Home

PDF 1,75 MB

image

Contents

1. e Crosshair tool shows temperature and pixel position resp time at the cursor position e You can modify all plot scales e Fitto screen right click on plot you can fit it to the plot window Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary Yworkswete Scanner e thermal scanner shows the temperature of one line ROI according to time e you can set number of lines of the scanner e you can set temperature range of thermal palette modes manual automatic S Scanner LO Lines 10 Camera settings and information Camera e IP Address network address of your camera device GigE devices only e MAC address unique identifier assigned to network interfaces GigE devices only e Camera manufacturer Camera vendor For WIC device Flir Systems AB e Model camera model WIC 336 AX5 etc e Name user defined camera name WIC cameras name of GigE USB3 module only e USB3 module serial unique identifier assigned to USB3 devices GUID USB3 devices only e Resolution sensor resolution in pixels width x height Communication parameters e Communication control e GigE USB3 related communication parameters and information
2. Changes temperature ranges e High gain from 40 C to 160 C e Low gain from 40 C to 550 C Camera serial 121800 Sensor senal 1089318 Part number 46640007H FPNLX FP 30873342 External sync 5135 3855 e The WIC core provides an external sync channel that can be used to synchronize frame start between two WIC cores one configured as master and the other configured as slave Device informations e Disabled The core relies on internal timing e Master The core relies on internal timing to control its own frame start but also outputs a synchronization pulse on the external sync channel e Slave the core synchronizes its frame start to a pulse aan received on the external sync channel FFC Flat Field Correction e also known as NUC Non Uniformity Correction e Auto Let camera decide when execute based on conditions below e Number of processed frames e Device sensor temperature change e Manual Perform FFC manually e Click on Do FFC button Factory Detaults Reset Camera Test pattern i Save az defaults Calibrate e Off temperature data are transmitted Calorte e Ramp Test image Device setup Offset e Simple calibration e Added to calculated temperatures Restore defaults e Restores default parameters e See table 3 6 in Tau2 IDD document to see full list of affected parameters Reset camera e Performs reset reboot of camera e Device has to be physically reconnec
3. Sequence playback Headquarters Libock 653 51b 16100 Prague Czech republic Welcome image check if you want to open welcome image on startup Thermoimage interpolation check if you want to interpolate thermoimage Layout autosave check if you want to save layout automatically immediately after General Welcome image Thermolmage interpolation Theme Dark Layout autosave v Ximea support v GPS support v Revision 1 4 EN 7 4 2015 All pictures are only for illustration Real values and parameters may vary 4 JWoORKSWELL e Upper camera limit warning shows warning if the measured temperature exceed camera temperature limit e Limit shown framerate e Desired framerate default framerate Application setup General Acquisition j P ot Thermo image Upper camera limit waming Y e Thickness of plot lines time graph thermal Acquisition Limit shown framerate profile limits is Desired framerate ROI Sequence capture e Fonts and label and line colors of ROIs hr e Show min max e Number of lines for thermal scanner e Sequence capture e Predefined file paths for sequence save Application setup e Chunk size if chunk mode is enabled you os have limited maximal size of sequence file Theses wae pee longer sequences will saved in parts Acquisition Chunk mode e Sequence playback ne Chunk size e Live visual playback play visual video Sequence capture Sequence playback
4. When a camera acquires an image it immediately streams those data packets to the host However network firewalls will not allow the packets to reach their destination because firewalls typically block uninitiated incoming traffic Therefore you will need to disable you firewall in order to acquire images from a GigE Vision camera You can disable the Windows Firewall from the Control Panel Start gt gt Control Panel However if you have a network card with an Intel PRO 1000 chipset and you are using the Filter driver that comes with CorePlayer it is most likely that you will not need disable the firewall Notifications and difficulties Jumbo Packets If your NIC device or any intermediate network hardware switch router etc does not support Jumbo packets you will be limited to a packet size of less than 1500 Bytes The GigE Vision packet size cannot be greater than the maximum packet size allowed by the NIC Firewalls Many corporate networks employ firewalls for network security However you cannot acquire from GigE Vision cameras with the firewall enabled unless you use the High Performance driver If your company s network policy does not allow you to disable the firewall or use a different network driver you will need to use a system dedicated to image acquisition that is not part of the corporate network Corrupt XML files As with any new standard camera manufacturing companies routinely release new revision of their firmware
