Home

FBs-CMGSM, B1-CMGSM User`s Manual

image

Contents

1. space and T SendUserData characters H and E D3825 0x4320 SendUserData characters space and C D3827 0x504D_ SendUserData characters M and P SendUserData characters I and O SendUserData characters N and S SendUserData characters and end of string SendFlag send command Description SendDestAddress characters 1 and 2 4 1 2 Receiving aSMS Incoming SMS messages are saved into registers of PLC in Recv Record standard base D3700 Structure of the record is in following table Description 0x0000 Idle written by PLC program 0x0001 Message received written by CMGSM Registers Caption Phone number of the message sender ees RecvOrigAddress originator Length 20 characters message Length 160 D3720 D3799 RecvUserData Text of the characters This range of registers cannot be used for any other purposes Page 2 of 7 How CMGSM stores a received message START Message received 0x0000 WRITE Phone number INTO D3710 D3719 WRITE Text of SMS INTO D3720 D3799 WRITE 0x0001 INTO D3700 Every register of Phone number or Text contains two characters String of characters ends with special character 0x00 Examples String with one character A D3720 0x0041 String TEXT D3720 0x4554 D3721 0x5458 D3722 0x0000 String HELLO D3720 0
2. One digital input IN and one digital output OUT Device status is indicated with blue GSM LED on the CMGSM front panel Valid statuses are as follows Local Time and Date NITZ from GSM network if available Term Description USB port for module monitoring for service purposes only Firmware update via GSM available Device is not registered to the GSM network Li Ion backup accumulator min 2 days of operation w o charging 500 ms on This state occurs after start of device for approx 30 seconds Lowest level super watchdog function Hardware Power OFF 500 ms off If it remains check SIM card is inserted is active FBs CMGSM can be used directly with PLC FBs xxMC Port 3 Antenna is connected B1 CMGSM can be used directly with PLC B1 xxM Port 1 e SMS functionality is fully under PLC program control 10 ms on Device is registered to the GSM network and is idle r Configuration of CMGSM means just to set several PLC registers 4 s off It means that no GPRS nor CSD connection is active No PLC program support is necessary for CSD and GPRS operation omeen LEDs for indication of the CMGSM status and data flow signalization GPRS active data transfer in progress Unlimited number of logical and analog inputs and outputs can work 10 ms on REF with one CMGSM PLC network CSD data connection in progress Expressed line is common operating state 3 4 Front Panel 1 GSM antenna connector 2
3. 1 12 D3807 year 0 99 D3808 day in week 0 6 X Cancel D3809 hour MSB minute LSB This range of registers cannot be used for any other purposes Step 3 Enter configuration string CMGSM3 PIN 7608 ACODE 998877 into field ASCII Editor and D Notation D3500 x means x th bit of D3500 register For example D3500 0 is the click on button Output Preview Warning Change PIN according your least significant bit in register D3500 Another example D3500 8 15 are eight most real SIM card Significant bits in register D3500 high byte Base of Diag Record D3500 may be changed to another D or R register via configuration key REGDIAG D3801 D3809 ModemTime 2 ModemTime is available in CMGSM with sw version 2 03 and higher 3 CMGSM reads out the local Time and date NITZ from the GSM network if NITZ is available depends on the GMS operator and approx 1 per 10 seconds sends this information do PLC registers The format of ModemTime is similar to PLC registers in RTC Calendar FBs CMGSM User s Manual EN v3 07 doc Page 4 of 7 ES WinProLadder Ladder Diagram Main_unit1 File Edit View Project Ladder PLC Tool Window Help 4 ASCII Table cfg a T Ea Import Teti ExportText E Calculator C Setup s Output Preview ASCII Editor CMGSM3 PIN 7608 APN internet SERVERs test server com PORT 5700 ACODE Doe a Be ono wea el ek es ee es fe ee ea eee he RS232 FBs 1 4MC System Confi
