Home

Blizzard Lighting, LLC www.blizzardlighting.com Waukesha, WI USA

image

Contents

1. gt 055 Mode 0 8 bit 256 dimming steps 056 lt gt 105 Mode 1 32 bit 0 25 intensity range 106 lt gt 155 Mode 2 32 bit 0 50 intensity range 156 lt gt 205 Mode 3 32 bit 0 75 intensity range 206 lt gt 255 Mode 4 32 bit full intensity dimming DMX Values In Depth 7 Channel Mode Value What It Does 000 lt gt 255 Dimmer 0 lt gt 100 000 lt gt 255 Amber Intensity 0 lt gt 100 000 lt gt 255 Warm White Intensity 0 lt gt 100 000 lt gt 255 Cool White Intensity 0 lt gt 100 Strobe 000 lt gt 014 Dimming 015 lt gt 255 Strobe Slow lt gt Fast Page 15 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC DMX Values In Depth 7 Channel Mode Continued Fade Color Change Sound Active 000 lt gt 031 No Function 032 lt gt 063 Fade In Ch 5 Controls Speed 064 lt gt 095 Fade Out Ch 5 Controls Speed 096 lt gt 127 Fade In Fade Out Ch 5 Controls Speed 128 lt gt 159 ACW Gradual Change Ch 5 Controls Speed 160 lt gt 191 Fade In Fade Out Auto Run 192 lt gt 223 Color Jump Ch 5 Controls Speed 224 lt gt 255 Sound Active Color Saturation 000 lt gt 009 Invalid Ch 1 Controls 010 lt gt 029 A 100 Saturation 030 lt gt 039 A85 A C 15 040 lt gt 049 A60 A C 40 050 lt gt 069 A C 100 070 lt gt 079 A C 85 C15 080 lt gt 089 A C 60 C4
2. ROMBO INFINIWHI TE wi IC Ce LIGHTING Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2013 TABLE OF CONTENTS RokBox Infiniwhite p 1 Getting Started w What s In The Box Getting It Out Of The Box Powering Up Getting A Hold Of Us Safety Instructions Don t Stick Your Hand In The Toaster 2 Meet The RokBox Infiniwhite Features DMX Quick Reference The RokBox Infiniwhite Pin up Picture 3 Setup Fuse Replacement Connecting A Bunch Of RokBox Infiniwhite PAR Cans Data DMX Cables Cable Connectors 3 Pin 5 Pin Huh Take It To The Next Level Setting up DMX Control Fixture Linking Master Slave Mode Mounting Rigging Using this fixture with the wiCICLE Wireless DMX System 10 O O 00 0 NNN N uun YU SWWWW 4 Operating Adjustments 12 Navigating The Control Panel 12 Control Panel Menu Structure 13 DMX Mode 14 Master Slave Mode 14 Sound Active Mode 14 Standalone Program Mode 14 Manual Color Adjustment 14 DMX Channel Values In Depth 15 Troubleshooting 17 5 Appendix 18 A Quick DMX Lesson 18 Keeping Your RokBox Infiniwhite As Good As New 19 Returns Gasp 19 Shipping Issues 19 Tech Specs 20 Page 2 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC 1 GETTING STARTED What s In The Box e 1 x RokBox Infiniwhite Professional LED PAR Fixture e A totally rockin DMX Cable e An awesome PowerCon Compatible
3. 5 APPENDIX A Quick Lesson On DMX DMX aka DMX 512 was created in 1986 by the United States Institute for Theatre Technology USITT as a standardized method for connecting lighting consoles to lighting dimmer modules It was revised in 1990 and again in 2000 to allow more flexibility The Entertainment Services and Technology Association ESTA has since assumed control over the DMX512 standard It has also been approved and recognized for ANSI standard clas sification DMX covers and is an abbreviation for Digital Multiplexed signals It is the most common communications standard used by lighting and related stage equipment DMX provides up to 512 control channels per data link Each of these channels was origi nally intended to control lamp dimmer levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 The value 0 corresponds to the light bulb being completely off while 255 corresponds to the light bulb being fully on DMX data is transmitted at 250 000 bits per second using the RS 485 transmission stan dard over two wires As with microphone cables a grounded cable shield is used to prevent interference with other signals There are five pins on a DMX connector a wire for ground cable shield two wires for Primary communication which goes from a DMX source to a DMX receiver an
4. DAMAGE FROM SUCH OPERATION e Fixtures bearing the above logo MUST only use cable and connec tors which separate chassis case ground from cable shielding Cabling with the shield connected to the connector s case chassis may cause malfunction and damage to the wiCICLE or fixture e wiCICLE transmitters have additional power requirements and therefore cannot be powered directly from the fixture You will need to utilize the supplied AC DC adaptor to drive wiCI CLE transmitters in your system WE HAD THIS SPACE SO WE FIGURED WE D DRAW YOU A PICTURE Antenna Housing amp 1 2 wave Antenna Antenna ferrule amp articulation joint Stainless Steel Housing Recessed Selector Button Status LED 3 Pin XLR Connector Male on transmitter Female on receiver model Page 10 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Each wiCICLE acts as both a transmitter and a receiver depending on whether a DMX source is applied to the integral XLR connector This is an extremely powerful feature of the system however it also requires 1 piece of due dili gence and that is the removal of extraneous DMX signals from your lighting rig BEFORE proceeding SO BEFORE DOING ANYTHING ELSE YOU SHOULD DISABLE ANY BUILT IN PROGRAMS IN THE FIXTURES YOU WISH TO CONNECT AND OR SET THEM AS SLAVES PRIOR TO RETURNING THEM TO DMX MODE IF APPLICABLE Most fixtures contain a built in automatic soun
