Home
CC-2 canaletto colour corrector user manual
Contents
1. 40893300 g 2 EHV 1 td Em iH rodd ernie Figure 8 Location Of I Bus Termination Link 2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com
2. 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 2 Installation e l Installation of the CC 2 product If this unit is already pre installed in a flexiBox FB 9 or a maxiBox with either a local or a remote panel from the factory then refer to the Hardware Installation Guide which will be enclosed with the system If this unit is pre installed in a miniBox MB 9 then also refer to the Hardware Installation Guide which will be enclosed with the system If this unit has been ordered separately we assume here that you already have a flexiBox system with a Flexipanel and that the flexiBox has at least two spare slots above each other for the CC 2 card 2 2 Installing the CC e into a flexiBox To install the CC 2 into a flexiBox it is desirable but not necessary to power down the flexiBox Follow these instructions On the rear of the flexiBox are 6 slots for Products Remove any spare blanking plate There are 2 off M2 5 Screws which require unfastening for each blanking plate Slide the Product PCB into the spare slot and firmly push it home Use the two thumbscrews to fasten the unit in place Now refer to the GeNETics User Guide If your system consists of a single flexiBox with a single flexiPanel then refer to the section titled flexiPanel Auto Set up If your system is part of a network with more than one flexiPanel then refer to the section titled flexiPanel Manual Set up This will guide you thro
3. Fax 44 0 1923 256 100 email eesales eyeheight com Menu 40 43 Low clip control menu Heading Automation Function LoClip 1 to 511 This option sets the level of the low Level 7 1 default is 64 clip point to 50 8 0 0 41 LoKnee 1t0 511 This option sets the level of the low Level 7 1 default is 64 knee point to 50 8 0 0 a NA None 43 Back N A Pressing this button will take the user back to the Legaliser clip control menu Menu 44 47 High clip control menu Menu Num Heading Automation Function 44 HiClip 512 to This option sets the level of the high Level 50 9 1022 clip point to 109 default is 943 100 45 HiKnee 512 to This option sets the level of the high Level 50 9 1022 knee point to 109 default Is 943 100 146 NA Nome 47 Back N A Pressing this button will take the user back to the Legaliser clip control menu I5 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 48 51 Ring control menus Menu Num Heading Automation Function 48 Ring 0 Off Pressing this will select the mode Supr n 1 Auto 2 Man of the ring suppression off Default is Off automatic or manual 49 LoRing O to 511 This option sets the level of the Threshold default is 60 low ring t
4. on default Memory Recall 1 Recall Pressing this will recall the power on Pow On default settings Memory ma 1 1 Reset Pr this will reset the system FH BACK Hau this button will take the user back to the main menu Menu 76 79 Top Level Controls Menu Num Menu Num Heading Automation Function SAFE 0 on This Switches on and off the ACTION 1 off currently selected area Pressing the Red switch next to this one and adjusting the rotary digipots with the lighted green LED s chooses the Selected area None When this button is pressed to Green The Three line display in the window indicates the three options which can be changed by adjusting the three rotary digipots A B and C Digipot A an Determines the basic Function un Selects Safe Action option I9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com selects Safe Caption option Selects Digital Edge option Selects the An Edge option Digipot B Determines the Screen Format Standard 4 3 Screen Standard 16 9 Screen 16 9 Shoot to protect 4 3 16 9 Shoot to protect 14 9 4 3 Shoot to protect 16 9 Digipot C Determines the Style of Indicate Thin White lines are used Thick White lines are used Shade is used for danger area Black is used for danger area 0 S Action