4. Communication module GPRS connection cannot be established 1 check power supply 2 check communication with PLC Fatek 3 check configuration 4 check if it is possible from another computer connected to the Internet to connect to your server may be firewall is wrong configured GPRS connection is not working during CSD connection This is the feature of GSM module GPRS connection is restored automatically after CSD connection is finished Communication is OK but real outputs YO Y3 do not reflect commands 1 PLC FATEK must be in Run mode Use WinProladder to run PLC Communication is OK but inputs X1 X3 do not show correct value 1 PLC FATEK must be in Run mode Use WinProladder to run the PLC Some parameters in the FATEK configuration are not functioning Please check if there is no character before these parameters e g CMGSM3 PIN 7608 ACODE 998877 because CMGSM reads the configuration till the first character FBs CMGSM User s Manual EN v3 07 doc 10 Warranty General warranty period is 12 months after purchase when eventual malfunction device will be repaired free of charge in SEA company while shipping to SEA is paid by customer and SEA pays for shipping back to customer For SW there is 24 months warranty under following conditions Both CPU and PC software is sold as is The software was created by the best software engineers in SEA and was carefully tested both in SEA and al
5. IO connector 3 SIM card holder 4 USB connector 5 DIN rail holder 6 FUNC button 7 Indication LEDs RCV SEND SMS 8 Flat cable for connection to PLC 9 Indication LEDs GSM ERR Element Description GSM Antenna connector see the previous table IN input OUT output Button Multifunction Button DOUT2 change RESTART STAND BY mode Holder it from holder 2 Content of the Delivery USB for connection to PC for debugging purposes only 1 pc of FAC FBS CMGSM or FAC B1 CMGSM LED yellow Receiving SMS from GSM 1 pc of antenna GSM ANT05S LED green Sending SMS to GSM 1 pc of 6 pin connector pitch 3 81 mm rs eee 1 pc of CD with documentation USB E SND FUNC m FBs CMGSM COMMUNICATION GSM MODULE 3 4 1 Pushbutton FUNC Pushbutton FUNC has several functions Short press changes the state of the output OUT DOUT2 Long press longer than 3 seconds will either RESTART CMGSM if CMGSM is powered by the PLC or enter the STAND BY MODE if the CMGSM is powered from the internal accumulator PLC is either disconnected or turned off FBs CMGSM User s Manual EN v3 07 doc Page 1 of 7 3 4 2 IO Connector IO connector has 6 terminals Terminals are designed to supply the input IN of internal Li ION battery Terminals IN IN1 are for digital input Terminals OUT DOUT2 are for digital output CMGSM Please see
6. REGSEND D1000 Begin of the Send Record default Access code for SMS control is 1234 5 5 3 Only CSD without GPRS Configuration string Translated for human this string says CMGSM3 It is configuration for CMGSM default Access code for SMS control is 1234 5 5 4 SIM without PIN GPRS connection Configuration string CMGSM3 APN internet SERVER test server com PORT 5700 AC ODE 998877 Translated for human this string says CMGSM3 It is configuration for CMGSM APN internet Access Point APN is internet SERVER test server com Connect to test server com PORT 5700 Use TCP connection to port 5700 ACODE 998877 Access code for SMS control is 998877 FBs CMGSM User s Manual EN v3 07 doc 6 Usage scenarios for SMS Usage examples can be found on CD with documentation or on the web pages http fatek seapraha cz In category FAC CMGSM are examples of programs for receiving and sending of SMS from PLC 7 Usage Scenarios for GPRS 7 1 Explanation of Important Terms Description The way how to transfer data through the GSM network It is charged according to transferred bytes and not per minutes and is much more suitable for remote monitoring than data connection CSD It is protocol which is used while communicating through GPRS TCP IP Like Fatek protocol is used to communicate between computer and Fatek PLC It is one of protocols in TCP IP
