AIR-SURE LEAK DETECTOR - Retro

image

Contents

1. DESCRIPTION Primarily intended as a tool to locate leaks in single ply and two ply membrane systems including but not limited to air barriers vapor barriers roofing systems waterproofing and ground liners Can be utilized during construction prescriptive testing and post construction For commercial industrial institutional and residential applications COMPOSITION AND MATERIALS Air Sure Leak Detector body is comprised of powder coated steel The test chamber is durable poly carbonate with a closed cell neoprene rubber seal Material Safety Data Sheets MSDS for the Air Sure Test Solution are available from your local distributor upon request DIMENSIONS Leak Detector body 20 0 in x 6 5 in x 6 5 in 28 0 in x 17 0 in x 17 0 in with Standard Dome Profile attached 14 0 pounds 6 4 kg POWER SUPPLY One 1 12V sealed lead acid gel battery rechargeable ACCESSORIES Air Sure Leak Detector comes complete with Standard Dome Profile 4L Air Sure Test Solution with four 4 250 mL dauber bottles Battery Charger and Operator s Manual 2 TECHNICAL DATA APPLICABLE STANDARDS Test method is in keeping with ASTM E 1186 98 Standard Practices for Air Leakage Site Detection in Building Envelopes and Air Retarder Systems method 4 2 7 Chamber Depressurization in Conjunction with Leak Detection Liquid MATERIAL CONSIDERATIONS Testing using the Air Sure Leak Detector in conjunction with Air Sure Test So
2. fumes or dust Do not place the Leak Detector near fire or extreme heat Use of an attachment not recommended by the distributor may result in a risk of fire electric shock or personal injury 14 Optional Accessories There are a variety of other test chamber profiles that can be used to test specific details and require the hose attachment Each end of the hose fits onto the adapters located on the profile and on the standard dome To use the hose attachment profiles place the Leak Detector on a flat surface such that the standard dome chamber has a continuous seal to the surface Place the hose attachment profile over the test area once Test Solution has been applied to the detail Run the test as normal holding the hose attachment profile over the sample area Contact your local distributor for a list of available profiles or for information on custom profiles 15 Storage and Transportation In order to keep the Air Sure Leak Detector in optimal working condition store the equipment when not in use and use caution when transporting the equipment Follow the guidelines below Storage If you are storing the equipment in the recommended Air Sure Security Case follow the packing instructions on the case to ensure a stable environment for the equipment when not in use If you are not using the Air Sure Security Case store the Leak Detector with the test chamber on the unit The Leak Detector and the Test Solution should b
3. is required Charging Care When using the battery charger adhere to the following safety guidelines DO NOT OPERATE THE LEAK DETECTOR WHILE IT IS BEING CHARGED The Leak Detector should be charged in a location where the temperature is between 10 C 50 F and 40 C 104 F Do not operate the charger outdoors Guard against electrical shock by preventing body contact with grounded surfaces while charging the Leak Detector Do not expose the battery charger to any liquid or frozen liquid An extension cord should not be used in conjunction with the charger Use of an extension cord in this manner could result in fire or electric shock Do not operate the charger with a damaged cord or plug If the cord or plug is damaged have them replaced immediately by a qualified electrician Do not operate the charger if it has received a sharp blow been dropped or otherwise damaged in any way It must be replaced To reduce the risk of electric shock unplug the charger from the power outlet before attempting to perform any maintenance or cleaning Once unplugged the charger may be wiped clean with a clean damp cloth and allowed to dry before used again Battery Use Do not attempt to change the battery or use non Air Sure batteries The Air Sure warrantee does not cover damage caused from using non Air Sure batteries and or battery chargers If the battery is punctured and the battery fluid comes into contact with th
