Home

Additional Function Manual for ZFX-CD

image

Contents

1. ZFX C1_ C2_ CD Additional Functions Instructions gt MENU mode Setup Item Detail Decode condition Setup Item Setting Value Description Code type JAN EAN UPC default Selects the type of barcode to be read value Code39 Codebar NW 7 ITF Code 93 Code128 GS1 128 GS1 DataBar Pharmacode Timeout 1 to 9999 ms default Sets the timeout time in read processing A read error occurs if value 9999 measurement does not end after the preset timeout time is exceeded Check digit OFF Selects whether or not to insert a check digit This item is enabled only when the following barcode types are selected Codebar Code39 ITF Interleaved 2 of 5 When the other codes are selected this item is set to ON ON default value Composite component OFF default value ON Sets whether or not to support composite codes This item is enabled only when the following barcode types are selected Code128 GS1 128 GS1 DataBar Direction Pharma Horizontal mode default value Selects the reading direction This item is enabled only when Pharmacode is selected as the barcode type Vertical mode Reverse Pharma Sets whether or not to use the reverse mode This item is enabled only when Pharmacode is selected as the barcode type OFF default value ON Possible output results The following values can be output when expressions are set Item Description Judgment result
2. Character code Before conversion After conversion Comma amp h8540 Tab amp h854 1 Space amp h8542 CR amp h8543 LF amp h8544 Example Output of read results together with two expressions Read result ABC Expression DataO 123 Expression Data1 456 The output order is as follows 123 456 delimiter ABC delimiter Measurement control function This function enables control of the next measurement item to be executed based on the verification results with the master data The overall judgment result does not reflect the measurement items that are not executed Example Measurement of product A and product B are branched according to the verification results Measurement Item0 Barcode Measurement Item1 Pattern Search Measurement Item2 Area Measurement Item for Product A Measurement Item3 Area Measurement Item4 Pattern Search Measurement Item5 Area Measurement Item for Product B Measurement Item6 Area Setting master data 0 eRegister the barcode of product A eFirst meas Item No 1 Last meas Item No 3 Setting master data 1 Register the barcode of product B First meas Item No 4 Last meas Item No 6 LT Registering master data First meas Item No Last meas Item No p 2 Decode condition detailed settings Be Sure to set the detailed conditions for the barcode type Set other items as required By AUTO setting Code type Direction Pharma are set automatically
3. measurement items is executed OFF In the RUN mode the AUTO button does not function Save With AUTO Button This function enables AUTO setting to be automatically saved after AUTO execution in RUN mode All settings will be deleted if you turn the power OFF without saving the settings gt MENU mode System Operation Save With AUTO Button Setup Item Description ON Settings are saved immediately after AUTO Button in RUN mode is executed Settings are not deleted even if the power is turned OFF Note however that measurement is not possible while an AutoSave is being executed OFF AutoSave is not performed after AUTO Button in RUN mode is executed ZFX C1_ C2_ CD Additional Functions Instructions Parallel Commands The following commands were added Command Description Command code Parameter binary code DIZ DI6 DI5 Dl4 DIS DI2 DIM DIO AUTO setting Automatically batch sets all 1 measurement items AUTO setting content differs with each measurement item For details see AUTO Setting in Chapter 7 of the ZFX User s Manual Serial Commands According to the addition of measurement items MEASDATA command and MEASPARA command parameters were added MEASDATA command Barcode 2D Code Data No Parameter Output Range 0 Judgment result 0 OK 1 NG 2 not measured 1 Index 0 to 31 Master data No of verification results 2 Verification results OFF