7. case CMGSM3 PIN 7608 APN internet SERVER test server com PORT 5700 ACODE sensitive values are case sensitive Maximum length of configuration string is 200 characters At the end of each part MUST be character semicolon after last pair MAY be character semicolon and MUST be character dolar Part CMGSM3 at the beginning of the string is mandatory It is a stamp of validity Allow 196 words Auto Used 38 words Position D3900 D3937 5 f 2 Basic pa ra mete rs Output Preview Key Description Default PIN code for SIM card It may be omitted if the SIM card does not need a PIN code But it is mandatory if lt empty gt the SIM card needs the PIN code Access code for SMS control You can send SMS message in order to control CMGSM These SMS must begin with this ACODE They will be ignored otherwise Optional Phone number where to send SMS about important MASTER events Connection to PLC failure No SMS are sent if lt empty gt value is empty Only one master is possible x Cancel Step 5 GPRS Configuration string is now black Click OK FBs CMGSM User s Manual EN v3 07 doc Page 5 of 7 5 3 Advanced parameters Default Description First register of the Send Record It is area where PLC writes messages to send See 4 1 1 Sending a D3800 SMS Only D or R registers can be used First register of the Recv Record It is an area where CMGSM writes received messag
8. home network a ORG 2 not registered searching Oe E mo 3 registration denied cee Re Be Be a SR 5 registered roaming De ee ey ee ee ge te ee le ete I tel eee Signal quality in percent 0 100 or 255 if D3501 8 15 DiagSigErr Signal BER 0 7 or 255 if unknown BER 0 7 or 255 if unknown oral ia CMGSM writes value 0x0001 whenever amp ae Edit diagnostic record is refreshed cca 6 inen ascua DiaqAlive seconds This is intended for PLC program a Link TEA delete Tabie g to check if CMGSM is alive In this case PLC Bi Seve TY ervo Program Table program will write a 0x0000 into this a General Purpose Link Table register and wait for 0x0001 here i3 Register Table Version of CMGSM3 in high byte is high fx ModBus Master Table ROOF DiagVersion version number in low byte is low byte is Comment B H low version number os E Overwrite NOR 1 C 1 D3504 0x0000 oae If PLC writes value OxF3A5 to this register Step 1 Right click on Table edit ASCII Table aa the CMGSM will make reset of itself and select New ASCII Table 0x0000 Idle Table Edit 0x0001 Execute command in TANS eToRenise DiagAtCmd written by program in PLC Table Type 0x0003 Command is about to execute Table Name io 2 St lt C C SS S DiagAtFlag written by CMGSM Table starting address D3900 0x0000 Command executed successfully written by CMGSM 0x0004 Exception while executing the Tebe Cepet o Bree loeien com
9. the technical GSM PWR1 2 specifications for details or _ GSM PWRI1 Q 4V 50 onm an el MAX wy Z7 il 1k tal L 35Vac 70MA O 50 Vpc 1 00mA l INPUT O O e g button or mg contact Q OUTPUT e g relay GSM RELE OUT1 4 Function of the device 4 1 sMs One of the primary functions of the CMGSM is to send and receive SMS messages There are 2 kinds of SMS which have different functions and purposes SMS for and from PLC FATEK see chapters 4 1 1 and 4 1 2 r Service SMS commands processed by CMGSM see chapter 4 3 Outgoing SMS from PLC FATEK are sent by PLC program that writes the text and destination phone number into PLC registers and orders CMGSM to send the message by write special value to another register SendFlag CMGSM sends SMS and writes result of the sending to PLC register SendFiag Incoming messages for PLC FATEK are received by CMGSM and the text and origin phone number are written into PLC registers Subsequently in another register RecvFlag is written value that signalizes new received SMS PLC program analyzes the registers and deactivates flag RecvFlag All the SMS structure and security features must be done by PLC program including confirmation that SMS was received if required SMS messages which contains characters hash and exclamation followed by access code are sent and received by CMGSM itself and their function structure and security features cannot
10. FBs CMGSM B1 CMGSM 3 Typical Application Installation User s Manual ten Antenna 1 Introduction Note FATEK PLC is not part of the delivery of this product It is needed to order FBs CMGSM and B1 CMGSM CMGSM for short are communication modules for independently FATEK PLC systems FBs xxMC and B1 xxM CMGSM uses the GSM network to transfer the data CMGSM is based on the quad band GSM module 850 900 1800 1900 MHz CMGSM is backed up by Li Ion accumulator CMGSM offer three different ways of communication with connected PLC The first one is monitoring and remote control of PLC via SMS CMGSM reads periodically PLC registers containing a flag to send SMS if the flag is set CMGSM reads destination phone number and string of characters text sends SMS and