4. on the headlight in the nose cone will be activated The corresponding Light Indicator on the faceplate will illuminate when the Light Switch is activated Note The headlight should be used only to illuminate the test area and is not intended as a replacement for any auxiliary lighting necessary to perform this or any other work Air Sure Test Solution Use only Air Sure Test Solution with the Leak Detector The Air Sure Test Solution has been specially formulated such that it will not have any adverse effects upon single ply waterproofing roofing or air barrier membranes or on the Leak Detector unit Do not use the Air Sure Test Solution on breathable membranes such as building wrap as it will break down the surface tension of moisture on paper causing it to pass through the building wrap Do not use the Air Sure Test Solution to detect oxygen leaks If the Air Sure Test Solution comes into contact with the eyes flush eyes immediately with lukewarm water If irritation persists contact your doctor Before conducting any onsite testing using the Air Sure Test Solution check the expiry date on the shipping bottle to ensure that the Test Solution has not passed its expiry date Even if the expiry date has not been reached ensure that the Test Solution is still functional before using it for onsite testing Conduct a test using the Air Sure Leak Detector and Test Solution on a known leak area to ensure that the Test Solutio
5. present Bubbles may also form and pop quickly A very large leak may not form a bubble but rather blow solution away from the detail This may also be caused by lack of solution on the testing area The movement of the solution in this fashion usually signifies a leak However a retest is advised in this situation When a leak has been identified the test should be halted immediately letting the pressure within the test chamber decrease before removing the machine from the detail The detail can then be marked for further repair or the bubble can be photographed if documentation is required for the particular job 12 If the test procedure is followed correctly with the machine in Auto Mode the unit will automatically shut off when a pressure differential of 500 Pa 2 0 inches of water column is reached Record the test results Note This does not imply that the workmanship of the detail is to the specifications of the particular job nor does it imply that the detail in question will not leak at a higher pressure differential Cleaning the Test Area of Residual Test Solution Although testing has shown that the Test Solution causes no damage to the membrane or metal details it is essential that all residual test solution be removed from all working surfaces once testing has been completed Injury may occur by slipping on a surface that has had solution applied to it Wipe the detail with a clean dry cloth to remove tes
6. the casing and chamber of the Leak Detector with a clean cloth For best results use a furniture polish on the casing NEVER use gasoline other petroleum based products or any solvent for cleaning the Leak detector 17 Retro Specs Limited Warrantee for the United States and Canada What Does this Warrantee Cover Subject to the exclusions contained below Retro Specs Ltd warrants its leak detection equipment to be free from defects in materials and workmanship under normal consumer usage for the period s outlined below This limited warrantee is a consumer s exclusive remedy and applies as follows to new Air Sure Products and Accessories purchased by consumers in the United States or Canada which are accompanied by this written warrantee Products and Accessories Products Covered Length of Coverage Products and Accessories as defined One 1 year from the date of purchase above by the first consumer purchaser pf the product Exclusions Normal Wear and Tear Periodic maintenance repair and replacement of parts due to normal wear and tear are excluded from coverage Batteries Only batteries whose fully charged capacity falls below 80 of their rated capacity and batteries that leak are covered by this limited warrantee Abuse amp Misuse Defects or damage that result from a improper operation storage misuse or abuse accident or neglect such as physical damage cracks scratches etc to the surface of the pr