5. e Automatic AGC Presets E mail and Web info workswell cz www workswell cz These presets apply only to the Automatic AGC algorithm and set predefined values that are stored in the GUI for Plateau Value ITT Mean and Max Gain These presets have been empirically determined for different scenarios These settings are intended to be used as guidelines and are not guaranteed to be the optimum values for any particular scenario It is recommended to fine tune settings for preference and scene conditions Revision 1 4 EN 7 4 2015 All pictures are only for illustration Real values and parameters may vary ID Headquarters Reg No 29048575 Libock 653 51b 16100 VAT No CZ29048575 Prague Czech republic YworksweELe M CoreLibrary Overview This library provides basic support of Workswell WIC cameras Because these cameras don t support setup over standard GEV parameters they have to be set via internal serial communication Library with full documentation samples etc is available through CorePlayer gt Menu gt About gt CoreLibrary Documentation or Documents CorePlayer CoreLibrarySRC Characteristics Library is written in both C and C and tested in Windows and supported Linux systems as well Library is based on Pleora eBUS SDK which is bundled to CorePlayer and documented e Start gt Pleora Technologies Inc gt eBUS SDK Requirements e Pleora eBUS SDK 4 0 4 e Visual Studio 201x C version e Visual St
6. together with radiometric sequence e Relative time change time scale to relative or absolute time Help e CoreLibrary documentation links to CoreLibrary documentation e Pan amp Zoom quick help mouse and keyboard Controls for Pan and Zoom control e Changelog list of changes since the last release e About CorePlaver version name of manufacturer link to licenses serial number Phone numbers E mail and Web ID Headquarters REVIRONA EN fat r 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary YworksSweLe Connection Click Connect camera to choose camera device which you want to connect Following dialog will be shown ee eBUS Interface 00 22 4d 7b e1 99 192 168 137 1 Description Roz ifiteln hostitelsk adi Intel R USB 3 0 8 eco274MPGE ac ffc 00 14 07 192 168 137 17 Vendor ID k 086 eBUS Interface b0 48 7a 8a 67fe 192 168 2 9 Device ID x 1631 Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E26 sti L g 2 Super Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E2D Speed Rozsifitelny hostitelsky adi Intel R USB 3 0 goa POR T NTx U3 PT03 PBOUPO1 128 amp U 286701406187 Vendor Name Pleora Technologies Inc Model Name iPORT NTx U3 P TO3 PBOUPO1 128cL Version Versio
7. Activation Server where we would be glad if you took a moment to fill in a brief info about yourself and helped us to improve the software to better suit the needs of our customers After you ll express consent with the Licensing terms and agree to the above terms click Activate and you will be given a unique trial serial number valid for 15 days Your Trial number AS ee ECTS was successfully activated Activated trial serial number Copy the number Then return to the program and click Insert serial number Authentication NOT ACTIVATED Trial version has been requested from Workswell servers and an emai will be sent to provided email address This can take a while After the email has been delivered please Insert serial number Successfull trial serial number request Further steps are the same as if you had a licensed copy of Workswell CorePlayer and are described in next section Full version If vou have a full version of the program or you already have activated trial serial number start the activation process by clicking on Proceed I have a serial number button On the next screen enter your serial number provided by your sales partner or by Workswell and fill in your valid email address Click the Authenticate button Phone numbers E mail and Web ID Headquarters REVISIONS ENa a sa 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are o