clears the flag If there is a SMS received by CMGSM it is written into PLC registers including another flag SMS received to be processed by PLC program At the end the PLC program clears this flag So these operational SMS must be processed by PLC program both on SMS reception and SMS sending Some status and event SMS are predefined in CMGSM e g Connection to PLC failure and only the destination phone number have to be set in PLC registers The second way of communication with PLC via CMGSM is dial up data transfer s via GSM network CSD The connection can be only incoming for CMGSM that 3 1 Configuration may be initiated from a control center for the purpose o
11. M and PLC is lost or IN1 activated L Import Tet ExportText E Calculator C setup S Output Preview gt H when digital input IN IN1 is activated respectively IN1 released ASCII Editor H gt L when digital input IN IN1 is deactivated CMGSM3 PIN 608 ACODE 9968 7 Step 4 Select Non Output Format and click OK 4 ASCII Table cfg j Example of configuration string for GPRS CMGSM3 PIN 7608 APN internet SERVER test server com PORT 5700 ACODE 998877 Allow 196 words Auto Used 15 words Position D3900 D3914 This string means Output Preview CMGSM3 It is configuration for CMGSM PIN 7608 User PIN code of 7608 for SIM card in order to register into the network APN internet Access Point APN is needed in order to use GPRS service in GSM network In this example APN is internet SERVER test server com It is a name of a server to which CMGSM will connect Using TCP connection _ Cancel PORT 5700 Use TCP connection to port 5700 ACODE 998877 Access code for SMS control is 998877 Step 5 Configuration string is now black Click OK General format of these messages is following V TAPEET an Era eT nee aeaii 5 a EE Eal Lale ea PA A Setupte i ola Acceptable keys are shown in table below Unknown keys are ignored no spaces ASCI Editor are allowed inside keys or values Order of pairs is not important Keys are not
12. Place of issue Praha Name Ing Mario Vejlupek Date of issue 7 8 2014 Grade Technical director d i Page 7 of 7
13. be changed by user or PLC program Incoming SMS of this kind are described in chapter 4 3 Service SMS Commands and are used to get information about CMGSM status to reset CMGSM or to get current CMGSM configuration Outgoing SMS of this kind are described in chapter 4 5 Events Events it is information about emergency status of CMGSM module like lost communication with PLC These events are sent to a predefined phone number Master in configuration 4 1 1 Sending a SMS CMGSM periodically tests the first register of the Send Record standard base is D3800 The Send Record is an area in PLC registers which must be filled by program in PLC in order to send a SMS message For structure of the record see the following table Registers Caption Description 0x0000 Idle 0x0001 Command to send written by program in PLC 0x0003 SMS CMGSM 0x0000 SMS sent successfully written by CMGSM 0x0004 Failed while is sending written by SendFlag sending SMS written by CMGSM Local Date and Time NITZ from GSM if available depends on GSM operator DateTime from modem in PLC RTC format refresh approx 1 per 10 sec SendDestAddress Phone number where to send the message Length 20 characters D3801 D3809 ModemTime D3810 D3819 D3820 D3899 SendUserData ext of the characters This range of registers cannot be used for any other purposes message Length 160 FBs CMGSM User s Manual EN v3 07 doc Ho
14. cess code ACODE parameter in configuration and if the access code is valid the message is searched for keywords Only one keyword in every SMS is executed Example of this SMS 11234 INFO 998877 CONFIG FBs CMGSM User s Manual EN v3 07 doc Table of all keywords Keyword INFO STATE Description Device will respond with SMS describing its current status e g CMGSM NETWORK Vodafone CZ 77 IN1 off OUT2 off CSD no connection GPRS no connection PLC connected CMGSM v8 2 Device will respond with confirmation SMS and restart itself PLC is not affected This command is used after change of configuration in PLC register to accept the changes by CMGSM Device will respond with current configuration Current configuration is a default configuration with some values changed by configuration string in PLC see Chapter 5 Configuration RESET FACTORY CMGSM will respond with confirmation SMS CMGSM will write default configuration to attached PLC and restart itself Activate digital output OUT2 Deactivate digital output OUT2 4 4 TCP over GPRS One of the primary functions of this device is to establish and maintain TCP connection from PLC to a server In order to achieve this goal FBs CMGSM has to make following steps after power up Establish connection to PLC via serial port Parameters of the serial port are 9600 baud 7 data bits EVEN parity 1 stop bit no hw handshake it is default FATEK sett
