Home

Quick Installation Guide - Green Power Technologie

image

Contents

1. SmartLogger1000 Quick Installation Guide Issue 05 Date 2013 12 15 Sa HUAWEI TECHNOLOGIES CO LTD HUAWEI Copyright Huawei Technologies Co Ltd 2013 All rights reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Trademarks and Permissions Wiz Huawei and other Huawei trademarks are trademarks of Huawei Technologies Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders Notice The purchased products services and features are stipulated by the contract made between Huawei and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensure accuracy of the contents but all statements information and recommendations in this document do not constitute a warranty of any kind express or implied Huawei Technologies Co Ltd Address Huawei Industrial Base Bantian Longgang Shenzhen 518129 People s Re
2. RS485 differential signal RS485 differential signal RS485 differential signal COM2 port RS485 differential signal RS485 differential signal COM3 port RS485 differential signal e Connect the SmartLogger to multiple inverters in daisy chain that is first connect the RS485 OUT port of one inverter to the RS485 IN port of another inverter and then connect the RS485 port of the first inverter to the COM port of the SmartLogger Issue 05 2013 12 15 Huawei Proprietary and Confidential 9 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide Environment detector Inverter Inverter Inverter Inverter Inverter ILO1NC0001 LL NOTE o A maximum of 20 devices are in one daisy chain e Ifan environmental monitoring instrument is to be connected connect it at the end of the chain Set the address for the environmental monitoring instrument to e Set Match Resistance of every inverter at the end of the daisy chain to Connect in Comm Param For details about this see the SUN2000 SKTL 25KTL User Manual e The addresses for all devices in the daisy chain should be within the searching scope set in the SmartLogger and they must differ from each other Otherwise the communications would fail between the device and the SmartLogger e Baud rate of all the devices in one daisy chain should stay consistent with those of the SmartLogger Connecting the SmartLogger
3. same network segment For example if the IP address for the SmartLogger is 192 168 0 10 the IP address for the PC can be 192 168 0 11 The subnet mask and the gateway of the PC should stay consistent with those of the SmartLogger Internet Protocol Version 4 TCP 1Pv4 Properties General oa can get IP settings assigned automatically if your network supports pability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically i Use the following IP address IP address Subnet mask Default gateway Obtain ONS server address automatically i Use the following ONS server addresses Preferred DNS server Alternate DNS server IL Validate settings upon exit 2 Log into the WEBUI through a browser The address for the WEBUI is by default the same as the IP address for the SmartLogger that is http 192 168 0 10 Issue 05 2013 12 15 Huawei Proprietary and Confidential 14 Copyright Huawei Technologies Co Ltd
4. to set the communications parameters refer to Setting Communications Parameters in the SUN2000 8KTL 25KTL User Manual and SUN8000 500KTL User Manual Connect the output terminal of the power adapter for the SmartLogger to the power port POWER and the input terminal to the AC socket under the Settings Wait for the SmartLogger to search for inverters After the search 1s completed the SmartLogger automatically connects to all inverters Alternatively you can skip this operation and manually search for add or delete inverters in follow up operations Optional Add the environmental monitoring instrument manually NOTICE Before you add the EMI manually log in to the WebUI and set related parameters Optional Start the monitoring terminal and set Ethernet and NetEco parameters on the SmartLogger A NOTICE e When starting the SmartLogger use only the 12 V power adapter shipped along with the shell If adapters of other models are used the SmartLogger may be damaged Set the search address segment and baud rate for the RS485 port on the SmartLogger monitoring panel If the SmartLogger is powered on for the first time set the search address segment and baud rate for the RS485 port in the Wizard If it is not powered on for the first time set the parameters in the Comm Param e Log into the SmartLogger on the monitoring panel When you log in to the Settings page or Maintenance page an identity authentication is require