8. device Try reconnect your device physically Try reconnect device physically Acquisition error device connected and configured but image cannot be acquired Internal serial port unreachable Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary Yworkswe te Now your camera is connected and you can see currently acquired live thermal image Main menu Live Saved thermo image Therma f camera settings image setup Thermal camera settings ROIs data Camera settings and informations In this menu you can set the camera and image features for most effective image acquisition Thermal camera Disconnect DINO Range U Low 40 160 Source Full Framerate 30Hz Calibration Thermal camera menu for Ax5 cameras Phone numbers E mail and Web ID 420 739 428 433 info workswell cz Reg No 29048575 420 725 955 464 www workswell cz VAT No CZ29048575 Libock 653 51b 16100 Prague Czech republic Thermal camera Disconnect FO u 9 Range U Low 40 160 7 Source Full 7 Framerate OHz Reverse Calibration Analog video Analog pallete WhiteHot 7 Analog palette e Automat
9. may vary 4 JWoORKSWELL S Installing CorePlaver To get vour copy of Workswell CorePlaver go to page www workswell cz CorePlaver eBusChecker First you need to have installed eBus4 SDK 64bit If you don t know which version of this library you have installed you can check it throught the eBusChecker Download it by clicking on eBUSChecker and then open file eBUSChecker exe If you have already correct version of eBus on your computer you can continue by clicking on launch Otherwise click the button Install to install the prerequisites and run the application Setup After clicking on Install the setup exe file will be downloaded Then proceed to the folder where you ve downloaded the setup program and open it If you see a prompt asking whether to install eBUS SDK or not click on Install otherwise the setup program would quit s Configurator Setup The following components will be installed on your machine eBUS4 Do you wish to install these components ff you choose Cancel setup will exit Installation of eBUS SDK Follow the instructions of the eBUS SDK Setup program and in the end if asked reboot your computer The installation will then continue If not please run the setup program again CorePlayer s setup program itself doesn t need any further user interaction and the service application will run immediately as soon as the installation is completed Activation When you run the program f
10. www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary MD WorksweLL e Affects digital output Into Setup Digital Analog setup Thermal AGC Analog video Sensor settings Info Setup Digital Analog e On Off Setup Thermal AGC Pallete WhiteHot Reverse Y Isotherm On Off Video color Color Monochrome sja Frame rate M Upper 95 30Hz 60Hz i Middle 92 Video standard NTSC raat Spot meter Dynamic DDE e Of oF oC Digital Thermometer Analog video Setup Analog video Thermal e Thermal e Palette e Changes color palette e Colors depends on isotherm setup e Isotherm e Portions of the scene exceeding a user selectable threshold are mapped to different portions of the palette e Three user specified thresholds are applicable to the isotherm mode e Specified either in degrees Celsius C or in percentage of full scale e Upper threshold above which pixels will be mapped to the top shades of the palette 224 to 255 e Middle threshold pixels with value between the middle and upper threshold are mapped to shades 176 to 223 e Lower threshold pixels with value between the lower and middle threshold are mapped to shades 128 to 175 e Spot meter e Temperature measurement capability via a spot meter in the central 4x4 area e Accuracy of the spot meter is 20 C in high gain state and the greater of 20 or 20C in low gain state e Can be s
11. 100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary Yworkswe te Reporting Protocol name Date amp time Measure date 02 04 2015 2 4 2015 22 11 i Measure time 22 11 Measured by Part number Measured by Machine number Part number Tool number Material number Note Machine number Tool number Material number Show visible image Logo C Temperature Save report Update Emissivity 0 95 Reflected temperature 20 C Atmospheric temperature 20 C Humidity 5 Distance im Ext optics transmission 1 Temperature range 40 160 C Restore layout restores layout of subwindows to defaults Presentation mode full screen mode with image related controls palette looks best on wide screen display ends full screen mode by clicking deselect Options Presentation mode Options e e e Applicat e e e Phone numbers 420 739 428 433 420 725 955 464 ion setup General e e e Theme Dark only variant J you change it e Ximea support check if you want show Ximea subwindow e GPS support check if you want show GPS subwindow Thermo image e Overview window Acquisition E mail and Web info workswell cz www workswell cz ID Reg No 29048575 VAT No CZ29048575 Application setup General Thermo image Acquisition Plot ROI Sequence capture
