Home

ICC19x User Manual 001 E

image

Contents

1. User Manual 9 02009 Fastwel v 001 E Line Terminators Fastwel 4 19 4 Line Terminators The 12 slot ICC192 cage backplane includes a number of passive components IOW IOR SMEMW and SMEMR signals are pulled to GND through serially connected 470 O resistor and 56 pF capacitor To reduce signal bounce in long lines it is possible to install 4 7 10 kO SIP resistor arrays RP1 RP5 RP1 DO D7 RP2 A12 A19 RP3 A4 A11 RP4 AO RP5 IOW IOR MEMW MEMR Termination to 5V only Using resistive networks in SIP packages with different internal circuitry it is possible to terminate signal lines in one of the following ways To 5V first RPx package pin to the first socket contact SIP array BOURNS 460610 101 472 or similar To ground first RPx SIP package pin to the last socket contact SIP array BOURNS 460610 101 472 or similar To ground and to 5V simultaneously use BOURNS 460610 104 472 SIP resistor array or similar 19 User Manual 10 2009 Fastwel v 001 E Fastwel Connectors Pinouts ICC19x 5 Connectors Pinouts ISA connector rows A and B A1 IOCHK B1 GND A2 D7 B2 RESET A3 D6 B3 5V A4 D5 B4 IRQ2 A5 D4 B5 5V A6 D3 B6 DRQ2 A7 D2 B7 12V A8 D1 B8 Reserved A9 DO B9 12V A10 IOCHRDY B10 GND A11 AEN B11 ME
2. 22 86 mm 9 10 in There are openings on the side walls for fastening of power supply unit or other accessories Mounting a 51xx series power supply unit on the side wall increases unit width by 50 8 mm 2 in 19 User Manual 7 02009 Fastwel v 001 E Installation Fastwel 4 ICC19x 2 Installation Position the cage so that the open side looks up the power supply unit if installed is on the right and the backplane at the bottom Ensure the correct orientation of the card to be inserted slide the card down along the guides into an ISA socket on the backplane applying moderate pressure on the upper edge of the card Correct orientation of a MicroPC module O Edge connector contacts A31 and B31 Backplane MicroPC module Edge connector contacts A1 and B1 O Attention A Incorrect orientation with 180 rotation leads to serious damage to the module ICC19x User Manual 8 2009 Fastwel v 001 E Fastwel ICC19x Power Connectors 3 Power Connectors ICC190 ICC192 and ICC194 cages have two power connectors P1 and P2 with latches One of them is used to connect a 51xx series power supply unit another one serves as a power output for external devices The figure below illustrates their contacts designation ICC193 cage has one power connector with WAGO clip contacts P1 P2 5V 5V DG DG V V DG digital ground V 12V V 12V 19
3. N N L F1 Qo A w Note xX Another wall has mirror layout 2009 Fastwel v 001 E 19 User Manual
4. Fastwel T MICR 190 ICC191 192 193 160194 icroPC Card Cages User Manual Product Title ICC19x Document name ICC19x User Manual Manual version 001 E Ref doc ICC19x 1 Copyright O 2009 Fastwel Co Ltd All rights reserved Revision Record 001 Initial version 190 191 ICC192 ICC193 ICC194 March 2009 Contact Information Fastwel Co Ltd Fastwel Corporation US Address 108 Profsoyuznaya st 45 Main Street Suite 319 Moscow 117437 Brooklyn New York 11201 Russian Federation USA Tel 7 495 232 1681 1 718 554 3686 Fax 7 495 232 1654 1 718 797 0600 Toll free 1 877 787 8443 1 877 RURUGGED E mail info fastwel com info fastwelcorp com Web http www fastwel com Fastwel Lee ICC19x Table of Contents Table of G ntents E 1 Notation CONVENT ONS 2 General Safety Precautions uu u au ei Unpacking Inspection and Handling Three Year Watranly U u tren ka ee nenn a Le Ek cerca chested 6 1 tiep 7 2 InStallatico iu SSS asa sasa 8 3 SI cae e Saa Aaa nan kenn 9 4 Line NECI U U u u 10 5 Connectors Pinouts U U U 11 6 DIMENSIONS L se
5. MW A12 A19 B12 MEMR A13 A18 B13 IOW A14 A17 B14 IOR A15 A16 B15 DACK3 A16 A15 B16 DRQS A17 A14 B17 DACK1 A18 A13 B18 DRQ1 A19 A12 B19 DACKO A20 A11 B20 CLOCK A21 A10 B21 IRQ7 A22 A9 B22 IRQ6 A23 A8 B23 IRQ5 A24 7 24 IRQ4 A25 A6 B25 IRQ3 A26 A5 B26 DACK2 A27 A4 B27 TC A28 A3 B28 ALE A29 A2 B29 45V A30 A1 0 OSC A31 0 B31 GND 19 User Manual 2009 Fastwel v 001 E Dimensions Fastwel Lee ICC19x 6 Dimensions 6 1 ICC190 ICC191 ICC192 ICC194 C D E F 31 11 mm 86 36 mm 31 11 mm 8 38 mm ICC190 194 191 192 190 194 191 192 1 225 in 3 400 in 1 225 in 0 330 in 143 89 mm 189 61mm 235 33 mm 326 70 mm 160 65 mm 206 37 mm 252 09 mm 343 50 mm 5 665 in 7 465 in 9 265 in 12 86 in 6 325 in 8 125 in 9 925 in 13 50 in 19 User Manual 2009 Fastwel 0 01 E Dimensions Fastwel Z ICC19x 6 2 ICC193 Front view Top view ICC19x User Manual 13 2009 Fastwel v 001 E Fastwel ICC19x Dimensions 6 3 Side Walls Openings 226 4121 47 NE 11 4 11 4 38 e L d i N 9 5 N Y e o o 5 ES 3 Y a N P 40 6 En 452 i o _ 124 5 25
