1. 2 Hareonsolar Installation Safety instructions Maintenance Photovoltaic modules user manual Please carefully read the following installation and safety instructions Non compliance with these instructions may void the module warranty Purpose of this guide This guide contains information regarding the installation and safe handling of Hareon photovoltaic modules hereafter referred to as modules All instructions should be read and understood before attempting installation If there are any questions please contact your dealer or Hareon for further information The installer should conform to all safety precautions in the guide when installing modules Before installing a solar photovoltaic system the installer should become familiar with the mechanical and electrical requirements for photovoltaic systems Keep this guide in a safe place for future reference General Installing solar photovoltaic systems requires specialized skills and knowledge The installer assumes all risk of injury including risk of electric shock Module installation should be performed only by qualified persons All modules come with a permanently attached junction box and 12 AWG 4 mm wire terminated in PV connectors Your dealer can provide additional extension cables to simplify module wiring Exercise caution when wiring or handling modules exposed to sunlight When disconnecting wires connected to a photovoltaic module that is expo
2. installation shall be in accordance with CSA C22 1 Safety Standard for Electrical Installations Canadian Electrical Code Part 1 For best performance ensure that positive and negative DC wires run closely together avoiding loops WARNING Electrical shock hazard Do not touch bare conductors or other potentially energized parts Maintenance HAREON recommends the following maintenance items to ensure optimum performance of the module Clean the glass surface of the module as necessary Use water and a soft sponge or cloth for cleaning A mild non abrasive cleaning agent can be used if necessary Do not use dishwasher detergent Electrical and mechanical connections should be checked periodically by qualified personnel to verify that they are clean secure and undamaged 12 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar Check the electrical and mechanical connections periodically to verify that they are clean secure and undamaged Problems should only be investigated by qualified personnel Observe the maintenance instructions for all other components used in the system Artificially concentrated sunlight shall not be directed on the module Shutting down the system Completely cover system modules with an opaque material to prevent electricity from being generated while discon
3. 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar 3 Spring Washer M10 ib ZN 5 mm 4 Flat Washers M10 105 Coo T_T AV mm 5 Nonstandard Nut M10 8 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar eu 4 1 x 45 6 Nonstandard Bolt M10 SF x LF mm 7 Pressure Plate Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar 8 Crossbeam 1630 mm 10 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar Electrical Installation Grounding There is the grounding hole and grounding marking along either edge of the frame indicating a ground bonding location All module frames must be properly grounded All bolts nuts washers are stainless steel Observe all local electric codes and regulations Use solid uninsulated copper wire sizes 10 or 12 AWG The wire must have no nick Make the grounding wire connect to the bolt and tighten it Put M4 stainless steel bolt across M4stainless steel spring washer M4stainless steel flat washer 2 pc of stainless steel cupped washer with a diameter of
4. 4 Copper wire is winded on the bolt between two cupped washers and M4 stainless steel star washer and then through the grounding hole on the aluminum frame components M4 stainless steel flat washer And spring washer at last tighten them with the stainless steel M4 nut CTORQUE 4N M 11 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar ALUMINUN ALLOY rere FRAME SS STAR WASHER M4 CLASS CHA THA SS SPRING EF a WASHER M4 amidi TUT NO HH HH e A ik SS NUT MA COPPER WIRF IFTANETER SS BOLT H4 5o CUFFED WASHER WITH DIAMETER Aim Details for wiring in accordance with the NEC and that the grounding method of the frame of arrays shall comply with the NEC article 250 General electrical installation Do not use modules of different configurations in the same system This module is supplied with Multi Contact connectors for electrical connections Refer to Section 690 31 of the NEC to determine appropriate types and temperature ratings of conductors Wiring should be 12 AWG 4 mm minimum and must be temperature rated at 90 C minimum Completely cover system modules with an opaque material to prevent electricity from being generated while disconnecting conductors Refer to Sections 690 8 and 310 of the NEC to determine overcurrent conductor ampacity and size requirements In Canada
