Home

Instruction Manual - VASCA Aquarium Supply

image

Contents

1. 2003 Rolf C Hagen USA Corp All Rights Reserved HAGEN CYCLEGUARD NUTRAFIN AQUAPLUS and CYCLE are registered trademarks of Rolf C Hagen USA Corp Mansfield MA
2. can be used to remove more stubborn deposits Wet motor seal ring to prevent damage before placing into filter case AquaClear Power Filter Quick Start Guide PACKI NG LIST Congratulations on the purchase of your new AquaClear Power Filter Please allow approximately 15 20 minutes for the complete installation of filter parts and inserts The rewards to your aquatic adventures will be worth it Inspect AquaClear power filter for any visible signs of shipping damage and verify that motor is securely fas tened to filter case The following parts should be includ ed in your package ilter Cover Extension Tube All AquaClear Power Filters except Model 20 are shipped with two extension tubes PREPARING FILTER INSERTS ALL FILTER INSERTS MUST BE RINSED THOROUGHLY PRIOR TO INSTALLATION AquaClear Foam Rinse foam insert and place into filter basket first The foam block should totally fill the bottom of the basket leaving no space between the filter basket base and sides Replace foam insert every two months AquaClear Carbon Remove carbon insert from dust sleeve and rinse pouch to remove any carbon dust particles Flatten carbon insert and place horizontally on top of foam insert Replace carbon insert every month AquaClear BioMax Open poly bag and trans fer contents into mesh bag Apply locking clip as
3. from an outlet when not in use 6 Do not use this pump for other than intended use i e do not use in swimming pools bathrooms etc The use of attachments not recommended or sold by the appliance manufacturer may cause an unsafe condition Do not use this pump in swimming pools or other situations where people are immersed This pump is suitable for use in water temperatures up to 35 C Do not use this pump with inflammable or drinkable liquids 7 This pump is suitable for INDOOR use only Do not install or store the appliance where it will be exposed to the weather or to temperatures below freezing 8 Make sure an appliance mounted on a tank is securely installed before operating it 9 Read and observe all the important notices on the appliance 10 If an extension cord is necessary a cord with a proper rating should be used A cord rated for less amperes or watts than the appliance rating may overheat Care should be taken to arrange the cord so that it will not be tripped over or pulled The connection should be carried out by a qualified electrical installer 11 The pump must not run dry SAVE THESE NSTRUCTIONS For the complete use and understanding of this power filter it is rec ommended that this manual is thoroughly read and understood Failure to do so may result in damage to this filter HOW IT WORKS The AquaClear Power Filter draws water from the aquarium through an extension tube into the mo
4. to required setting NOTE If necessary an additional adjust ment may be made to level power filter by breaking off the leveler bar at base of motor POWER FILTER START UP a Fill power filter case completely with water and replace cover b Adjust water flow control lever on intake U tube to its maximum position for initial start up c Plug power cord into electrical outlet Allow 30 45 seconds for priming air to be expelled from U tube d After priming has been completed move adjustment control on intake U tube to adjust water flow rate as required See How it Works Patented Refiltration System IMPORTANT DO NOT OPERATE FILTER WITHOUT WATER NOTE For maximum filter operation and efficiency regular cleaning of the filter and its parts is recom mended every two weeks Soap or detergents are NOT recommended for filter maintenance See Power Filter Maintenance TROUBLE SHOOTING amp FAQs ALSO AVAILABLE FROM AQUACLEAR Q What if the power filter motor doesn t start or makes a mechanical noise Occasionally it might be necessary to use alternate filter inserts to maintain a well balanced healthy aquatic environment We offer t
