Field-IQ chapter, FmX Integrated Display User Guide

image

Contents

1. When adding or editing a sensor enter the following information Setting Description Sensor Type Select from e Air pressure vacuum e Liquid pressure e NH3 pressure e Bin level e RPM e Gate Height Name Use the virtual keyboard to enter a name for the sensor Sensor Setup Field IQ module Select the Field IQ module that is controlling this sensor Input location Specify which wire is controlling the sensor 270 FmX Integrated Display User Guide The Field IQ Plugin 10 Operation tab Field IQ Setup oe on Control Cancel OK Rate Control Row Monitoring Sensors Operation Jump Start Speed 5 00 mph Shutoff Speed 0 36 mph Minimum Override Speed 0 00 mph When Outside Field Boundary wich Off Material Controlled By wich Boxes etna E boxes If you do not select Switch Boxes you will be unable to calibrate Rate Snapping 614i your material Setting Jump Start Speed This setting controls the speed to be used when the Field IQ master switchbox Master switch is put in the jump start position This manual override option can be used to operate the system when the vehicle is stationary Jump start is also used when GPS has become unavailable Shutoff Speed This setting controls when to shut the system down if the implement drops below the specified speed Minimum Override Speed This setting maintains the application
2. Field IQ Setup Cancel Material Layout Bin Tank Setup Row Offset Setup Gate Setup Next gt gt Setting Description Bin Tank Setup Allows the system to track how much material is left in the bin tank and provides a warning when the bin tank needs to be refilled Adjust the settings for e Status On The system will track the bin tank level and provide warnings Off The system will not track the bin tank level or provide warnings e Capacity Units Select Default Units or Bushels Default units will vary according to the type of material that is being applied e Bin Capacity The amount the tank bin holds when full Note Markings on tank bin may not be accurate e Current Volume Current volume of the product in the tank e Partial Refill The amount of material that will be added to the bin tank during a partial refill e Warning Level A warning will appear on your screen when your bin tank reaches a set threshold e Refill Tank Bin Refills the tank bin to capacity e Partial Refill Tank Bin Refills the tank bin to the amount specified in the Partial Refill field 278 FmX Integrated Display User Guide The Field IQ Plugin 10 Setting Description Row Offset Setup Row Offset Setup provides additional tuning by detailing where the material will be applied in relation to the vehicle Increase coverage accuracy by selecting one or two offsets
3. Tap To Add add and set up a new material Edit view or edit the details of an existing material Delete delete an existing material 3 When you tap Add or Edit the Field JQ Setup Wizard appears The wizard contains seven tabs The information that appears on each tab depends on the operation you are setting up Enter accurate information into each field of the wizard 232 FmxX Integrated Display User Guide The Field IQ Plugin 10 Setting up the Field IQ system for Planting Make sure that you have set your implement to Planter and that you have configured the implement see Configuring the display page 75 In the Material Overview screen tap New to open the Field IQ Setup Wizard The Wizard contains the following seven tabs For information on this tab See Material page 233 Layout page 234 Section Control page 236 Rate Control page 238 Row Monitoring page 241 Sensors page 242 Operation page 243 Material tab Enter information about the material you want to set up Field IQ Setup oe Material Rate Control Row Monitor 4 gt Layout Section Control Material Type ES Row Crop Seed w Material Name com Material Details Setup Application Rate Setup Rate Alarms Setup Cancel OK Setting Description Material Type Select your Field IQ application type Note If spraying chemicals use the liquid fertilizer setting e Ro
4. 7 Tap OK Enter a value for each of the following Flow Meter Type select an option from the drop down list Flowmeter Calibration enter the number from the flow meter tag MinFlow enter the required minimum flow rate for the system Use this setting to keep the control valve and flow meter above the minimum operating level 8 Tap Run Calibration and then follow the on screen instructions FmX Integrated Display User Guide 273 10 The Field IQ Plugin 9 Ifused select the connector that the pressure sensor is connected to and then enable the sensor 10 Tap Run Calibration and then follow the on screen instructions 11 Tap OK to return to the Configuration screen 12 Select the Field IQ plugin tab and then tap Diagnostics The following screen appears 13 To enable the sections tap the numbered section tabs above each of the section icons 14 Enter a value for each of the following Target Rate The required rate for the rate switch Speed 274 FmX Integrated Display User Guide The Field IQ Plugin 10 15 Operate the sprayer and check value shown for the Applied Rate If necessary adjust the Aggressiveness setting to achieve the desired rate Field IQ Diagnostics Go FmX Integrated Display User Guide 275 10 The Field IQ Plugin Calibrating the implement lift switch 1 2 3 4 From the Field IQ Calibration screen select the Implement Lift option Raise the implement and then tap N
5. on Control Cancel OK Rate Control Row Monitoring Sensors Operation Jump Start Speed 5 00 mph Shutoff Speed 0 36 mph Minimum Override Speed 0 00 mph When Outside Field Boundary wich Off Material Controlled By wich Boxes etna E boxes If you do not select Switch Boxes you will be unable to calibrate Rate Snapping 614i your material Setting Jump Start Speed This setting controls the speed to be used when the Field IQ master switchbox Master switch is put in the jump start position This manual override option can be used to operate the system when the vehicle is stationary Jump start is also used when GPS has become unavailable Shutoff Speed This setting controls when to shut the system down if the implement drops below the specified speed Minimum Override Speed This setting maintains the application rate when the implement s actual speed drops below the value entered It is used to ensure consistent material flow during slow speeds When Outside Field Boundary Switch off The system will not apply outside the boundary area Operate The system will apply outside the boundary area Material Controlled By Rate Snapping Enabled The material is tied to the Master Switch Box and cannot be controlled individually Disabled The Material is not tied to the Master Switch box and is controlled by virtual buttons on the Run screen
6. Description Rate Control On The system sets the target rate Off Section switching only Rate Control Module Location Tap Setup to configure the rate control module s their location on the implement and the width they will control Drive Setup When you tap Drive Setup a screen appears with the following tabs e Valve Setup e Feedback Setup e Advanced The tabs are explained in more detail on the following pages 238 FmX Integrated Display User Guide Drive Setup Valve Setup tab Drive Setup The Field IQ Plugin 10 Setting Description Valve Type Servo 2 wire standard servo valve Fast Servo 4 wire servo valve PWM 2 wire PWM valve commonly used to control hydraulic flow to the pump Hardi Bypass Used on Hardi sprayers equipped with 3 way section valves that return flow to the tank when the boom section is off Pump Servo commonly used for anhydrous application Linear Actuator A valve that creates a linear motion as opposed to a rotary motion Electric over Hydraulic A valve that uses electric current to power the solenoid FmX Integrated Display User Guide 239 10 The Field IQ Plugin Feedback Setup tab Drive Setup Setting Description Flow Meter Type Select the type of flow meter that is connected Flowmeter Calibration Enter the number from the flow meter tag Min Flow Enter the required minimum flow rate for the sys
7. Offset and the front row Section Control tab Adjust the section control settings Field IQ Setup oe a gt Material Layout Section Control Rate Control Sensors Section Control fon v Section Control Module Location Senp Section Control Setup Fence Nozzles rine E peoa M Cancel OK Setting Description Section Control On Enable section control for the current material Off Disable section control for the current material Rate as Section When a rate controller turns on or off the section turns on or off Link to Material See Linking Materials page 230 FmX Integrated Display User Guide 265 10 The Field IQ Plugin Setting Description Section Control Module Setup Tap Setup to configure the section control module s their location on the implement and the number of sections they will control Assign the Field IQ module to the correct location to ensure it controls the correct section e Number of Modules Enter the number of Field IQ section control modules you will use e Module Select the module number that corresponds to each section e Number of Sections Assign the number of sections that each module will control e Section Grouping Assign the rows that are in each section e Advanced Wire Assignment Every section is controlled by a specific wire on each Field IQ module Use this setting to specify which module each s
8. Row offsets are measured from the Application Offset that is entered in the Measurements tab of the Implement Configuration wizard See Implement Configuration Measurements page 165 e Number of row offsets Use 1 row offset when coverage is applied at a single location Use two row offsets when planting singulated seed with staggered implements e Row Offset 1 row offset Enter the distance between the Application Offset and the row e Rear Row Offset 2 row offset Enter the distance between the Application Offset and the rear row e Front Row Offset 2 row offset Enter the distance between the Application Offset and the front row Gate Setup Enter the following measurements e Gate Height e Gate Width e Drag chain length per turn of the drag shaft Section Control tab Adjust the section control settings Field IQ Setup Material Cancel Layout Section Control seca sik Section Control Module Location pete Section Control Setup Next gt gt Setting Description Section Control On Enable section control for the current material Off Disable section control for the current material Rate as Section When a rate controller turns on or off the section turns on or off Link to Material See Linking Materials page 230 FmX Integrated Display User Guide 279 10 The Field IQ Plugin Setting Description Section Control Module
9. turn off the master switch In the Number of Seed Meter Revolutions enter a value and then tap Start The higher the number of revolutions the more accurate the calibration Trimble recommends 5 to 10 revolutions Follow the on screen prompts of operating the master switch After the system turns the specified number of revolutions enter the number of seeds dispensed per row and then tap Continue The next screen shows the minimum and maximum speeds for the target rate specified Tap OK and then either press Test to repeat the calibration or tap OK to continue 9 Select the Limits tab to show an overview of the limits that are set Planter Calibration 8 Rate Controller 4937801425 Calibrate Limits Speed Limits Rate Min Speed Max Speed Target Rate 1 30 00 kS a 2 99 mph 8 96 mph Target Rate 2 24 00 kS a 3 73 mph 11 20 mph Jump Start Speed Min Rate Max Rate 6 00 mph 14 93 kS a 44 78 kS a Cancel OK 10 Tap OK 11 Repeat Step 1 through Step 10 for other Rawson Control Modules that need calibration FmxX Integrated Display User Guide The Field IQ Plugin 10 Hydraulic test The purpose of this test is to exercise the hydraulics to establish whether there is sufficient oil flow to run the system 1 From the Field IQ Calibration screen tap Hydraulic Test A CAUTION Moving parts during this operation Ensure the implement is safe to operate 2 Tap Next 3 Enter the initial mot