12. If you get an error stating that the XML file is corrupt please contact the camera manufacturer for the latest revision of their firmware Interoperability While GenlCam gives camera manufacturers the flexibility of creating a custom attribute set it makes it difficult to easily switch between cameras without modifying your code While the GenlCam Standard Features Naming Convention alleviates this problem to a certain extent most of the conventions are only recommendations and not requirements So a camera manufacturer may deviate from the convention in which case the application software will need to be modified to be interoperable with other eBUS installation While is shown information windows mentioned below there is problem with old version of eBUS SDK For this case you need to remove older version of your eBUS SDK restart PC and launch ThermoConnetor installation again System Update Required EJ i Unable to install or run the application The application requires that assembly PvDotNet Version 4 0 4 3086 be installed in the Global Assembly Cache GAC first More information on this system update can be found by visiting the site here OK Phone numbers E mail and Web ID Headquarters REVIRONA EN fat r 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters
13. User Manual COREPLAYER amp CORELIBRARY 4 gt worKSWELL 4 JWoORKSWELL a General system reguirements Minimal reguirements Processor Intel Core 2 Duo or eguivalent Memory RAM 1 GB HDD At least 100 MB available hard disk space NIC 1000 Mb s Jumbo frame 9kb OS Windows 7 Recommended configuration Processor Intel Core i3 Memory RAM 4 GB HDD 1 GB available hard disk space NIC Gigabit Ethernet adapter and also a Gigabit Ethernet switch could be used for connecting more devices In order to acquire images from a GigE Vision camera you need to first make sure that you have all the correct hardware components and proper configuration Below is a list of requirements Special hardware requirements GigE Vision camera The camera must be GigE Vision standard compliant If you have a camera that has a Gigabit Ethernet port but is not GigE Vision compliant you cannot acquire images using CorePlayer You should find the GigE Vision logo in the camera s user manual or marketing literature Gigabit Ethernet port While it is possible to acquire images with Ethernet and Fast Ethernet ports which support 10 MB s and 100 MB s respectively this will only work at very slow frame rates and small resolutions It is highly recommended that you use a Gigabit Ethernet Network Interface Controller NIC Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info
14. eb ID Headquarters Real values and parameters may vary Reg No 29048575 Libock 653 51b 16100 VAT No CZ29048575 Prague Czech republic Phone numbers 420 739 428 433 info workswell cz 420 725 955 464 www workswell cz 4 JWoORKSWELL EE E Supported Cameras CorePlayer was designed especially for Workswell WIC cameras but there is basic support for other types e Workswell WIC e Fully supported and tested e Configurable device setup with intuitive graphic user interface e Temperature calculation e Flir AxS amp Ax15 e Fully supported and tested e Configurable device setup with intuitive graphic user interface e Temperature calculation Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary Yworkswete Es a CorePlayer software Run application The application will be started immediately after successful installation otherwise you can run it by clicking on desktop icon The following application window will be shown Workswell CorePlayer Source Export Report Options Help Exit Thermal camera Thermo image Visible image Map ROIs 320C Name MAX MIN LIM TP SC Close file Save as h r Thermolmage AVI Record p Filename
15. efficiently transfer data across the network You can enable Jumbo packets in many network cards from the Device Manager by right clicking the network card and selecting Properties Intel R PRO 1000 PT Desktop Adapter Properties Boot Agent Driver Details Resources General Link Advanced Teaming VLANs intel Advanced Adapter Settings Settings Walle n Disabled jumbo Frames 4 au panes 1 Log Link State Event ns A Bytes Performance Options 9014 Bytes Power Saver Options 05 Packet Tagging TCP IP Offloading Options Use Default Jumbo Frames A Enables or disables Jumbo Frame capability In situations where large packets make up the majority of traffic and additional latency can be tolerated Jumbo Frames can reduce CPU utilization and improve wire efficiency Jumbo Frames are larger than standard Ethernet frames which are approximately 1 5k in size Usage Considerations Enable Jumbo Frames only if devices across the network etting Jumbo packets on the Intel PRO 1000 4dapter Phone numbers E mail and Web ID Headquarters REVISION Se ey fat oo 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary YWworKSWELL F Network Firewalls
