1. UV Lamp 10 Please be sure to read the following Cleaning External Surfaces 10 instructions carefully to ensure optimal Replacing the UV Lamp 11 performance and safety TROUBLE SHOOTING 12 www envionproducts com Thetapwieegy Envion Ud ONE YEAR LIMITED WARRANTY 13 P O Box 9159 ays a ARBITRATION AGREEMENT 14 800 875 8577 y ENVION 2 3 SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS WARNING RISK OF ELECTRICAL SHOCK Safety precautions should always be used when operating this or any electrical appliance Decrease the risk of electrocution electric shock injury or fire by reading and following all the warnings below Use only as described in this Therapure manual To reduce the risk of electric shock do not attempt to service the product in any way other than in the manner described in the Cleaning amp Maintenance section of this manual READ ALL INSTRUCTIONS BEFORE OPERATING THE AIR PURIFIER This product operates at 120V AC 60Hz only Do not run cord under carpeting Do not cover cord with throw rugs runners or similar coverings Arrange cord away from traffic area and where it will not be tripped over _ Do not operate the product in any greasy environment such as in the kitchen This product is not intended to filter oil or grease from the air Do not use the Therapure 230 air purifier in bathrooms or other humid environments Do not use near fireplaces or in areas where flammable or c
2. power outlet by holding onto the plug itself and pulling gently gt _ Never pull on the cord itself to unplug it from its power outlet gt _ Use care when operating the Therapure 230 air purifier by keeping all foreign objects fingers body parts hair loose clothing and jewelry away from openings gt Never touch the Therapure9 230 air purifier or its plug when your hands are wet The Therapure 230 air purifier is an electrical appliance Adult supervision is required when operating the Therapure 230 in the presence of children To reduce the risk of fire or electric shock do not use this air purifier with any solid state speed control devices IMPORTANT WARNINGS UV Lamp Notice UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision Never look directly at the UV lamp while it is illuminated doing so could cause loss of vision Only view illumination through the window at the front of the unit To prevent exposure to ultraviolet light disconnect the power to the unit before servicing any part of the Therapure 230 air purifier UV Lamp Disposal If the UV lamp breaks turn off the unit Do not operate the unit with a broken lamp Do not use a vacuum to clean up breakage Sweep debris into a plastic bag and dispose of properly Contact your local waste management authority for instructions regarding recycling and the proper disposal of old lamp s To order a replacement l
3. that no class or representative actions of any type are permitted 3 ARBITRATION PROCEDURES a Before instituting an arbitration if you have any dispute we strongly encourage you to contact the Company to try to resolve the matter by calling 800 218 3560 although you are not required to do so UT b The arbitration of any claim or dispute under this Agreement shall be conducted in accordance with the expedited procedures set forth by ENVION in the JAMS Comprehensive Arbitration Rules and Procedures as those Rules exist on the date you receive the Product including Rules 16 1 and 16 2 of those Rules These rules and procedures are available by calling JAMS or by visiting its web site at www jamsadr com The arbitration of any claim or dispute under this Agreement shall be conducted by an arbitrator who has at least five years of experi ence conducting arbitrations c The arbitration of any claim or dispute under this Agreement shall be conducted in the State of California or the location in which you received this Agreement For claims of 10 000 or less you may choose whether the arbitration proceeds in person by telephone or based only on submissions d The Company shall pay costs for the arbitration of claims including any JAMS Case Management Fee and all professional fees for the arbitrator s services The Company shall pay the fees and costs of its own counsel experts and witnesses and shall not be able to recoup them from you even if yo
4. toxic fumes such as paint and new carpet fumes gt Effectively removes smoke pollen dust animal dander dust mites mold and bacteria gt gt 3 speed fan setting lets you select the desired cleaning level Ht Locking Latch 1 Locking Latc 5 Control Panel 6 Control Dial W 2 Air Inlet Grill 3 Permanent HEPA Type Filter al 7 UV VOC Button A varare J 8 Air Outlet Grill TT L UU UUL hd MIND NC LC F DN m E 4 UV Lamp Cover 10 UV Lamp 9 Base of Unit 230 7 OPERATING THE THERAPURE 230 OPERATING THE THERAPURE 230 Before using the Therapure 230 air purifier please read Safety the following important information 1 Do not place near fans Electrical Ratings 2 Keep both sides of the unit at least 1 foot away from a wall 120V Setting 120Vac 60 Hz 3 Do not place the unit near curtains Power consumption 55 watts 0 5 ampere at high 4 Placing the unit close to the source of air pollution is an effective way to improve fan speed f indoor air quality 3 watt UV light lamp Net weight 10 3 lbs Dimension LxWxH 9 6 x 7 9 x 26 1 i ff YL GWM 7 Replacement Parts Lamp TPP2400 Filter TPP240F i TIN NN Cd Locate a level surface on which to pl