10. Page 1 of the plugin tab Page 2 of the plugin tab 20000000 00000000M a Bin Level Low Bin Level Low Average Spacing 5 80 Quality Spacing 95 8 Please check the placement of the callouts in page 2 Wild guess on my part Description The name of the material you are viewing Tap to turn the material on or off Tap to turn auto section control on or off 0 0 0 Current information about the event FmX Integrated Display User Guide 229 10 The Field IQ Plugin Description Target rate Tap the button to select if Target 1 or Target 2 is shown or to select Manual to turn the Targt rate off Tap the button to decrease the Target rate by 1 tap the button to increase the Target rate by 1 Tap to go to page 1 or to page 2 of the plugin tab Tap to return to the main plugin tab Tap to go to the Row Details tab Current sensor status 6 oo 9 9 Depending on the material the following buttons appear Bin Tap to go to the Virtual Bin Tank Setup screen where you can adjust the bin setting Seed Disc Tap to fill the seed disk Arm Pump Tap to enable Field IQ to control the pump Gate Setup Tap to go to the Gate Setup screen Density Tap to go to the Density screen where you can enter the density of the current product There ar various shades of green yellow and red These shades reflec
11. and so on Before starting the Field IQ plugin setup on the FmX integrated display ensure that all components of the system are installed on the vehicle and implement the Field IQ plugin has been added to the FmxX integrated display configuration See Adding or removing a plugin page 172 the implement has been set up and configured for the appropriate operation such as planting or spraying See Chapter 7 Implement Configuration The Field IQ Setup Wizard The FmX integrated display contains a Field IQ Setup Wizard that steps you through setting up the Field IQ system You must enter accurate values on each screen of the wizard to ensure that the system operates correctly To navigate the wizard Tap Next to proceed to the next screen Tap Back to return to the previous screen To enter a number or a name tap in the blank field to open the virtual keypad or keyboard FmX Integrated Display User Guide 231 10 The Field IQ Plugin Note When you have completed the setup wizard once the Next button is replaced with OK You can then view each tab by tapping it on the screen To access the Field IQ setup wizard 1 Inthe Configuration screen select the Field IQ plugin and then tap Setup The Material Overview screen appears Material Overview Corn 1 The Material Overview screen displays the materials that are currently set up to be applied with the Field IQ system 2 Do the following
12. drops below the specified speed Minimum Override Speed This setting maintains the application rate when the implement s actual speed drops below the value entered It is used to ensure consistent material flow during slow speeds When Outside Field Boundary Switch off The system will not apply outside the boundary area Operate The system will apply outside the boundary area Material Controlled By Rate Snapping Enabled The material is tied to the Master Switch Box and cannot be controlled individually Disabled The Material is not tied to the Master Switch box and is controlled by virtual buttons on the Run screen Enabled Shows the applied rate the same as the target rate if the applied rate is within 10 of the target rate Disabled Shows the actual applied value Material Setup Complete screen When you have completed setting up a new material the Material Setup Complete screen appears You can select Add another material You are returned to the start of the Field JQ Setup Wizard e Finish Setup You are returned to the Material Overview screen FmX Integrated Display User Guide 285 10 The Field IQ Plugin Calibrating the modules The Field IQ Calibration option only appears on the Configuration screen if you have at least one Field IQ Rate and Section control module installed 1 From the Configuration screen select the Field IQ plugin and then tap Calibrate 2 From th
13. increase the On Latency value to compensate the delay and the system will turn on in advance Off Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the Off Latency value to compensate for the delay and the sytem will turn off after the set number of seconds Start Overlap Enter the distance of intentional swath overlap when entering a previously applied area The higher the number the greater the overlapped area End Overlap Enter the distance of intentional swath overlap when exiting a previously applied area The higher the number the greater the overlapped area Coverage Switching Overlap Enter the percentage of the section width for intentional swath overlap The higher the number the greater the overlapped area before the section is turned off Boundary Switching Overlap Enter the percentage of the section width for intentional overlap of a boundary The higher the number the greater the overlapped area into the boundary area 280 FmX Integrated Display User Guide Drive Setup Valve Setup tab Drive Setup The Field IQ Plugin 10 Setting Description Valve Type Servo 2 wire standard servo valve Fast Servo 4 wire servo valve PWM 2 wire PWM valve commonly used to control hydraulic flow to the pump Hardi Bypass Used on Hardi sprayer
14. individually Disabled The Material is not tied to the Master Switch box and is controlled by virtual buttons on the Run screen Enabled Shows the applied rate the same as the target rate if the applied rate is within 10 of the target rate Disabled Shows the actual applied value Material Setup Complete screen When you have completed setting up a new material the Material Setup Complete screen appears You can select Add another material You are returned to the start of the Field JQ Setup Wizard e Finish Setup You are returned to the Material Overview screen 302 FmxX Integrated Display User Guide The Field IQ Plugin 10 Calibrating the modules Calibrate the modules to ensure that your system performs at the level you require The Field IQ Calibrate option only appears on the Configuration screen if you have at least one Field IQ Rawson control module or Rate control module set up to control the rate 1 2 From the Configuration screen select the Field IQ plugin and then tap Calibrate From the Field IQ Calibration screen select the operation under the Module that you would like to calibrate The message Not calibrated appears at the end of the modules that need calibration Note If you have an implement lift switch calibrate it first See Calibrating the implement lift switch page 248 Field IQ Calibration 2 ws 3 Select Drive Calibration and then tap OK The Drive Calibratio
15. rate when the implement s actual speed drops below the value entered It is used to ensure consistent material flow during slow speeds When Outside Field Boundary Switch off The system will not apply outside the boundary area Operate The system will apply outside the boundary area Material Controlled By Rate Snapping Enabled The material is tied to the Master Switch Box and cannot be controlled individually Disabled The Material is not tied to the Master Switch box and is controlled by virtual buttons on the Run screen Enabled Shows the applied rate the same as the target rate if the applied rate is within 10 of the target rate Disabled Shows the actual applied value Material Setup Complete screen When you have completed setting up a new material the Material Setup Complete screen appears You can select Add another material You are returned to the start of the Field JQ Setup Wizard e Finish Setup You are returned to the Material Overview screen FmxX Integrated Display User Guide 271 10 The Field IQ Plugin Calibrating the spraying modules The Field IQ Calibrate option only appears on the Configuration screen if you have at least one Field IQ Rate and Section control module installed 1 From the Configuration screen select the Field IQ plugin and then tap Calibrate 2 From the Field JQ Calibration screen select the Rate and Section Control Module to be calibrated The m
16. row offset when coverage is applied at a single location Use two row offsets when planting singulated seed with staggered implements e Row Offset 1 row offset Enter the distance between the Application Offset and the row e Rear Row Offset 2 row offset Enter the distance between the Application Offset and the rear row e Front Row Offset 2 row offset Enter the distance between the Application Offset and the front row Section Control tab Adjust the section control settings Field IQ Setup Material Cancel Layout Section Control Section Control Module Location Senp Section Control Setup Next gt gt Setting Description Section Control On Enable section control for the current material Off Disable section control for the current material Rate as Section When a rate controller turns on or off the section turns on or off Link to Material See Linking Materials page 230 296 FmxX Integrated Display User Guide The Field IQ Plugin 10 Setting Description Section Control Module Setup Tap Setup to configure the section control module s their location on the implement and the number of sections they will control Assign the Field IQ module to the correct location to ensure it controls the correct section Number of Modules Enter the number of Field IQ section control modules you will use Module Select the module number that
17. that is being applied Bin Capacity The amount the tank bin holds when full Note Markings on tank bin may not be accurate Current Volume Current volume of the product in the tank Partial Refill The amount of material that will be added to the bin tank during a partial refill Warning Level A warning will appear on your screen when your bin tank reaches a set threshold Refill Tank Bin Refills the tank bin to capacity Partial Refill Tank Bin Refills the tank bin to the amount specified in the Partial Refill field 264 FmxX Integrated Display User Guide The Field IQ Plugin 10 Setting Description Row Offset Setup Row Offset Setup provides additional tuning by detailing where the material will be applied in relation to the vehicle Increase coverage accuracy by selecting one or two offsets Row offsets are measured from the Application Offset that is entered in the Measurements tab of the Implement Configuration wizard See Implement Configuration Measurements page 165 e Number of row offsets Use 1 row offset when coverage is applied at a single location Use two row offsets when planting singulated seed with staggered implements e Row Offset 1 row offset Enter the distance between the Application Offset and the row e Rear Row Offset 2 row offset Enter the distance between the Application Offset and the rear row e Front Row Offset 2 row offset Enter the distance between the Application
18. the section s assigned to it are commanded to be off When the Automatic Manual section control switch is in the Manual position e Ifthe section switch is in the on up position the section s assigned to it are commanded to be on This overrides the FmX integrated display and coverage logging is ignored e Ifthe section switch is in the off down position the section s assigned to it are commanded to be off This overrides the FmX integrated display and coverage logging is ignored The LED has the following status indicators e Green The unit is powered and is communicating with the FmX integrated display e Yellow The unit is initializing communications with the FmX integrated display e Red The unit is powered but not communicating with the FmX integrated display Field IQ Run screen The Field IQ Run screen has three pages e Page 1 shows current information about an event and allows you to manipulate the materials and sections e Page 2 shows additional information on the current event e Page 3 shows row details Click the arrow key to move between the pages FmxX Integrated Display User Guide 227 10 The Field IQ Plugin The following shows the Field IQ run screen with the main plugin screen Fal 0290000000000 09000000000 G eo Frarget 30 00 Da Actual 0 00 kS a Target n a Actual 0 00 Ibs a 1 Target n a Actual 0 00 Ibs a a T Target n a Actual 0 0