5. lt gt 100 Sound active mode Display menu on off Dimming mode 0 4 Software version Page 13 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC DMX Mode Allows the unit to be controlled by any universal DMX controller MUTI 1 The default mode for the fixture is DMX which appears as duu fon the LED Readout To select a different DMX address using the lt MENU gt button select Feder then hit lt ENTER gt Use the lt UP DOWN gt buttons to select the correct address then hit lt ENTER gt to confirm Setting the DMX Channel Mode 1 To select a DMX channel mode press the lt MENU gt button then use the lt UP gt or g j lt DOWN gt buttons until the display reads Lined and press the lt MENU gt button Then use the lt UP gt or lt DOWN gt buttons until the display reaches your desired channel mode Press the lt MENU gt button to confirm Stand Alone Master Slave Sound Active Modes Allows a single or Master Slaved units to run factory installed programs at user selectable speeds CI COLI 1 To set the fixture in Flash Fade mode select FL AS or FAROE To confirm press the lt ENTER gt button gt gt El Moi 10 2 Now you can adjust the flash settings from IL LILITITL 123 or the fade settings from FAOC FR 15 i LILI 123 Then press the lt ENTER gt button to confirm cr 3 To use the fixture in automatic mode select ASC and press the lt ENTER gt button Then Moo
6. than that stated on the de cal or rear panel of the fixture e This product is intended for indoor use only e To prevent risk of fire or shock do not expose fixture to rain or moisture e Make sure there are no flammable materials close to the unit while operating e The unit must be installed in a location with adequate ventilation at least 20in 50cm from adjacent surfaces Be sure that no ventilation slots are blocked e ALWAYS disconnect from the power source before servicing or replacing fuse and be sure to replace with same fuse size and type e ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles e DO NOT operate at ambient temperatures higher than 104 F 40 C e In the event of a serious operating problem stop using the unit immediately NEVER try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized tech nical assistance center Always use the same type spare parts e NEVER connect the device to a dimmer pack e Make sure the power cord is never crimped or damaged e Never disconnect the power cord by pulling or tugging on the cord e Avoid direct eye exposure to the light source while it is on Caution There are no user serviceable parts inside the unit Do not open the housing or attempt any repairs yourself In the unlikely event your unit may require service please c
7. 0 090 lt gt 109 C 100 110 lt gt 119 C85 W15 120 lt gt 129 C60 W40 130 lt gt 149 W 100 150 lt gt 159 W85 C W 15 160 lt gt 169 W60 C W 40 170 lt gt 189 C W 100 190 lt gt 199 C W 50 A W 50 200 lt gt 219 A W 100 220 lt gt 229 A W 50 A C W 50 230 lt gt 249 A C W 95 A C 5 250 lt gt 255 All Colors on 100 DMX Values In Depth 6 Channel Mode 000 lt gt 255 Dimmer 0 lt gt 100 Amber Intensity 0 lt gt 100 5 Strobe 000 lt gt 014 Dimming 000 lt gt 255 Strobe Slow lt gt Fast Fade Color Change Sound Active 000 lt gt 031 No Function 032 lt gt 063 Fade In Ch 5 Controls Speed 064 lt gt 095 Fade Out Ch 5 Controls Speed 096 lt gt 127 Fade In Fade Out Ch 5 Controls Speed 128 lt gt 164 ACW Gradual Change Ch 5 Controls Speed 165 lt gt 191 Fade In Fade Out Auto Run 192 lt gt 223 Color Jump Ch 5 Controls Speed 224 lt gt 255 Sound Active Page 16 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC DMX Values In Depth 3 Channel ACW Mode ch Value wnat It Does 3 Ch Amber Intensity 0 lt gt 100 000 lt gt 255 Warm White Intensity 0 lt gt 100 000 lt gt 255 Cool White Intensity 0 lt gt 100 Troubleshooting Fixture Auto Shut Check the fan in the fixture If it is stopped or Off m