15. ers Caption Description 0x01 connecting Data counter direction not connected D3520 MSB D3520 0x0093 147d D3523 Ox0001 1d Remote IP address if connected 0 0 0 0 connected GPRS diagnostic is part of Diagnostic see chapter Diagnostic Base of Diag Record D3500 may be changed to another D or R register via configuration key REGDIAG 4 5 Events Device can detect special events and send a warning about them as a SMS r Connection to PLC failure restore It is needed to set parameter MASTER in configuration for both of these events see chapter 5 2 Basic Parameters Page 3 of 7 4 6 Diagnostic 5 Configuration Diagnostics values are written to Diagnostic Record standard base D3500 Structure of the record is in following table 5 1 How to Regist Capti D tion SSRS sade cual ds Configuration for CMGSM is located inside PLC Fatek Range of internal PLC registers n no connection to PLC 1 connection to D3900 D3999 is used Configuration itself is a string of characters This string is D3500 0 DiagCnct PLC OK created via WinProladder software from PLC FATEK manufacturer see following O no SMS in receive queue 1 at least one images This range of registers cannot be used for any other purposes DiagRQueue SMS in receive queue result of command AT CREG E WinProLadder Ladder Diagram Main_unit1 O not registered not searching File Edit View Project Ladder PLC Tool Window Help 1 registered
16. es See 4 1 2 Receive a D3700 SMS Only D or R registers can be used Key First register of the Diagnostic Record It is an area where CMGSM writes diagnostic values like operator D3500 signal quality See chapter 4 4 This is a security feature Value zero 0 in this NETRESET parameters means security reset every week 7 days If you do not want any security reset write 1 to this parameter 5 4 GPRS parameters Keys in configuration string Key Description Default ano Access Point for GPRS Ask your GSM provider for this value USER User for APN Mandatory is provider requires Password for APN Mandatory is provider requires Name or IP address of server to which CMGSM will lt empty gt connect TCP connection is used Optional P PORT TCP port for connection Optional 5700 ons IP address of DNS server Optional If SERVER is omitted no GPRS connection is made and device waits for a data CSD 7 2 Simple Use call only 5 5 Examples of Configuration Strings 5 5 1 SIM without PIN Configuration string Translated for human this string says CMGSM3 It is configuration for CMGSM ACODE 998877 Access code for Service SMS Commands is 998877 5 5 2 Use registers D1000 D1100 for sending SMS Configuration string Translated for human this string says CMGSM3 It is configuration for CMGSM PIN 7608 PIN code 7608 for SIM card in order to register into network
17. f remote system analysis and PLC software tuning and modification by WinProladder SW The third way of CMGSM communication over the GSM network is GPRS data connection using TCP IP protocol CMGSM opens the connection in TCP client mode Any SIM card that can provide internet connection over the GSM network can be used CMGSM connects to IP address and port specified in from PLC It is important to notice that the connection can be opened in direction from CMGSM to PC server only PC cannot open a connection to CMGSM because CMGSM has no 3 2 Hardware settings server implemented and usually does not have public IP address GPRS has special data transfer properties data grouping data transfer delay 1 10 seconds which e Switch off the power supply of PLC are not suitable for WinProladder SW WinProladder must use dial up data e Connect GSM antenna transfer so called CSD only Insert SIM card Connect the flat cable between CMGSM and PLC Warning Turn off all power supply during installation of CMGSM to PLC to prevent damage to equipment If a SIM card does not need PIN code no configuration for basic use is necessary For the SIM card with PIN code the configuration in PLC is necessary Read chapter 5 1 Configuration for more Main features e Three ways of GSM network use SMS GPRS Data Call CSD all of 3 3 Startup them practically at the same time WinProladder remote GSM dial up data transfer connection CSD
