounted
10. mitted by the Protocols supported as slave e 8 data bits No data is being transmitted by K sequence DirectNET Modbus RTU Odd default even or no parity the CPU Port 1 z a i i Data is being received by the DLO5 amp DLOG Port 1 Pin Descriptions Leao opt CPU Port 1 Station address ae Power connection GND Md tis a received by the Por Power connection 1 default a Data is being transmitted by the Receive data RS 232C 1 90 DirectNET K sequence CPU Port 2 Transmit data RS 232C No data is being transmitted by 1 247 Modbus RTU the CPU Port 2 Power connection e Asynchronous half duplex DTE Data is being received by the CPU Port 2 No data is being received by the CPU Port 2 Power connection GND Protocols supported e K sequence slave Direct NET master slave Modbus master slave DLOS Port 2 Pin Descriptions DLOS and DLO6 mode Power connection GND switches Power connection Mode Receive data RS 232C Switch CPU Action Transmit data RS 232C Position Ready to send CPU is forced into the RUN mode if no errors are encountered No program hs are allowed by the program ming monitoring device RUN PROGRAM and the TEST modes are available Mode and program changes are allowed by the programming moni Power connection GND PORT1 PORT2 DLO6 Port 2 Pin Descriptions Use the optional low profile 15 pin adapter