19. 0 Ibs a Lo tiquia A Target n a al 0 00fal a a AAAAAAAAAAAAAAAAAALAL Feature Description Materials list Up to 6 materials are listed The current Target and Actual rates are shown for each material Tap a material to show details of that material see following page Field IQ Plugin icon Mapping Information Change the mapping information that appears on your screen See Mapping tab information tab page 48 Row Status Indicator There are various shades of green yellow and red These shades reflect how tab far off target the rows are applying Green Rows are applying on target Red Rows are applying off target Black Rows have been manually turned off White Rows have been turned off automatically by the system Field IQ Status tab Shows the engage status of each row on the implement Green Engaged Gray Section closed due to overlap Red Not engaged or section manually turned off Tap the blue arrows to toggle between the Row Status Indicator tab and the Field IQ Status tab Engage button Green Auto guidance engaged Gray Auto guidance can be engaged Red Auto guidance cannot be engaged 228 FmX Integrated Display User Guide The Field IQ Plugin 10 Feature Description Logging button Green Logging enabled Red Logging Tap a material in this example Corn to view more details
20. 2 wire electric motor turns a ball or butterfly valve to increase or decrease flow for example a Raven standard servo Hardi bypass scenario Most commonly used on Hardi sprayers equipped with 3 way section valves that return flow to tank when the boom section is off Plumbing Inline Valve is in the solution line going to the boom The valve opens to increase application rate Bypass Valve is in the Return to Tank line The valve closes to increase the application rate Valve Behavior on Sections Closed Close When all sections are off the control valve returns to the closed position Lock in Last Position When all sections are off the control valve remains in the last position This setting allows the system to return to the target rate faster Auxiliary Valve If you have an Auxiliary Valve installed select one of the following Master Valve closes when the system is turned off Dump Valve opens to dump flow to return line when the system is turned off Pump Disarming Switch Enable Select this option if you have a Pump Disarming Switch installed 5 Select the Control tab Rate and Section Controller Valve Calibration Control Allowable Error Gain Minimum Response Cancel FmX Integrated Display User Guide 287 10 The Field IQ Plugin 6 Enter the following values Allowable Error Gain Minimum Response Note For information about the appropr
21. Advanced Wire Assignment Every section is controlled by a specific wire on each Field IQ module Use this setting to specify which module each section is wired to Section Control Tap Setup to adjust settings for each section control module Section Control Type Select the type of section control for each module Off When Stopped When set to Yes the control valve will close when ground speed reaches 0 with the master switch position in On When set to No the control valve will hold its last position when the master switch is shut off and ground speed reaches 0 if the vehicle is a clutch operated planter set this option to No so that you can continue planting when the vehicle is stopped Otherwise select Yes On Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the On Latency value to compensate the delay and the system will turn on in advance Off Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the Off Latency value to compensate for the delay and the sytem will turn off after the set number of seconds Start Overlap Enter the distance of intentional swath overlap when entering a previously applied area The higher the nu
22. CHAPTER The Field 1Q Plugin In this chapter This chapter describes how to calibrate f configure and operate the Field IQ crop input m Introduction control system with the FmX integrated display m Installing the Field IQ hardware m Field IQ master switch box functions m Field IQ 12 section switch box optional m Setting up the Field IQ system for Planting m Setting up the Field IQ system for Air Seeding m Setting up the Field IQ system for Spraying m Setting up the Field IQ system for Spreading m Setting up the Field IQ system for Anhydrous m Using the Diagnostics tab FmX Integrated Display User Guide 223 10 The Field IQ Plugin Introduction When the Field IQ plugin is installed the FmX integrated display can control planters sprayers air seeders liquid strip till tool bars and spinner spreaders It can perform automatic section control using Tru Count air clutches boom valves LiquiBlock and various section control devices while also controlling rates using a prescription with Rawson drives servo valves PWM valves and various flow control devices This chapter explains how to configure and use the Field IQ plugin Different functions of the plugin can be configured and controlled by Field IQ as follows Application Main functions Planter e Seed Section Control of up to 48 individual rows Field IQ section control module s needed using Tru Count air clutches e Seed Rate Cont
23. Edit Sensor Edit or view the settings for an existing sensor Remove Sensor Delete an existing sensor When adding or editing a sensor enter the following information Setting Description Sensor Type Select from e Air pressure vacuum e Liquid pressure e NH3 pressure e Bin level e RPM e Gate Height Name Use the virtual keyboard to enter a name for the sensor Sensor Setup Field IQ module Select the Field IQ module that is controlling this sensor Input location Specify which wire is controlling the sensor 284 FmX Integrated Display User Guide The Field IQ Plugin 10 Operation tab Field IQ Setup oe on Control Cancel OK Rate Control Row Monitoring Sensors Operation Jump Start Speed 5 00 mph Shutoff Speed 0 36 mph Minimum Override Speed 0 00 mph When Outside Field Boundary wich Off Material Controlled By wich Boxes etna E boxes If you do not select Switch Boxes you will be unable to calibrate Rate Snapping 614i your material Setting Jump Start Speed This setting controls the speed to be used when the Field IQ master switchbox Master switch is put in the jump start position This manual override option can be used to operate the system when the vehicle is stationary Jump start is also used when GPS has become unavailable Shutoff Speed This setting controls when to shut the system down if the implement
24. Enabled Shows the applied rate the same as the target rate if the applied rate is within 10 of the target rate Disabled Shows the actual applied value Material Setup Complete screen When you have completed setting up a new material the Material Setup Complete screen appears You can select Add another material You are returned to the start of the Field IQ Setup Wizard e Finish Setup You are returned to the Material Overview screen FmX Integrated Display User Guide 243 10 The Field IQ Plugin Calibrating the modules Calibrate the modules to ensure that your system performs at the level you require The Field IQ Calibrate option only appears on the Configuration screen if you have at least one Field IQ Rawson control module or Rate control module set up to control the rate 1 From the Configuration screen select the Field IQ plugin and then tap Calibrate 2 From the Field JQ Calibration screen select the operation under the Module that you would like to calibrate The message Not calibrated appears at the end of the modules that need calibration Note If you have an implement lift switch calibrate it first See Calibrating the implement lift switch page 248 Field IQ Calibration 3 Select the first module to calibrate and then tap OK The Planter Calibration screen appears 244 FmxX Integrated Display User Guide The Field IQ Plugin 10 In the Seeds Per Disk field enter a value This is t
25. Setup Tap Setup to configure the section control module s their location on the implement and the number of sections they will control Assign the Field IQ module to the correct location to ensure it controls the correct section Number of Modules Enter the number of Field IQ section control modules you will use Module Select the module number that corresponds to each section Number of Sections Assign the number of sections that each module will control Section Grouping Assign the rows that are in each section Advanced Wire Assignment Every section is controlled by a specific wire on each Field IQ module Use this setting to specify which module each section is wired to Section Control Tap Setup to adjust settings for each section control module Section Control Type Select the type of section control for each module Off When Stopped When set to Yes the control valve will close when ground speed reaches 0 with the master switch position in On When set to No the control valve will hold its last position when the master switch is shut off and ground speed reaches 0 if the vehicle is a clutch operated planter set this option to No so that you can continue planting when the vehicle is stopped Otherwise select Yes On Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case
26. a The higher the number the greater the overlapped area e Coverage Switching Overlap Enter the percentage of the section width for intentional swath overlap The higher the number the greater the overlapped area before the section is turned off e Boundary Switching Overlap Enter the percentage of the section width for intentional overlap of a boundary The higher the number the greater the overlapped area into the boundary area Fence Nozzles Many setups require a left fence nozzle to be configured even when there is no left fence nozzle For more information refer to your sprayer installation instructions Right Nozzle Wiring 266 FmxX Integrated Display User Guide In you are using an EZ Boom replacement harness select the EZ Boom setting Otherwise select the Field IQ setting Rate Control tab The Field IQ Plugin 10 Adjust the rate control settings Field IQ Setup Setting Description Rate Control On The system sets the target rate Off Section switching only Rate Control Module Location Tap Setup to configure the rate control module s their location on the implement and the width they will control Drive Setup When you tap Drive Setup a screen appears with the following tabs e Valve Setup e Feedback Setup The tabs are explained in more detail on the following pages Number of Nozzles Enter the number of spray nozzles on the sprayer F
27. anular Fertilizer e Anhydrous Material Name Use the virtual keyboard to enter a name for the material Application Rate Rates tab Adjust the following Rate settings e Target Rate This setting controls the volume that the implement supplies when the Rate switch is in position 1 e Target Rate 2 This setting controls the volume that the implement supplies when the Rate switch is in position 2 e Rate Increment When the Rate switch is in the Rate 1 or Rate 2 position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Manual Rate Increment When the Rate switch is in the Manual position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Minimum Rate This setting is the minimum rate that will be applied e Maximum Rate This setting is the maximum rate that will be applied Units tab Adjust the following Unit settings e Seeds Per Pound Enter the number of seeds per pound of the current material e Target Rate Units Choose what units your target rate will apply e Bushel Weight Enter the bushel weight of the current material FmX Integrated Display User Guide 277 10 The Field IQ Plugin Layout tab Enter information about the implement that will be used to apply the material