5. ection 690 8 of the National Electrical Code NEC for an additional multiplying factor of 125 percent 80 percent de rating which may be applicable General installation notes Drainage holes must not be covered with parts of the mounting system The junction box has a breather port which must be mounted facing downward and cannot be exposed to the rain The junction box should be on the higher side of the module when it is mounted in order to orient the breather port correctly Do not lift the module by grasping the module s junction box or electrical 2 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar leads Do not stand or step on module Do not drop the module or allow objects to fall on the module Do not place any heavy objects on the module Inappropriate transport and installation may damage the module glass or frame Mechanical Installation Selecting the location Select a suitable location for installation of the module For optimum performance the module must be facing true south in northern latitudes and true north in southern latitudes For detailed information on optimal module orientation refer to standard solar photovoltaic installation guides or a reputable solar installer or systems integrator The module should not be shaded at any time of the day Do not in
6. including product specification without limitations and suggestions does not constitute a warranty expressed or implied Hareon reserves the right to change the manual the product the specifications or product information sheets without prior notice Information about manufacturer Jiangyin Hareon Power Co Ltd ADD Huangtang Industrial Zone Huanzhen North Road Xuxiake Town Jiangyin Jiangsu P R China Please consult your dealer or the manufacturer concerning the warranty of your modules If you have any further questions your dealer will gladly assist you Subject to technical modifications without notice 14 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com
7. necting conductors Disconnect system from all power sources in accordance with instructions for all other components used in the system The system should now be out of operation and can be dismantled In doing so observe the all safety instructions as applicable to installation Electrical ratings of the concerned modules The electrical characteristics are within 10 of the indicated values of ISC VOC and Pmax under Standard Test Conditions irradiance of 1000 W m2 AM 1 5 spectrum and a cell temperature of 25 C 77 F 13 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar Disclaimer of liability Because the use of this manual and the conditions or methods of installation Operation use and maintenance of photovoltaic products are beyond Hareon s control Hareon does not accept responsibility and expressly disclaims liability for loss damage or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Hareon for any infringement of patents or other rights of third parties which may result from use of the PV product No license is granted by implication or otherwise under any patent or patent rights The information in this manual is based on Hareon s knowledge and experience and is believed to be reliable but such information
8. om 2 Hareonsolar RECOMMENDED TILT ANGLES FORA FIXED SYSTEM SITE LATITUDE IN DEGREES FIXED TILT ANGLE 0 To 15 15 15 TO 25 SAME AS LATITUDE 3 Other The recommended standoff height is 5 cm If other mounting means are employed this may affect the UL Listing Direction of module installation PV module are rectangle shaped PV module array longitudinal installation the way that installs the module by long side longitudinal is mostly used because the transverse installation the way that installs the module by long side transversely has less rain cleaning ability For distance between the modules longitudinal distance along the roof gradient should be enough for installation and disassembly transverse distance should be 3 10cm Other mounting methods are acceptable as long as the minimum requirements as described above Above requirements are only basic instructions For example on slant roof Mono crystalline Cell Module Poly crystalline Cell Module 6 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar module WD OO I OG PZ roof LH Nam Hr an NO Ja ans gin En gin Accessory 1 Hexagon Self locking Bolt M8 35 3 DS 2D e gt mm 2 Hexagon Nut M10 7 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip
9. sed to sunlight an electric arc may occur Arcs can cause burns start fires or otherwise create safety problems Exercise caution when disconnecting wiring on modules exposed to sunlight Photovoltaic solar modules convert light energy to direct current electrical energy and are designed for outdoor use Proper design of support structures is the responsibility of the system designer and installer Modules may be ground mounted pole mounted or mounted on rooftops Do not attempt to disassemble the module and do not remove any attached nameplates or components Doing so will void the warranty Do not apply paint or adhesive to the module Do not use mirrors or other hardware to artificially concentrate sunlight on the module When installing modules observe all applicable local regional and 1 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar national codes and regulations Obtain a building and or electrical permit where required Safety precautions for installing a solar photovoltaic system Solar modules produce electrical energy when exposed to sunlight Only connect modules with the same rated output current in series If modules are connected in series the total voltage is equal to the sum of the individual module voltages Only connect modules or series combinations of modules wi