4. JG The judgment result is output 0 OK 1 NG 2 not measured Index IN Outputs the verification results master model No 2 verification results OFF or read error 1 verification results NG 0 to 31 model No Num of characters N Outputs the read number of characters 0 to 1024 Characters Outputs the read text string Only codes that can be registered manually and 2 byte characters can be displayed as text string in the result display screen Other character codes including control codes that are read are displayed as spaces The read string is displayed up to 32 characters When more than 32 characters are read is displayed at the end of the string ZFX C1_ C2_ CD Additional Functions Instructions 2D Codes This function reads and verifies 2D codes Read results and verification results can also be output Measurement items to be executed from this measurement item onwards can also be specified according to the verification results This allows you to specify a measurement flow matched to the code type Eight 2D Code types can be read Data Matrix EC200 QR Code MicroQR Code PDF417 MicroPDF417 Maxi Code AZtec Code Codablock Setup Measurement Draw the measurement region then execute One 2D barcode is read in a single measurement region AUTO setting The code type and some of the When the measurement region contains multiple 2D decode conditions are automatically set codes the res
5. Master31 54 Partial verification 0 OFF 1 ON 55 Last compared digit 1 to 1024 56 First compared digit 1 to 1024 57 Output characters 0 OFF 1 ON 59 Error string 1 to 20 characters 60 Partial output 0 OFF 1 ON 61 Last output digit 1 to 1024 62 First output digit 1 to 1024 63 Measurement control 0 OFF 1 ON 64 Code type 0 Data Matrix EC200 1 QR Code 2 MicroQR Code 3 PDF417 4 MicroPDF417 5 Maxi Code 6 AZtec Code 7 Codablock 65 Timeout time ms 1 to 9999 66 Mirror 0 Normal 1 Reverse 67 Code color 0 Black 1 White 2 Black amp White 68 Shape Data Matrix 0 Square 1 Square amp Rectangle 71 Num of characters upper limit value 1 to 1024 72 Num of characters lower limit value 1 to 1024 74 Characters threshold 1 to 32 characters 155 N Master data for master data N 1 to 10 characters excluding NULL 187 N Verified master data for master data N 1 to 32 characters 219 N First meas Item No for master data N 1 to 127 ZFX C1_ CD 1 to 31 251 N Last meas Item No for master data N 1 to 127 ZFX C1_ CD 1 to 31 ZFX C1_ C2_ CD Additional Functions Instructions Multi Color Data No Parameter Range 53 Fill profile 0 OFF 1 ON 54 Calibration 0 OFF 1 ON 55 Coordinates mode 0 Normal 1 Pos correction 56 Auto THset 0 000 to 9999999 999 57 Area judgment upper limit 0 000 to 9999999 999 58 Area judgment lower limit 0 000 to 9999999 999 71 Individual area1 upper limit val
6. Setting Value Data Matrix EC200 QR Code MicroQR Code PDF417 MicroPDF417 Maxi Code AZtec Code Codablock 1 to 9999 ms default value 9999 Normal default value Reverse Black White Black amp White default value Description Selects the type of 2D Code to be read Sets the timeout time in read processing A read error occurs if measurement does not end after the preset timeout time is exceeded Sets normal or reverse as the image orientation Specifies the code color This item is enabled only when the following barcode types are selected Data Matrix PDF417 Shape Data Matrix Square default value Square amp Rectangle Possible output results Specifies the code shape This item is enabled only when the following barcode types are selected Data Matrix The following values can be output when expressions are set Item Description Judgment result JG The judgment result is output 0 OK 1 NG 2 not measured Index IN Outputs the verification results master model No 2 verification results OFF or read error 1 verification results NG 0 to 31 model No Num of characters N Characters Outputs the read number of characters 0 to 1024 Outputs the read text string Only codes that can be registered manually and 2 byte characters can be displayed as text string in the result display screen Other character code
7. it is the same as the characters in this menu Up to 32 characters can be set Check available characters in the ASCII table 2 byte characters 1 byte kana characters and control codes cannot be entered The following characters can be used as wildcards Wildcard for zero or more characters Wildcard for one character _JASCII code table p 3 ZFX C1_ C2_ CD Additional Functions Instructions Image adjustment if necessary The following items can be changed and set to the image of the measurement target gt MENU mode Setup Item Img Adj Item Select Camera Description Color filter Filtering BGS level For details refer to Chapter 3 Image Adjustment of the ZFX User s Manual Operation mode details if necessary Set items below as required gt MENU mode Setup Item Detail Function condition Setup Item Verification func Verified master data Setting Value OFF default value ON All master data default value Master data 0 to 31 Description When set to ON verification with the master data is executed Selects the model to be used for verification Partial verification Compared digit OFF default value ON 1 to 1024 default value first digit 1 last digit 1 The number of digits in the read results to be verified with the master data can be limited When Partial verification is set to ON set the first and last compare