28. ap H 2 From the Current Configurations screen configure the display vehicle implement settings and then tap OK 3 From the Field Selection screen select the required client farm field event settings and then tap OK Using the Diagnostics tab From the Configuration screen select the Field IQ plugin and then tap Diagnostics Field IQ Diagnostics The Operations tab displays the current status of e Control Mode Auto or Manual e Rate Switch Mode Manual Rate 1 or Rate 2 e Master Switch Off On or Jump Start This screen also enables you to manually adjust e Bin Level Enter a new value or select Refill Tank FmX Integrated Display User Guide 305 10 The Field IQ Plugin e Target Rate Decrease or increase e Speed Decrease or increase e Switches If you are using the optional Field IQ individual section switch box this screen indicates which switches have been assigned to each section To test this flip each switch in the section switch box The section it is assigned to appears gray e View Error Log Shows all the errors that have occurred since the error log was cleared e Section Test The system begins a sequence of engaging each section and groups of sections The Hardware tab displays the connected Field IQ CAN modules and the following attributes Serial number e Position on the implement e Firmware version e Status of CAN connection e Tx Rx number of packets e Errors associated
29. as become unavailable Shutoff Speed This setting controls when to shut the system down if the implement drops below the specified speed Minimum Override Speed This setting maintains the application rate when the implement s actual speed drops below the value entered It is used to ensure consistent material flow during slow speeds When Outside Field Boundary Switch off The system will not apply outside the boundary area Operate The system will apply outside the boundary area Material Controlled By Rate Snapping Enabled The material is tied to the Master Switch Box and cannot be controlled individually Disabled The Material is not tied to the Master Switch box and is controlled by virtual buttons on the Run screen Enabled Shows the applied rate the same as the target rate if the applied rate is within 10 of the target rate Disabled Shows the actual applied value Material Setup Complete screen When you have completed setting up a new material the Material Setup Complete screen appears You can select Add another material You are returned to the start of the Field JQ Setup Wizard e Finish Setup You are returned to the Material Overview screen FmX Integrated Display User Guide 259 10 The Field IQ Plugin Calibrating the modules Calibrate the modules to ensure that your system performs at the level you require The Field IQ Calibrate option only appears on the C
30. corresponds to each section Number of Sections Assign the number of sections that each module will control Section Grouping Assign the rows that are in each section Advanced Wire Assignment Every section is controlled by a specific wire on each Field IQ module Use this setting to specify which module each section is wired to Section Control Tap Setup to adjust settings for each section control module Section Control Type Select the type of section control for each module Off When Stopped When set to Yes the control valve will close when ground speed reaches 0 with the master switch position in On When set to No the control valve will hold its last position when the master switch is shut off and ground speed reaches 0 if the vehicle is a clutch operated planter set this option to No so that you can continue planting when the vehicle is stopped Otherwise select Yes On Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the On Latency value to compensate the delay and the system will turn on in advance Off Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the Off Latency value to compensate for the delay and the syte
31. e Field IQ Calibration screen select the Rate and Section Control Module to be calibrated The message Not calibrated appears at the end of the modules that need calibration The following screen appears Field 1Q Calibration amp Rate and Section Control Module 5015561943 Valve Calibration Flow Calibration Pressure Calibration 3 Tap Valve Calibration The following screen appears Rate and Section Controller Valve Calibration Valve Control Valve Type Servo v Plumbing v Valve Behavior On Sections flock in tast Postion Closed Auxiliary Valve Disabled v Pump Disarming Switch Disabled v Cancel OK 286 FmX Integrated Display User Guide The Field IQ Plugin 10 4 Select the Valve tab and then select the appropriate value for each field For this field Select one of the following options Valve Type Pump Servo The Pump Servo setting controls an electric motor which actuates a hydraulic valve As the valve actuates it adjusts the hydraulic flow to the pump This valve adjusts the application rate indirectly PWM The PWM pump setting controls an electric solenoid valve which adjusts the hydraulic flow to the pump This valve adjusts the application rate indirectly Fast Servo A 4 wire electric motor turns a ball or butterfly valve to increase or decrease flow for example a DICKEY john servo Mid Tech servo or Raven Fast Valve Servo A
32. e boom The valve opens to increase application rate Bypass Valve is in the Return to Tank line The valve closes to increase the application rate Valve Behavior on Sections Closed Close When all sections are off the control valve returns to the closed position Lock in Last Position When all sections are off the control valve remains in the last position This setting allows the system to return to the target rate faster 272 FmX Integrated Display User Guide The Field IQ Plugin 10 For this field Select one of the following options Auxiliary Valve If you have an Auxiliary Valve installed select one of the following Master Valve closes when the system is turned off Dump Valve opens to dump flow to return line when the system is turned off Pump Disarming Enable Select this option if you have a Pump Disarming Switch installed Switch 5 Select the Control tab Enter a value for each of the following Allowable Error Gain Minimum Response Note For information about the appropriate values for your sprayer see the Getting Started Guide 6 Tap OK to return to the main calibration screen and then tap Flow Calibration The following screen appears Rate and Section Control Flow Calibration ce Flow Meter Type Raven Flowmeter Calibration Min Flow AN CAUTION Moving parts during this operation Ensure the implement is safe to operate
33. ection is wired to Section Control Tap Setup to adjust settings for each section control module e Section Control Type Select the type of section control for each module e Off When Stopped When set to Yes the control valve will close when ground speed reaches 0 with the master switch position in On When set to No the control valve will hold its last position when the master switch is shut off and ground speed reaches 0 if the vehicle is a clutch operated planter set this option to No so that you can continue planting when the vehicle is stopped Otherwise select Yes e On Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the On Latency value to compensate the delay and the system will turn on in advance e Off Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the Off Latency value to compensate for the delay and the sytem will turn off after the set number of seconds e Start Overlap Enter the distance of intentional swath overlap when entering a previously applied area The higher the number the greater the overlapped area e End Overlap Enter the distance of intentional swath overlap when exiting a previously applied are
34. el ae FmxX Integrated Display User Guide 10 289 10 The Field IQ Plugin 14 Enter the following values Amount of Material to be Dispensed This is the amount dispensed during the calibration Target Rate Target Speed 15 To begin the calibration tap Start and then follow the on screen instructions 16 Select the Limits tab Granular Calibration 17 Enter the following values Minimum RPM Maximum RPM 290 FmxX Integrated Display User Guide The Field IQ Plugin 10 18 Select the nfo tab to view the system s operational limits based on the RPM limits target rates and application width Granular Calibration 7 Ge 19 Tap OK Calibrating the implement lift switch 1 From the Field IQ Calibration screen select the Implement Lift option 2 Raise the implement and then tap Next 3 Lower the implement and then tap Next 4 Tap OK to return to the Field IQ Calibration screen Operating in the field 1 From the Home screen tap A 2 From the Current Configurations screen configure the display vehicle implement settings and then tap OK 3 From the Field Selection screen select the required client farm field event settings and then tap OK FmX Integrated Display User Guide 291 10 Setting up the Field IQ system for Anhydrous 292 The Field IQ Plugin WARNING When you tap the liquid flow calibration Start button the machine will become operational Take all
35. er switch box e Manual Rate Increment When the Rate switch is in the Manual position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Minimum Rate This setting is the minimum rate that will be applied e Maximum Rate This setting is the maximum rate that will be applied Units tab Adjust the following Unit settings e Seeds Per Pound Enter the number of seeds per pound of the current material e Target Rate Units Choose what units your target rate will apply e Bushel Weight Enter the bushel weight of the current material FmX Integrated Display User Guide 263 10 The Field IQ Plugin Layout tab Enter information about the implement that will be used to apply the material Field IQ Setup Material Cancel Layout Section Control Rate Control Row Monitor 4 gt Bin Tank Setup Row Offset Setup n Setting Description Bin Tank Setup Allows the system to track how much material is left in the bin tank and provides a warning when the bin tank needs to be refilled Adjust the settings for Status On The system will track the bin tank level and provide warnings Off The system will not track the bin tank level or provide warnings Capacity Units Select Default Units or Bushels Default units will vary according to the type of material
36. essage Not calibrated appears at the end of the modules that need calibration 3 Tap Valve Calibration The following screen appears Rate and Section Controller Valve Calibration Valve Cancel OK Control Valve Type Servo v Plumbing Inline v Valve Behavior On Sections A ceea Lock in Last Position Auxiliary Valve Disabled v Pump Disarming Switch Disabled 4 Select the Valve tab and then select the appropriate value for each field For this field Select one of the following options Valve Type Pump Servo The Pump Servo setting controls an electric motor which actuates a hydraulic valve As the valve actuates it adjusts the hydraulic flow to the pump This valve adjusts the application rate indirectly PWM The PWM pump setting controls an electric solenoid valve which adjusts the hydraulic flow to the pump This valve adjusts the application rate indirectly Fast Servo 4 wire electric motor turns a ball or butterfly valve to increase or decrease flow for example a DICKEY john servo Mid Tech servo or Raven Fast Valve Servo 2 wire electric motor turns a ball or butterfly valve to increase or decrease flow for example a Raven standard servo Hardi bypass scenario Most commonly used on Hardi sprayers equipped with 3 way section valves that return flow to tank when the boom section is off Plumbing Inline Valve is in the solution line going to th