5. 1 S Capt 2 DigEdge 3 An Edge Level B 0 4 3 1 16 9 2 16p4 3 3 16p149 4 43p16 9 Level C O Thin 1 Thick 2 Shade 3 Black 78 Blank 79 BACK none Go To the Utils submenu Menu 80 83 RGB Gamma values Menu Num Heading Automation Function 80 Red 0x28 gt 0x1fff This option sets the Red Gamma Gamma The action depends on menu 85 81 Green 0x28 gt 0x1fff This option sets the Green Gamma Gamma The action depends on menu 85 82 Blue 0x28 gt 0x1fff This option sets the Blue Gamma Gamma The action depends on menu 85 83 Back N A Pressing this button will take the user back to the main menu 20 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 84 87 RGB Gamma values Menu Num Heading Automation Function 84 Gamma O Full 1 Fixed Pressing this will select whether Range Default is the gamma function acts over the Fixed entire range 0 1023 or has two fixed points 64 940 The latter is the normal mode of operation 85 Gamma 0 Ganged In Ganged mode the RGB mode 1 RGB Gamma controls in Separate menus 80 gt 82 act together track as a master gamma In RGBsep mode the RG and B gamma can be individually adjusted 86 Blue 0x28 gt 0x1 fff This option sets the Blue Gamma Gamma The action depends on m
6. 2 eyeheight CC Z canaletto SDI colo user manual Table of Contents SEE OE EE E N A 4 1 1 Applications for the CC 2 rarrrnrnnnennannenrnnnennansrnnnnsnnnnnsrnnnnennnnsennnnennnnseen 5 1 2 Associated Equipment for the CG 2 rrrarnrnnarnennnrrvnnnnrrnnnnrnnnnnennnnnrnnnnnen 5 21 EET 5 T2252 GONWO B 1 ACCS EEE 6 Z SEENE sese E ee ee ee aa ss er ee er es 7 21 Installation of IheG62 produt anne aa 7 2 2 Installing the CC 2 into a flexiBox rrrrrnnrrrrnnrerrannerrnnrevnanrnnnnnrnnnnnennnnnen 7 2 3 Connecting Video to AN CC 2 rosserie niinen EEE EEn 7 2 4 Connecting Panels to the CC 2 azuuuesssneenennnenennnnennennennnnnnnn nennen 8 JEAN se 9 3 1 Manual control of the CC 2 rrrnnnnnnnnrerrnnnenrnnnenrnnnennnnnennansnnnnsnnnnnnnnnnnenn 9 3 2 Automation Control of the CC 2 rrrnnrrrrnnnrnrannrrrannrnnnnrennansnnnnnrnnnnnnnnnnen 9 3 3 Operational Menus for the CC 2 rrrrannrnrnnnrvrnnnenrnnnennnnnennnnnnnnnnennnnnennnnn 10 Ne ee LEE eo 070 ONCRUEEREENEENE NENNEN E E 22 4 1 Technical Specification for the CG 2 rrnrnvrnnrnvvnnrrevnnrrennnrrevnnrrennnrrennn 22 4 2 Jumpering the I BUS CAN BUS Termination rrnnrrennnnvrvnrnnvrennnnvne 22 m eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Table of Figures Figur
7. OSD gt VTR 7 eg PGM gt Figure 2 Connection of a CC 2 colour corrector le Associated Equipment for the CC 2 The CC 2 is amodule and requires both a chassis and a control surface to function 1 2 1 Chassis Types e flexiBox is a 1RU chassis The order code is FB 9 This will hold a maximum of 6 CC 2 Modules with Hot Swap redundant PSU option and Hot Swap CC 2 modules e maxiBox is an alternative low cost IRU chassis The order code is MX 9 This also will hold a maximum of 6 CC 2 modules but it has no redundant PSU option and the CC 2 units must be factory fitted u eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com l e 2 Control Surfaces e flexiPanel is a IRU control surface that fits on the Front of a 1RU flexiBox The order code is FP 9 A FlexiPanel can also be used in conjunction with a miniBox in this case the extra accessory Order code RR 9 will be required e FP 10 is a desk mounting control surface Order code FP 10 This unit is a modular unit which can be used in conjunction with the units below eyeheight Figure 4 FP 10 desktop modular panel ae eyeheight Figure 5 FP 9 1RU modular panel es eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44
8. X Automation Protocol is used only for the PresTX Presentation Mixer and channel branding system In this case an AU 2 Automation card is also required Refer to the PresTX Product manual On most flexiBoxes later than 1 10 02 the RS422 port has been replaced by a D Bus Port The D Bus port is for High Speed data transfer and is not used for serial control In order to achieve serial control of any products on an Bus network Eyeheight Ltd have developed a RS232 gt bus converter dongle DG 9 which enables greater flexibility of products on the I Bus network whilst using the same protocols as the RS422 port Please refer to the User guide for the DG 9 eyeheight dongle and set up software 9 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 3 Operational Menus for the CC 2 Menu 00 03 Top level controls Menu Num Heading Automation Function 0 Master N A Pressing this button will select the MASTER control menus 1 Grade N A Pressing this button will select the Individual GRADE control menus 2 Utils N A Pressing this button will select the onboard utilities such as the legaliser 3 Memory N A Pressing this button will select the memory control menus Menu 04 07 Master controls Menu Num Heading Automation Function 4 LUMA N A Pres