8. or read error 1 Verification results NG 2 Num of characters 0 to 1024 3 Characters Text string 0 to 1024 characters Character codes that cannot be displayed e g control codes are displayed as spaces When text strings are output the following control codes are converted before they are output When setting text strings use the codes in the After conversion column Text code Before conversion After conversion Comma amp h2C amp h8540 Tab amp hO9 amp h854 1 Space amp h20 amp h8542 CR amp hOD amp h8543 LF amp hOA amp h8544 ZFX C1_ C2_ CD Additional Functions Instructions 15 16 Multi Color Data No Parameter Output Range 0 Judgment result 0 OK 1 NG 2 not measured 1 Individual area O to 9999999 999 2 Individual area2 O to 9999999 999 3 Individual area3 O to 9999999 999 4 Individual area4 O to 9999999 999 5 Individual reference area1 O to 9999999 999 6 Individual reference area2 O to 9999999 999 7 Individual reference area3 O to 9999999 999 8 Individual reference area4 O to 9999999 999 9 Individual difference area1 9999999 999 to 9999999 999 10 Individual difference area2 9999999 999 to 9999999 999 11 Individual difference area3 9999999 999 to 9999999 999 12 Individual difference area4 9999999 999 to 9999999 999 ZFX C1_ C2_ CD Additional Functions Instructions MEASPARA command Barcode Data No Paramet
9. the ASCII table 2 byte characters 1 byte kana characters and control codes cannot be entered The following characters can be used as wildcards Wildcard for zero or more characters Wildcard for one character LJ ASCII code table p 3 Rename This is the text string displayed as the verification result on the result display screen First meas Item No This is the Start No of measurement items to be executed when the measurement control is set to ON and the read text string match the master data Last meas Item No This is the End No of measurement items to be executed when the measurement control is set to ON and the read text string match the master data LT Measurement control p 5 When the manual registration screen is displayed after execution of AUTO setting unavailable characters in manual registration control codes 2 byte characters 1 byte kana characters etc are displayed as ZFX C1_ C2_ CD Additional Functions Instructions ASCII code table The following table shows the ASCII codes that can be used for manual registration of master data and also for registering characters of Limits Upper 4 bits Lower 4 bits Threshold This function sets the judgment conditions gt MENU mode Setup Item Limits Item Description Num of characters Sets the range of number of characters to be judged as OK Range 0 to 1024 Characters The read text string is judged as OK when
10. ZFX C1_ C2 CD Additional Functions Instructions This document describes the additional functions of the ZFX C1_ C2 CD Other functions are the same as those for the ZFX C1_ C2_ Also read the User s Manual 2264 for the ZFX C1_ C2_ Functions original to the ZFX C1_ C2_ CD are as follows Three measurement items Barcode 2D Code Multi Colors Auto functions Inspection by Individual Application Barcode This function reads and verifies barcodes Read results and verification results can also be output Measurement items to be executed from this measurement item onwards can also be specified according to the verification results This allows you to specify a measurement flow matched to the code type Nine barcode types can be read JAN EAN UPC Code39 Codabar NW 7 ITF Interleaved 2 of 5 Code 93 Code128 GS1 128 GS1 DataBar Truncated Stacked Omni directional Stacked Omni directional Limited Expanded Expanded Stacked Pharmacode GS1 128 Composite Code CC A CC B CC C GS1 DataBar was formerly known as RSS Setup Measurement Draw the measurement region then execute One barcode is read in a single measurement region AUTO setting The barcode type and some of the When the measurement region contains multiple decode conditions are automatically set barcodes the result of the first barcode to be read is output Measurement region APY orl on tf mMmportant Reading will end in error if the barcode t