37. ext Lower the implement and then tap Next Tap OK to return to the Field IQ Calibration screen Operating in the field l 2 From the Home screen tap ef From the Current Configurations screen configure the display vehicle implement settings and then tap OK From the Field Selection screen select the required client farm field event settings and then tap OK Setting up the Field IQ system for Spreading Make sure that you have set your implement to Spreading and that you have configured the implement see Configuring the display page 75 In the Material Overview screen tap New to open the Field IQ Setup Wizard The Wizard contains the following seven tabs For information on this tab See Material page 233 Layout page 234 Section Control page 236 Rate Control page 238 Row Monitoring page 241 Sensors page 242 Operation page 243 Material tab 276 FmX Integrated Display User Guide The Field IQ Plugin 10 Enter information about the material you want to set up Field IQ Setup o e a gt Material Layout Section Control Rate Control Sensors Material Type e Granular Fertili gt Material Name oranuiar fertilizer Application Rate Cancel OK Setting Description Material Type Select your Field IQ application type Note If spraying chemicals use the liquid fertilizer setting e Row Crop Seed e Liquid e Granular Seed e Gr
38. he distance between the Application Offset and the row e Rear Row Offset 2 row offset Enter the distance between the Application Offset and the rear row e Front Row Offset 2 row offset Enter the distance between the Application Offset and the front row Section Control tab Adjust the section control settings Field IQ Setup Material Cancel Layout Section Control Section Control Module Location Senp Section Control Setup Next gt gt Setting Description Section Control On Enable section control for the current material Off Disable section control for the current material Rate as Section When a rate controller turns on or off the section turns on or off Link to Material See Linking Materials page 230 252 FmxX Integrated Display User Guide The Field IQ Plugin 10 Setting Description Section Control Module Setup Tap Setup to configure the section control module s their location on the implement and the number of sections they will control Assign the Field IQ module to the correct location to ensure it controls the correct section Number of Modules Enter the number of Field IQ section control modules you will use Module Select the module number that corresponds to each section Number of Sections Assign the number of sections that each module will control Section Grouping Assign the rows that are in each section
39. he implement supplies when the Rate switch is in position 1 e Target Rate 2 This setting controls the volume that the implement supplies when the Rate switch is in position 2 e Rate Increment When the Rate switch is in the Rate 1 or Rate 2 position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Manual Rate Increment When the Rate switch is in the Manual position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Minimum Rate This setting is the minimum rate that will be applied e Maximum Rate This setting is the maximum rate that will be applied Units tab Adjust the following Unit settings e Seeds Per Pound Enter the number of seeds per pound of the current material e Target Rate Units Choose what units your target rate will apply e Bushel Weight Enter the bushel weight of the current material 294 FmxX Integrated Display User Guide Layout tab The Field IQ Plugin 10 Enter information about the implement that will be used to apply the material Field IQ Setup Material Cancel Layout Section Control Rate Control Row Monitor 4 gt Bin Tank Setup Row Offset Setup n Setting Description Bin Tank Setup Allows the
40. he number of seeds each seed disk holds Planter Calibration Rate Controller 4937801425 Calibrate Limits Seeds Per Disk 30 Gear Ratio 6 632 Calculate Calibration Constant 1 000000 Test Fill Meter Cancel OK Enter a value in the Gear Ratio field or tap Calculate If you tap Calculate the following screen appears Gear Ratio Calculator Drive Teeth Driven Teeth Gear Set 1 12 24 Gear Set 2 16 36 Gear Set 3 19 28 Gear Set 4 0 0 Gear Ratio 6 632 Cancel OK Use the Gear Ratio Calculator to determine the planter drive gear ratio and then tap OK The Calibration Constant field contains a calculated value that the system determines during calibration This field allows adjustment for inconsistencies in the seed meters To start out Trimble recommends that you leave the value at 1 000 After the calibration test the system may adjust this number FmX Integrated Display User Guide 245 10 The Field IQ Plugin 7 Place a clean empty container under the rows that contain seeds to capture the seeds dispensed during the calibration AN CAUTION Moving parts during this operation Ensure the implement is safe to operate 246 8 Tap Test a The system asks if you would like to prime the system Tap Yes To to ensure that the seed disk is full the system turns the seed disks one revolution Turn on the master switch to prime the system and then when prompted on screen
41. iate values for your sprayer see the Support Note Field IQ Crop Input Control System For Sprayers and Spreaders 7 Tap OK to return to the main calibration screen and then tap Flow Calibration The following screen appears Granular Calibration ao 2 36 8 Enter the following values Gate Height Setting Note If you entered a gate height measurement during setup you must also enter a measurement here Shaft Encoder Constant 288 FmX Integrated Display User Guide The Field IQ Plugin 9 To calculate the calibration constant tap Calculate The following dialog appears Calibration Constant Calculator Gate Width 1 0 0 Drag Chain Distance Per Rev 2 2 0 Calibration Constant 201 290725 Cancel 7 10 Enter the Gate Width and Drag Chain Distance Per Rev The system calculates the Calibration Constant 11 Tap OK to return to the Granular Calibration Screen 12 Place a clean empty container under the spreader to capture the material dispensed during the calibration and then tap Calibrate AN CAUTION Moving parts during this operation Ensure the implement is safe to operate 13 The Granular Calibration screen appears Granular Calibration Rate Controller 5015561943 Enter the desired amount of material to be dispensed then press Start 100 00 Ibs 200 00 Ibs a 6 00 mph Calibrate Amount of Material to be Dispensed Target Rate Target Speed Canc
42. ield IQ Setup Wizard The Wizard contains the following seven tabs For information on this tab See Material page 233 Layout page 234 Section Control page 236 Rate Control page 238 Row Monitoring page 241 Sensors page 242 Operation page 243 248 FmxX Integrated Display User Guide The Field IQ Plugin 10 Material tab Enter information about the material you want to set up Field IQ Setup Granular Seed Setting Description Material Type Select your Field IQ application type Note If spraying chemicals use the liquid fertilizer setting e Row Crop Seed e Liquid e Granular Seed e Granular Fertilizer e Anhydrous Material Name Use the virtual keyboard to enter a name for the material Material Details Tap Setup to open the Hybrid Setup screen See Logging varieties page 65 FmX Integrated Display User Guide 249 10 The Field IQ Plugin Setting Description Application Rate Rates tab Adjust the following Rate settings e Target Rate This setting controls the volume that the implement supplies when the Rate switch is in position 1 e Target Rate 2 This setting controls the volume that the implement supplies when the Rate switch is in position 2 e Rate Increment When the Rate switch is in the Rate 1 or Rate 2 position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch
43. ified in the Partial Refill field FmX Integrated Display User Guide 235 10 The Field IQ Plugin Setting Description Row Offset Setup Row Offset Setup provides additional tuning by detailing where the material will be applied in relation to the vehicle Increase coverage accuracy by selecting one or two offsets Row offsets are measured from the Application Offset that is entered in the Measurements tab of the Implement Configuration wizard See Implement Configuration Measurements page 165 e Number of row offsets Use 1 row offset when coverage is applied at a single location Use two row offsets when planting singulated seed with staggered implements e Row Offset 1 row offset Enter the distance between the Application Offset and the row e Rear Row Offset 2 row offset Enter the distance between the Application Offset and the rear row e Front Row Offset 2 row offset Enter the distance between the Application Offset and the front row Section Control tab Adjust the section control settings Field IQ Setup Material Cancel Layout Section Control Section Control Module Location Senp Section Control Setup Next gt gt Setting Description Section Control On Enable section control for the current material Off Disable section control for the current material Rate as Section When a rate controller turns on or off the section tur
44. l hydraulic flow to the pump Hardi Bypass Used on Hardi sprayers equipped with 3 way section valves that return flow to the tank when the boom section is off Pump Servo Servo valve commonly used to control hydraulic flow to the pump Linear Actuator A valve that creates a linear motion as opposed to a rotary motion Electric over Hydraulic A valve that uses electric current to control the hydraulic valve output FmX Integrated Display User Guide 255 10 The Field IQ Plugin Feedback Setup tab Drive Setup Setting Description Flow Meter Type Select the type of flow meter that is connected Flowmeter Calibration Enter the number from the flow meter tag Min Flow Enter the required minimum flow rate for the system Use this setting to keep the control valve and flow meter above the minimum operating level 256 FmxX Integrated Display User Guide The Field IQ Plugin 10 Row Monitoring tab Field IQ Setup Setting Description Row Monitoring Disabled Turn row monitoring off Blockage Select this option for air seeding or when applying granular material Seed Count Select this option for precision seeding when planting Setup Row Sensor Enable Turn individual row sensors on or off Row Sensor Wiring Select which wire each row sensor is wired to FmX Integrated Display User Guide 257 10 The Field IQ Plugin Sensors tab Add or edit sensor
45. lay User Guide The Field IQ Plugin 10 Drive Setup Valve Setup tab Drive Setup Setting Description Valve Type Servo 2 wire standard servo valve Fast Servo 4 wire servo valve PWM 2 wire PWM valve commonly used to control hydraulic flow to the pump FmX Integrated Display User Guide 299 10 The Field IQ Plugin Feedback Setup tab Drive Setup Setting Description Flow Meter Type Select the type of flow meter that is connected Flowmeter Calibration Enter the number from the flow meter tag Min Flow Enter the required minimum flow rate for the system Use this setting to keep the control valve and flow meter above the minimum operating level 300 FmX Integrated Display User Guide The Field IQ Plugin 10 Sensors tab Add or edit sensor settings Field IQ Setup vac left Setting Description Add Sensor Add a new sensor Edit Sensor Edit or view the settings for an existing sensor Remove Sensor Delete an existing sensor When adding or editing a sensor enter the following information Setting Description Sensor Type Select from e Air pressure vacuum e Liquid pressure e NH3 pressure e Bin level e RPM e Gate Height Name Use the virtual keyboard to enter a name for the sensor Sensor Setup Field IQ module Select the Field IQ module that is controlling this sensor Input location Specify which wire i