16. h republic Revision 1 4 EN 7 4 2015 All pictures are only for illustration Real values and parameters may vary 4 OWoORKSWELL Data acguisition See Pleora eBUS manual first to correct setup of PvDisplayThread PvPipeline etc This is not a standalone working code PvDisplayThread DisplayThread new PvDisplayThread set hook to new available frame DisplayThread OnBufferDisplay new OnBufferDisplay OnBufferDisplay private void OnBufferDisplay PvDisplayThread aDisplayThread PvBuffer aBuffer PvImage ImageInfo aBuffer Image uint pixelCount ImageInfo ImageSize 2 14b pixels are mapped to 2 bytes float Temperatures new float pixelCount short RAWData null IntPtr bufferPtr unsafe there are other ways how to do it even without unsafe see eBUS docs bufferPtr new IntPtr ImageInfo DataPointer J if bufferPtr IntPtr Zero Allocate byte array that can contain the copy of data RAWData new short pixelCount Do the copying System Runtime InteropServices Marshal Copy bufferPtr RAWData int pixelCount for int i 9 i lt pixelCount i Temperatures i Raw2Temperatures RAWData i Phone numbers E mail and Web ID Headquarters REVISION Se ey fat oo 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czec
17. h republic Real values and parameters may vary IO WORKSWELL ai Contacts Sales Department Phone 420 725 955 464 ee i Email info workswell cz ddec k lo a Web www workswell cz Ro nov p R ilina Ko ice e B nsk Bystrica Technical Department Phone 420 739 428 433 Email info workswell cz Bratislava Web www workswell cz Headguarters Offices Libock 653 51b Meziricska 100 161 00 Prague 6 756 61 Roznov p R Czech Republic Czech Republic Univerzitn 1 010 08 Zilina Slovakia Phone numbers E mail and Web ID Headguarters Revision 1 4 aa 7 4 oo 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary
18. hown as Digital numeric value and or thermometer style gauge e The numeric indicator and gauge can be shown in degrees Celsius C or Fahrenheit F e The WIC core provides multiple AGC algorithms used to transform 14 bit data to 8 bit e See chapter 3 3 2 6 in Tau2 Product Specification e Not available in isotherm mode Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary 4 JWoORKSWELL e Algorithm Sensor settings e Automatic Info Setup Digital Analog e Automatic parameters Setup Thermal AGC adjustable spoil e Once Bright gare e Contrast adjustable Auto Bright e Auto Bright pan e Contrast Brightness Bias and feed AGC Filter adjustable e Manual pegia e Contrast and Brightness N adjustable e Linear Histogram Automatic Parameters e ITT Mean Max Gain and AGC Filter adjustable Plateau e Contrast ITT Mean e Image contrast Max Gain e Brightness AGC Filter e Image brightness Automatic AGC Presets Default e Brightness bias e Once Bright mode only Camera Communication parameters e Automatic parameters Analog video AGC e Plateau e When plateau value is set high the algorithm approaches the behavior of classic histogram equa
19. ic mode Isotherm Predefined Spot meter Video Standard Thermal camera menu for WIC cameras Revision 1 4 EN 7 4 2015 All pictures are only for illustration Real values and parameters may vary AD WoRKSWELL a x e Start Stop recording button e you can control acquisition of Flir Radiometric video seq file by simple click on this button D e Pause button e when the stream is paused vou can still measure save or export last displayed image e Range C e set the temperature range of camera Low or High for A615 a Middle range is available e Source e select the source of image full sensor size or selected ROI only e Framerate e you can control image acquiring frequency e thermal cameras only e Calibration e Activation of camera shutter e Reverse e you can reverse the image along the X or Y axis e Analog Video for WIC cameras only e Checkbox check if you want to see analog image e Analog palette shows data in selected color scale colors depends on isotherm setup e Analog palette mode you can work in Automatic Isothermal or Predefined mode for more details see Device setup chapter e Spot meter temperature measurement capability via a spot meter in the central 4x4 area e Video standard NTSC or PAL Image setup In this subwindow you can change the image parameters palette and interpolation and the features which are important for correct temperature measureme
20. int click to image to place the point e Line click amp drag to place the line e Polyline click amp drag amp double click to place the broken line e Rectangle click amp drag to place the rectangle e ZOOM tools e every mouse click on the image zoom the image twice e adjustable zoom scale e Fill fill thermo image window with the image e 100 full image size e you can zoom in or zoom out with mouse scrolling too e Thermo image e Image capture right click on the image and you can save the image as Radiometric JPEG PNG or CSV e Radiometric JPEG e native FLIR image format e standard JPEG with radiometric data included e image can be shown in every common image viewer e full radiometric support in FLIR Tools e PNG e lossless data compression e temperature scale inluded thermal cameras only e CSV e comma separated temperature matrix Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary 4 OWoORKSWELL e Palette range vou can adjust image colors by the right sided temperature scale e Automatic mode CorePlaver automatically calculate ideal temperature range e Manual mode vou can set the range manually e S mode Set manual range to o