7. AIR SURE LEAK DETECTOR USER MANUAL Welcome Thank you for purchase of the Air Sure Leak Detector We are pleased that you have selected our equipment for your membrane testing needs Retro Specs Ltd Box 69 Grosse Isle MB ROC 1G0 204 322 5081 rskevinknight gmail com www retrospecslitd com Air Sure and Retro Specs are registered in the US Patent and Trademark Office and the Canadian Intellectual Property Office Retro Specs Ltd 1997 2000 2005 2006 2011 The information contained in Retro Specs Ltd user manuals is believed to be correct at the time of printing Retro Specs Ltd reserves the right to change or modify any information or specifications without notice The contents of Retro Specs Ltd user manuals are provided as is Except as required by applicable law no warrantees of any kind either express or implied including but not limited to the implied warrantees of merchantability and fitness for a particular purpose are made in relation to the accuracy reliability or contents in this manual Caution Changes or modifications made to the Leak Detector that are not expressly approved by Retro Specs Ltd will void the user s authority to operate the equipment Contents Safety and General Information 0 0 0 0 cee eee 4 Introduction to the Air Sure Leak Detection System 0 eee eee 6 Getting Started os oc ey be ib ek Bey ob te ee eit iS bed eee Vest eed ae ee Pe
8. e See eg Eee Ra ee RE RW a Ae SAEC DR i ee eo Bae ees Ee 18 Specifications cortas ut ege agis opes God ped a acs Pain cael e od Sa du a Rae he Melee atacand aon 20 Safety and General Information IMPORTANT INFORMATION ON SAFE AND EFFICIENT OPERATION OF YOUR AIR SURE LEAK DETECTOR DO NOT ATTEMPT TO OPERATE THE LEAK DETECTOR UNTIL YOU HAVE THOROUGHLY READ AND UNDERSTAND ALL OPERATING INSTRUCTIONS AND SAFETY PROCEDURES CONTAINED IN THIS MANUAL FAILURE TO COMPLY WITH THESE OPERATING INSTRUCTIONS AND SAFETY PROCEDURES MAY RESULT IN ACCIDENTS INVOLVING FIRE ELECTRIC SHOCK AND OR SERIOUS PERSONAL INJURY SAVE THIS MANUAL AND REVIEW IT FREQUENTLY FOR CONTINUED SAFE OPERATION General Use Use the Leak Detector for the correct purpose Do not use it for anything other than what it was designed to do Use only Air Sure Test Solution with the Leak Detector Use of an attachment not recommended by the distributor may result in a risk of fire electric shock or personal injury Never use the Leak Detector in an explosive atmosphere Normal sparking of the motor could ignite flammable liquid gases fumes or dust Do not place the Leak Detector near fire or extreme heat Use safety glasses when the Leak Detector is in operation Do not operate the tool when tired or while under the influence of drugs alcohol or medication Keep the work area clean Cluttered or dirty areas that have been improperly cleaned of residual Test Solution are pot
9. e ia 7 What s mthe Box oos ld RD bap een eats deta deat dot bep udo AR arg wig aed oobi ee 7 Gharging the Battery 9 21 2 ag cade tee atra ae deal eap e ua Mae Ag ee eee A A pae dd 8 Battery USE AER TET 8 Getting to Know Your Air Sure Leak Detector 0 0200 cece eee 9 Hardware Components 22 esu dia haere hd tus deba dor Pmt Lue Deed depo eed dd et doa 9 ControliPanel wie dipae os Rap eel Ed PR x uv ba e ra E Ed NE d ait xus gd 10 Air Sure Test Solutiofi see ERRARE LR p eR AR ER MUERE PANIER 11 Using the Air Sure Leak Detector 0 0 ce e 11 Cleaning the Area Around the Detail Being Tested lll lees 12 Applying Test Solution to the Sample Area 00000 ce lh 12 Placing the Leak Detector Over the Detail llle 12 Activating the Leak Detector 2 2 02 ce eR a Ru RR Re ed PA Rud RR 13 Cleaning the Test Area of Residual Test Solution 00 0000 cee ee 14 Optional ACCessorles oisi ke ei eae A Rae ca ie RN E erede RE E 15 Storage and Transportation o oerscsci biert te Saacan at pE he 16 Storage oet poi eat te ca a T e e tacet a e a S eho d qo 5 EE re e E oe tana 16 Hoisting e etes aom Lu idc op Rabe eens e aea eh as 16 Transportation Dy AIP ick dee cs E ERREUR UR AARAU ha Dee Shee I EL MEER 16 Maintenance uos REIR Sac RSG RR eg mb EA pe CECI RR RS EA 17 Maintenance asyr ciii depan AE Vad a UA EAS ee ea PASS CREE FETA 17 Gleaning qx Ole dni Aa ze an Rc Ee Rc RA ode 17 Warrante v o
10. e skin wash the skin immediately with soap and water and seek medical attention If the fluid gets into the eyes flush eyes immediately with lukewarm water for at least ten minutes and seek immediate medical attention Return the defective Leak Detector to an authorized service center or to your local distributor Getting to Know Your Air Sure Leak Detector Hardware Components The test chamber is the clear plastic dome located on the end of the Air Sure Leak Detector The black rubber strip that runs along the bottom of the test chamber is the chamber seal The nose cone is located inside the test chamber and is attached to the Leak Detector body Contained within the nose cone are the pressure switch and the nose cone light To remove or change the test chamber first locate the ring lock which surrounds the nose cone and turn it in a counterclockwise motion Once the ring lock is removed the test chamber simply pulls off Located within the Leak Detector body are the motor the battery and circuitry The control panel is located on the face of the Leak Detector body The trigger switch is found on the handle which is attached to the body Control Panel It is important to be familiarized with the control panel before operating the Air Sure Leak Detector Charger Connection Charging Indicator Battery Power Level Indicator Pressure Indicator Auto Mode Switch and w Indicator Light Switch and Indicator Au