46. m will turn off after the set number of seconds Start Overlap Enter the distance of intentional swath overlap when entering a previously applied area The higher the number the greater the overlapped area End Overlap Enter the distance of intentional swath overlap when exiting a previously applied area The higher the number the greater the overlapped area Coverage Switching Overlap Enter the percentage of the section width for intentional swath overlap The higher the number the greater the overlapped area before the section is turned off Boundary Switching Overlap Enter the percentage of the section width for intentional overlap of a boundary The higher the number the greater the overlapped area into the boundary area FmX Integrated Display User Guide 297 10 The Field IQ Plugin Rate Control tab Adjust the rate control settings Field IQ Setup Setting Description Rate Control On The system sets the target rate Off Section switching only Rate Control Module Location Tap Setup to configure the rate control module s their location on the implement and the width they will control Drive Setup When you tap Drive Setup a screen appears with the following tabs e Valve Setup e Feedback Setup e Advanced The tabs are explained in more detail on the following pages Number of Nozzles Enter the number of spray nozzles on the sprayer 298 FmxX Integrated Disp
47. mX Integrated Display User Guide 267 10 The Field IQ Plugin Drive Setup Valve Setup tab Drive Setup Setting Description Valve Type Servo 2 wire standard servo valve Fast Servo 4 wire servo valve PWM 2 wire PWM valve commonly used to control hydraulic flow to the pump Hardi Bypass Used on Hardi sprayers equipped with 3 way section valves that return flow to the tank when the boom section is off Pump Servo Servo valve commonly used to control hydraulic flow to the pump Linear Actuator A valve that creates a linear motion as opposed to a rotary motion Electric over Hydraulic A valve that uses electric current to control the hydraulic valve output 268 FmxX Integrated Display User Guide The Field IQ Plugin 10 Feedback Setup tab Drive Setup Setting Description Flow Meter Type Select the type of flow meter that is connected Flowmeter Calibration Enter the number from the flow meter tag Min Flow Enter the required minimum flow rate for the system Use this setting to keep the control valve and flow meter above the minimum operating level FmX Integrated Display User Guide 269 10 The Field IQ Plugin Sensors tab Add or edit sensor settings Field IQ Setup vac left Setting Description Add Sensor Add a new sensor Edit Sensor Edit or view the settings for an existing sensor Remove Sensor Delete an existing sensor
48. mber the greater the overlapped area End Overlap Enter the distance of intentional swath overlap when exiting a previously applied area The higher the number the greater the overlapped area Coverage Switching Overlap Enter the percentage of the section width for intentional swath overlap The higher the number the greater the overlapped area before the section is turned off Boundary Switching Overlap Enter the percentage of the section width for intentional overlap of a boundary The higher the number the greater the overlapped area into the boundary area FmX Integrated Display User Guide 253 10 The Field IQ Plugin Rate Control tab Adjust the rate control settings Field IQ Setup Setting Description Rate Control On The system sets the target rate Off Section switching only Rate Control Module Location Tap Setup to configure the rate control module s their location on the implement and the width they will control Drive Setup When you tap Drive Setup a screen appears with the following tabs e Valve Setup e Feedback Setup The tabs are explained in more detail on the following pages 254 FmX Integrated Display User Guide Drive Setup Valve Setup tab Drive Setup The Field IQ Plugin 10 Setting Description Valve Type Servo 2 wire standard servo valve Fast Servo 4 wire servo valve PWM 2 wire PWM valve commonly used to contro
49. n screen appears The Drive Calibration screen has four tabs Tab Description Drive Limits Enter the minimum and maximum flow values Auto Tuning A CAUTION Moving parts during this operation Ensure the implement is safe to operate Follow the on screen instructions to auto tune the system Note Do not perform the auto tuning function if you have loaded a preset configuration file Use the predefined configuration settings appropriate for your vehicle Drive Settings Turn the master switch on and vary the rates Adjust values if needed Info 4 Shows the results and drive limits of your calibration Select Flow Calibration and then tap OK The Flow Calibration screen appears FmX Integrated Display User Guide 303 10 The Field IQ Plugin 5 Inthe Rate and Section Control Flow Calibration screen enter the Flow Meter type the Flow Meter Calibration and the Minimum Flow Rate and Section Control Flow Calibration 6 Tap Run Calibration and then follow the on screen instructions Rate and Section Control Flow Calibration Test 304 FmX Integrated Display User Guide The Field IQ Plugin 10 Calibrating the implement lift switch 1 From the Field IQ Calibration screen select the Implement Lift option 2 Raise the implement and then tap Next 3 Lower the implement and then tap Next 4 Tap OK to return to the Field IQ Calibration screen Operating in the field 1 From the Home screen t
50. necessary precautions to ensure user safety Failure to do so may result in serious injury or death Make sure that you have set your implement to Tillage or Spraying and that you have configured the implement see Configuring the display page 75 In the Material Overview screen tap New to open the Field IQ Setup Wizard The Wizard contains the following seven tabs For information on this tab See Material page 233 Layout page 234 Section Control page 236 Rate Control page 238 Row Monitoring page 241 Sensors page 242 Operation page 243 FmxX Integrated Display User Guide The Field IQ Plugin 10 Material tab Enter information about the material you want to set up Field IQ Setup Lbs Actual N kgs Setting Description Material Type Select your Field IQ application type Note If spraying chemicals use the liquid fertilizer setting e Row Crop Seed e Liquid e Granular Seed e Granular Fertilizer e Anhydrous Material Name Use the virtual keyboard to enter a name for the material Anydrous Units Select the unit of measure e Lbs actual N Pounds kg of nitrogen per acre hectare e Lbs NH3 Pounds kg of anhydrous per acre hectare FmX Integrated Display User Guide 293 10 The Field IQ Plugin Setting Description Application Rate Rates tab Adjust the following Rate settings e Target Rate This setting controls the volume that t
51. ns on or off Link to Material See Linking Materials page 230 236 FmxX Integrated Display User Guide The Field IQ Plugin 10 Setting Description Section Control Module Setup Tap Setup to configure the section control module s their location on the implement and the number of sections they will control Assign the Field IQ module to the correct location to ensure it controls the correct section Number of Modules Enter the number of Field IQ section control modules you will use Module Select the module number that corresponds to each section Number of Sections Assign the number of sections that each module will control Section Grouping Assign the rows that are in each section Advanced Wire Assignment Every section is controlled by a specific wire on each Field IQ module Use this setting to specify which module each section is wired to Section Control Tap Setup to adjust settings for each section control module Section Control Type Select the type of section control for each module Off When Stopped When set to Yes the control valve will close when ground speed reaches 0 with the master switch position in On When set to No the control valve will hold its last position when the master switch is shut off and ground speed reaches 0 if the vehicle is a clutch operated planter set this option to No so that you can continue planting when the vehicle is stopped Otherwise select Ye
52. nt switches Definitions Term Definition Material A product that is controlled by a PWM valve Servo valve or Rawson drive You can use a planter seed liquid granular seed and granular fertilizer all of which have different set up parameters Section A number of rows or spray nozzles that are controlled by existing shut off valve Tru Count air clutches or Tru Count LiquiBlock valves A section can have either a single row nozzle or multiple rows nozzles depending on how the system is set up Row The individual row unit which seed comes from on the planter This can be controlled individually as a single row section or as a group with other rows in a multiple row section 224 FmxX Integrated Display User Guide The Field IQ Plugin 10 Units of measure Type Unit Symbol Description Seed Metric kS ha Thousands of seeds per hectare US Imperial kS a Thousands of seeds per acre Granular seed Metric kg ha Kilograms of seed per hectare US Imperial Ibs a Pounds of seed per acre Liquid application Metric L ha Liters per hectare US Imperial Gal a Gallons per acre Granular fertilizer Metric kg ha Kilograms of fertilizer per hectare US Imperial Ibs a Pounds of fertilizer per acre Installing the Field IQ hardware For information on installing the Field IQ crop input control system on your implement refer to e Field IQ Platform Installation Instruc
53. on your master switch box e Manual Rate Increment When the Rate switch is in the Manual position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Minimum Rate This setting is the minimum rate that will be applied e Maximum Rate This setting is the maximum rate that will be applied Rate Alarms Units tab Adjust the following Unit settings e Seeds Per Pound Enter the number of seeds per pound of the current material e Target Rate Units Choose what units your target rate will apply e Bushel Weight Enter the bushel weight of the current material Tap Setup to set alarm thresholds and adjust the way seed statistics are calculated e Blockage Sensitivity Alarm When less than this amount of material is sensed for the number of seconds given 250 FmxX Integrated Display User Guide Layout tab The Field IQ Plugin 10 Enter information about the implement that will be used to apply the material Field IQ Setup Material Cancel Layout Section Control Rate Control Row Monitor 4 gt Bin Tank Setup Row Offset Setup n Setting Description Bin Tank Setup Allows the system to track how much material is left in the bin tank and provides a warning when the bin tank needs to be refilled Adjust the settings for Status On The system
54. onfiguration screen if you have at least one Field IQ Rawson control module or Rate control module set up to control the rate 1 From the Configuration screen select the Field IQ plugin and then tap Calibrate 2 From the Field IQ Calibration screen select the operation under the Module that you would like to calibrate The message Not calibrated appears at the end of the modules that need calibration Note Calibration screens will vary slightly if you are using a linear actuator Note Before priming the system the Automatic Manual Switch on the master switch box must be in the manual position Note If you have an impelement lift switch calibrate it first See Calibrating the implement lift switch page 248 Field IQ Calibration al i 6 a Flow Calibration 3 Select Drive Calibration and then tap OK The Drive Calibration screen appears The Drive Calibration screen has four tabs Tab Description Drive Limits Enter the minimum and maximum flow values Auto Tuning A CAUTION Moving parts during this operation Ensure the implement is safe to operate Follow the on screen instructions to auto tune the system Note Do not perform the auto tuning function if you have loaded a preset configuration file Use the predefined configuration settings appropriate for your vehicle Drive Settings Info Turn the master switch on and vary the rates Adjust values if needed Show