18. family used with CMGSM It may be TCP imagine as a bidirectional stream of bytes through the Internet and the GSM network from your computer to a Fatek PLC Freva It is a security device It located between you LAN and Internet Main purpose of the Firewall is to protect your LAN against an attack from Internet It is a number of a service in your computer Complete address needed to connect your computer is composed from IP address and Port number and may be seen as 11 22 33 44 5700 IP ADDRESS PORT We recommend this scenario for your first step with CMGSM Your computer in LAN of your company O m Be i You need to prepare following items in this scenario External WAN IP address of your firewall Rest of the Internet sees you with this IP Warning it is NOT your IP address in LAN i e 10 0 0 25 Your external IP address may be obtained from various WEB sites i e http www whatismyip com r A redirection of port 5700 from external side of your firewall to your computer Cooperation of your IT department will be necessary for all of these items We offer simple program that acts like a server CMGSM connects to this server This program is only a demonstration for one connection and elements X0 X3 and Y0 Y3 It may be obtained from our WEB site www seapraha cz Fatek GPRS Server Demo A CO Exit Terminal Connection 8 Waiting For connection Listen on TCP port 5700 Inputs mea ma Ee Outputs O
19. guration 2 Ladder Diagram Table Edit gt ASCI Table Y cig wa Link Table Servo Parameter Table Servo Program Table va General Purpose Link Table Register Table wi ModBus Master Table lt Allow 196 words Auto Used 0 words Output Preview X Cancel Step 3 GPRS Enter configuration string CMGSM3 PIN 7608 APN internet SERVER test server com PORT 5700 ACODE 998877 into field ASCII Editor and click on button Output Overwrite NOR 1 C 1 U 0 F 20223 5 4 Doc U Step 6 Result Preview Warning Change PIN according to your real SIM card Configuration is read after power up and only once If you change configuration for example by WinProladder and second serial port it is not read automatically You Output Preview have to restart CMGSM CMGSM will try to log in the GSM network without PIN if no configuration in PLC is found In this case SIM card without PIN authorization is Select Output Preview Format requested C ASCII Format Output C DAP Format Output For easy understanding this string says CMGSM3 It is a configuration for CMGSM r PIN 7608 PIN code of the SIM card in order to register into the GSM network ACODE 998877 Access code for Service SMS Commands is 998877 MASTER 420777777497 Warning SMS is sent to this phone number in case of any event For example Connection to PLC failure when a oi EE Eal communication between CMGS
20. ings for all serial ports address O1h After power on the FBs CMGSM will proceed steps Read configuration from PLC register D3900 D3999 Login to the GSM network using PIN from configuration Attach to GPRS using APN USER and PASSWD from configuration Establish and maintain TCP connection to SERVER on port PORT CMGSM will try indefinitely to read configuration from PLC at the beginning If there is no serial communication between CMGSM and PLC device will not login into the GSM network If there is no configuration in PLC or the configuration is damaged or other problem occurs CMGSM writes default configuration into the PLC GPRS can be controlled and monitored via set of registers in PLC and via configuration DOWN a GprsLocalPort D3525 D3528 GprsRemoteIP D3529 GprsRemotePort This range of registers cannot be used for any other purposes Basia cprscommana pen connecten omiten by LC 1 open connection written by PLC 0x80 connected D3512 03516 03517 GprsCntUp Data counter direction UP TCP gt PLC D3518 LSB Example D3521 0x0020 32d Local TCP port if connected O if not if not connected D2425 MSB 0x00 no connection idle GprsState 0x81 disconnecting PLC gt TCP D3516 LSB D3518 D3519 GprsCntDown Local IP address if connected 0 0 0 0 if If local IP address is 147 32 80 1 then D3522 0x0050 80d connected Remote TCP port if connected 0 if not Regist
