1. Liebert GXT3 Quick Start Guide 8000 10000VA RT208 Models The Liebert GXT3 is shipped with the following items e Terminal Block Communication terminals e Compact disc with o Liebert MultiLink o Configuration program o User manual electronic version USB cable one 2m 6 1 2 ft long Rack handles with mounting hardware Plastic tower support base one set Plastic Bezel Warnings safety instructions booklet and WEEE recycling sheet ISO 14001 compliance If the installation is in the Tower orientation locate the support base and stand the UPS up on the support base Note the display should be located on the upper half of the unit in the Tower orientation and to rotate the display grasp the sides and rotate it 90 degrees clockwise If the USP is to be installed in a rack enclosure follow the instructions provided with the rack mounting hardware for proper installation Upper Bezel Status Indicators and Controis Lower Bezel and Battery Access Door If using an optional POD that was purchased separately please see instructions shipped with the POD for installation instructions This should be done before connecting the UPS to utility power The UPS is hardwired input with a conduit entry knockouts provided Input and output wiring should be installed in separate conduits All wiring should be done in accordance to all local and national electrical codes Before wiring the UPS ensure that the breaker in the external upst
2. er Indicator Liebert cxT3 Battery Test Button i A Beg System Standby Manual Bypass Button Battery Indicator iy EMERSON 3 SL 23185QS10 RevO 09 2012 Troubleshooting The following symptoms indicate the Liebert GXT3 is malfunctioning e The relative indicators illuminate indicating the UPS has detected a problem e An alarm buzzer sounds alerting the user that the UPS requires attention In addition to the fault indicator being illuminated one or more of LED segments of battery level indicator will also be illuminated to provide a diagnostic aid to the user as shown below A B C The descriptions are listed in the following table Indicator Diagnosis Audiblealarm __ _ _ _ gt Z gt o A___ On bypass due to over temperature condition 1 second beep every 4 seconds Bi On bypass due to DC bus overvoltage 1 second beep every 4 seconds _ C _ On bypass due to DC DC power supply failure 1 second beep every 4 seconds C D C E A amp C mn PFC failure 1 second beep every 4 seconds On bypass due to inverter failure 1 second beep every 4 seconds E A C E A amp B UPS Failure includes dual fan failure single fan failure under certain conditions and battery charger failure and continuous alarm C amp E A amp C CRE UPS shutdown by command from communication USB or Liebert IntelliSlot port no audible alarm AC Input Indicator LED flashing N reverse Battery Indicat
3. he AC Input indicator on the display should illuminate The UPS will also begin to charge the internal batteries at this point so there will also be battery capacity LEDs illuminated The Liebert GXT3 UPS has customizable settings that might be required depending on the application Please review the CD that ships with the UPS unit for the steps to use the configuration program and make any necessary changes Once that is complete proceed to the next step Close all output breakers on the rear of the UPS and on the POD if used or in an external panelboard if used If external battery cabinets are used close all breakers on the rear of each battery cabinet Press and hold for about 4 seconds the ON button on the UPS display Note this will apply power to the output receptacles via the internal bypass and the bypass indicator will be illuminated along with an audible beep Over the next several seconds the UPS will perform the self checks and startup routine then automatically transfer the connected equipment to the inverter power Once that is complete the bypass indicator will turn off and the inverter indicator will illuminate The UPS is now running in normal operation mode providing protected filtered power to the connected equipment On Alam Silence Manual h Battery Level Indicators Load Level Indicators Upper indicator for L1 Lower for L2 Fault Indicator Bypass Indicator AC Input Indicator Invert
4. le provided with the battery cabinet Note it does not matter which connector is used on the battery cabinet If more than one battery cabinet is used the additional cabinets then connect to the adjoining battery cabinet Battery Kit Handle Internal Battery Kit 1 of 2 GXT3 288RTBKIT Output Circuit Breaker Maintenance Liebert GXT3 UPS gt Bypass Breaker GXT3 8000RT208 or GXT3 10000RT208 0 oo oa oD Poe Input Circuit Breaker Optional POD Cover Replace with POD Input Output Conduit Box External Battery Cabinet Connectors for GXT3 288RTVBATT s EMERSON Network Powe 2 SL 23185QS10_Rev0_09 2012 The Liebert GXT3 UPS is ready to be powered ok Ensure the maintenance bypass breaker is in the open position and that the guard is secured in place Ensure that the REPO connecior on the rear of the unit has a jumper between pins 1 2 of the REPO connector or properly wired to an Emergency Power Off circuit normally closed Install any optional Intellislot communication card into the Intellislot port on the rear of the unit Ensure the Power Module locking lever is in the locked position Note this lever is located on the front of the unit just to the left of the display rack orientation or below the display tower orientation Close the input breaker in the panelboard that provides input power to the UPS Close the input breaker on the rear of the UPS unit Note the UPS will now have power and t
5. or Internal battery source not available continuous audible alarm check battery Flashing connection power down and reboot UPS a Utility power voltage or frequency is out of tolerance bypass is unavailable Single Phase UPS amp Server Cabinets Technical Support liebert upstech emerson com 800 222 5877 Outside North America 00800 1155 4499 Emerson Network Power Worldwide Locations United States Europe 1050 Dearborn Drive Via Leonardo Da Vinci 8 P O Box 29186 Zona Industriale Tognana Columbus OH 43229 35028 Piove Di Sacco PD Italy 800 222 5877 39 049 9719 111 Fax 39 049 5841 257 Asia 29 F The Orient Square Building F Ortigas Jr Road Ortigas Center Pasig City 1605 Philippines 63 2 687 6615 Fax 63 2 730 9572 5 EMERSON 4 SL 23185QS10_Rev0_09 2012
6. ream panelboard is OFF Recommended Maximum External Recommended Wire Maximum Wire Over Current All wires Accepted by Terminal Block UPS Model Protection 90 degC Copper Wire Terminal Block Torque GXT3 8000RT208 2 2 GXT3 10000RT208 6 AWG 10mm 4 AWG 16mm 10 in lb Terminal Block Connections OUTPUT INPUT If an optional POD with output receptacles is used connect the equipment to be protected to the output receptacles a EMERSON E 1 SL 23185QS10_Rev0 09 2012 The Liebert GXT3 8000 10000 VA models ship without the internal battery installed Located the internal battery kit model number GXT3 288RTBKIT and follow these steps to install the battery 1 Loosen and remove the screws on the battery door and remove the battery door and set aside the screws and door for reassembly 2 Insert the two battery trays and connect the plugs to the mating receptacles 3 Gently push the battery wiring into the compartment making sure that the wiring will not be pinched when the battery door is reinstalled 4 Reinstall the battery door and secure using the screws that were removed in step 1 5 Locate the plastic bezel from the shipping box and attach the bezel to the UPS taking care to align the fastening clips on both ends before inserting them into the holes 6 If your application requires the use of external battery cabinets for longer back up time requirements connect the first battery cabinet to the UPS with the cab