11. e stored in a dry and secure area out of reach of children Hoisting Follow local hoisting and rigging regulations when lifting equipment to the test destination DO NOT lift the equipment by carrying it up an unstable incline ladder or scaffolding Transportation by Air There are no components inside the Leak Detector which restrict transportation by air The following is a list of particulars that will aid you in passage through customs Batteries are sealed lead acid gel Serial number is located on the side of the machine body Country of origin is located on the control panel The weight of the Leak Detector is approximately 15 pounds 6 8 kg 16 Maintenance Maintenance Check damaged parts Discontinue using the Leak Detector if any part of the unit appears damaged Refrain from further use until the unit is properly repaired or replaced at an authorized service center Never open or disassemble the Leak Detector Some parts of the Air Sure Leak Detector may be serviced without bringing the unit to the distributor s service depot Burned out light bulb in the nose cone replace with a 6 3V 0 15A size T 374 incandescent light bulb Unscrew the lens cover counterclockwise to remove Once the lens cover has been removed unscrew light bulb counterclockwise Replace bulb Screw lens cover clockwise back onto the Leak Detector For problems that are not listed above contact your local distributor Cleaning Wipe
12. ential hazards Avoid dangerous environments Do not work on wet and or slippery surfaces Do not carry the Leak Detector up steep inclines or ladders Follow the proper hoisting guidelines for your area Do not overreach Keep proper footing and balance at all times Do not use the Leak Detector while on a ladder or on unstable support Storage and Maintenance Store the Leak Detector and Test Solution in a dry and secure area out of reach of children Keep the handle and the body of the Leak Detector dry clean and free from oil and grease Always use a clean cloth when wiping the Leak Detector Never use brake fluids gasoline petroleum based products or any strong solvents for cleaning Never open or disassemble the Leak Detector Check damaged parts Discontinue using the Leak Detector if any part of the unit appears damaged Refrain from further use until the unit is properly repaired or replaced at an authorized Service center Air Sure Test Solution Do not use the Air Sure Test Solution to detect oxygen or other gas leaks Do not use the Air Sure Test Solution on breathable membranes such as building wrap If the Air Sure Test Solution comes into contact with the eyes flush eyes immediately with lukewarm water If irritation persists contact your doctor Battery and Charging Do not operate the Leak Detector while it is being charged Use only the battery charger provided with the Leak Detecto
13. lution will not damage the membrane system when the equipment is used as intended Air Sure Test Solution should not be applied to plastic resin building wraps 3 USE PREPARATORY WORK The sample area selected should be wiped clean of dirt grit dust or debris Test area should not be hot from torching frosted extremely wet and should be free of ice Testing can be performed on seams joints and penetrations in the membrane 20 METHOD Air Sure Test Solution is applied liberally to the area being tested The test chamber is placed over the sample area and the Leak Detector activated Contact between the Test Solution and test chamber should be avoided Bubbles in the Test Solution indicate the presence of a possible leak 4 AVAILABILITY AND COST AVAILABILITY Air Sure Leak Detector is available worldwide usually shipped from stock Contact Retro Specs Ltd for a list of distributors COST Current price list available from local distributor 5 WARRANTEE The information contained herein is the best available relating to the Air Sure Leak Detector and the recommendations contained herein are based upon information believed to be reliable Limited warrantee covers all parts and labor costs resulting from defects in materials or workmanship for a period of one 1 year 6 MAINTENANCE CLEANING Test chamber and machine casing should be wiped clean with a damp cloth Furniture polish may be used on the machine casi