21. mand written by CMGSM tA Fad Langh 32 bit counter which is incremented M Load Table From PLC whenever CMGSM updates DiagRegisters area in PLC The counter is cleared after Description D3508 D3509 DiagUpTime restart of CMGSM The counter value indicates in a certain way how long the CMGSM is running without restart so called Uptime Reserved for GPRS diagnostics P3210 ade See chapter TCP over GPRS for details String with name of operator when X Cancel D3530 D3539 DiagOperator registered Empty string if not registered e 20 characters Step 2 Enter Table Name cfg and Table starting address D3900 D3540 D3549 DiagCredit Reseved o Then click OK Sending AT commands to modem directly Write a command to this place and set 4 ASCII Table cfg D3506 DiagAtFlag to 0x0001 Command 5 ad E D3550 D3699 DiagAtCmd is executed and result is placed in this port Te Export Text E Calculator C Setup S Output Preview place overwriting original command In ASCII Editor D3506 DiagAtFlag is signalized end of CMGSM3 PIN 7608 ACODE 998877 execution The system is the same as with sending SMS D3801 Ox0001 time written to PLC 0x0000 time not written wait for 0x0001 D3500 8 15 DiagGsmReg Allow 196 words Auto Used 0 words D3802 seconds 0 59 purpur ETS view 23 D3803 minutes 0 59 D3804 hours 0 23 D3805 day in month 1 31 D3806 month
22. sions 9 FAQ It s not possible to reset CMGSM using FUNC button it s necessary to hold the button FUNC pressed at least 2 seconds CSD GSM data connection cannot be established 1 check power supply 2 check antenna 3 check indication LED on device and compare it with the manual 3 are CSD connections available on your SIM card Ask provider 4 check GSM signal quality on your mobile phone near the device At least 50 signal is recommended No reply to Service SMS Commands 1 check the power supply 2 check antenna 3 check indication LED on CMGSM and compare to the manual Note LED RCV and SND are not used for Command SMS 4 check configuration is the access code ACODE correct 5 Insert the SIM card from CMGSM to you mobile phone and try to send SMS and receive SMS and voice call Some special characters are not correctly transported by SMS Try to use so called 7 bit SMS 160 characters and only basic ASCII characters 0 127 No communication with PLC 1 check PLC power supply 2 check Port3 FBs xxM or Port1 B1 xxM settings using WinProladder It MUST be 9600 7E1 address 01h 3 Check that no Analog or Communication module is added to WinProladder project Is it possible to use B1 CMGSM simultaneously with Analog or Communication module Not at the moment but we prepare Autodetection In the future B1 CMGSM will connect to PLC through Porti or Port2 depending on usage of Analog or
23. so by SEA customers using GSM applications products made in SEA In spite of making all possible to get error free software it can happen that the software in CPU or PC programming SW or their mutual interaction has some error under some specific conditions If such error is found and the description of the problem including configuration file is sent by E mail to SEA Itd the error is removed free of charge and SEA will send new SW by E mail to customer SEA ltd has NO RESPONSIBILITY for any damage lost costs and any other problems direct or inducted caused by such SW error by eventual device malfunction from any reason or by undelivered SMS from the device sd CE Declaration of conformity in accordance with the Radio and Telecommunications Terminal Equipment Directive 1999 5 EC R amp TTE and Directive 2011 65 EU ROHS We SEA spol s r o Dolnom cholupska 1537 21 CZ 102 00 Praha 10 Czech Republic ID 47117931 manufacturer declare under our sole responsibility that product equipment for remote control and monitoring type FBs CMGSM and B1 CMGSM is in conformity with the following standards Health and safety EN 60 950 1 EMC EN 61000 4 2 3 4 5 6 8 EN 55022 EA sV spol Sro radio frequency EN 301 511 v 9 0 2 An ektronic plikace joinomecholups 7 ive 00 PRAHA 10 Hostiva The last two digits of year in which the CE marking was affixed 14 Hare QO 03 fax 272 701 418 4 197931 ey aera 2 A