21. lization gray shades are distributed proportionally to the cumulative histogram and more gray shades will be devoted to large areas of similar temperature in a given scene On the other hand when plateau value is set low the algorithm behaves more like a linear AGC algorithm there is little compression in the resulting 8 bit histogram e ITT Mean e The ITT Midpoint can be used to shift the 8 bit histogram darker or brighter The nominal value is 128 A lower value causes a darker image A darker image can help improve the perceived contrast but it is important to note that more of the displayed image may be railed 8bit value 0 or 255 by moving the midpoint away from 128 e Max Gain e For scenes with high dynamic range that is wide 14 bit histogram the maximum gain parameter has little effect For a very bland scene on the other hand it can significantly affect the contrast of the resulting image e AGC Filter e The IIR filter is used to adjust how quickly the AGC algorithm reacts to a change in scene or parameter value Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary Yworkswe te Phone numbers 420 739 428 433 420 725 955 464
22. n 1 0 Manufacturer Info iPORT NTx U3 P TO3 PBOUPO1 128cU serial Number 01406187 User Defined Name Tau USB3 Configuration Valid True License Valid True GenCP Version 1 0 U3V Version 1 0 Device GUID 288701406187 Family Name Family Name U3V Serial Number 01406187 Low Speed Supported False Full Speed Supported False High Speed Supported True Super Speed Suppor True Speed Super Max Power 96 mA Pleora Driver Installed True Show unreachable Network Devices Device selection Now you see available devices select one and click Ok to perform connection Unreachable camera Sometimes camera has incorrect network setup and it doesn t show up so check the Show unreachable Network devices and your camera should show select it and click Set IP Address and then set correct IP address corresponding to your network configuration Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary YworksweLe s5US5 Interface 00 22 44 7b e1 99 192 168 137 1 ig FLIR AMS 00 11 10 01 19 18 123 123 123 123 EBUS Interface b0 48 7a 8a 67 fe 192 168 2 6 Intel R 7 Series C216 Chipset Family USB Enhanced Host Controller 1E26 Intel R 7 Series C216 Chi
23. nly for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary 4 WORKSWELL A Authentication NOT ACTIVATED Computer ID 6A7FEBFAECF4621FBFF Serial number Email ab workswell ca Inserting serial number Next steps apply for full versions only The Authentication window is now indicating that your serial number is not vet activated Never mind everything has been taken care of NI Authentication NOT ACTIVATED Your serial number is not activated yet Follow the instructions in the email delivered to provided address Then try to authenticate it again Authenticate Before completing the web activation By clicking Authenticate on the previous screen you ve send an activation request to Workswell Activation Server and as a response you will receive email with activation link Click it and fill in a brief info about yourself After you ll express consent with the Licensing terms and conditions by checking the I agree to the above terms click Activate and return to the program Click Authenticate as seen on the image above Authentication NOT ACTIVATED Success You have successfully activated your copy of Workswell ThermoConnector Successful activation Click Run and you are free to use Workswell CorePlayer Revision 1 4 EN 7 4 2015 All pictures are only for illustration E mail and W
24. nt e Palette e shows data in selected color scale e assigned temperatures can be seen on right sided temperature scale e Interpolation e enable disable image pixel interpolation e Emissivity e Very important feature you should set the value depend on measured material range is 0 1 default is 0 95 Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary AD WoRKSWELL e Reflected temperature e Insert ambient temperature to correct reflection of incident radiation e Advanced settings important only for detailed temperature measurement e Atmospheric temperature e Humidity of ambient environment e Distance m of the measured object from camera e Ext optics transmission Live Saved thermo image window You can see the live or opened image or sequence in this window Also you can insert measuring ROI line rectangle point into image zoom the image and adjust temperature range of color palette e ROI Region of Interest tools measuring tools for thermal cameras only e Select ROI vou can resize move selected ROI by dragging on its corner line amp rectangle or ROI itself point e Temperature show current temperature on cursor position e Po