14. m please contact your local distributor Getting Started What s in the Box Your Air Sure Leak Detector comes equipped with a battery already installed battery charger Air Sure Test Solution and four bottles with daubers You can purchase other accessory items and profiles for maximum performance To purchase other Air Sure Leak Detector accessories and profiles contact your local Air Sure distributor Charging the Battery New machines are shipped with batteries partially charged Before using your Air Sure Leak Detector you should charge the battery using the following instructions 1 Plug the battery charger into the Leak Detector The socket is located on the face of the control panel 2 Plug the other end of the charger into the appropriate electrical outlet 3 A full recharge can be achieved in approximately three 3 hours Although the built in circuitry will prevent overcharging it is recommended that the charger be disconnected after this time To reduce the risk of damage to the charger cord pull it by the plug when disconnecting the charger Do not step on the cord or subject it to damage or stress Disconnect the charger from the power supply when not in use As the batteries are sealed lead acid gel batteries they are not subject to the effects of memory and may be charged within any level of charge remaining The Air Sure Leak Detector is designed to achieve approximately 130 tests before recharging
15. n still oubbles see Using the Air Sure Leak Detector 10 Using the Air Sure Leak Detector There are five steps in correctly performing a test with the Air Sure Leak Detector 1 Clean the area around the detail being tested 2 Apply Test Solution to the sample area 3 Place the Leak Detector over the detail 4 Activate the Leak Detector 5 Clean the test area of residual Test Solution Cleaning the Area Around the Detail Being Tested Ensure that the test area is free of dirt dust and debris The test area should not be hot from torching frosted or extremely wet slight dampness around the test area will not compromise the results of the test The area being tested should be free of ice which may act to plug the leak Applying Test Solution to the Sample Area Apply the Test Solution to the sample area using the dauber included with the 250 ml bottles When applying the Test Solution ensure the entire sample area is covered with a wet film of solution In the case of a penetration ensure the entire area is covered In the case of a seam or joint ensure that there is solution pushed into the seam or joint Do not overapply Test Solution the Test Solution has been overapplied if the Test Solution has formed a froth or foam over the sample area instead of a thin film The Air Sure Test Solution is specially designed to cling to membranes and metal details However testing of the detail should be conducted immedia
16. ng Do not use gasoline petroleum based products or solvents on the Air Sure Leak Detector CHARGING Air Sure Leak Detector is designed to perform approximately 100 tests before recharging if the battery is required A full recharge can be achieved in approximately three 3 hours Although the built in circuitry will prevent overcharging it is recommended that the charger be disconnected after this time LIGHT BULB Nose cone light bulb is a 6 3V 0 15 size T 374 incandescent light bulb 7 TECHNICAL SERVICES Technical support is available from Retro Specs Ltd Call 204 322 5081 Specification assistance Site advice and recommendations 8 RELATED REFERENCES ASTM E 1186 02 PWGSC National Master Specification Section 07271 Air Barriers Descriptive Proprietary Section 07272 Air Barriers Performance Canada Mortgage and Housing Corporation Guidelines for Delivering Effective Air Barrier Systems ASTM STP 1422 A New Protocol for the Inspection and Testing of Building Envelope Air Barrier Systems 21
17. oduct resulting from misuse b contact with liquid water rain extreme humidity or heavy perspiration sand dirt or the like extreme heat or food c use of the Products or Accessories for commercial purposes or subjecting the Product or Accessory to abnormal usage or conditions or d other acts which are not the fault of Retro Specs are excluded from coverage Use of Non Air Sure Products and Accessories Defects or damages that result from the use of Non Air Sure branded or certified Products Accessories Electronics or other peripheral equipment are excluded from coverage Unauthorized Service or Modification Defects or damages resulting from service testing adjusting installation maintenance alteration or modification in any way by someone other than Retro Specs or its authorized service centers are excluded from coverage Altered Products Products or Accessories with a serial numbers or date tags that have been removed altered or obliterated b broken seals or that show evidence of tampering c mismatched board serial numbers or d nonconforming or non Air Sure housings or parts are excluded from coverage Who is Covered This warrantee extends only to the first consumer purchaser and is not transferrable 18 What Will Retro Specs do Retro Specs at its option will at no charge repair replace or refund the purchase price of any Products or Accessories that does not conform to this warrantee We may