8. D Display shows the menu items you select from the menu map on page 11 When a menu function is selected the display will show immediately the first available option for the selected menu function To select a menu item press lt ENTER gt Press the lt MENU gt button repeatedly until you reach the desired menu function Use the lt UP gt and lt DOWN gt buttons to navigate the menu options Press the lt ENTER gt button to select the menu function currently displayed or to enable a menu option To return to the previ ous option or menu without changing the value press the lt MENU gt button Page 12 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Control Panel Menu Structure Addr gt od I oS id SAU gt SAU LHnd BLH W BLH JLH SP gt 5Po0 SP15 Pr gt rad Pr 15 ASL gt ACO AC FAJE gt FADO FA IS FLAS gt LOG FL IS rl OE 255 5L gt 6000 6255 bL gt sb 255 Sou gt Souf LEJ gt o0n oFF node gt nadtl nad t vt gt moon ULI UELO To choose the DMX address To run the fixture in slave mode 8 channel DMX mode 7 channel DMX mode 6 channel DMX mode 3 channel DMX mode Speed adjustments 0 15 Built in programs 0 15 Auto mode 0 15 Fade settings 0 15 Flash strobe speed 0 15 Amber dimmer 0 lt gt 100 Warm White dimmer 0 lt gt 100 Cool White dimmer 0
9. Power Cord e This Lovely User Manual Getting It Out Of The Box Congratulations on purchasing one of the most rocking box shaped PAR fixtures any where Now that you ve got your RokBox Infiniwhite or hopefully RokBoxes you should carefully unpack the box and check the contents to ensure that all parts are present and in good condition If anything looks as if it has been damaged in transit notify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and pack ing Powering Up All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify that the fixture you receive is suitable for your local power supply See the label on the fixture or refer to the fixture s specifications chart for more information A fixture s listed current rating is its average current draw under normal conditions Check the fixture or device carefully to make sure that if a voltage selection switch exists that it is set to the correct line voltage you will use Warning Verify that the voltage select switch on your unit matches the line vo
10. This is a great feature of DMX if for some reason the data is not interpreted the first time around it will be re sent shortly Not all 512 channels need to be output per packet and in fact it is very uncommon to find all 512 used The fewer channels are used the higher the refresh rate It is possible to get DMX refreshes at around 1000 times per second if only 24 channels are being trans mitted If all 512 channels are being transmitted the refresh rate is around 44 times per second In summary since its design and evolution in the 1980 s DMX has become the standard for lighting control It is flexible robust and scalable and its ability to control everything from dimmer packs to moving lights to foggers to lasers makes it an indispensable tool for any lighting designer or lighting performer Page 18 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Keeping Your RokBox Infiniwhite As Good As New The fixture you ve received is a rugged tough piece of pro lighting equip ment and as long as you take care of it it will take care of you That said like anything you ll need to take care of it if you want it to operate as designed You should absolutely keep the fixture clean especially if you are using it in an environment with a lot of dust fog haze wild animals wild teenagers or spilled drinks Cleaning the optics routinely with a suitable glass cleaner will greatly improve the quality of lig
11. an connecting the lowest fixture number first and so on Step 3 Connect other fixtures in the chain from output to input as above Place a DMX terminator on the output of the final fixture to ensure best communication DMX IN DMX OUT To Next Fixture Page 8 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Fixture Linking Master Slave Mode 1 Connect the male 3 pin connector side of the DMX cable to the output female 3 pin connector of the first fixture 2 Connect the end of the cable coming from the first fixture which will have a female 3 pin connec tor to the input connector of the next fixture con sisting of a male 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on A quick note Often the setup for Master Slave and Standalone operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or DIP switches Secondarily the fixtures that follow may also re quire a slave setting First Fixture in Chain DMX IN Next Fixture in Chain To Next Fixture DMX IN DMX OUT Check the Operating Adjustments section in this manual for com plete instructions for this type of setup and configuration Mounting amp Rigging This fixture may be mounted in any SAFE position provided there is enough room for ventilation It is important never t