5. 50 70 110 Maximum Flo Rate 100 gph 150 gph 200 gph 300 gph 500 gph 378 Iph 568 Iph 757 Iph 1135 Iph 1890 Iph Minimum Flo Rate 33 gph 50 gph 66 6 gph 100 gph 166 6 gph 125 Iph 190 Iph 250 Iph 380 Iph 630 Iph Watts 6 Watts 6 Watts 6 Watts 6 Watts 14 Watts RPM 3600 rom 3600 rpm 3600 rom 3600 rom 3600 rpm POWER FILTER MAINTENANCE Always unplug power filter prior to cleaning Remove cover filter basket and discard water remaining in the filter case Thoroughly rinse collected debris from the case impeller cover and impeller assembly in clear lukewarm water The intake U tube and extension tube can be cleaned with a filter stem brush to remove any buildup of deposits When all parts have been cleaned and thoroughly rinsed reassemble filter and replace onto aquarium See Quick Start Guide 2 3 and 4 Follow operating instructions to restart and prime power filter See Power Filter Start up Every three months the motor should be thor oughly cleaned Remove cover filter basket and discard water remaining in filter case Remove motor by twisting a 1 4 turn gently in the direc tion of the arrow on front Ease motor down slowly to prevent damage to the filter and motor guide Pull impeller out of impeller well and rinse to remove accumulated slime deposits A cotton swab or impeller well brush not supplied
6. ace area for adsorption of undesirable impurities The activated carbon filter insert will remove unwanted odors discoloration and impurities resulting in a crystal clear aquarium Stage 3 Biological BioMax Insert AquaClear BioMax Filter Insert contains BioMax ceramic rings STAGE 1 The surface of BioMax is made up of a complex pore system that allows bacteria to thrive Each ceramic ring contains approximately 100 square feet of surface area providing more biological power than a traditional cartridge Use of the BioMax Insert will provide optimal living space for benefi cial bacteria and enhance the removal of ammonia and nitrites resulting in a healthy aquarium environment NOTE Regular replacement of AquaClear filter inserts is essential for optimum filter performance PATENTED REFILTRATION SYSTEM For a healthy aquarium and clear water Sometimes delicate fish and plants require a gentler water flow AquaClear s patented refiltra tion system allows you to control the flow rate without compromising filtration efficiency When the flow rate is reduced up to 50 of the water within the filter chamber is processed multiple times More impurities are filtered out creating a healthier tank with sparkling clean and clear water NOTE A reduced flow rate is also recommended for use during feeding to ensure more efficient food consumption and less waste AQUACLEAR POWER FILTERS FLOW RATES MODEL 20 30
7. ems can be handled promptly with a toll free phone call Or if you prefer you can contact us on our web site at www hagen com When you call or write please have all relevant information such as model number and or part numbers available as well as the nature of the problem CALL US ON OUR TOLL FREE NUMBER 1 800 724 2436 between 8 30 am and 4 00 p m Eastern Standard Time Ask for Customer Service FOR AUTHORIZED GUARANTEE CONSUMER SERVICE Return unit with dated receipt plus 5 00 for shipping and handling to Rolf C Hagen U S A Corp Consumer Repair 50 Hampden Road Mansfield MA 02048 LIFETIME GUARANTEE AquaClear Power Filters are guaranteed against defects in material or work manship under normal aquarium usage and service for as long as you own the filter We offer a Lifetime Guarantee on all non replaceable parts which means that the filter will be repaired or replaced at the manufacturer s discre tion free of charge when the complete pump is returned with proof of pur chase and postage paid Please include 5 00 to cover shipping and han dling This warranty does not apply to any filter that has been subjected to misuse negligence or tampering No liability is assumed with respect to loss or damage to livestock or personal property irrespective of the cause thereof REGISTER ON LINE www hagen com To learn more about Hagen products For a copy of our FREE full color 40 page Basic Aquarium Guide
8. he following alternative chemical stage inserts as supe A Check to make sure impeller blades are free moving on magnet rior solutions to your filtration system assembly AquaClear Ammonia Remover Insert Q Why won t the power filter motor re start after performing Removes and controls harmful ammonia filter insert maintenance Ideal for new or heavily populated aquariums Reduces stress on fish A Make sure unit has been plugged back into power outlet and that Fa ewar asa oriy all parts are thoroughly clean and replaced as directed AquaClear Ammonia Remover Insert contains a natural ammonia removing See Power Filter Maintenance resin This resin chemically bonds with ammonia to remove it from the aquarium water Use of the ammonia remover insert will reduce and control toxic ammonia resulting in a healthy aquarium environment Q What should I do if the priming process doesn t occur A Verifiy that e all parts are installed correctly e filter case is completely filled with water e unit Is plugged Into power outlet Removes toxic ammonia odors discoloration and impurities e ensure U tube lever is set to maximum position For use to prevent buildup of toxic ammonia AquaClear Zeo Carb Filter Insert Combines activated carbon and ammonia remover in one Q Why is the water cloudy in my new aquarium Reduces stress on fish For freshwater use only A Bacterial cloudiness may occur during the first week