18. r Use of another charger may damage the unit may cause serious injury and will void the warranty The charger was provided for use only with this Leak Detector To reduce the risk of injury do not charge any other batteries or any other piece of equipment with this battery charger Guard against electrical shock by preventing body contact with grounded surfaces while charging the Leak Detector To reduce the risk of electric shock unplug the charger from the power outlet before attempting to perform any maintenance or cleaning Once unplugged the charger may be wiped clean with a clean damp cloth and allowed to dry before used again If the battery is punctured and the battery fluid comes into contact with the skin wash the skin immediately with soap and water and seek medical attention If the fluid gets into the eyes flush eyes immediately with lukewarm water for at least ten minutes and seek immediate medical attention Return the damaged Leak Detector to an authorized service center or to your local distributor Do not expose the battery charger to any liquid or frozen liquid To reduce the risk of damage to the charger cord pull it by the plug when disconnecting the charger Do not step on the cord or subject it to damage or stress An extension cord should not be used in conjunction with the charger Use of an extension cord in this manner could result in fire or electric shock Do not operate the charger
19. t solution Wash area with water and wipe dry Check the surface by running your hand along the test area If the test area is slippery to the touch then repeat the cleaning procedure until the surface is no longer slippery It is the responsibility of the tester to remove all residual Test Solution Note Prior to using the Air Sure Test Solution ensure that the Test Solution has not passed its expiry date and is functioning as intended The solution should be tested on a known leak if the solution does not bubble it has expired 13 Notes on Using the Air Sure Leak Detector When using the Air Sure Leak Detector always adhere to the following safety guidelines When using the Leak Detector ensure that the pressure reference port located on the nose cone exterior remains uncovered throughout testing Be careful not to cover the port with your finger when running the machine Use the Leak Detector for the correct purpose Do not use it for anything other than what it was designed to do Always employ appropriate safety measures while using the Leak Detector use safety glasses when the Leak Detector is in operation do not operate the Leak Detector when tired or while under the influence of drugs alcohol or medication and do not use the Leak Detector while on a ladder or on unstable support Never use the Leak Detector in an explosive atmosphere Normal sparking of the motor could ignite flammable liquid gases
20. tely after application of the solution in order to achieve optimum results Take care not to spill the Test Solution Secure the cap back onto the dauber bottle when not in use to avoid spilling Test Solution 11 Placing the Leak Detector Over the Detail Center the chamber over the detail holding the unit firmly against the membrane When the seal is in continuous contact with the substrate the machine is ready for activation It is not absolutely necessary to achieve a perfect seal between the test chamber and the membrane as the machine will adjust for any extraneous leakage that may occur When placing the chamber over the detail avoid contact between the Test Solution and the chamber seal If there is solution under the seal bubbles may form at the seal producing a false test result If this occurs a retest should be performed in order to achieve optimum test results Activating the Leak Detector Once the chamber has been correctly placed over the test area the machine is ready for activation Begin the test by pulling and holding down the trigger switch located on the handle The test can be stopped whenever necessary by releasing the trigger switch When the test is run if the solution around the test area bubbles a leak is present If the solution does not bubble the detail is airtight Careful observation is important as bubbles of different e sizes can form anywhere within the test area where solution is