11. d digit positions Up to 32 characters can be set as the number of digits Example First compared digit 2 last compared digit 6 OMIRIOIN 2 0 0 8 2nd digit 6th digit The text string used for verification becomes MRON2 Output characters OFF default value ON Sets whether or not to output the read results on the serial interface Error string Partial output Max 20 digits default value NG OFF default value ON Sets the text string to be output when a read error occurs _ _JASCII code table p 3 Sets whether or not to specify a range in the read data to output from when Output characters is set to ON Output digit 1 to 1024 default value first digit 1 last digit 1 Sets the first and last digit positions to output If the read text string contains non targeted digits the error string is output Measurement control OFF ON default value Sets whether or not to control the next measurement item to be executed based on the verification results ZFX C1_ C2_ CD Additional Functions Instructions Output function of the read results eThe output order The read results can be output on the serial interface When the calculation results are output at the same time the calculation results are output first followed by the read results text string Code conversion The following character codes need to be converted for output The texts after conversion are output
12. er Range 52 Verification func 0 OFF 1 ON 53 Verified master data 0 All master data 1 Master0 2 Master1 3 Master2 32 Master31 54 Partial verification 0 OFF 1 ON 55 Last compared digit 1 to 1024 56 First compared digit 1 to 1024 57 Output characters 0 OFF 1 ON 59 Error string 1 to 20 characters 60 Partial output 0 OFF 1 ON 61 Last output digit 1 to 1024 62 First output digit 1 to 1024 63 Measurement control 0 OFF 1 ON 64 Code type 0 JAN EAN UPC 1 Code39 2 Codabar 3 ITF 4 Code93 5 Code128 GS1 128 6 GS1 DataBar 7 Pharmacode 65 Timeout time ms 1 to 9999 66 Check digit 0 OFF 1 ON 67 Composite component 0 OFF 1 ON 68 Direction Pharma 0 Horizontal mode 1 Vertical mode 69 Reverse decode Pharma 0 OFF 1 ON 71 Num of characters upper limit value 1 to 1024 72 Num of characters lower limit value 1 to 1024 74 Characters threshold 1 to 32 characters 155 N Master data for master data N 1 to 10 characters excluding NULL 187 N Verified master data for master data N 1 to 32 characters 219 N First meas Item No for master data N 1 to 127 ZFX C1_ CD 1 to 31 251 N Last meas Item No for master data N 1 to 127 ZFX C1_ CD 1 to 31 ZFX C1_ C2_ CD Additional Functions Instructions 17 18 2D Codes Data No Parameter Range 52 Verification func 0 OFF 1 ON 53 Verified master data 0 All master data 1 Master0 2 Master1 3 Master2 32
13. he calibration function When AUTO setting is executed the value obtained by incrementing decrementing this value on the measured value is set as the thresholds Area judgment 0 to 9999999 999 Possible output results Sets the area value to be judged as the effective color When AUTO setting is executed only up to four colors having an area within these upper and lower limit values are automatically registered The following values can be output when expressions are set Item Judgment result JG Description The judgment result is output 0 OK 1 NG 2 not measured Area 1 to 4 AR1 to 4 Ref area 1 to 4 SA1 to 4 Diff area 1 to 4 DA1 to 4 a The area of the measurement color is output 0 to 9999999 999 The area when the measurement region is set is output 0 to 9999999 999 The area difference obtained by measurement value reference value is output 9999999 999 to 9999999 999 ZFX C1_ C2_ CD Additional Functions Instructions 13 14 Auto functions AUTO button RUN mode In the RUN mode all measurement items can be batch set automatically by pressing the AUTO button AUTO setting content differs with each measurement item For details see AUTO Setting in Chapter 7 of the ZFX User s Manual gt MENU mode System Operation AUTO Button RUN mode Setup Item Description ON In the RUN mode when the AUTO button is pressed automatic setting of all
14. istered Manual setting Text string up to 32 characters long can be registered as master data via the software keyboard 2 byte characters 1 byte kana characters and control codes cannot be entered Check available characters in the ASCII table The following characters can be used as wildcards Wildcard for zero or more characters Wildcard for one character J ASCII code table p 3 This is the text string displayed as the verification result on the result display screen First meas Item No This is the Start No of measurement items to be executed when the measurement control is set to ON and the read text string match the master data Last meas Item No This is the End No of measurement items to be executed when the measurement control is set to ON and the read text string match the master data LT Measurement control p 5 When the manual registration screen is displayed after execution of AUTO setting unavailable characters in manual registration control codes 2 byte characters 1 byte kana characters etc are displayed as ZFX C1_ C2_ CD Additional Functions Instructions Threshold This function sets the judgment conditions gt MENU mode Setup Item Limits Item Num of characters Characters Description Sets the range of number of characters to be judged as OK Range 0 to 1024 The read text string is judged as OK when it is the same as the characters in this me
