1. FA UL O Br iA or RUN RUN _ pos u The valid value range is between 1 and 126 2MBD A new address value is only accepted upon device power up XX XX XX XX 7008A003 Figure 8 Diagnostic and status indicators of the FLM BK PB M12 DI 8 M12 7008_en_01 PHOENIX CONTACT 5 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI8 M12 Communications power Communications power present Communications power too low Red LED No cyclic data transmission PROFIBUS not connected master not active Incorrect settings configuration via master station address Timeout expired LED OFF Device addressed by PROFIBUS a parameterization was received No power supply for the device In this state the UL LED also is off because of the missing 24 V communications power Device status LED green red yellow Device ready to operate Green flashing A recoverable error is present local bus not complete ine Station in process data mode Green red Device in selftest state Flashing flicker Red ON An irrecoverable error is present Local bus is read no process data transmission on local bus 1 Hz Yellow flashing More than 64 devices configured or system restriction of 244 bytes of process 1 Hz data configuration data exceeded OFF Voltage not present LED Status of local bus communication green red Local bus is running data cycles I O error present 1 H
2. 0 5235 3 00 Fax 49 0 5235 3 4 12 00 www phoenixcontact com www phoenixcontact com salesnetwork onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 Pin Assignment TS FE Functional earth ground 0 BUSIN PROFIBUS IN BUS IN Te BF RUN O OUT BUS OUT PROFIBUS OUT LB OUT Local bus OUT FLM local bus FE x10 a Uis IN Power supply IN x nde LORN ts OUT logic and sensor supply O Omen Ts U_s OUT Voltage supply OUT logic and sensor a supply for additional devices INT IN2 iNT toINB inputs 7 to 8 O O IN3 IN4 Gaj In general the maximum current load of 4 A per contact must not be exceeded s IN5 IN6 O O I5 16 E OHL nz ins IN O 0 oe MEG O O PHGNIX BK PB O egatacr 7008A002 Figure 2 Connections of the FLM BK PB M12 DI 8 M12 7008 _en_01 PHOENIX CONTACT 2 Pin Assignment PROFIBUS BUS IN BUS OUT LB OUT Qa PROFIBUS pin assignment M12 B encoded 6625B004 Figure 3 Pin BUSIN susor i ie e OO ie sano RxD TxD P B RxD TxD P Le Shield Shield onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 Local Bus Pin Assignment LB OUT LB OUT es Local bus pin assignment LB OUT 7008A005 Figure 4 Pn wor O PNI 2 w IEY The shield is conne
3. Hz 1 min Digital inputs sensor supply I O FE 500 V AC 50 Hz 1 min Digital inputs Sensor supply I O 500 V AC 50 Hz 1 min incoming remote bus Incoming remote bus FE 500 V AC 50 Hz 1 min 7008 _en_01 PHOENIX CONTACT 12 Ordering Data Ordering Data Device and Accessories Description Fieldline Modular Bus Coupler for PROFIBUS With 8 Digital Inputs Protective caps for unused sockets Protective caps for unused male connectors 5 pos shielded metal socket B encoded for the incoming local bus Shielded metal connector 5 pos B encoded for the outgoing remote bus and local bus Markers Bridging cable for power supply A encoded 5 pos unshielded Bridging cable for the local bus B encoded 5 pos shielded Assembly system for 5 devices Assembly system for 7 devices Order Designation FLM BK PB M12 DI 8 M12 IBS IP PROT IO PROT M12 M SACC M12FSB 5SC SH SACC M12MSB 5SC SH ZBF 12 UNBEDRUCKT SAC 5P MS 0 13 186 FS SCO SAC 5P MSB 0 13 PUR FSB SCO SH FLM MP 5 FLM MP 7 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 Order No 27 36 330 2 59919 27 36 19 4 15 13 59 6 15 13 57 0 08 09 735 15 18 48 1 15 18 47 8 27 36 66 0 2 7 36 67 3 Pcs Pkt J IEY Additional accessories for connecting the sensors and actuators can be found in the Phoenix Contact PLUSCON catalog Ordering Data for Documentation Description Installing the Fieldli
4. LINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 Error Messages to the Higher Level Control or Computer System Sensor supply short circuit Yes Sensor supply overload Yes IEY If an error is triggered by an overload or short circuit of the sensor supply the device switches off the sensor supply of the channels and updates the diagnostics The corresponding error message can then be read out by the master If the sensor supply Us is not sufficiently high the master can read out an appropriate error message also Interface Bus system PROFIBUS DP Incoming Bus Coupling of shield connection Directly to FE Transmission Speed 12 Mbaud maximum Outgoing Bus Coupling of shield connection Directly to FE Transmission Speed 12 Mbaud maximum For transmission rates of more than 3 MBaud in PROFIBUS series inductance is available in the device Please observe the installation instructions of the PROFIBUS User Organization Electrical Isolation Isolation of the Voltage Areas For device connection please note the instructions and regulations in the Installing the Fieldline Product Range user manual FLS FLM SYS INST UM E Order No 26 98 97 3 Separate Potentials in the FLM BK PB M12 DI 8 M12 Test Distance Test Voltage 24 V supply bus logic FE 500 V AC 50 Hz 1 min 24 V supply bus logic digital inputs 500 V AC 50 Hz 1 min sensor supply I O 24 V supply bus logic incoming remote bus 500 V AC 50
5. P65 IP67 protection cover unused sockets with protective caps Avoid damage to the electronics Make sure you only supply the sensors with the voltage Us provided at the connection points Avoid polarity reversal Avoid polarity reversal of the supply voltages U and Us in order to prevent damage to the device Observe connection point assignment gt PBB D When connecting the sensors observe the assignment of the connection points to the PROFIBUS IN process data see Process Data on page 9 7008 _en_01 PHOENIX CONTACT 8 THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI8 M12 Configuration Data Input address area Process Data Assignment of the Connection Points to the IN Process Data Byte bit view Byte 0 ooo o et 7 e s 4 sa e2 i 0 r s a s 2 Diagnostic Data Mapping of the Diagnostic Data in PROFIBUS Diagnostic Bit 7 Data x Byte0 Byte0 OX Station status 1 status 1 OX e o SSCS Sate ss n OX x Byte2 Byte2 n Station status3 status 3 Byte 3 Saton sauss _ address gag nostics Byte 4 1 1 Fgh 10 number E w et ee a a e Bytes 0 to 5 are PROFIBUS standard Bytes 6 to 78 are device specific For information on device specific bytes please refer to the FLS FLM PB SYS PRO UM E user manual Order No 26 99 07 9 lf a diagnostic event occurs the diagnostic data is always sent to the master by means of a diagnostic telegram generated once by the d
6. THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS 9G O0GD00C gt D conn OCD OOE INSPIRING INNOVATIONS FLM BK PB M12 DI 8 M12 Fieldline Modular Bus Coupler for PROFIBUS With 8 Digital Inputs AUTOMATIONWORX Data Sheet PHOENIX CONTACT 05 2005 Description Channel specific diagnostics for different I O devices ee Dynamic configuration and empty spaces The device connects a Fieldline modular station to PROFIBUS DP and is also used to acquire digital signals Features Connection to PROFIBUS DP using M12 connectors B encoded Opens the Fieldline modular local bus using M12 connectors B encoded Connection of digital sensors using M12 connectors Flexible voltage supply concept LED diagnostic and status indicators for bus operation and voltage supply Short circuit and overload protection of the sensor supply P65 IP67 protection 7008A001 Figure 1 FLM BK PB M12 DI 8 M12 This data sheet is only valid in association with the FLS FLM SYS INST UM E Order No 26 98 97 3 and FLS FLM PB SYS PRO UM E Order No 26 99 07 9 user manuals Make sure you always use the latest documentation It can be downloaded at www download phoenixcontact com A conversion table is available on the Internet at www download phoenixcontact com general 7000 en 00 pdf 7008 en 01 PHOENIX CONTACT GmbH amp Co KG FlachsmarktstraBe 8 32825 Blomberg Germany 1 Phone 49
7. cted to FE in the device The thread is used for shielding 7008 _en_01 PHOENIX CONTACT 3 Pin Assignment of the Voltage Supply ULs O IN OUT AD Fy d Pin assignment of the voltage supply ULs 6954A003 OUT mm ON or You can change the transmission speed on the local bus from 500 kBaud to 2 MBaud The transmission speed is switched to 2 Mbaud by jumpering 24 V U Pin 1 to Pin 5 Voltages U and Us at female connector U gt OUT can each only carry a maximum current of 2A gt amp 7008 _en_01 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 Pin Assignment of the Inputs E A Pin assignment of the inputs 6625A006 Figure 6 Input Socket INx INx 1 Us 24 V Input x 1 GND Input x Assignment of the Input Sockets 6954B005 Figure 7 IRTP Two input signals can be connected to each input socket Assignment of the input sockets PHOENIX CONTACT 4 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 Local Diagnostic and Status Indicators Rotary Encoding Switches Set the station address using both rotary encoding switches X10 for the first digit of a two digit number and X1 for the MD second digit of a two digit number The PROFIBUS master addresses the device by means of this station address UL