5. ITRATION AND NOT IN COURT IT ALSO PROVIDES THAT ANY DISPUTE CANNOT BE RESOLVED IN A CLASS ACTION OR OTHER PROCEEDING WHERE YOU REPRESENT OTHER PERSONS OR OTHER PERSONS REPRESENT YOU AND THAT NO CLASS OR REPRESENTATIVE ARBITRATIONS ARE PERMITTED PLEASE CAREFULLY READ ALL TERMS IN THIS AGREEMENT 1 RESOLUTION OF CLAIMS OR DISPUTES Any claim or dispute between you and Company or any of Company s subsidiaries or affiliates arising out of or relating in any way to the Product or this Agreement shall be resolved through final binding arbitration This arbitration obligation is reciprocally binding on both you and the Company and applies regardless of whether the claim or dispute involves a tort fraud misrepresentation product liability negligence violation of a statute or any other legal theory Both you and Company specifically acknowledge and agree that you waive your right to bring a lawsuit based on such claims or disputes and to have such lawsuit resolved by a judge or jury 2 LIMITATION OF LEGAL REMEDIES All arbitrations under this Agreement shall be conducted on an individual and not a class wide basis and an arbitrator shall have no authority to award class wide relief You acknowledge and agree that this Agreement specifically prohibits you and the Company from commencing arbitration proceedings as a representative of others or joining in any arbitration proceedings brought by any other e U re person The parties agree
6. ace the Therapure 230 air purifier near a 120V outlet follow warnings in the SAFETY INSTRUCTIONS and IMPORTANT WARNINGS sections of this manual Position your Therapure at least one foot 12 inches from the wall Plug in the unit ARAL l A my U ONID www envionproducts com to order for a replacement filter Or call1 800 875 8577 Z SSS l TO O WSS NS 3 4 WSS WSS Note WS DO NOT run the Therapure 230 with a broken filter Replace the filter if the filter has a tear NSS hole in it WSS or a hole in it N If the filter is damaged or needs replacement please visit the Therapure website at Ss OPERATING THE THERAPURE 230 CONTROLS SETTINGS Power Control To operate the Therapure 230 air purifier turn the knob clockwise to turn on Speed Control The Therapure 230 has three different speeds of cleaning LOW MED and HI Turn the knob ONCE for LOW TWICE for MED and THIRD for HI UV Control Press the UV VOC control button UV VOC to turn on the UV lamp to kill harmful airborne germs and reduce harmful VOC volatile organic compounds Press it again to turn off the UV and VOC A blue UV indicator light will light up around the button when UV VOC is turned on UV VOC Button UV Indicator Light Control Dial g CLEANING amp MAINTENANCE Keep the Therapure 230 func
7. amp call 1 800 875 8577 or go to www envionproducts com Mercury Notice Because the Therapure 230 contains a light bulb and light bulbs contain mercury Envion is required to provide the following warning WARNING This product contains mercury a chemical known to the State of California to cause birth defects or other reproductive harm Do not place your used lamp s in the trash Disposal of any item containing mercury must be in accordance with any hazardous waste disposal or recycling laws and regulations of your state TED2ZO 230 4 5 PRODUCT GENEFITS MAIN PARTS CZ gt gt Quadruple action purification 1 Permanent HEPA Type Filter takes particles out of the air purifying it 2 UV lamp reduces germs such as viruses and bacteria Locking Latch 2 Air Inlet Grill 3 Permanent HEPA Type Filter the permanent filter removes small visible and non visible particles down to 0 1 microns in size 4 UV Lamp Cover 5 Control Panel 6 Control Dial there are 3 speed settings low medium and high for you to choose from according to the air quality needs in the room 7 UV VOC Button the germicidal UV VOC light is used to kill harmful airborne bacteria germs and viruses and reduce harmful VOC volatile organic compounds 8 Air Outlet Grill 9 Base of Unit 10 UV Lamp hi y I i i 3 Photo catalyst filter helps remove VOCs volatile organic compounds from the air including