21. to Mode Switch and Indicator When the Auto Mode switch is engaged the pressure differential created by the Leak Detector can increase to a maximum of 500 Pa When the Auto Mode switch is disengaged the pressure differential created by the Leak Detector can increase to a maximum of approximately 2 500 Pa When the Auto mode Indicator is lit the Auto mode switch is engaged Note Auto Mode on is the default setting on the Leak Detector Pressure Indicator The pressure sensor within the main body of the Leak Detector is set to approximately 500 Pa 2 0 water When the pressure differential across the test chamber reaches this level the Leak Detector will sound an alarm the Pressure Indicator light will illuminate and the unit will automatically shut off indicating the completion of the test provided the Auto mode switch is the default on position Battery Power Level Indicator The Battery Power Level Indicator light will remain lit when the battery is at the required level for operation As the battery begins to wear down the Battery Power Indicator light will flash indicating that the battery requires recharging As the battery continues to decrease in energy the light will begin flashing more slowly Charging Indicator The Charging Indicator will become illuminated when the battery charger is plugged into the Leak Detector and the battery is receiving a charge Light Switch and Indicator When the Light Switch is turned
22. use functionally equivalent reconditioned refurbished pre owned or new Products or Accessories How to Obtain Warrantee Service or Other Information Contact your local distributor You will receive information on how to ship the Products or Accessories at your expense to an Air Sure authorized repair center To obtain service you must include a a copy of your receipt bill of sale or other comparable proof of purchase b a written description of the problem and c your address and telephone number What Other Limitations Are There ANY IMPLIES WARRANTEES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTEES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED TO THE DURATION OF THIS WARRANTEE OTHERWISE THE REPAIR REPLACEMENT OR REFUND AS PROVIDED UNDER THIS EXPRESS LIMITED WARRANTEE IS THE EXCLUSIVE REMEDY OF THE CONSUMER AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTEES EXPRESS OR IMPLIED IN NO EVENT SHALL RETRO SPECS BE LIABLE WHETHER IN CONTRACT OR TORT INCLUDING NEGLIGENCE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT OR ACCESSORY OR FOR ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND OR LOSS OF REVENUE OR PROFITS LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE ABILITY OR INABILITY TO USE THE PRODUCTS OR ACCESSORIES TO THE FULL EXTENT THESE DAMAGES MAY BE DISCLAIMED BY LAW 19 Air Sure Leak Detector Specifications 1 GENERAL
23. with a damaged cord or plug If the cord or plug is damaged have them replaced immediately by a qualified electrician Do not operate the charger if it has received a sharp blow been dropped or otherwise damaged in any way It must be replaced Do not operate the charger outdoors Disconnect the charger from the power supply when not in use Introduction to the Air Sure Leak Detection System The Air Sure Leak Detection System is an effective efficient and affordable testing system designed to find leaks in single and two ply membranes used in all applications When used in conjunction with visual inspection it provides an accurate reflection of the quality of installation of the membrane and will assist in determining whether the completed system is in adherence with installation specifications and building codes When a test is performed the Air Sure Leak Detector will indicate whether there are leaks in the test sample It is a simple pass fail test Areas where the membrane has been penetrated or damaged fasteners and masonry ties or where membrane continuity has been compromised seams and joints are just some of the details which can be tested using the Leak Detector The Air Sure Leak Detector allows for the testing of the quality of workmanship quickly efficiently and on the job site with little or no disruption to the critical path of construction If you have any questions regarding the Air Sure Leak Detection Syste