9. nk health and reduces fish loss when R z z d t of kl int Q Why should I use only aquarium water to rinse my filter gee hae eq ear cen inserts after they are installed A Most cities add chlorine or other chemicals to eliminate harmful bacteria in drinking water for human consumption These addi tives while harmless to us are very toxic to fish REPLACEMENT PARTS To re order parts for your AquaClear Power Filter please refer to Parts List below NEW MODEL 20 s hUcOC SOSCOC SCSCNC Formerly model Mini 150 200 300 500 Article A595 A600 A610 A615 A620 A Filter Case A16020 A16120 A16220 A16320 A16420 B Filter Basket A16040 A16140 A16240 A16340 A16440 C Filter Cover A16030 A16130 A16230 A16330 A16430 D Intake U Tube A16050 A16150 A16150 A16350 A16350 E Extension Tube A625 A625 A625 A627 A627 F Impeller Cover A16015 A16015 A16015 A16315 A16415 G Impeller Assembly A630 A632 A634 A636 A638 H Seal Ring A16017 A16017 A16017 A16017 A16417 l Motor Unit A16000 A16000 A16000 A16000 A16400 J Leveling Device A16325 A16325 A16325 A16325 A16325 Intake U Tube Adaptor N A N A N A N A A16412 Not shown Available for Model 110 only HOW TO CONTACT US If you have a problem or have questions about the operation of this product please let us try to help you before returning product to your dealer Most probl
10. of a new AquaClear Zeo Carb Filter Insert contains a mixture of ammonia removing aquarium set up and may last up to six weeks If the condition resin and premium research grade carbon This dual purpose insert gives the combined benefits of carbon and ammonia remover while allowing rsi nsul r local rium p I pola sts consult JOU OGA AAU professional you additional space in your filter for other types of inserts Q What happens if I forget to clean my filter inserts A If the power filter is left unattended for too long the filter inserts become clogged with debris In extreme cases the filter basket may be forced up from the filter case due to the pump pressure This is an indication that the efficiency of the filtration is very low and that the filter inserts require immediate rinsing or replace i AquaPlus Patented stress relief water conditioner Makes tap water safe ment See Filter Inserts Maintenance Protects fish and helps heal damaged fins cuts and wounds Ideal for new tank set up and water changes NUTRAFIN WATER CARE PRODUCTS For Improved Aquarium Health Q When should I operate a reduced flow A Reduced flow is most helpful during feeding times or when the ae zori aa ER ie alee J ntroduces beneficial bacteria to accelerate input suction or output stream is too strong for small or delicate nm h Temauaiaio mentnks Promoes fish See How it Works Patented Refiltration System ta
11. power cord of this appliance cannot be replaced if the cord is damaged the appliance should be discarded Never cut the cord V To avoid the possibility of the AquaClear Power Filter s plug or receptacle getting wet position the unit to one side of a wall mounted receptacle to pre vent water from dripping onto the receptacle or plug A drip loop A should be arranged to the recepta cle The drip loop is the part of the cord below the level of the receptacle or the connector if an exten sion cord is used to prevent water traveling along the cord and coming into contact with the receptacle If the plug or receptacle does get wet DO NOT unplug the cord Disconnect the fuse or circuit break er that supplies power to the appliance Then unplug and examine for presence of water in the receptacle A 3 Close supervision is necessary when any appliance is used by or near children 4 To avoid injury do not contact moving parts or hot parts such as heaters reflectors lamp bulbs etc 5 CAUTION Always unplug or disconnect all appliances in the aquarium from electricity supply before placing hands in water before putting on or taking off parts and whilst the equipment is being installed maintained or handled When inserting or removing the pump from the water always pull out the main electricity plug Never yank cord to pull plug from outlet Grasp the plug and pull to disconnect Always unplug an appliance