25. or the very first time the Authentication window is the first thing to deal with The Authentication window provides you with two options If you don t have a serial number and want to evaluate the software for a limited period of 15 days choose Request trial version otherwise if you have valid not yet activated serial number click the Proceed have a serial number option a Authentication NOT ACTIVATED jn FS LA 1 TI ji Sar Welcome to Workswell ThemrmoConnector hile to authenticate your software copy After this short r ea wb F ii M ss is completed you are free to use it and we will not bother you Tf you do not own a serial number needed for activation you can request a 15 day trial version Bal Authentication window Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headguarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary 4 JWoORKSWELL 6 s Trial version When reguesting a trial version of Workswell CorePlaver all vou have to do is enter vour valid email address 4 Authentication NOT ACTIVATED Email youremail company con Entering email address In a matter of seconds you will receive an email with activation link leading to Workswell
26. pset Family USB Enhanced Host Controller 1E2D Rozsiritelny hostitelsky adi Intel R USB 3 0 Set IP Address NIC Configuration MAC Address Description MAC IP Address Subnet Mask Default Gateway j 00 774d te 1 99 Subnet Mask IP Address 192 168 137 1 Default Gateway Vendor Subnet Mask Default Gateway GigE Vision Device IP Configuration MAC Address 255 255 255 0 000 0 00 11 1c 01 19 18 Model Access Status Manufacturer Info Version Serial Number User Defined Name Subnet Mask 255 255 Protocol Version IP Configuration License 17 _ 209 0 Default Gateway 0 0 Device Class 0 0 Show unreachable Network Devices Intel R 82579V Gigabit Network Co 00 22 40 7b e 1 99 192 168 137 1 255 255 255 0 0 0 0 0 00 11 1c 01 13 15 255 255 255 0 0 0 0 0 FLIR Systems AB FLIR AX5 Unknown ATAU Gen_A G GEV 1 0 0 GEV 1 5 Version 1 0 02 05 15 62201023 1 2 Invalid on this interface Incorrect network configuration Connection Configuration error In some cases one of following error can occur Try plug off and plug power of you device When the errors persist try reboot your computer In case of USB3 device if errors persist try update your BIOS and or USB3 controller drivers Fr p Configuration error m Acquisition error Device wasn t configured correctly GENERIC_ERROR Status GENCP_INVALID_PARAMETER received from the
27. s e Preconfigured no need to change e Device control e USB3 GigE module device parameters and informations e eg DeviceUserlD User defined name of module e General settings Pixel Format Output Resolution etc e Preconfigured for WIC cameras no need to change e Image stream controlled e Image stream informations e Preconfigured no need to change Sensor settings WIC based devices cannot be currently controlled over standard GenlCam device control parameters so instead you can use following graphic interface on the right side of application Parameters are sorted to several categories Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary YworksweLe e Info e Setup Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary Sensor settings Device informations name type vendor serial numbers etc Info Setup Digital Analog Device Tau 640 Manufacturer FUR Systems Inc Gain mode Via USB3 Resolution 6400512
28. t to affect Revision 1 4 EN 7 4 2015 MD WorksweLL e Digital e You can change type and bit depth of digital output info Setup tal Analog F 14 bit filtered 8 bit None 87 656 CMOS f 14 bitfitered 8 bit Digital video e XB Bus 14bit CMOS is recommended to correct temperature calculation e Analog video e Setup e On Off Analog video e Reverse video e Upside down X Leftside right Y e Affects digital output e Video color e Color Monochrome e Frame rate e doubles framerate 25 50Hz 30 30Hz e Video standard e NTSC PAL e FFC should be executed afterward e Dynamic DDE e digital data enhancement algorithm which can be used to enhance image details and or suppress fixed pattern noise e DDE parameters are computed automatically based on scene contents DDE index which supplants the spatial threshold parameter used in the manual algorithm is the only controlling parameter and ranges from 0 to 63 with higher values representing higher degrees of detail enhancement e Ifno enhancement is desired the value should be set to 17 e Values less than 17 soften the image and filter fixed pattern noise e Values greater than 17 sharpen the details in the image Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464