8. ombustible vapors or products may exist gt _ Always unplug the power cord from the electrical outlet when the purifier is not in use before cleaning inserting or removing parts or before moving to another location Never run the air purifier unless it is fully assembled gt _ This appliance has a polarized plug one blade is wider than the other To reduce the risk of electric shock this plug is intended to fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Do not attempt to defeat this safety feature Always turn off all controls before unplugging the Therapure 230 air purifier from the outlet Attempting to service the Therapure 230 air purifier in any way that is not described in this owner s manual will cause the warranty to be voided and could cause serious personal injury to the user and or result in considerable damage to the unit _ Do not place the cord near a heated surface gt _ Do not operate this product with a damaged cord or plug Discard the product or return to an authorized service facility for examination and or repair gt _ Never use the power cord to pick up carry drag pull or lift the Therapure 230 air purifier Do not pull the cord against or around sharp corners and edges This could result in injury to the user or damage to the cord _ Always remove the plug from its
9. or any possible damage replace the filter back in the reverse direction described here Exposing the Therapure 230 to candle oil fireplace soot and smoke is not recommended and will reguire more freguent cleaning 230 10 CLEANING amp MAINTENANCE Cleaning External Surfaces 1 Turn off and unplug unit 2 Usea washcloth slightly dampened with a little water and dishwashing soap to wipe the outer case surfaces 3 Donot allow water to slip into the internal parts as this could damage your unit and result in electrical shock and injury to you 4 Allow the unit to thoroughly dry before use UV Lamp The lifetime of the UV lamp is up to 12 months of continuous effective operation After this time the bulb may remain illuminated but its effectiveness is greatly reduced For maximum germicidal protection please replace the UV bulb annually If the lamp stops functioning or needs replacement please visit our web site at www envionproducts com to order a replacement lamp Or call 1 800 875 8577 Caution e Do not touch the glass part of the lamp Oil from fingertips will decrease the effectiveness of the lamp e Never operate the unit without a filter or with a damaged filter UV lamp cover must be installed at all times The UV light from the UV lamp will result in severe damage to eyes and could cause blindness UV Lamp Notice Warning UV Ligh
10. t is harmful to bare skin and eyes and can cause temporary or permanent loss of vision Never look directly at the UV lamp while it is illuminated doing so could cause loss of vision SS SSS TEE2BO 11 CLEANING amp MAINTENANCE Before replacing the UV lamp make sure the Therapure air purifier is turned off and unplugged Let the lamp cool down for 5 minutes before replacing it Replacing the UV Lamp 1 Release the inlet grill by pressing on the locking latch see diagram of Main Parts 2 Remove the two bolts used to fix the UV lamp cover and remove the cover out from the unit 3 Unscrew the old UV lamp from the lamp base of the unit 4 Install the new UV lamp into the lamp base of the unit 5 Install the UV lamp cover with the two bolts on the unit 6 Install the inlet grill on the unit l 2 3 230 12 13 TROUGLESHOOTING PROBLEM Unit will not operate Reduced airflow or poor filtering No visible light in the UV light view window REASON Power button has not been turned on Unit is unplugged The inlet grill has not been installed amp locked into place The inlet or outlet grill may be blocked Permanent filter may be clogged UV button is not turned on UV lamp is broken SOLUTION Press the Power button Check to ensure
11. tioning properly by cleaning the permanent HEPA Type Filter every four weeks More frequent cleaning will be necessary if the unit is located in an area with a high level of airborne contaminants excessive amounts of smoke pet dander etc NOTE Always make sure the Therapure 230 is turned off and unplugged before cleaning gt gt Vacuuming will restore performance of the permanent HEPA Type Filter However the filter may appear stained This is normal and does not affect performance in any way gt gt Do not use water or any household cleaners or detergents to clean the permanent HEPA Type Filter gt gt The inlet grill may be cleaned after unit is turned off and unplugged with a vacuum or a slightly damp cloth Cleaning the permanent HEPA Type Filter 1 Release the inlet grill by pressing on the locking latch see diagram of Main Parts 2 Remove the inlet grill from the unit as shown below 3 Grasp the left and right frames of the permanent HEPA Type Filter through the indentations on the sides of the filter enclosure and remove the filter 4 To clean the permanent HEPA Type Filter use the brush or crevice attachment with a vacuum cleaner Run the attachment along the inlet and outlet sides of the filter cleaning between the crevices as much as possible Do not use water or any household cleaners or detergents to clean the permanent HEPA Type Filter 5 Once the permanent HEPA Type Filter has been cleaned and checked f