12. bility with products manufactured by Neutrik AG Neutrik USA and their related entities howev er they are not manufactured by affiliated with or endorsed by Neutrik AG Neutrik USA or any related entity Neutrik and powerCON are registered trademarks of Neutrik AG Page 20 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC This page left intentionally blank Page 21 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC This page left intentionally blank Page 22 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC This page left intentionally blank Page 23 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting
13. channel group 5 Once both the transmitter and receiver s are both set to the same chan nel group connect the transmitter to the DMX controller or the DMX out of a fixture on your DMX chain 6 Once a DMX signal is provided to the transmitter the status LED will blink RED slowly until communication is established with the receiver The status LED on the receiver s will flash GREEN slowly until communication is estab lished 7 Once the clearest channel is auto selected the status LEDs will blink quickly on both the transmitter and receiver NOTE The color of the LED DURING operation does not indicate channel group instead it indicates whether the unit is transmitting or receiving That s It Page 11 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC 4 OPERATING ADJUSTMENTS The Control Panel All the goodies and different modes possible with the RokBox Infini white LED are accessed by using the control panel on the rear of the fixture There are 4 control buttons below the LED display which allow you to navigate through the various control panel menus lt MENU gt Is used to navigate to the previous higher level menu item lt UP gt Scrolls through menu items and numbers in ascending order lt DOWN gt Scrolls through menu items and numbers in descending order lt ENTER gt Is used to select and confirm store the current selection O O MENU DOWN ENTER The Control Panel LE
14. connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal The maximum recommended cable run distance is 500 meters 1640 ft The maximum recommended number of fixtures on a serial data link is 32 fixtures Data DMX Cabling To link fixtures together you ll need data cables You should use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference For instance Belden 9841 meets the specifications for EIA RS 485 applications Standard microphone cables will probably be OK but note that they cannot transmit DMX data as reliably over long distanc es In any event the cable should have the following characteristics 2 conductor twisted pair plus a shield Maximum capacitance between conductors 30 pF ft Maximum capacitance between conductor amp shield 55 pF ft Maximum resistance of 20 ohms 1000 ft Nominal impedance 100 140 ohms Page 7 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Cable Connectors Cables must have a male XLR connector on one end and a female XLR connector on the other end Duh A Word on Termination DMX is a resilient communication protocol however errors still occasionally occur Termination reduces signal errors and therefore best practices include use of a terminator in all circumstances If you are experiencing prob
15. d active or custom program which is designed to operate with the fixture NOT connected to a DMX chain Some of these programs will automatically run unless the fixture is set to slave mode These fixtures typically sense DMX automatically and switch to DMX mode upon receiving DMX signal our Pucks do that If you plug a wiCICLE receiver into an autosensing fixture set as a mas ter chances are good that the wiCICLE receiver will begin transmitting the master program Most times this is undesirable and taking the two seconds to switch these programs off will solve a lot of ails Got that done Good Then let s proceed 1 Plug the wiCICLE Receiver into the DMX IN connector of the fixture and verify it is receiving power the STATUS LED should illuminate 2 Connect the AC DC adaptor to the wiCICLE Transmitter and verify it is re ceiving power the STATUS LED should illuminate 3 Press the RECESSED SELECTOR BUTTON on the Transmitter to select the operating channel group The system will store this setting for future use The 7 Color Status LED will change color to indicate the current channel group GROUP 1 RED GROUP 2 GREEN GROUP 3 YELLOW NOTE GROUP number GROUP 4 BLUE also corresponds to the GROUP setting on our GROUP 5 FRE LightCaster wireless DMX GROUP 6 CYAN Transceiver GROUP 7 WHITE 4 Follow the same procedure on the Receiver to select the