8. ction 30g load half sinusoidal wave positive and negative in each space direction IRTP For additional information on mechanical requirements and ambient conditions please contact Phoenix Contact 7008 _en_01 PHOENIX CONTACT 10 Voltage Supply Nominal value Range Current consumption at U at 24 V DC At 500 kbaud At 2 Mbaud Current consumption at Us at 24 V DC THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 24 V DC 18 V DC to 30 V DC ripple included 75 mA typical 100 mA maximum 75 mA typical 100 mA maximum 15 mA sensor current typical 600 mA maximum is Voltages U and Us at female connector U s OUT can each only carry a maximum current of 2 A Digital Inputs Number Nominal input voltage Range Nominal input current Current flow Delay time Permissible cable length to the sensor Input Characteristic Curve Input Voltage V 30 lt Uyy lt 0 7 3 6 9 12 15 18 21 24 27 30 Sensor Supply Minimum sensor voltage Nominal current per channel Nominal current per device Overload protection Short circuit protection 7008_en_01 8 24 V DC 30 V DC lt Un lt 30 V DC 5 mA Linear in the range 1 V lt Uy lt 30 V ton 2 9 ms typical torr 2 6 ms typical lt 30m Typical Input Current mA 0 0 5 1 0 1 5 2 2 3 0 3 6 4 4 5 1 5 8 6 6 Us 1 V 600 mA 600 mA Electronic per device Electronic per device PHOENIX CONTACT 11 THE ON
9. evice The current status of the diagnostic data can be read by the device at any time For further information on the diagnostic data please refer to the FLS FLM PB SYS PRO UM E user manual Order No 26 99 07 9 7008 _en_01 PHOENIX CONTACT 9 Technical Data Device Dimensions 168 mm 6 614 70 mm General Data Order Designation Order No Housing dimensions width x height x depth Weight Type of sensor connection Permissible temperature operation Permissible temperature storage transport Permissible humidity storage transport onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI 8 M12 178 mm i 7 008 ER a ap d glx 5 A 7008A006 FLM BK PB M12 DI 8 M12 27 36 330 70 mm x 178 mm x 49 3 mm 285 g approximately 2 3 or 4 wire technology 25 C to 60 C 25 C to 85 C 95 ic For a short period slight condensation may appear on the housing Permissible air pressure operation Permissible air pressure Storage transport Degree of protection Class of protection Mechanical Requirements Vibration test Sinusoidal vibrations according to EN 60068 2 6 Shock test according to EN 60068 2 27 80 kPa to 106 kPa up to 2 000 m above sea level 70 kPa to 106 kPa up to 3 000 m above sea level IP65 IP67 according to IEC 60529 Class 3 according to VDE 0106 IEC 60536 5g load in each space dire
10. ne Product Range user manual Configuring a PROFIBUS DP System Using Devices in the Fieldline Product Range user manual 7008_en_01 Order Designation FLS FLM SYS INST UM E Order No 26 98 97 3 FLS FLM PB SYS PROUME 2699079 Pcs Pkt J I PHOENIX CONTACT 13
11. z Local bus stopped Red yellow There are differences between specified and current configuration Flashing 1 Hz Green yellow Preprogrammed error values are written to the outputs Flashing 1 Hz PLC stopped or PROFIBUS connection interrupted cable connector Yellow flashing PCP error on a local bus device 1 Hz Voltage not present Green red LED Voltage supply for inputs IN1 to IN8 Voltage supply present Red ON Overload or voltage supply too low OFF Voltage supply not present 7008 _en_01 PHOENIX CONTACT 6 Internal Circuit Diagram Figure 9 7008 _en_01 7008A010 Internal wiring of the connection points onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI8 M12 Functional earth ground Optocoupler Protocol chip Local bus protocol unit Power supply unit with electrical isolation S E aA Input Ht p LED 4 Electrically isolated area ITT For information on electrically isolated areas please refer to page 12 PHOENIX CONTACT 7 onlinecomponents com THE ONLINE DISTRIBUTOR OF ELECTRONIC COMPONENTS FLM BK PB M12 DI8 M12 Connection Example 6954A008 Figure 10 Typical sensor connections Connection Notes Meet noise immunity requirements Connect FE using a mounting screw or a cable connection to the FE connection latch when mounting on a non conductive surface Ensure degree of protection To ensure I