5. and environmental monitoring instruments Checking Deliverables After unpacking the SmartLogger check whether deliverables are intact and complete If any damage is found or any component is missing contact the dealer 1 2 3 IS01WC0006 2 1 Adapter adapter type depends on the country specified in the order Issue 05 2013 12 15 Huawei Proprietary and Confidential 2 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide Network cable 2 2 meters long DI CRI CIONI CIN Screws used to secure the SmartLogger to the wall Auxiliary documents including the quick installation guide in paper copies and user manual in CD ROM Tools Prepare tools required for installation and electrical connections Hammer drill Diagonal pliers Wire stripper Rubber mallet Guarded blade Tn knife Cable cutter a Vacuum cleaner Marker Measuring tape _ Plumb line Safety uses Determining the Installation Position Comply with the following requirements when determining the installation position for the SmartLogger e Do not install the SmartLogger outdoors because it is protected to IP20 e Install the SmartLogger in a dry environment to protect it against water The ambient temperature should range from 20 C to 60 C Issue 05 2013 12 15 Huawei Proprietary and Confidential 3 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Gu
6. d The initial password is 000001 Change the password as soon as possible to ensure the security of the user account For details about how to change the password refer to SmartLogger1000 User Manual Setting the Initialization Parameters for the SmartLogger The following figure shows how to set the initialization parameters for the SmartLogger Issue 05 2013 12 15 Huawei Proprietary and Confidential 12 Copyright Huawei Technologies Co Ltd SmartLogger1000 Quick Installation Guide Date amp Time kee 2015 07 16 Time 13 06 54 ime one UTUDublin DST Di sable HUAWEI Ethernet IP Address 192 166 0 10 subnet Mask 255 455 255 0 Gateway 192 168 0 1 DNS 1 192 168 amp 1 DHS 2 0 Of 0 Q Start initialization wizard submit ESC Cancel al Enter search Address Segments o d amp b 1 MOI Ragab 001 020 Fsdab s 001 020 nitialization Wizard English HIT Deutsch Italiano Initialization search Devices Search devices now ESC Lancel pel Enter You can connect a PC to the SmartLogger by a network cable or through network devices such as a hub or a router Connect a PC to the SmartLogger Issue 05 2013 12 15 Huawei Proprietary and Confidential 13 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide ILO11C3005 1 When setting the Internet protocol set the IP addresses of the PC and the SmartLogger in the
7. ide e The communication distance for the RS485 port should be less than 1000 m and for the Ethernet less than 100 m e Install the SmartLogger at an appropriate height for the user s ease to view and operate on the monitoring panel Do not place the SmartLogger upside down Ensure that the heat dissipation holes are facing upwards preventing dust from entering the SmartLogger and reducing its service life If you install the SmartLogger on a wall or along a guide rail the area for connecting cables should be downwards e The SmartLogger is at least 100 mm away from the neighboring objects on both sides the top side and the bottom side respectively gt 100 mm gt 100 mm ILO1SC0001 Installing the SmartLogger on a Desk 1 Take the SmartLogger out of the package 2 Place the SmartLogger on a horizontal desk Mounting the SmartLogger on a Wall 1 The following figure shows the position of the installation holes Use a plumb line to ensure that the centric line of the hole is vertical to the ground Issue 05 2013 12 15 Huawei Proprietary and Confidential 4 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide awe TH a T ILO1SC0002 2 Drill holes by using a hammer drill and install expansion tubes and screws 24 25 mm i Sy ver ILO1HC0001 y 4 DI Table 1 2 describes the operations shown in the preceding figure Table 1 2 Drilli
8. ing instrument to the COM port of the SmartLogger by using shielded cables recommended CAT 5E outdoor shielded network cable ILO11C3006 The RS485 communications port for the SUN2000 is an RJ45 port which is connected over a crystal plug 1 8 IS01ZC0011 Table 1 3 lists the cable colors and functions side view without the fastener Table 1 3 Cable colors and functions White and orange RS485A RS485 differential signal RS485B RS485 differential signal RS485A RS485 differential signal White and blue RS485B RS485 differential signal White and green PGND Issue 05 2013 12 15 Huawei Proprietary and Confidential 7 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide 7 White and brown PGND The following figure shows the RS485 wiring terminals of the SUN8000 1U01ZC0001 Ports 07 08 09 10 11 and 12 are communications ports Table 1 4 describes the functions of these ports Table 1 4 Port description COSE CS oooO O LOR ess RsS ateena There are three COM ports for the RS485 communications of the SmartLogger COMI COM2 and COM3 Issue 05 2013 12 15 Huawei Proprietary and Confidential 8 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide ILO1WC0007 Table 1 5 describes the definition of the COM ports Table 1 5 COM port description NC Reserved NC Reserved COMI port