15. nu Up to 32 characters can be set Check available characters in the ASCII table 2 byte characters 1 byte kana characters and control codes cannot be entered The following characters can be used as wildcards Wildcard for zero or more characters Wildcard for one character LJ ASCII code table p 3 Image adjustment if necessary The following items can be changed and set to the image of the measurement target gt MENU mode Setup Item Img Adj Item Select Camera Color filter Filtering BGS level Description For details refer to Chapter 3 Image Adjustment of the ZFX User s Manual ZFX C1_ C2_ CD Additional Functions Instructions 10 Operation mode details if necessary Set items below as required gt MENU mode Setup Item Detail Function condition Setup Item Verification func Setting Value OFF default value ON Description When set to ON verification with the master data is executed Verified master data All master data default value Master data 0 to 31 Selects the model to be used for verification Partial verification Compared digit Output characters OFF default value ON 1 to 1024 default value first digit 1 last digit 1 OFF default value ON The number of digits in the read results to be verified with the master data can be limited When Partial verification is set to ON set the first and la
16. s including control codes that are read are displayed as spaces The read string is displayed up to 32 characters When more than 32 characters are read is displayed at the end of the string ZFX C1_ C2_ CD Additional Functions Instructions 11 12 Size Inspection Multi Colors This function measures the areas of up to four colors simultaneously which enables to measure the difference of color pattern Each of the area values and differences with reference values can be output This function cannot be used when a monochrome camera is connected Setup Measurement Measurement region and up to four reference The area of each color is measured and if even one of the colors can be registered area values is judged as NG the overall judgment result is NG a en ee __ Measurement region Area of color 1 Color 1 Area of color 2 Color 2 Color 3 Area of color 3 Image adjustment This function picks up the color to be measured gt MENU mode Setup Item Img Adj Item Description Select Camera For details refer to Chapter 3 Image Adjustment of the ZFX User s Manual Color pickup Region settings This function sets the measurement region gt MENU mode Setup Item Region Item Description Measurement region Sets the region to be measured Reference registration When the measurement region is set measurement is executed on the display image and the result of e
17. st compared digit positions Up to 32 characters can be set as the number of digits Example First compared digit 2 last compared digit 6 OIM R O N 2 0 0 8 2nd digit 6th digit The text string used for verification becomes MRON2 Sets whether or not to output the read results on the serial interface Error string Partial output Output digit Measurement control Max 20 digits default value NG OFF default value ON 1 to 1024 default value first digit 1 last digit 1 OFF default value ON LT Output function of the read results p 5 Measurement control function p 5 Sets the text string to be output when a read error occurs _ _ ASCII code table p 3 Sets whether or not to specify a range in the read data to output from when Output characters is set to ON Sets the first and last digit positions to output If the read text string contains non targeted digits the error string is output Sets whether or not to control the next measurement item to be executed based on the verification results ZFX C1_ C2_ CD Additional Functions Instructions Decode condition detailed settings Be Sure to set the detailed conditions for the code type Set other items as required By AUTO setting Code type Mirror Code color Shape Data Matrix are set automatically gt MENU mode Setup Item Detail Decode condition Setup Item Code type Timeout Mirror Code color