9. ar of the resultant picture being rejected by broadcasters The CC 2 is a unit that will accept one standard SDI video input and has three SDI outputs a loop program out and an indicate out to highlight the illegal part of the picture The main features are e Full 10 bit processing e Simple individual control of RGB gain lift and master gamma e Overall luma chroma gain and black level adjustment e Overall hue correction e Gamut legalization as standard with EBU R103 2000 set up mode e Indicate output put shows clipped areas with individual R G and B indicators e Adjustable legalisation levels e Highly effective luma overshoot and undershoot suppression e EDH re insertion e 6 user memories e Integrated safe area generator on indicate output ia wets gt BARA bry 3 e 22a 2 mariah 7 1 N 8 o rs 5 a i Figure 1 The CC 2 colour correction PCB a eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com I Applications for the CC 2 Applications for the CC 2 include the following e Post production grading e Correcting level and colour errors in source material The CC 2 will be used in a situation where a device such as a caption generator is required to overlay captions onto a video background Loop CC 2 OP IIP
10. e 1 The CC 2 colour Correction PCB rrrnnrnrannennnnnrnrnnnnnnnnnnnnnnnnnnnnrnnnnnnnnnnee 4 Figure 2 Connection of a CC 2 colour corrector uuuenenenenennnnennnnnnnnnnnne nn 5 Figure 3 flexiBox with flexiPanel fitted u04400440040n0Renn nano nennen nenn nenn nenn 5 Figure 4 FP 10 desktop modular panel u002400024000enn nenne nenne nenn nenn nennen 6 Figure 5 FP 9 1RU modular panel uu 2u022400022000Rnne nenne nenne nenn nenn nenn nennen 6 Figure 6 Connections for a CC 2 module showing internal links 7 Figure 7 I Bus Connections and Termination ccccccccseseeceeeeeeeeeeeeeeeeseeeeeneees 8 Figure 8 Location Of I Bus Termination Link u0204002240 nenn enennenenne nennen 22 3 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com System Overview This manual describes the function of the CC 2 processing card When packaged as a system incorporating a 1RU chassis CC 2 processing card and control panel it is called canaletto The CC 2 is a simple cost effective colour correction system which will give individual control of R G and B Gain lifts and Gamma The system also inherently legalises the signal enabling the user to make full use of the colour correction without fe
11. east a 1 amp rating for pins 1 4 9 Cable Ilength should not exceed 250m Bus pins 2 amp 7 The I BUS Network requires terminating with 100 Ohms at each extreme end of the network Ensure that this is done either by an external 100 ohm resistor OR ONE Panel Product at each end has the termination set See the Genetics User Guide Under the sections Flexipanel Power I BUS Jumpers For the 4RU Panels see 4RU Panel FP 10 Jumpers for I BUS and 4RU Panel VP 10 SW 10 AP 10 Jumpers for I BUS Alternatively The termination can be set on a Product ie the MW 2 module Information about this is given in this manual Figure 7 I Bus Connections and Termination N B From 1 10 02 Eyeheight introduced a change in the flexiBox Chassis Most versions now have two 9 way connectors on the rear labelled Bus and D Bus The Bus connector is the same as the previously labelled Can B connector Although a maxiBox is shown in this diagram the same arrangement applies for a flexiBox chassis 8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 3 Operation 3 1 Manual control of the CC 2 Manual Control of the CC 2 is done using one or more of the following control surfaces e The 1RU FP 9 Flexipanel e The FP10 Desk mounting Panel The FP 9 and the FP 10 ha
12. emory Mem 2 number 2 62 Save 1 Save Pressing this will Save Memory Mem 3 number 3 vr eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Mem 3 number 3 63 Back N A Pressing this button will take the user back to the main menu Menu 64 67 Memory Controls Menu Heading Automation Function Num 64 Save 1 Save Pressing this will Save Memory Mem 4 number 4 65 Save 1 Save Pressing this will Save Memory Mem 5 number 5 66 Save 1 Save Pressing this will Save Memory Mem 6 number 6 67 Back N A Pressing this button will take the user back to the main menu Menu 68 71 Software version Menu Num Heading Automation Function 68 N A Info 70 CC 2 N A Info the top line is product 230103 identifier the middle is the date the Ver2 5 software was last changed and the last line is the software version 71 BACK N A Pressing this button will take the user back to the main menu I8 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 72 75 Top Level Controls Menu Num Heading Automation Function 72 Set As 1 save Pressing this will save the current Pow On set up as the power