10. stall the module near equipment or in locations where flammable gases can be generated or collected Selecting the proper mounting structure and hardware Observe all instructions and safety precautions included with the mounting system to be used with the module Do not drill holes in the glass surface of the module Doing so will void the warranty Do not drill additional mounting holes in the module frame Doing so will void the warranty Modules must be securely attached to the mounting structure using four mounting points for normal installation If heavy wind or snow loads are anticipated additional mounting points should also be used Load calculations are the responsibility of the system designer or installer The mounting structure and hardware must be made of durable corrosion and UV resistant material The modules have been evaluated by UL for mounting using the 8 provided mounting holes in the frame Each module or series string of modules so connected shall be provided with the maximum series fuse as specified Mounting methods 1 Mounting with Bolts The module must be attached and supported by at least four bolts through the indicated mounting holes Depending on the local wind and snow loads additional mounting points may be required The modules have been evaluated by UL for a maximum positive or negative design loading of 30 Ibs ft2 3 Add Xu Xiake Huangtang Industrial Park Jiang
11. th the same voltage in parallel If modules are connected in parallel the total current is equal to the sum of individual module or series combination currents Keep children well away from the system while transporting and installing mechanical and electrical components Completely cover all modules with an opaque material during installation to prevent electricity from being generated Do not wear metallic rings watchbands ear nose or lip rings or other metallic devices while installing or troubleshooting photovoltaic systems Use appropriate safety equipment insulated tools insulating gloves etc approved for use on electrical installations Observe the instructions and safety precautions for all other components used in the system including wiring and cables connectors DC breakers mounting hardware inverters etc Use only equipment connectors wiring and mounting hardware suitable for use in a photovoltaic system Always use the same type of module within a particular photovoltaic system Under normal operating conditions PV modules will produce currents and voltages that are different than those listed in the date sheet Data sheet values are applicable at standard test data Short circuit current and open circuit voltages should be multiplied by a factor of 1 25 when determining component voltage ratings conductor ampacity fuse sizes and size of controls connected to the module or system output Refer to S
12. yin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar Mono crystalline Cell Module Back view Junction box Ground holes Back view Ground holes 2 Mounting solar modules with bracket on flat roof and ground Fasten bracket on flat roof or ground first fasten solar modules on bracket use nuts to fasten bracket The bracket would endure 20 years and is made of anticorrosive material Temperature zinc steels and Stainless steel is recommended The bracket should be solid enough to resist continuous load pressure from wind snow earthquake and other outside force 4 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar com 2 Hareonsolar Use insulation materials to isolate different metal like stainless steel aluminum This would prevent corrosion insert screw into flat gasket insert screw into installation hole both on the modules and supporting frame insert screw into flat gasket and spring gasket then apply nut on the screw fasten It A2 70 M8SCREW FLAT GASKET SPRING GASKET MS NUT refer to the following form for supporting bracket s slope angle 5 Add Xu Xiake Huangtang Industrial Park Jiangyin Jiangsu China Zip 214407 Tel 86 510 86530222 Fax 86 510 86530828 Website www hareonsolar c

Download Pdf Manuals

image

Related Search

Installation installation installation assistant installation directory installation folder installation media installation file installation manager installation wizard installation art installation assistant windows 11 installation solar power system installation made easy installation status report installation floater installation of mini split air conditioner installation definition installation solar panels installation synonym installation status installation guide installation instructions installation file download installation manual installation has failed discord installation icon