16. d Lighting LLC Figure 1 The RokBox Infiniwhite Pin Up Picture High Power 3 in 1 Heavy Duty Cast ACW LEDs Aluminum Enclosure Dual Mounting Yokes amp Adjustment Locking Knobs Figure 2 The Rear Connections DMX Out LED Display DMX In CoE OOo f 3 MX OUT i DO dd i TOWER Our uo ue com enn at ors AC Power Out Menu Buttons AC Power In Page 6 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC 3 SETUP Before replacing a fuse disconnect power cord ALWAYS replace with the same type and rating of fuse Fuse Replacement CAUTION The RokBox Infiniwhite utilizes a high output switch mode power supply with an internal fuse Under normal operating conditions the fuse should not require replacement The fuse is field replaceable however it is an advanced procedure suited to qualified individuals Should your RokBox Infiniwhite fuse require replace ment please contact Blizzard Lighting for instructions or to return your unit for service Connecting A Bunch of RokBox Infiniwhite Fixtures You will need a serial data link to run light shows using a DMX 512 controller or to run shows on two or more fixtures set to sync in mas ter slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fix tures the data link can support Fixtures on a serial data link must be daisy chained in one single line Also
17. d i use the lt UP DOWN gt to choose from FISCO AS 15 then press the lt ENTER gt button to confirm I mw 4 Adjust the speed of the chase as above using GP 15 slowest to Pog fastest then press the lt ENTER gt button to confirm Ii 5 To set the fixture as a slave unit select SL AL and hit lt ENTER gt The unit will display a I i flashing SLAJ to indicate it is in slave mode Sound Active Mode 1 To use sound active mode select Souf then press the lt ENTER gt button to confirm Standalone Program Mode Allows a single unit to display a variety of colors and programs without a DMX controller 1 To set the fixture in manual mode select P To confirm press the lt ENTER gt button mw 2 Now select the program by using the lt UP gt and lt DOWN gt buttons to select Pag I Pr 5 To confirm press the lt ENTER gt button Manual Color Adjustment Allows the user to adjust the color balance of the fixture These settings are global they will effect all modes 1 TI a 1 Use the lt MENU gt and lt UP DOWN gt button to select L Amber Level LIL Warm 1 White Level bi Cool White Level then hit lt ENTER gt 2 Using the lt UP DOWN gt buttons select the maximum level for each color between Muri CE XIILILI x 055 000 off then hit lt ENTER gt to confirm Page 14 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC DMX Values In Depth 8 Channel Mode What It Do
18. d two wires for a Secondary communication which goes from a DMX receiver back to a DMX source Generally the Secondary channel is not used so data flows only from sources to receiv ers Hence most of us are most familiar with DMX 512 as being employer over typical 3 pin mic cables although this does not conform to the defined standard DMX is connected using a daisy chain configuration where the source connects to the input of the first device the output of the first device connects to the input of the next device and so on The standard allows for up to 32 devices on a single DMX link Each receiving device typically has a means for setting the starting channel number that it will respond to For example if two 6 channel fixtures are used the first fixture might be set to start at channel 1 so it would respond to DMX channels 1 through 6 and the next fixture would be set to start at channel 7 so it would respond to channels 7 through 12 The greatest strength of the DMX communications protocol is that it is very simple and robust It involves transmitting a reset condition indicating the start of a new packet a start code and up to 512 bytes of data Data packets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing i e no lamp levels change the same data will be sent out over and over again
19. es 000 lt gt 255 Dimmer 0 lt gt 100 000 lt gt 255 Amber Intensity 0 lt gt 100 000 lt gt 255 Warm White Intensity 0 lt gt 100 000 lt gt 255 Cool White Intensity 0 lt gt 100 Strobe 000 lt gt 014 Dimming 015 lt gt 255 Strobe Slow lt gt Fast Fade Color Change Sound Active 000 lt gt 031 No Function 032 lt gt 063 Fade In Ch 5 Controls Speed 064 lt gt 095 Fade Out Ch 5 Controls Speed 096 lt gt 127 Fade In Fade Out Ch 5 Controls Speed 128 lt gt 159 ACW Gradual Change Ch 5 Controls Speed 160 lt gt 191 Fade In Fade Out Auto Run 192 lt gt 223 Color Jump Ch 5 Controls Speed 224 lt gt 255 Sound Active Color Saturation 000 lt gt 009 Invalid Ch 1 Controls 010 lt gt 029 A 100 Saturation 030 lt gt 039 A85 A C 15 040 lt gt 049 A60 A C 40 050 lt gt 069 A C 100 070 lt gt 079 A C 85 C15 080 lt gt 089 A C 60 C40 090 lt gt 109 C 100 110 lt gt 119 C85 W15 120 lt gt 129 C60 W40 130 lt gt 149 W 100 150 lt gt 159 W85 C W 15 160 lt gt 169 W60 C W 40 170 lt gt 189 C W 100 190 lt gt 199 C W 50 A W 50 200 lt gt 219 A W 100 220 lt gt 229 A W 50 A C W 50 230 lt gt 249 A C W 95 A C 5 250 lt gt 255 AII Colors on 100 32 Bit Dimmer 000 lt gt 005 As set in the control menu display 006 lt