13. enu 85 87 Back N A Pressing this button will take the user back to the main menu Pl eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com A Technical Appendix 4 1 Technical Specification for the CC 2 Number of Inputs Type of Inputs URE Serial Digital Video puts 75 Ohm Line Length At least 200 Meters of PSF1 3 Typically 275 Meters Number of Outputs 3 Output BNC s per Card E Type Of Outputs 270Mbit Serial Digital Video Outputs 75 Ohm 800mV 5 consisting of 1 Fixed Input and 3 Jumper BNC Connections Configurable outputs One BNC not used This is only guaranteed on issue 2 or later cards Current Consumption lt 800mA at 5V Size 215mm by 100mm 4 2 Jumpering the I BUS CAN BUS Termination The I BUS Network is the control system under which all Products and Panels are networked together Under certain circumstances it is necessary to terminate the network This can be done on a Panel or a Product To terminate this product locate J6 on the CC 2 Processor Card supplied which is between U1 The large square chip and the Edge connector This is on the half of the card labelled CHP 100 Spartan2 Processor Jumper this with a 2mm link vil ut af 4 er Pa 1 rn TT TT 0 seg i p a ih LA ad x rd 3 t i p ate id 19 0120 9v002
14. hreshold point 6 8 to 0 0 51 2 50 HiRing 512 to 1023 This option sets the level of the Threshold default is 944 high ring threshold point 50 9 to 100 109 51 Back N A Pressing this button will take the user back to the Legaliser clip control menu Menu 52 55 Memory Controls Menu Heading Automation Function Num 52 MEM1 1 Recall Pressing this will recall Memory number 1 User Names can be programmed in to the memories using a keyboard See geNETics User guide section Giving product Memories names 53 MEM2 1 Recall Pressing this will recall Memory number 2 IG eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com 54 MEM3 1 Recall Pressing this will recall Memory number 3 55 Back N A Pressing this button will take the user back to the main menu Menu 56 59 Memory Controls Menu Heading Automation Function Num 56 MEM4 1 Recall Pressing this will recall Memory number 4 57 MEM5 1 Recall Pressing this will recall Memory number 5 58 MEM6 1 Recall Pressing this will recall Memory number 6 59 Back N A Pressing this button will take the user back to the main menu Menu 60 63 Memory Controls Menu Heading Automation Function Num 60 Save 1 Save Pressing this will Save Memory Mem 1 number 1 61 Save 1 Save Pressing this will Save M
15. ing Automation Function 28 Legalr N A Pressing this button will select the menu legaliser control menu S Area Pressing this button will select the menu Safe Area Generator control menu Menus 72375 Gamma Pressing this will select the menu Gamma control menus Back Pressing this button will take the user back to the main menu 19 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 32 35 Legaliser control menu Menu Num Heading Automation Function 32 Legalr 0 Off 1 On Pressing this will turn the legaliser Default is on or off On 33 CLIP N A Pressing this button will select the menu legaliser clip control menu 34 RING N A Pressing this button will select the menu legaliser ring control menu 35 Back N A Pressing this button will take the user back to the Utils menu Menu 36 39 Clip control menu Menu Num Heading Automation Function 36 LOW 512 to This option sets the Red offset Menu 511 default is O 37 HIGH 512 to This option sets the Red offset menu 911 default is O 38 1 NA Nome 39 Back N A Pressing this button will take the user back to the Legaliser control menu A eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000
16. rol menu Menu Num Heading Automation Function 16 Gain N A Pressing this button will select the menu grade gain control menu 17 Lift N A Pressing this button will select the menu grade lift control menu 18 N A None 19 Back N A Pressing this button will take the user back to the main menu Menu 20 23 Grade gain control menu Heading Automation Function Red Gain 0 to 4096 This option sets the Red gain O to 16 default is 256 1 00 Green 0 to 4096 This option sets the Green gain Gain default is O to 16 256 1 00 Blue Gain 0 to 4096 This option sets the Blue gain O to 16 default is 1 00 Back Pressing this button will take the user back to the main menu I2 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 24 27 Grade lift control menu Menu Num _ Heading __ Automation _ Funeion ________ Red Offset 512 to This option sets the Red offset 512 to 511 511 default is 0 25 Green 512 to This option sets the Green offset Offset 511 512 to default is 0 511 26 Blue 512 to This option sets the Blue offset Offset 511 512 to default is 0 511 27 Back N A Pressing this button will take the user back to the grade control menu Menu 28 31 Utils control menu Menu Num Head