6. ault free operation Its design provides conformance to all related safety requirements However the life of this product can be seriously shortened by improper handling and incorrect operation That is why it is necessary to follow general safety and operational instructions below A A x Warning All operations on this device must be carried out by sufficiently skilled personnel only Warning When handling this product special care must be taken not to hit the heatsink if installed against another rigid object Also be careful not to drop the product since this may cause damage to the heatsink CPU or other sensitive components as well Please keep in mind that any physical damage to this product is not covered under warranty Note This product is guaranteed to operate within the published temperature ranges and relevant conditions However prolonged operation near the maximum temperature is not recommended by Fastwel or by electronic chip manufacturers due to thermal stress related failure mechanisms These mechanisms are common to all silicon devices they can reduce the MTBF of the product by increasing the failure probability Prolonged operation at the lower limits of the temperature ranges has no limitations Caution Electric Shock Before installing this product into a system and before installing other devices on it always ensure that your mains power is switched off Always disconnect external p
7. de names company logos and trademarks which are registered trademarks and therefore are property of their respective owners Fastwel welcomes suggestions remarks and proposals regarding the form and the content of this Manual 19 User Manual 1 02009 Fastwel v 001 E Fastwel ICC19x Notation Conventions Warning ESD Sensitive Device This symbol draws your attention to the information related to electro static sensitivity of your product and its components To keep product safety and operability it is necessary to handle it with care and follow the ESD safety directions Warning This sign marks warnings about hot surfaces The surface of the heatsink and some components can get very hot during operation Take due care when handling avoid touching hot surfaces Caution Electric Shock This symbol warns about danger of electrical shock 60 V when touching products or parts of them Failure to observe the indicated precautions and directions may expose your life to danger and may lead to damage to your product Warning Information marked by this symbol is essential for human and equipment safety Read this information attentively be watchful Note This symbol and title marks important information to be read attentively for your own benefit gt P P P ICC19x User Manual 2 02009 Fastwel v 001 E Fastwel ICC19x General Safety Precautions This product was developed for f
8. eee cc med eee gems cn e eee came 12 6 1 IGC190 16C191 160192 ICG194 uu a n ka kk a annahm 12 6 2 UEM 13 6 3 Side Walls Openings All information in this document is provided for reference only with no warranty of its suitability for any specific purpose This information has been thoroughly checked and is believed to be entirely reliable and consistent with the product that it describes However Fastwel accepts no responsibility for inaccuracies omissions or their consequences as well as liability arising from the use or application of any product or example described in this document Fastwel Co Ltd reserves the right to change modify and improve this document or the products described in it at Fastwel s discretion without further notice Software described in this document is provided on an as is basis without warranty Fastwel assumes no liability for consequential or incidental damages originated by the use of this software This document contains information which is property of Fastwel Co Ltd It is not allowed to reproduce it or transmit by any means to translate the document or to convert it to any electronic form in full or in parts without antecedent written approval of Fastwel Co Ltd or one of its officially authorized agents Fastwel and Fastwel logo are trademarks owned by Fastwel Co Ltd Moscow Russian Federation In addition this document may inclu
9. es previously approved in writing by Fastwel 2 Products which have been subject to power supply reversal misuse neglect accident improper installation or storage Returning a product for repair 1 Apply to Fastwel company or to any of the Fastwel s official representatives for the Product Return Authorization 2 X Attach a failure inspection report with a product to be returned in the form accepted by customer with a description of the failure circumstances and symptoms 3 Carefully package the product in the antistatic bag in which the product had been supplied Failure to package in antistatic material will VOID all warranties Then package the product in a safe container for shipping 4 customer pays for shipping the product to Fastwel or to an official Fastwel representative or dealer 19 User Manual 6 02009 Fastwel v 001 E Description Fastwel ICC19x 1 Description ICC19x series includes Micro PC card cages designed for different number of cards it consists of the following products ICC190 4 ICC191 8 192 12 193 ICC194 The ICC19x card cages provide three sides fixing of cards Moreover to further improve mechanical stability an additional fixing plates can be used The plates are supplied with each of the card cages The passive backplane with ISA sockets is installed on the back side of the cage The slots spacing is