20. for shipping When returning your fixture for service be sure to include the following 1 Your contact information Name Address Phone Number Email address 2 The RA issued to you 3 A brief description of the problem symptoms We will at our discretion repair or replace the fixture Please remember that any shipping damage which occurs in transit to us is the customer s responsibil ity so pack it well Shipping Issues Damage incurred in shipping is the responsibility of the shipper and must be reported to the carrier immediately upon receipt of the items Claims must be made within seven 7 days of receipt Page 19 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC Tech Specs Width Weight Operating Voltage 100 264VAC 47 63 Hertz Fuse 3A 250V Power Consumption 90W Light Source LED 18x 5W 3 in 1 LEDs 100 000 hours Beam Angle 25 degree optics standard 25 degree beam 45 degree field Thermal Max Operating Temp 104 degrees F 40 degrees C ambient Protocol USITT DMX 512 DMX Channels 3 6 7 8 Input 3 pin XLR Male Output 3 pin XLR Female Standalone Master Slave Sound Active Color Other Operating Modes Preset I always wanted to play in a band Maybe like Chicago One can dream right 2 year limited warranty does not cover mal Warranty function caused by damage to LED s DISCLAIMER The power connector fitted to the fixture and fixture cord are designed for compati
21. ht output Keeping the fans free of dust and debris will keep the fixture running cool and prevent damage from overheating In transit keep the fixtures in cases You wouldn t throw a prized guitar drumset or other piece of expensive gear into a gear trailer without a case and similarly you shouldn t even think about doing it with your shiny new light fixtures Common sense and taking care of your fixtures will be the single biggest thing you can do to keep them running at peak performance and let you worry about designing a great light show putting on a great concert or maximizing your cli ent s satisfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sending a unit in for service But like any complex piece of equipment designed and built by humans once in a while something doesn t go as planned If you find yourself with a fixture that isn t behaving like a good little fixture should you ll need to obtain a Return Authori zation RA Don t worry this is easy Just send an email to support blizzardlighting com and we ll issue you an RA Then you ll need to send the unit to us using a trackable pre paid freight method We suggest using USPS Priority or UPS Make sure you carefully pack the fixture for transit and whenever possible use the original box amp packing
22. lems with erratic fixture behavior especially over long signal cable runs a terminator may help improve performance To build your own DMX Terminator Obtain a 120 ohm 1 4 watt resistor and wire it between pins 2 amp 3 of the e 3 120 ohm 1 4 watt resistor last fixture They are also readily O s available from specialty retailers CAUTION Do not allow contact between the common and the fix ture s chassis ground Grounding the common can cause a ground loop and your fixture may perform erratically Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other 3 Pin 5 Pin Huh If you use a controller with a 5 pin DMX output connector you will need to use a 5 pin to 3 pin adapter They are widely available over the internet and from specialty retailers If you d like to build your own the chart below details a proper cable conversion 3 Pin Female 5 Pin Male Output Input Ground Shield DMX Data 3 Tn Take It To The Next Level Setting Up DMX Control Step 1 Connect the male connector of the DMX cable to the female connector output on the controller Step 2 Connect the female connector of the DMX cable to the first fixture s male connec tor input Note It doesn t matter which fixture address is the first one connected We recommend connecting the fixtures in terms of their proximity to the controller rather th
23. ltage applied Damage to your fixture may result if the line voltage applied does not match the voltage indicated on the voltage selector switch All fixtures must be connected to circuits with a suitable Ground Earthing Getting A Hold Of Us If something is wrong just give us a call or send an email We ll be happy to help honest Blizzard Lighting N16 W23390 Stoneridge Dr Suite E Waukesha WI 53188 USA www blizzardlighting com 414 395 8365 Email support blizzardlighting com Disclaimer The information and specifications contained in this document are subject to change without notice Blizzard Lighting assumes no responsibility or liability for any errors or omissions that may appear in this user manual Blizzard Lighting reserves the right to update the existing document or to create a new document to correct any errors or omissions at any time You can download the latest version of this document from www blizzardlighting com Page 3 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC SAFETY INSTRUCTIONS Please read these instructions carefully They include important information about the installation usage and maintenance of this product e Please keep this User Guide for future use If you sell the unit to someone else be sure that they also receive this User Guide e ALWAYS make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher
24. o obstruct the fan or vents pathway Mount the fixture using a suitable C or O type clamp The clamp should be rated to hold at least 10x the fixture s weight to ensure structural sta bility Do not mount to surfaces with unknown strength and ensure properly rated rigging is used when mounting fixutres overhead Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding the desired position retighten both knobs e When selecting installation location take into consideration lamp replacement access if applicable and routine maintenance e Safety cables MUST ALWAYS be used e Never mount in places where the fixture will be exposed to rain high humidity extreme temperature changes or restricted ventilation Page 9 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC USING THIS FIXTURE WITH THE wiCICLE WIRELESS DMX SYSTEM In addition to the unbridled thrill you al o ready received the first time you plugged wil C C in your fixture you ll be delighted to know that This fixture also works seamlessly with our wiCICLE Wireless DMX system without additional power e ONLY fixtures bearing this logo are certified for use with the wiCI CLE without external power e Unauthorized modification and or using the wiCICLE with unapproved fixtures may cause damage to the wiCICLE or fixture UNDER NO CIRCUMSTANCES IS BLIZZARD LIGHTING RESPONSIBLE FOR ANY
25. ontact Blizzard Lighting at sup port blizzardlighting com Page 4 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC 2 MEET THE ROKBOX INFINIWHITE LED PAR CONTROL FEATURES e ACW color mixing via 18x 5W Amber Cool White Warm White 3 in 1 LEDs e Variable electronic dimming amp strobe e Built in color amp chase macros via DMX e Built in automated programs via master slave e Built in sound active programs e ACW color mixing ability in standalone mode e 3 Ch 5 Ch 6 Ch and 8 Ch DMX Profiles ADDITIONAL FEATURES e Rugged and well built It hits the gym regularly e Super quiet variable speed internal Fan Cooling e Dual mounting brackets for positioning flexibility e Flicker free constant current 400hz LED driver e 3 pin male input and 3 pin female output e PowerCon compatible AC power In Out connectors DMX Quick Reference 7 8 Channel Mode channel 7 channet s chann Dimmer omme 3 warm White intensity Warm White Intensity a Cool white intensity Cool White Intensity Built In Programs Built In Programs 7 ACW Gradual Mixing ACW Gradual Mixing 32 Bit Dimmer Set by Display on fixture 0 4 DMX Quick Reference 3 Channel ACW 6 Channel Mode Channel 3 Channel ACW 5 Channel Amber Intensity Warm White Intensity Amber Intensity Coo White Intensity Strobe Built In Programs i i te Intens Page 5 RokBox Infiniwhite Manual Rev A 2014 Blizzar
26. oving slower than normal the unit may have shut itself off due to high heat This is to pro tect the fixture from overheating Clear the fan of obstructions or return the unit for service Beam is Dim Check optical system and clean excess dust grime Also ensure that the 220V 110V switch is in the correct position if applicable No Light Output Check to ensure fixture is operating under cor rect mode IE sound active auto DMX Etc if applicable Chase Speed Too Check to ensure proper setup of speed adjust Fast Slow ment No Power Check fuse AC cord and circuit for malfunction Blown Fuse Check AC cord and circuit for damage verify that moving parts are not restricted and that unit s ventilation is not obstructed Slow Movement Verify that 220V 110V switch is in the correct position if applicable Also check that speed channels are set appropriately No Response to Verify that the fixture is in Sound Active mode Audio Adjust Audio Sensitivity If Applicable Fixture Not Make sure all connectors are seated properly Responding and securely Responding Use Only DMX Cables and or check cables for Erraticly defects Install a Terminator Reset fixture s Fixture Moving On Verify proper mode of operation Is the fixture Its Own in Auto mode If your problem persists or isn t listed contact support blizzardlighting com Page 17 RokBox Infiniwhite Manual Rev A 2014 Blizzard Lighting LLC