9. ng holes and installing expansion tubes and screws Step Operation Put a hammer drill with a D6 drill bit on a marked hole position perpendicularly against the wall and drill holes with a depth of 24 25 mm Insert the screw into the expansion tube until the screw heads are 7 5 mm to 8 mm away from the wall 1 2 Vertically insert an expansion bolt into a hole and knock the expansion bolt completely into the hole using a rubber mallet Install the expansion tubes and screws The guide rails are not delivered together with the SmartLogger If you need to mount the SmartLogger along a guide rail prepare a 35 mm wide guide rail Issue 05 2013 12 15 Huawei Proprietary and Confidential gt Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide 1 Hold both sides of the SmartLogger keep it parallel with the guide rail and then tilt it slightly to insert its upper hooks into the guide rail ILO1HC0002 2 Hold the two lower corners of the SmartLogger pull it downwards appropriately and then push it towards the guide rail When you hear a click sound the SmartLogger is successfully mounted along the guide rail ILO1HC0003 Issue 05 2013 12 15 Huawei Proprietary and Confidential 6 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide Electrical Connections This section describes how to connect the SUN2000 SUN8000 and an environmental monitor
10. public of China Website http enterprise huawei com Huawei Proprietary and Confidential TUTAS A Copyright Huawei Technologies Co Ltd i SmartLogger 1000 Quick Installation Guide The quick installation guide introduces the SmartLogger1000 SmartLogger in terms of installation electrical connections and initialization parameters For more detailed information see the related user manual You can download the latest documents from http enterprise huawei com Appearance Front View of the Shell 140 mm 225 mm ILO1WC0001 e Bottom of the Shell DI _ ZZZ POWER FE RS232 Alt Al2 GND1 1 4 GND2 COMI COM2 COM3 Ep EE NO COM NO COM NO COM NC NC L H NC NC ILO1WC0004 The following table describes functions of each port of the SmartLogger as shown in Table 1 1 Table 1 1 Port description Power supply 12 V DC E emme O Someso rores RS232 Connects to external RS232 devices reserved A Analog input 12 V current type signal reserved Issue 05 2013 12 15 Huawei Proprietary and Confidential 1 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide DI Digital parameter input Connects to the power grid scheduling signal controlled by dry contacts DO Digital parameter output Relay output Connects to pulse output Reserved power meters eax CS DC COMI COM3 RS485 Supports three RS485 ports and connects to inverters
11. to a Ripple Control Receiver In Germany and some European areas a ripple control receiver is used to convert a power grid scheduling signal to a dry contact signal in which a dry contact is required The following figure shows the DI ports on the SmartLogger ILO1WC0008 Table 1 6 describes the definition of the DI ports Issue 05 2013 12 15 Huawei Proprietary and Confidential 10 Copyright Huawei Technologies Co Ltd SmartLogger 1000 Quick Installation Guide Table 1 6 DI port description Functions Active power reduction DI 1 The following figure shows how to connect the Smart Logger to the ripple control receiver IL011C3010 A NOTICE When active power remote control and reactive power remote control are supported only one out of the four outputs of each ripple control receiver can be closed Power on Process Power on the devices in the following sequence Inverter gt SmartLogger gt Monitoring terminal LU NOTE The monitoring terminal refers to a PC where the NetEco1000 is installed Issue 05 2013 12 15 Huawei Proprietary and Confidential 11 Copyright Huawei Technologies Co Ltd SmartLogger1000 Quick Installation Guide Check and ensure all cables are correctly connected and secured before powering on the SmartLogger Start the inverter and correctly set the communications parameters including Address and Baudrate on the monitoring panel For details about how