24. u Ove Actualization Delay d J is 5s Actualize Now 10s 20s 30s im Details Program listens on TCP port 5700 for incoming connection Port 5700 is default port where CMGSM connects to Program periodically queries status of inputs XO X3 from remote station You can change any of output YO Y3 by click on a check box YO Y1 Page 6 of 7 8 Technical Specifications 8 1 General Parameter Dimensions Fixing Power Unit aoo e o o ee mm ho 2 m mm antenna B1 CMGSM 55 DIN rail or flat panel screw fixing from power supply of PLC main unit Internal Li Ion accumulator for 2 days working without aida PONET ee charging Full capacity will be after 2 day of charging Digital input DC Number f S S r e VoltagelogH Ivin 3 12 30 vx Voltagelogk ivn f lt 4 4 v Gy Polarity current mn TS o DC AC Number gt S S e S Voltage DC VOUToc 8 50 v Digita outputs voltage AC voor Ts fv mA Current DC OUT 0 Current AC OUT 70 Temperature Operational ty 20 45 lec Humidi Antenna connector Communication interface Operational phy 90 ee pow ar aa aar M W lfrequencies uencies Worldwide 850 900 1800 1900 MHz SMA female GSM ANTO5S recommended Flat cable connected directly to PLC FATEK FBs xxMC Port 3 Port 4 B1 xxM Port 1 Port 2 PLC Port is not usable but is not is not accessible for another expan
25. w does the CMGSM send a message START D3800 m WAIT 5s 0x0001 WRITE 0x0003 INTO D3800 READ D3810 D3819 Phone number READ D3820 D3899 Text SENDING WRITE 0x0000 INTO D3800 WRITE 0x0004 INTO D3800 Every register of Phone number or Text contains two characters String of characters ends with special character 0x00 Examples r String with one character A D3820 0x0041 r String TEXT D3820 0x4554 D3821 0x5458 D3822 0x0000 String HELLO D3820 0x4548 D3821 0x4C4C D3822 0x004F If the length of a phone number is exactly 20 characters or 160 characters of text then the character 0x00 at the end is omitted Base of Send Record D3800 may be changed to another D or R register via configuration key REGSEND Only register SendFlag D3800 is changed during sending a message Example of sending a message WE ARE THE CHAMPIONS to phone 123465 Check register D3800 SendFlag for value 0x0000 before sending the message Register Value 0x3231 D3811 0x3433 SendDestAddress characters 3 and 4 D3812 0x3635_ SendDestAddress characters 5 and 6 fpseis_ 0x0000 Endofsting OOOO S SendUserData characters W and E 0x4120 SendUserData characters space and A D3821 D3822 0x4552 SendUserData characters R and E D3823 0x5420 SendUserData characters
26. x4548 D3721 0x4C4C D3722 0x004F If length of phone number is exactly 20 characters or 160 characters of text the character 0x00 at the end is omitted CMGSM contains a queue of up to 100 SMS messages After the queue is full all other SMS messages are discarded If a power failure occurs all received messages in the queue are lost Base of Recv Record D3700 may be changed to another D or R register via configuration key REGRECV No other registers are changed than the necessary ones Example of receiving of message TEST MESSAGE from phone 420123456789 Register VELIT Description RecvOrigAddress characters and 4 RecvOrigAddress characters 3 and 4 0x0039 RecvOrigAddress characters 9 and end of string RecvUserData characters space and M 0x4547 RecvUserData characters G and E 0x002E RecvUserData characters and end of string 4 2 GSM Data Connection Data Call CSD Data connection can be established anytime even if GPRS communication is in progress Warning There is no security mechanism against unauthorized data connection to PLC So it is highly recommended to set security in PLC password 4 3 Service SMS Commands Received SMS message with string and password at the beginning are considered to be service SMS commands These messages are not forwarded to PLC but they are processed in CMGSM Device will check for a valid ac

Download Pdf Manuals

image

Related Search

Related Contents

40370A 1F/I.qxp - Warner Electric  Samsung WF-B105AV Priručnik za korisnike  HMI and Control Loops over Serial Line Communication  Hampton Bay DMQ8012P Installation Guide  Terraillon TPRO6300 User's Manual  CARRO BOMBA FORESTAL JACINTO - MAN  AMX MIO-RCC-KIT  TERMAL - Manual de instalacion.pub    Mode d`emploi 040614 7081992 - 01  