18. ue 0 000 to 9999999 999 72 Individual area1 lower limit value 0 000 to 9999999 999 73 Individual area2 upper limit value 0 000 to 9999999 999 74 Individual area2 lower limit value 0 000 to 9999999 999 75 Individual area3 upper limit value 0 000 to 9999999 999 76 Individual area3 lower limit value 0 000 to 9999999 999 77 Individual area4 upper limit value 0 000 to 9999999 999 78 Individual area4 lower limit value 0 000 to 9999999 999 ZFX C1_ C2_ CD Additional Functions Instructions MEMO ZFX C1_ C2_ CD Additional Functions Instructions
19. ult of the first 2D code to be read is output Measurement region Reading will end in error if the 2D Code type is incorrectly set Set the code type before starting reading When AUTO setting is executed the captured 2D barcode is read and the following items can be set eCode type p 11 eMirror p 11 eCode color for Data Matrix and PDF417 only p 11 Shape for Data Matrix only p 11 Region settings This function sets the measurement region gt MENU mode Setup Item Region Item Description Measurement region Sets the region to be measured ZFX C1_ C2_ CD Additional Functions Instructions Registering the master data for verification Master data are used for verification After reading process the read text string can be verified against the pre registered master data 32 sets of master data can be registered as text string Also processing to be executed from this measurement item onwards can also be branched according to the verification results when measurement control function is ON gt MENU mode Setup Item Master data Item Masterdata Rename Description There are two modes for registering master data auto setting and manual setting Auto setting The actual code is used to register the master data When the AUTO button is pressed the code is read and the result is registered as the master data Text string up to 32 characters long are registered Control codes also can be reg
20. xecution is registered as the reference value To re register only reference values you can use this function to re register only reference values based on the image currently on screen ZFX C1_ C2_ CD Additional Functions Instructions Threshold This function sets the judgment conditions gt MENU mode Setup Item Limits Setup Item Area 1 to 4 Description Sets the range of the area to be judged as OK Range 0 to 9999999 999 When calibration is OFF the range becomes 0 to 307200 Detailed settings if necessary Adjust the detailed conditions if necessary gt MENU mode Setup Item Detail Setup Item Fill profile Calibration Auto THset Setting Value OFF default value ON OFF default value ON 0 to 9999999 999 Description To measure the outer periphery of the measurement target set this item to ON When this item is set to ON measurement is performed with all of the area between the start point colors outside of measurement target gt measurement target color and the end point measurement target color gt colors outside of measurement target inside the measurement region judged to the measurement target color For details refer to the Area detailed settings in Chapter 3 of the ZFX User s Manual Measurement results are output using the camera s coordinate values Measurement results are output using the coordinate value converted by t
21. ype is incorrectly set Set the barcode type before starting reading When AUTO setting is executed the captured barcode is read and the following items can be set eCode type p 6 eDirection for Pharma only p 6 eReverse decode for Pharma only p 6 ZFX C1_ C2_ CD Additional Functions Instructions Region settings This function sets the measurement region gt MENU mode Setup Item Region Item Description Measurement region Sets the region to be measured Registering the master data for verification Master data are used for verification After reading process the read text string can be verified against the pre registered master data 32 sets of master data can be registered as text string Also processing to be executed from this measurement item onwards can also be branched according to the verification results when measurement control function is ON gt MENU mode Setup Item Master data Item Description Master data There are two modes for registering master data auto setting and manual setting Auto setting The actual barcode is used to register the master data When the AUTO button is pressed the barcode is read and the result is registered as the master data Text string up to 32 characters long are registered Control codes also can be registered Manual setting Text string up to 32 characters long can be registered as master data via the software keyboard Check available characters in

Download Pdf Manuals