1. OHSAS 18001 GE 1202 ISO9001 ISO14001 Ultrasonic Level Meter USER MANUAL A YITE INSTRUMENT CORP http www ayite net GE 1202 Ultrasonic Level Meter AYITE TECHNOLOGY http www ayite net 1 Overview Sincerely thank you for buying our ultrasonic level meter The GE 1202 meter includes several proprietary technologies is safe and clean with high precision and long service life stable and reliable and convenient to install and maintain and is applicable to various fields of acid alkali salt anticorrosion and high temperature The meter is with following features For circuit design high quality power modules are selected to be as power supply parts and highly stable and reliably imported devices are used as components of the meter It can fully replace imported foreign meters of the same type Patent sonic wave intelligent technology software can make intelligentized echo analysis It needs neither debugging nor other special steps This technology has functions of dynamic thinking and dynamic analysis Our sonic wave intelligent patent technology greatly improves the meter s precision and the precision of liquid level is up to 0 2596 which is enough to resist various interference waves The meter is a non contact one and does not directly contact liquid so the fault rate is low The meter can be installed in several different ways and the user can make meter calibration according to the Manua
2. Explosion proof is avallable too
3. f the transducer launching surface to the highest level is less than the blind area of the purchase instrument is required to install an extension tube that diameter is greater than 200mm and the length is 0 35m 0 50m 3 6 Installation Notes 1 The instrument used outdoors it is best to install awning or the protecting housing so as to avoid the LCD screen ageing affected by sunlight 2 Wire cable protection pipes pay attention to sealing to prevent water and prevent mice and other rodents Bite 3 Although the instrument itself with a lightning protection device but the instrument when used in a multi mine area it is recommended into the outlet end of the instrument to install lightning protection devices dedicated 4 Instruments are used in particularly hot cold places which mean there is likely to exceed the ambient temperature around the instrument s work requirements so we propose increase fortify high and low temperature devices around the liquid level gauge 4 Debugging of meter 4 1 Keyboard directive COM CS 2 SET Press SET about 3 second It will appear 0000 the first 0 is flashing change the first O as 1 then Press OK button enter the parameter setting menu After Finish setting then press SET key to exit the parameter setting menu Al Page up key and number key In menu the key is used as the page up key of menu when changing data the key is used as number key to add number V Page down key In me
4. ht can see whether the height can meet the situation on the ground Can also be used for Calibration of the liquid level In accordance with the situation on the ground to change the value of the probe height You could not change both LEVEL and TH just change one of them 4 3 4 Relay Setting Relay Relay is not standard function It have 4 sign amp N A When change the sign press OK then the sign is flashing then press A and Y to set When finished press SET to exit The meaning of those sign lessthan morethan amp means and need achive both of 2 condition means or just achieve one of the condition GE 1202 Ultrasonic Level Meter AYITE TECHNOLOGY http www ayite net N only the first condition the next will not display N The first condition is for relay close next is for relay open 4 3 5 Display Model DispMode 1 Level the distance between the water surface and bottom 2 AIRH the distance between the water surface to the sensor 3 AIRHT show the AIRH and temperature press A to choose press OK to finish press SET to exit 4 4 7 P Multi Don t change this page it is used for the factory It is produced by A YITE Technology http www ayite net Ultrasonic Level Meter Ultrasonic Depth Meter adopt the ultrasonic principle have perfect function to measure the water depth and the sludge depth the instrument could be custom made for special condition and
5. l The meter s all input and output lines must be with such protection functions as lightning protection and short circuit prevention 2 Technical targets Measuring range 0 15m Chosen based on actual measuring range Blind area 0 25m 0 6m Ranging accuracy 0 25 Standard condition Ranging resolution 1mm Pressure Less than four atmospheric pressure Meter display With LCD to display liquid levels Analog output 4 20mA Digital output RS485 Agreement Modbus or customization agreement Power supply voltage DC24V AC220V lightningproof device installed inside Ambient temperature 20C 60 C Protection grade IP65 GE 1202 Ultrasonic Level Meter AYITE TECHNOLOGY http www ayite net 3 Installation of meter 3 1 Meter s overall size Installation way Open environment commonly used stent installation method using a fixed flange own instrument 3 2 Meter s wiring AC220V 2Um A B SPDTI SPDT2 Power 220V or DC24V Output 4 20mA RS 485 A B Relay 1 SPDTI Relay 2 SPDT2 GE 1202 Ultrasonic Level Meter AYITE TECHNOLOGY http www ayite net 3 3 The meaning of installation parameters Blindarea E L The highest liquid level easuring distance L current liquid level mounting hight TH As shown instrument s transducer sent the wave hit the level then reflected back to transducer the transducer receives by calculate the time then get the val
6. nu the key is used as the page down key of menu when changing data the key is used as used as number key to minus number GE 1202 Ultrasonic Level Meter 5 AYITE TECHNOLOGY http www ayite net OK Confirmation key Choose menu or confirm option and data 4 2 Password directive Press SET key the password interface will appear 0000 press key KA to change the first 0 into 1 and press key OK to enter the interface of parameter setting menu for GE 1201 4 3 parameter set 4 3 1 Level Calibration LEVEL After Meter installed power on The LCD will show the level value but the data are often inconsistent with the actual level so it need level calibration Level calibration steps are as follows press SET about 3 second It will appear 0000 the first O is flashing change the first O as 1 then Press OK button to level calibration with V and Awill be replaced by the actual level value of the number as 2 100 Press SET button to confirm then press SET key to exit the parameter setting menu LCD will display the actual level at this time When calibrate make sure the meter is fixed and no power off 4 3 2 Set 4mA 20mA Press SET about 3 second press W choose menu 20mA it is shall be 20mA level If need change press OK key then press A and Y to set When finished press SET to exit For 4mA the level is 0 unusually be changed 4 3 3 Settings for Probe height TH TH menus can be displayed probe heig
7. ue for L the mounting hight TH subtract the distance L then will be the current level H Meter range means the instrument can measure the distance the installation should be less than a high degree of TH range Instrument blind means measuring instruments in the vicinity of the transducer can not be measured in the region the highest level with the transducer spacing should be greater than the blind for example blind spot for the 0 3m the highest level with the transducer spacing must be greater than 0 3m 3 4 Instrumentation Principles 1 The distance of transducer launching surface to the lowest level should be less than the purchase instrument range 2 The distance of the transducer launching surface to the highest liquid level should be greater than the purchase of the blind instrument 3 The launch surface of the transducer should be keep parallel to the liquid surface 4 Transducer installation location should be as far as possible avoid these liquid surface fluctuations position that just under the inlet outlet if It is impossible to avoid GE 1202 Ultrasonic Level Meter AvITE TECHNOLOGY http www ayite net please install guided wave tube to aid in measuring 5 If the pool wall or tank wall is not smooth meter installation location should at least more than 0 5m from the pool wall or tank wall The specific distance from the pool wall or the tank wall determined according to the actual situation 6 If the distance o

Download Pdf Manuals

image

Related Search

Related Contents

n Wireless Starter Kit n Wireless Router Starter Kit  PikaOne Le Stick MP3 Player  82 CUTMASTER™ Service Manual  User Manual Snapshot  Maple`s manuals  Installation and operating instructions  Matières consommables Intervalles de vidange d  CALIBRE POUR JOINT DE SOUDURE LECTURE DIGITALE  PRIMERGY TX120  EMC Troubleshooting in PC Design  