55. or RPM The default setting is 300 Trimble also recommends that you test the motor RPM at 100 to ensure that the drive runs smoothly at slow speeds 4 Tap Start The next screen provides the status of each motor Field IQ Hydraulic Test Ge No Error The test was successful Motor Stalled The motors did not have sufficient oil flow ensure the correct orifice size is installed for each motor For more information refer to the Rawson System Installation Instructions Disconnected The Rawson Control Module cannot communicate with the motor 6 Tap Stop to return to the Field IQ Calibration screen FmX Integrated Display User Guide 247 10 The Field IQ Plugin Calibrating the implement lift switch 1 2 3 4 From the Field IQ Calibration screen select the Implement Lift option Raise the implement and then tap Next Lower the implement and then tap Next Tap OK to return to the Field IQ Calibration screen Operating in the field l 2 From the Home screen tap ef From the Current Configurations screen configure the display vehicle implement settings and then tap OK From the Field Selection screen select the required client farm field event settings and then tap OK Setting up the Field IQ system for Air Seeding Make sure that you have set your implement to Seeder and that you have configured the implement see Configuring the display page 75 In the Material Overview screen tap New to open the F
56. rol using up to 4 Rawson drives to change seed population Field IQ Rawson Control Module s needed e Liquid Fertilizer Control of up to 48 individual liquid nozzles Field IQ section control module s needed using Tru Count LiquiBlock valves e Variety tracking Sprayer e Liquid Rate Control using either a PWM or Servo control valve e Liquid Section Control of up to 48 individual spray nozzles Field IQ Section Control Module s needed using existing boom shutoff valves or Tru Count LiquiBlock valves Strip till liquid e Liquid Section Control of up to 48 sections or individual sections Field IQ Section Control Module s needed using Tru Count LiquiBlock valves e Liquid Rate Control using up to 2 Rawson drives connected to fixed displacement pumps such as CDS John Blue piston pumps to change liquid rate Field lIQ Rawson Control Module s needed e Liquid Rate Control using either a PWM or Servo control valve and flow meter Spreading e Spreading Rate Control using a Rawson Drive Field IQ Rawson Control Module s needed e Spreading Rate Control using either a PWM or Servo control valve and application rate sensor Air seeder e Section Control of up to 96 rows of blockage sensors e Section Control of up to 6 materials simultaneously with manual rate or prescription e Control existing PWM linear actuators or servo systems e Auxiliary sensors can read fan speed bin level air pressure and impleme
57. s On Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the On Latency value to compensate the delay and the system will turn on in advance Off Latency By default this is set to 0 0 seconds Use this setting unless you are experiencing a long response time from your clutch or valve this can happen on larger systems In this case increase the Off Latency value to compensate for the delay and the sytem will turn off after the set number of seconds Start Overlap Enter the distance of intentional swath overlap when entering a previously applied area The higher the number the greater the overlapped area End Overlap Enter the distance of intentional swath overlap when exiting a previously applied area The higher the number the greater the overlapped area Coverage Switching Overlap Enter the percentage of the section width for intentional swath overlap The higher the number the greater the overlapped area before the section is turned off Boundary Switching Overlap Enter the percentage of the section width for intentional overlap of a boundary The higher the number the greater the overlapped area into the boundary area FmX Integrated Display User Guide 237 10 The Field IQ Plugin Rate Control tab Adjust the rate control settings Field IQ Setup Setting
58. s controlling the sensor FmX Integrated Display User Guide 301 10 The Field IQ Plugin Operation tab Field IQ Setup o e on Control Cancel OK Rate Control Row Monitoring Sensors Operation Jump Start Speed 5 00 mph Shutoff Speed 0 36 mph Minimum Override Speed 0 00 mph When Outside Field Boundary wich Off Material Controlled By wich Boxes etna E boxes If you do not select Switch Boxes you will be unable to calibrate Rate Snapping 614i your material Setting Jump Start Speed This setting controls the speed to be used when the Field IQ master switchbox Master switch is put in the jump start position This manual override option can be used to operate the system when the vehicle is stationary Jump start is also used when GPS has become unavailable Shutoff Speed This setting controls when to shut the system down if the implement drops below the specified speed Minimum Override Speed This setting maintains the application rate when the implement s actual speed drops below the value entered It is used to ensure consistent material flow during slow speeds When Outside Field Boundary Switch off The system will not apply outside the boundary area Operate The system will apply outside the boundary area Material Controlled By Rate Snapping Enabled The material is tied to the Master Switch Box and cannot be controlled
59. s equipped with 3 way section valves that return flow to the tank when the boom section is off Pump Servo commonly used for anhydrous application Linear Actuator A valve that creates a linear motion as opposed to a rotary motion Electric over Hydraulic A valve that uses electric current to power the solenoid FmX Integrated Display User Guide 281 10 The Field IQ Plugin Feedback Setup tab Drive Setup Setting Description Flow Meter Type Select the type of flow meter that is connected Flowmeter Calibration Enter the number from the flow meter tag Min Flow Enter the required minimum flow rate for the system Use this setting to keep the control valve and flow meter above the minimum operating level 282 FmX Integrated Display User Guide The Field IQ Plugin 10 Row Monitoring tab Field IQ Setup Setting Description Row Monitoring Setup Disabled Row monitoring is turned off Blockage Select this option when using an air seeder or when applying granular material Seed Count Select this option for precision seeding Row Sensor Enable Turn individual row sensors on or off Row Sensor Wiring Select which wire each row sensor is wired to FmX Integrated Display User Guide 283 10 The Field IQ Plugin Sensors tab Add or edit sensor settings Field IQ Setup vac left Setting Description Add Sensor Add a new sensor
60. s the results and drive limits of your calibration 260 FmX Integrated Display User Guide The Field IQ Plugin 10 4 Select Flow Calibration and then tap OK The Flow Calibration screen appears In the Rate and Section Control Flow Calibration screen enter the Flow Meter type the Flow Meter Calibration and the Minimum Flow Rate and Section Control Flow Calibration Raven 6 Tap Run Calibration and then follow the on screen instructions Rate and Section Control Flow Calibration Test io A CAUTION Moving parts during this operation Ensure the implement is safe to operate FmX Integrated Display User Guide 261 10 The Field IQ Plugin Calibrating the implement lift switch 1 2 3 4 From the Field IQ Calibration screen select the Implement Lift option Raise the implement and then tap Next Lower the implement and then tap Next Tap OK to return to the Field IQ Calibration screen Operating in the field l 2 From the Home screen tap ef From the Current Configurations screen configure the display vehicle implement settings and then tap OK From the Field Selection screen select the required client farm field event settings and then tap OK Setting up the Field IQ system for Spraying Make sure that you have set your implement to Sprayer and that you have configured the implement see Configuring the display page 75 In the Material Overview screen tap New to open the Field IQ Se
61. s your target rate will apply e Bushel Weight Enter the bushel weight of the current material Tap Setup to set alarm thresholds and adjust the way seed statistics are calculated e High Alarm Triggers when the rate reaches the selected percentage above the target for longer than the delay setting e Low Alarm Triggers when the rate drops the below the target for longer than the delay setting for the selected percentage e Singulation Low Triggers when singulation reaches a percentage lower than 100 for longer than the delay setting e Seeds When Off Triggers when this percentage of seeds is detected while the sections are off for longer than the delay setting e No Seeds When On Triggers when this percentage of seeds is not detected for longer than the delay setting e Blockage Sensitivity Alarm When less than this amount of material is sensed for the number of seconds given e When no pulses are sensed for this amount of time the alarm triggers e Multiples Threshold If two seeds fall within this percentage of seed spacing it is considered a double Lowering this number requires seeds to be closer together to be reported as a double e Skips Threshold If two seeds fall outside of this percentage of seed spacing it is considered a skip Raising this number requires seeds to be further apart to be a skip e Averaging Sample Size This is the number of seeds used to calculate the average Increasing this amount makes the response
62. set in the Setup screen Override tab e 5b On position The sections and rate are ready to be commanded by the FmX integrated display e 5c Off position Sections are closed and rate is set to zero Note When you use Lock in Last Postion see page 272 the valve is locked and the rate is controlled by an auxiliary master valve or section X Tip Use the jump start function if you lose a GPS signal or you want to start applying before your implement is up to speed 226 Note All systems must have a Field IQ master switch box FmxX Integrated Display User Guide The Field IQ Plugin 10 Field IQ 12 section switch box optional Only one section switch box can be used on each system Each section switch is automatically assigned to the corresponding section The sections are read from left to right For example switch 1 assigns to the section furthest on the left when standing behind the implement For more information see the Hardware tab in Setup screen of the Field IQ plugin The section switches have different functions depending upon the status of the master Automatic Manual section control switch on the master switch box When the Automatic Manual section control switch is in the Automatic position e Ifthe section switch is in the on up position the section s assigned to it are commanded automatically by the FmX integrated display e Ifthe section switch is in the off down position