12. u do not prevail in the arbitration Unless otherwise provided by law you acknowledge and agree that you shall pay the fees and costs of your own counsel experts and witnesses 4 CHOICE OF LAW The arbitration provisions of this Agreement and any arbitration conducted pursuant to the terms of this Agreement shall be governed by the Federal Arbitration Act 9 U S C Secs 1 16 In this respect the parties acknowledge that this Agreement involves a transaction conducted in interstate commerce Otherwise this Agreement and the rights of the parties hereunder shall be governed by and construed in accordance with the laws of the State of California exclusive of conflict or choice of law rules 5 SEVERABILITY If any provision of this Agreement is declared or found to be unlawful unenforceable or void such provision will be ineffective only to the extent that it is found unlawful unenforceable or void and the remainder of the provision and all other provisions shall remain fully enforceable 230 Re
13. unit is plugged in Check to make sure filter is properly installed amp locked into place Check to ensure nothing is blocking air inlet amp air outlet Check amp clean filter if necessary Check that the UV button is turned on Replace the UV lamp ONE YEAR LIMITED WARRANTY ONE YEAR LIMITED WARRANTY Your Therapure 230 air purifier is warranted to be free from defects in materials and workmanship for one year from the original purchase date Should the product have a defect in materials or workmanship we will repair or replace it without charge to you a shipping and processing fee will apply To obtain service under warranty simply call our customer service center toll free at 800 875 8577 This warranty does not cover damage caused by accident misuse or any use other than as intended and described in this product manual or damage resulting from failure to maintain and clean this product as specified in this product manual This warranty applies only to the original purchaser of the Therapure 230 air purifier ALL EXPRESS AND IMPLIED WARRANTIES FOR THIS PRODUCT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE WARRANTY PERIOD AND NO WARRANTIES WHETHER EXPRESS OR IMPLIED WILL APPLY AFTER THIS PERIOD Some states do not allow limitations on the duration of implied warranties so the above limitation may not apply to you While this warrant
14. w 3 Ge M Me D o RRHRBBRBBRBRBBBRBRWB EA HR EA EA EA EA EA EA RR RR A SL WR RIF YDD29 0 therapure uv germicidal air purifier y MM TI thera pure Se l ih uv germicidal air purifier E E E E SS Gy SS LSS LSS LS E E E LZ e LS S ENVION ENVION by by TAGLE OF CONTENTS SAFETY INSTRUCTIONS 2 Thank you for purchasing the Therapure MO g IMPORTANT WARNINGS 3 230 air purifier With UV germicidal i UV Lamp Notice 3 protection to reduce germs and Mercury iotice 3 permanent HEPA type filtration to purify UV Lamp Disposal Notice 3 the air the Therapure 230 air purifier UV Lamp Breakage 3 will greatly improve the guality of the air in your home office or other PRODUCT BENEFITS 4 environments We want you to be fully satisfied with your Therapure 230 MAIN PARTS 5 That s why your Therapure 230 comes WE DI OPERATING THE THERAPURE 230 AIR PURIFIER 6 Getting Ready 6 Once you ve experienced the purity of Ope ration 3 Therapure 230 air visit us at our website Controls Settings g to find out more ways to improve the quality of your air and your life with our CLEANING amp MAINTENANCE 9 premium products and upgrades Cleaning the Permanent Filter 9 Maintenance
15. y gives you specific legal rights you may also have other rights which may vary from state to state Contact Info for Warranty Service Therapure by Envion LLC P O Box 9159 Van Nuys CA 91409 8291 1 800 875 8577 www envionproducts com 2013 Envion LLC All Rights Reserved Patents pending The energy efficiency of this ENERGY STAR qualified model is measured based on a ratio between the model s CADR for dust and the electrical energy it consumes or CADR Watt This product earned the ENERGY STAR by meeting strict energy efficiency guidelines set by the US EPA US EPA does not endorse any manufacturer claims of healthier indoor air from the use of this product thera pure uv germicidal air purifier TEP2BO y ENVION 230 14 15 ARBITRATION AGREEMENT PLEASE READ THIS AGREEMENT CAREFULLY YOU ACCEPT THE TERMS OF THIS AGREEMENT BY RETAINING THE PRODUCT S SHIPPED IN CONNECTION WITH THIS AGREEMENT THE PRODUCTS FOR MORE THAN THIRTY 30 DAYS AFTER RECEIPT IF YOU DO NOT AGREE TO THE TERMS OF THIS AGREEMENT YOU MAY RETURN THE PRODUCT TO COMPANY WITHIN THIRTY 30 DAYS OF RECEIPT FOR A FULL REFUND THIS ARBITRATION AGREEMENT AGREEMENT CONTAINS A MANDATORY ARBITRATION PROVISION THAT AFFECTS YOUR LEGAL RIGHTS AND REMEDIES BY PROVIDING THAT DISPUTES BETWEEN YOU AND THE MANUFACTURER DISTRIBUTOR AND OR SELLER OF THIS PRODUCT COLLECTIVELY COMPANY MUST BE RESOLVED THROUGH BINDING ARB

Download Pdf Manuals

image

Related Search

Related Contents

Quickbooks User Guide  Philips FW830C/37 User's Manual  Wizard Extreme  User Manual EN Gebrauchsanweisung DE  MANUAL FOR BLUETOOTH SPEAKER  E. LA TENSION ARTERIELLE  iHome IBN20  Samsung MM-J4 User Manual  Dites-nous vos rêves et vos colères  

Copyright © All rights reserved.
Failed to retrieve file