12. shown trim excess mesh and thoroughly rinse insert materials before placing on third level of the basket Replace BioMax insert every three months NOTE Regular replacement of AquaClear filter inserts is essential for optimum filter performance FILTER INSERTS MAINTENANCE The AquaClear Foam Carbon and Bio max inserts should be changed alternately in order to maintain continuous biological activity Follow individual packaging instructions for recommended replacement intervals Never replace all Filter Inserts in any AguaClear Power Filter at the same time 3 INSTALLING 4 ATTACHI NG FILTER I NSERTS INTAKE U TUBE After preparing filter inserts as indicated place filter a Install intake U tube as shown and apply gentle basket into filter case Gentle pressure may be neces pressure to click into position sary to ease filter basket into position due to b Additional slight pressure is then applied to ensure the snug fitting foam insert base of tube clicks into the opening over impeller cover c Attach extension tube on aquarium side of intake d Add more than one extension tube if tank depth requires it ATTACHING LEVELING DEVICE Power filter must be level to ensure optimal performance Insert leveling device into bottom of filter case Mount power filter onto rear of aquarium and adjust leveling device by turning
13. tor which then pumps water out of the impeller assembly The intake U tube directs the flow of unfiltered water through filter inserts to trap particles debris and purify the water CYCLEGUARD MULTI STAGE FILTRATION SYSTEM Provides optimal Mechanical Chemical and Biological filtration ie A healthy aquarium requires beneficial bacte ria Invisible and harmless beneficial bacteria are essential in the removal of toxic ammonia and nitrite With cartridge filtration systems when you throw away the cartridge you throw away beneficial bacteria It can take weeks for the bacteria to recolonize resulting in a stressful environment The AquaClear multi stage filtration system is different Only one of three filtration components is changed at a time This ensures that significant amounts of beneficial bacteria remain There is never a sudden depletion of bacteria so biological filtration remains at highly effective levels Stage 1 Mechanical Foam Filter Insert AquaClear Foam Filter Inserts perform mechanical filtration by trapping particles and debris as they pass through the insert This unique foam designed for use with AquaClear Power Filters features optimal pore size for efficient mechanical and biological filtration Stage 2 Chemical Activated Carbon insert AquaClear Activated Carbon Filter Insert contains 100 premium research grade carbon Premium research grade carbon pro vides large amounts of surf
14. yer a pe Instruction Manual Models 20 30 50 70 and 110 English IMPORTANT SAFEGUARDS WARNING To guard against injury basic safety precautions should be observed including the following 1 For the complete enjoyment use and understanding of this product READAND FOLLOW ALL SAFETY INSTRUCTIONS and all important notices on the AquaClear Power Filter before using Failure to do so may result in damage to the unit 2 DANGER To avoid possible electrical shock special care should be taken since water is employed in the use of this equipment For each of the following situations do not attempt repairs yourself return the AquaClear Power Filter to an authorized service facility for service or discard the appliance If the AquaClear Motor Unit falls into the water DO NOT reach for it First unplug it and then retrieve it If any of the electrical components of the AquaClear Power Filter gets wet unplug it immediately ll If the AquaClear Motor Unit shows any sign of abnormal water leakage or if RCD or GFCI Ground Fault Current Interrupter switches off disconnect the power supply cord from mains and remove pump from water Carefully examine the AquaClear Power Filter after installation It should not be plugged in if there is water on parts not intended to be wet IV Do not operate any appliance if it has a damaged cord or plug or if it is malfunctioning or if it is dropped or damaged in any man ner The

Download Pdf Manuals

image

Related Search

Related Contents

機械工具NAVI 2009~2010  Télécharger  HBZ4900 - Horizon Hobby  試験計測用航空機 (機体) 補用品の契約希望者募集要領    Manuais - Sanindusa  Ministerieel besluit - Federale Overheidsdienst Binnenlandse Zaken  STM8L15LPBOARD low-power demonstration board    C4FM FDMA - Yaesu.com  

Copyright © All rights reserved.