17. sing this button will select the luma control menus 5 CHROMA N A Pressing this button will select the chroma control menus 6 GAMMA N A Pressing this button will select the gamma control menus 7 BACK N A Pressing this button will take the user back to the main menu IO eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 08 11 Luma control menu Menu Fe Heading Automation Function Luma Oto 511 This option sets the Luma gain Gain default is 0 256 199 7 100 0 9 Black Lift 254 to This option sets the black lift 29 255 28 9 default is 0 Loo d0 NA none 11 Back N A Pressing this button will take the user back to the master control menu Menu 12 15 Chroma control menu Heading Automation Function Chroma 0 to 511 This option sets the Chroma gain Gain default is 0 to 256 199 7 100 0 13 Hue 512 to This option sets the Hue rotation Rota n 511 default 180 to is O 180 ta NA None 15 Back N A Pressing this button will take the user back to the master control menu aie eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com Menu 16 19 Grade cont
18. ugh acquiring your product as a device on the flexiPanel 2 3 Connecting Video to an CC 2 A Typical Connection diagram for the CC 2 is shown below All signals are SDI CC 2 Processor Aln Pam Pgm Mon Mon Bin P B rn SB a safe Figure 6 Connections for a CC 2 module showing internal links 7 eyeheight Unit 34 Park House Watford Business Park Greenhill Crescent Watford Herts GB WD18 8PH Reg No 2855535 Telephone 44 0 1923 256 000 Fax 44 0 1923 256 100 email eesales eyeheight com The CC 2 Module has a number of user configurable jumpers which can change the function of the 5 SDI BNC Connectors These are shown along with their default configuration below These jumpers are found close to the BNC Connectors 2 4 Connecting Panels to the CC 2 The CC 2 may be operated using a FP 9 Flexipanel locally mounted For a more operational environment the CC 2 may be supplied with a desk mounting FP 10 unit and also possible a VP 10 Desk mounting Video T Bar manual transition unit For detailed information on connecting remote panels refer to the section Connection of Remote Panels to a flexiBox in the geNETics Hardware Installation Guide Below is shown a typical system consisting of an CC 2 in a flexiBox controlled by aremote FP 9 eyeheight Connect Pins 1 2 4 7 9 from chassis to panels 1 1 Use twisted pair AES Digital Audio cable for pins 2 and 7 Pins 1 4 9 carry power 0 5 Amp 13V Use cable with a l
19. ve identical manual control systems The FP 10 is simply a desktop version of the FP 9 The CC 2 is as are all genetics modules controlled using a set of MENUS Each of these menus contains up to 3 parameters that are adjusted using the rotary digipots The Menus define all of the adjustable operational parameters in the CC 2 Pressing the rotary digipots brings the parameter to its default value Device selection is done using the device select switches which when pressed will offer the name of the device in the LCD Window Modules can be acquired and then de acquired using the set up switch For a full description of the operation philosophy of the geNETics system refer to the geNETics User Guide section Operation of the flexiPanel A full list of the Menus and their functions are given in section 3 of this chapter 3 2 Automation Control of the CC 2 Automation of the geNETics products is achieved via an RS422 port This port is marked RS422 on the rear of a flexiBox For the port to work a flexiPanel MUST be connected locally on the front of the flexiBox Automation control of the CC 2 can be done using two protocol methods e geNETics Automation Protocol e PresTX Automation Protocol Genetics protocol is described in detail in the GeNETics User Guide section titled Automation Protocol on the geNETics Platform The menu list in section 3 of this chapter contains the data information for the protocol PresT
Download Pdf Manuals
Related Search
Related Contents
Enregistreur IC Eurovocs Suite Manuale Utente Manual - Hitech Mobiles 交換手順PDFファイル - (株)Hiro Network Anleitung 1 - Poolpowershop Optoma OP1022WTDS touch screen monitor Operation, Maintenance and Service Manual Copyright © All rights reserved.
Failed to retrieve file