63. settings Field IQ Setup vac left Setting Description Add Sensor Add a new sensor Edit Sensor Edit or view the settings for an existing sensor Remove Sensor Delete an existing sensor When adding or editing a sensor enter the following information Setting Description Sensor Type Select from e Air pressure vacuum e Liquid pressure e NH3 pressure e Bin level e RPM e Gate Height Name Use the virtual keyboard to enter a name for the sensor Sensor Setup Field IQ module Select the Field IQ module that is controlling this sensor Input location Specify which wire is controlling the sensor 258 FmX Integrated Display User Guide The Field IQ Plugin 10 Operation tab Field IQ Setup oe on Control Cancel OK Rate Control Row Monitoring Sensors Operation Jump Start Speed 5 00 mph Shutoff Speed 0 36 mph Minimum Override Speed 0 00 mph When Outside Field Boundary wich Off Material Controlled By wich Boxes etna E boxes If you do not select Switch Boxes you will be unable to calibrate Rate Snapping 614i your material Setting Jump Start Speed This setting controls the speed to be used when the Field IQ master switchbox Master switch is put in the jump start position This manual override option can be used to operate the system when the vehicle is stationary Jump start is also used when GPS h
64. slower but more stable e Misplaced Seeds Threshold If a seed falls outside this percentage of seed spacing then it s considered misplaced and reduces the spacing quality Layout tab 234 FmxX Integrated Display User Guide The Field IQ Plugin 10 Enter information about the implement that will be used to apply the material Cancel Material Layout Row Monitor 4 gt Section Control Rate Control Bin Tank Setup Row Offset Setup a Setting Description Bin Tank Setup Allows the system to track how much material is left in the bin tank and provides a warning when the bin tank needs to be refilled Adjust the settings for Status On The system will track the bin tank level and provide warnings Off The system will not track the bin tank level or provide warnings Capacity Units Select Default Units or Bushels Default units will vary according to the type of material that is being applied Bin Capacity The amount the tank bin holds when full Note Markings on tank bin may not be accurate Current Volume Current volume of the product in the tank Partial Refill The amount of material that will be added to the bin tank during a partial refill Warning Level A warning will appear on your screen when your bin tank reaches a set threshold Refill Tank Bin Refills the tank bin to capacity Partial Refill Tank Bin Refills the tank bin to the amount spec
65. system to track how much material is left in the bin tank and provides a warning when the bin tank needs to be refilled Adjust the settings for Status On The system will track the bin tank level and provide warnings Off The system will not track the bin tank level or provide warnings Capacity Units Select Default Units or Bushels Default units will vary according to the type of material that is being applied Bin Capacity The amount the tank bin holds when full Note Markings on tank bin may not be accurate Current Volume Current volume of the product in the tank Partial Refill The amount of material that will be added to the bin tank during a partial refill Warning Level A warning will appear on your screen when your bin tank reaches a set threshold Refill Tank Bin Refills the tank bin to capacity Partial Refill Tank Bin Refills the tank bin to the amount specified in the Partial Refill field FmX Integrated Display User Guide 295 10 The Field IQ Plugin Setting Description Row Offset Setup Row Offset Setup provides additional tuning by detailing where the material will be applied in relation to the vehicle Increase coverage accuracy by selecting one or two offsets Row offsets are measured from the Application Offset that is entered in the Measurements tab of the Implement Configuration wizard See Implement Configuration Measurements page 165 e Number of row offsets Use 1
66. t how far off target the rows ar applying Green Rows are applying on target Red Rows are applying off target Black Rows have been manually turned off White Rows have been turned off automatically by the system Tap the arrows to view more row numbers Tap to return to the previous plugin screen Linking Materials 230 The Field IQ system can link primary and secondary materials where the secondary material uses the output of the primary material For example LiquiBlock valves can be linked to use the output of Tru Count Air Clutch systems When planting seeding or strip tilling you can link the following together e Liquid e Granular seed e Granular fertilizer Anhydrous cannot be linked When the system is in diagnostics mode the secondary material is not functional When the system is in diagnostics mode you can only operate a linked material when you also open the sections of the primary material FmxX Integrated Display User Guide l 2 3 The Field IQ Plugin 10 In the Section Control tab in the Section Control field select Link to Material Field IQ Setup Link to Material In the Linked Material field select the primary material that you want to link to Select the Rate Control tab and then set that up as usual For more information see the sections below General setup information Do the following prior to setting up the Field IQ system for planting spraying
67. tem Use this setting to keep the control valve and flow meter above the minimum operating level 240 FmX Integrated Display User Guide The Field IQ Plugin 10 Row Monitoring tab Field IQ Setup Setting Description Row Monitoring Disabled Row monitoring is turned off Blockage Select this option when using an air seeder or when applying granular material Seed Count Select this option for precision seeding Setup Row Sensor Enable Turn individual row sensors on or off Row Sensor Wiring Select which wire each row sensor is wired to FmX Integrated Display User Guide 241 10 The Field IQ Plugin Sensors tab Add or edit sensor settings Field IQ Setup vac left Setting Description Add Sensor Add a new sensor Edit Sensor Edit or view the settings for an existing sensor Remove Sensor Delete an existing sensor When adding or editing a sensor enter the following information Setting Description Sensor Type Select from e Air pressure vacuum e Liquid pressure e NH3 pressure e Bin level e RPM e Gate Height Name Use the virtual keyboard to enter a name for the sensor Sensor Setup Field IQ module Select the Field IQ module that is controlling this sensor Input location Specify which wire is controlling the sensor 242 FmX Integrated Display User Guide The Field IQ Plugin 10 Operation tab Field IQ Setup oe
68. tions e Tru Count Air Clutch Installation Instructions e Rawson Installation Instructions For the latest versions of these documents go to www trimble com agriculture Note When using Rawson drives and when using more than one material you must have a separate Section Control Module SCM for materials using Rawson drives FmX Integrated Display User Guide 225 10 The Field IQ Plugin Field IQ master switch box functions Feature Function Increment decrement switch Increases the applied amount by a set amount the amount is set in the Setup screen Rate tab Rate switch Choose to use preset Rate 1 preset Rate 2 or Manual rate LED indicator Red Unit is powered but not communicating with the FmX integrated display Green Unit is powered and communicating with the FmX integrated display Yellow Unit is initializing communications with the FmX integrated display Automatic Manual section switch Automatic mode The FmX integrated display automatically opens and closes sections when entering areas of overlap non apply zones or crossing boundaries Manual mode The sections are controlled by the user using the Field IQ system x Tip You can switch from Automatic to Manual mode while traveling Master switch e 5a Jump start position The same functions as in Master On are active plus the system is overridden to use a preset control speed the speed is
69. tup Wizard The Wizard contains the following seven tabs For information on this tab See Material page 233 Layout page 234 Section Control page 236 Rate Control page 238 Row Monitoring page 241 Sensors page 242 Operation page 243 262 FmxX Integrated Display User Guide The Field IQ Plugin 10 Material tab Enter information about the material you want to set up Field IQ Setup B way Material Cancel OK Layout Section Control Rate Control Sensors 4 gt Material Type bo Liquid gt Material Name 20340 Application Rate Setup Setting Description Material Type Material Name Select your Field IQ application type Note If spraying chemicals use the liquid fertilizer setting e Row Crop Seed e Liquid e Granular Seed e Granular Fertilizer e Anhydrous Use the virtual keyboard to enter a name for the material Application Rate Rates tab Adjust the following Rate settings e Target Rate This setting controls the volume that the implement supplies when the Rate switch is in position 1 e Target Rate 2 This setting controls the volume that the implement supplies when the Rate switch is in position 2 e Rate Increment When the Rate switch is in the Rate 1 or Rate 2 position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your mast
70. w Crop Seed e Liquid e Granular Seed e Granular Fertilizer e Anhydrous Material Name Use the virtual keyboard to enter a name for the material Material Details Tap Setup to open the Hybrid Setup screen See Logging varieties page 65 FmxX Integrated Display User Guide 233 10 The Field IQ Plugin Setting Description Application Rate Rates tab Adjust the following Rate settings e Target Rate This setting controls the volume that the implement supplies when the Rate switch is in position 1 e Target Rate 2 This setting controls the volume that the implement supplies when the Rate switch is in position 2 e Rate Increment When the Rate switch is in the Rate 1 or Rate 2 position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Manual Rate Increment When the Rate switch is in the Manual position the current application rate increases or decreases by this amount each time you press the Rate adjustment increment decrement switch on your master switch box e Minimum Rate This setting is the minimum rate that will be applied e Maximum Rate This setting is the maximum rate that will be applied Rate Alarms Units tab Adjust the following Unit settings e Seeds Per Pound Enter the number of seeds per pound of the current material e Target Rate Units Choose what unit
71. will track the bin tank level and provide warnings Off The system will not track the bin tank level or provide warnings Capacity Units Select Default Units or Bushels Default units will vary according to the type of material that is being applied Bin Capacity The amount the tank bin holds when full Note Markings on tank bin may not be accurate Current Volume Current volume of the product in the tank Partial Refill The amount of material that will be added to the bin tank during a partial refill Warning Level A warning will appear on your screen when your bin tank reaches a set threshold Refill Tank Bin Refills the tank bin to capacity Partial Refill Tank Bin Refills the tank bin to the amount specified in the Partial Refill field FmX Integrated Display User Guide 251 10 The Field IQ Plugin Setting Description Row Offset Setup Row Offset Setup provides additional tuning by detailing where the material will be applied in relation to the vehicle Increase coverage accuracy by selecting one or two offsets Row offsets are measured from the Application Offset that is entered in the Measurements tab of the Implement Configuration wizard See Implement Configuration Measurements page 165 e Number of row offsets Use 1 row offset when coverage is applied at a single location Use two row offsets when planting singulated seed with staggered implements e Row Offset 1 row offset Enter t
72. with the module 306 FmX Integrated Display User Guide