10. occurred during shipping or unpacking If damage is observed usually in the form of bent component leads or loose socketed components contact Fastwel s official distributor from which you have purchased the product for additional instructions Depending on the severity of the damage the product may even need to be returned to the factory for repair DO NOT apply power to the product if it has visible damage Doing so may cause further possibly irreparable damage as well as result in a fire or electric shock hazard If the product contains socketed components they should be inspected to make sure they are seated fully in their sockets 19 User Manual 4 02009 Fastwel v 001 E Fastwel Lee ICC19x Handling In performing all necessary installation and application operations please follow only the instructions supplied by the present manual In order to keep Fastwel s warranty you must not change or modify this product in any way other than specifically approved by Faswel or described in this manual Technical characteristics of the systems in which this product is installed such as operating temperature ranges and power supply parameters should conform to the requirements stated by this document Retain all the original packaging you will need it to pack the product for shipping in warranty cases or for safe storage Please pack the product for transportation in the way it was packed by the supplier When handling
11. oduct is carefully packed in an antistatic bag and in a carton box to protect it against possible damage and harmful influence during shipping Unpack the product indoors only at a temperature not less than 15 C and relative humidity not more than 70 Please note that if the product was exposed to the temperatures below 09 for a long time it is necessary to keep it at normal conditions for at least 24 hours before unpacking Do not keep the product close to a heat Source Following ESD precautions carefully take the product out of the shipping carton box Proper handling of the product is critical to ensure correct operation and long term reliability When unpacking the product and whenever handling it thereafter be sure to hold the module preferably by the front panel card edges or ejector handles Avoid touching the components and connectors Retain all original packaging at least until the warranty period is over You may need it for shipments or for storage of the product Initial Inspection Although the product is carefully packaged it is still possible that shipping damages may occur Careful inspection of the shipping carton can reveal evidence of damage or rough handling Should you notice that the package is damaged please notify the shipping service and the manufacturer as soon as possible Retain the damaged packing material for inspection After unpacking the product you should inspect it for visible damage that could have
12. ower supply cables during all handling and maintenance operations with this module to avoid serious danger of electrical shock ICC19x User Manual 3 2009 Fastwel v 001 E Fastwel ICC19x Unpacking Inspection and Handling Please read the manual carefully before unpacking the module or mounting the device into your system Keep in mind the following ESD Sensitive Device A Electronic modules and their components are sensitive to static electricity Even a non perceptible by human being static discharge can be sufficient to destroy or degrade a component s operation Therefore all handling operations and inspections of this product must be performed with due care in order to keep product integrity and operability Preferably unpack or pack this product only at EOS ESD safe workplaces Otherwise it is important to be electrically discharged before touching the product This can be done by touching a metal part of your system case with your hand or tool It is particularly important to observe anti static precautions when setting jumpers or replacing components 8 If the product contains batteries for RTC or memory back up ensure that the module is placed on conductive surfaces including anti static mats or sponges This can cause short circuit and result in damage to the battery and other components B Store this product in its protective packaging while it is not used for operational purposes Unpacking The pr
13. the product please remember that the module its components and connectors require delicate care Always keep in mind the ESD sensitivity of the product 19 User Manual 5 02009 Fastwel v 001 E Fastwel ICC19x Three Year Warranty Fastwel Co Ltd Fastwel warrants that its standard hardware products will be free from defects in materials and workmanship under normal use and service for the currently established warranty period Fastwel s only responsibility under this warranty is at its option to replace or repair any defective component part of such products free of charge Fastwel neither assumes nor authorizes any other liability in connection with the sale installation or use of its products Fastwel shall have no liability for direct or consequential damages of any kind arising out of sale delay in delivery installation or use of its products If a product should fail through Fastwel s fault during the warranty period it will be repaired free of charge For out of warranty repairs the customer will be invoiced for repair charges at current standard labor and materials rates Warranty period for Fastwel products is 36 months since the date of purchase The warranty set forth above does not extend to and shall not apply to 1 Products including software which have been repaired or altered by other than Fastwel personnel unless Buyer has properly altered or repaired the products in accordance with procedur

Download Pdf Manuals