29. udio NetBeans or any suitable IDE C version Sample use See related documentation Only prerequisition is connected PvDevice object SetDefault method sets both Pleoras videograbber and FLIR Core to correct default parameters Every parameter can be changed by related Property C or Getter Setter C Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary YworksweELe Conection and Setup Example IP address MAC address or GUID of camera PvDevice device PvDevice CreateAndConnect 192 168 1 25 For Tau2 cameras the serial port should be always Bulko CameraSerialSettings settings new CameraSerialSettings mDevice PvDeviceSerial Bulke Sets default settings serial link 14b out Should be called before setting up any parameters above settings SetDefault now we can change parameters settings GainMode GainModes Low execute some action like FFC NUC settings DoFFC or read up something string manufacturer settings Manufacturer Phone numbers E mail and Web ID Headquarters 420 739 428 433 info workswell cz Reg No 29048575 Libocka 653 51b 16100 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czec
30. verall sequence min max for opened seq files only e Play sequence toolbar for opened seq files only OLOO RAs e Start Pause the sequence playback e Previous frame Next frame step over the sequence frames e Cut you can select one part of the sequence time selection and save it as new sequence or remake your previous sequence ROIs list e When you add new ROI it will be shown here with appropriate name and color e You can change the ROI color in the drop down menu e Average maximum and minimum temperature of ROI except point is displayed Enable Time graph display by click on the temperature value min max avg Not available for radiometric JPEG MIN LIM TP SC LIM add temperature limits into the Time graph by checking the LIM checkbox Only available for radiometric sequences TP Enable Thermal profile display by checking TP checkbox SC Enable Thermal scanner display by checking SC checkbox You can delete ROI by clicking on cross button Current ROIs list Plots e Thermal profile for line ROIs only show temperatures of pixels on the line e Time graph for live video and sequences only show min max avg temperature according on time relative or absolute and appropriate limits Thermal profile Time graphs v CrossHair v CrossHair v Relative time S 1 0 1 2 a SL o 20 40 60 20 100 120 140 160 180 Pixel Temperature C boo oh hh k U HH OB Temperature C W
31. workswell cz Reg No 29048575 Libock 653 51b 16100 All pictures are only for illustration 420 725 955 464 www workswell cz VAT No CZ29048575 Prague Czech republic Real values and parameters may vary 4 JWoORKSWELL Network configuration Once vou have the hardware and software installed correctly you must configure the network as well GigE Vision cameras can obtain an IP address from a DHCP server or select one for itself using Link Local Addressing LLA If you connect the camera to a Gigabit Ethernet network with a DHCP server the camera is automatically detected If the camera is connected directly to the computer using either a regular or cross over cable maybe you will need to wait about a minute for the camera to timeout on the DHCP request and use LLA The Windows operating system may display a warning that the network card has only limited operation You can ignore this warning ta ij Local Area Connection 14 s This connection has limited or no connectivity You might not be able to access the Internet or some network resources For more information click this message ATi 11 31 AM Windows displays a warning when camera is directly connected Jumbo packets Typically network drivers will split any data larger than 1500 bytes into multiple packets However the GigE Vision standard allows packet sizes of up to 9014 bytes These large packets also known as Jumbo packets allow the camera to more
32. wwlogoradio jpg Image setup Camera Workswell CorePlayer Capture date 11 02 2015 14 19 Palette Temperature 7 Resolution 640x480 I lati interpolation Thermal profile Time graphs EAEE 095 c v CrossHair v CrossHair wv Relative time Emissivity 0 95 Reflected temp 20 00 C Reflected temperature 20 C Latitude 50 101055 Longitud 14404 Advanced settings ongitude Altitude 10m No line ROI selected No ROI selected Speed Okm h Track 0 Show on map Main application window no camera connected First click Close image to close Workswell welcome thermoimage you can disable the image opening in Application setup menu see below Main menu Source select source of the measured images e Connect Disconnect camera e Open Close file Export export radiometric file or sequence into another format JPEG PNG and CSV e Thermoimage save seq file as Radiometric JPEG PNG or CSV file e Visible image save visible image as PNG file Report you can easy create measurement report e Insert protocol name date and time user name part machine tool material numbers note logo e There are automatically shown thermoimage and time graph emissivity reflected temperature and all advanced image settings e You can save report as PDF file Revision 1 4 EN 7 4 2015 Phone numbers E mail and Web ID Headquarters i 420 739 428 433 info workswell cz Reg No 29048575 Libock 653 51b 16